12
RFX No. 4000045400 - SC 1000010333 Dismantling & Shifting of Aviation Light Warning System from 17- Towers of Qassim Area & Supply & Installation of New Aviation Light Warning System on All 17- Towers

Obstraction light syatem

Embed Size (px)

Citation preview

Page 1: Obstraction light syatem

RFX No. 4000045400 - SC 1000010333

• Dismantling & Shifting of Aviation Light Warning System from 17-Towers of Qassim Area & Supply & Installation of New Aviation Light Warning System on All 17- Towers

Page 2: Obstraction light syatem

17 - sites summary

Page 3: Obstraction light syatem
Page 4: Obstraction light syatem

System components.

• Double Warning Light

• Single warning lights

• OLC Panel Auto/Day/Night

• Resistive Photocell

• Cables

Page 5: Obstraction light syatem

Double and single Warning Light

• Available as a single, dual, or retrofit unit

• Available in 120-240VAC or 12-48VDC

• Grounding terminals provided

• Unique optical design (patent pending)

• Advanced high-flux LED technology

• Lasts years longer than an incandescent

• Weather/corrosion resistant lamp assembly and housing

• Self-contained wiring compartment eliminates additional boxes

• Threaded 1" and 3/4" bottom hub for mounting

• Can be operated steady or flashed

• Uses 95% less energy than incandescent

• Resistant to shock and vibration

• IP65 / IP66 / NEMA 4X

Page 6: Obstraction light syatem

OLC Panel

• Automatic fail safe to night mode and notification if system has not changed states in 19 hours

• Flash brand FREP power cable

• (1) Dry contact monitoring data point

• Patented optics eliminate ground scatter

• No EMI or RF

• Variable nominal supply voltage 120VAC or 240VAC

• Manual “ON–Auto–OFF” switch

• Photocell mode control with status indicators

• Lockable weatherproof enclosure

• Optional: GPS synchronization

• TIA-222G certified for all mounting hardware

Page 7: Obstraction light syatem

Resistive Photocell

• Housing: UV stabilized high-impact polypropylene

• Photocell: 1-inch cadmium sulfide light sensitive element

• Turn-on/Turn-off: 35 foot-candles turn-on; 58 foot-candles turn-off

• Time Delay: Minimum 15 seconds

• Switch Type: Single-pole, single-throw. Contact position at night normally

closed

• Temperature Range: -40°F to 170°F

• Power Consumption: 1.1 watts average at 120 VAC

• Rated Life: 5,000 operations minimum at rated load

• Surge Protection

• Dimensions: 3.07" diameter, 2.15" high

• Built-in time delay prevents false cycling caused by lightning flashes or stray headlights

• Meets FAA/FCC requirements for airway obstruction lighting

Page 8: Obstraction light syatem

Installation Diagram

Page 9: Obstraction light syatem

Installation Diagram (Zoom in)

Page 10: Obstraction light syatem

Installation Diagram(Zoom in)

Page 11: Obstraction light syatem
Page 12: Obstraction light syatem

The End

Thank You

Baud Telecom Company

Olayya Street, Al-Moussa CenterP. O. Box: 1223 - Riyadh 11431K.S.A.Tel.: +966 - 1 – 4650604Fax: +966 - 1 – 4653734www.btc.com.sa