USER MANUALMODEL NUMBER:DS4DS4KDS4VAND RELATED UNITS
Twin-Line Concentrate Doorway Foam Unit
English (Original Instructions)
Page 2 of 10 | 20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
Read this manual completely and understand the machine before operating or servicing it.• Readallinstructionsbeforeinstallingoroperatingunit.• Alwayswearappropriatepersonalprotectiveequipment
(PPE)whenoperatingorservicingunit.• Alwaysfollowallchemicalsafetyprecautionsand
handlinginstructionsprovidedbythechemicalmanufacturerandSafetyDataSheet(SDS).
• Ifthisunitismodifiedorservicedwithpartsnotlistedinthismanual,theunitmaynotoperatecorrectly.
• Donotexceedanincomingairpressureof100psi(7bar).
• Donotexceedafluidtemperatureof100˚F(37˚C).• Alwaysflushtheunitwithfreshwaterfor5minutes
whenswitchingfromanalkalinetoanacidoranacidtoanalkaline.
• Neveruseunitwithhydrocarbonsorflammableproducts.
• Onlyusecleananddryair.Airmustbefilteredandfreeofmoistureorpumplifewillbediminished.Ifneeded,installanairdryerbeforeunit.
• Donotuseanairlubricatorbeforetheunit.• Neveruseunitifitisdamagedorleaking.• Disconnectunitfromelectricalpowersourcebefore
servicing.
WARNING
PROTECT THE ENVIRONMENTPleasedisposeofpackagingmaterials,oldmachinecomponents,andhazardousfluidsinanenvironmentallysafewayaccordingtolocalwastedisposalregulations.
Alwaysremembertorecycle.
*Specificationsandpartsaresubjecttochangewithoutnotice.
OPTIONSPump Seal Material Number of Nozzles
DS4
Santoprene(standard)
-
One (standard)Viton (V) Two (2)
Kalrez(K) Three (3)Addboldoptioncodestoitemnumberasshown.Forstandardoptions,nooptioncodeisneeded.Examples:• DS4(standardunitwithSantoprenepumpsealsandone
nozzle)• DS4-2(unitwithSantoprenepumpsealsandtwo
nozzles)• DS4V-2(unitwithVitonpumpsealsandtwonozzles)
Page 3 of 10 | 20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
COMPLETE SYSTEMSItem Number: DS4 DS4-2 DS4-3Includes: Controlboxandonenozzle
assemblyControlboxandtwonozzleassemblies
Controlboxandthreenozzleassemblies
Spraytip: ST80200 ST80100 ST8060-1/2Foampattern: Upto9x5ft.(2.7x1.5m) Upto8x4ft.(2.4x1.2m)ateach
nozzleUpto6x3ft.(1.8x0.9m)ateachnozzle
Tubing(H12CP)included:
50ft.(15.2m) 100ft.(30.4m) 150ft.(45.7m)
Teefittings(QFT12)included:
0 2 4
REPLACEMENT NOZZLE ASSEMBLIESItem Number: GK7T GK7T-2 GK7T-3Includes: OnenozzleassemblywithST80200
spraytipOnenozzleassemblywithST80100spraytip,plusoneextraST80100spraytip
OnenozzleassemblywithST8060-1/2spraytip
Intendeduse: Replacementnozzlefora1-nozzlesystem
Replacementnozzlefora2-nozzlesystem,orconversionkittoturnanexisting1-nozzlesystemintoa2-nozzlesystem
Replacementnozzlefora3-nozzlesystem
Spraytip: ST80200 ST80100(alsoincludesanextratiptoretrofitanexistingnozzle)
ST8060-1/2
Tubing(H12CP)included:
50ft.(15.2m) 50ft.(15.2m) 50ft.(15.2m)
Teefittings(QFT12)included:
0 2 4
System Overview:Onecontrolboxcansupportuptothreenozzleassemblies.Thecombineddistancebetweenthecontrolboxandthenozzle(s)mustequal100ft.(30.5m)orless.
Page 4 of 10 | 20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
SPECIFICATIONSPowertype Compressedair,electricityChemicalpickuptype DrawsfromconcentratedproductDilutionratiorange(water:chemical)*
38:1to183:1
Numberofproductsunitcandrawfrom(andwhetheritdrawssimultaneouslyoroneatatime)
Oneproduct
Suctionlinelength/diameter 8ft.(2.4m)clearhosewith1/4in.(6.4mm)insidediameterFlowrate* 2gal/min(7.6l/min)Pumpseals Santoprene,Viton,orKalrezTimeroperationtype RepeatcycleCoveragearea Withonenozzle:upto9x5ft.(2.7x1.5m);
Withtwonozzles:upto8x4ft.(2.4x1.2m)ateachnozzle;Withthreenozzles:upto6x3ft.(1.8x0.9m)ateachnozzle
Fantip Withonenozzle:ST80200;Withtwonozzles:ST80100;Withthreenozzles:ST8060-1/2
Nozzletype Twin-linestainlesssteelnozzleassembly(GK7T)Numberofnozzles OnecontrolboxcansupportuptothreenozzleassembliesDistancefromnozzlestocontrolbox
Thecombineddistancebetweenthecontrolboxandthenozzle(s)mustequal100ft.(30.5m)orless.
Tubing/fittingsizes Designedforusewith1/2in.(12.7mm)outsidediametertubingbetweencontrolboxandnozzle(s)
*Dilutionratesandflowratesgivenarebasedonchemicalwithviscosityofwaterandfactoryairpressuresettings.
REQUIREMENTSCompressedairrequirements 40-80psi(3-5bar)with5-10cfm(141.6-283.3l/min)Waterrequirements 10-100psi(0.69-6.9bar)
Backflowpreventionisrequired–consultlocalplumbingordinancesformoreinformation.Liquidtemperaturerange 40-100˚F(4.4-37˚C)Electricalrequirements 120VACat60Hz,2amps(GFCIprotectedoutlet)Operatingvoltage 120VACChemicalcompatibility Chemicalproductsusedwiththisequipmentmustbeformulatedforthistypeofapplication
andcompatiblewithunitmaterialsandpumpseals.Formoreinformationonchemicalcompatibility,consultthemanufacturerorSDSforyourproductorcontactourcustomerservicedepartment.
Page5of10|20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
Installation Instructions:1. Removeallcomponentsfrompackaging.2. Selectanareatomountthecontrolbox.
Note:Thecontrolboxshouldbemountedtoaverticalwall.Werecommendmountingthecontrolboxataheightof6feetorless.Thechemicalsuctionlinemustreachthebottomofthechemicalcontainer.Thebottomofthechemicalcontainershouldnotbepositionedhigherthanthebottomofthecontrolbox.
3. Attachthecontrolboxmountingfeettothebackofthecontrolbox,usingthefourscrewsprovidedinthepartspackage.
4. Mountthecontrolboxtothewallusingfourofthescrewsandplasticanchorsprovidedinthepartspackage.Note:Todrillholesfortheplasticanchors,usea5/16inchdrillbit.
5. Mountthestainlesssteelnozzleassemblyinthedesiredlocation,usingtwostainlesssteelbrackets(SSFTB)andfourofthescrewsandplasticanchorsprovidedinthepartspackage.Repeatasneededformultiplenozzles.Note:Thefoampatterndimensionsprovidedinthismanualweremeasuredwithnozzleassembliesmounted6in.(15cm)abovethefloor.
6. Runtubingfromthesolutionoutletfittingonthecontrolboxtothesolutioninletfittingonthenozzleassembly.Formultiplenozzles,runthetubingfromthecontrolboxintoateefitting(QFT12),asshowninthediagram.Then,runtubingfromtheteefittingtothenozzleassemblies.Forsystemswiththreenozzles,useasecondteefittingtosplitthelineagain.
7. Runtubingfromtheairoutletfittingonthecontrolboxtotheairinletfittingonthenozzleassembly.Formultiplenozzles,splitthelineusingoneormoreteefittings(QFT12),asdescribedinstep6andshowninthediagram.Note:Theairandsolutionlinesmustberoutedtotheappropriatefittings(aslabeled),orthefoamqualityoftheunitwillbenegativelyimpacted.Makesuretoinsertthetubingallthewayintothefittingstoensureproperconnection.
TEE FITTING (QFT12) DIAGRAM
IN
OUT
OUT
IN
OUT OUT
Correct Incorrect
IN
OUT
OUT
IN
OUT OUT
Correct Incorrect
Connectingtheinlettothestemoftheteecreatesevendischarge
fromeachside
Connectingtheinlettoonesideoftheteecreatesuneven
discharge
8. Connecttheairinlethosebarb(HBSS1438)providedinthepartspackagetotheairinletvalve(BVB14)locatedonthesideofthecontrolbox.Thenattacha3/8inchI.D.airlinefromyouraircompressortotheairinlethosebarb,andsecureitwiththesmallerhoseclampprovidedinthepartspackage.
9. Connectawaterlinetotheunit.Thecontrolboxhasa1/2inchFPTwaterinletfitting(SSA12).Note:Aback-flowpreventermustbeinstalledinthewaterline–checklocalplumbingcodestoensureproperinstallation.
10.Openthecoverofthecontrolbox.Insertthepropermeteringtipandconnectthechemicalintakelinetotheinjectorinletbarb.Note:Usetheincludedmeteringtipcolorcharttodeterminetheappropriatemeteringtipbasedontheproductanddilutionrateyouwillbeusing.
11.
INJECTION RATESMETERING TIP COLOR OZ./GAL. RATIO*TAN 0.70 183-1ORANGE 0.90 142-1TURQUOISE 1.15 111-1PINK 1.55 83-1LIGHTBLUE 1.80 71-1
BROWN 1.85 69-1RED 2.65 48-1WHITE 3.40 38-1
**Injectionrateswillvarybasedonchemicalviscosity,airpressure,andmanyotherfactors.Werecommendtestingunitoutputtoverifyinjectionratepriortouse.
Placetheotherendofthechemicalintakelineintoachemicalcontainer.Note:Thechemicalsuctionlinemustreachthebottomofthechemicalcontainer.Astrainermustbeusedonthechemicalintakeline.
12.Setthetimerforthedesiredontimeandofftime,asdescribedinthetimeradjustmentinstructions.
Page6of10|20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
13.
TIMER ADJUSTMENT INSTRUCTIONS
120 VAC INPUT
OUT TOSOLENOIDS
FOA
M-IT
PN: TR
120DS-A
MIN
SEC
SEC
23
-+
1120 VA
C IN
LOA
D O
UT
1 2 4 8 16 32 64 128 256
GR
EE
N = O
UTP
UT O
N R
ED
= OU
TPU
T OFF
OFF TIM
E
ONMIN
CO
MB
INE
SW
ITCH
ES
FOR
TOTA
L TIME
ON
TIME
OFF
OFF
ON
1 2 4 8 16 32 64 128 256
TIMER ADJUSTMENT INSTRUCTIONS:The TR120DS-A is an adjustable repeat cycle timer with the “ON” time operating first. ON and OFF times can range from 1 second to 511 minutes.
1: Starting with the ON time, move the top dip switch to the left for SEC (seconds) or to the right for MIN (minutes) to set the desired time interval.
2: The next 9 dip switches will be used to control the total active time. To the left is inactive and to the right is active. Combine the numbers next to the active dip switches to achive the desired time.
3: Repeat the above steps for the OFF time setting.
TheTR120DS-AisanadjustablerepeatcycletimerwiththeONtimeoperatingfirst.ONandOFFtimescanrangefrom1secondto511minutes.
To set the timer:1. StartingwiththeONtime,movethetopdipswitchtotheleft
forSEC(seconds)ortotherightforMIN(minutes)toselectthedesiredtimeinterval.
2. Thenext9dipswitcheswillbeusedtocontrolthetotalactivetime.Totheleftisinactiveandtotherightisactive.Combinethenumbersnexttotheactivedipswitchestoachivethedesiredtime.
3. RepeattheabovestepsfortheOFFtimesetting.
WiththepowerswitchintheOFFposition,plugtheunitintoaGFCIprotected120VACpoweroutlet.
Operation Instructions:1. Verifythattheunitisconnectedtocompressedair,water,
power,andchemical.2. Openthecompressedairinletvalve(BVB14).3. Toactivatetheunit,turnthepowerswitchON.The
unitwillbegincyclingthroughtheontimeandofftimeintervalssetonthetimer,beginningwiththeontime.
4. Whiletheunitisrunninganddischargingproduct,adjusttheneedlevalve(NV14Y),locatedinsidethecontrolbox,asneededtoregulatethewetnessordrynessofthefoamfollowingthestepsbelow:a. Closeneedlevalve(NV14Y)completelyinclockwise
direction.b. Openneedlevalve(NV14Y)incounter-clockwise
direction2completeturns.c. Continuetoopenneedlevalvein¼turnincrements,
allowing30secondsbetweenadjustments,untildesiredconsistencyoffoamisachieved.
5. Todeactivatetheunit,turnthepowerswitchOFF.
Page 7 of 10 | 20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
Maintenance Instructions:Tokeepyourfoamunitoperatingproperly,periodicallyperformthefollowingmaintenanceprocedures:Note:Beforeperforminganymaintenance,ensurethattheunithasbeenturnedOFF,unpluggedfromtheelectricalpowersource,anddisconnectedfromtheair/watersupply.• Inspectthepump(P56/P56K/P56V)forwearandleaks.• Inspectallhosesforleaksorexcessivewear.Makesureall
hoseclampsandpush-fittingsareingoodconditionandproperlysecured.
• Replacethefilter(AFR25)locatedwithintheairregulator(R25)asneeded.Cleanbyunthreadingtheairregulatorbowl(ABR25)fromtheairregulator(R25).
• Checkthechemicalmeteringtip,suctionlineandstrainerfordebrisandcleanasneeded.
• Drainyouraircompressortankonaregularbasistohelpextendpumplife.Anairsourcewithahighmoisturecontentwillacceleratepumpwear.Note:Ifyourairsourcehasahighmoisturecontent,youmaywishtoinstallawaterseparator(itemnumberWS-20CFM,soldseparately)beforetheunit.
Troubleshooting Instructions:• Checktheairregulatorbowl(ABR25)andairfilter(AFR25)
fordebrissuchaswater,oil,orrustparticles.Cleanbyunthreadingtheairregulatorbowl(ABR25)fromtheairregulator(R25).
• Iftheneedlevalve(NV14Y)isopentoofar,thepump(P56/P56K/P56V)maycycleimproperlyduetolackofairpressure.Ifthisoccurs,closeandreadjusttheneedlevalve(NV14Y)asdescribedinOperationInstruction#2.
• Makesureproperfoamingchemicalandconcentrationarebeingused.
• Ifairpassesthroughthepump(P56/P56K/P56V)withoutcycling,thepumpneedstobereplaced.
• Ifsolutionbacksupintotheairregulatorbowl(ABR25),thecheckvalve(CV38)needstobereplaced.
• Iffoamcomesoutwet,nomatterwheretheneedlevalve(NV14Y)ispositioned,thecheckvalve(CV38)mayneedtobereplaced.
• Checkforproperairpressureontheairgauge(AG100).Theairregulator(R25)isfactorysetat50psi(3.4bar).Operatingrangeis40to80psi(3to5bar)with3.5to8CFM(99to226.5l/min).
• Iftheunitoperatesatareducedpressure: o Checktheaircompressorsupplyingtheunit.Ifthepressureislessthan40psi,turntheunitoffuntilthecompressorcancatchup.
o Iftheairsupplyis50psi(3.4bar)orabove,checktheairgauge(AG100),whichshouldreadnear50psi(3.4bar).Iftheairgaugereadsmoreorlessthan50psi(3.4bar),adjustthepressurebyturningtheknobonthetopoftheairregulator(R25).
• Checkthechemicalmeteringtip,suctionlineandstrainerfordebrisordamage.Cleanorreplaceasneeded.Topreventdamagetotheunit,thestrainermustalwaysbeused.
• Checkforproperwaterpressureonthewaterpressuregauge(WRG14).Tocheckthepressure:
o Activatetheunitandallowittorunthroughanontimecycle.
o Duringthesubsequentofftimecycle,checkthewaterpressuregauge(WRG14).Thepressureshouldread30psi(2.1bar)duringtheofftimecycleorwhendeadheaded.
o Ifnecessary,adjustthewaterregulatorusingtheflatheadscrewontheregulatorbody.Thewaterpressureshouldbesetat30psi(2.1bar)whendeadheaded.Settingthepressurehigherorlowermaydamagetheunitorcauseittomalfunction.
Page8of10|20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
PBFT-PP
CC8463
TS2PLATE
TS2TSBT12
SN1414
CC3224BVB14
WR1A
PB16138-LATCH
R25DT
TR120DS-A
TS2
SN1414
R25
ACV1
SN1414
AG100
QF1212
NV14Y
FWP78
SSE12
SSA12
WR12SS
WRG14
P56-BRKT-SCREW
CV38
HBSSEL1438
HBF3812
PN1238
P56-BRKT
P56, P56K or P56V
ACV1D38
P203CT
HBELF3838
CONTROL BOX ASSEMBLY
Page9of10|20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
NOZZLE ASSEMBLY
SSE12
SSE12
QF1212
CV12F7-AP
HHSB11412
SN1212
SSFT
ST80200, ST80100 or ST8060-1/2
SST12
QF1212
HHSB11412
SN1212
(Spraytipsizevariesbasedonnumberofnozzleassembliesused-seespecifcationschartformoreinformation.) ABTN12
ABTNTB12
NOZZLE ASSEMBLY DETAILThisunitincludesanadjustableball-typenozzlethatmaybeinstalledtoholdthespraytipasshown.
PARTS INFORMATION - LEGACY/DISCONTINUED COMPONENTS
LEGACYPARTSDIAGRAM
PEL34F
HHSB34GH12
SSA12
WR15G34
PN3834ITEM NUMBER DESCRIPTIONHHSB34GH12 STAINLESSHEXHEADBUSHING3/4inMGHBY1/2FPT
PEL34F 3/4inFEMALEPOLYPIPEELBOW90
PN3834 POLYREDUCERNIPPLE3/8inMPTX3/4inMPT
WR15G34 WATERPRESSUREREGULATOR-3/4inFGHBY3/4inMPTBodyABS,internalparts,SS,PPandSanto
LEGACYPARTSLISTLEGACY WATER REGULATOR ASSEMBLY
Conversion kit to upgrade to current water inlet: CK-WR12SS.
Page 10 of 10 | 20170403
User Manual: Twin-Line Concentrate Doorway Foam Unit | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: DS4, DS4K, DS4V
ITEM NUMBER DESCRIPTION
ABTN12 ADJUSTABLEBALL-TYPENOZZLE1/2inNPT
ABTNTB12 1/2inTHREADEDBALLFORABTN12
ACV1 MACVALVE1/4in110VAC
ACV1D38 110VACSOLENOIDVALVE3/8in
AG100 1.5INCHDRYMODEL20DUALSCALEGAUGE
B10321 10-32X1PHILTRUSSMACHSCR18-8
B10321.25 10-32X11/4PHILTRUSSMACH18-8
BVB14 AIRINLETVALVE-VABRS025-4F4F-BT,NICKEL
CC3224 LTCBLACK1/2NPT
CC8463 1/2inNPTBLACKLOCKNUT
CV12F7-AP 1/2CHECKVALVE7LBSPRING-HASTELLOYSPRING-EPSEALS-ACIDPROOF-BLK/WHTCHK
CV38 PVCCHECKVALVE3/8BARBS-SSSPRING
EC14-2 OETIKERCLAMP13.8
FWLG14 .569IDX1.28ODX.08THICKFLATWASHERSS18-8
FWP12 7/8IDX1.5ODX0.05THKSSFW
FWP78 7/8inBY.137BY11/4inFLATWASHER18-8PLN
H12CP 1/2INODPOLYETHYLENETUBING-NATURAL-Availableperft.
H14B-H 1/4INCHBLUEHOSE-Availableperft.
H38B-H 3/8INCHBLUEHOSE-Availableperft.
HBELF3838 HOSEBARBELBOW3/8”BYFPT3/8”
HBF3812 HOSEBARB3/8XFEMALEPIPETHREAD1/2IN
HBSS1438 STAINLESSHOSEBARB1/4MPTX3/8BARB
HBSSEL1438 STAINLESSHOSEBARBELBOW1/4NPTX3/8HOSEBARB
HBSSEL1814 304STAINLESSELBOW1/8INCHNPTX1/4INCHHOSEBARB
HHSB11412 HEXHEADSTAINLESSBUSHING11/4INBY12IN
NV14Y FLOWCONTROLVALVE-INCLUDESBLACKKNOB
NV14Y-HNDL BLACKKNOBFORNEEDLEVALVE-2839-1/4
P203CT PLASTICINJECTORKITINCLUDESINJECTOR-INTAKEHOSE-FOOTSTRAINERANDWEIGHT-TIPKIT
P56 5700PUMPWITHSANTOPRENESEALS-INCLUDESHOSEBARBS,AIRFITTING,ANDAIRPORT
P56K 5700PUMPWITHKALREZSEALS-INCLUDESHOSEBARBS,AIRFITTING,ANDAIRPORT
P56V 5700PUMPWITHVITONSEALS-INCLUDESHOSEBARBS,AIRFITTING,ANDAIRPORT
20756103B PolyproG57AirPortxHBStraight,w/Vitono-ring
HB14P 1/4inBRASSHBAIRFITTING/G57/P56
HB5638 HOSEBARBFORP56PUMP
HB5638K HOSEBARBFORP56KPUMP
HB5638V HOSEBARBFORP56VPUMP
P56-BRKT PUMPBRACKET-STAINLESSSTEEL
P56-BRKT-SCREW
HILOSCREWFORRETAININGP56-BRKT
PB16138 POLYPROPYLENECONTROLBOX-WORKINGDIMS16x13x8-PUMPMOUNT
PB16138-GSKT NEOPRENEGASKET0.220INCHROUNDCORDSTOCK-61.125INCHES
PB16138-LATCH
LATCHFORPB16138
PB16138-PIN STAINLESSSTEELHINGEPINFORCONTROLBOXPB16138
PBFT-PP MOUNTINGFEETFORPOLYBOX-PB16138-POLYPROPYLENE
PL16138 POLYPROPYLENE-16x13x8-HINGEDLOCKABLELID
PN1238 1/2inMPTX3/8inMPTPOLYNIPPLE
QF1212 MALECON.1/2inTUBEX1/2inMPT-POLYPROPYLENE
QFT12 UNIONTEE1/2inTUBE-POLYPROPYLENE
R25 AIRREGULATOR-1/4fptTWOPORT1/8fptTWOPORT-INCLUDESFILTERANDBOWL
AFR25 AIRFILTERforR25
ABR25 METALAIRBOWLforR25
R25DT CLEARTUBINGFORR25DRAIN
S1034FHL 10X3/4PHILFLATHI-LOTHRDSCREW18-8
SN1212 1/2inHEXSTAINLESSSTEELNIPPLE
SN1414 STAINLESS1/4MPTX1/4MPTNIPPLE
SSA12 STAINLESSMALE/FEMALES.S.ADAPTOR1/2inX1/2in
SSC38 WORMGEARCLAMP,S/S(.25-.63)
SSE12 STREETELBOW1/2in-316S.S.
SSFT StainlessSteelFoamTube11/2in@8INCHCUT
SSFTB STAINLESSSTEELFOAMTUBEBRACKET
SSMESH STAINLESSSTEELMESH
SSST [email protected]
SST12 1/2inFPT304S.S.TEE
ST80100 VEEJETNOZZLE,80100
ST80200 VEEJETNOZZLE,80200
ST8060-1/2 1/2INCHVEEJETNOZZLE,BRASS8060
TR120DS-A REPEATCYCLETIMER-ADJUSTABLEDIGI-SET-120VAC
TS2 TOGGLESWITCHSPST
TS2PLATE ON/OFFSWITCHPLATE
TSBT12 TOGGLESWITCHBOOT
WCB14F 14-16-1/4FEMINSULATEDCONNECTOR
WCB14FY 10-12-1/4inFEMALEINSULATEDCONNECTOR
WMS14 14X11/4HEXW/HSMSSLOTT,S/S
WMS14A 5/16X11/2STRAIGHTPLASTICANCHOR
WR12SS WATERPRESSUREREGULATOR-STAINLESSSTEEL-1/2INCHFPT
WR1A 18/3SJOOW90BLACKN.A.W/5-15P&7inROJ
WRG14 WATERPRESSUREREGULATORGAUGEFORWR12SS