Transcript
Page 1: Thermo compressors REV02 - steritec.files.wordpress.com · • Possibility to produce cold WFI water ... meets the latest requirements of the international Pharmacopeias including

Vapour Compression Stills

MainfeaturesTheprinciplefeaturesofthestilmasthermocompressorare:• PossibilitytoproducecoldWFIwater of25°Corhotof85°Cduetolowvelocityseparation• Noneedcoolingwater• Highenergeticperformance dueanoptimizedconfigurationoftheheatrecoverysystemanddesignofthe

compressor• Fastresponse:instandbyconditionsthedistillateisproducedin10minutes• Reducedandeasymaintenance withalonglifeofthethermocompressor• Duetolackofhightemperaturesoftenedfeedwater issuitable• Non-condensablegasesarehighlyefficientremoved

Operatingprinciple• Feedwaterispre-heatedinthreeheadexchangerstorecoverthesensibleheatofproduced

WFI,concentratedandNon-condensableGases.• Thefeedwateristhensendtothestillmainbodybottom,whereitispre-heatedtoevaporation

temperaturebyanexternalenergysource– electricalorsteam.• Theevaporationtakesplaceinaverticalshellandtubeheatexchangerwhichisanintegralpart

ofthestillbody• Theproducedsteamisflowingintotheevaporationcolumnwherethedecontaminationoccurs.• Thepuresteamsthansuckedbythecompressorandsendbacktothesametubeheatexchanger• Theslightlypressurizedsteamcondensesatahighertemperaturethantheboilingwatertube

side,sotransferringthelatentheat.• ThecondensedWFIissenttothehydrostaticcolumnfordegassingandfinallyispressurizedbya

sanitarypump,senttotheheatrecoverysystemandthentobatterylimits.

Contact

Steritec BelgiumAv.J.Wybran45 BBE-1070 BrusselsT+32(0)252011 50E [email protected]

Steritec TheNederlandsVanNelleweg6060*NL-3044BCRotterdamPostbox13060*NL-3004HBRotterdamT+31 (0)10 753 72 21E [email protected]

ConstructionTheplantiscompletelymadeinAISI316Lstainlesssteel,thefinishingoftheactivesurfacesarepickledandpassivatedandmirrororelectropolishing(to0,6µR)canbemadeonrequest.Product(WFI)contactpartsaremechanicallypolishedandpipingisorbitallywelded.Forbestpossibleinspection,thedecontaminationchamberistotallyempty.Theabsenceinthisareaofweldingdramaticallyreducestheriskofcorrosion,foraverylongexpectedlife.Thepre-heaterincontactwithNon-condesablegasesisshellandtubeDTS.

StilmasindustrialcompanyhasengineeredtheVapourcompressionseriesthatproducedistilledWaterforInjectionthatmeetsthelatestrequirementsoftheinternationalPharmacopeiasincludingUSP,EPandJP.StilmasThermocompressorsSeriescanbefedwithdeionizedwaterorevensoftenedwater.TheycanalsobeusedtoproduceUSPpurifiedwater.

Page 2: Thermo compressors REV02 - steritec.files.wordpress.com · • Possibility to produce cold WFI water ... meets the latest requirements of the international Pharmacopeias including

THE SPECIALISTS IN STERILIZATION TECHNOLOGIES

CompressorsTechnology

Therearetwoalternativesolutionsforthesteamcompressordeveloped.Bothtypesarecharacterisedbyanextremelylimitedandeasymaintenancethatconsistsinbearingssubstitutionevery8000– 10000workinghoursdonebycustomers’technicians.

FA- HRSSeries

Thevolumetriccompressorisequippedwitharotarypiston.• Constructedinabronzealloy,nickelplated• IschemicaldepositionFDA-approved• Lowrotationalspeed,implyinglownoiseandasimplemechanicalexecution(Lessthan700rpm).• Specialtransmissionforpreventinganyoilcontamination

BD– ThermopharmaStillSeries

Equippedwithsidechannelblower.• Thebodyandrotorisconstructedinaluminiumandnickelplated.TheshaftisinAISI316L.• IschemicaldepositionFDA-approved.• RotorinstalledontwoexternalbearingswithmechanicalsealsFDA-approved.• Low/Mediumrationalspeed, implyinglownoiseandasimplemechanicalexecution (Lessthan2.000rpm).• Limitedandeasymaintenancerequired