Download pdf - Tesys b Lc1bl33m22

Transcript
Page 1: Tesys b Lc1bl33m22

The

info

rmat

ion

prov

ided

in th

is d

ocum

enta

tion

cont

ains

gen

eral

des

crip

tions

and

/or t

echn

ical

cha

ract

eris

tics

of th

e pe

rform

ance

of t

he p

rodu

cts

cont

aine

d he

rein

.Th

is d

ocum

enta

tion

is n

ot in

tend

ed a

s a

subs

titut

e fo

r and

is n

ot to

be

used

for d

eter

min

ing

suita

bilit

y or

relia

bilit

y of

thes

e pr

oduc

ts fo

r spe

cific

use

r app

licat

ions

.It

is th

e du

ty o

f any

suc

h us

er o

r int

egra

tor t

o pe

rform

the

appr

opria

te a

nd c

ompl

ete

risk

anal

ysis

, eva

luat

ion

and

test

ing

of th

e pr

oduc

ts w

ith re

spec

t to

the

rele

vant

spe

cific

app

licat

ion

or u

se th

ereo

f.N

eith

er S

chne

ider

Ele

ctric

Indu

strie

s SA

S no

r any

of i

ts a

ffilia

tes

or s

ubsi

diar

ies

shal

l be

resp

onsi

ble

or li

able

for m

isus

e of

the

info

rmat

ion

cont

aine

d he

rein

.

11.03.20131

Product data sheetCharacteristics

LC1BL33M22bar-mounted contactor - TeSys LC1-BL - 3poles - AC-3 440V 750 A - coil 220V AC

MainRange of product TeSys BProduct or componenttype

Contactor

Device short name LC1BLContactor application Motor-heating-lightingUtilisation category AC-1

AC-3Control circuit type ACCoil type StandardPoles description 3PPole contactcomposition

3 NO

[In] rated current 750 A ≤ 55 °C AC AC-3 power circuit800 A ≤ 40 °C AC AC-1 power circuit

Motor power kW 220 kW 220...230 V AC 50/60 Hz400 kW 380...400 V AC 50/60 Hz425 kW 415 V AC 50/60 Hz450 kW 440 V AC 50/60 Hz500 kW 500 V AC 50/60 Hz530 kW 1000 V AC 50/60 Hz560 kW 660...690 V AC 50/60 Hz

Control circuit voltage 220 V AC 50...400 Hz

ComplementaryAuxiliary contact composition 2 NO + 2 NCControl circuit voltage limits 0.3...0.5 Uc drop-out 50...400 Hz

0.85...1.1 Uc operational 50...400 Hz[Ui] rated insulation voltage 1000 V IEC 60158-1 power circuit

1000 V IEC 60947-4 power circuit1500 V VDE 0110 group C power circuit

Mounting mode FixedMounting support Bar support bracket

Notched mounting railsConnections - terminals Bars power circuit 2 50 x 5 mmTightening torque 21 N.m power circuit bars[Ue] rated operational voltage <= 1000 V AC 50/60 Hz power circuit[Ith] conventional free air thermal current 800 A ≤ 40 °C power circuitIrms rated making capacity 10000 A 1000 V AC power circuit IEC 60947-4

10000 A 1000 V AC power circuit IEC 60158-1Rated breaking capacity 4000 A 1000 V power circuit IEC 60158-1

4000 A 1000 V power circuit IEC 60947-48000 A 660...690 V power circuit IEC 60158-18000 A 660...690 V power circuit IEC 60947-49000 A 500 V power circuit IEC 60158-19000 A 500 V power circuit IEC 60947-410000 A 440 V power circuit IEC 60947-410000 A 440 V power circuit IEC 60158-1

Associated fuse rating 800 A aM <= 440 V power circuit800 A gI <= 440 V power circuit1000 A gI <= 440 V power circuit

Average impedance 0,18 mOhm 50 Hz 800 A power circuitPower dissipation per pole 88 W AC-3 800 A

115 W AC-1 800 AInrush power in VA 1300 VA 50/60 HzHold-in power consumption in VA 31 VA 50/60 Hz

Page 2: Tesys b Lc1bl33m22

2

Operating time 50...100 ms opening100...150 ms closing

Mechanical durability 1200000 cyclesOperating rate 120 cyc/h ≤ 55 °CHeight 486 mmWidth 570 mmDepth 475 mmProduct weight 58 kg

EnvironmentStandards BS 5424

IEC 60158-1IEC 60947-4NF C 63-110VDE 0660

Product certifications BVCSARINA

Protective treatment TCTH

Ambient air temperature for operation -5...55 °CAmbient air temperature for storage -60...80 °COperating altitude 3000 m withoutRoHS EUR conformity date 4Q2008RoHS EUR status Will not be compliant

Garantie contractualaPeriod 18 luni