2
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 11.03.2013 1 Product data sheet Characteristics LC1BL33M22 bar-mounted contactor - TeSys LC1-BL - 3 poles - AC-3 440V 750 A - coil 220V AC Main Range of product TeSys B Product or component type Contactor Device short name LC1BL Contactor application Motor-heating-lighting Utilisation category AC-1 AC-3 Control circuit type AC Coil type Standard Poles description 3P Pole contact composition 3 NO [In] rated current 750 A ≤ 55 °C AC AC-3 power circuit 800 A ≤ 40 °C AC AC-1 power circuit Motor power kW 220 kW 220...230 V AC 50/60 Hz 400 kW 380...400 V AC 50/60 Hz 425 kW 415 V AC 50/60 Hz 450 kW 440 V AC 50/60 Hz 500 kW 500 V AC 50/60 Hz 530 kW 1000 V AC 50/60 Hz 560 kW 660...690 V AC 50/60 Hz Control circuit voltage 220 V AC 50...400 Hz Complementary Auxiliary contact composition 2 NO + 2 NC Control circuit voltage limits 0.3...0.5 Uc drop-out 50...400 Hz 0.85...1.1 Uc operational 50...400 Hz [Ui] rated insulation voltage 1000 V IEC 60158-1 power circuit 1000 V IEC 60947-4 power circuit 1500 V VDE 0110 group C power circuit Mounting mode Fixed Mounting support Bar support bracket Notched mounting rails Connections - terminals Bars power circuit 2 50 x 5 mm Tightening torque 21 N.m power circuit bars [Ue] rated operational voltage <= 1000 V AC 50/60 Hz power circuit [Ith] conventional free air thermal current 800 A ≤ 40 °C power circuit Irms rated making capacity 10000 A 1000 V AC power circuit IEC 60947-4 10000 A 1000 V AC power circuit IEC 60158-1 Rated breaking capacity 4000 A 1000 V power circuit IEC 60158-1 4000 A 1000 V power circuit IEC 60947-4 8000 A 660...690 V power circuit IEC 60158-1 8000 A 660...690 V power circuit IEC 60947-4 9000 A 500 V power circuit IEC 60158-1 9000 A 500 V power circuit IEC 60947-4 10000 A 440 V power circuit IEC 60947-4 10000 A 440 V power circuit IEC 60158-1 Associated fuse rating 800 A aM <= 440 V power circuit 800 A gI <= 440 V power circuit 1000 A gI <= 440 V power circuit Average impedance 0,18 mOhm 50 Hz 800 A power circuit Power dissipation per pole 88 W AC-3 800 A 115 W AC-1 800 A Inrush power in VA 1300 VA 50/60 Hz Hold-in power consumption in VA 31 VA 50/60 Hz

Tesys b Lc1bl33m22

Embed Size (px)

DESCRIPTION

automatizari

Citation preview

Page 1: Tesys b Lc1bl33m22

The

info

rmat

ion

prov

ided

in th

is d

ocum

enta

tion

cont

ains

gen

eral

des

crip

tions

and

/or t

echn

ical

cha

ract

eris

tics

of th

e pe

rform

ance

of t

he p

rodu

cts

cont

aine

d he

rein

.Th

is d

ocum

enta

tion

is n

ot in

tend

ed a

s a

subs

titut

e fo

r and

is n

ot to

be

used

for d

eter

min

ing

suita

bilit

y or

relia

bilit

y of

thes

e pr

oduc

ts fo

r spe

cific

use

r app

licat

ions

.It

is th

e du

ty o

f any

suc

h us

er o

r int

egra

tor t

o pe

rform

the

appr

opria

te a

nd c

ompl

ete

risk

anal

ysis

, eva

luat

ion

and

test

ing

of th

e pr

oduc

ts w

ith re

spec

t to

the

rele

vant

spe

cific

app

licat

ion

or u

se th

ereo

f.N

eith

er S

chne

ider

Ele

ctric

Indu

strie

s SA

S no

r any

of i

ts a

ffilia

tes

or s

ubsi

diar

ies

shal

l be

resp

onsi

ble

or li

able

for m

isus

e of

the

info

rmat

ion

cont

aine

d he

rein

.

11.03.20131

Product data sheetCharacteristics

LC1BL33M22bar-mounted contactor - TeSys LC1-BL - 3poles - AC-3 440V 750 A - coil 220V AC

MainRange of product TeSys BProduct or componenttype

Contactor

Device short name LC1BLContactor application Motor-heating-lightingUtilisation category AC-1

AC-3Control circuit type ACCoil type StandardPoles description 3PPole contactcomposition

3 NO

[In] rated current 750 A ≤ 55 °C AC AC-3 power circuit800 A ≤ 40 °C AC AC-1 power circuit

Motor power kW 220 kW 220...230 V AC 50/60 Hz400 kW 380...400 V AC 50/60 Hz425 kW 415 V AC 50/60 Hz450 kW 440 V AC 50/60 Hz500 kW 500 V AC 50/60 Hz530 kW 1000 V AC 50/60 Hz560 kW 660...690 V AC 50/60 Hz

Control circuit voltage 220 V AC 50...400 Hz

ComplementaryAuxiliary contact composition 2 NO + 2 NCControl circuit voltage limits 0.3...0.5 Uc drop-out 50...400 Hz

0.85...1.1 Uc operational 50...400 Hz[Ui] rated insulation voltage 1000 V IEC 60158-1 power circuit

1000 V IEC 60947-4 power circuit1500 V VDE 0110 group C power circuit

Mounting mode FixedMounting support Bar support bracket

Notched mounting railsConnections - terminals Bars power circuit 2 50 x 5 mmTightening torque 21 N.m power circuit bars[Ue] rated operational voltage <= 1000 V AC 50/60 Hz power circuit[Ith] conventional free air thermal current 800 A ≤ 40 °C power circuitIrms rated making capacity 10000 A 1000 V AC power circuit IEC 60947-4

10000 A 1000 V AC power circuit IEC 60158-1Rated breaking capacity 4000 A 1000 V power circuit IEC 60158-1

4000 A 1000 V power circuit IEC 60947-48000 A 660...690 V power circuit IEC 60158-18000 A 660...690 V power circuit IEC 60947-49000 A 500 V power circuit IEC 60158-19000 A 500 V power circuit IEC 60947-410000 A 440 V power circuit IEC 60947-410000 A 440 V power circuit IEC 60158-1

Associated fuse rating 800 A aM <= 440 V power circuit800 A gI <= 440 V power circuit1000 A gI <= 440 V power circuit

Average impedance 0,18 mOhm 50 Hz 800 A power circuitPower dissipation per pole 88 W AC-3 800 A

115 W AC-1 800 AInrush power in VA 1300 VA 50/60 HzHold-in power consumption in VA 31 VA 50/60 Hz

Page 2: Tesys b Lc1bl33m22

2

Operating time 50...100 ms opening100...150 ms closing

Mechanical durability 1200000 cyclesOperating rate 120 cyc/h ≤ 55 °CHeight 486 mmWidth 570 mmDepth 475 mmProduct weight 58 kg

EnvironmentStandards BS 5424

IEC 60158-1IEC 60947-4NF C 63-110VDE 0660

Product certifications BVCSARINA

Protective treatment TCTH

Ambient air temperature for operation -5...55 °CAmbient air temperature for storage -60...80 °COperating altitude 3000 m withoutRoHS EUR conformity date 4Q2008RoHS EUR status Will not be compliant

Garantie contractualaPeriod 18 luni