Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design. Patented design delivering genuine solution for new and retrofit solutions to replace 400W HID. Delivers a system life of 100,000 hours.
Value Proposition
Application
Rail Logistics Sports Retail
Exhibition Halls
Prismatic Glass Optics
Thermal Shock
Chemical Resistance
Low Dirt Accumulation Recyclable
Temp Resistance
Longevity
UV Impervious
Why Glass?
Lumen Maintenance
Discomfort Glare
Optical Performance
Colour Consistency
Minimising LED Failure
Maximising Optical Control
Optical Performance
Broad Distribution 1.2:1 to 1.7:1
Extensive Distribution 1.7:1 to 2.2:1
Intensive Distribution 0.9:1 to 1.2:1
Focused Distribution 0.7:1 to 0.9:1
System Longevity
System Life of over 100,000 hours at L70F10.
Product Specification
70CRI or 80CRI options available.
Lumen packages ranging from 20,000 to 39,000 with efficacies of 101 lpw. IP20 luminaire with IP65 optical chamber. TA -20oC to +45oC. Wire guard and safety chain attachment options. Single or Twin Suspension.
Emergency
No emergency kit available with the power to run the LED’s. Limited space within the luminaire.
EMCA Recap Three hours non-maintained emergency solution.
Emergency ballast with DALI as standard and integrated battery
pack (12V/340mA)
Emergency indicator built into
cover plate.
Safety chain attachment included
as standard.
Performance Data
Product Code
Drive Current
(mA)
Lumens+ Power Consumption
(W)*
Luminaire Performance
(LPW)
Power Factor
(Ø)
HAL.L3947 700mA c.38500 385 100 TBC
HAL.L3247 700mA c.31869 308 103 TBC
HAL.L2247 700mA c.22106 230 94 TBC
HAL.L3448 700mA c.34000 385 89 TBC
HAL.L2748 700mA c.27000 308 87 TBC
HAL.L2048 700mA c.20000 235 85 TBC
* Subject to final testing +Dependent on distribution.
Performance Data
40
50
60
70
80
90
100
25oC 35oC 40oC 45oC
Life
(000's
)
Ambient Temp
System LED
Estimated system rated life of 100,000 hrs L70F10 @ TA 25oC.
LED life of >100,000 hours
New Build Performance Example
Parameters Dirty environment Reflectance’s C50%, W30%, F10% Room dimensions (m): Length: 50, Width: 30, Height: 9. Luminaire Installation height of 9m. Total area 450m2 Target Lux : 500 , Uniformity : >0.60 as per BSEN12464-1 2011’
28 luminaires 45 luminaires
Retrofit Performance Example
Existing Luminaires 84 400W HIE High bay luminaire Luminous flux: 32,500 lm Luminous efficiency: 75 lm/W or 50 6x80 Whitecroft Fluorescent Luminous flux: 39300 lm Luminous efficiency: 74 lm/W
HALOPRISM Retrofit 50 HALOPRISM high bay luminaires Luminous flux: c24,000 lm Luminous efficiency: 102 lm/W
Retrofit Choosing replacement method
Optimised replacement One-for-One replacement
Retrofit Using the right Maintenance Factor for every application
𝐌𝐅 = 𝐋𝐋𝐌𝐅 × 𝐋𝐌𝐅 × 𝐑𝐒𝐌𝐅
MF LLMFLMF (10000
hours)
RSMF ( 2yrs
cleaning)
Haloprism 0.91 1 0.97 0.94
Gentlespace 0.81 1 0.86 0.94
Durosite 0.81 1 0.86 0.94
Litex 0.81 1 0.86 0.94
Cooper high bay 0.74 1 0.79 0.94
Zumtobel Graf 0.81 1 0.86 0.94
PLS HTPSP 0.73 0.92 0.982 0.81
PPS HTPSP 0.85 0.92 0.982 0.94
I-Beam 0.81 1 0.86 0.94
Proteon 0.81 1 0.86 0.94
T5 80W 0.50 0.9 0.59 0.94
HIE 400W (magnetic) 0.37 0.66 0.59 0.94
• Every installation has MF 1 (100%) at time 00:00
• MF can emphasize the importance of a quality, long lasting luminaire
• MF affects the quantities of the luminaires, especially when there is high depreciation.
• The MF used by competitor should be known and validated.
𝐋amp 𝐋umen 𝐌aintenance 𝐅actor
𝐋uminaire 𝐌aintenance 𝐅actor
𝐑oom 𝐒urface 𝐌aintenance 𝐅actor
Controlling Haloprism DALI controlled
1. Well established protocol in the market
2. Compatible with any standard DALI system
3. No necessity for a bespoke control solution unless required
4. 3 addresses / luminaire more demanding wiring and commissioning.
5. The design must be always assessed from a controls point of view before giving
budget cost.
6. Any last minute changes should always be reported to verify they are within the
control system’s potential.
7. Avoid frequent on/off switching.
8. A single driver model will be released in the near future (currently being tested)
Performance Amortisation on Retrofit Installation Including luminaire and running cost
Performance Amortisation on Retrofit Installation Including luminaire and running cost
Exceptional vertical illumination Improved Light Control Better Uniformity Low Glare
Increase in task performance
Reduction in number
of rejects
Accident Reduction
=
Analogue Fast Dim 1-10V (.ANF). DALI control (3 x DALI addresses) Constant Lumen Output 70%, 80% & 90% maintaining 50% of the LED light engines or LED’s. Standalone high-bay analogue presence detector PIR kit for 360o and aisle.
Controls
HEL.PIR
Key Competitors
Key Competitors
Product Lumen Range
LPW CRI Lifetime@ L70
Ta IP Rating
Controls Option
DALI/1-10V
12,600 – 28,000
90 - 100 70 & 80
50,000 TBC IP65 DALI
11,000 - 25,000
80-102 70 100000 -40oC
to 65oC IP66 No
10,000 - 24,000
82 – 93 75 75,000 -30oC
to 45oC IP65 DALI
10,300 – 20,700
95-105 75 50,000 -30oC
to 40oC IP65 DALI
20,000 – 39,000
85-101 70 & 80
100000 -20oC
to 45oC
IP20/ IP65 (optic)
DALI and 1-10V
Product Positioning
Product Positioning
- Passive convective cooling - Light weight and rigid construction - Direct replacement for fluorescent luminaires - 100,000 system life but limited lumen maintenance
- Premium MIRO Silver reflector system - Dynamic temperature sensing and control. - Pluggable and removable driver tray. - Luminaire designed to conduct and convect heat. - 25,000 hours system life.
- Unique prismatic glass lens with LED technology - PrismaLED. - Highest lumen package available. - Advanced lumen Maintenance. - Thermal management delivers a system life of 100,000. - Sealed optical chamber.
Marketing Support
Marketing Support