technology. - holophane-envision.co.uk Generic/Holophane/Englis… · Proteon 0.81 1 0.86 0.94 T5 80W 0.50 0.9 0.59 0.94 HIE 400W (magnetic) 0.37 0.66 0.59 0.94 • Every installation

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design. Patented design delivering genuine solution for new and retrofit solutions to replace 400W HID. Delivers a system life of 100,000 hours.

    Value Proposition

  • Application

    Rail Logistics Sports Retail

    Exhibition Halls

  • Prismatic Glass Optics

    Thermal Shock

    Chemical Resistance

    Low Dirt Accumulation Recyclable

    Temp Resistance

    Longevity

    UV Impervious

  • Why Glass?

  • Lumen Maintenance

  • Discomfort Glare

    Optical Performance

    Colour Consistency

    Minimising LED Failure

    Maximising Optical Control

  • Optical Performance

    Broad Distribution 1.2:1 to 1.7:1

    Extensive Distribution 1.7:1 to 2.2:1

    Intensive Distribution 0.9:1 to 1.2:1

    Focused Distribution 0.7:1 to 0.9:1

  • System Longevity

    System Life of over 100,000 hours at L70F10.

  • Product Specification

    70CRI or 80CRI options available.

    Lumen packages ranging from 20,000 to 39,000 with efficacies of 101 lpw. IP20 luminaire with IP65 optical chamber. TA -20oC to +45oC. Wire guard and safety chain attachment options. Single or Twin Suspension.

  • Emergency

    No emergency kit available with the power to run the LED’s. Limited space within the luminaire.

  • EMCA Recap Three hours non-maintained emergency solution.

    Emergency ballast with DALI as standard and integrated battery

    pack (12V/340mA)

    Emergency indicator built into

    cover plate.

    Safety chain attachment included

    as standard.

  • Performance Data

    Product Code

    Drive Current

    (mA)

    Lumens+ Power Consumption

    (W)*

    Luminaire Performance

    (LPW)

    Power Factor

    (Ø)

    HAL.L3947 700mA c.38500 385 100 TBC

    HAL.L3247 700mA c.31869 308 103 TBC

    HAL.L2247 700mA c.22106 230 94 TBC

    HAL.L3448 700mA c.34000 385 89 TBC

    HAL.L2748 700mA c.27000 308 87 TBC

    HAL.L2048 700mA c.20000 235 85 TBC

    * Subject to final testing +Dependent on distribution.

  • Performance Data

    40

    50

    60

    70

    80

    90

    100

    25oC 35oC 40oC 45oC

    Life

    (000's

    )

    Ambient Temp

    System LED

    Estimated system rated life of 100,000 hrs L70F10 @ TA 25oC.

    LED life of >100,000 hours

  • New Build Performance Example

    Parameters Dirty environment Reflectance’s C50%, W30%, F10% Room dimensions (m): Length: 50, Width: 30, Height: 9. Luminaire Installation height of 9m. Total area 450m2 Target Lux : 500 , Uniformity : >0.60 as per BSEN12464-1 2011’

    28 luminaires 45 luminaires

  • Retrofit Performance Example

    Existing Luminaires 84 400W HIE High bay luminaire Luminous flux: 32,500 lm Luminous efficiency: 75 lm/W or 50 6x80 Whitecroft Fluorescent Luminous flux: 39300 lm Luminous efficiency: 74 lm/W

    HALOPRISM Retrofit 50 HALOPRISM high bay luminaires Luminous flux: c24,000 lm Luminous efficiency: 102 lm/W

  • Retrofit Choosing replacement method

    Optimised replacement One-for-One replacement

  • Retrofit Using the right Maintenance Factor for every application

    𝐌𝐅 = 𝐋𝐋𝐌𝐅 × 𝐋𝐌𝐅 × 𝐑𝐒𝐌𝐅

    MF LLMFLMF (10000

    hours)

    RSMF ( 2yrs

    cleaning)

    Haloprism 0.91 1 0.97 0.94

    Gentlespace 0.81 1 0.86 0.94

    Durosite 0.81 1 0.86 0.94

    Litex 0.81 1 0.86 0.94

    Cooper high bay 0.74 1 0.79 0.94

    Zumtobel Graf 0.81 1 0.86 0.94

    PLS HTPSP 0.73 0.92 0.982 0.81

    PPS HTPSP 0.85 0.92 0.982 0.94

    I-Beam 0.81 1 0.86 0.94

    Proteon 0.81 1 0.86 0.94

    T5 80W 0.50 0.9 0.59 0.94

    HIE 400W (magnetic) 0.37 0.66 0.59 0.94

    • Every installation has MF 1 (100%) at time 00:00

    • MF can emphasize the importance of a quality, long lasting luminaire

    • MF affects the quantities of the luminaires, especially when there is high depreciation.

    • The MF used by competitor should be known and validated.

    𝐋amp 𝐋umen 𝐌aintenance 𝐅actor

    𝐋uminaire 𝐌aintenance 𝐅actor

    𝐑oom 𝐒urface 𝐌aintenance 𝐅actor

  • Controlling Haloprism DALI controlled

    1. Well established protocol in the market

    2. Compatible with any standard DALI system

    3. No necessity for a bespoke control solution unless required

    4. 3 addresses / luminaire more demanding wiring and commissioning.

    5. The design must be always assessed from a controls point of view before giving

    budget cost.

    6. Any last minute changes should always be reported to verify they are within the

    control system’s potential.

    7. Avoid frequent on/off switching.

    8. A single driver model will be released in the near future (currently being tested)

  • Performance Amortisation on Retrofit Installation Including luminaire and running cost

  • Performance Amortisation on Retrofit Installation Including luminaire and running cost

    Exceptional vertical illumination Improved Light Control Better Uniformity Low Glare

    Increase in task performance

    Reduction in number

    of rejects

    Accident Reduction

    =

  • Analogue Fast Dim 1-10V (.ANF). DALI control (3 x DALI addresses) Constant Lumen Output 70%, 80% & 90% maintaining 50% of the LED light engines or LED’s. Standalone high-bay analogue presence detector PIR kit for 360o and aisle.

    Controls

    HEL.PIR

  • Key Competitors

  • Key Competitors

    Product Lumen Range

    LPW CRI Lifetime@ L70

    Ta IP Rating

    Controls Option

    DALI/1-10V

    12,600 – 28,000

    90 - 100 70 & 80

    50,000 TBC IP65 DALI

    11,000 - 25,000

    80-102 70 100000 -40oC

    to 65oC IP66 No

    10,000 - 24,000

    82 – 93 75 75,000 -30oC

    to 45oC IP65 DALI

    10,300 – 20,700

    95-105 75 50,000 -30oC

    to 40oC IP65 DALI

    20,000 – 39,000

    85-101 70 & 80

    100000 -20oC

    to 45oC

    IP20/ IP65 (optic)

    DALI and 1-10V

  • Product Positioning

  • Product Positioning

    - Passive convective cooling - Light weight and rigid construction - Direct replacement for fluorescent luminaires - 100,000 system life but limited lumen maintenance

    - Premium MIRO Silver reflector system - Dynamic temperature sensing and control. - Pluggable and removable driver tray. - Luminaire designed to conduct and convect heat. - 25,000 hours system life.

    - Unique prismatic glass lens with LED technology - PrismaLED. - Highest lumen package available. - Advanced lumen Maintenance. - Thermal management delivers a system life of 100,000. - Sealed optical chamber.

  • Marketing Support

  • Marketing Support