7/29/2019 Surge Protector - Datasheet Type - PV 29 Pink Series (http://shop.acdc-dcac.eu/)
1/2
AC DC MOS Protector Type - PV 29 Pink Series is compact stand alone
The surge Protector of type ACDC Surge Pro-tector - Pink Series is 3 (three) stages Single Phase Protector in metalenclosures with applications for load currents of up to 8A .
multi surge protect ( ) & A protection stageprovide effective and reliable protection against surges and transients
EMI/RFI filtering
The scope of applications of ACDC Surge Protectors is quitewide and refers to the protection of electrical devices against impulse surgeand high-frequency (electromagnetic) disturbance, oscillation, speaks innetwork power supply and atmospheric discharge.
-stage or consists of 3 three 8 s thats . The
protection device have high grade cascade bi-directional ofphase (L) and neutral (N) wire.
ACDC protectors have
high-grade cascade bidirectional filtering. They are tracking AC waveformeliminating so-called pollution in power AC supply.
These protectors have special design to protect and improve functioning ofsophisticate equipment as Computers, Telecommunications, Medicalequipment, Home electrical appliances and other.
The surge Protector of type ACDC Surge Protector - PinkSeries is compact stand alone unit and it is install quickly and easily tostandard electrical Schuko outlets on principle PLUG and PLAY. The option
for connectors is C13 and C14 plug or terminal block.
Application:
Installation:
Technical Specifications:
Reliability: If the stages 1 and 3 are out of function, the stage 2 is stillprovide a high grade bi-directional filtering.
- Size (WxDxH): 150x50x30mm
- Led Lamp Signalization
- C13
Sur e ProtectionG
CLASSCLASSII+IIIII+III 2020
IPIP3322
LPZLPZhomeomecameraamera officeofficecomputeromputer
Surur eMULTI-STAGE SURGE PROTECTIONULTI-STAGE SURGE PROTECTION
www.acdc-dcac.euEmpowered by Innovation
ACDC SURGE PROTECTOR
THREE (3) STAGES 1/1SERIES PROTECTOR
Type-PV 29 Pink Series
TOP VIEW
SIDE VIEW
CONNECTORS
30
150
150
50
- C14
Metal Enclosu res
Single Phase CLASS II+III
120VAC /230VAC 8
Total Surge Cur.: 55
Load Rating: & A
Response Time: < 1nskA (8x20 s)PLUG IN INSTALLATION
ACDC ors have five ( )
and -
on
TVS . That with
re
Multi-Stage Surge Protect built-in 5
patents use four (4) complementary different prote
cti technologies, (Varistor, Gas Tube, Nanocrystalline
Cores and technology) in one unit result
ducing the surge current up to 99.9% at single point.
Innovation Approuch to Surge Protection
his characteristic not -
and
can offer competitive surge pro
ducts present a fundamental improvement inTSurge Protection technology. ACDC
Surge Protectors a applicable f professions
such as planners, construction engineers, designers,
electricians and others.
Implementation of
resimple and or
7/29/2019 Surge Protector - Datasheet Type - PV 29 Pink Series (http://shop.acdc-dcac.eu/)
2/2
MULTI-STAGE SURGE PROTECTIONULTI-STAGE SURGE PROTECTIONSurur eTechnical SpecificationType - PV 29 Pink Series
[email protected] ACDC DCAC Dan e Krapc ev n o.2/1 , 1000-Sko pj e, Macedo ni a Phon e: 3 89 2 3216 988; Fax : 389 2 3216 993
Basic Circuit Diagram - Pink Series:
GreenTechnology
Multi-Stage Surge Protection
Three (3) Stages Series Protector
Specification
Load
Basic
Installation
Product Standard
Bi-directional EMI-RFI filtering of
phase (L) and neutral (N) wire
In the front is installed fuse 10A
Indication for load
Plug-in installation, schuko plug, connectors C13
and C14, terminal block or acc. requirements
IEC61643-1 Class II+III; IEC60939-2
C
ThermalCut-Off
Var. Control
GTD
Bi-directionalFilter
(No back EMF effect)
C
ThermalCut-Off
Var.
Control
GTD
N,LOUT
L,NOUT
GND
L,NIN
N,LIN
GND
O.S.10A
Protection StageTechnical Specification
Surge Cur. 40kA (8/20s)1. First s tage
L=10mH; Imax=up to 8A
3. Third s tage
2. Second stage
Function Technology
Nano Cr stalline Core
(L-C configuration)
y
Suppression signal shape
(L-N) 8/20 s,
Varistor with thermal cut-off
Control Gas Tube Discharge
;
ACDC Surge Protector Type-PV 29 Pink Seri es
Bi-directional EMI/RFI filter;
;Front signal edge reduction
Surge Cur. 15kA (8/20s)
Suppression signal shape
(L-N) 8/20 s,
Varistor with thermal cut-off
Control Gas Tube Discharge
;
Type
Order Code
Total Surge Cur.
Dimension (WxDxHmm)
Weight (kg)
Type - PV 29
400.115
55kA (8/20 )s
150 30x50x
0,47
Single Phase ACDC Surge Protectors Type - PV 29 Pink Series
Applications: Features:
Certificate of Quality
Varistors Standard
E
Pro Standard acc.
lect. Magn. Interfer.
tec.
ISO 9001:200
UL 1449
IEC 60
IEC 61643-1 lass
8
IEC 61643-1;
939-2
C II +III
Integrate Multi - Protection System
Protection Stages
Bi-directional Wave Filtering
Thermal Circuit Protection
High Reliability
Response Time
Stage
Three
Expel Ground Contamination
Excellent
Computers
Servers
Telecommunication
Medical equipment
Sensitive electronic
Industrial grade
Audio & Video
Application:
ACDC SURG E
PROTECTOR
Safe Power Supply
Waveform Tracking Filter
Random Noice
Voltage Spike
U(V)U(V)
t (ms)5 10 15 20
Camera
Office
Home
Power Supply
Up to 8A single phase; up to 900W load for
120VAC; up to 1,6kW load for 230VAC