www.metalcraftgroup.co.nz
Architectural / Specification EnquiriesPh: 09 274 0408
Mobile: 027 603 1096Email: [email protected]
Thermopanel EPS
TPWD
EXTERNAL WALL DETAILS
MetalcraftInsulated Panel Systems
00 / 21 COVER SHEET01 / 21 PARAPET02 / 21 WINDOW HEAD03 / 21 WINDOW SILL AND JAMB04 / 21 VERTICAL JOINT TYPE C05 / 21 PIPE PENETRATION w DEKTITE FLASHING06 / 21 PIPE PENETRATION w PVC FLANGE07 / 21 MIDFLOOR JOINT08 / 21 SECRET FIXING JOINT 0109 / 21 SECRET FIXING JOINT 0210 / 21 METERBOX JAMB HEAD AND SILL DETAIL11 / 21 INTERNAL/EXTERNAL CORNER DETAIL12 / 21 ALTERNATIVE INTERNAL CORNER13 / 21 ALTERNATE EXTERNAL CORNER14 / 21 ABUTMENT 0115 / 21 ABUTMENT 0216 / 21 BOTTOM OF CLADDING 0117 / 21 BOTTOM OF CLADDING 0218 / 21 BOTTOM OF CLADDING 0319 / 21 BOTTOM OF CLADDING 0420 / 21 BOTTOM OF CLADDING 0521 / 21 PANEL PROFILE AND SIZE
DETAIL LIST
EPS PACKER
PRE-FINISHED SCREWWITH RUBBER WASHER
METALCRAFTTHERMOPANEL
STRUCTURE BY OTHERS
PRE-FINISHED PARAPET CAPFLASHING NO FIXINGS ON TOPOF FLASHING
ø5mm RIVETS @ 300mm CRS
5.00
°
VAPOUR RESISTANT MASTIC SEALANT
200m
m M
IN.
200m
m M
IN.
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
PARAPET
01 / 2130.08.2016
METALCRAFTTHERMOPANEL
TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING
PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL
DOUBLE GLAZING WINDOW JOINERY
AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILLAND JAMB
WINDOW HEAD LINER
LINE OF WINDOW JAMBLINER BEHIND
EXPANDALBE WATERTIGHTCOMPRIBAND TAPE
SILICON SEALANTØ5mm RIVETS @ 300mm CRS
SILICON SEALANT
ALUMINIUM JOINERY
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
WINDOW HEAD
02 / 2130.08.2016
DOUBLE GLAZING WINDOW JOINERY
LINE OF WINDOW JAMB LINER BEHIND
WINDOW SILL LINER EXPANDALBE WATERTIGHTCOMPRIBAND TAPE
Ø5mm RIVETS @ 300mm CRS
ALUMINIUM JOINERY
METALCRAFTTHERMOPANEL
SILICON SEALANT
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
WINDOW SILL AND JAMB
03 / 2130.08.2016
METALCRAFT THERMOPANEL
Ø5mm RIVETS @ 300mm CRS.
TOP-HAT SECTION. COLOURAS REQUIRED. (RIVETS ANDSEALANT UNDER EACH LEGOF TOP-HAT)
TIMBER
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
SEALANT
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
VERTICAL JOINT TYPE C
04 / 2130.08.2016
METALCRAFTTHERMOPANEL WALL
DEKTITE PIPE FLASHING
Ø5mm RIVETS @ 300mm CRS
300mm Ø MAX. PIPE
0.55mm INTERNAL FLASHING OR PVCFLANGE
OUTSIDE INSIDE
SEALANT
ENSURE TIGHT FIT TO CORE MATERIAL,ALTERNATIVELY, USE EXPANDING FOAM
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
PIPE PENETRATION w DEKTITE FLASHING
05 / 2130.08.2016
METALCRAFTTHERMOPANEL WALL
Ø5mm RIVETS @ 300mm CRS
300mm Ø MAX. PIPE
0.55mm INTERNAL FLASHING OR PVCFLANGE
OUTSIDE INSIDE
ENSURE TIGHT FIT TO CORE MATERIAL,ALTERNATIVELY, USE EXPANDING FOAM
SEALANT
SEALANT
SEALANT
0.55mm INTERNAL FLASHING OR PVCFLANGE
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
PIPE PENETRATION w PVC FLANGE
06 / 2130.08.2016
METALCRAFT THERMOPANEL
Ø 6mm DRAINAGEHOLES @ 1000mm CTRS
ø5mm RIVETS @ 300mm CRS.
50m
m M
IN.
100m
m M
IN.
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING
TIMBER
VAPOUR RESISTANT MASTIC SEALANT
0.55 SECONDARY FLASHING ORALUMINIUM ANGLE FIXED TOPANEL BEFORE INSTALMENT
PRE-FINISHED FLASHING WITH15° FALL
COMPRESSIBLE FOAM SEAL TO FILLOVERLAP OF FLASHING
099A PVC FOAM TAPE
VAPOUR RESISTANT MASTIC SEALANT
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
MIDFLOOR JOINT
07 / 2130.08.2016
METALCRAFTTHERMOPANEL WALL
SECRET FIXINGS @ 300mm CRS.
VAPOUR RESISTANT MASTIC SEALANT
EXTERNAL
INTERNAL
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
SECRET FIXING JOINT 01
08 / 2130.08.2016
METALCRAFTTHERMOPANEL
VAPOUR RESISTANTMASTIC SEALANT
EXTERNAL
INTERNAL
TIMBER
5mm ALUMINIUMANGLE CLEAT
ALUMINIUM BASECAP 300mm LONG MIN
ø5mm RIVETS
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
SECRET FIXING JOINT 02
09 / 2130.08.2016
METALCRAFTTHERMOPANEL METERBOX
PVC SLEEVE FORCABLE ACCESS
ALUMINIUMANGLE
SEALANT
ø5mm RIVETS@ 300crs
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
METERBOX JAMB HEAD AND SILL DETAIL
10 / 2130.08.2016
METALCRAFT THERMOPANEL
Ø5mm RIVETS @ 300mm CRS.
40mm x 40mm 0.55mm MIN.FOLDED ALUMINIUMEXTERNAL ANGLE
40mm x 40mm 0.55mm MIN.FOLDED ALUMINIUM
INTERNAL ANGLE
Ø5mm RIVETS @ 300mm CRS
Ø5mm RIVETS @ 300mm CRS.WITH SEALANT
SEALANT
NOTE:ALUMINIUM ANGLES CAN BEREPLACED WITH STEEL
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
INTERNAL/EXTERNAL CORNER DETAIL
11 / 2130.08.2016
METALCRAFTTHERMOPANEL
Ø5mm RIVETS @ 300mm CRS.
Ø5mm RIVETS @ 300mm CRS
VAPOUR RESISTANT MASTIC SEALANT
Ø40mm WASHER AND M10 ZPHEX NUT
TIMBER
0.55 SECONDARY FLASHING OR ALUMINUMANGLE
100m
m M
IN.
PRE-FINISHED FLASHING
40x40 ALUMINUM ANGLE
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
ALTERNATIVE INTERNAL CORNER
12 / 2130.08.2016
METALCRAFT THERMOPANEL
Ø5mm RIVETS @ 300mm CRS
VAPOUR RESISTANT MASTIC SEALANT
TIMBER
40 x 40 ALUMINIUM ANGLE ON SEALANT
170mm MIN.
PRE-FINISHED FLASHING
PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
ALTERNATE EXTERNAL CORNER
13 / 2130.08.2016
METALCRAFTTHERMOPANEL
Ø5mm RIVETS
VAPOUR RESISTANT MASTIC SEALANT
TIMBER
PAINTED CONCRETE BY OTHERS
70mm MIN.
PRE-FINISHED FLASHING
Ø6.5mm / 32 mm SHUREDRIVES @ 300mmCRS. OR AS SPECIFIED BY ENGINEER
ALUMINUM CHANNEL
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
VAPOUR RESISTANT MASTIC SEALANT
FOAM BACKING ROD
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
ABUTMENT 01
14 / 2130.08.2016
METALCRAFT THERMOPANEL
Ø5mm RIVETS @ 300mm CRS
VAPOUR RESISTANT MASTIC SEALANT
STRUCTURE BY OTHERS
PAINTED CONCRETE BY OTHERS
Ø6.5mm / 32 mm SHUREDRIVES @ 300mmCRS. OR AS SPECIFIED BY ENGINEER
200mm
PRE-FINISHED FLASHING
FOAM BACKING ROD
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
ABUTMENT 02
15 / 2130.08.2016
METALCRAFT THERMOPANEL WALL
ø6mm DRAINAGEHOLES @ 1000 CRS
ø5mm RIVETS @ 300mm CRS.
100m
m M
IN.
TIMBER
PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING
VAPOUR RESISTANT MASTIC SEALANT
0.55 SECONDARY FLASHINGFIXED TO PANEL BEFOREINSTALMENTPRE-FINISHED FLASHING WITH
15° FALL
DPC LAYER
75
50
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
BOTTOM OF CLADDING 01
16 / 2130.08.2016
METALCRAFT THERMOPANEL
PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING
VAPOUR RESISTANT MASTIC SEALANT
DPC LAYER
SEALANT
FOAM BACKING ROD
SEALANT
ALUMINUM CHANNEL
Ø5mm RIVETS
CONCRETE
Ø6.5mm / 32 mm SHUREDRIVES @ 300mmCRS. OR AS SPECIFIED BY ENGINEER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
BOTTOM OF CLADDING 02
17 / 2130.08.2016
METALCRAFT THERMOPANEL
ø6mm DRAINAGEHOLES @ 1000 CRA
ø5mm RIVETS @ 300mm CRS.
Z
TIMBER
PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING
VAPOUR RESISTANT MASTIC SEALANT
0.55 SECONDARY FLASHINGFIXED TO PANEL BEFOREINSTALMENT
DPC LAYER
50
PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
BOTTOM OF CLADDING 03
18 / 2130.08.2016
METALCRAFT THERMOPANEL
TIMBER
VAPOUR RESISTANT MASTIC SEALANT
ALUMINIUM BASE SUPPORT CHANNEL
50
PRE-FINISHED SELF-TAPPING TEKSCREW
ø5mm RIVETS @ 300mm CRS.
SEALANT
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
BOTTOM OF CLADDING 04
19 / 2130.08.2016
METALCRAFT THERMOPANEL WALL
STRUCTURE BY OTHERS
VAPOUR RESISTANT MASTIC SEALANT
ALUMINIUM BASE SUPPORT CHANNEL
50
PRE-FINISHED SELF-TAPPING TEKSCREW
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2
BOTTOM OF CLADDING 05
20 / 2130.08.2016
INTERNAL LINER FINISHES
SILKLINE FINISH
- ONE SIDE ONLY
MESA FINISH
- ONE SIDE ONLY
RIBBED FINISH
- AVAILABLE BOTH SIDES
15 30
2
107 4 12
127
939.8 39.8
97.5
21
THERMOPANEL EPS
FLAT FINISH - AVAILABLE BOTH SIDES
SCALE @ 1:5
SCALE @ 1:2
A= 50, 75, 100, 125,150, 200, 250mm
A
1200
Reference
DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.
ScaleDate SheetTPWD
Thermopanel Wall DetailsMetalcraftInsulated Panel Systems As indicated
PANEL PROFILE AND SIZE
21 / 2130.08.2016