N
PROPOSED ARRAY FENCE
2 13456789101112
2 13456789101112
B
TITLE
SIZE DRAWINGNUMBER
REV
DATEENGINEERED BYDRAWN BYD
205 BILLINGS FARM ROAD, BUILDING 4WHITE RIVER JUNCTION, VERMONT [email protected]
THIS DRAWING AND SPECIFICATIONS CONTAINED HEREON IS PROPRIETARY TOGROSOLAR AND IS LOANED TO FACILITATE BIDDING, CONSTRUCTION, FABRICATION
AND/OR EXECUTION OF REQUIREMENTS STATED AND IS TO BE SURRENDEREDUPON REQUEST OR COMPLETION OF SERVICES
PROJECT
LOCATION
REV CHK BY APV BYDATEREVISIONS
A
C
D
E
F
G
H
B
A
C
D
E
F
G
H
DESCRIPTIONSCALE SHEET
PROJECTNUMBER
PRELIMINARY SITE PLAN
E-1TBD CESB JMM 05-19-2015
1 IN = 50 FT 1 OF 1
TOWN OF CLIFTON PARK SOLAR217 VISCHER FERRY ROADCLIFTON PARK, NY 12148
A ISSUED FOR REVIEW 02-10-2015B UPDATED LAYOUT, NEW EQUIPMENT TRANSFORMER AREA 03-26-2015C REVISED AND REISSUED FOR INTERCONNECTION 05-19-2015
ISSUED FOR INTERCONNECTIONNOT FOR CONSTRUCTION
NOTES
1. SITE SPECIFIC FACTORS SUCH AS: TOPOGRAPHY,SHADING, ACCESS DRIVES, DRAINAGE, EXISTINGBUILDINGS, PV EQUIPMENT, PAD LOCATIONS, AND ORUTILITY INTERCONNECTION AREA COULD CHANGE THEFINAL ARRAY LAYOUT AND POWER OUTPUT.
2. THE ARRAY ROW SPACING SHOWN WILL PREVENTSHADING BETWEEN 10AM-2PM ON DECEMBER 21ST.
3. SITE PREPARATION AND PRELIMINARY LAYOUT FOR THECLIFTON PARK LANDFILL SITE IS BASED ONINFORMATION PROVIDED BYC.T. MALE ASSOCIATESENGINEERING, SURVEYING AND ARCHITECTURE D.P.C.,FROM DRAWING #15-145, NAMED TOPOGRAPHIC SURVEYPORTION OF LOT 1 OF TOWN OF CLIFTON PARK LANDFILLSHEET 1 OF 1, PROJECT #14.4727 LATEST REVISIONDATED 01/ 26/ 2015.
PROPOSEDINVERTER,
EQUIPMENT, ANDTRANSFORMER
PADSUNDERGROUND FEEDERSTO EQUIPMENT PAD
APPROXIMATE EXISTING POLE,POINT OF INTERCONNECTION ANDPOCC, UTILITY ISOLATION SWITCH
PROPOSEDENTRANCE
SYSTEM SUMMARY?????????????????
????
??????????????
???
MODULE POWER (Wp) 325
NUMBER OF MODULES 3060
RATED DC POWER (kWp) 994.5
INVERTER AC CAPACITY (kWAC) 742.4PROPOSED GRAVELACCESS DRIVE
APPROXIMATE EXISTING ELECTRICAL UTILITY POLE
APPROXIMATE EXISTING GAS VENT, TYPICAL.
APPROXIMATE EXISTING OVERHEAD ELECTRIC CIRCUIT
LEGEND
APPROXIMATE VENT PIPE WITH 15FT RADIUS SETBACK
PL APPROXIMATE EXISTING PROPERTY LINE
PROPOSED RACK - (2) VERTICAL ROWS OF 9 MODULES
MV MV MV PROPOSED UNDERGROUND MEDIUM VOLTAGE CIRCUIT
APPROXIMATEEXISTING WELL
LOCATION,SETBACK TBD
TRANSITION FROMABOVE GROUND TO
UNDERGROUND OFF OFTHE LANDFILL
OE OE OE PROPOSED OVERHEAD ELECTRIC CIRCUIT
PROPOSED PV ARRAY
AC AC AC PROPOSED LV ABOVE GROUND ELECTRIC CIRCUIT
UG UG UG PROPOSED LV UNDERGROUND ELECTRIC CIRCUIT
LINE EXTENSION BYGROSOLAR
APPROXIMATEEXISTING POLE, RISERPOLE, GENERATORISOLATION SWITCH
NEW METER POLE,NATIONAL GRID METER