1
PL PL PL PL PL PL PL PL PL PL PL PL PL PL MV MV MV UG UG UG UG AC AC AC AC AC AC AC AC N PROPOSED ARRAY FENCE 2 1 3 4 5 6 7 8 9 10 11 12 2 1 3 4 5 6 7 8 9 10 11 12 B TITLE SIZE DRAWING NUMBER REV DATE ENGINEERED BY DRAWN BY D 205 BILLINGS FARM ROAD, BUILDING 4 WHITE RIVER JUNCTION, VERMONT 05001 800-374-4494 [email protected] THIS DRAWING AND SPECIFICATIONS CONTAINED HEREON IS PROPRIETARY TO GROSOLAR AND IS LOANED TO FACILITATE BIDDING, CONSTRUCTION, FABRICATION AND/OR EXECUTION OF REQUIREMENTS STATED AND IS TO BE SURRENDERED UPON REQUEST OR COMPLETION OF SERVICES PROJECT LOCATION REV CHK BY APV BY DATE REVISIONS A C D E F G H B A C D E F G H DESCRIPTION SCALE SHEET PROJECT NUMBER PRELIMINARY SITE PLAN E-1 TBD C ESB JMM 05-19-2015 1 IN = 50 FT 1 OF 1 TOWN OF CLIFTON PARK SOLAR 217 VISCHER FERRY ROAD CLIFTON PARK, NY 12148 A ISSUED FOR REVIEW 02-10-2015 B UPDATED LAYOUT, NEW EQUIPMENT TRANSFORMER AREA 03-26-2015 C REVISED AND REISSUED FOR INTERCONNECTION 05-19-2015 ISSUED FOR INTERCONNECTION NOT FOR CONSTRUCTION NOTES 1. SITE SPECIFIC FACTORS SUCH AS: TOPOGRAPHY, SHADING, ACCESS DRIVES, DRAINAGE, EXISTING BUILDINGS, PV EQUIPMENT, PAD LOCATIONS, AND OR UTILITY INTERCONNECTION AREA COULD CHANGE THE FINAL ARRAY LAYOUT AND POWER OUTPUT. 2. THE ARRAY ROW SPACING SHOWN WILL PREVENT SHADING BETWEEN 10AM-2PM ON DECEMBER 21ST. 3. SITE PREPARATION AND PRELIMINARY LAYOUT FOR THE CLIFTON PARK LANDFILL SITE IS BASED ON INFORMATION PROVIDED BYC.T. MALE ASSOCIATES ENGINEERING, SURVEYING AND ARCHITECTURE D.P.C., FROM DRAWING #15-145, NAMED TOPOGRAPHIC SURVEY PORTION OF LOT 1 OF TOWN OF CLIFTON PARK LANDFILL SHEET 1 OF 1, PROJECT #14.4727 LATEST REVISION DATED 01/ 26/ 2015. PROPOSED INVERTER, EQUIPMENT, AND TRANSFORMER PADS UNDERGROUND FEEDERS TO EQUIPMENT PAD APPROXIMATE EXISTING POLE, POINT OF INTERCONNECTION AND POCC, UTILITY ISOLATION SWITCH PROPOSED ENTRANCE SYSTEM SUMMARY $55$< $=,087+ $55$< 7,/7 MODULE POWER (Wp) 325 NUMBER OF MODULES 3060 RATED DC POWER (kWp) 994.5 INVERTER AC CAPACITY (kWAC) 742.4 PROPOSED GRAVEL ACCESS DRIVE APPROXIMATE EXISTING ELECTRICAL UTILITY POLE APPROXIMATE EXISTING GAS VENT, TYPICAL. APPROXIMATE EXISTING OVERHEAD ELECTRIC CIRCUIT LEGEND APPROXIMATE VENT PIPE WITH 15FT RADIUS SETBACK PL APPROXIMATE EXISTING PROPERTY LINE PROPOSED RACK - (2) VERTICAL ROWS OF 9 MODULES MV MV MV PROPOSED UNDERGROUND MEDIUM VOLTAGE CIRCUIT APPROXIMATE EXISTING WELL LOCATION, SETBACK TBD TRANSITION FROM ABOVE GROUND TO UNDERGROUND OFF OF THE LANDFILL OE OE OE PROPOSED OVERHEAD ELECTRIC CIRCUIT PROPOSED PV ARRAY AC AC AC PROPOSED LV ABOVE GROUND ELECTRIC CIRCUIT UG UG UG PROPOSED LV UNDERGROUND ELECTRIC CIRCUIT LINE EXTENSION BY GROSOLAR APPROXIMATE EXISTING POLE, RISER POLE, GENERATOR ISOLATION SWITCH NEW METER POLE, NATIONAL GRID METER

Solar project site plan JUN 2015.pdf

Embed Size (px)

Citation preview

  • PL

    PL

    PL

    PL

    PL

    PL

    PL

    PL

    PL

    PL

    PL

    PL

    PL

    PL

    MV

    MV

    MV

    UG

    UG

    UG

    UG

    AC

    A

    C

    AC

    A

    C

    AC

    AC AC AC

    N

    PROPOSED ARRAY FENCE

    2 13456789101112

    2 13456789101112

    B

    TITLE

    SIZE DRAWINGNUMBER

    REV

    DATEENGINEERED BYDRAWN BYD

    205 BILLINGS FARM ROAD, BUILDING 4WHITE RIVER JUNCTION, VERMONT [email protected]

    THIS DRAWING AND SPECIFICATIONS CONTAINED HEREON IS PROPRIETARY TOGROSOLAR AND IS LOANED TO FACILITATE BIDDING, CONSTRUCTION, FABRICATION

    AND/OR EXECUTION OF REQUIREMENTS STATED AND IS TO BE SURRENDEREDUPON REQUEST OR COMPLETION OF SERVICES

    PROJECT

    LOCATION

    REV CHK BY APV BYDATEREVISIONS

    A

    C

    D

    E

    F

    G

    H

    B

    A

    C

    D

    E

    F

    G

    H

    DESCRIPTIONSCALE SHEET

    PROJECTNUMBER

    PRELIMINARY SITE PLAN

    E-1TBD CESB JMM 05-19-2015

    1 IN = 50 FT 1 OF 1

    TOWN OF CLIFTON PARK SOLAR217 VISCHER FERRY ROADCLIFTON PARK, NY 12148

    A ISSUED FOR REVIEW 02-10-2015B UPDATED LAYOUT, NEW EQUIPMENT TRANSFORMER AREA 03-26-2015C REVISED AND REISSUED FOR INTERCONNECTION 05-19-2015

    ISSUED FOR INTERCONNECTIONNOT FOR CONSTRUCTION

    NOTES

    1. SITE SPECIFIC FACTORS SUCH AS: TOPOGRAPHY,SHADING, ACCESS DRIVES, DRAINAGE, EXISTINGBUILDINGS, PV EQUIPMENT, PAD LOCATIONS, AND ORUTILITY INTERCONNECTION AREA COULD CHANGE THEFINAL ARRAY LAYOUT AND POWER OUTPUT.

    2. THE ARRAY ROW SPACING SHOWN WILL PREVENTSHADING BETWEEN 10AM-2PM ON DECEMBER 21ST.

    3. SITE PREPARATION AND PRELIMINARY LAYOUT FOR THECLIFTON PARK LANDFILL SITE IS BASED ONINFORMATION PROVIDED BYC.T. MALE ASSOCIATESENGINEERING, SURVEYING AND ARCHITECTURE D.P.C.,FROM DRAWING #15-145, NAMED TOPOGRAPHIC SURVEYPORTION OF LOT 1 OF TOWN OF CLIFTON PARK LANDFILLSHEET 1 OF 1, PROJECT #14.4727 LATEST REVISIONDATED 01/ 26/ 2015.

    PROPOSEDINVERTER,

    EQUIPMENT, ANDTRANSFORMER

    PADSUNDERGROUND FEEDERSTO EQUIPMENT PAD

    APPROXIMATE EXISTING POLE,POINT OF INTERCONNECTION ANDPOCC, UTILITY ISOLATION SWITCH

    PROPOSEDENTRANCE

    SYSTEM SUMMARY?????????????????

    ????

    ??????????????

    ???

    MODULE POWER (Wp) 325

    NUMBER OF MODULES 3060

    RATED DC POWER (kWp) 994.5

    INVERTER AC CAPACITY (kWAC) 742.4PROPOSED GRAVELACCESS DRIVE

    APPROXIMATE EXISTING ELECTRICAL UTILITY POLE

    APPROXIMATE EXISTING GAS VENT, TYPICAL.

    APPROXIMATE EXISTING OVERHEAD ELECTRIC CIRCUIT

    LEGEND

    APPROXIMATE VENT PIPE WITH 15FT RADIUS SETBACK

    PL APPROXIMATE EXISTING PROPERTY LINE

    PROPOSED RACK - (2) VERTICAL ROWS OF 9 MODULES

    MV MV MV PROPOSED UNDERGROUND MEDIUM VOLTAGE CIRCUIT

    APPROXIMATEEXISTING WELL

    LOCATION,SETBACK TBD

    TRANSITION FROMABOVE GROUND TO

    UNDERGROUND OFF OFTHE LANDFILL

    OE OE OE PROPOSED OVERHEAD ELECTRIC CIRCUIT

    PROPOSED PV ARRAY

    AC AC AC PROPOSED LV ABOVE GROUND ELECTRIC CIRCUIT

    UG UG UG PROPOSED LV UNDERGROUND ELECTRIC CIRCUIT

    LINE EXTENSION BYGROSOLAR

    APPROXIMATEEXISTING POLE, RISERPOLE, GENERATORISOLATION SWITCH

    NEW METER POLE,NATIONAL GRID METER