Transcript
Page 1: Smart Air Hood™ Balancing Instrument: Series SAH

SMART Air Hood™Balancing Instrument:

“A Better Way to Air Balance”

T h e m a t e r i a l s i n c l u d e d i n t h i s c o m p i l a t i o n a r e f o r t h e u s e o f D w y e r I n s t r u m e n t s , I n c . p o t e n t i a l c u s t o m e r s a n d c u r r e n t e m p l o y e e s a s a r e s o u r c e o n l y . T h e y m a y n o t b e r e p r o d u c e d , p u b l i s h e d , o r t r a n s m i t t e d e l e c t r o n i c a l l y f o r c o m m e r c i a l p u r p o s e s . F u r t h e r m o r e , t h e C o m p a n y ’ s n a m e , l i k e n e s s ,

p r o d u c t n a m e s , a n d l o g o s , i n c l u d e d w i t h i n t h e s e c o m p i l a t i o n s m a y n o t b e u s e d w i t h o u t s p e c i fi c , w r i t t e n p r i o r p e r m i s s i o n f r o m D w y e r I n s t r u m e n t s , I n c . © C o p y r i g h t 2 0 1 6 D w y e r I n s t r u m e n t s , I n c .

Page 2: Smart Air Hood™ Balancing Instrument: Series SAH

Testing and Balancing Using today’s Air Flow Capture Hoods

• A recent independent survey of HVAC contractors revealed:

50% were not satisfied with air flow measurement and recording 37% not satisfied with set up and time to complete the job 87% were not satisfied adjusting air flow 62% not satisfied with how air flow is balanced

• Poor accuracy leads to higher energy costs.• Dwyer decided to take action!!

• Started by thoroughly testing todays air flow capture hoods in Dwyer’s custom in-house laboratory

Page 3: Smart Air Hood™ Balancing Instrument: Series SAH

Laboratory Specifications

First issue discovered:• Diffusers are the primary source

of error!

Action taken:• To build a mobile software application to

to calibrate various diffuser types

Lab Findings

Page 4: Smart Air Hood™ Balancing Instrument: Series SAH

Flow Through a Conventional Hood compared to a Quad Flow Hood Compared Designs using

Computational Flow Dynamics (CFD)

CFD models lead to a breakthroughTraditional Air Flow HoodDwyer’s Quad Flow Technology

Page 5: Smart Air Hood™ Balancing Instrument: Series SAH

Flow Through a Conventional Hood compared to a Quad Flow Hood

CFD models lead to a breakthrough

Compared Designs using Computational Flow Dynamics (CFD)

Traditional Air Flow HoodDwyer’s Quad Flow Technology

Page 6: Smart Air Hood™ Balancing Instrument: Series SAH

Supply Diffuser Library

Step-down Plaque

Directional2-way

Step-down3-cone

Directional1-way

Step-down2-cone

DirectionalModular-core

Perforated4-way Curved

Perforated Filtered4-way

Lab Tested Dwyer Diffuser Library

Page 7: Smart Air Hood™ Balancing Instrument: Series SAH

A Better Way to Air Balance

The SMART Air Hood™ Balancing Instrument improves the

balancing process

Page 8: Smart Air Hood™ Balancing Instrument: Series SAH

Proportional Balancing Review

• Proportional balancing is an iterative process based on estimating and sometimes guessing.

• Experienced technicians attempt to balance an HVAC system within +/-10% (in most scenarios).

• Experience and skill become critical to reducing the number of iterations for proportional balancing.

Traditional Proportional Balancing

Page 9: Smart Air Hood™ Balancing Instrument: Series SAH

• Predictive Balancing is deterministic!• There are a known number of steps • PredictAir Software Application

“predicts” where and how to adjust the dampers to accurately balance the system.

ReviewPredictive BalancingAd

just

Term

inal

2

Adjus

t Te

rmina

l 3

Adjus

t Te

rmina

l 4

Page 10: Smart Air Hood™ Balancing Instrument: Series SAH

• Smart Air Hood™ Balancing Instrument– Light-weight and maneuverable (< 6 lbs.)– Ergonomic, less muscle strain– Single Tech can operate– Quad Flow Design Technology

• Minimizes Back-Pressure error• Handheld Interface– Wi-Fi Direct with strong antenna (up to 200 yards)– Diffuser library in the PredictAir™ software

application– Predictive Balancing

SAH Key Features

Page 11: Smart Air Hood™ Balancing Instrument: Series SAH

• Accuracy – Calibrated for diffuser type in the library– Accuracy is ± 3% for any diffuser in the library

• Always operational– Lithium rechargeable battery– 4 AA backups

• Annual Calibration – easy and fast– Snap off Quad Flow sensing grids/ sensor and return – Snap on another recalibrated Quad Flow sensing grid and

sensor, no down time

SAH Key Features

Page 12: Smart Air Hood™ Balancing Instrument: Series SAH

• HVAC Contractors, specifically air balancing technicians, need a more accurate and efficient tool for air balancing.

• The Dwyer SMART Air Hood™ provides better:• Accuracy, mobility, efficiency, ease of balancing, and reporting

compared to other air flow hood’s currently on the market.

• Dwyer offers a differentiated technology, with the Quad Flow Design and the Predictive Balancing system.

• Proven Results: Saves Time and Money!

SAH Value Proposition

Page 13: Smart Air Hood™ Balancing Instrument: Series SAH

Yo u c a n fi n d m o r e i n f o r m a t i o n o n t h i s p r o d u c t b y v i s i t i n g o u r w e b s i t e D w y e r H o o d . c o m

F o r a n y t e c h n i c a l q u e s t i o n s y o u m a y h a v e , w e h a v e s e v e r a l t e c h n i c a l s u p p o r t e n g i n e e r s a v a i l a b l e b y p h o n e o r e m a i l a t :

( 2 1 9 ) 8 7 9 - 8 8 6 8 e x t . 4 0 2 Te c h @ d w y e r m a i l . c o m

To r e q u e s t a q u o t e o r p l a c e a n o r d e r , y o u c a n c o n t a c t o n e o f o u r c u s t o m e r s e r v i c e r e p r e s e n t a t i v e s a t :

( 2 1 9 ) 8 7 9 - 8 8 6 8 e x t . 6 5 6 Q u o t e s @ d w y e r m a i l . c o m O r d e r s @ d w y e r m a i l . c o m

Additional Information