SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt2
TYPICAL APPLICATIONS
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt3
Typical applicationsDesigned for mission critical applications, with highest levels of protection and reliability
Data centers Infrastructure
Medical equipments& healthcare
facilities
Security system
Transportation Finance institution
SG-CE Series Pure Pulse®
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt4
CHARACTERISTICS
&
PERFORMANCES
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt5
Product rangeCE Marked, 3x380/400/415V In & Out, 50/60Hz
60 – 80 kVA
100 – 120 kVA
UPS SG-CE Series 60kVA PurePulse® 54kW
UPS SG-CE Series 80kVA PurePulse® 72kW
UPS SG-CE Series 100kVA PurePulse® 90kW
UPS SG-CE Series 120kVA PurePulse® 108kW
IGBT rectifier
IGBT rectifier
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt6
Double conversion technologyDesigned for Mission Critical Applications
True On-Line Double Conversion VFI technology
Voltage and Frequency Independent
Inverter output transformer for load galvanic separation
Inverter
DC
Battery bank
AC
AC
DC
Static bypass
Rectifier
Bypass supply
LoadRectifier
supply
SG CE classification: VFI – SSS – 111VFI Voltage & Frequency Independent
Frequency Converter operation available
SS Output voltage THD < 8% for all loadsTHDv < 1.5% linear loadsTHDv < 3%non-linear loads
111 Class 1 performance Exceeding Class 1‘’Best in Class’’ dynamic response:+/- 3% at load step: 0-100%-0+/- 2% at load step: 0-50%-0
Class 1
SG-CE Series
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt7
UPS configurationDouble conversion with inverter output isolation transformer
Double conversion (VFI) technology with output isolation transformer Automatic bypass for overloads, short circuit and UPS disturbances
conditions Manual bypass for UPS maintenance operations without load
interruption Protection safety devices integrated
- back feed protection K6 standard- battery contactor K3 standard
RECTIFIER
BATTERY
SSM
INVERTER
LOA
DS
Q1
Q2
Q4
K3
K6
K7
MANUAL BYPASS
AUTOMATIC BYPASSIN
PU
T M
AIN
S
INVERTERTRANSFORMER
RECTIFIER
BATTERY
SSM
INVERTER
LOA
DS
Q1
Q2
Q4
K3
K6
K7
MANUAL BYPASS
AUTOMATIC BYPASSIN
PU
T M
AIN
S
INVERTERTRANSFORMER
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt8
Compact designTrue front access for operation and maintenance, saving installation space
154 W/154 W/
UPS1.600
835
850
Footprint SG-CE 120kVAUPS : 0.835 x 0.850 = 0.70 sqmOperational : 0.835 x 1.600 = 1.33 sqm
Reduced footprint Compact design saving space in
installation- 60-80 kVA:650 x 850 x 1900 mm- 100-120 kVA: 835 x 850 x 1900 mm - EMI cabinet:350 x 850 x 1900 mm
Easier to handle in narrow space
True front access Installation against a wall More space available for other
equipments
Reduced weight Easier to handle into installation site
(e.g. transportation through floors by lift)
Reduced installation time and cost
1900
650-835
850
154 kW/m2
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt9
Highest UPS output power capabilityCapability to supply Inductive, Resistive and Capacitive loads
Full range power capability Designed to supply real power for
any type of application - inductive loads- resistive loads- capacitive loads
No over-sizing required to supply resistive and capacitive loads
Suitable for modern power supply
application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1
I.e. SG-CE 120kVA load capabilities:
Inductive load PF=0.9 108 kW / 120 kVA
Resistive load PF=1 108 kW / 108 kVA
Capacitive load PF=0.9 108 kW / 120 kVA
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt10
Input rectifier performances Wide input window to preserve battery autonomy and lifetime
Input voltage
Inp
ut
freq
uen
cy
400V +15%-15%
+10%
-10%
50 Hz
Input window
Soft start
100%
0%
UPS input current
time
Wide input voltage and frequency windows
Limited use of battery Preserve battery autonomy for real
input mains failures Increase battery lifetime
Soft start Rectifier can be activated gradually,
controlling the input current Preventing instable situation for
GenSet Avoids false trip of upfront
protection devices Sequential softstart for parallel UPS
UPS 1 UPS 2
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt11
Backfeed protection IEC 62040-1 : ……“For fixed installation UPS, backfeed protection may be provided internally or externally to the UPS in the a.c. input line”
Inverter
DC
Battery bank
AC
AC
DC
static bypass
Rectifier
Backfeed contactor
Inputmains
Load
preventing feedback to the mains from the inverter in case of mains failure and a fault in the bypass
circuit
Standard feature inside UPS cabinet No additional cost required No addition installation required
Fully compliant with IEC 62040-1 Compliance to UPS installation safety requirements
Safer operating condition Safer operation for end users and
service engineers
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt12
IGBT technology for clean input Pure Pulse® configuration for highest input performances
UPS input performances Total Current Harmonic Distortion THDi=2% UPS input power factor: 0.99
Constant behavior at all loads Negligible harmonics contents at full and
partial loads
Benefit on input mains Saving in the sizing of upfront equipments
e.g. GenSet, cablings, circuit breakers, … No disturbances to nearby equipment Saving cost due to additional filters
PurePulse® technology for IGBT rectifier
Total Input Harmonic Distortion
Load
0%
1%
2%
3%
4%
5%
0% 20% 40% 60% 80% 100%
TH
Di
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt13
Perfect integration with GenSetNo GenSet oversizing required
GenSet integration
Example
Load 120 kVA; PF=0.8; 96 kWUPS SG 120 kVA Pure Pulse®;
input PF = 0.99
GenSet data reactance subtr. X“d=12%
GenSet size min. size required 132 kVA
GenSet/UPS = 132/120 = 1.1
Compatible with GenSet designSaving GenSet size
(suggested GenSet vs. UPS ratio ~ 1.1) Reducing GenSet installation spaceSaving GenSet investment
GenSet system integrationGenSet integration via Customer
Interface (dedicated auxiliary contact)Programmable functions based on
GenSet working condition (Gen on/off)
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt14
Superior Battery Management Safe and protected battery management to preserve investment and UPS reliability
Flexible applications Different battery technologies applicable: PB sealed (VRLA) - PB vented – NiCd Wide autonomy range: few minutes …... hours
User friendly information Prediction of true back-up time, based
on load status Alarm for “stop operation” to prevent
any unknown shut-down
Monitoring and control Battery test (programmable or manual) ; preserve UPS system reliability Battery earth fault detection; safer operation for service engineer & end user
Charging voltage = f (battery temperature)
2.18
2.21
2.24
2.27
2.30
2.33
2.36
0 5 10 15 20 25 30 35 40
Battery temperature [°C]
Vo
lt p
er c
ell
Voltage temperature compensation
V
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt15
No output voltage distortion with linear and non-linear loads Voltage distortion
- linear loads: THDv <1.5%- non-linear loads: THDv < 3%
Enhanced customer productivity Improved quality of application, reducing stress for loads supplied Increased uptime and MTBF of customer Reduced service intervention
(e.g. medical applications: ~60% labor hour & spare parts
reduction)
Output voltage with non-linear load
Output voltage with linear + non-linear load
No output voltage distortion Best in class inoutput dynamic stiffness
output voltage
output voltage
current
current
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt16
Medical scanner - dynamic current absorbtion
Best in class in output voltage variation with load steps:Static : < + 1%Dynamic at load steps 0-50-0%: < + 2%Dynamic at load steps 0-100-0% :
< + 3%
Enhanced customer unit productivityImproved quality of application
(i.e. medical images)Capability to supply critical loads with
high and fast loads steps (pulsating loads) Increased uptime and MTBF of customerReduced service intervention
1 ms
Output Dynamic Stiffness Best in class inoutput dynamic stiffness
Voltage variation at 0–100% load step
load step 0-100%output voltage
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt17
Back lit Graphic Display (LCD) Multilanguage communication
interface:English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch
Synoptic diagram indicating UPS status Command keys and parameters setting UPS status control LED
Control panel Easy and intuitive interface
LED - redStop Operation
LED - yellowAlarm
LED - greenOperation
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt18
EFFICIENCY
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt19
High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design
High efficiency performances at any load
High efficiency at full and partial loads for real benefit in operating conditions
Energy cost savingReduced cost of customer equipment
operation at all loads
Air conditioning cost savingReducing size and cost of air condition
systemReducing consumption and related
operating cost
SG CE PurePulse® rectifier – Efficiency
0%
20%
40%
60%
80%
92%100%
10% 25% 50% 75% 100%
LoadEffi
cie
ncy %
Typical Operation
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt20
Normal modeThe output voltage is newly
generated, independently from the input voltage
Heat losses are present in rectifier and inverter
Super Eco ModeLoad is supplied via the bypassUPS rectifier keeps the battery
chargedUPS inverter switched off
(no heat losses)
Super Eco Mode - functionalityImproving UPS efficiency
Super Eco Mode
Normal mode
Inverter
DC
Battery bank
AC
AC
DC
Static bypass
Rectifier
Bypass supply
LoadRectifier
supply
Inverter
DC
Battery bank
AC
AC
DC
Static bypass
Rectifier
Bypass supply
LoadRectifier
supply
Transf.
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt21
High efficiency: 98%prevents heat lossessaving customer utility bill
Fast transfer time to inverter: <2 ms Guaranteed safe energy for the application
Configurable according to load requirementAdjustable bypass supply tolerance
- voltage: +/- 10% (adjustable)- frequency: +/- 5% (adjustable)
Super Eco Mode - benefitHigh efficiency, preserving protection to critical load
Bypasson/off
Invertercurrent
Inverter
control
Output voltage
< 2ms
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt22
RPA
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt23
Redundant Parallel Architecture True redundancy with no single point of failure
rectifier bypass rectifierbypass
critical load
DC
AC
AC
DC
battery
Input mains
DC
AC
AC
DC
battery
Modular designFuture system expansionSaving investment
True redundancyNo single point of failureDecentralized bypassDistributed parallel management
system
Increased system reliabilitySafe and reliable power supply for
“mission critical applications”Increase productivityTrue redundancy with no single
point of failure
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt24
Configurable up to 6 units in parallel
Future expansion Safe and reliable power supplyRedundant Communication Bus
Easy to install and maintainEasy system
upgrade/downgradeMaintenance operation without
load interruption critical load
utility supply
Redundant Parallel ArchitectureIncrease system reliability for Mission Critical Applications
redundantcommunicationbuses
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt25
EMC
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt26
EMC - Electro Magnetic CompatibilityIEC 62040-2 standard defines the limits of maximum allowable levels of emission of electromagnetic disturbances for UPS systems
EmissionAny electronic devices emits electromagnetic disturbances - radio frequency waves - through:- cables (CE: conducted emissions)- air (RE: radiated emissions)
ImmunityAll electronic equipment is sensitive for electromagnetic waves.These waves can disturb the functions of these equipments
Electro Magnetic CompatibilityDisturbances tolerance among different types of equipment when running in the same environment.
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt27
EMC - Immunity
ImmunitySG-CE products design exceed IEC 62040-2 C3 level for immunity, i.e. can withstand possible disturbances and noise without affecting standard working conditions
ImmunitySG-CE
immunity levelIEC requirements
ESD 15kV (air)
8kV (contact)8kV (air)
4kV (contact)
Surge2kV line to line
4kV line to earth1kV line to line
2kV line to earth
Burst 4kV @5kHz 2kV @5kHz
RF common mode (1kHz) 10V 10V
Surge suppressors mounted standard in UPS cabinet
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt28
EMC Category C2 (Class A), optional feature* Compensation of radio-frequency emission to avoid distrurbances on nearby equipments
No interference with other equipments Avoid any interferences with critical applications sensitive to radio frequency emission (e.g. telecom, broadcasting, …) No additional investment required for EMC investigation.
Protected unit quality enhancement Increased quality and productivity
(e.g. Image quality in medical application)
*Additional EMC cabinet required
Standard limit
Measurement data
Standard limit
Measurement data
SGSE_100-120_S1_UPS+EMC_GE_02
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt29
SERVICEABILITY
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt30
Designed for serviceabilitySaving time and cost in service
Easy maintenance intervententionReducing time and cost on maintenance intervention Reducing down-time, increasing availability
Easy access to inverter/rectifier/bypass bridge
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt31
POWER QUALITY
SYSTEMS
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt32
Power Quality Systems Integretion with other Power Quality euipments for Mission Critical Applications
IS
M_C
abin
et_G
E_0
1
UPS-A
UPS-B
Battery-A
Battery-B
ISM
STS-A
STS-B
Load-A
Load-B
Input
mains
Input
mains
UPS: Uninterruptible Power SupplyISM:Intelligent Synchronization ModuleSTS: Static Transfer Switch
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt33
INTEGRATION WITH BMS
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt34
Customer interfaceEasy integration with Building Management System (BMS)
Customer interfaceUPS supervision capability1x RS232 Serial Communication Port6 programmable potential free alarm
contacts: - D plug - Terminals blocks
1x Emergency Power OFF contact1x Gen-ON Input contact1x Control Input contact
Additional interface:SNMP Interface Card
(10/100Mbps auto-select)MODBUS RTU Interface (RS232 or
RS485)
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt35
CONNECTIVITY
SG-CE Series 60-120 kVA PurePulse®Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt36
Data Acquisition
Communication
Medium
User Interfac
e
IRISInfrastructur
e
SNMP/Modem/GPRS topologies available
Flexible, safe and customer-friendly solution for remote monitoring
Secure communication via: e-mail, SMS, faxGPRSWeb/PDA
GE Power Diagnostics Remote monitoring and diagnostics solution
SG-CE Series 60-120 kVA PurePulse®Sales presentation