    SDPN16 – thermosyphon system

    SDPN16

    Technical data

    Pressure Up to 16 bar

    Temperature -60 °C to 200 °C

    Total volume 8 litres

    Working volume 1.3 litres

    Cooling capacity without cooling water 0.3 kW

    Cooling capacity, natural circulation 1.2 kW

    Cooling capacity, forced circulation 2.5 kW

    Design to PED 2014 / 68 / EU

    Business type Standard (KSB EasySelect)

    Application: mode of operation to API Plan 52 or 53A

    Configurable components:

    A1 Pressure gauge connection

    A2 Level switch connection

    A3 Pressurised gas connection

    A4 Venting unit

    A5 Safety valve connection

    A6 Holder for refill unit

    A7 Drain unit connection

    A8 Thermometer connection

    1 General description

    Thermosyphon system for use with pressurised barrier

    fluid or unpressurised buffer fluid (Plan 53A and 52).

    A cooling coil is integrated in the system and can be

    connected as an option. A large range of components

    can be configured in addition.

    2 Safety

    Used for applications where leakage of the fluid

    handled to atmosphere must be minimised, collected

    or completely ruled out.

    3 Use

    For double mechanical seals with pressurised barrier

    fluid or unpressurised buffer fluid. Depending on the

    application, the buffer fluid or barrier fluid pressure

    is either lower or higher than the pressure in the

    pump’s seal chamber.

    4 Longer seal life

    The system flushes the space between the seals with

    a clean buffer fluid or barrier fluid. This carries the

    heat away from this area, thus increasing the seal’s

    service life.