PERFORM REPAIRS AND APPLY A REHABILITATIVE COATING TO EXISTING METAL ROOFS ON BUILDING 11, 12 AND 14.REPLACE ROOFING ON MEDIA CENTER CANOPIES.
MR. CARL G. PERSIS
MRS. IDA D. WRIGHT
MR. RUBEN COLON
MRS. LINDA CUTHBERT
MS. JAMIE M. HAYNES
MR. JAMES T. RUSSELL
SCHOOL BOARD
MEMBERS
CHAIRMAN
VICE CHAIRMAN
MEMBER
MEMBER
MEMBER
SUPERINTENDENT
A. SURVEY PARCEL ID N/A
B. LEGAL DESCRIPTION
C. OCCUPANCY TYPE
D. CONSTRUCTION TYPE
E. RISK CATEGORY
F. AUTOMATIC SPRINKLER
G. BUILDING AREA
H. BUILDING HEIGHT
I. OCCUPANT LOAD
LOCATION MAP
ENGINEERS & CONSULTANTS
THE SCHOOL BOARD OF VOLUSIA
COUNTY FLORIDA
200 North Clara Avenue
Deland, Florida 32720
VCS Project NO. 184676
730 S PARSONS AVE
DELAND, FL 32720
COAT ROOF BLDGS 11 - 14
AND REROOF MEDIA CENTER
CANOPIES
EDITH I. STARKE ELEMENTARY SCHOOL
Architect's Statement of ComplianceTo the best of my knowledge, these drawings and the project manual are complete and comply withthe Florida Building Code.
DISCIPLINE : ARCHITECTURALFIRM NAME: GALE ASSOCIATES INCADDRESS: 160 N. WESTMONTE DRIVE SUITE 1200ADDRESS: ALTAMONTE SPRINGS, FL 32714CONTACT PHONE NUMBER: 407-599-7031PROJECT MANAGER: ALAN S. CRAIGOEMAIL ADDRESS: [email protected]
Gale Associates, Inc.
Engineers Architects Planners
160 N. Westmonte Drive
Altamonte Springs, FL 32714
P 407.599.7031 F 407.599.7077 www.gainc.com
Gale Associates (South), Inc. FL CA Lic. No: 6114
Boston Baltimore Orlando Hartford
G001 COVER SHEET
G002STANDARD LEGEND, SYMBOLS AND GENERAL NOTES
A101 ROOF PLANS - BLDGS 11 AND 12
A102 ROOF PLAN - BLDG 14
A103 ROOF AND FRAMING PLANS - MEDIA CENTER CANOPIES
ROOF EDGE GUTTER WITH DOWNSPOUT GUTTER EXPANSION JOINT RIDGE / HIP EXPANSION JOINT FAN VENT GOOSENECK J-VENT RELIEF VENT VENT PIPE CONDUIT PENETRATION STRUCTURAL SLOPE TAPERED SLOPE
AutoCAD SHX Text
STANDARD LEGEND
AutoCAD SHX Text
NOTE: NOT ALL SYMBOLS NECESSARILY USED
AutoCAD SHX Text
STANDARD SYMBOLS
AutoCAD SHX Text
NOTE: NOT ALL SYMBOLS NECESSARILY USED
AutoCAD SHX Text
DETAIL IDENTIFIER
AutoCAD SHX Text
EX
AutoCAD SHX Text
1
AutoCAD SHX Text
A500
AutoCAD SHX Text
EXISTING CONDITION IDENTIFIER
AutoCAD SHX Text
SHEET WHERE DETAIL IS SHOWN
AutoCAD SHX Text
DETAIL INDICATOR
AutoCAD SHX Text
SECTION IDENTIFIER
AutoCAD SHX Text
EX
AutoCAD SHX Text
EXISTING CONDITION IDENTIFIER
AutoCAD SHX Text
SHEET WHERE SECTION IS SHOWN
AutoCAD SHX Text
SECTION INDICATOR
AutoCAD SHX Text
F
AutoCAD SHX Text
V
AutoCAD SHX Text
G
AutoCAD SHX Text
J
AutoCAD SHX Text
1
AutoCAD SHX Text
A500
AutoCAD SHX Text
ELEVATION IDENTIFIER
AutoCAD SHX Text
SHEET WHERE ELEVATION IS SHOWN
AutoCAD SHX Text
ELEVATION INDICATOR
AutoCAD SHX Text
STANDARD HATCH PATTERNS
AutoCAD SHX Text
NOTE: NOT ALL HATCH PATTERNS NECESSARILY USED
AutoCAD SHX Text
BATT INSULATION
AutoCAD SHX Text
CELLULAR FOAM INSULATION
AutoCAD SHX Text
CEMENTITIOUS WOOD FIBERBOARD
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
FIBERGLASS INSULATION
AutoCAD SHX Text
GYPSUM
AutoCAD SHX Text
ISOCYANURATE INSULATION
AutoCAD SHX Text
STEEL
AutoCAD SHX Text
WOOD FIBERBOARD
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
DEMOLITION NOTES 1.THE INFORMATION SHOWN ON THE DRAWINGS HAS BEEN COMPILED FROM VARIOUS SOURCES, AND MAY THE INFORMATION SHOWN ON THE DRAWINGS HAS BEEN COMPILED FROM VARIOUS SOURCES, AND MAY NOT REFLECT THE ACTUAL CONDITIONS AT THE TIME OF CONSTRUCTION. 2.THE BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL SCHEDULE AND THE BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL SCHEDULE AND EXECUTE WORK TO AVOID INTERRUPTIONS TO BUILDING OPERATIONS. 3.CONTRACTOR SETUP LOCATIONS SHALL BE AS INDICATED BY THE OWNER DURING THE PRECONSTRUCTION CONTRACTOR SETUP LOCATIONS SHALL BE AS INDICATED BY THE OWNER DURING THE PRECONSTRUCTION MEETING. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COVERING ALL INTERIOR ITEMS INCLUDING FLOORS AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR COVERING ALL INTERIOR ITEMS INCLUDING FLOORS AND EQUIPMENT PRIOR TO DEMOLITION. ONCE REMOVAL IS COMPLETE FOR THE DAY, THE PLASTIC COVERINGS SHALL BE REMOVED AND THE INTERIOR AREAS CLEANED. CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO, SWEEPING OF FLOORS AND DUST REMOVAL FROM THE TOPS OF LIGHT FIXTURES AND EQUIPMENT WHERE ACCESSIBLE. 5.THE CONTRACTOR SHALL REPORT DETERIORATED OR UNSUITABLE ROOF DECK OR SUBSTRATE THE CONTRACTOR SHALL REPORT DETERIORATED OR UNSUITABLE ROOF DECK OR SUBSTRATE COMPONENTS TO THE OWNER PRIOR TO PERFORMING ROOFING INSTALLATION WORK. 6.REMOVE AND DISPOSE OF EXISTING ROOF SYSTEM AND ALL ASSOCIATED MATERIALS DOWN TO THE REMOVE AND DISPOSE OF EXISTING ROOF SYSTEM AND ALL ASSOCIATED MATERIALS DOWN TO THE STRUCTURAL DECK UNLESS OTHERWISE INDICATED ON THE DETAIL DRAWINGS TO REMAIN. REMOVE AND DISPOSE OF ALL ITEMS TO INCLUDE DRAINS, WOOD BLOCKING AND APPURTENANCES SCHEDULED TO BE REMOVED. 7.PROVIDE TEMPORARY OVERHEAD PROTECTION AT THE MAIN ENTRANCE AND AT OTHER LOCATIONS AS PROVIDE TEMPORARY OVERHEAD PROTECTION AT THE MAIN ENTRANCE AND AT OTHER LOCATIONS AS NECESSARY TO PROVIDE UNINTERRUPTED ACCESS TO BUILDING. 8.REMOVALS SHALL BE PERFORMED IN ACCORDANCE WITH THE SUBMITTED AND APPROVED REMOVAL PLAN, REMOVALS SHALL BE PERFORMED IN ACCORDANCE WITH THE SUBMITTED AND APPROVED REMOVAL PLAN, THE DETAIL DRAWINGS AND SPECIFICATIONS. INSTALLATION NOTES 1.FOR THE SAKE OF CLARITY, EACH INDIVIDUAL DETAIL ON THE ROOF PLANS HAS NOT BEEN INDICATED. FOR THE SAKE OF CLARITY, EACH INDIVIDUAL DETAIL ON THE ROOF PLANS HAS NOT BEEN INDICATED. EXISTING AND NEW DETAILS HAVE BEEN INDICATED FOR TYPICAL COMPONENTS AT RANDOM LOCATIONS. 2.COMPONENTS SHOWN ON THE DETAIL DRAWINGS SHALL BE NEW UNLESS SPECIFICALLY INDICATED AS COMPONENTS SHOWN ON THE DETAIL DRAWINGS SHALL BE NEW UNLESS SPECIFICALLY INDICATED AS EXISTING. 3.ITEMS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS ITEMS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT. 4.FOR THE SAKE OF CLARITY, SECUREMENT FASTENERS ARE NOT SHOWN ON THE DRAWING. REFER TO FOR THE SAKE OF CLARITY, SECUREMENT FASTENERS ARE NOT SHOWN ON THE DRAWING. REFER TO SPECIFICATIONS FOR FASTENER TYPES AND SPACING. 5.ANY DISCREPANCIES ON THE DRAWINGS NOTED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ANY DISCREPANCIES ON THE DRAWINGS NOTED BY THE CONTRACTOR SHALL BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO BID SUBMISSIOIN. 6.ITEMS OF CONSTRUCTION SHALL BE 100% WATERTIGHT ON THE SAME DAY OF WORK. [PHASED ITEMS OF CONSTRUCTION SHALL BE 100% WATERTIGHT ON THE SAME DAY OF WORK. [PHASED CONSTRUCTION MUST BE APPROVED BY THE OWNER PRIOR TO CONSTRUCTION.] 7.DETAILS NOT DEPICTED SHALL BE CONSTRUCTED IN A MANNER CONSISTENT WITH THE DETAIL DRAWINGS. DETAILS NOT DEPICTED SHALL BE CONSTRUCTED IN A MANNER CONSISTENT WITH THE DETAIL DRAWINGS. 8.IF THERE IS A POTENTIAL HAZARDOUS MATERIAL ENCOUNTERED DURING THE COURSE OF WORK THAT IS IF THERE IS A POTENTIAL HAZARDOUS MATERIAL ENCOUNTERED DURING THE COURSE OF WORK THAT IS NOT IDENTIFIED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR WILL STOP WORK IMMEDIATELY AND CONTACT THE OWNER WHO IS TO MAKE A DETERMINATION IF THE MATERIAL IS HAZARDOUS. 9.ALL DUMPSTERS MUST BE AT LEAST 15 FEET FROM THE BUILDING UNLESS EMPTIED AT THE END OF EACH ALL DUMPSTERS MUST BE AT LEAST 15 FEET FROM THE BUILDING UNLESS EMPTIED AT THE END OF EACH WORK DAY. 10.MATERIALS MAY NOT BE STORED CLOSER THAN 15 FEET FROM BUILDINGS AND MAY NOT BE PLACED IN MATERIALS MAY NOT BE STORED CLOSER THAN 15 FEET FROM BUILDINGS AND MAY NOT BE PLACED IN FRONT OF EXITS OR ANY FIRE PROTECTION EQUIPMENT. REFUELING OF GASOLINE POWERED EQUIPMENT WILL NOT BE PERMITTED ON THE ROOF. GASOLINE MUST BE STORED IN UL LISTED AND APPROVED CONTAINERS. 11.DISCONNECT, REMOVE, STORE, PROTECT AND REINSTALL EXISTING ROOFTOP EQUIPMENT AND ASSOCIATED DISCONNECT, REMOVE, STORE, PROTECT AND REINSTALL EXISTING ROOFTOP EQUIPMENT AND ASSOCIATED MECHANICAL/ELECTRICAL PENETRATIONS AND CONDUIT TO PROPERLY INSTALL REPLACEMENT ROOF SYSTEMS AND PROVIDE MINIMUM SPECIFIED FLASHING HEIGHTS. THE CONTRACTOR SHALL "LOCK-OUT" ALL MECHANICAL/ELECTRICAL EQUIPMENT, INCLUDING HVAC EQUIPMENT, PRIOR TO INITIATING WORK. METAL FABRICATION NOTES 1.FILE SMOOTH ALL EXPOSED SHARP EDGES. FILE SMOOTH ALL EXPOSED SHARP EDGES. 2.FABRICATE METAL TRANSITIONS IN ONE-PIECE CONSTRUCTION. FABRICATE METAL TRANSITIONS IN ONE-PIECE CONSTRUCTION. 3.SOLDER OR LOCK AND SEAL ALL JOINTS SOLID TO MAKE WATERTIGHT. SOLDER OR LOCK AND SEAL ALL JOINTS SOLID TO MAKE WATERTIGHT. 4.FIELD VERIFY ALL DIMENSIONS.FIELD VERIFY ALL DIMENSIONS.
AutoCAD SHX Text
WIND UPLIFT INFORMATION
AutoCAD SHX Text
SPECIFIED PER FLORIDA BUILDING CODE (2017) CH. 16 AND IN ACCORDANCE WITH ASCE 7-10
EXISTING 3/4" PLYWOOD DECK, REMOVE AND REPLACE WHERE DETERIORATED TO MATCH EXISTING (FIELD VERIFY THICKNESS)
AutoCAD SHX Text
EXISTING BASE SHEET, TO BE REMOVED
AutoCAD SHX Text
EXISTING 2-PLY MODIFIED BITUMEN ROOFING, TO BE REMOVED
AutoCAD SHX Text
EXISTING SHAPED 3X6 WOOD FRAMING, TO BE REMOVED AND REPLACED WHERE INDICATED, SEE SHEET A103
AutoCAD SHX Text
EXISTING 3/4" PLYWOOD DECK, REMOVE AND REPLACE WHERE DETERIORATED TO MATCH EXISTING (FIELD VERIFY THICKNESS)
AutoCAD SHX Text
1/2" GYPSUM COVERBOARD
AutoCAD SHX Text
SINGLE-PLY THERMOPLASTIC ROOF MEMBRANE, MECHANICALLY ATTACHED, SEE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3
AutoCAD SHX Text
A301
AutoCAD SHX Text
TYP. BASE FLASHING - CANOPY
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
4
AutoCAD SHX Text
A301
AutoCAD SHX Text
JOINT TREATMENT AT EDGE METAL
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
WALL SUBSTRATE
AutoCAD SHX Text
SINGLE-PLY ROOF MEMBRANE
AutoCAD SHX Text
MEMBRANE FLASHING
AutoCAD SHX Text
TERMINATION BAR
AutoCAD SHX Text
SINGLE-PLY ROOF MEMBRANE
AutoCAD SHX Text
FULLY HEAT WELDED LAP, TYP.
AutoCAD SHX Text
THERMOPLASTIC WALL FLASHING MEMBRANE
AutoCAD SHX Text
TURN ROOF MEMBRANE UP AGAINST BASE OF WALL AND SECURE WITH TERMINATION BAR AS SPECIFIED, SEE SECTION ABOVE
AutoCAD SHX Text
COVERBOARD
AutoCAD SHX Text
PLYWOOD DECK
AutoCAD SHX Text
COVERBOARD
AutoCAD SHX Text
SINGLE-PLY THERMOPLASTIC ROOF MEMBRANE
AutoCAD SHX Text
TURN ROOF MEMBRANE DOWN OVER WOOD BLOCKING (BEHIND EDGE METAL) AND SEAL EDGE OF MEMBRANE TO VERTICAL FACE AS SHOWN
AutoCAD SHX Text
THERMOPLASTIC CLAD EDGE METAL AS SPECIFIED, SEE
AutoCAD SHX Text
THERMOPLASTIC SINGLE-PLY ROOF MEMBRANE STRIPPING PLY FULLY HEAT WELDED OVER EDGE METAL DECK FLANGE
AutoCAD SHX Text
PLYWOOD DECK
AutoCAD SHX Text
EXISTING STANDING SEAM METAL ROOF SYSTEM (FABRAL SLIM SEAM OR SIMILAR), TO REMAIN
AutoCAD SHX Text
EXISTING STANDING SEAM METAL ROOF SYSTEM (FABRAL SLIM SEAM OR SIMILAR)
AutoCAD SHX Text
FLUID-APPLIED FINISH COATING SYSTEM OVER EXISTING METAL ROOF
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1
AutoCAD SHX Text
A301
AutoCAD SHX Text
ROOF SYSTEM
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
2
AutoCAD SHX Text
A301
AutoCAD SHX Text
ROOF SYSTEM
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
EXISTING STEEL DECK, TO REMAIN
AutoCAD SHX Text
EXISTING STEEL DECK
AutoCAD SHX Text
EXISTING ROOF SYSTEM
AutoCAD SHX Text
NEW ROOF SYSTEM
AutoCAD SHX Text
EXISTING ROOF SYSTEM
AutoCAD SHX Text
NEW ROOF SYSTEM
AutoCAD SHX Text
EXISTING 3X6 WOOD FRAMING, TO BE REMOVED AND REPLACED WHERE INDICATED, SEE SHEET A103
AutoCAD SHX Text
1A
AutoCAD SHX Text
A301
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
1A
AutoCAD SHX Text
A301
AutoCAD SHX Text
TYP. ROOF CONFIGURATION
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SINGLE-PLY THERMOPLASTIC ROOF MEMBRANE
AutoCAD SHX Text
COVERBOARD, LOCATE FASTENERS OVER EXISTING ROOF FRAMING LOCATIONS TO AVOID PENETRATING FASTENERS THROUGH FIELD OF ROOF DECK
AutoCAD SHX Text
INSTALL SINGLE PLY ROOFING SO MECHANICALLY ATTACHED LAPS OCCUR DIRECTLY OVER EXISTING WOOD ROOF FRAMING MEMBERS (FASTEN MEMBRANE TO EXISTING WOOD JOISTS, TYP.)
AutoCAD SHX Text
(MEDIA CENTER CANOPY)
AutoCAD SHX Text
(MEDIA CENTER CANOPY)
AutoCAD SHX Text
(BLDG 11, 12 AND 14)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
2A
AutoCAD SHX Text
A301
AutoCAD SHX Text
TYPICAL ROOF COATING
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
(BLDG 11, 12 AND 14)
AutoCAD SHX Text
APPLY FLUID-APPLIED FINISH COATING SYSTEM OVER EXISTING STANDING SEAM METAL ROOFING, TYP.
AutoCAD SHX Text
EXTEND FLUID-APPLIED FINISH COATING SYSTEM OVER EXISTING STANDING SEAM METAL FASCIA PANELS
AutoCAD SHX Text
DO NOT COAT NEW PRE-FINISHED DRIP EDGE METAL AND TRIM
AutoCAD SHX Text
BASE SCOPE: CLEAN EXISTING FLUSH : CLEAN EXISTING FLUSH SEAM GABLE WALL PANELS AND DO NOT APPLY NEW FINISH COAT. ALTERNATE: APPLY FLUID-APLIED : APPLY FLUID-APLIED FINISH COATING SYSTEM OVER EXISTING FLUSH SEAM GABLE WALL PANELS.
AutoCAD SHX Text
REMOVE AND REPLACE SEALANT AROUND PERIMETER OF LOUVERS, TYP.
AutoCAD SHX Text
EXISTING FELT PAPER UNDERLAYMENT, TO REMAIN
AutoCAD SHX Text
EXISTING FELT PAPER UNDERLAYMENT
AutoCAD SHX Text
WALL SUBSTRATE (VARIES)
AutoCAD SHX Text
BLOCKING AT EDGE
AutoCAD SHX Text
WOOD FASCIA
AutoCAD SHX Text
1
AutoCAD SHX Text
A505
AutoCAD SHX Text
4" WIDE THERMOPLASTIC MEMBRANE FLASHING STRIP HEAT WELDED IN PLACE OVER EDGE METAL SPLICE JOINT
AutoCAD SHX Text
2" WIDE ALUMINUM TAPE OVER EDGE METAL JOINT (BENEATH MEMBRANE JOINT FLASHING STRIP)
AutoCAD SHX Text
APPLY REINFORCED FLASHING GRADE ROOF COATING AROUND ROOF PENETRATIONS PRIOR TO APPLICATION OF FINISH COATING SYSTEM
AutoCAD SHX Text
EXISTING PLYWOOD DECK
AutoCAD SHX Text
EXISTING WOOD ROOF FRAMING
AutoCAD SHX Text
MASK OFF ALL AREAS TO ISOLATE SURFACES SCHEDULED TO RECEIVE COATINGS FROM THOSE NOT TO BE COATED, REFER TO DETAILS FOR EXTEND OF NEW COATING APPLICATION
FLUID-APPLIED FINISH COATING SYSTEM OVER ROOF AND FASCIA PANELS, SEE
AutoCAD SHX Text
EXISTING STANDING SEAM METAL ROOF PANELS
AutoCAD SHX Text
FLUID-APPLIED FINISH COATING SYSTEM, SEE
AutoCAD SHX Text
EXISTING STANDING SEAM METAL ROOF PANELS
AutoCAD SHX Text
FLUID-APPLIED FINISH COATING SYSTEM OVER ROOF PANELS AND FLASHINGS, SEE
AutoCAD SHX Text
APPLY FLASHING GRADE ROOF COATING TO SEAMS AND FASTENERS PRIOR TO APPLICATION OF FINISH COAT SYSTEM
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
6
AutoCAD SHX Text
A501
AutoCAD SHX Text
CANOPY-TO-WALL PANEL
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
24 GA. PRE-FINISHED GALVALUME METAL CANOPY FLASHING
AutoCAD SHX Text
24 GA. PRE-FINISHED GALVALUME METAL CANOPY FLASHING Z-CLEAT SET IN SEALANT AND FASTENED TO CANOPY TOP RIBS
AutoCAD SHX Text
EXISTING ALUMINUM WALKWAY CANOPY
AutoCAD SHX Text
EXISTING METAL FRAMING
AutoCAD SHX Text
EXISTING STEEL DECK
AutoCAD SHX Text
EXISTING METAL RIB COVER, REMOVE AND REINSTALL TO ACCOMMODATE WORK. APPLY FLASHING GRADE ROOF COATING TO SEAMS AND RIVETS PRIOR TO FINISH COAT
AutoCAD SHX Text
EXISTING METAL FASCIA PANELS, LIFT UP TO ACCOMMODATE REPAIRS THEN SET BACK IN PLACE, SEE
AutoCAD SHX Text
EXISTING PLYWOOD SHEATHING
AutoCAD SHX Text
REMOVE AND REPLACE PRE-FINISHED METAL DRIP EDGE AT ALL FASCIA/EAVE CONDITIONS (DO NOT APPLY FINISH COATING TO NEW PRE-FINISHED DRIP EDGE), SEE
AutoCAD SHX Text
EXISTING METAL FRAMING
AutoCAD SHX Text
EXISTING FELT UNDERLAYMENT
AutoCAD SHX Text
EXISTING ROOF FRAMING
AutoCAD SHX Text
EXISTING STEEL DECK
AutoCAD SHX Text
GUTTER AND DOWNSPOUT, SEE
AutoCAD SHX Text
EXISTING PLYWOOD SHEATHING
AutoCAD SHX Text
EXISTING METAL GABLE TRIM, EXTEND FINISH COAT OVER VERTICAL FACE AND STOP AT BOTTOM OF TRIM AS SHOWN
AutoCAD SHX Text
FLUID-APPLIED FINISH COATING SYSTEM, SEE
AutoCAD SHX Text
EXISTING STANDING SEAM METAL ROOF PANELS
AutoCAD SHX Text
EXISTING FLUSH SEAM METAL GABLE WALL PANELS (DO NOT COAT), FOR ALTERNATE SCOPE OF WORK REFER TO
AutoCAD SHX Text
EXISTING STEEL DECK
AutoCAD SHX Text
EXISTING PLYWOOD SHEATHING
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
3
AutoCAD SHX Text
A501
AutoCAD SHX Text
GUTTER @ RAKE EDGE
AutoCAD SHX Text
3" = 1'-0"
AutoCAD SHX Text
GUTTER AND DOWNSPOUT, SEE
AutoCAD SHX Text
EXISTING STANDING SEAM METAL ROOF PANELS
AutoCAD SHX Text
FLUID-APPLIED FINISH COATING SYSTEM, SEE
AutoCAD SHX Text
EXISTING STEEL DECK
AutoCAD SHX Text
2
AutoCAD SHX Text
A301
AutoCAD SHX Text
2
AutoCAD SHX Text
A301
AutoCAD SHX Text
2
AutoCAD SHX Text
A505
AutoCAD SHX Text
2
AutoCAD SHX Text
A301
AutoCAD SHX Text
2
AutoCAD SHX Text
A301
AutoCAD SHX Text
2
AutoCAD SHX Text
A301
AutoCAD SHX Text
6
AutoCAD SHX Text
A505
AutoCAD SHX Text
EXISTING STEEL DECK
AutoCAD SHX Text
EXISTING METAL FASCIA PANELS, TO REMAIN IN PLACE AT GUTTER EDGES, TYP. APPLY FLUID-APPLIED FINISH COATING SYSTEM TO FASCIA PANELS BENEATH GUTTER
AutoCAD SHX Text
EXISTING BRICK MASONRY VENEER
AutoCAD SHX Text
SELF-ADHERED MEMBRANE
AutoCAD SHX Text
6
AutoCAD SHX Text
A501
AutoCAD SHX Text
24 GA. PRE-FINISHED GALVALUME METAL SOFFIT TRIM, FASTEN TO UNDERSIDE OF EXISTING SOFFIT PANELS WITH CLOSED-END POP RIVETS AT " O.C., TYP.
AutoCAD SHX Text
STRIP IN GALVALUME METAL FLASHING AND EXPOSED FASTENERS WITH REINFORCED FLASHING GRADE ROOF COATING PRIOR TO FINISH COAT
AutoCAD SHX Text
GALVALUME METAL FLASHING AT GUTTER RAKE EDGE TRANSITION, CONFORM TO ROOF SLOPE
AutoCAD SHX Text
SECURE WITH THROUGH-BOLTS AND NUTS AT 12" O.C., SEAL OVER FASTENERS WITH FLASHING GRADE ROOF COATING PRIOR TO FINISH COAT
AutoCAD SHX Text
EXISTING METAL RIDGE CAP, SEAL LAP JOINTS/SEAMS AND EXPOSED FASTENERS WITH FLASHING GRADE ROOF COATING PRIOR TO APPLICATION OF FINISH COAT SYSTEM
AutoCAD SHX Text
EXISTING METAL DRIP EDGE
AutoCAD SHX Text
EXISTING EAVE FRAMING
AutoCAD SHX Text
EXISTING SOFFIT FRAMING
AutoCAD SHX Text
EXISTING METAL SOFFIT PANELS
AutoCAD SHX Text
EXISTING SOFFIT FRAMING
AutoCAD SHX Text
EXISTING METAL SOFFIT PANELS
AutoCAD SHX Text
EXISTING STEEL COLUMNS
AutoCAD SHX Text
EXISTING BRICK MASONRY COLUMN SURROUNDS
AutoCAD SHX Text
EXISTING ROOF FRAMING
AutoCAD SHX Text
EXISTING PLYWOOD SHEATHING
AutoCAD SHX Text
EXISTING FLUSH SEAM METAL GABLE WALL PANELS (DO NOT COAT), FOR ALTERNATE SCOPE OF WORK REFER TO
AutoCAD SHX Text
2A
AutoCAD SHX Text
A301
AutoCAD SHX Text
EXISTING FLUSH SEAM METAL GABLE WALL PANELS (DO NOT COAT), FOR ALTERNATE SCOPE OF WORK REFER TO
AutoCAD SHX Text
2A
AutoCAD SHX Text
A301
AutoCAD SHX Text
3
AutoCAD SHX Text
A505
AutoCAD SHX Text
SIM
AutoCAD SHX Text
2
AutoCAD SHX Text
A505
AutoCAD SHX Text
SIM
AutoCAD SHX Text
3
AutoCAD SHX Text
A505
AutoCAD SHX Text
16 GA. GALV. Z-FURRING, FASTEN THROUGH PANELS AND PLYWOOD TO EXISTING STEEL FRAMING WITH 1/4-14X2" HWH "BLAZER 3" SCREWS, 8" O.C. (MIN. 2 PER PANEL)
AutoCAD SHX Text
EXISTING METAL DRIP EDGE (TO REMAIN)
AutoCAD SHX Text
REMOVE AND REPLACE PRE-FINISHED METAL DRIP EDGE SOFFIT TRIM ALONG GUTTER EDGE FASCIA LOCATIONS, TYP. HOOK INTO EXISTING DRIP EDGE AND FASTEN TO UNDERSIDE OF EXISTING SOFFIT PANELS WITH CLOSED-END POP RIVETS @ 8" O.C.
AutoCAD SHX Text
24 GA. PRE-FINISHED GALVALUME GUTTER SKIRT CLOSURE METAL
AutoCAD SHX Text
24 GA. PRE-FINISHED GALVALUME GUTTER SKIRT METAL
AutoCAD SHX Text
2A
AutoCAD SHX Text
A301
AutoCAD SHX Text
24 GAGE PRE-FINISHED GALVALUME METAL STRAP, 2" WIDE @ 12" O.C. THIS LENGTH OF GUTTER AT RAKE
AutoCAD SHX Text
FASTEN METAL DRIP EDGE TO EXISTING PLYWOOD WITH #12 LOW PROFILE "CONCEALER" SCREWS AT 12" O.C.
AutoCAD SHX Text
24 GA. PRE-FINISHED GALVALUME METAL EAVE DRIP, SET IN SEALANT AND FASTEN TO BOTTOM EDGE OF ROOF PANELS WITH #12-14X3/4" HWH SELF DRILLING SCREWS WITH SEALING WASHERS, MIN. 3 PER PANEL
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
AT ROOF EDGE, SEAL OVER ANY VACANT FASTENER HOLES AND APPLY FLASHING GRADE ROOF COATING PRIOR TO FINISH COAT
AutoCAD SHX Text
EXISTING WALL FRAMING
AutoCAD SHX Text
EXISTING CONCRETE MASONRY BACK-UP WALL
AutoCAD SHX Text
SET FLASHING IN SEALANT AND FASTEN TO BOTTOM EDGE OF ROOF PANELS WITH #12-14X3/4" HWH SELF DRILLING SCREWS WITH SEALING WASHERS, 8" O.C.