Transcript

SD

SD

CP-30

CP-31

P.R.W.CT.

CAB. R, SL. 271-273

VISTA OAKS SECTION 4B

LOT 2

LOT 1, BLOCK B

TETCO STORE NO. 50

SUBDIVISION

HIGHLANDS NORTHWEST

SILVERADO PLAZA PHASE I

O.P.R.W.C.T.

DOC. #199957924

THE WHITESTONE BOULEVARD, LTD.

CALLED 25.00 ACRES

TRACT THREE

F&F CAPITAL, LLC

HIGHLANDS NORTHWEST SUBDIVISION

ARBOR PARK LOT 1 F&F CAPITAL, LLC

PARMER LANE VILLAGE SUBDIVISIONVILLAGE SUBDIVISION

PARMER LANE VILLAGE SUBD.

PARMER LANE

LOT 5, BLK A

RESUBD. OF

PARMER LANE VILLAGE SUBDIVISION

RESUBDIVISION OF LOT 5, BLOCK A

CAROLVILLE, LTD

WILL R. WILSON, JR., TRUSTEE

DIAMOND K PLUS, LTD

CITY OF CEDAR PARK

PATRICIA ANN CHERNOSKY, ET AL

MANOR INVESTMENTS, L.L.C.

SEALY TIMBER RIDGE &

CLEO BAY SUBDIVISION

CLEO BAY SUBDIVISION

TORO GRANDE SUBDIVISION

THE WHITESTONE BOULEVARD, LTD.

CLEO BAY IMPORTS, LTD

CEDAR PARK LAND, LP

THE WHITESTONE BOULEVARD, LTD.

CEDAR PARK LAND, LP

RAINBOW HEIGHTS

G. KATHERINE McCANN GALLOWAY

JAMES PATTON CARSSOW, ET AL.

WILLIAM E. STIPE, ET EUX

ALVIN LOYD RICE, ET EUX

PHASE TWO

SPANISH OAK TERRACE

JAMES PATTON CARSSOW, ET AL.

CITY OF ROUND ROCK

VISTA OAKS SECTION 7A & 7BVISTA OAKS SECTION 4B

THOMAS W. STEPHENS

JARED GLAZIER

DAVID J. SCHARA

ROBERT L. LAMBERT

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLYONLY

ONLY ONLY ONLY

ONLY

ONLYONLYONLY

ONLYONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

ONLY

U/E

ARV

42" WL

42"

WL (P

ER

GIS-

NO

T

MA

RK

ED)

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

42"

WL (P

ER

GIS-

NO

T

MA

RKE

D)

(PER GIS-

NOT

MAR

KED)

36"

WL

36" WL (PER GIS-NOT MARKED)

M

AR

KE

D)

(P

ER

GIS-

NO

T

36"

WL

24" WL (PER GIS)

M

AR

KE

D)

(P

ER

GIS-

NO

T

36"

WL

16"

WL (P

ER

GIS-

NO

T

MA

RK

ED)

16" WL (PER GIS-NOT MARKED)

FIBER OPTIC LINE NOT MARKED

FIBER OPTIC LINE NOT MARKED

FIBER OPTIC LINE NOT MARKED

FIBER OPTIC LINE NOT MARKED

FIBER OPTIC LINE NOT MARKED

FIBER OPTIC LINE NOT MARKED

11.3

0.1

0.5

1.4

0.8

0.1

0.8

Pop 14,842

0.8

1.1

GEORGETOWN

1.4

5.8

CITY

LIMIT

ROUND ROCK

CIT

Y

LIMIT

UP

0.4

2.2

1.6

1.3

1.3

Pop 30,923

1.5 ROUND

RO

CK

CIT

Y

RO

CK

CIT

Y

LIMIT

RO

CK

CIT

Y

LIM

IT

RO

UN

D

8.4

3.5

GE

OR

GE

TO

WN

RAIL

RO

AD

0.4

1.5

0.5

0.7

UP RR

CITY

LIMIT

1.2

GEORGETOWN

1.0

1.2

RAIL

WA

Y

NO

RT

HW

ES

TE

RN

4.2

AU

STIN

RAILWAY

NORTHW ESTERN

AU

STIN

6.1

1.8

Pop 5,161

0.1

10.7

ROUND ROCK

RO

UN

D

0.6

CEDAR PARK

2.8

4.3

PARK

CIT

Y

LIMIT

LIM

IT

LE

AN

DE

R

CIT

Y

LIM

IT

UP

UP

UP

B35

M

B35

L

B35

L

B35

L

B35

M

C

11.3

0.1

0.5

1.4

0.8

0.1

0.8

Pop 14,842

0.8

1.1

GEORGETOWN

1.4

5.8

CITY

LIMIT

ROUND ROCK

CIT

Y

LIMIT

UP

0.4

2.2

1.6

1.3

1.3

Pop 30,923

1.5 ROUND

RO

CK

CIT

Y

RO

CK

CIT

Y

LIMIT

RO

CK

CIT

Y

LIM

IT

RO

UN

D

8.4

3.5

GE

OR

GE

TO

WN

RAIL

RO

AD

0.4

1.5

0.5

0.7

UP RR

CITY

LIMIT

1.2

GEORGETOWN

1.0

1.2

RAIL

WA

Y

NO

RT

HW

ES

TE

RN

4.2

AU

STIN

RAILWAY

NORTHW ESTERN

AU

STIN

6.1

1.8

Pop 5,161

0.1

10.7

ROUND ROCK

RO

UN

D

0.6

CEDAR PARK

2.8

4.3

PARK

CIT

Y

LIMIT

LIM

IT

LE

AN

DE

R

CIT

Y

LIM

IT

UP

UP

UP

B35

M

B35

L

B35

L

B35

L

B35

M

C

PI STATION

DELTA

TANGENT

LENGTH

RADIUS

PC STATION

PT STATION

PI STATION

DELTA

TANGENT

LENGTH

RADIUS

PC STATION

PT STATION

PI STATION

DELTA

TANGENT

LENGTH

RADIUS

PC STATION

PT STATION

= 263+39.54

= 1,292.30

= 2,554.05

= 6,790.00

= 250+47.24

= 276+01.29

245+00

250+00

255+00 260+00

265+00

270+00

275+00

280+00

285+00

290+00

295+00

300+00

305+00

310+00

315+00

320+00

325+00

330+00

335+00

340+00PC 250

+64.37

PT 275

+84.56

PC 278

+85.89

PT 300

+72.93

PC 326

+97.98

PT 331

+53.02

PO

T 343

+00.40

= 329+25.15

= 227.58

= 455.04

= 8,500.00

= 326+97.57

= 331+52.61

= 289+92.48

= 1,106.99

= 2,187.03

= 5,730.00

= 278+85.49

= 300+72.52

G:\0977.002.000\07.00

CA

DD\

Sche

matic\01-

Sche

matic-

PE

R

Exhibits\1431_

Sche

matic_02.dgn

11:22:56

AM

12/16/2013

PROFILE LEGEND

NO. DATE REVISION APPROV. AT PGL

PROPOSED GRADE

AT PROPOSED PGL

NATURAL GROUND

PROFILE LEGEND

AT PGL

PROPOSED GRADE

AT PROPOSED PGL

NATURAL GROUND

RM 1431 WIDENING

NO. DATE REVISION APPROV.

RM 1431 WIDENING

0 100

1"= 10' (V)

SCALE 1"= 100' (H)

200 0 100

1"= 10' (V)

SCALE 1"= 100' (H)

200

Texas PE Firm Reg. # F-929

Phone: (512) 328-5771 Fax: (512) 328-5774

AUSTIN, TX 78746

BUILDING V, SUITE 220

901 SOUTH MOPAC EXPRESSWAY

Texas PE Firm Reg. # F-929

Phone: (512) 328-5771 Fax: (512) 328-5774

AUSTIN, TX 78746

BUILDING V, SUITE 220

901 SOUTH MOPAC EXPRESSWAY

240+00 245+00 250+00 255+00 260+00 265+00 270+00 275+00 280+00 285+00 290+00 295+00 300+00 305+00 310+00 315+00 320+00 325+00 330+00 335+00 340+00

LIMITS: 183A TO SAM BASS RD LIMITS: 183A TO SAM BASS RD810

820

830

840

850

860

870 870

860

850

840

830

820

810

840

830

820

810

800

790

780

260+00

840

830

820

810

800

790

780

880

870

860

850

840

830

820

295+00

880

870

860

850

840

830

820

Texas Department of Transportation Texas Department of Transportation

EL

EV

AT

PG

L

NG

AT

PG

L

EL

EV

AT

PG

L

NG

AT

PG

L

DESIGN SCHEMATIC

PRELIMINARY

DESIGN SCHEMATIC

PRELIMINARY

0977.002.000

12/16/2013COUNTY:

WILLIAMSON

CSJ:

1378-02-036

KLOTZ PROJECT #: SCALE:

1"=100'

DRAWN BY:

DWJ

SHEET #:

2OF 2

DATE:

0977.002.000

12/16/2013COUNTY:

WILLIAMSON

CSJ:

1378-02-036

KLOTZ PROJECT #: SCALE:

1"=100'

DRAWN BY:

DWJ

SHEET #:

2OF 2

DATE:

PLAN LEGENDPROPOSED PAVEMENT

EXISTING RIGHT OF WAY

PROPERTY LINE

100 YEAR FLOOD

EDWARDS AQUIFER BOUNDARY

CEDAR PARK CITY LIMITS

EASEMENT LINE

PLAN LEGENDPROPOSED PAVEMENT

EXISTING RIGHT OF WAY

PROPERTY LINE

100 YEAR FLOOD

EDWARDS AQUIFER BOUNDARY

CEDAR PARK CITY LIMITS

EASEMENT LINE

R R

DATE:

Under the authority of:

SUBMITTED FOR INTERIM REVIEW

BIDDING OR PERMIT PURPOSES

TO BE USED FOR CONSTRUCTION,

100% PRELIMINARY

DECEMBER 2013, IT IS NOT

BRADLEY R BROWN, P.E. No. 79239

DATE:

Under the authority of:

SUBMITTED FOR INTERIM REVIEW

BIDDING OR PERMIT PURPOSES

TO BE USED FOR CONSTRUCTION,

100% PRELIMINARY

DECEMBER 2013, IT IS NOT

BRADLEY R BROWN, P.E. No. 79239

[

DEPTH UNKNOWN

[ STA 248+17.18

16" WATER LINE

EXISTING

DEPTH UNKNOWN

[ STA 248+69.80

FIBER OPTIC LINE

EXISTING

DEPTH UNKNOWN

[ STA 251+63.80

GAS LINE

EXISTING

DEPTH UNKNOWN

[ STA 251+52.25

GAS LINE

EXISTING

DEPTH UNKNOWN

[ STA 256+71.24

8" WATER LINE

EXISTING

RONALD REAGAN BLVD.

PARMER LANESTA = 242+00.00

EL = 864.08'

(-)1.4564 %

(-)1.4564 % (-)4.2015 %

EL.

= 850.10 '

VP

C 251

+60.00

EL.

= 837.37 '

VP

T 256

+10.00

K = 164

ex = -1.54

L = 450.00'

EL = 846.82'

STA = 253+85.00

(-)1.5604 %859.7

858.2

865.7

864.1

862.7

861.3

856.9

855.4

854.0

852.5

850.7

848.6

846.0

843.0

839.7

836.3

832.7

829.1

825.3

865.64

864.08

862.62

861.17

859.71

858.25

856.80

855.34

853.88

852.43

850.97

849.47

847.46

844.85

841.62

837.79

833.59

829.39

825.18

820.98

[

C TORO GRANDE DRIVEL

] EL 777.92

[ STA 266+37.27

42" WASTEWATER LINE

EXISTING

DEPTH UNKNOWN

[ STA 271+37.22

FIBER OPTIC LINE

EXISTING

DEPTH UNKNOWN

[ STA 277+54.98

12" WATER LINE

EXISTING

CR 272

[BRUSHY CREEK

] EL 785.39

[ STA 264+14.56

PROPOSED 72" CMP EXTENSION

EXISTING 72" CMP

STA = 267+44.50

EL = 802.92'

K = 117

ex = 2.57'

L = 490.00'

EL = 802.92'

STA = 264+30.00

K = 205

ex = 0.24'

L = 200.00'

EL = 805.00'

STA = 273+40.00

EL 795.46

25YR WSEEL 799.11

100YR WSE

(-)4.2015 %(+)0.0000 % (+)0.0000 %

(+)0.3500 %(+)1.3259

%

EL.

= 813.21 '

VP

C 261

+85.00

EL.

= 802.92 '

VP

T 266

+75.00

EL.

= 804.65 '

VP

C 272

+40.00

EL.

= 806.33 '

VP

T 274

+40.00

] EL 819.45

[ STA 289+05.85

PROPOSED 30" RCP

PROPOSED 2-50"x33" CMP EXTENSION

EXISTING 2-50"x33" CMP

821.3

817.2

813.1

809.2

806.2

804.1

784.2

802.8

802.8

802.8

802.8

802.9

803.5

804.5

805.8

807.2

808.5

809.7

811.1

812.5

813.6

814.9

816.2

817.3

818.5

819.8

821.1

822.3

823.6

824.9

826.2

827.5

828.8

830.1

831.3

820.98

816.78

812.59

808.94

806.16

804.23

803.16

802.92

803.11

803.46

803.81

804.16

804.51

804.95

805.83

807.12

808.45

809.77

811.10

812.43

813.75

815.08

816.40

817.73

819.05

820.38

821.71

823.03

824.36

825.68

827.01

828.34

829.66

830.99

832.31

833.64

LC RALEY ROAD

[

DEPTH UNKNOWN

[ STA 299+28.58

12" WATER LINE

EXISTING

FUTURE COLLECTOR[

CR 175

SAM BASS ROAD

K = 300

ex = -2.04'

L = 700.00'

EL = 872.49'

STA = 325+50.00

K = 179

ex = -1.74'

L = 500.00'

EL = 869.52'

STA = 305+50.00

K = 200

ex = -0.56'

L = 300.00'

EL = 877.17'

STA = 312+15.00

] EL 833.02

[ STA 299+22.18

PROPOSED 54"x42" ARCHED CMP EXTENSION

EXISTING 54"x42" ARCHED CMP

K = 153

ex = 1.31'

L = 400.00'

EL = 836.42'

STA = 297+10.00

(+)1.3259

% (+)3.9

400

%

(+)3.9

400

%(+)1.

1500 %

(+)1.1500

% (-)0.3500 %

(-)0.3500 % (-)2.6800 %

(-)2.6800 %

EL.

= 833.77 '

VP

C 295

+10.00

EL.

= 844.30 '

VP

T 299

+10.00

EL.

= 859.67 '

VP

C 303

+00.00

EL.

= 872.39 '

VP

T 308

+00.00

EL.

= 875.44 '

VP

C 310

+65.00

EL.

= 876.64 '

VP

T 313

+65.00

EL.

= 873.72 '

VP

C 322

+00.00

EL.

= 863.11 '

VP

T 329

+00.00

EL.

= 859.09 '

VP

C 330

+50.00

EL.

= 854.10 '

VP

T 333

+80.00

(-)0.3500 %

K = 142

ex = 0.96'

L = 330.00'

EL = 854.67'

STA = 332+15.00

] EL 842.80

[ STA 332+40.25

PROPOSED 7x6 BC

PROPOSED 2-10x8 BC EXTENSION

EXISTING 2-10x8 BC

852.8

852.3

851.9

851.7

851.6

851.4

851.3

832.6

834.4

836.7

839.7

843.3

847.3

851.4

855.4

859.4

862.9

865.9

868.3

870.2

871.7

873.0

874.3

875.5

876.3

876.6

876.6

876.4

876.1

875.9

875.9

875.8

875.6

875.5

875.1

874.5

873.4

871.7

869.6

867.3

864.9

862.5

860.1

857.6

855.2

853.6

853.1

833.64

835.23

837.47

840.37

843.91

847.85

851.79

855.73

859.67

863.33

866.43

868.98

870.97

872.39

873.54

874.69

875.81

876.54

876.76

876.52

876.17

875.82

875.47

875.12

874.77

874.42

874.07

873.72

873.20

872.35

871.17

869.66

867.81

865.63

863.11

860.43

857.84

855.87

854.60

854.03

853.68

853.33

852.98

852.63

852.28

851.93

851.58

2 %

[ RM 1431

PGL

10:1

3:1 (MAX)

4:1 (TYP)

2 %

[ RM 1431

PGL

10:1

3:1 (MAX)

4:1 (TYP)

[ RM 1431

SHLDR

12'12'12'12'12'

14' 12' 12'

2' 2'

14'12'12'

14'12'12'

3:1 (MAX)

4:1 (TYP)

EXI

STI

NG

RO

W

EXI

STI

NG

RO

W

EXI

STI

NG

RO

W

EXI

STI

NG

RO

WE

XI

STI

NG

RO

W

EXI

STI

NG

RO

W

WITH TURN LANES

PROPOSED RM 1431

PROPOSED RM 1431

EXISTING RM 1431

Option 1

[ RM 1431

2.7 %2.7 %

EXI

STI

NG

RO

W

EXI

STI

NG

RO

W

14'12'12'

200 EXIST ROW'

35' WIDENING

29' 65'

53' 53'

66'67' 67'

& GUTTER

TY II CURB

200' EXIST ROW'

200' EXIST ROW'

200' EXIST ROW'

WALKSIDE

5'

WALKSIDE

2'

2'2'

2' 2'

2'2'

RAISED MEDIAN

5' - 29'

5'-17'

43.5'

56.5'56.5'- 68.5'

BRUSHY CREEK BRIDGE

PROPOSED RM 1431

STA. 265+47.11 TO STA. 266+87.20

STA. 141+56.00 TO STA. 341+91.40

14' 12' 12'

113'- 125'

6'

2 %

[ RM 1431

PGL

2 %10:1

3:1 (MAX)

4:1 (TYP)

3:1 (MAX)

4:1 (TYP)

EXI

STI

NG

RO

W

EXI

STI

NG

RO

W

WITH TURN LANES

PROPOSED RM 1431& GUTTER

TY II CURB

212' EXIST ROW'

2' 2'

2'2'

5'-29'

31.5' - 43.5'113'- 137'

3'

SHLDR

3'

PGL

STA. 321+40.43 TO STA. 329+24.53

STA. 304+00.40 TO STA. 306+50.40

STA. 286+00.00 TO STA. 293+58.42

STA. 269.61.49 TO STA. 278+16.33

6'

14' 12' 12'

56.5' 56.5'-68.5'

MIN.

MIN.

5'

MIN.

5'

2'

43.5 - 55.5'

5'

TY II C&GTY II C&G

BREAK

X-SLOPE

2.5 %

BREAK

X-SLOPE

2.5 %

BREAK

X-SLOPE TY II C&G

TY II C&G

2.5 %

BREAK

X-SLOPE

2.5 %2 %

TY II C&G

TY II C&G

2.5 %

BREAK

X-SLOPE

2.5 %

BREAK

X-SLOPE

2 %

4.5'

106'

200 EXIST ROW'

STA. 329+24.55 TO STA. 336+37.38

STA. 314+39.75 TO STA. 320+90.40

STA. 293+58.42 TO STA. 302+00.40

STA. 278+16.33 TO STA. 286+00.00

STA. 336+75.00 TO STA. 341+91.00

STA. 205+85.10 TO STA. 211+90.00

STA. 198+10.00 TO STA. 204+24.69

STA. 179+00.00 TO STA. 182+43.63

STA. 226+96.55 TO STA. 236+00.00*

STA. 211+90.00 TO STA. 219+70.00

STA. 182+43.63 TO STA. 190+25.00

STA. 165+52.00 TO STA. 174+00.00

STA. 150+14.24 TO STA. 156+94.00

STA. 306+80.00 TO STA. 321+40.00

STA. 266+87.20 TO STA. 270+50.17

STA. 263+50.00 TO STA. 265+47.11*

STA. 219+70.00 TO STA. 226+96.55

STA. 190+25.00 TO STA. 198+10.00

STA. 174+00.00 TO STA. 179+00.00

STA. 156+94.00 TO STA. 165+52.00

STA. 141+56.00 TO STA. 150+14.24

4.5'

12' 0'-12' 12' 12' 14' 0-12'

12'0'-12'12'12'14'0-12'

43.5 - 55.5'

44.5' - 56.5'44.5' - 56.5'

89' - 113'

1.5%

5' SDWK

31.5' - 43.5'

1.5%

5' SDWK

3:1 (MAX)

4:1 (TYP)

43.5'

1.5%

5' SDWK*

*

*

EXISTING PGL

PROPOSED PGL

PROPOSED PGL

EXISTING PGL

PROPOSED PGL

EXISTING PGL

100 YR FLOODPLAIN

200'

R.O.W. 200'

R.O.W.

R.O.W.280.5'

CI

TY

OF

CE

DA

R

PA

RK

CI

TY

LI

MI

TS

RE

CH

AR

GE

ZO

NE

ED

WA

RD

S

AQ

UI

FE

R

CO

NT

RI

BU

TI

NG

ZO

NE

ED

WA

RD

S

AQ

UI

FE

R

RECHARGE ZONE

EDWARDS AQUIFER

CONTRIBUTING ZONE

EDWARDS AQUIFER

PA

RK

CI

TY

LI

MI

TS

CI

TY

OF

CE

DA

R

[ RM 1431 STA 250+58.94ELEV. 819.47

TBM-2

ELEV. 806.98

CP-31

ELEV. 811.80

TBM-3

ELEV. 859.36

TBM-4

ELEV. 875.43

TBM-5

ELEV. 876.18

TBM-6

ELEV. 856.44

TBM-7

CO

NT

RI

BU

TI

NG

ZO

NE

ED

WA

RDS

AQ

UIF

ER

RE

CH

AR

GE

ZO

NE

ED

WA

RDS

AQ

UIF

ER

STA. 341+91.40

CSJ# 1378-02-036

END PROJECTELEV. 847.72

TBM-1

ELEV. 806.98

CP-30

200'

R.O.W.

CONC. MULTI. BOX CULV.

EXISTING 2 - 10'X 8'

[ STA 332+39.85

CMP CULVERT

EXISTING 2-50" X33"

[ STA 289+05.41

20' WATER/WW EASEMENT

5' P.U.E.

5' P.U.E.

20' WATER/WW EASEMENT

25' BL. AND LANDSCAPE EASEMENT

10' P.U.E.

20' WATER/WW EASEMENT

40' FILL EASEMENT

7' P.U.E.

20' P.U.E.

CMP CULVERT

EXISTING 1-72"

STA 264+14.36

ARCHED CMP CULVERT

EXISTING 1-54"X 42"

[ STA 299+21.78

20' WATER/WW EASEMENT

25' LANDSCAPE EASEMENT

10' P.U.E.25' B.L. LANDSCAPE EASEMENT

20' P.U.E.

25' BL. & LANDSCAPE EASEMENT

20' WATER/WW EASEMENT 10' P.U.E.

75' WIDE ACCESS EASEMENT

20' WATER/WW EASEMENT

10' P.U.E.

20' WATER/WW EASEMENT

20' WATER/WW EASEMENT

20' WATER LINE EASEMENT10' EASEMENT

10' EASEMENT

7' P.U.E.

7' P.U.E.20' WATER/WW EASEMENT

150' RADIUS SANITARY EASEMENT

15'

P.U.

E.

25' LANDSCAPE EASEMENT

15' P.U.E.

25' PEDESTRIAN ACCESS EASEMENT

10' P.U.E.

10' P.U.E.

20' WATER LINE EASEMENT

25' LANDSCAPE EASEMENT

25' LANDSCAPE EASEMENT

20' P.U.E.25' BL. LANDSCAPE EASEMENT

20' WATER/WW EASEMENT

10' P.U.E.

15' LANDSCAPE

20' LANDSCAPING, UTILITIES, AND ST. SEW. EASEMENT

30' WW EASEMENT

BEGIN BRIDGE

STA 265+47.11

EASEMENT

20' WATER/WW

ELEV. 803.64

STA 265+45.42

BEGIN BRIDGE ELEV. 802.92

END BRIDGE

STA 266+88.11

END BRIDGE

STA 266+87.20

SIDEWALK

PROPOSED

250+64.40 TO STA. 278+22.40

NORTH SIDE OF PROJECT FROM STA.

SIDEWALK TO BE CONSTRUCTED ON

FLOW INTERSECTION.

INCLUDED IN LIMITS OF CONTINUOUS

STA. 236+00.00 TO STA. 263+50.00 *NOTE:

ELEV. 851.26

STA. 341+91.40

CSJ# 1378-02-036

END PROJECT

MA

TC

HLI

NE -

ST

A. 241

+00.00

LOCATION MAP - N.T.S.LOCATION MAP - N.T.S.

FM 1431

Cedar Park

Georgetown

Round Rock

35Ronald R

eagan Blvd.

183

A

FM 2243

SH 29

Project LocationUS 1

83

Cedar Park

Georgetown

Round Rock

35Ronald R

eagan Blvd.

183A

FM 2243

SH 29

Project LocationUS 1

83

Sam Bass Rd

PA

RM

ER

LA

NE

RM 1431

CR 272

CR 272

TO

RO

GR

AN

DE

DRI

VE

RM 1431 RM 1431

RM 1431

CR 175

SA

M

BA

SS

RO

AD

BR

US

HY CREE

K

RA

LE

Y

RD

PRELIMINARY SUBJECT TO CHANGE

Sam Bass Rd

EXISTING SIGNAL

EXISTING SIGNAL

EXISTING SIGNAL

FU

TU

RE

CO

LL

EC

TO

R

.D

VL

B

NA

GA

ER

DL

AN

OR

THE ELEVATIONS ARE BASED ON THE NAVD-88.

USING A COMBINED SCALE FACTOR OF 1.00011.

CENTRAL ZONE (4203) AND ADJUSTED TO SURFACE

COORDINATE SYSTEM, NAD-83(1993)HARN, TEXAS

COORDINATES BASED ON THE TEXAS STATE PLANE

RECHARGE ZONE

EDWARDS AQUIFER CONTRIBUTING AND

RAILROADS:NONE

EXCEPTIONS:NONE

EQUATIONS:NONE

FUNCTION CLASS:URBAN PRINCIPAL ARTERIAL

60 M.P.H. (FROM PARMER LANE TO CR 175)

45 M.P.H. (FROM 183A TO PARMER LANE)

DESIGN SPEED:

71,200 VPD (2031)

ADT:38,600 VPD (2011)

ASPHALTIC CONCRETE PAVEMENT AND BRIDGE.

GRADING, DRAINAGE STRUCTURES, BASE COURSE,

PROJECT DESCRIPTION: CONSTRUCTION OF EARTHWORK,

(SAM BASS ROAD)

PROJECT LIMITS: FROM 183A TOLL ROAD TO CR 175

PROJECT LENGTH: 20,035.00 FT. (3.795 MI.)

BRIDGE LENGTH: 303.10 FT. (0.057 MI.)

ROADWAY LENGTH: 19,731.90 FT. (3.737 MI.)

THE ELEVATIONS ARE BASED ON THE NAVD-88.

USING A COMBINED SCALE FACTOR OF 1.00011.

CENTRAL ZONE (4203) AND ADJUSTED TO SURFACE

COORDINATE SYSTEM, NAD-83(1993)HARN, TEXAS

COORDINATES BASED ON THE TEXAS STATE PLANE

RECHARGE ZONE

EDWARDS AQUIFER CONTRIBUTING AND

RAILROADS:NONE

EXCEPTIONS:NONE

EQUATIONS:NONE

FUNCTION CLASS:URBAN PRINCIPAL ARTERIAL

60 M.P.H. (FROM PARMER LANE TO CR 175)

45 M.P.H. (FROM 183A TO PARMER LANE)

DESIGN SPEED:

71,200 VPD (2031)

ADT:38,600 VPD (2011)

ASPHALTIC CONCRETE PAVEMENT AND BRIDGE.

GRADING, DRAINAGE STRUCTURES, BASE COURSE,

PROJECT DESCRIPTION: CONSTRUCTION OF EARTHWORK,

(SAM BASS ROAD)

PROJECT LIMITS: FROM 183A TOLL ROAD TO CR 175

PROJECT LENGTH: 20,035.00 FT. (3.795 MI.)

BRIDGE LENGTH: 303.10 FT. (0.057 MI.)

ROADWAY LENGTH: 19,731.90 FT. (3.737 MI.)

303+73.00 - END

300+19.00 - 303+73.00

279+40.00 - 300+19.00

275+50.00 - 279+40.00

250+97.00 - 275+50.00

247+63.00 - 250+97.00

BEGIN - 247+63.00

STATION

-2.00%

-2.36%

2.36%

-2.00%

SLOPE DIRECTION

TRANSITION

TRANSITION

TRANSITION

-2.00%

2.36%

-2.36%

-2.00%

SLOPE DIRECTION

TRANSITION

TRANSITION

TRANSITION

X-SLOPE DATA EB ROADWAY WB ROADWAY

CR 178

Parm

er

Ln

Blv

dReagan

Ronald

113(191)

1121(1435)

273(276)

308(5

67)

228(7

21)

434(6

55)

125(9

7)

718(3

08)

249(1

65)

112(197)

1224(1392)

715(717)

AM(PM)XXX(XXX) =

FM1431

CR

175

58(213)

1388(1639)

208(238)

28(1

14)

210(4

04)

176(1

06)

103(149)

1656(1726)

AM(PM)XXX(XXX) =

FM1431

48(4

4)

97(9

2)

20(31)

30(4

0)

Bass R

dSa

m

DR

WY

Dr

Gra

nde

Toro

26(109)

1650(2056)

2(2)

2(2)

2(2)

16(1

04)

7(34)

2033(2200)

AM(PM)XXX(XXX) =

FM1431

2(2)

2(3

2)

2(2)

2(2)

Recommended