PERMANENT EDGE PROTECTION SYSTEM
ELITE MODEL Modular Fall Protection System for securing
flat and inclined surfaces, according to EN 14122 - 3
OPERATING AND MAINTENANCE MANUAL
FALL PROTECTION SYSTEM
- 2 -
Index
1. Introduction 3
2. Norms and certifications 3
3. General information 4
4. Loads moved from the post to the anchorage point 4
5. Description of the item and its components 5
6. Expected usage and limitations 5
7. General use conditions and use examples 6
8. Handling & Storage 7
9. Assembling and disassembly the components 8
10. Maintenance 10
11. Dimensions ____________________________________ 11
FALL PROTECTION SYSTEM
- 3 -
1. Introduction
The present manual has been realized following the new regulations of the standard EN 13374 : 2013, with the aim of proving
to the user an appropriate awareness of the equipment and living the information for:
the correct sensitization of the users on the security problems;
the expected usage of the equipment;
the safe conditions for the handling, the installation, the usage and the maintenance;
Demolition and disposal, according to the current regulations to protect the health of the workers and the
environment.
MH recommends to read it carefully before the usage of the product, paying particular attention to highlighted
messages.
The respect of the standards and recommendations on the manual allows you to get a safe usage and an appropriate
maintenance work.
The manual is part of the provided equipment: it’s essential to preserve it and to use it all along the equipment life.
2. Norms and Certifications
Norm UNI EN 14122-3 : 2010
Safety of machinery. Permanent means of access to machinery. Stairways, stepladders and guard-rails
Italian Legislative Decree n° 81/ 2008
Healthcare and safe preservation into the work places.
The guard-rail has been tested according to the standard EN 14122-3 by engineering calculation by a qualified engineer
and member of the Order of Engineers” (see Deliverable calculation No. At054-PR).
FALL PROTECTION SYSTEM
- 4 -
3. General information
The producer guarantees its item for the defects of production or for material faults of this law period/decree.
The producer doesn’t account for the eventually harms or damages to people or objects due to the improper usage of the equipment or
due to the wrong installation or due to all the actions not included in this manual.
The guarantee lapses in the following cases:
the product has been damaged or tampered;
the product has been improperly utilized;
the product has benn used without respecting the limitations of this manual or it has excessive mechanical pressing;
the wrong or missed maintenance of the product;
the product has been subjected to damages during the transport, the installation or the usage;
the product has got false components.
During the receipt of the goods, the customer must check it to verify if there are some mistakes, damages due to the transport or faults of
the supply.
The possible faults, damages or incompleteness must be recommended to Metal House S.r.l. through a written comunication, counter-
signed by the vector.
4. Loads moved from the post to the anchorage point at the highest limit
Fo : Horizontal Strenght Fv : Vertical Strenght M : Momentum
Load conditions
According to UNI EN
14122 - 3
Last Limit State
Accidental Limit State
Fo (daN)
Fv (daN)
M (daNm)
+/- 80
+ 25 +/- 100
/
+ 160
/
M
Fo
Fv
fig. 1
FALL PROTECTION SYSTEM
- 5 -
5. Description of the item and its compontens
The permanent edge protection system “Elite” is made by tubular uprights 60x30x2 (3) and by two horizontal elements: the handrail
and the intermediate railing (1-2). The railings are connected to each other thanks to the conification at the end. (6) . The upright (3) has
a plate welded on its base (4) used for fixing the system to the surface (5).
6. Expected use and limitations
This edge protection system is made and certified as a protection against falling from above during the phase of access to machinery.
This parapet can carry a person that is resting on it or that is falling against it..
The user must control the efficiency of the anchorage (in reference to the loads recommended in this manual) according to the
actual conditions of the surfaces on which the system has to be installed.
The impropriate installation of the parapet could cause fallings or injuries!
FALL PROTECTION SYSTEM
- 6 -
7. General terms of use and usage examples
The use of this fall protection system requires certain employment conditions:
If a curb or a wall at least 150 mm tall are absent, a toe-board must be installed;
Minimum height of the toe-board : 150 mm;
The upper edge of the toe-board must be at least 150 mm over the working surface;
Minimum height of the parapet compared to the decking: 1100 mm;
The maximum opening between two segments of the guard-rail (in the case that it’s discontinued) must be between 75 mm e
125 mm. If the space is wider than 125 mm a gate must be installed;
The space between the railings (handrail, intermediate railing and toe-board) must be equal or smaller than 500 mm;
The space between the lower edge of the toe-board and the walking surface must be smaller than 10 mm. MAXIMUM DISTANCE between the posts is 1500mm
Usage examples (fig. 2 - 3 - 4)
Railing fixed to the external wall, without a curb, with the toe-board installed
Railing fixed to the curb, from the external side
Railing fixed to the curb from the inner side
fig. 2
fig. 3
fig. 4
FALL PROTECTION SYSTEM
- 7 -
8. Handling & Storage
Whoever interacts with the equipment in any way must strictly comply with the recommendations described below:
The operations of packaging, handling, transport and unpacking must be performed only by qualified personnel
with perfect knowledge of the equipment, referring to the accident prevention regulations in force;
Handling equipment for lifting and carrying must be intact and able to execute safely the operations required, taking
into account the size, weight, protruding/delicate parts and the center of gravity of the equipment;
Avoid inappropriate handling and use; especially avoid performing maneuvers if outside of your own field of exper-
tise and responsibilities;
Always wear work gloves and safety shoes;
Never put your hands or any part of the body under raised components/suspended loads;
Do not wear rings, watches, bracelets or loose and dangling clothing during the assembly and disassembly of the
equipment.
Handling
The post is normally shipped in multi-packs and secured on pallets. The package handling must be done with a lift with forks that
can move at least a weight as heavy as the one of the packaging, as indicated in the delivery receipt. The unpacking operations are
limited to the elimination of plastic protection and fastenings used to secure the items on pallets.
The plastic material used for packaging is a pollutant and it should not be burned (causes toxic fumes), neither dispersed in
the environment but disposed of according to law.
Collect every item of waste in special containers, according to the directions for the collection of waste.
Storage
The item must possibly be stored in such a position as not to be subjected to forces that may damage its components avoiding con-
tact with sharp edges. Must be stored in a dry and well ventilated space and in any case not in presence of water or other contami-
nants or corrosive.
FALL PROTECTION SYSTEM
- 8 -
9. Assembly and disassembly of the components
It is up to the user to verify that the structure to which the item will be fixed is actually capable of supporting the loads
transferred (see point 4, page 4);
During the assembly and disassembly phases, in addition to the risks associated with manual handling of loads or the use
of equipment (drill fastening tools manual), there is a danger of falling into the void. Therefore it is necessary the use of
other systems of prevention and protection, such as ropes fall, working platforms or other suitable and certified system;
For the assembly and disassembly of the system use certified working platforms or equivalent structures;
Before every use, the user must verify the absence of corrosion, damages to the materials and welds, as well as the absence
of deformations or dents of each component;
Eliminate any water and thoroughly clean all parts. If there is the presence of corrosion or deformation, the part must be
replaced and tested by a competent person, whose written opinion -combined with traceability- will be binding for the
purpose of reuse;
In any case, the post must be inspected every year by competent personnel;
The anchorage points must be verified by competent personnel at least every 6 months.
If fall arrest has happened to the post, it should be immediately removed from service and tested by a competent person.
Assembly (fig. 5 - 6 - 7 - 8 - 9)
Use a working platform and/or the appropriate personal protective equipment (PPE);
Fix to the wall the first upright (fig. 5, page 8);
Position the second upright with a maximum interval of 150 cm (fig. 6, page 9);
Insert the intermediate railing and the handrail through the uprights (fig. 7 page 9); then, tighten the screws on the uproghts
in order to lock the horizontal railings (fig. 8 page 9);
If the toe-board has to be installed, (see point 7 page 6), proceed with its installation: position it and fasten it to the uprights
with the fixing system supplied by Metal House Srl.
Anchor the first upright to the wall, using 4 adequate bolts
according to supporting the loads transferred (usual type
M10). Make sure that the upright is perfectly perpendicular to
the walking floor (fig.5)
FALL PROTECTION SYSTEM
Fig.5
- 9 -
Proceed as above for the second upright. Keep the
posts at a maximum interval of 1500 mm.
Insert the horizontal elements Ø 32 mm through the ap-
propriate holes in the uprights.
Fasten the appropriate screws supplied (screws TE M8X16), in
order to lock the guardrails to the uprights.
FALL PROTECTION SYSTEM
Fig.8
Fig.7
Fig.6
Type supplied self-tapping drilling screws 4.8x10mm
Make sure that the tubes that make up the handrail
and the intermediate barrier are fully engaged with
each other to the limit!
When are adhered to one another it is necessary to
connect the 2 tubes by means of self-tapping screws
4.8x10mm type (supplied by Metal House) by ex-
ploiting the hole of 5mm diameter on the hose fe-
male.
Fig.9
- 10 -
Disassembly
For disassembly, using a certified and safe working platform, loosen the screws on the uprights and remove the horizontal
elements. Than, remove the anchors and the uprights..
The sequence of operations to safely disassembly the system must be such as to keep it, as much as possible, at work:
therefore, remove the horizontal elements first (eg. boards).
N.B.: While disassembling the protections it’s necessary to hold the components tight, in order to prevent dangers
arising from the fall.
10. Maintenance
The maintenance and testing must be performed by authorized personnel with considerable knowledge of the
systems for temporary railing and safety practices.
It is recommended to periodically check the state of conservation of the temporary guard rail posts, greasing the
moving parts such as screws and pins.
A good preservation of the surface of the post for temporary railing eliminates possible hazards from weakening
(eg. due to corrosion).
The post must be inspected every year by competent personnel.
Extra-ordinary maintenance actions must be registered in reference to the kind and the outcome.
If fall arrest has happened to the post, it should be immediately removed from service and tested by a competent
person.
Inspection activities must be registered on card, which must be available to the user.
FALL PROTECTION SYSTEM
- 11 -
11. Dimensions
1. Tubular Ø 32x2 S 235 JR G2
2. Tubular 60x30x2 S 235 JR G2
3. Tape 147x3.5 bent S 235 JR G2
Max 1500 mm
FALL PROTECTION SYSTEM
> 1
10
0 m
m
Floor level
PERMANENT EDGE PROTECTION SYSTEMS
Metal House Srl
Via del Lavoro 15 36070 Brogliano (VI)
Tel 0445-1752895 Fax 0445-1752886
E-mail : [email protected] www.metalhouse.it
PERMANENT EDGE PROTECTION SYSTEM
ELITE MODEL
Data recording
The inspection must be recorded on the card.
Date Element State Operation Report Notes