IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 4
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.
3b
id+ high ceiling 6"& 8" round
FL6H | FL8H
x4
key
power off power on
level attention
65/8” min63/4” max
1
non-emergency
see additional instructions
LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING. ALL LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE.
emergency - remote test switch
downlight wall wash
811/16” min87/8” max
REMOVE ZIP TIE PRIOR TO INSTALLATION
5 x4
WA
LL
wall wash orientation
trim
fl6h fl8h
x2
6" 8"
secure to structure aBove with 1/4 x 20 threaded rod or tiewire (By others)
GRID - 1/2" CONDUIT & CLIP (BY OTHERS)
X22
X23a
LOOSEN SCREWS TO ADJUST HEIGHT OF HOUSING
4
IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 4
Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.
DRYWALL
5 X4
make electrical connections
8 EMERGENCY
DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND A.C. POWER IS SUPPLIED
CB
release indicator
from Bracket prior to
installation
(JBOX SIDE)
1.76" Ø .166" (EDGE OF FLANGE TO CENTER OF HOLE)
8"
(JBOX SIDE)
2.80" Ø .166"
(EDGE OF FLANGE TO CENTER OF HOLE)
6"
6
secure to structure aBove with 1/4 x 20 threaded rod or tiewire (By others)
2 3 4a X2X2X2
1/2" conduit By others
4b
LOOSEN SCREWS TO ADJUST HEIGHT OF HOUSING
7
1/4" max above ceiling
A
SEE BATTERY MANUFACTURER INSTRUCTIONS
emergency maximum mounting height: 35.00'
IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 4
Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.
OPTIC ASSEMBLY
E
adjust indicator until canopy is flush with ceiling
21
REMOVE TRIM
see trim removal ON PAGE 5 OF INSTRUCTION SHEET
loosen thumB screw
3
4 5
REVERSE STEPS
FOR INSTALLATION
OF OPTIC
DRIVER SERVICE
loosen wingnut
21REMOVE TRIM
see trim removal ON PAGE 4 OF INSTRUCTION SHEET
STEPS 2-4 APPLY TOALL WALL WASH
& 6" DOWNLIGHT ONLY. 8" DOWNLIGHT SKIP TO STEP 5
3
RAISE HEAT SINK FOR CLEARANCE
11D
Contractor is responsible for adequately reinforcing walls and/or ceilings to support fixture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited.
IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 4
5
DOWNLIGHT TRIM
21 3
center trim on led module
1 3
WALL WASH
2
WA
LL
WA
LL
tighten wingnut
4
DOWNLIGHT WALL WASH
1 1
TRIM REMOVAL DO NOT PULL ON TRIM FLANGE