IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 4 Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. 3b id + high ceiling 6"& 8" round FL6H | FL8H x4 KEY POWER OFF POWER ON LEVEL ATTENTION 6 5 /8” min 6 3 /4” max 1 NON-EMERGENCY SEE ADDITIONAL INSTRUCTIONS LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING. ALL LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE. EMERGENCY - REMOTE TEST SWITCH DOWNLIGHT WALL WASH 8 11 /16” min 8 7 /8” max REMOVE ZIP TIE PRIOR TO INSTALLATION 5 x4 WALL WALL WASH ORIENTATION TRIM FL6H FL8H x2 6" 8" SECURE TO STRUCTURE ABOVE WITH 1/4 X 20 THREADED ROD OR TIEWIRE (BY OTHERS) GRID - 1 / 2" CONDUIT & CLIP (BY OTHERS) X2 2 X2 3a LOOSEN SCREWS TO ADJUST HEIGHT OF HOUSING 4

id+ high ceiling 6& 8 round_FL6H_FL8H... · C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | 1 of 4 Luminaires must be installed by a qualified electrician (check

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: id+ high ceiling 6& 8 round_FL6H_FL8H... · C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | 1 of 4 Luminaires must be installed by a qualified electrician (check

IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 4

Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

3b

id+ high ceiling 6"& 8" round

FL6H | FL8H

x4

key

power off power on

level attention

65/8” min63/4” max

1

non-emergency

see additional instructions

LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING. ALL LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE.

emergency - remote test switch

downlight wall wash

811/16” min87/8” max

REMOVE ZIP TIE PRIOR TO INSTALLATION

5 x4

WA

LL

wall wash orientation

trim

fl6h fl8h

x2

6" 8"

secure to structure aBove with 1/4 x 20 threaded rod or tiewire (By others)

GRID - 1/2" CONDUIT & CLIP (BY OTHERS)

X22

X23a

LOOSEN SCREWS TO ADJUST HEIGHT OF HOUSING

4

Page 2: id+ high ceiling 6& 8 round_FL6H_FL8H... · C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | 1 of 4 Luminaires must be installed by a qualified electrician (check

IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 4

Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

DRYWALL

5 X4

make electrical connections

8 EMERGENCY

DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND A.C. POWER IS SUPPLIED

CB

release indicator

from Bracket prior to

installation

(JBOX SIDE)

1.76" Ø .166" (EDGE OF FLANGE TO CENTER OF HOLE)

8"

(JBOX SIDE)

2.80" Ø .166"

(EDGE OF FLANGE TO CENTER OF HOLE)

6"

6

secure to structure aBove with 1/4 x 20 threaded rod or tiewire (By others)

2 3 4a X2X2X2

1/2" conduit By others

4b

LOOSEN SCREWS TO ADJUST HEIGHT OF HOUSING

7

1/4" max above ceiling

A

SEE BATTERY MANUFACTURER INSTRUCTIONS

emergency maximum mounting height: 35.00'

Page 3: id+ high ceiling 6& 8 round_FL6H_FL8H... · C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | 1 of 4 Luminaires must be installed by a qualified electrician (check

IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 4

Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.

OPTIC ASSEMBLY

E

adjust indicator until canopy is flush with ceiling

21

REMOVE TRIM

see trim removal ON PAGE 5 OF INSTRUCTION SHEET

loosen thumB screw

3

4 5

REVERSE STEPS

FOR INSTALLATION

OF OPTIC

DRIVER SERVICE

loosen wingnut

21REMOVE TRIM

see trim removal ON PAGE 4 OF INSTRUCTION SHEET

STEPS 2-4 APPLY TOALL WALL WASH

& 6" DOWNLIGHT ONLY. 8" DOWNLIGHT SKIP TO STEP 5

3

RAISE HEAT SINK FOR CLEARANCE

11D

Page 4: id+ high ceiling 6& 8 round_FL6H_FL8H... · C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | 1 of 4 Luminaires must be installed by a qualified electrician (check

Contractor is responsible for adequately reinforcing walls and/or ceilings to support fixture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited.

IS0538 REV. C 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 4

5

DOWNLIGHT TRIM

21 3

center trim on led module

1 3

WALL WASH

2

WA

LL

WA

LL

tighten wingnut

4

DOWNLIGHT WALL WASH

1 1

TRIM REMOVAL DO NOT PULL ON TRIM FLANGE