7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
1/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 1 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
HANDBOOKHANDBOOKHANDBOOKHANDBOOK
ForForForFor
Outside PlantOutside PlantOutside PlantOutside Plant----Fiber to the HomeFiber to the HomeFiber to the HomeFiber to the Home
(FTTH(FTTH(FTTH(FTTH----OSP)OSP)OSP)OSP)ForForForFor
PT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIA
V 1.0V 1.0V 1.0V 1.0
(June 2013)(June 2013)(June 2013)(June 2013)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
2/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 2 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Contents
PART-I DESIGN & INSTALLATION ........................................................................ 4
FTTH-OSP DESIGN PRINCIPLES .......................................................................... 5
MATERIALS FOR FTTH-OSP (STO - ODP) .......................................................................... 7
MATERIALS FOR FTTH-OSP (HRB: Hign-Rise Building) ......................................................... 8
1. FEEDER CABLE DESIGN ...... 111.1 Google Map .......................................... 111.2 Skema Kabel Feeder .................. 121.3 PetaLokasi Duct & Kabel Feeder .... 15
1.4 Sample Design of Feeder Cable Network ............... 151.5 Core Assignment Diagram ..... 191.6 General Concept for Feeder Cable Design ............... 22
2. DISTRIBUTION CABLE DESIGN . 252.1 Google Map ..... 252.2 Skema Kabel Distribusi .. 25
2.3 Sample Design of Distribution Cable Network ............. 282.4 Branching ODP ............ 322.5 Duct Usage for Distribution Network & Drop-core Installation (Underground) .......................... 33
3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN ............. 343.1 Duct / Buried Section ................ 343.2 Aerial Section .............................. 37
4. CABLE RACK / OTB RACK IN STO BUILDING ... 41
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
3/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 3 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
5. HIGH-RISE BUILDING (HRB) DESIGN ......................................................................... 425.1 Materials for HRB Solution ........................................... 425.2 Design Concept for HRB Solution ................... 435.3 Type of ODC for High-Rise-Building ..... 445.4 Example of Cable Tray/Trunking ............... 455.5 Sample Design: Skema Distribusi ..... 46
5.6 Sample Design: Peta Lokasi Distribusi ............... 47
6. REFERENCE . 506.1 Pondasi ODC-C-144 Splitter ..... 516.2 Pondasi ODC-C-288 Splitter ..... 526.3 Pondasi ODP Pedestal & HH-PIT-60 ............... 536.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300) ............... 54
6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300) .............................................................. 556.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800) .............................................................. 566.7 Installation of ODP Wall ............................................................................ 576.8 Form for Core Assignment Diagram ............................................................................ 596.9 Installation Check Sheet ............................................................................ 636.10 List of Assembly Unit Designator ............................................................................ 67
PART-II ACCEPTANCE TESTING ........................................................................ 73
1. TEST PROCEDURE ................................ 74
2. OPM MEASUREMENT ......................................................................... 862.1 Application of Measurement Forms ................ 872.2 Measurement Forms .............................. 92
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
4/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 4 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
5/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 5 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
FTTH-OSP DESIGN PRINCIPLES (1)
1. FTTH OSP Design Work (Feeder & Distribusion) shall be carried out in accordancewith the frame of this document.
2. LINK BUDGET
1) Descriptions in the Contract:
The Design shall ensure the FTTH OSP System Power Budget of the GPON OLTto ONU (in the configuration of 1:4 Splitter at ODC and 1:8 Splitter at ODP) shallbe 28dB (including the margin of 3dB).
2) Applicable Power Budget in the Project:
Contract Requirement: 28dB - 3dB (Margin) = 25dB (ITU-T G.652D @ WaveLength 1310nm=0.35dB/km)
Requirement by KBB: 25dB - 2dB = 23dB (including 2dB as an Additional
Margin due to an incidental increment of the loss in OSP during an operation) Link Budget to be applied for the Project: 25dB @ 1310nm
We may try however, to keep 23dB @ 1310nm as far as practicable.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
6/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 6 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
FTTH-OSP DESIGN PRINCIPLES (2)
3. FTTH OSP Design shall be composed of the following:
3.1 Feeder Cable Design
1) Google Map per STO
2) Skema Kabel Feeder (Schematic Drawing)
3) Skema Duct (Schematic Drawing)
4) Peta Lokasi Duct & Kabel Feeder (Location Map)
5) Special Design (MH Modification, Duct Bridge etc.)
3.2 Distribution Cable Design
1) Google Map per Lokasi
2) Skema Kabel Distibusi
3) Peta Lokasi Distribusi
4) Special Design (HH Modification, Modified ODP Foundation etc.)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
7/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 7 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Feeder Cable
DC-OF-SM-
12D/24D/48D/
96D/144D/288D
ODC
ODC-C-48/144/288 SplitterNote: ODC-C-48 = Wallmount Type
Pass through closure Type/Designator
for 48core Star/Ring SC-OF-SM-PT-48
for 96core Star/Ring, 144core Star SC-OF-SM-PT-144S
for 144core Ring SC-OF-SM-PT-144R
for 288core Star SC-OF-SM-PT-288S
for 288core Ring SC-OF-SM-PT-288R
Inline closure Type/Designator
for 12c-24c SC-OF-SM-24
for 12c-48c SC-OF-SM-48
for 12c-96c SC-OF-SM-96
for 12c-144c SC-OF-SM-144
for 12c-288c SC-OF-SM-288
STO
ODC
ODP (Aerial)
ODP-SSW-8(1:8 Splitter built-in)
Branching ODP(Pole/Wall Mount)
ODP-PW-BR
Branching ODP(Pedestal)
ODP-PL-BR
ODP (Wall Mount)
ODP-PW-8/16
Distribution Cable
(Aerial)
AC-OF-SM-8/12/24-SC
ODP (Pedestal)
ODPPL-8/16
Distribution Cable(Duct)
DC-OF-SM-8/12/24-SC
Passive Splitter
PS-1-2-ODC/
PS-1-4-ODC
PS-1-8-ODP
Line Guard/Suspension
C-Clamp
Materials for FTTH OSP (STO - ODP)
OTB
TC-OF-SM-
12/24/48/72/96/144
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
8/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 8 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Cable Trunking and Accessories
Splitter for ODC-HRB
PS-1-4-ODC-HRB
Materials for FTTH-OSP (HRB: High-Rise Building)
ODC-HRB (Cabinet)
ODC-HRB-420
ODC-HRB-240
ODC-HRB-180
ODC-HRB(Rack)
ODC-HRB-RACK-480
ODC-HRB-RACK-240
ODC-HRB-RACK-120
19 inch Rack
TC-OF-R-19
or
Indoor Cable
(1-C Low Friction)
IC-OF-SM-1D
ODC-HRB
ODP-HRB
ODP-HRB-16/32 PS-1-8-ODP-HRB
Indoor Cable
(2-C Low Friction)
IC-OF-SM-2D
ROSETTE
RS-IN-SC-1P/
TC-MK-SC-1P
FUSE-CONNECT
ISC-UPC-FD
T-JointCable Trunking Elbow (Flat Angle)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
9/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 9 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
LIST OF MATERIALS AND INSTALLATION MANUALS (1/2) As of: 01-June-2013No. Spec.No. Manual.No. Sub manuals
1 - 5. ESMDDLT000*****K
6 ESMDDLT00028824K
7 - 8. JBT-05166A
9 - 12. ESMDALT0000****K
13-16 ENZDSCDLT0*****K
17 - 20 ENZDSCALT00****K
21-23 ESMDDLT0000****K24 JBT-05027B
25 - 26 JBT-05026-> JBT-05391
49 - 50 JBT-04109A
51 - 52 JBT-04770D
53 - 54 JBT-04109A
55 - 56 PNJHC-1101-54-02(2.8mm)
57 - 75 TS1211-01
76 - 78 PNJBC-0516-54-03 PNJBC-0516-82-01 ODC-C sub manual_130214
79 PNJBC-0516-54-04 PNJBC-0516-82-01 ODC-C sub manual_13021480-81 PNJCS-0013-54-10
82 - 83 PNJCY-0085-54-03 PNJCY-0085-82-01 ODP-CA sub manual_130323
84 - 87 PNJBC-0516-54-06
88 - 89 JEMBO Pedestal + ODP-CA PNJCY-0085-82-01
90 - 95 PNJBC-0516-54-07 PNJBC-0516-82-04 TC-SM sub manual_130225
96 PNJBC-0470-54-04 PNJBC-0470-82-02
97 PNJBC-0472-54-08A
98 PNJBC-0516-54-08
99-101 PNJBC-0516-54-09 PNJBC-0516-82-06102 - 106 PNJBC-0516-54-10
107 - 111 PNJSC-1077-54-03Rev.1
112 - 116 PNJBC-0516-54-11
117 - 121 PNJSC-1077-54-04Rev.1
200 PNJCY-0084-54-02
201 PNJCY-0084-54-01
202 PNJCY-0084-54-04
203 PNJCY-0084-54-03
204 PNJCY-0084-54-05
Manuals will be available upon supply of the material
Manauals not applicable
DC-OF-SM-*D (SM.D D - LT */*T)
DC-OF-SM-*-SC (SM.D D - LT */*T)AC-OF-SM-8-SC (OGGDE-SSW)
Name File
AC-OF-SM-*D (SM.D A - LT */*T)
DC-OF-SM-*C (NZDS.C D - LT */*T)
AC-OF-SM-*C (NZDS.C A - LT */*T)
DC-OF-SM-288D (SM.D D - LT 288/24T)
DC-OF-SM-*D (OG8ETSWBE)
AC-OF-SM-*-SC (OGNM4WTGDE-SSW)
GC-OF-SM-1D (FR-OGINE)
HC-OF-SM-*D (FR-OGNMGDE-SSD)
GC-OF-SM-1D (FR-OGINE)
Patch cord (2.8mm, BIS-B)
Pigtails and Patchcords
ODC-C-* Splitter
ODC-C-48 SplitterODC-CU (FSCO-HHS)
ODP-CA-* for Pole Mount
ODP-A-*
ODP-PL-* (Pedestal_Box+ ODP-CA-* For_Wall_mount)
TC-SM-*
RS-IN-SC-1P (FPB-103A(S))
RS-IN-SC-2P (FPB-302-2SC(PT))
House Hook
Cable cleat
RS-IN-SC-4P (RS-IN-SC-4)
TC-MK-SC-*PS-1-*-ODC (Optical Spitter Module 1 x N Type)
PS-1-*-ODP(PLC Type 1xN Splitter)
PS-2-*-ODC (Optical Spitter Module 2 x N Type)
PS-2-*-ODP (PLC Type 2xN Splitter)
Deadending Wire Vice (C clamp)
Drop Cable Clamp (S Clamp)
Selft-Support Wire Line Guard (Line Guard 2.6mm)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
10/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 10 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
LIST OF MATERIALS AND INSTALLATION MANUALS 2/2) As of: 01-June-2013No. Spec.No. Manual.No. Sub manuals205 PNJCY-0084-54-06
206 PNJCY-0084-54-07
207 PNJCY-0084-54-08
400 - 401 PNJHC-1101-53-01
402 PNJCY-0067-54-18 PNJC-0067-82-04
403 PNJHY-0001-53-11
404 PNJHY-0001-53-10405 PNJHY-0107-53-05
406 PNJHY-0107-54-21Rev.2 JDAA-11-12-0048D
PNJHY-0107-54-21Rev.2 JDAA-11-13-0075
407 PNJBC-0480-54-17
408 PNJBC-0480-54-17
409 PNJBC-0480-54-17
410 B-12F0401 PNJCY-0085-82-03
411 B-12F0401 PNJCY-0085-82-03
412 PNJBC-0085-54-02 PNJCY-0085-82-01413 PNJBC-0085-54-02 PNJCY-0085-82-01
414 JBT-04260B
415 JBT-04260B
416
417
418
419
420
421 PNJBC-0516-54-12 PNJBC-0516-82-09A422 PNJBC-0516-54-12 PNJBC-0516-82-09A
423 PNJBC-0516-54-12 PNJBC-0516-82-09A
424 PNJBC-0516-54-13 PNJBC-0516-82-10
425 PNJBC-0516-54-13 PNJBC-0516-82-11
426 PNJBC-0527-54-07
427 PNJBC-1077-54-03Rev.1
Manuals will be available upon supply of the material
PS-1-8-ODP-HRB
ODP-HRB-16
PS-1-4-ODC-HRB
Pass through closureType4 ( For 288core Ring)
ODC-HRB-420ODC-HRB-240
ODC-HRB-180
ODP-HRB-32
Low Friction Indoor Cable , 2C
Pass through closureType1 ( For 48core Star/Ring )
Pass through closureType2 ( For 96core Star/Ring )
Pass through closureType3 ( For 144core Ring )
Pass through closureType4 ( For 288core Star)
ODP-BR for Branching (3 Hole Type) , Pole mounting type
ODP-BR for Branching (3 Hole Type) , termasuk Dome Pedestal
ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 8 PortODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 16 Port
Low Friction Indoor Cable , 1C
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 4 Port
L-clamp
Flex Band IBT-206
BW-Clamp
Free Bending Optical cord (3mm, BIS-B)
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 1 Port
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 2 Port
ODP-SSW (FSCO-AS-SP(in/splice))
FIELD INSTALLBLE SC CONNECTOR (FAST-SC-SM-09/CO)
FIELD INSTALLBLE SC CONNECTOR (FAST (N) -SC-SM-UNI/GT)FUSION CONNECTOR (Fuseconnect-SC-SF-SM-20/30)
FUSION CONNECTOR (Fuseconnect-SC-DC) for Drop cable
FUSION CONNECTOR (Fuseconnect-SC-LF) for LowFriction cable
Name File
Manauals not applicable
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
11/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 11 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1. FEEDER CABLE DESIGN
A. The Feeder Cable Route shall be planned to utilize the existing duct route asthe first priority so as to minimize the road excavation length.
B. The capacity of Feeder Cables designed/implemented by the previousTOS/PO as well as for the followings shall be taken into account at theFeeder Cable Capacity Planning:
1) AL PRO: Existing Facility such as MSAN, RK, etc.
2) Node B Project
3) GDI: Government Digitalization Network
1.1 GOOGLE MAP1) Nama STO: legend berbentuk Rumah (Warna Merah)
2) Route Feeder: warna Merah3) Nama ODC sesuai dengan Lokasi/Cluster
4) Kapasitas ODC/ Jumlah Homepass
5) Boundary ODC/Lokasi/Cluster dg Boundary Area Potensi
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
12/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 12 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.2 SKEMA KABEL FEEDER
Purpose: Information required for the Feeder Cable Work
A. OTB at STO
OTB to be installed with the symbol Telkom Standard and indicated with the designator in BoQ:
Example: TC-OF-SM-xx (yy)
B. Feeder CableIndication: Black Line (New: 0.6 point, Existing: 0.3 point)
Information:
1) Type (Duct/Aerial) and capacity of cable
2) Length of cable
3) Core Assignment
Note: The younger core number shall be assigned for the far end (the last position) and
spare cores (Cadangan).
Total Quantity of OTB
Type of OTB
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
13/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 13 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
IDENTIFICATION OF FEEDER CABLE
FE XXX 01-01-01 (01-288)
Core No. In Cable
Segment No.
Feeder No.
Code STOCode Feeder Cable
DC-OF-SM-XXX-xxxxM
Cable Length
in meter
No. Of Cores
Type of Cable
Duct Cable: DC-OF-SM
Aerial Cable: AC-OF-SM
Branch-Segment No.
Note:
Cable Line:
New: Tebal (e.g. 6pt.)
Existing: Tipis (e.g. 3pt.)
Identification:
New: Bold FontExistiong: Normal Font
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
14/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 14 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
C. ODC
D. MH/HH/CLOSURE
1) MH/HH: Name of Existing MH/HH or Type of New MH/HH
2) Closure:
a. Straight Joint: SC-OF-SM-xxx
b. Pass-through Joint: SC-OF-SM-xxx-PT
ODC Capacity
ODC No. FA, FB, .......
Code STO
Code ODC
xx PS 1:4 (xxx HP)
Number of Homepass
Code Splitter 1:4
Number of Splitter 1:4
Coordinates Lokasi ODC
ODC-XXX-FA-288
( - )Assigned core to be
terminated
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
15/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 15 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.4 SAMPLE DESIGN OF FEEDER CABLE NETWORK
1.3 PETA LOKASI DUCT & KABEL FEEDER Purpose: Information required for the Civil Work shall be plot on the scaled map
1) SKEMA DUCT
(Refer to 1.4.1)
2) SKEMA KABEL FEEDER
(Refer to 1.4.2)
3) PETA LOKASI
KABEL FEEDER
(Refer to 1.4.3)
Lokasi CC
ODC-ABC-F-288
STO
ABC
24
15.0ABC
01/01
ABC
01/02
ABC
01/03
ABC
01/xx
ABC
01/yy
6 6
6
6
4
ABC
02/02
ABC02/01
ABC
02/xx
100.0 100.0
100.0
100.0
100.0
HH-2
HH-
80
DD-BM-HDPE-1
35.0
HH-1
HH-1
DD-BM-HDPE-1
150.0
DD
-BM-HDPE-BIG-1
DD-BM-
HDPE-
BIG-1
150.0
bbb.
0
Lokasi AA
ODC-ABC-F-144
Lokasi BB
ODC-ABC-F-288
Lokasi DD
ODC-ABC-F-144
JL
JL
JL
aaa.0
DD-BM-
HDPE-
BIG-1
HH-1Ca
bles
lac
k(10)sha
llbeprov
ide
da
t
every
1000m
ofcab
leleng
th.
(Incase
ofDD-B
M-H
DPE
,HH
-1/2s
ha
llbe
ins
talle
d.)
Legend:: Assigned Duct for New Cable
: Vacant Duct: Occupied Duct
Lokasi CC
ODC-ABC-F-288
xx PS 1:4 (yyHP)(241-288)
xxx.xxxxE yyy yyy.yyyy
Lokasi DD
ODC-ABC-F-144
xx PS 1:4 (yyHP)(217-240)
xxx.xxxxE yyy yyy.yyyy
Lokasi AA
ODC-ABC-F-144
xx PS 1:4 (yyHP)(121-144)
xxx.xxxxE yyy yyy.yyyy
Lokasi BB
ODC-ABC-F-288
xx PS 1:4 (yyHP)(73-120)
xxx.xxxxE yyy yyy.yyyy
STO ABCTC-SM-144 (3)
FE-ABC-01-01 (01-144)
DC-OF-SM-144D m
FE-ABC-01-01-01 (121-144)
DC-OF-SM-24D m
FE-ABC-01-02(01-120)
DC-OF-SM-144D
m
FE-ABC-01-02-01 (73-120)
DC-OF-SM-48D m CAD(01 72)
FE-ABC-02-01(01-288)
DC-OF-SM
-288D
m
DC-OF-SM
-288D
m
FE-AB
C-02-
02
(01-2
40)
CAD(01 216)
FE-ABC-02-01-01 (241-288)
DC-OF-SM-48D m
FE-ABC-02-02-01 (217-240)
DC-OF-SM-48D m
JL
JL
JL
ABC
01/02
ABC
01/yy
DC-OF-SM-288D
m
FE-ABC-02-
02
(01-240)
Cable Slack (10m) shall be
placed every 1000m of
cable span and/or thelocation where the future
demand is expected.
STO
ABC
100.0
ABC01/01
DD-BM-HDPE-1
150.0
DD-BM-HDPE-1
35.0
HH-
80
HH-2
HH-1
HH-1
DD-BM-HDPE-BIG-1
150.0
JL
JL
JL
Lokasi BB
ODC-ABC-F-288
Lokasi AA
ODC-ABC-F-144
Lokasi CC
ODC-ABC-F-288
Lokasi DD
ODC-ABC-F-144
DD-BM-1
10.0
DD-BM-1
10.0
DD-ROD-1
15.0
DD-ROD-1
xxxx.0
ABC01/02
ABC01/03
ABC01/xx
DD-BM-HDPE-
BIG-1
bbb.
0
aaa.
0
DD-BM-HDPE-
BIG-1
HH-1
ABC02/03
ABC
02/01
ABC
02/xx
ABC01/xx
ABC
01/xx
ABC01/yy
ABC02/02
DD-ROD-1
1.0
DD-ROD-1
1.0
DD-ROD-1
1.0
DD-ROD-1
xxx.0
DD-ROD-1
1.0
DD-ROD-1
1.0
DD-ROD-1
xxx.0
DD-ROD-1
1.0
DD-ROD-1
1.0
DD-ROD-1
xxx.0
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
16/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 16 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.4.1 SKEMA DUCT
STO ABC
24
15.0
ABC01/01ABC01/02
ABC
01/03
ABC01/xx
ABC01/yy
6
6
664
ABC
02/02
ABC
02/01
ABC
02/xx
100.0
100.0
100.0100.0100.0
HH-2HH-80
DD-BM-HDPE-1
35.0
HH-1HH-1
DD-BM-HDPE-1
150.0
DD-BM-HDPE-
BIG-1
DD-BM-HDPE-
BIG-1
150.0bbb.0
Lokasi AA
ODC-ABC-F-144
Lokasi BB
ODC-ABC-F-288
Lokasi CC
ODC-ABC-F-288Lokasi DD
ODC-ABC-F-144
JL
JL
JL
aaa.0
DD-BM-HDPE-
BIG-1
HH-1
Cable slack (10) shall be provided at every 1000m
of cable length. (In case of DD-BM-HDPE, HH-1/2
according to Page 23, 1.6.3 shall be installed.)
Legend:
: Assigned Duct for New Cable
: Vacant Duct
: Occupied Duct
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
17/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 17 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.4.2 SKEMA KABEL FEEDER
Lokasi CC
ODC-ABC-F-288xx PS 1:4 (yyHP)
(241-288) xxx.xxxx
E yyy yyy.yyyy
Lokasi DD
ODC-ABC-F-144xx PS 1:4 (yyHP)
(217-240) xxx.xxxxE yyy yyy.yyyy
Lokasi AA
ODC-ABC-F-144xx PS 1:4 (yyHP)
(121-144)
xxx.xxxxE yyy yyy.yyyy
Lokasi BB
ODC-ABC-F-288xx PS 1:4 (yyHP)
(73-120)
xxx.xxxxE yyy yyy.yyyy
STO ABC
TC-SM-144 (3)
FE-ABC-01-01 (01-144)
DC-OF-SM-144D m
FE-ABC-01-01-01 (121-144)
DC-OF-SM-24D m
FE-ABC-01-02 (01-120)
DC-OF-SM-144D m
FE-ABC-01-02-01 (73-120)
DC-OF-SM-48D m
CAD
(01 72)
FE-ABC-02-01 (01-288)
DC-OF-SM-288D mDC-OF-SM-288D
m
FE-ABC-02-02
(01-240)CAD
(01 216)
FE-ABC-02-01-01 (241-288)
DC-OF-SM-48D m
FE-ABC-02-02-01 (217-240)
DC-OF-SM-48D m
JL JL
JL
ABC
01/02ABC01/yy
DC-OF-SM-288D
m
FE-ABC-02-02
(01-240)
Cable Slack (10m) shall be
placed every 1000m of cable
span and/or the location where
the future demand is expected.
(Note: Do not show on drawing)
( )
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
18/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 18 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.4.3 PETA LOKASI KABEL FEEDER
STO
ABC
ABC
01/01
DD-BM-HDPE-1
150.0DD-BM-HDPE-1
35.0
HH-80
HH-2
HH-1 HH-1
DD-BM-HDPE-
BIG-1
150.0
JL
JL
JL
Lokasi BB
ODC-ABC-F-288Lokasi AA
ODC-ABC-F-144
Lokasi CC
ODC-ABC-F-288
Lokasi DD
ODC-ABC-F-144
DD-BM-1
10.0
DD-BM-1
10.0
DD-ROD-1
15.0m
ABC
01/02ABC
01/03
ABC
01/xx
DD-BM-HDPE-
BIG-1
bbb.0aaa.0
DD-BM-HDPE-
BIG-1
HH-1
ABC02/02
ABC
02/01
ABC02/xx
ABC
01/xxABC
01/xx
ABC
01/yy
ABC02/03
DD-ROD-1xxx.0m
DD-ROD-1100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0m
DD-ROD-1
100.0mDD-ROD-1
xxx.0m
DD-ROD-1
xxx.0m
1. FE-ABC-01
2. FE=ABC-02
Note:
In case if plural cables
will be installed in one
(1) route, Cable No. tobe installed shall be
indicated.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
19/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 19 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.5 CORE ASSIGNMENT DIAGRAM1. CORE ASSIGNMENT DIAGRAM shall be prepared prior to draw the SKEMA KABELas a tool so as to
arrange the core assignment of the feeder cable easily. (Not for submission purpose)
2. CORE ASSIGNMENT DIAGRAM shall be prepared per each FEEDER CABLE.
3. The higher number of core (e.g. 288 in 288-core cable) shall be assigned from the nearest ODC, and the
youngest number shall be assigned for the furthest ODC or CAD (Spare core).
START
FEEDER CABLE ROUTE PLAN:
=> Draft for Skema Feeder
1. SKEMA DUCT EXISTING shall be referred as the
basic information for the Feeder Cable Route Plan.
2. Plot all ODCs TO BE FED BY THE CABLE
together with its capacity along the existing duct
route.
3. Where the existing duct is not available, new duct
construction or DD-BM-HDPE shall be planned.
4. Plot all prospected/ potential locations includingAl-Pro, MSAN, GDI etc. along the expected
feeder cable route.
Decision of Network
Configuration:
1.Ring
2.Star/Bus
SUM UP the required
number of fiber cores:
1.ODC-144: 24 cores
2.ODC-288: 48 cores
Decision of Feeder Cable Capacity:
1.Required number of cores 96 96C
2.Required number of cores 97 , 144 144
3.Required number of cores 145 , 288 288
4.Required number of cores 288 288 +
another cable according to the required capacity
Preparation of
CORE ASSIGNMENT
DIAGRAM
END
FLOW OF CORE ASSIGNMENT DIAGRAM PREPARATION
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
20/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 20 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.5.1 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (1): STAR/BUS TOPOLOGY
SKEMA KABEL FEEDER
(Reference for Main Information)
Lokasi AA
ODC-288(241 288)
Lokasi CC
ODC-144(169 192)
Lokasi DD
ODC-144(145 168)
Lokasi BB
ODC-288
(193 240)
CAD (72)
(01 72)
Lokasi EE
ODC-288
(97 144)CAD (24)
(73 96)
(01 288)
(288) (288) (288)
(01 240) (01 192)
(145 192)
(01 72)
(96)
(48) (145 168)
(24)
(48)
(97 144)(48)
(193 240)
(48)(241 288)
(24)
(169 192)
STO ABC
TC-OF-SM-144 (2)
01 - 24
25 - 48
49 - 72
73 - 96
97 - 120
121 - 144
145 - 168
169 - 192
193 - 216
217 - 240
241 - 264
265 - 288
Lokasi AA
ODC-288
(241 288)
Lokasi BB
ODC-288
(193 240)STO ABC
Lokasi CC
ODC-144
(169 192)
Lokasi DD
ODC-144
(145 168)
CAD
(73 96)
CAD (72)
(01 72)
Lokasi EE
ODC-288
(97 144)(288)
(96)
(48)
(48)
(24) (24)
(48) LEGEND:
: Joint Closure
: Fusion Splicing
: Cable (Core)(XX)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
21/101
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
22/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 22 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.6 GENERAL CONCEPT FOR FEEDER CABLE DESIGN1.6.1 ODC SPEC. (Non-HRB Type)
ODC
typeDesignator
Splitter
(1:4)Maximum HP
Feeder
(input Fiber core)
Number of Cable Entry
(Input+Output)
48
(pole)
ODC-C-48 Splitter Max. 6pcs 6x32=192Star ; 12C
Ring ; 24C
4
96
(pedestal)ODC-C-96 Splitter Max. 8pcs 8*32=256
Star ; 12C
Ring ; 24C8
144
(pedestal)ODC-C-144 Splitter Max. 18pcs 18x32=576
Star ; 24C
Ring ; 48C12
288
(pedestal)ODC-C-288 Splitter Max. 36pcs 36x32=1152
Star ; 48C
Ring ; 96C12
576(pedestal) ODC-C-576 Splitter Max. 72pcs 72x32=2304 Star ; 96CRing ; 192C 24
1.6.2 FEEDER CABLE SPEC.
Fiber Count Number of Tubes Number of Fiber/Tube Tube Diameter Outer Diameter Bending Radius
(20 x OD)
12C 2 6 2.1mm 12.8mm 25.6cm
24C 4 6 2.1mm 12.8mm 25.6cm
48C 4 12 2.5mm 13.9mm 27.8cm
96C 8 12 2.5mm 15.6mm 31.2cm
144C 12 12 2.5mm 19.1mm 38.2cm
288C 24 12 2.5mm 22.1mm 44.2cm
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
23/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 23 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.6.3 HDPE PIPE/HANDHOLE for FEEDER CABLEIn case when the existing duct is not available and new duct (HDPE) will be installed, the following shall be taken intoconsideration:
1) Feeder Cable with the capacity 288-core:
HDPE BIG/SUBDUCT BIG shall be used.
Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.
2) Feeder Cable with the capacity 144-core
HDPE 33/40/SUBDUCT shall be used. Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.
3) Feeder Cable with the capacity 96-core or less
HDPE 33/40/SUBDUCT shall be used.
Hand-hole Type HH-2 (L=1200 x W=600 x D=1300) shall be used for all locations
1.6.4 HANDHOLE for ODC
At ODC location, HANDHOLE shall be installed:
1) Type HH-1 (L=1700 x W=1250 x D=1300):
Where the Jointing Closure from the Feeder Cable with 288/144-core.is installed including the locationwhere slack is located for future jointing.
2) Type HH-2 (L=1200 x W=600 x D=1300):
Where Handhole shall be located on the carriage way.3) Type HH-80 (L=800 x W=800 x D=800):
Where Handhole will be located on the Green Area (Taman) in the housing area (Perumahan) and whereno jointing closure will be located.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
24/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 24 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1.6.5 PASS THROUGH CLOSURE for FEEDER CABLE
Through Cable
Type
Model No. (3M)
48core 2179CS Type 1 : 24core tray (1)
Size ; 447mm x 175mm x 107mm
96core, 144core 2179C Type 2 : 24core tray (1)
Type 3 : 24core tray (2)
Size ; 557mm x 215mm x 119mm
288core 2178LS Type 4 : 24core tray (2)
Type 5 : 24core tray (4)
Size ; 557mm x 216mm x 203mm
Option: 24core tray , Re-entry kit
Consultation shall be necessary in case when the other optional items are required.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
25/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 25 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
2. DISTRIBUTION CABLE DESIGNMaximum Usage of Distribution Cable shall be 80% of the cable capacity:Maximum No. of ODP: No. of Spare Core (CADANGAN)
1) 8-Core Cable: 6 (Only for Branch Section) 2 CORE CAD.
2) 12-Core Cable: 10 2 CORE CAD.
3) 24-Core Cable: 20 4 CORE CAD.
2.1 GOOGLE MAP1) ODC (Name/Capacity)
2) Distribution Cable Route
3) Location of ODP
2.2 SKEMA KABEL DISTRIBUSI
Purpose: Information required for the Distribution Cable Work1) ODC
ODC Capacity
ODC No. FA, FB, .......
Code STO
Code ODC
ODC-XXX-FA-288
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
26/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 26 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
2) DISTRIBUTION CABLE
DSXXX-FE 01-01-01/01-01-01 (01-24)
Core No. In Cable
Segment No.
Label Feeder (Feeder No., Segment No.)Code STO
DC-OF-SM-24SC-xxM
Cable Length in meter
Designation for Easy to Split Cable
No. Of Cores
Type of Cable
Duct Cable: DC-OF-SMAerial Cable: AC-OF-SM
Code Distribution CableDistribution No.
Branch-Segment No.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
27/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 27 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
3) ODP
FA/D01/xx/yy
(xx)
No. No.
Number of Splitter 1:8
1: ODC-8
2: ODC-16
ODP No.
Note: 1. Continuous number starting from D01:
example: 10 ODP on D01, ODP on D02 shall be
started from No.11.
2. ODP No. shall be given from the far most ODPfrom ODC location.Distribution Cable No.
ODC No.
Core No. to be terminated at ODP
e.g. from 01 to 24
The largest No. of care shall be allocated to the nearest
ODP from ODC.
House No. in front ofODP Location
Coordinates Lokasi ODP
Note: Grounding shall be placed at the last ODP for each distribution cable.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
28/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 28 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
2.3 SAMPLE DESIGN OF DISTRIBUTION CABLE NETWORK
1) SKEMA KABEL DISTRIBUSI
2) PETA LOKASI KABEL DISTRIBUSI
2.3.1 CASE-1: UNDERGROUND/DUCT CABLE
ODC-F-144
xx PS 1:4 (yyHP)
DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-10) DSABC-FE-01-01/01-03 (01-09) DSABC-FE-01-01/01-xx (01-05)
F/D01/07/02
(11-12)N ...
E .......
N ...
E .......
F/D01/06/01
(10)
N ...
E .......
F/D01/05/01(09)
ODP-PW-BRN ...
E .......
F/D01/01/02
(03-04)
N ...
E .......
CAD
(01-02)
DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m
3 4 9 10 16 17 31
F/D01/04/01
(08)
DSABC-FE-01-01/01-03-01 (08)
DC-OF-SM-8-SC ..m
N ...
E .......
JL. ..
HH-2
ODC-F-144
xx PS 1:4
(yyHP)
DD-BM-HDPE-1 ..mDD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-1 ..m
DD-BM-1 ..m
DD-BM-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-1 ..m
DD-BM-HDPE-1 ..m
DD-BM-1 ..m
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30
31
32
DD-BM-HDPE-1 ..m
F/D01/07/02 F/D01/06/01F/D01/05/01
ODP-PW-BR F/D01/01/02
F/D01/04/01
JL. ..
Note:
At the BRANCHING, the core
assignment and the ODP No. shall be
in accordance with the rule below.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
29/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 29 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
STO ABC NAMA LOKASI Cluster AA (ODC-F-144)DISTRIBUTION
CABLE No.D-01 CAPACITY 12-CORE
FEEDER SEGMENT DISTRIBUTION SEGMENT
OTB
Port No.
ODC
PORT No.
SPLITTER 1:4 ODC TRAY CORE
No.No. Port No. PORT No.
49 1 1
1
1
1 1
2 2 2
3 3 3
4 4 4
50 2 2
1 5 5
2 6 6
3 7 7
4 8 8
51 3 3
1 9 9
2 10 10
3 11 11
4 12 12
7 6 5 4 3 2
3) CORE ASSIGNMENT DIAGRAM (For CASE-1)
1
CAD
8-C
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
30/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 30 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
2.3.2 CASE-2: AERIAL CABLE1) SKEMA KABEL DISTRIBUSI
2) PETA LOKASI KABEL DISTRIBUSI
ODC-F-144
xx PS 1:4 (yyHP)
DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-11) DSABC-FE-01-01/01-03 (01-10) DSABC-FE-01-01/01-xx (01-05)
F/D01/08/01
(12)N ...
E .......
N ...
E .......
F/D01/07/01
(11)
N ...
E .......
F/D01/06/01
(10)
ODP-PW-BRN ...E .......
F/D01/01/01
(05)
N ...E .......
CAD
(01-04)
AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m
3 4 9 10 16 17 31
F/D01/05/01
(09)
DSABC-FE-01-01/01-03-01 (09)
AC-OF-SM-8-SC ..m
N ...
E .......
JL. ..
HH-2
ODC-F-144
xx PS 1:4
(yyHP)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30
31
32
F/D01/08/02 F/D01/07/01F/D01/06/01
ODP-PW-BR F/D01/01/01
F/D01/05/01
JL. ..
BC-PP 3m 30m 45m 45m 45m
45m
25m.m
LEGEND
: New Pole
: Existing Pole Branching ODP(1 x 1:8 Splitter)
ODP Aerial(1 x 1:8 Splitter)
30m
Note:
At the BRANCHING, the core
assignment and the ODP No. shall be
in accordance with the rule below.
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
31/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 31 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
3) CORE ASSIGNMENT DIAGRAM (For CASE-2)
STO ABCABCABCABC NAMA LOKASI Cluster AA (ODC-F-144) DISTRIBUTION
CABLE No.D-01 CAPACITY 12-CORE
FEEDER SEGMENT DISTRIBUTION SEGMENT
OTB
Port No.
ODC
PORT No.
SPLITTER 1:4 ODC TRAY
CORE No.No. Port No. PORT No.
49494949 1111 1111
1
1111
1 1
2 2 2
3 3 3
4 4 4
50505050 2222 2222
1 5 5
2 6 6
3 7 7
4 8 8
51515151 3333 3333
1 9 9
2 10 10
3 11 11
4 12 12
ODP No. 15 34 2678
CAD
12-C 12-C
8-C
HANDBOOK f
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
32/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 32 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Main Cable
(SCPT-8/12/24-core)
ODP Pedestal/Wall
Capacity: 8 or 16
ODP Pedestal/WallCapacity: 8 or 16
Branching Cable(SCPT-8-core)
Branching ODP(1 x 1:8 Splitter)
Designator:
ODP-PL-BR
2.4 BRANCHING ODP
1) Underground Cable
(Pedestal/Wall Mount)
Branching ODP shall be used in case when the several ODP locations are not suitable to be fed by the main cable but
independent cable installation is also not efficient due to the limited number of ODP (Less than 8 ODP).
Branching ODP:
1)Branching ODP is applicable for both underground as well as aerial distribution cable design.
2)Type of ODP is Cabinet type to be mounted on: WALL, POLE and PEDESTAL.
3)The cable to be branched from the main cable shall be of 8-Core.
4)The number of ODP on branched cable shall be less than 8.5)The branching ODP is able to accommodate only one (1) unit of 1:8 Splitter.
2) Aerial Cable
(Pole Mount)
Main Cable
(SSW-8/12/24-core)
ODP Aerial
Capacity: 8
ODP AerialCapacity: 8Branching Cable
(SCPT-8-core)
Branching ODP(1 x 1:8 Splitter)
Designator:
ODP-P/W-BR
HANDBOOK f
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
33/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 33 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
2.5 DUCT USAGE FOR DISTRIBUTION NETWORK &DROP-CORE INSTALLATION (UNDERGROUND)
ODC ODP/ ODP ODP
1)DD-BM-HDPE
2)BC-TR-1.5 + DD-HDPE
ODP (HH-PIT-60) HH-PIT-40/
HH-PIT-40 HH-PIT-40
1) BC-TR-0.6 + DC-SD-1 BigHH-PIT-60
HH-PIT-40
HH-PIT-40
HH-PIT-40 - Premises
1) BC-TR-0.4 + PP-OF-OUT(PVC )
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
34/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 34 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN
1) Bila ditemukan jalan buntu pada perumahan dengan jalak Drop core
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
35/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 35 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
2) Bila ditemukan jalan buntu pada perumahan dengan jalak Droop core >100 meter makadiperbolehkan menggunakan ODP Branch dari kabel distribusi untuk kabel yang akan menuju ke
ODP dengan jumlah branch sesuai denga HP, Gambar Terlampir :2) When you find a blind alley which need drop cable more than 100 m, it is allowed to use the ODP Branch from the
main distribution cable according to the quantity of HP. Please see the illustration below.
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
36/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 36 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
3) Bila ditemukan jalan tidak buntu pada perumahan maka penarikan kabel distribusi dapat dilakukansecara mengelilingi perumahan yang letak ODP di sesuaikan dengan jumlah HP, Gambar Terlampir :3) When it is not a blind alley, span of the cable should pass around the complex and placement of ODP should be
adjusted according to the HP. Please see the illustration below.
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
37/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 37 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
3.2 AERIAL SECTION1) Sample Design based on Duct Cable Design Standard
=> (Some consideration due to particularity of the aerial cable shall be required.)
6.5m 45m
6.5m
30m
45m 45m
40m
45m45m
45m11m
45m
45m
25m
25m
6.5m
35m45m
45m45m
Road width
more than 6m
Road width
less than 6mAC-OF-SM-12-SC
AC-OF-SM-8-SC
AC-OF-SM-8-SC
AC-OF-SM-12-SC
ODP-BR
ODP-BR
Note: Location where specialconsideration is required due
to a particularity of the aerialcable installation
: ODC
: ODP
1) ODP-SSW-8
2) ODP-BR
: HH-2/HH-80
: New Pole 7m/9m
LEGEND
C-CLAMP x 2
Detail for Riser Part
SSW CABLE
Cable part shall be
protected with Spiral
for outdoor use (Black
color)
Detail forRiser Part
Note: Prior to plotting ODP on the map, ODP Boundary (Max. 8HP) shall be designated so that the numberof ODP and its location can be planned efficiently.
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
38/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 38 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
2) Sample Design based on Particularity for Aerial Cable
: Additional Pole for
Drop Core
LEGEND for Additional Item
: Drop Core Run
6.5m
45m
6.5m
40m
45m
45m
40m
45m
45m
45m11m
45m
45m
25m
25m
6.5m
35m
45m
45m
45m
Road widthmore than 6m
Road width
less than 6m
30m
35m
10m
15m
25m
30m
30m
40m
35m
25m
35m
Detail "Drop-A"
Detail "Drop-B" Detail "Drop-C"
Note: Location where special
consideration is taken due to
a particularity of the aerial
cable installation
Some particular consideration required for
Aerial Cable Design
1. Additional pole(s) may be required for the
drop cable installation. (Actual installationof additional poles shall be decided in
accordance with contract with the
developper/owner)
2. Road width less than 6m can be crossed by
the drop cable as far as the road traffic will
not be disturbed otherwise new pole shall
be installed.
3. Location of ODP shall be decided so that:1) Drop cable can be installed along SSW
cable.
2) Drop cable can be installed indipendently
for one (1) span (2 spans at maximum)
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
39/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 39 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
C-CLAMP x 2
SSW CABLE
Cable part shallbe protected with
Spiral for outdoor
use (Black color)
3) Details of SSW Installation
A. Details of Riser Part B. ODP-SSW Location
10cm
ODP-SSW-8
B-1. With C-CLAMP
C. Cable Allignment
As far as it is practical, thecable shall be installed so
that the suspension wire is
always above the cable part.
Suspension Wire
Cable Part
At the cable laying, turns inthe cable shall be released
by turning the cable winding
while making the 8-figure.
50mm
Bend
150mm remove sheath
D. C-LAMP E. Line Guard Installation
30cm
Line Guard
L= 51cm
ODP-SSW-8
B-2. With LINE GUARD
SUSPENSION CLAMP
25cm
< 120
LINE GUARD shall be installed where:1. One (1) in every three (3) poles in the
straight line.
2. At the pole beside the ODP-SSW is
installed except the location where C-CLAMP is installed.
Caution:LINE GUARD shall be fixed and the Suspension
Wire at C-CLAMP shall be bent ONLY after all
ODP-SSW installation have been completed
and the cable allignment has been confirmed
so that no turn is contained in the cable span.
: SSW Cable (Japan)
LEGEND
: C-Clamp (Japan)
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
40/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Page 40 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Drop Cable
(Aerial)
HC-OF-SM-2D
4) Details of Drop-Core Solution
Detail "Drop-A"
Messenger wire from drop cable to pole or1.2mm galvanized steel wire with sheath coating
Detail "Drop-B"
Detail "Drop-C"
: S-Clamp (Japan)
LEGEND
: D-Clamp (Japan)
: BW-Clamp (Local)
FUSE-CONNECT
ISC-UPC-FD
ROSETTE
RS-IN-SC-1P/
TC-MK-SC-1P
Details of "Home Connect"
ODP-SSW-8
ODP-PL/PW-
8/16Drop Cable
(Underground)
GC-OF-SM-2D
Wire Grip 3/8"
with double nut
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
41/101
FTTH OSP (PT TELKOM INDONESIA)
Page 41 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
4. CABLE RACK/OTB RACK IN STO BUILDING
Note:
1. The cable routing in the STO building shall be
measured so as to estimate the cable length
from the duct entrance at the Cable Chamberuntil the OTB.
2. In case when the new rack shall be provided, the
rack to be installed shall be of same type and
the same color with the existing one.
3. In the decision of the location of 19 rack
installation, well coordination with DBB, Telkom
Area and/or WASPANG is required.
4. When the location of new 19 Rack installation
is fixed, the designated location on the floor
shall be clearly marked with an adhesive tape
and a permanent markeras:
FTTH OSP
JF DJAFa
5. The maximum number of unit of TC-OF-SM-144
to be accommodated in the 19 Rack with
Height of 2.20m shall be FIVE (5).
CABLE
CHAMBER
MDF
ROOM OTB ROOM/
TRANSMISSION
ROOM
19R
ACKH=2200
Max.5xTC-OF-SM-144
FEEDER
CABLE
STO BUILDING
CABLE RACK
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
42/101
FTTH OSP (PT TELKOM INDONESIA)
Page 42 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
5. HIGH-RISE BUILDING (HRB) DESIGN
No. Designator ApplicationNo. of Splitter
(Max.)
Number of PortHome Pass
Accommodated (80%)In Out Total
1. ODC for HRB/MDU (Approx.)
1.1 ODC-HRB-180 (*) Cabinet/ Wall 1:4 x 36 36 144 180 900
1.2 ODC-HRB-240 (*) Cabinet 1:4 x 48 48 192 240 1200
1.3 ODC-HRB-420 (*) Cabinet 1:4 x 84 84 336 420 2200
1.4 ODC-HRB-RACK-120 (**) 19" Rack Mount 1:4 x 24 24 96 120 600
1.5 ODC-HRB-RACK-240 (**) 19" Rack Mount 1:4 x 48 48 192 240 1200
1.6 ODC-HRB-RACK-480 (**) 19" Rack Mount 1:4 x 96 96 384 480 2500
2. ODP for HRB/MDU (Installed) (Max.)
2.1 ODP-HRB-16 (*) Wall Mount1:8 x 1 - 8 8
161:8 x 2 - 16 16
2.2 ODP-HRB-32 (*) Wall Mount1:8 x 3 - 24 24
321:8 x 4 - 32 32
3. 2-C Low Friction Indoor Cable
3.1 IC-OF-SM-1D
Distribution/ Drop-core
1-Core (G657A) Low Friction Indoor Cable for DISTRIBUTION-CABLE
3.2 IC-OF-SM-2D 2-Core (G657A) Low Friction Indoor Cable for DROP-CABLE1-Core connected with Fuse-Connect (ISC-UPC-FD), 1-Core for spare
4. ROSETTE SC Adapter
4.1 RS-IN-SC-1P 1Indoor Rosette4.2 RS-IN-SC-2P 2 To be discussed when necessary (***)
4.3 RS-IN-SC-4P 4 To be discussed when necessary (***)
4.4 TC-MK-SC-1P 1
Indoor Rosette (Buried inwall)
4.5 TC-MK-SC-2P 2 To be discussed when necessary (***)
4.6 TC-MK-SC-4P 4 To be discussed when necessary (***)
5.1 MATERIAL FOR HRB SOLUTION
Note (*): New Item (Specifications have been accepted by TELKOM)(**): New Item (Specifications shall be subject to concurrence by TELKOM)
(***): To be discussed with DBB TELKOM when 2P or 4P Rosette is required by the Developer
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
43/101
FTTH OSP (PT TELKOM INDONESIA)
Page 43 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1-Core Low Friction Indoor Cable for
1x 1:8 Splitter with Field Installable SC Connector
(Fuse-connect) x 1pc at both ends
ODC-HRB-
1) 180
2) 240
3) 420
ODC-HRB-RACK-
1) 120
2) 2403) 480
Feeder Cable:
1) For ODC-HRB-180: 24/48C
2) For ODC-HRB-240: 48C
3) For ODC-HRB-480: 96C
ODP:
1) ODP-HRB-16: Up to 16 HP (1or 2 x 1:8 Splitter)
Size: H=330 x W=260 x D=130
2) ODP-HRB-32: Up to 32 HP (3 or 4 x 1:8 Splitter)
Size: H=412 x W=312 x D=140
ODP-
HRB
Cable Tray/Shaft/Ladder
Rosette: TC-MK-SC-xP
(1-Port/2-Port/4-Port)
2-Core Low Friction Indoor Cable
with Field Installable SC Connector
(Fuse-connect) x 1pc at both ends
ODP-
HRB
4) For ODC-HRB-RACK-120: 24C
5) For ODC-HRB-RACK-240: 48C
6) For ODC-HRB-RACK-480: 96C
5.2 DESIGN CONCEPT FOR HRB SOLUTIONDESIGN CONCEPT FOR HRB
1. ODC shall be selected among all types
according to the site situation as well as
number of Home Pass of the target
building.2. ODP shall be selected among three (3)
types according to the number of Home
Pass and the Floor Layout.
3. 2-Core Low Friction Indoor Cable shall
be used between ODC and ODP.
4. One (1) Low Friction Indoor Cable shall
be connected ODC Port with one (1) 1:8
Splitter of ODP i.e.:1) ODP-HRB-16: One (1) or two (2) Low
Friction Indoor Cable:
a. 1 x 1:8 Splitter: 1 Low Friction Cable
b. 2 x 1:8 Splitter: 2 Low Friction Cables
2) ODP-HRB-32: Three (3) or four (4) Low
Friction Indoor Cables:
a. 3 x 1:8 Splitter: 3 Low Friction Cables
b. 4 x 1:8 Splitter: 4 Low Friction Cables
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
44/101
FTTH OSP (PT TELKOM INDONESIA)
Page 44 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
5.3 Type of ODC for High-Rise-Building1) CABINET TYPE 2) RACK MOUNT TYPE
(To be mounted in the Closed Rack H=1.20m)
H= 770
W=555
D=310
ODC-HRB-180
Application: Wall/Floor
D=360
H= 1450
W=750
ODC-HRB-240/420Application: Floor
W=428
H= 275
D=302.3
ODC-HRB-RACK-120
Application: 19" Rack
W=428
D=302.3H= 445
ODC-HRB-RACK-240
Application: 19" Rack
W=428
D=302.3
H= 890
ODC-HRB-RACK-480
Application: 19" Rack
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
45/101
FTTH OSP (PT TELKOM INDONESIA)
Page 45 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
5.4 Example of Cable Tray/Trunking
1) HORIZONTAL RUN
(a) On the Cable Tray
Cable Tray
Cable Trunking
(b) Direct Attachment to the Building Wall
2) VERTICAL RUN
ODP-
HRB
Elbow (Flat Angle)
T-Joint
Cable Trunking
HANDBOOK for
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
46/101
FTTH OSP (PT TELKOM INDONESIA)
Page 46 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
5.5 SAMPLE DESIGN: SKEMA DISTRIBUSI
ODC ABC BUILDING
F.../STO/HRB-xxx
xx PS 1:4 (xxx HP)S 6
E 106 ...
x IC-OF-SM-1D __mx IC-LF-OF-SM-1D __m
x IC-OF-SM-1D __m
2 IC-OF-SM-1D__m
x IC-LF-OF-SM-1D __m
1 IC-LF-OF-SM-1D __m 2 IC-OF-SM-1D __m
x IC-OF-SM-1D __m
x IC-OF-SM-1D __m
F/P01-02/1/2
ODP-HRB-16
F/P03/2/1
ODP-HRB-16
(Note: Not "8")
ODC No.
Code STO
"HRB"-"Capacity"
180
240
420
No. of Splitter No. of Home Pass
No. of Splitter 1:8ODP No.
ODC Port No.
Each No. to be given for Each 1-Core
Indoor CableODC No.
Specify "Tower" and/or
"Shaft" according to the
Building Layout.
F/P04-05/3/2
ODP-HRB-16
2: No. of Indoor Cable to be installed and
terminated to ODP
__m: Cable Length from ODC to ODP
Tower A/
Shaft No.1
Floor-xx
Floor-yy
Floor-zz
Descriptions for ODC
ODC XXX (Name of Building)
2. F... /STO /HRB-(RACK)-xxx
3. xx PS 1:4 (xxx HP)
4. Coordinates
1. F/ P-03/ 2/ 1
Descriptions for ODP
2. ODP-HRB-xx
Type of ODP: ODP-HRB-16, 32 (See Note above.)
Note:
Type of ODP-HRB is 2:
1. ODP-HRB-16: No. of 1:8
Splitter= 1 or 2
2. ODP-HRB-32: No. of 1:8
Splitter= 3 or 4
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
47/101
FTTH OSP (PT TELKOM INDONESIA)
Page 47 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
5.6 SAMPLE DESIGN: PETA LOKASI DISTRIBUSI
1) PETA LOKASI KABEL DISTRIBUSI (Vertical View)
Tower A
F/P03/2/1
ODP-HRB-16Note: Not "8"
F/P04-05/3/2
ODP-HRB-16
ODC ABC BUILDING
F.../STO/HRB-xxx
xx PS 1:4 (xxx HP)
F/P01-02/1/2
ODP-HRB-16
Cable Shaft No.1 Cable Shaft No.2
Cable Tray/Trunking to be installed
e.g. Cable Tray W=100mm x 35m
1
LEGEND
: ODC-HRB
: ODP-HRB
: Cable Tray/Trunking
(New)
2
: Rosette (1-Port)
: Rosette (2-Port)
: Cable Tray/Trunking
(Existing)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
48/101
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
49/101
FTTH OSP (PT TELKOM INDONESIA)
Page 49 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Table-1: List of Port Management
ODC Port
No.
Distribution
Cable No.
ODPUnit No.
Drop Cable
Length (m)No./Floor Splitter No. Port
1 D01
8
1
1 1 30.0
2 2 18.0
3 3 10.0
4 25 55.0
5 26 50.0
6 27 45.0
7 28 40.0
8 29 35.0
2 D02 2
1 11
12
30
31
32
33
34
35
6
7
8
3) LIST OF PORT MANAGEMENT & DROP-CORE LENGTH
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
50/101
FTTH OSP (PT TELKOM INDONESIA)
Page 50 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
51/101
FTTH OSP (PT TELKOM INDONESIA)
Page 51 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.1 PONDASI ODC-C-144 Splitter
Keterangan:
Pondasi dan lantai kerja berlapis keramik.
1. Pondasi: Keramik 20 x 20, warna biru
2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biru
310mm
103
5mm
555mm
463
170
500
600
660
360150 150
ODC Foundation: A-A(Not to scale/ Unit: mm)
98.5 98.5
75 85mm
Drill:14mm/ d= 75 85mm(Expansion Bolt: M8 x 150)
1100
463
G.L
52.5 52.5555
ODC Foundation: B-B
(Not to scale/ Unit: mm)
440
150 150140
115 115170
75 85mm
Drill:14mm/ d= 75 85mm
(Expansion Bolt: M8 x 150)
G.L
31065 65
ODC Foundation: Top View(Not to scale/ Unit: mm)
150
150
140
440
150 150360
660
440
135
135
1
70
660
98.598.5
463
Drill:14mm/ d= 75 85mm
A A
B
B
(Expansion Bolt: M8 x 150)
ODC Foundation
Conduit Connection
(Not to scale/ Unit)
R > 500mm
W=600
(HH-2)
Handhole
Type:HH2
5 x HDPE 33/40
(B-B Side)
Approx.30cm or less
Approx. 30cm
G.L.
- 200
0
- 1500
- 1000
HandholeType:HH-80
W=800(HH-80)
- 600
Special Attention:
Cable Slack shall be placed only in
HANDHOLE/HH-PIT and never belocated in the ODC Foundation.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
52/101
FTTH OSP (PT TELKOM INDONESIA)
Page 52 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.2 PONDASI ODC-C-288 Splitter
150
150
140440
165 165520
850
440
120
120
200
850
119 119612
Drill:18mm/ d= 60 80mm
ODC Foundation: Top View(Not to scale/ Unit: mm)
A A
B
B
(Expansion Bolt: M12 x 150)
320mm
1450m
m
750mm
ODC Mount and
Location of Anchor
Bolt
612
200
ODC Foundation: A-A
(Not to scale/ Unit: mm)
G.L
500
600
850
520165 165
119 119
60 80mm
Drill:18mm/ d= 60 80mm
(Expansion Bolt: M12 x 150)
1100
612
50 50750
Keterangan:
Pondasi dan lantai kerja berlapis keramik.
1. Pondasi: Keramik 20 x 20, warna biru2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biruODC Foundation: B-B
(Not to scale/ Unit: mm)
440
150 150
120 120200
60 80mm
Drill:18mm/ d= 60 80mm
(Expansion Bolt: M12 x 150)G.L
60 60320
140
Conduit Connection
(Not to scale/ Unit)
R > 500mm
W=600(HH-2)
HandholeType:HH2
5 x HDPE 33/40
(B-B Side)
Approx.30cm or less
Approx. 30cm
G.L.
- 200
0
- 1500
- 1000
HandholeType:HH-80
W=800(HH-80)
- 600
ODC Foundation
Special Attention:Cable Slack shall be placed only in
HANDHOLE/HH-PIT and never be
located in the ODC Foundation.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
53/101
FTTH OSP (PT TELKOM INDONESIA)
Page 53 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
500
100 300 100
TELKOM
500
100
100
300
300
PVC 4"
Sub-duct BIG
500
700
200
150
150
100
100
Distance in accordance with
the site situation.
Jaak sesuai kondisi lapangan.
150 150400
700
900
100 100
Sub-duct BIG
PVC 4"
PVC 4" for
Drop Cable
L=300
PVC 4" for
Distribution Cable
L=300
450
150
900
600150 150
150
600
150
900
700
150
500
200150 150
100 100
150
100
80
220
H
600-H
600
500
100 100 300
150 150400
700
LARGE RADIUS ELBOW
PVC 4"
(WAVIN D-LL 4" or Equivalent)
PVC4"
L=
650
Distance in accordance with
the site situation.Jaak sesuai kondisi lapangan.
6.3 PONDASI ODP PEDESTAL & HH-PIT-60
Cable Installation Method between HH-PIT-60 and ODP
Distribution Cable Installation
shall cautiously be carried out
so that the Bending Radius of
20cm shall be secured.
Note H: Height above ground
shall be minimum 10cm. Actualheight shall be in accordance
with the site condition.
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
54/101
FTTH OSP (PT TELKOM INDONESIA)
Page 54 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
1300
250
150
900
250 1000
1250
288-C cable
R= 44.2mm
+- 150cm
557mm
450625 625
1700
1300
250
150
+-90cm
450625 625
PASS-THROUGH CLOSURE ARRANGEMENT IN HH-1
(288-C Loose Tube Cable / 3M Type 2178LS)
BESI 70 x 50 x 3
150 1501250
1550
100 1001350
200 200950
1550
Hole 20mm
10mm x 125mm
POT B - B
12mm x 125mm
PVC 4" x 4
L= 300
1
5
0
1
5
0
1
5
01
5
0
10mm x
125mm
BETON: 225kg/cm
150 1501700
2000
200
150
1300
1650
600 600100 100
200 200 200200 200 200
10mm x 125mm
10mm x 125mm
POT A - A
600
200 200 200
12mm x 125mm
150
150
L=300
TE
L
K
OM
TE
L
K
OM
TE
LK
O
M
150
150
150
950
1550
A A
B
B
100200200200 200 200200
2000
200 200100
1350
3 x 600 = 1800
150
TELKOM
200
TELKO
M
TELKO
M
6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
55/101
FTTH OSP (PT TELKOM INDONESIA)
Page 55 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
BESI 70 x 50 x 3
150 150600
900
100 100700
150150
400
900
Hole
20mm
10mm x 125mm
POT B - B
PVC 4" x 4
L= 300
150
150150
150
T
E
LK
O
M
100 225 225 100200 225225 200
1500
150
150
150
300
900A A
B
B
T
E
L
K
O
M
2 x 650 = 1300
700
150
PVC 4" x 4
L= 300
150 1501200
1500
200
150
1
300
1650
650 650100 100
225 200 225225 200 225
150
10mm x 125mm
10mm x 125mm
POT A - A
150
L=300
6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300)
BETON: 225kg/cm
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
56/101
FTTH OSP (PT TELKOM INDONESIA)
Page 56 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800)
150150 800
1100
150
10mm x 125mm
10mm x 125mm
200
150
800
1150
100
200
450
1100
125
150
L=300
450 100
125 200125 125
POT A - A
Hole 20mm
150
150150 PVC 4" x 4
L= 300
BESI 70 x 50 x 3
10mm x 125mm
150 150800
1100
200
150
800
11
50
1100
100 100900
150 150600
150
POT B - B
B
T
E
LK
OM
1100
150
100
1100A A
B
1100
PVC 4" x 4
L= 300
900
T
E
LK
OM
150
100
60
0
100
125
100
200
450
1100
450
125 125 200 125
BETON: 225kg/cm
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
57/101
( )
Page 57 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
G.L.
Approx.2.20m
10cm
30cm10c
m30cm
Approx.
10cm
Clampsshallbeattached
Approx.@
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
58/101
( )
Page 58 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Flex. Pipe
OD=25mmSteel flexible inside
HH PIT-60
150
Flex-pipe
R300
Approx.
200
Appro
x. 100
Approx. 100
Approx. 100
Flex-pipe R300
Flex-pipe
R300
Flex-pipe
R300
Flex-pipeR300
PVC Simple
Socket for OD
25mm Pipe
PVC/High-Impact
Conduit OD 25mm
PVC/High-Impact
Conduit OD 25mm
Pipes shall be buried in the wall.
Pipe space shall be filled with
concrete after ODP installation.
150
Approx.
200
100
50
Approx.
100
HH PIT-60
Note:
In case when pipes shall be buried in the building wall due to the
requirement by the developer, the following points shall be taken into
account for the installation.
1. HH-PIT-60 shall be installed in front of ODP location.
2. Flexible Pipe with steel (OD 25mm) shall be used at the bending part of
conduit.
3. Bending Radius of Flexible Pipe shall be more than 300mm.4. PVC/High-Impact Pipe (OD 25mm) shall be used at the straight part of
conduit.
5. PVC Simple Socket for OD 25mm Pipe shall be used at all jointing part.
6. Pipe space of wall shall be filled with concrete after installation of ODP.
(ODP termination work shall be done prior to the pipe fixing and concrete
work.)
7. The wall shall be restored to the original condition and painted with the
same color with the original wall.
MOM/BA shall be made (to be signed by the PIC of the developer) for theconfirmation of the requirement.
2 x PVC 50
(L=200)
Pipes shall be buried in the wall.
Pipe space shall be filled withconcrete after ODP installation.
Drop Cable
6.7 INSTALLATION OF ODP WALL (2)(In case pipe shall be buried in the wall)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
59/101
Page 59 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.8 FORM FOR CORE ASSIGNMENT
6.8.1 FEEDER CABLE (STAR TOPOLOGY: 24 CORE BASE)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
60/101
Page 60 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.8.2 FEEDER CABLE (STAR TOPOLOGY: 12 CORE BASE)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
61/101
Page 61 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.8.3 FEEDER CABLE (RING TOPOLOGY)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
62/101
Page 62 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.8.4 DISTRIBUTION CABLE
No. Port No. PORT No.
CORE ASSIGNMENT DIAGRAM (DISTRIBUTION CABLE)
CAPACITY -CORE
OTB
Port No.
SPLITTER 1:4CORE No.
ODC
PORT No.
ODC TRAY
DISTRIBUTION CABLE No.
4
3
4
1
2
D-
2
3
4
1
2
3
4
1
2
3
3
4
1
2
3
4
1
2
1
19
20
21
22
23
24
13
14
15
16
17
18
7
8
9
10
11
12
1
2
3
4
5
6
FEEDER SEGMENT
1
2
3
4
1
2
3
4
5
6
7
8
9
10
STO
11
12
5
6
7
8
DISTRIBUTION SEGMENT
ODP No.ODP No.ODP No.ODP No.
NAMA LOKASI
9
10
11
12
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
63/101
Page 63 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
TipeProduct:ODC-C-144
Tgl.Instalasi
NamaLokasi
NamaInstaller
Category
Items
1.Aksesoris
Cableband(M)
Cableband(L)
Spira
lTube
Compound
Cabletie
Asse
mblymanual
PVC
tape
2.PondasiODC
Baut
expansiontidakkendur
3.LubangKabelMasu
k(Feeder&Distribusi)
4.Cableclamp
Clam
puntuktensionMembertidakkendur
CableBandtidakKendur
5.RuteLooseTube
Tidak
adasmallbending(diamete
r>60)
tidak
terjepitdengantutuptray
Tidak
adasmallbending(diamete
r>60)
tidak
terjepitdengantutuptray
7.RutePigtaildalamTray
Arah
Rute(bentukS)
Tidak
adasmallbending(diamete
r>60)
tidak
terjepitdengantutuptray
8.InstalasiSplittermo
dul
rutes
esuaipetunjukmanual
Tidak
adasmallbending(diamete
r>60)
tidak
salingtersangkutdanmudah
diurai
10.SCconnectorpatching
Kone
ktortercolokdenganbenar(sampaibunyiklik)
diperiksaoleh
:
(Sitemanager)
Catatan
Arah
danPosisiSplitterharusben
ar(Input:bawah;
Output:atas)
Peng
gunaanCompoundharusrapat(tidakadacelah)
InstallationCheckSheet
pcs
pcs
pcs
pc
pcs
9.RutekabeldariSplitterkeTray
pc
pc
Che
ck
*2buahkunciODC
harussudah
diterimasitemanager
*cek
sisaaksesorisyangdiperlukan
untukinstalasikabe
lberikutnyadanuntuk
maintenance
6.RuteFiberdidalam
Tray
6.9 INSTALLATION CHECK SHEET
6.9.1 INSTALLATION CHECK SHEET: ODC-C-144
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
64/101
Page 64 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.9.2 INSTALLATION CHECK SHEET: ODC-C-288TipeProduk:ODC-C-288
Tgl.Instalasi
NamaLokasi
NamaInstaller
Category
Items
1.Aksesoris
Cable
band(M)
Cable
band(L)
SpiralTube
Compound
Cable
tie
Assem
blymanual
PVCtape
2.PondasiODC
Bautexpansiontidakkendur
3.LubangKabelMasuk(Feeder&Distribusi)
4.Cableclamp
Clamp
untuktensionMembertidakkendur
Cable
BandtidakKendur
5.RuteLooseTube
Tidakadasmallbending(diameter
>60)
tidakterjepitdengantutuptray
Tidakadasmallbending(diameter
>60)
tidakterjepitdengantutuptray
7.RutePigtaildalamTray
ArahR
ute(bentukS)
Tidakadasmallbending(diameter
>60)
tidakterjepitdengantutuptray
8.InstalasiSplittermod
ul
rutese
suaipetunjukmanual
Tidakadasmallbending(diameter
>60)
tidaks
alingtersangkutdanmudahd
iurai
10.SCconnectorpatching
Konektortercolokdenganbenar(sa
mpaibunyiklik)
Diperiksaoleh
(Sitemanager)
Catatan
Arahd
anPosisiSplitterharusbenar(Input:kiri;
Output:kanan)
*2buahkunciODCharussudah
diterimasitemanage
r
InstallationCheckSheet
Checkp
cspcs
pcspc
pcs
*cek
sisaaksesoris
yangdiperlukan
untukinstalasikabel
berikutnyadanuntuk
maintenance
6.RuteFiberdidalamTray
9.RutekabeldariSplitterkeTray
pcpc
Pengg
unaanCompoundharusrapa
t(tidakada
celah)
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
65/101
Page 65 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
ProductType:ODP-CA-8/16-WP
InstallationDate:
InstallationSite:
InstallerName:
Category
Items
Check
1.Accessory
Cabletie
pc
s
Expansionscrew
sets
Dropcablefixingclamp
pc
s
Bukumanual
pc
PVCtape
pc
2.InstalasiSplitter
Arah:inp
ut:kiri;output:kanan,label
terlihat
PosisiSp
litter:No1palingatas
Tidakada
smallbending(diameter>60
)
KabelTidakterjepitatautersangkutjikadibuka
PosisiKonektor
4.LubangTempatkabelmasuk
5.clampKabel
Clampun
tukTensionmemberTidakkendur
Clampun
tukkabeltidakkendur
6.RutekabelSCPTPas
sthrough
Tidakada
smallbending(diameter>60
)
TidakterjepitdantersangkutjikaODPd
ibuka
7.ClampdanruteSCPT
yangditerminasi
pastikanpenggunaankabelTiesditigatitik
Tidakada
smallbending(diameter>60
)
tidakterje
pitdantersangkutjikaODPdibuka
8.RuteFibersetelahSplicing
Tidakada
smallbending(diameter>60
)
tidakterjepitdantersangkutjikaODPdibuka
Diperiksaoleh:
(Sitemanager)
Catatan
pemasangantempatmasukkabelharus
rata,tidakmiring
Installatio
nChecksheet
*1buahkunciODPharussudah
diterimasitemanager
tidakada
celah(penggunaansolasiatau
grommet
harusdap
atmenutupcelah)
adadisebelahkanan,
BariskonektorpalingbawahuntukSplitterno.1
*ceksisaaksesorisya
ngdiperlukan
untukinstalasikabelberikutnyadanuntuk
maintenance
3.instalasioutputSplitterpadapanel
Adapter
6.9.3 INSTALLATION CHECK SHEET: ODP-PL/PW-8/16
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
66/101
Page 66 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
Pro
ductT
ype:T
C-S
M-144
Installa
tionD
ate:
Installa
tion
Site:
InstallerN
am
e:
Category
Item
s
1.Ak
sesoris
Cable
band(M)
Cable
band(L)
Pla
stic
Tube
Screw
andn
ut
Cable
tie
Buk
uM
anual
PV
Cta
pe
2.
Clam
pk
abel
Clam
p
untukT
en
sionm
em
berTid
ak
ken
dur
CableB
andtidakk
en
dur
3.R
utek
abelL
oosetub
e
Tid
ak
a
dasm
all
ben
din
g
(diam
eter>
60)
kabelT
idak
terje
pit
atauters
an
gk
utjika
traydile
pas
Tid
ak
a
dasm
all
ben
din
g
(diam
eter>
60)
Tid
ak
terje
pit
atauters
an
gk
utjikacov
ertraydi
buk
a
5.R
ute
Pig
tail
padaTra
y
Rutem
emben
tukh
uruf
S
Tid
ak
a
dasm
all
ben
din
g
(diam
eter>
60)
Tid
akT
erjepit
atau
ters
an
gk
utjikacover
traydib
uk
a
Dip
erik
saoleh
(Sitem
an
ager)
Catatan
pcpc
Ch
eck
4.R
utek
abel
dalamtra
y
*Cek
sisaaksesoris
yangdiperlukan
untukinstalasikabel
berikutnyadanuntuk
maintenance
Installa
tion
Ch
eck
Sh
eet
p
cs
p
cs
p
cs
sets
p
cs
6.9.4 INSTALLATION CHECK SHEET: TC-SM-144
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
67/101
Page 67 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (1/6)
A
KABEL&PENYAMB
UNGAN
1
DC-OF-SM-12D
PengadaandanpemasanganKabelD
uctFiberOptik
SingleMode12coreG652D(termasukperijinan
PEMDA,PU,Warga)
meter
2
DC-OF-SM-24D
Idem24core
meter
3
DC-OF-SM-48D
Idem48core
meter
4
DC-OF-SM-96D
Idem96core
meter
5
DC-OF-SM-144D
Idem144core
meter
6
DC-OF-SM-288D
Idem288core
meter
7
DC-OF-SM-432D
Idem432core
meter
8
DC-OF-SM-960D
Idem960core
meter
9
AC-OF-SM-12D
PengadaandanpemasanganKabelU
daraFiber
OptikSingleMode12coreG652D(termasuk
perijinanPEMDA,PU,Warga)
meter
10
AC-OF-SM-24D
Idem24core
meter
11
AC-OF-SM-48D
Idem48core
meter
12
AC-OF-SM-96D
Idem96core
meter
13
DC-OF-SM-12C
PengadaandanpemasanganKabelD
uctFiberOptik
SingleMode12coreG655C(termasukperijinan
PEMDA,PU,Warga)
meter
14
DC-OF-SM-24C
Idem24core
meter
15
DC-OF-SM-48C
Idem48core
meter
16
DC-OF-SM-96C
Idem96core
meter
17
AC-OF-SM-12C
PengadaandanpemasanganKabelU
daraFiber
OptikSingleMode12coreG655C
(termasuk
perijinanPEMDA,PU,Warga)
meter
18
AC-OF-SM-24C
Idem24core
meter
19
AC-OF-SM-48C
Idem48core
meter
20
AC-OF-SM-96C
Idem96core
meter
21
DC-OF-SM-8-SC
PengadaandanpemasanganKabelD
uctFiberOptik
SingleMode8coreG652D,"Easyto
split"
(termasukperijinanPEMDA,PU,War
ga)
meter
22
DC-OF-SM-12-SC
Idem12Core
meter
23
DC-OF-SM-24-SC
Idem24Core
meter
24
AC-OF-SM-8-SC
PengadaandanpemasanganKabelU
daraFiber
OptikSingleMode8coreG652D,"E
asytosplit"
(termasukperijinanPEMDA,PU,War
ga)
meter
25
AC-OF-SM-12-SC
Idem12Core
meter
26
AC-OF-SM-24-SC
Idem24Core
meter
27
SC-OF-SM-24
Pengadaandanpemasanganalatsam
bung(cabang/
lurus)untukFiberOptikkapasitas12-24core
pcs
28
SC-OF-SM-48
Idem12-48core
pcs
29
SC-OF-SM-96
Idem12-96core
pcs
30
SC-OF-SM-144
Idem12-144core
pcs
31
SC-OF-SM-288
Idem12-288core
pcs
32
OS-SM-1Eks
PenyambunganKabelOptikSingleModekap1core
dengancarafusionsplice
core
33
OS-SM-6
PenyambunganKabelOptikSingleModekap6core
dengancarafusionsplice
pcs
34
OS-SM-12
Idemkap12core
pcs
35
OS-SM-24
Idemkap24core
pcs
36
OS-SM-48
Idemkap48core
pcs
37
OS-SM-96
Idemkap96core
pcs
38
OS-SM-144
Idemkap144core
pcs
39
OS-SM-288
Idemkap288core
pcs
40
AB-OF-SM-2D
PengadaandanpemasanganAirBlo
wnCableOptik,
SingleMode2core,G652D(termasukperijinan
PEMDA,PU,Warga)
meter
41
AB-OF-SM-4D
Idem4core
meter
42
AB-OF-SM-8D
Idem8core
meter
43
AB-OF-SM-12D
Idem12core
meter
44
AB-OF-SM-24D
Idem24core
meter
45
AB-OF-SM-48D
Idem48core
meter
46
AB-OF-SM-72D
Idem72core
meter
47
AB-OF-SM-96D
Idem96core
meter
48
AB-OF-SM-144D
Idem144core
meter
49
GC-OF-SM-1D
PengadaandanpemasanganDropC
ableFODuct
/underground1CoreSingleMode,G.657
meter
50
GC-OF-SM-2D
idem2core
51
HC-OF-SM-1D
PengadaandanpemasanganDropC
ableFOatas
tanah/aerial1CoreSingleMode,G.6
57
meter
52
HC-OF-SM-2D
idem2core
meter
53
IC-OF-SM-1D
PengadaandanpemasanganIndoorCableFOSingle
Mode1core,G.657
meter
54
IC-OF-SM-2D
Idem2core
meter
KETERANGAN
NO
DESIGNATOR
URAIAN
PEKERJAAN
SATUAN
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02
68/101
Page 68 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N
6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (2/6)
55
PC-SC-2-BI
Patchcord2meter,BendInsensitive(SC/APCTo
SC/UPC)dariRosetkeONT,G.657
pcs
56
PC-SC-5-BI
Patchcord5meter,BendInsensitive(SC/APCTo
SC/UPC)dariRosetkeONT,G.657
pcs
57
PC-SC-2
Patchcord2meter,(SC/APCToSC/APC),G.657
pcs
58
PC-SC-5
Patchcord5meter(SC/APCToSC/APC),G.657
pcs
59
PC-SC-10
Patchcord10meter(SC/APCToSC
/APC),G.657
pcs
60
PC-SC-20
Patchcord20meter(SC/APCToSC
/APC),G.657
pcs
61
PC-FC-20
Patchcord20meter(FC/APCToFC/APC),G.657
pcs
62
PC-SC-30
Patchcord30meter(SC/APCToSC
/APC),G.657
pcs
63
PC-FC-30
Patchcord30meter(FC/APCToFC/APC),G.657
pcs
64
PC-SC-40
Patchcord40meter(SC/APCToSC
/APC),G.657
pcs
65
PC-FC-40
Patchcord40meter(FC/APCToFC/APC),G.657
pcs
66
PC-SC-2
Patchcord2meter,(SC/UPCToSC/UPC),G.657
pcs
67
PC-SC-5
Patchcord5meter(SC/UPCToSC/UPC),G.657
pcs
68
PC-SC-10
Patchcord10meter(SC/UPCToSC
/UPC),G.657
pcs
69
PC-SC-20
Patchcord20meter(FC/UPCToFC/UPC),G.657
pcs
70
PC-FC-20
Patchcord20meter(SC/UPCToSC
/UPC),G.657
pcs
71
PC-SC-30
Patchcord20meter(FC/UPCToFC/UPC),G.657
pcs
72
PC-FC-30
Patchcord30meter(SC/UPCToSC
/UPC),G.657
pcs
73
PC-SC-40
Patchcord40meter(FC/UPCToFC/UPC),G.657
pcs
74
PC-FC-40
Patchcord40meter(SC/UPCToSC
/UPC),G.657
pcs
75
PC-FC-40
Patchcord40meter(FC/UPCToFC/UPC),G.657
pcs
76
ODC-C-144Splitter
PengadaandanpemasangankabinetODC(Outdoor)
kap144coredenganspaceuntuksplitermodular
termasukmaterialadaptorSC/UPC,pigtail,pondasi
berlapiskeramik,lantaikerja,patokp
engaman(5
buah),berikutpelabelan
pcs
77
ODC-C-288Splitter
PengadaandanpemasangankabinetODC(Outdoor)
kap288coredenganspaceuntuksplitermodular
termasukmaterialadaptorSC/UPC,pigtail,pondasi
berlapiskeramik,lantaikerja,patokp
engaman(5
buah),berikutpelabelan
pcs
78
ODC-C-576Splitter
PengadaandanpemasangankabinetODC(Outdoor)
kap576coredenganspaceuntuksplitermodular
termasukmaterialadaptorSC/UPC,pigtail,pondasi
berlapiskeramik,lantaikerja,patokp
engaman(5
buah),berikutpelabelan
pcs
79
ODC-C-48Splitter
PengadaandanpemasanganODC-P
ole(Outdoor)
withspaceforpassivespliter,adaptorSC/UPC
kap
48core,berikutpelabelan
pcs
80
ODP-CU-8
PengadaandanpemasanganODPty
peClosure
UndergroundKap8corewithspaceforsplitter,
AdapterSC/UPC
pcs
81
ODP-CU-16
idem16core
pcs
82
ODP-CA-8
PengadaandanpemasanganODPty
peClosure
AerialKap8coreberikutspacepasiv
espliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
83
ODP-CA-16
PengadaandanpemasanganODPty
peClosure
AerialKap16coreberikutspace2pasivespliter
(1:8),adapterSC/UPC,berikutpelabe
lan
pcs
84
ODP-A-8
PengadaandanpemasanganODPty
peIndoor/wall
Kap8coreberikutspacepasivespliter(1:8),adapter
SC/UPC,berikutpelabelan
pcs
85
ODP-A-16
PengadaandanpemasanganODPty
peIndoor/wall
Kap16coreberikutspace2pasives
pliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
86
ODP-A-24
PengadaandanpemasanganODPty
peIndoor/wall
Kap24coreberikutspace3pasives
pliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
87
ODP-A-48
PengadaandanpemasanganODPty
peIndoor/wall
Kap48coreberikutspace6pasives
pliter(1:8),
adapterSC/UPC,berikutpelabelan
pcs
88
ODP-PL-8
PengadaandanpemasanganODP(Pilar)kap8
coretermasukpigtail,berikutspace1
splitter(1:8),
pelabelan.
pcs
89
ODP-PL-16
PengadaandanpemasanganODP(Pilar)kap16
coretermasukpigtail,berikutspace2
splitter(1:8),
pelabelan.
pcs
KETERANGAN
NO
DESIGNATOR
URAIAN
PEKERJAA
N
SATUAN
HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
7/24/