2 0 1 4 0 1 1 6 _ E N E R G I U M . C O . L T D
[GNT System Introduction]
Ver.3.1
3) GNT System Process
4) GNT System Benefits
1) GNT System Outline
0. CONTENTS
2) GNT System Structure
2
5) GNT System Details
6) Contact us
GNT system
1. GNT System Outline
This phlebotomy assistant system helps prevent medical accidents, and cuts patient waiting times.
3
GNT system Role
This system automatically provides medical technicians with essential items required for a phlebotomy
(a tube with a specimen label attached, a specimen label, a patient identification label) based on the
phlebotomy information recorded in the Hospital Information System (HIS, LIS, OCS, EMR).
1. GNT System Outline
4
GNT system Benefits
With the GNT system, hospitals can prevent medical accidents, cut waiting time, and cut blood
collection room operating costs, improving convenience for both medical technicians and patients,
allowing the hospital to reach customers with a more modern image.
1. GNT System Outline
5
GNT system
2. GNT System Structure
* GNT system software
* Reception PC is an existing PC at the hospital with the hospital’s HIS (LIS, OCS, EMR) installed.
Reception PC*
Queue number
ticket printer MWT PC
Barcode scanner
Control PC
BA(Barcode Applicator)
TTT(Test Tube Transfer)
MWT (Medic Work Table)
Segment
6
Essential components for GNT system operation
BA (Barcode Applicator)
BA (Barcode Applicator) attaches a label to a tube,
and transfers the labeled tube to TTT.
TTT(Test Tube Transfer)
TTT prints out a patient queue number label and other labels and
places them in a tray with an already labeled tube. The tray is then
transferred to each MWT.
MWT (Medic Work Table)
MWT prepares a tray for the phlebotomy.
GNT system Hardware Components
2. GNT System Structure
BA(Barcode Applicator)
TTT(Test Tube Transfer)
MWT (Medic Work Table)
7
GNT system Hardware Components
Control PC
A PC with GNT DB and other major programs installed including
control, setting, statistics programs allowing general GNT system
control.
Queue number ticket printer
Queue number ticket printer prints patient queue number
tickets.
Essential components for system operation
Barcode scanner
A barcode scanner transfers barcode information printed on
the patient queue number ticket to the MWT PC.
MWT PC
A PC with GNT MWT installed helps medical staff carry out the
phlebotomy and record the results without error.
2. GNT System Structure
8
WLD(Waiting List Display)-Optional
A device displaying a list of waiting patients to indicate wait status.
QND(Queue Number Display)-Optional
A display device that plays a tone and indicates the patient queue
number to call the next patient to the MWT.
GNT system Hardware Components
2. GNT System Structure
Essential components for system operation
9
System Software Components
Collection program
A program that collects and processes patient and phlebotomy
information from the hospital's HIS and transfers the processed
information.
Statistics program
A program that provides users various statistical graphs
enabling easy access to the phlebotomy data in the GNT
storage.
Essential software components for system operation
Setting program
A program that assists general performance, user registration,
and tasks related to settings, such as label design form
configuration.
Control program
A program that displays system storage information on a screen
and gives a print command to the BA(Barcode Applicator)
*Besides the programs indicated above, the main ‘System Storage’ program is included in the product.
2. GNT System Structure
10
System Software Components
MWT program
A program for easy and convenient checking and recording
(information update) of phlebotomy information
WLD(Waiting List Display)-Optional
A program displaying a list of waiting patients to indicate the
wait status.
QND(Queue Number Display)-Optional
A program that plays a tone and shows the patient queue
number to call the next patient to the MWT.
*Besides the programs indicated above, the main ‘System Storage’ program is included in the product.
2. GNT System Structure
Essential software components for system operation
11
3. GNT System Process
Reception
(at reception desk)
Phlebotomy
(at phlebotomy desk)
STEP1 : Phlebotomy reception
STEP2 : Issue patient queue number ticket
STEP3 : Supply of essential phlebotomy apparatus*
STEP4 : Call out a patient for phlebotomy
STEP5 : Patient (customer) identification
STEP6: Phlebotomy
*A tube with specimen label attached, specimen label, and patient identification label
STEP7: Patient (customer) identification and phlebotomy conclusion
12
Phlebotomy process with the GNT system
1
2
3
4
6 5
7
3. GNT System Process
13
STEP1: Phlebotomy Reception
1-1 When a customer requests a phlebotomy, a staff member
checks the customer information received from the HIS.
(Customer information already stored in the HIS)
1-1 *This is an example HIS
(LIS, OCS, EMR) screen.
The actual screen may
differ in different hospitals.
3. GNT System Process
Reception (at a reception table)
Check
14
STEP2 : Issue phlebotomy queue number ticket
2-1 On pressing the 'Receipt' button on the HIS, the queue number
ticket information print command is transferred to the Queue
number ticket printer via the Collection program.
Reception (at a reception table)
2-2 The Queue number ticket printer prints out a Patient queue
number ticket.
Click
2-2
2-1
3. GNT System Process
*This is an example HIS
(LIS, OCS, EMR) screen.
The actual screen may
differ in different hospitals.
15
Phlebotomy (at phlebotomy desk)
STEP3: Supply of essential phlebotomy apparatus*
3-1 Press Tray call button.
3-2 A tray containing a tube with a specimen label attached,
a specimen label, and a patient identification label is sent to the MWT
tray outlet.
3-1
3-2
*Phlebotomy apparatus
3. GNT System Process
16
STEP4 : Call patient for phlebotomy
4-1 Read the printed patient identification label with the Barcode
scanner. 4-2
4-2 Segment calls out the waiting patient.
(The number display and tone for sequential phlebotomy queue tickets)
4-1
3. GNT System Process
Phlebotomy (at phlebotomy desk)
17
STEP5: Patient identification
5-1 Read the patient queue number ticket with the Barcode
scanner.
5-2 The MWT program displays an 'identification confirmed' message.
*This is an example MWT screen.
The actual screen may vary in different hospitals.
5-1
5-2
3. GNT System Process
Phlebotomy (at phlebotomy desk)
Check
18
STEP6: Phlebotomy
6-1 Phlebotomy
6-1
3. GNT System Process
Phlebotomy (at phlebotomy desk)
19
STEP7: Patient (customer) identification and
phlebotomy conclusion
7-1 Read the printed patient identification label with the Barcode
scanner.
7-2 The MWT program displays 'Phlebotomy finished' message.
Check
7-1
7-2
3. GNT System Process
Phlebotomy (at phlebotomy desk)
20
GNT system prevents medical accidents.
4. GNT System Benefits
With the GNT system, tasks that were done manually can be automated.
This prevents medical malpractics due to human error, such as switched specimens or tubes.
;;
21
GNT system cuts down waiting time.
With GNT system, phlebotomy process becomes simple.
This cuts down the waiting time for customers (patients).
4. GNT System Benefits
22
GNT system reduces costs.
With the GNT system, phlebotomist can focus on the phlebotomy process itself.
This improves the phlebotomists' performance, leading to overall reductions in phlebotomy room operating costs.
4. GNT System Benefits
23
GNT system enhances convenience.
With the GNT system, the phlebotomist has a more convenient and efficient environment.
Thus the phlebotomist is freed from other trivial work.
4. GNT System Benefits
24
GNT system enhances image.
With the GNT system, the hospital can present an image as a modern hospital.
The fast and convenient medical service will leave customers (patients) with the positive image
of visiting a modern hospital.
4. GNT System Benefits
25
GNT7 Specifications
5. GNT System Details
Description Specifications
Capacity Processes around 150 patients per hour
Tube loading capacity/ No. of Inlets 100EA per inlet / 6 inlet
Tube supply method Direct tube pallet supply
Compatible tube types 13/75, 13/100, 16/100 (BD, GREINER, AMPULAB, INSEPACK, IMPROVE)
Time to provide the first tube 4 sec
Time to provide the first two tubes 7 sec
Label printing method Thermal printing
Label printing resolution 203dpi, 300dpi (optional)
Barcode type 10 types
Barcode length 5 grades
Available languages English, Korean, Chinese, Thai, Turkish
Available text fonts 2 types(A type, B type)
Available text sizes Width : 1~4 point , Height : 1~4 point
Available text formats Bold, Underline, Reverse
Minimum line thickness 0.125mm
Available line type Horizontal, Vertical
Compatible label sizes Width : 50mm , Length : 28~38mm / 3000 label (per 1 label roll )
26
GNT7 Specifications
5. GNT System Details
Description Specifications
Equipment unit size
Barcode Applicator 780mm x 455mm x 1436mm
Test Tube Transfer 1180mm x 595mm x 801mm
Medic Work Table 1100mm x 908mm x 1905mm
Equipment unit weight
Barcode Applicator 150kgf
Test Tube Transfer 115kgf
Medic Work Table 121kgf
Input power AC 100-240V 50/60Hz
Certificates CE, KCC
Protocol Protocol for HIS(LIS, OCS, EMR) and GNT interface provided by Energium
Interface RS 232, TCP/IP (Optional)
Tube Transfer Conveyor type Optional module
MWT Partition Optional module
Foot switch Optional module
27
GNT7 Dimensions
5. GNT System Details
4,480
59
5
1,3
34
1,4
36
80
1
1,9
05
28
GNT5 Basic type
Medium GNT series model.
Model used in medium hospitals.
Single tube supply can accommodate 400 tubes.
GNT7 Basic type
Large GNT series model.
Model used in large general hospitals.
Single tube supply can accommodate 600 tubes.
GNT series
GNT5 Conveyor type
GNT5 series conveyor model.
Model collects user (phlebotomist) tubes
so they can focus on the actual phlebotomy process.
GNT7 Conveyor type
GNT7 series conveyor model.
Model collects user (phlebotomist) tubes
so they can focus on the actual phlebotomy process.
5. GNT System Details
29
Conveyor
Model collects GNT system user (phlebotomist) tubes so they can focus on the actual phlebotomy process.
5. GNT System Details
IN OUT
30
Installation sites (general hospital)
5. GNT System Details
Seoul National University Hospital Seoul National Univ. Bundang Hospital
Severance Hospital in shinchon Seoul St. Mary's Hospital Incheon St. Mary's Hospital
Chonnam Univ. Hospital Dong-A Univ. Hospital Ulsan Univ. Hospital Pusan National Univ. Hospital Ajou Univ. Hospital Haeundae Paik Hospital
Gyeongsang Univ. Hospital Kangwon Univ. Hospital Chungnam Univ. Hospital Soon Chun Hyang Univ. Hospital Korean Cancer Hospital
South Korea
31
Installation sites (medical center, health promotion association)
5. GNT System Details
Jeju Seogwipo Medical Center Chungju Medical Center Cheongju Medical Center
Daeheon Chapter Chungbuk Chapter Incheon Chapter
Gyeonggi Chapter Seoul Eastern Chapter Seoul Gangseo Chapter
Daegu Chapter
Gyeongbuk Chapter Jeju Chapter Gwangju Chapter Gyeongnam Chapter Ulsan Chapter Jeonbuk Chapter
32
Installation sites Overseas
Siriraj Hospital
Shanxi Provincial People's Hospital Suzhou Municipal Hospital
Pakchong nana Hospital
China
Thailand
Tianjin Chest Hospital
5. GNT System Details
33
6. Contact us
Head office
Address
3ba 610 Sihwa-gongdan,
Jeongwang-dong, Siheung-si,
Gyeonggi-do, South Korea
Corporate
Phone: +82 (0)31 434 6570
FAX: +82 (0)31 434 6571
Email: [email protected]
Sales inquires
Phone: +82 (0)2 6919 0311
FAX: +82 (0)2 6919 0300
Email: [email protected]
34
6. Contact us
The Invention House (R&D centre)
Address
A1902 Daesung D-Polis,
543-1 Gasan-dong, Geumcheon-gu,
Seoul, South Korea
Phone: +82 (0)2 6919 0301
FAX: +82 (0)2 6919 0300
Email: [email protected]
Sales inquires
Phone: +82 (0)2 6919 0311
FAX: +82 (0)2 6919 0300
Email: [email protected]
35
[GNT System Introduction]
2 0 1 4 0 1 1 6 _ E N E R G I U M . C O . L T D
Ver.3.1