Download pdf - GE D20RIO Brochure

Transcript
  • g Energy

    KEY BENEFITS

    ReducedcopperwiringbetweenI/OmodulesandsubstationcontrollersbyaddingI/OnearthemonitoreddeviceandcommunicatingtotheMultilinD400overthesubstationLAN

    EasyinstallationofthesmallformfactorD.20RIOintoexistingcontrolpanels

    CosteffectivedeploymentofnewandretrofitsubstationautomationprojectsthroughcompatibilityofMultilinD400SubstationGatewaysandMultilinD20Input/Outputperipheralmodules

    TheMultilinD.20RIODistributedI/OControllerisastand-alone,smallformfactordevicedesignedtoprovidedistributed

    I/OcapabilitiesforeasyconnectiontotheMultilinD400substationautomationgatewaythroughthesubstationLAN.The

    D.20RIOprovidesaninterfacetoGEsMultilinD20SeriesofI/Omodulesforacosteffectiveupgradesolution.

    TheD20moduleinterfaceenablesuserstomaintainandleverageexistingengineeringdesigns,processesandautomationinfrastructure

    SimplifyimplementationofdistributedsubstationautomationarchitecturesbyinstallingI/OwhereitsneededandreducingcopperwiringbetweenI/Oandsubstationcontroller

    Ease of Use

    Nospecialconfigurationtoolsarerequired,thedeviceisconnectedviaEthernetusingastandardwebbrowser

    TheMultilinD400automaticallydetectstheD.20RIOandestablishescommunicationswiththeD20modules

    IntuitiveuserinterfaceintegratestheD20I/Omoduleswithinminutes

    Compatiblewithv3.XseriesoftheD20I/OPCommoncode

    NoSubstationLAN?Noproblem.ConnecttheD.20RIOtothebuiltinD400Ethernetswitch

    Hardware

    Productsuppliedwithaccessoriesformultiplemountingoptions(19rack,DINRail,panelmount)

    SupportfordualD.20communicationlinks

    JumperconfigurableoptionforinternalorexternalwettingofD20peripherals

    FEATURES

    APPLICATIONS

    DistributedI/OController

    MultilinD.20 RIO

  • 2 GEDigitalEnergy.com

    D.20RTUUpgradeProcess

    TRADITIONAL AGING RTU UPGRADE SOLUTION GE D400 + D.20 RIO UPGRADE SOLUTION

    INSTALLATION COST

    Modify field wiring Yes Notrequired

    Modify engineering drawings Yes Notrequired

    Building expansion Mayberequired Notrequired

    Marshaling panels Mayberequired Notrequired

    Outages Yes Minimal

    ADVANCED FUNCTIONALITY

    Advanced automation

    Cyber security features

    Optimized configuration methods

    Non-operational data management tools

    Fullreplacement

    RetainI/Oinfrastructure

    Replacecentralcontrolleronly

    Minimizeupgradecost

    Migratetomoderntechnologies

    RemoteI/OWhereYouNeedItThe Multilin D.20 RIO Distributed I/O Controller is a small formfactorstand-alonedevicethatsupportstwoD.20linkchannelsforcommunicationwiththeD20seriesofinput/outputmodules.

    InterfacewithstandardD20I/O(status,analoginput,controlandcombinationinput)peripheralmodules

    Supportforupto30I/OmodulesinasingleD.20RIO,ordistributedoveruptofourD.20RIOdeviceswithinthesubstation

    Smallformfactorwithmultiplemountingoptionsforinstallationflexibility:19Rack,panelmountorDINRail

    UsetheMultilinD.20RIOmoduletoinstallinput/outputmodulesin the substationLAN.No substationLAN?Noproblem, connecttheoptionalD.20RIOdevicedirectlytothebuilt-inD400Ethernetswitch.

    CostEffectiveD20RTUUpgradeSolutionUtilitieshavelargeinvestmentsinhardwiredautomationsystems.Likeeverythingelse,this industrialequipmenthasalifecyclethatmovesfrominfancytonormaloperation,andeventuallytothewearoutstages.Asapieceofequipmentagesitfailsmorefrequently,takeslongertorepair,andeventuallyreachestheendofitslife.

    Re-designandforkliftreplacementsrequireutilitiestore-engineersubstationdesigns,replacefieldwiring,andre-trainstafftomanageandmaintainthesystem,whichisacostlyendeavor.

    The Multilin D.20 RIO option with support for D.20communications provides a cost effective alternative toupgrades of legacy D20 RTUs. Simply replace the failed orend of life Multilin D20 unit with a Multilin D400 Gateway andD.20 RIO module, plug the D.20 interface cable into the D.20

    RIO,connect theD.20RIOtotheD400oranEthernetport in thesubstationLANandyouarereadytoaddmodernfunctionalitytotheMultilinD400seriesofSubstationGatewaysincluding:

    CybersecurityfeaturesforintegrationintoNERCCIPenvironments

    Securerealtimebrowseraccess

    Browser-basedHMIinterface

    Secureremoteengineeringaccess

    IEC61850capabilities

    Automaticrecordretrieval(faultrecords,SOE,settingsfiles,anyotherfileavailableintheIED)

  • 3GEDigitalEnergy.com

    After D400+D.20 RIO Distributed I/O

    Wiring from field devices to D20 I/O module in local junction box

    Substation LAN communications, limited wiring

    Wiring limited to few communication connections

    Individual copper wiring from field devices to control room

    Centralized I/O architecture

    Before Typical Hard Wired I/O

    Wiring to field devices

    Yard Equipment Field Wiring Control Room

    TechnicalSpecifications

    COMMUNICATIONS

    DualEthernet10/100BaseTchannels

    2xD.20linkchannels

    POWER INPUT

    22-55VDC(10%)

    PowersupplyP/N580-3483:Input100-240VAC(10%)110-290VDC(20%)Output24VDC(18-29.5VDC)@2.6Aat70C

    PowersupplyP/N580-3484:Input85-264VAC90-350VDCOutput48VDC(30-56VDC)@3.75Aat70C

    DIMENSIONS

    220Wx146Dx43.5H(mm)

    8.66Wx5.75Dx1.71H(inches)

    MOUNTING OPTIONS

    Suppliedwithrequiredaccessoriesfor:19rackmount,54.5mmDINRailorpanelmount

    ENVIRONMENTAL

    Indooruseonly

    -40Cto70C,5to95%RH

    RELIABILITY

    158,000hoursMTBFat40CperMIL-217F

    CONFIGURATION SOFTWARE

    Built-inwebbrowserbasedgraphicaluserinterface

    OTHER

    Uptofour(4)MultilinD.20RIOunitsperD400unit

    MaximumnumberofD20I/OmodulesperD.20RIO:upto30

    PoweredfromD.20RIO:5D20I/Omodules.Forsystemswithmorethan5I/Omodules,externalpowersupplyisrequired.

    I/OWhereYouNeedIt,MinimizingWiringCosts

    2

    3

    1 1

    321

  • g imagination at work

    Ordering

    DPDA000029: MultilinD.20RIOwith100-240VAC/110-290VDC,Output24VDCPowerSupply

    DPDA000030: MultilinD.20RIOwith85-264VAC/90-350VDC,Output48VDCPowerSupply

    120524-V1

    GEDigitalEnergy2018PowersFerryRoadAtlanta,GA30339Tel:1-877-605-6777(tollfreeinNorthAmerica)678-844-3777(directnumber)[email protected]

    GEDigitalEnergy.comIECisaregisteredtrademarkoftheInternationalElectrotechnicalCommission.NERCisaregisteredtrademarkoftheAmericanElectricReliabilityCorporation.

    GE,theGEmonogram,MultilinandD.20aretrademarksofGeneralElectricCompany.

    GE Digital Energy reserves the right to make changes to specifications of productsdescribedatanytimewithoutnoticeandwithoutobligationtonotifyanypersonofsuchchanges.

    Copyright2012,GeneralElectricCompany.AllRightsReserved.

    FrontPanel

    UserInterface

    BackPanel

    D.20 Communication Status Power and Device Status

    Ethernet Communications2 x 10/100 BaseT interface for D.20 protocol communication with the D400 Gateway

    D.20 Link:Dual D.20 link channels. Support for redundant peripheral systems

    Multilin D.20 RIO Communication Ports (2)

    Power supply options: Input: 85-264VAC,

    45-65Hz / 90-350 VDC. Output: 24VDC/3.5A

    Input: 85-264VAC, 45-65Hz / 90-350 VDC. Output: 48VDC/5A

    LAN Communication Status