Nokia Siemens Networks GSM/EDGE BSS, rel. RG20(BSS), operating documentation, issue 02
ETS2
DN0592447
Issue 1-2
Confidential
2 DN0592447Issue 1-2
ETS2
Id:0900d805807e4914Confidential
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010. All rights reserved
f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
DN0592447Issue 1-2
3
ETS2
Id:0900d805807e4914Confidential
Table of contentsThis document has 22 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1 ETS2 overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 Capacity and performance of ETS2. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 Structure of ETS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113.1 Mechanical structure of ETS2 plug-in unit . . . . . . . . . . . . . . . . . . . . . . . 113.2 Logical structure of ETS2 plug-in unit . . . . . . . . . . . . . . . . . . . . . . . . . . 113.3 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123.3.1 External interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123.3.2 Intra interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4 Operation of ETS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 Power consumption of ETS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6 ETS2 C109474 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7 Connector maps of ETS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197.1 Front panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197.2 Backplane connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4 DN0592447Issue 1-2
ETS2
Id:0900d805807e4914Confidential
List of figuresFigure 1 The operating environment of the ETS2 in transmission protection case. 9Figure 2 The operating environment of the ETS2 in equipment protection case . . 9Figure 3 Block diagram of the ETS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Figure 4 Interfaces of the ETS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Figure 5 Front panel of the ETS2 plug-in unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 6 Jumpers and micro switches of the ETS2. . . . . . . . . . . . . . . . . . . . . . . . 17Figure 7 Optical LC connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DN0592447Issue 1-2
5
ETS2
Id:0900d805807e4914Confidential
List of tablesTable 1 Jumper W3 settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Table 2 Interchangeability code (ICC) settings (SW1). . . . . . . . . . . . . . . . . . . . 17Table 3 Configuration settings (SW2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Table 4 Signals of connector J1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 5 Signals of connector J2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 6 Signals of connector J4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 7 Meanings of the backplane connector signals. . . . . . . . . . . . . . . . . . . . 21
6 DN0592447Issue 1-2
ETS2
Id:0900d805807e4914Confidential
DN0592447Issue 1-2
7
ETS2 Summary of changes
Id:0900d805807e4930Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document issue contains all changes made to previous issues.
Changes made between issue 1-2 and 1-1Table 3 in chapter ETS2 C109474 has been updated.
Changes made between issue 1-1 and 1-0The document has been restructured. Unit Computer, STM-1/OC-3 Optical Interface, Mapper Block, Tributary Rearrangement Block, Serial Broadband Interface, Synchroni-zation Transmission Block, Switch over logic, HDLC Block, Ethernet PHY Block, Timing and Power related information has been removed from chapter Structure of ETS2. Sections Operating principles and Internal interfaces removed from chapter Structure of ETS2. Minor editorial corrections done.
Issue 1-0This is the first issue of ETS2.
8 DN0592447Issue 1-2
ETS2
Id:0900d8058048694cConfidential
ETS2 overview
1 ETS2 overviewThis document describes the ETS2 exchange terminal plug-in unit.
Purpose of ETS2 unitThe ETS2 is an exchange terminal unit. It has two STM-1/OC-3 optical interfaces and is responsible for framing, mapping and multiplexing of two times sixty-three 2.048 Mbit/s or two times eighty-four 1.544 Mbit/s tributaries into SDH STM-1 frame and vice versa. In SONET OC-3 mode ETS2 is responsible for framing, mapping and multiplexing of two times eighty-four 1.544 Mbit/s tributaries into SONET STS-3 frame and vice versa. The ETS2 can be installed in dedicated GT4C-A and GT6C-A cartridges.
The ETS2 provides the following:
• two duplicated STM-1/OC-3 optical interfaces • two duplicated Serial Broadband Interfaces (SBI) with a bit rate of 655 Mbit/s each
connected to the GSW2KB • 8 Mbit/s TDM lines for HDLC/LAPD • two IEEE 802.3/Ethernet interfaces with bit rate of 10/100 Mbps that can be used to
handle same functions as the HDLC/LAPD link.
Operating environment of ETS2 unitThe ETS2 plug-in unit is connected to two external STM-1/OC-3 optical interfaces. The unit is connected to the switching network with two redundant SBI interfaces. The main-tenance of ETS2 is handled with an LAPD link, which is connected by the separate 8 Mbit/s TDM-lines or 100 Mbps Ethernet interfaces.
Operating voltages required by the units are formed with an on board integrated power unit from an external -48 V voltage.
The following figures display the operating environments of the ETS2 plug-in unit.
DN0592447Issue 1-2
9
ETS2 ETS2 overview
Id:0900d8058048694cConfidential
Figure 1 The operating environment of the ETS2 in transmission protection case
Figure 2 The operating environment of the ETS2 in equipment protection case
ETS2
GSW1
GSW8K or
GSW2KB
2xHotlink
MSP1+1 protectedSTM-1/OC-3 line
(cable protection)
GSW0
GSW8K orGSW2KB
working
working
protecting
protecting
2xHotlink
BSC: BSCUMSC: BSU, CCSU
8Mbit/s tdm for LAPD
DN05158947
ETS2
ETS2
GSW0
GSW1
GSW8K orGSW2KB
STM-1/OC-3lines
GSW8K orGSW2KB
MSP 1+1 equipment protection
BSC: BSCUMSC: BSU, CCSU
8 Mbit/s tdmfor LAPD
STM-1/OC-3lines
working
protecting
working
protecting
spare
2
2
2
2
Message channelbetween duplicated
units
DN05158959
working
10 DN0592447Issue 1-2
ETS2
Id:0900d80580486c13Confidential
Capacity and performance of ETS2
2 Capacity and performance of ETS2The capacity of the ETS2 is two SDH STM-1/Sonet OC-3 interfaces with bit rate of 155,52 Mbit/s each. They have been duplicated for redundancy. The optical interfaces are provided by hot-pluggable SFP modules, which are not part of the structure of the ETS2 plug-in unit.
The ETS2 has
• MPC8280 PowerQUICC II HIP7 processor • 128 MByte SDRAM main memory at 100 MHz • 8 MByte Boot Flash
• two duplicated SBI interfaces with a bit rate or 655 Mbit/s each • two duplicated 8 Mbit/s TDM lines, from which 8x or 16x64 kbit/s used for single
unit's HDLC/LAPD link • two IEEE 802.3/Ethernet interfaces with bit rate of 10/100 Mbps.
DN0592447Issue 1-2
11
ETS2 Structure of ETS2
Id:0900d805804780d2Confidential
3 Structure of ETS2
3.1 Mechanical structure of ETS2 plug-in unitETS2 plug-in unitThe ETS2 plug-in units consist of a single printed wiring board (PWB). The dimensions of the PWB are 233.35 x 222.3 mm. The thickness of the PWB is 1.6 mm and spacing in the cartridge is 4T (20.32 mm). There are eight SFP connectors in the front panel of the plug-in unit. There are also three leds on the front panel: one bicolour and two single-colour leds.
The unit connects to the backplane with 5-row Hard Metric Z-pack female connectors. The connectors are two AB-type female connectors (J1 and J4) and a 22-pin B-type female connector (J2).
3.2 Logical structure of ETS2 plug-in unitThe following block diagram of the ETS2 plug-in unit illustrates the logical structure (including possible loop interfaces).
Figure 3 Block diagram of the ETS2
UNITCOMPUTER
TRRFPGA
TributaryRearrangement
Block
SBIInterface
MapperBlock
STM-1/OC-3
OpticalInterface
ETH PHYs
CartridgeInformation
SET_(4:0)Side selection
Wired alarmControl TDM
Interface
SynchronizationTransmission
DC/DCconverter
Switch overlogic
60
xb
usSTM-1/OC-3
Interfaces
0 M
0 R
1 M
1 R
-48V
Ethernet 0
Ethernet 1
ServiceTerminal
SBIInterfaces
SB1-0
SB1-1
SB2-0
SB2-1
CHI bus
TO
AC
Contr
ol&
Superv
isio
n
2N Interface
Me
ssa
ge
Ch
an
ne
l
Pro
tection
Inte
rfa
ce
TCL 0TCL 1
2N bus
ControlTDMs
0 00 11 01 1
LA
PD
+C
on
tro
l
LA
PD
Data +Control
Data +Control
Pro
tectio
nIn
terf
ace
Co
ntr
ol
Timing 8k, 8M
Co
ntr
ol
Control &Supervision
Control
Status info
Data +Control
Data +Control
DN05158986
CSto/from2N unit
12 DN0592447Issue 1-2
ETS2
Id:0900d805804780d2Confidential
Structure of ETS2
3.3 Interfaces
Figure 4 Interfaces of the ETS2
3.3.1 External interfaces
STM-1/OC-3 InterfaceThe ETS2 has two redundant optical STM-1/OC-3 interfaces on the front panel (total of four interfaces), which are implemented using SFP transceivers. The SFP transceivers are not part of the structure of the ETS2 plug-in unit.
3.3.2 Intra interfaces
Serial Broadband InterfaceTwo 2N redundant SBI interfaces (total of four SFP connectors) are located on front plane. The SBI interface is used for connecting STM-1/OC-3 traffic of ETS2 plug-in unit to group switch.
Serial Control Bus InterfaceFour internal TDM lines are connected to the backplane. Two of these TDMs are con-nected to active GSW and two are connected to redundant GSW.
Ethernet InterfaceThere are two 10/100 Mbps Ethernet interfaces in the plug-in unit. The Ethernet inter-faces are accessible through a backplane.
655 Mbit/s
Serial BroadbandInterface
ETS2
STM-1/OC-3
lines
10/100 eth.Master
Redundant-48V UB
B0V
D0V
8k, 8M
TCL
CGS
2
2N Connection
TAL, ALTST
CR, CT
SLOT_ID, LOC_ID
Master
Redundant
8
Front panel interfaces Backplane interfaces
SET_(4:0)
RS-232
JTAG + Test
DN05158962
2
DN0592447Issue 1-2
13
ETS2 Structure of ETS2
Id:0900d805804780d2Confidential
Alarm InterfaceThere are a total of four signals reserved for wired alarms in the backplane, but only one of them is used on ETS2. This wired alarm is connected directly to the TRR FPGA. If alarm is activated, the wired alarm is set.
14 DN0592447Issue 1-2
ETS2
Id:0900d80580479c54Confidential
Operation of ETS2
4 Operation of ETS2Front panel of ETS2 plug-in unit
Figure 5 Front panel of the ETS2 plug-in unit
LED indicatorThe front panel of the ETS2 plug-in units has one bicolour (red and orange) alarm LED indicator and two single-colour (one red, one green) LED indicators.
The green LED (OPR) is lit when at least one of the unit's STM-1/OC-3 interfaces is active.
The following functions are defined for the red LED (ALARM):
1. If the incoming synchronization signals of the unit are faulty2. If power failure occurs
The bicolour LED (Tx/Rx FAIL) indicates errors in STM-1 / OC-3 interfaces. The follow-ing functions are defined for it:
1. If there are no alarms or errors, the LED is off.2. If there are errors in TX direction, the LED is on (red colour)
DN05158974
OPR
SB1-0
SB1-1
SB2-0
SB2-1
Tx/Rx FAIL
STM-1/OC-3 i/f #0 Master
STM-1/OC-3 i/f #0 Redundant
STM-1/OC-3 i/f #1 Master
STM-1/OC-3 i/f #1 Redundant
ALARM
CLASS 1LASER
PRODUCTIEC/EN60825-1
DN0592447Issue 1-2
15
ETS2 Operation of ETS2
Id:0900d80580479c54Confidential
3. If there are errors in RX directions, the LEDis on (orange colour)
Front panel connectorsOn the ETS2, there are four LC/SFP-type fiber connectors for STM-1/OC-3 interfaces and four SFP-type connectors for SBI interfaces. For detailed information, see Connec-tor maps of ETS2.
Backplane connectorsThe ETS2 plug-in unit is connected to the backplane with three 5-row Hard Metric Z-pack female connectors (J4, J2 and J1). For connector map, see Connector maps of ETS2.
16 DN0592447Issue 1-2
ETS2
Id:0900d8058047ce19Confidential
Power consumption of ETS2
5 Power consumption of ETS2The estimated typical power consumption for the ETS2 plug-in unit is approximately 26 W. The estimated maximum power consumption for the ETS2 plug-in unit is 29 W.
DN0592447Issue 1-2
17
ETS2 ETS2 C109474
Id:0900d805807e48ebConfidential
6 ETS2 C109474
Figure 6 Jumpers and micro switches of the ETS2
Jumper W3 settingsThe setting of the Jumper W3 is presented in the table below (W3). This jumper is not set during normal operation.
Interchangeability settings SW1The setting of the interchangeability code is presented in the table below (SW1).
J2
J4
J1
DN05158998
W3
SW2
OFF ON
SW1
SW1, SW2
W3
1234
8765
321
456
Pins When not connected/when connected
1 6 External watchdog enabled / External watchdog disabled
2 5 Backplane connector JTAG selected / Emulator connector W4 JTAG selected
3 4 RSTCONF signal pulled low / RSTCONF signal connected to Vcc
Table 1 Jumper W3 settings.
ICC code Setting
4–5 3-6 2-7 1-8
A OFF OFF OFF OFF
Table 2 Interchangeability code (ICC) settings (SW1).
18 DN0592447Issue 1-2
ETS2
Id:0900d805807e48ebConfidential
ETS2 C109474
Unit configuration settingsThe unit configuration settings are presented in the table below (SW2).
B OFF OFF OFF ON
C OFF OFF ON OFF
D OFF OFF ON ON
E OFF ON OFF OFF
F OFF ON OFF ON
G OFF ON ON OFF
H OFF ON ON ON
J ON OFF OFF OFF
K ON OFF OFF ON
L ON OFF ON OFF
M ON OFF ON ON
N ON ON OFF OFF
P ON ON OFF ON
R ON ON ON OFF
Switch Default setting Function
1-8 OFF Width of the HDLC link:
OFF = 16x64 kbit/s, ON = 8x64 kbit/s
2-7 OFF Reserved for future use
3-6 OFF 1F#0 ETP mode:
OFF = normal mode, ON = ETP mode
4-5 OFF 1F#1 ETP mode:
OFF = normal mode, ON = ETP mode
Table 3 Configuration settings (SW2).
ICC code Setting
Table 2 Interchangeability code (ICC) settings (SW1). (Cont.)
DN0592447Issue 1-2
19
ETS2 Connector maps of ETS2
Id:0900d80580482554Confidential
7 Connector maps of ETS2
7.1 Front panel connectorsThe ETS2 plug-in unit has four LC/SFP-type fiber connectors for STM-1/OC-3 interfaces and four SFP-type connectors for SBI interfaces.
Figure 7 Optical LC connectors
7.2 Backplane connectorsThe backplane connector signals are presented in the tables below.
TX
RX
DN05159888
E D C B A
1 R_2N0_B R_2N0_A T_2N0_B T_2N0_A
2 R_2N1_B R_2N1_A T_2N1_B T_2N1_A
3 R_2N PQ B R_2N PQ A T_2N PQ B T_2N PQ A
4 CS0_B CS1_B CS0_A CS1_A
5 R_2N TCL 0 B R_2N TCL 0 A T_2N TCL 0 B T_2N TCL 0 A
6 R_2N TCL 1 B R_2N TCL 1 A T_2N TCL 1 B T_2N TCL 1 A
7 RESERVED RESERVED RESERVED RESERVED
8 RESERVED RESERVED RESERVED RESERVED
9
10
11
12
13
14
15 TXD GND GND RXD
16
17 RCTP1W RCTP0W TCTP1W TCTP0W
18 RCTP1P RCTP0P TCTP1P TCTP0P
19 TCK1 TMS1 TDI1 TDO1 _TRST1
20 GND GND USER1 USER0 AW1
Table 4 Signals of connector J1
20 DN0592447Issue 1-2
ETS2
Id:0900d80580482554Confidential
Connector maps of ETS2
21 TCK2 TMS2 TDI2 TDO2 _TRST2
22 GND GND GND GND _JTAGEN
23 SCLK3 SMODE3 SDI3 SDO3 3V3
24 GND GND GND GND _ISPEN3
25 FLASH_RY_ BY
Table 4 Signals of connector J1 (Cont.)
E D C B A
1
2
3 ALTST AL1
4 8M B 8M A 8k B 8k A
5 CS0_A
6 CS0_B
7 CS1_A
8 CS1_B
9 SET_4 SET_3 SET_2 SET_1 SET_0
10 CGS B CGS A
11
12
13 CR 00 B CR 00 A CT 00 B CT 00 A
14 CR 01 B CR 01 A CT 01 B CT 01 A
15 CR 10 B CR 10 A CT 10 B CT 10 A
16 CR 11 B CR 11 A CT 11 B CT 11 A
17 3V3_OUT
18 SLOT_ID4 SLOT_ID3 SLOT_ID2 SLOT_ID1 SLOT_ID0
19 LOC_ID3 LOC_ID2 LOC_ID1 LOC_ID0
20 LOC_ID7 LOC_ID6 LOC_ID5 LOC_ID4
21 LOC_ID10 LOC_ID9 LOC_ID8
22
Table 5 Signals of connector J2
E D C B A
1
2
3
Table 6 Signals of connector J4
DN0592447Issue 1-2
21
ETS2 Connector maps of ETS2
Id:0900d80580482554Confidential
The table below presents the meanings of the backplane connectors.
4
5
6
7
8
9
10
11
12 -UB 0 -UB 0 B0V 0 B0V 0
13 -UB 0 -UB 0 B0V 0 B0V 0
14
15 ETH0: MDI[3]- ETH0: MDI[3]+ GND ETH0: MDI[2]- ETH0: MDI[2]+
16 ETH0: MDI[1]- ETH0: MDI[1]+ GND ETH0: MDI[0]- ETH0: MDI[0]+
17 ETH1: MDI[3]- ETH1: MDI[3]+ GND ETH1: MDI[2]- ETH1: MDI[2]+
18 ETH1: MDI[1]- ETH1: MDI[1]+ GND ETH1: MDI[0]- ETH1: MDI[0]+
19 TCL 0 B TCL 0 A
20
21 TCL 1 B TCL 1 A
22
23
24
25
Table 6 Signals of connector J4 (Cont.)
Pin Meaning
CR00x...CR11x Differential, Receive Control TDM line signal
CT00x…CT11x Differential, Transmit Control TDM line signal
8M x Differential, 8 MHz basic timing signal
8k x Differential, 8 kHZ basic timing signal
CGS x Differential, GSW's changeover signal
AL1 Wired alarm
TCL0A, TCL0B Synchronizing signal of the synchronization unit.
-UB -48 VDC battery voltage supply
B0V 0V reference for -48 V
TCL 0 x, TCL 1 x Synchronization signals to the clock system
ETH0: x, ETH1: x Ethernet interface signals
Table 7 Meanings of the backplane connector signals.
22 DN0592447Issue 1-2
ETS2
Id:0900d80580482554Confidential
Connector maps of ETS2
R_2N0_x, R_2N1_x Differential, Receive signal of physical layer protection for interfaces 0 and 1
T_2N0_x, T_2N1_x Differential, Transmit signal of physical layer protection for interfaces 0 and 1
R_2N PQ x, T_2N PQ x Differential, Receive and transmit signals of message channel between Unit Computers
R_2N TCL 0 x, R_2N TCL 1 x
Differential, Receive signal of TCL synch between 2N unit for interfaces 0 and 1
T_2N TCL 0 x, T_2N TCL 1 x
Differential, Transmit signal of TCL synch between 2N unit for inter-faces 0 and 1
CS0_x, CS1_x Differential, switch over logic signals for 2N units
SET_x Wired settings from cartridge
SLOT_IDx Slot identification information from cartridge
LOC_IDx Location information from cartridge
TXD, RXD Service terminal RS-232 signals
3V3_OUT +3.3 V output from unit to cartridge Connected to +3.3 V through a resistor of 100Ω and a diode.
RCTP0x, RCTP1x, TCTP0x, TCTP1x
Transmit and receive clock test points for STM-1/OC-3 lines
RESERVED Reserved for possible future needs of 2N connection
TCKx, TMSx, TDIx, TDOx, _TRSTx, USERx, AW1, _JTAGEN, SCLK3, SMODE3, SDI3, SDO3, 3V3, ISPEN3, FLASH_RY_BY
JTAG and ISP interface signals
Pin Meaning
Table 7 Meanings of the backplane connector signals. (Cont.)