Outline
• DO Rev B tests– Max Occupied Bandwidth Test (BC 3,6)– Correction to transmitter spurious emission limits
• SVDO MPS– Demodulation of Forward Traffic Channel in
AWGN– Receiver Sensitivity and Dynamic Range– Single Tone Desensitization– Waveform Quality and Frequency Accuracy– Maximum RF Output Power– Conducted Spurious Emissions– Max Occupied Bandwidth
04/21/23QUALCOMM Confidential and Proprietary2
DO REV B
04/21/23 QUALCOMM Confidential and Proprietary 3
Max Occupied Bandwidth Test
The existing test is defined for single-carrier operation only. The test is extended to include multi-carrier operation In multi-carrier operation, the occupied
bandwidth is defined as the frequency range, whereby the power of emissions averaged over the frequency above the edge frequency of the rightmost carrier and under the edge frequency of the leftmost carrier are 0.5% each of the total radiation power of all modulated carriers.
The test ensures that the occupied bandwidth does not exceed limits specified for adjacent carriers as well as a carrier pair at maximum separation
04/21/23QUALCOMM Confidential and Proprietary4
Max Occupied Bandwidth
04/21/23 QUALCOMM Confidential and Proprietary 5
Maximum Frequency Separation
0 5.0 f, MHz
Upper Edge Frequency
Lower Edge Frequency
f, MHz
1 2 3
0 1.25 2.50
Upper Edge Frequency
Lower Edge Frequency
Minimum Standard
04/21/23 QUALCOMM Proprietary
In the multiple carrier transmission, the occupied bandwidth for each carrier still remains within 1.48 MHz. Based on this assumption, the following minimum standards are defined.
For the test with two reverse CDMA channels at maximum frequency separation, the occupied bandwidth shall not exceed MaxReverseLinkBandwidth × 0.0025 + 1.48MHz. For the test with two or more adjacent reverse CDMA channels, the occupied bandwidth shall not exceed (N-1) × M + 1.48 MHz where N is the number of reverse CDMA channels and M is the minimum carrier spacing used in a Band Class.
Correction to transmitter spurious emission limits
The existing transmitter spurious emission limits for Test 2 in multi-carrier transmission (Table 4.4.1.3-8 of C.S0033-B) has overlooked ITU Category B limit. This is inconsistent with Test 1 (Table 4.4.1.3-2) and Test 3 (Table 4.4.1.3-9).
We propose to amend Table 4.4.1.3-8 to include ITU Category B limit. For Test 2, ITU Category B limit is intended to apply only to Band Classes 6 and 8.
04/21/23QUALCOMM Confidential and Proprietary7
Correction to transmitter spurious emission limits (cont.)
04/21/23 QUALCOMM Confidential and Proprietary 8
For |f| Within the Range Emission Limit1.25 MHz to 2.25 MHz 6 dBm / 1 MHz
2.25 MHz to 3.5×Ns MHz -13 dBm / 1 MHz
> 3.5×Ns MHz (ITU Category B)
-36 dBm / 1 kHz; 9 kHz < f < 150 kHz
-36 dBm / 10 kHz; 150 kHz < f < 30 MHz
-36 dBm / 100 KHz; 30 MHz < f < 1 GHz
-30 dBm / 1 MHz; 1 GHz < f < 12.75 GHzNote: All frequencies in the measurement bandwidth shall satisfy the restrictions on |f| where f where f is measured as the frequency offset from the center frequency of each channel.
Except for ITU Category B, emission Limits shall apply between the carriers when MaxReverseLinkBandwidth ×0.0025 ≥ 41.25 MHz.
Ns = MaxReverseLinkBandwidth×0.0025
ITU Category B limit is intended to apply only to Band Classes 6 and 8.
For |f| Within the Range Emission Limit1.25 MHz to 2.25 MHz 6 dBm / 1 MHz> 2.25 MHz -13 dBm / 1 MHzNote: All frequencies in the measurement bandwidth shall satisfy the restrictions on |f| where f where f is measured as the frequency offset from the center frequency of each channel.
Emission Limits shall apply between the carriers when MaxReverseLinkBandwidth 41.25 MHz.
Table 4.4.1.3‑8 Old
Table 4.4.1.3‑8 New
SVDO
04/21/23 QUALCOMM Confidential and Proprietary 9
SVDO MPS
An MPS for Simultaneous 1x + DO operationSVDO-capable mobiles shall pass these tests
“in addition to” existing 1x and DO MPS testsTests are similar to DO RevB multi-carrierTests:
Demodulation of Forward Traffic Channel in AWGN Receiver Sensitivity and Dynamic Range Single Tone Desensitization Waveform Quality and Frequency Accuracy Maximum RF Output Power Conducted Spurious Emissions Max Occupied Bandwidth
04/21/23QUALCOMM Confidential and Proprietary10
Demodulation of Forward Traffic Channel in AWGN
• Test Scenario– Test carriers at max separation
• 1x+1DO configuration
– Using TAP, set up 1x and DO calls at specified rates
• MPS– DO: same as DO-revB– 1x: same as 1x
04/21/23QUALCOMM Confidential and Proprietary
Receiver Sensitivity Test
• Test Scenario– 1x + 1DO scenario with 1x and DO carriers at max
separation– Using TAP, set up 1x and DO calls at specified rates– Ior
• DO: -105.5 dBm• 1x: -104 dBm
• MPS– DO: same as DO-revB– 1x: same as 1x
04/21/23QUALCOMM Confidential and Proprietary
Dynamic Range Test
• Test Scenario– Set the max number of 1x and DO carriers
• Ior: -25 dBm for all carriers
– Using TAP, set up 1x and DO calls at specified rates– MPS
• DO: same as DO-revB• 1x: same as 1x
04/21/23QUALCOMM Confidential and Proprietary
Single Tone Desensitization• Test Scenario
– 1x+ 1DO configuration– Maximum separation between 1x and DO carriers– Using TAP, set up 1x and DO calls at specified rates– Ior
• DO: same as DO-revB• 1x: 3 dB relaxed from the existing 1x spec
– Tone Position: same as DO-revB– Tone Power: -50 dBm
• MPS– DO: same as DO-revB– 1x: same as 1x
04/21/23QUALCOMM Confidential and Proprietary
Waveform Quality and Frequency Accuracy
Test Scenario 1x + 1DO Closest separation – 1.23 Mhz(CELL band), 1.25 Mhz (PCS
band) Using TAP, set up 1x and DO calls at specified rates 1x and DO Ior such that equal power can be maintained
among 1x and DO carriersMPS
Same as DO-revB, where each carrier showsRho > 0.933|Time Error| < 1 usec|Freq Error| < 300 Hz (CELL band), 150 Hz (PCS band)
04/21/23QUALCOMM Confidential and Proprietary
Conducted Spurious EmissionsTest Scenario
1x + 1DOMax separation between the 1x and DO carriersEqual power on 1x and DO carriersMPS
– Same as DO-revB 1x + 2DO
Min separation between 1x and DO carriers– 1.23 Mhz(CELL band), 1.25 Mhz(PCS band)
Equal power on all 1x and DO carriersMPS
– Same as DO-revB for 3 carriers
04/21/23QUALCOMM Confidential and Proprietary
Maximum RF Output Power
• Test Scenario– Same scenario and procedure as emissions test
case for 1x + 2DO
• MPS– The maximum output power should be within the
limits in Table 4.3.4.3-1 less the power back-off of 3.3 dB
04/21/23QUALCOMM Confidential and Proprietary
Occupied Bandwidth Test
• Test cases and MPS similar to DO-revB• Test procedure similar to the SVDO emissions
test