Pumps and Systems forBuilding Engineering/Building Services,Domestic, Municipal andIndustrial Water Supply
Catalogue Water Supply
Borehole Pumps 3" to 24"
Catalogue B2 - 50 Hz - 2009 B2
7
1
2
3
5
4
6
8
9
10
13
12
11
Wilo-Jet WJ
B1
1
Wilo-Sub TWI 5-SE P & P
B1
2
Wilo-SilentMaster
B1
3
Wilo-Sub TWU 3
B1
4
Wilo-RainSystemAF Comfort
B1
5
Wilo-Comfort-Vario COR
B4
6
Wilo-Comfort-Vario CO 1/MVIE
B4
6
Wilo-StratosECO
A1
7
Wilo-Safe
A1
8
Wilo-Star-Z 15 TT
A1
9
Wilo-DrainLift Con
C3
10
Wilo-Stratos
A1
11
Wilo-Drain TM/TMW 32 Twister
C1
12
Wilo-DrainLift S
C3
13
Series Catalogue
7
1
2 3
5
4
6
89
10
12 11
Wilo-EMU KM
B2
1
Wilo-ASP
A3
2
Wilo-VeroNorm-NPG
A3
3
Wilo-ComfortCOR-6 MVI/CC
B4
Wilo-EMUPORT
on request
5
Wilo-DrainLift WS
C3
6
Wilo-VeroNorm-NPG
A3
3
Wilo-EMUFA 08.52
C2
7
Wilo-EMUMegaprop TR 325
C4
8
Wilo-EMU RZP
C4
9
Wilo-EMU FA
C2
10
Wilo-EMU KPR
C2
11
Wilo-CC-System
A1-A3, B4
12
Series Catalogue
4
i
Programme overview and fields of applications
BBoreholee pumpss 3"" too 24"
Pumpp type Version Mainn fieldd off application
Self-
prim
ing
Nonn
sel
f-pr
imin
g
Subm
ersi
ble-
mot
orr p
umps
Fixe
dd sp
eed
Spee
d-co
ntro
lled
Waterr supply
Wilo-Sub TWU 3 S S S S S Wilo-Subb TWUU 4 S/M S/M S/M S/M S/M Wilo-Subb TWUU 4-QC S/M S/M S/M S/M S/M
Wilo-Sub TWU 3 Plug & Pump system S S S S SWilo-Sub TWU 4 Plug & Pump system S/M S/M S/M S/M S/M
Irrigationn andd drainage
Wilo-Sub TWU 6-B M/C M/C M/C M/CWilo-Sub TWU 8-B M/C M/C M/C M/C
Potablee waterr supply
Wilo-Sub TWI 4-B S/M S/M S/M S/M S/M Wilo-Subb TWII 6-B M M M M Wilo-Subb TWII 8-B M M M
Municipal// Industry
Wilo-EMU 6 series M/C M/C M/C Wilo-EMUU 8series M/C M/C M/C
Wilo-EMU 10 series and larger C C
Speciall pumps
Wilo-EMUU Polderr pumps M/C M/C M/C
Neww inn thee programmee orr seriess extensionn orr modification
Borehole pumps 3" to 24"
Sing
lepu
mps
Syst
ems
Acce
ssor
ies
Main field of application Key:SMC
-
Page
Borehole pumps 3" to 24"
Pump type Version Main field of application
Self-
prim
ing
Non
sel
f-pr
imin
g
Subm
ersi
ble-
mot
or p
umps
Fixe
d sp
eed
Spee
d-co
ntro
lled
Water supply
Wilo-Sub TWU 4 Wilo-Sub TWU 4-QC
Irrigation and drainage
Potable water supply
Wilo-Sub TWI 6-B Wilo-Sub TWI 8-B
Municipal/ Industry
Wilo-EMU 8series
Special pumps
Wilo-EMU Polder pumps
New in the programme or series extension or modification
ii
Programme overview and fields of applications
BBorehole pumps 3" to 24"
SSing
lepu
mps
Syst
ems
Acce
ssor
ies
MMain field of application Key:S Single- and two-family housesM Multi-family housesC Commercial Applicable- Not applicable
Self-sufficient water supply
Rainwater utilisation(as compact unit withextensible storagetanks)Rainwater utilisation(in conjunction with undergroundstorage tank or rainwaterstorage)Sprinkling
Irrigation
Spraying
Well and rainwater storagewater supplyLowering of ground waterlevelsSwimming-pool watercirculationCooling water circulationsystems
Cold water circulation systems
Pure water circulation systems
Potable water supply
Pressure boosting systems
Fire-extinguishing watersupply
Washing systems
Industrial applications
Boiler feed
Process engineering
Page
S S 34
S/M S/M S/M S/M 39
S/M S/M S/M S/M 54
S S 65
S/M S/M S/M 70
M/C M/C M/C M/C C 76
M/C M/C M/C M/C C 76
S/M C M/C M/C M/C S/C S/C C C C 132
M/C M/C M/C M/C M/C M/C M/C C C C 182
M/C M/C M/C M/C C M/C M/C C C C 208
M/C M/C C C M/C M/C M/C C 238
M/C M/C C C M/C M/C M/C M/C C 284
C C C C C C C C M/C C 396
C C C C C C C C C 475
3
Contents
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Water
supply
Irrigation and drainage
Pota
ble
water
supply
Municipal/in
dustrial app
lications
Special pum
ps
General notes and abbreviations 6
Planning guide 8
Water supply 24
Wilo-Sub TWU 3Wilo-Sub TWU 4Wilo-Sub TWU 4-QCWilo-Sub TWU Plug & Pump systems
Irrigation and drainage 76
Wilo-Sub TWU 6...-B, 8...-B
Potable water supply 110
Wilo-Sub TWI 4-B, 6-B, 8-B
Municipal/industrial applications 234
Wilo-EMU 6"-, 8"-, 10"24" series
Special pumps 472Accessories 495
4 Subject to change 09/2008 WILO SE
Water supplyContents
Water supply
Single pumps / systems Series overview 24
Wilo-Sub TWU 3-01.. 34
Wilo-Sub TWU 4-02..-B/-C 39
Wilo-Sub TWU 4-04..-B 41
Wilo-Sub TWU 4-08..-B 48
Wilo-Sub TWU 4-16..-B 51
Wilo-Sub TWU 4-02..-B/-C-QC 56
Wilo-Sub TWU 4-04..-B-QC 59
Wilo-Sub TWU 4-08..-B-QC 62
Wilo-Sub TWU 3-01.. Plug & Pump 65
Wilo-Sub TWU 4-04.. Plug & Pump 70
Irrigation and drainage
Single pumps Series overview 76
Wilo-Sub TWU 6-12..-B 84
Wilo-Sub TWU 6-18..-B 89
Wilo-Sub TWU 6-24..-B 92
Wilo-Sub TWU 6-35..-B 95
Wilo-Sub TWU 6-45..-B 98
Wilo-Sub TWU 8-42..-B 101
Wilo-Sub TWU 8-80..-B 104
Wilo-Sub TWU 8-100..-B 107
Potable water supply
Single pumps Series overview 110
Wilo-Sub TWI 4..-B Wilo-Sub TWI 4.01..-B (1~230 V, 50 Hz) 134
Wilo-Sub TWI 4.02..-B (1~230 V, 50 Hz) 138
Wilo-Sub TWI 4.03..-B (1~230 V, 50 Hz) 142
Wilo-Sub TWI 4.05..-B (1~230 V, 50 Hz) 170
Wilo-Sub TWI 4.09..-B (1~230 V, 50 Hz) 174
Wilo-Sub TWI 4.14..-B (1~230 V, 50 Hz) 178
Wilo-Sub TWI 4.01..-B (3~400 V, 50 Hz) 158
Wilo-Sub TWI 4.02..-B (3~400 V, 50 Hz) 162
Wilo-Sub TWI 4.03..-B (3~400 V, 50 Hz) 166
Wilo-Sub TWI 4.05..-B (3~400 V, 50 Hz) 170
Wilo-Sub TWI 4.09..-B (3~400 V, 50 Hz) 174
Wilo-Sub TWI 4.14..-B (3~400 V, 50 Hz) 178
Wilo-Sub TWI 6..-B Wilo-Sub TWI 6.18..-B 184
Wilo-Sub TWI 6.30..-B 192
Wilo-Sub TWI 6.50..-B 200
Wilo-Sub TWI 6.60..-B 204
Wilo-Sub TWI 8..-B Wilo-Sub TWI 8.80..-B 210
Wilo-Sub TWI 8.90..-B 222
5
Water supplyContents
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Water
supply
Irrigation and drainage
Secondary ho
t water
sup
ply
Municipal/in
dustrial app
lications
Special pum
ps
Accessories
Municipal/industrial applications
Single pumps Series overview 234
Wilo-EMU 6" series Wilo-EMU NK 62 240
Wilo-EMU NK 63 256
Wilo-EMU NK 64 272
Wilo-EMU 8" series Wilo-EMU NK 80 287
Wilo-EMU NK 80.2 299
Wilo-EMU NK 81 311
Wilo-EMU NK 82 323
Wilo-EMU KD 13 331
Wilo-EMU KD 16 339
Wilo-EMU KD 25 347
Wilo-EMU KD 38 355
Wilo-EMU K 83.1 359
Wilo-EMU K 84 367
Wilo-EMU K 85 375
Wilo-EMU NK 86 379
Wilo-EMU NK 87 387
Wilo-EMU 10"24 series Wilo-EMU K 102 399
Wilo-EMU K 103 407
Wilo-EMU K 104 415
Wilo-EMU K 105 419
Wilo-EMU K 126, Wilo-EMU K 126.1 423
Wilo-EMU SCH 200 427
Wilo-EMU K 127, Wilo-EMU K 127.1 431
Wilo-EMU K 146, Wilo-EMU K 146.1 435
Wilo-EMU KM 13.. 439
Wilo-EMU D 200 443
Wilo-EMU D 500 447
Wilo-EMU K 221 451
Wilo-EMU DCH 980 455
Wilo-EMU D 1800 459
Wilo-EMU KM 3100 463
Wilo-EMU SCH 2350 467
Special pumps
Polder pumps Series overview 472
Wilo-EMU KM 150P 477
Wilo-EMU K 126P 480
Wilo-EMU K 127P 483
Wilo-EMU K 146P 486
Wilo-EMU D 500P 489
Wilo-EMU DCH 980P 492
Accessories
Mechanical accessories 495
Electrical accessories 509
6 Subject to change 09/2008 WILO SE
General notes and abbrevaitions
Abbreviations used and what they mean
Abbreviation Meaning
1~ 1-phase current
3~ 3-phase current
D Direct activation
DM Three-phase motor in direct activation
DN Nominal diameter of the flange connection
EM Single-phase motor with starting capacitor
EMSC Single-phase motor with built-in starting capacitor
GRD/GLRD Mechanical seal
d H Degree of German water hardness; replaced with the SI unit mmol/l; Conversion: 1 dH = 0.1783 mmol/l
H Delivery head
HZ Approved range for sprinkler pumps
IA Starting current
IN Nominal current; current at P2
IW Current consumption for power requirement of the shaft PW
Inst. Installation: H = horizontal, V = vertical
KLF PTC thermistor sensor
KTL-coating Electrophoretic painting (cataphoretic coating): Painting with high adhesive strength for long-lasting corrosion protection
KTW Approval for products with plastics, for use in pota-ble water applications
LB Supply availability (L = warehouse goods, C = availa-ble in 2 weeks, K = available in 4 weeks, A = delivery time on request)
max. Maximum diameter of the unit, incl. cable
mmol/l Millimol per litre; SI-unit for assessing the water hardness (total hardness or concentration of alkaline earth ions)
P1 Power consumption (power supplied from the mains)
PN = P2 Motor rated power
PW Power requirement of the pump hydraulics
PN Pressure class in bar (e. g. PN10 = suitable up to 10 bar)
PTC Positive Temperature Coefficient (also see: KLF)
PT 100 Platinum temperature sensor with a resistance value of 100 at 0 C
Q (= ) Volume flow
QZ Approved range for sprinkler pumps
RV Non-return valve
RVF Non-return valve, spring-mounted
SBM Run signal or collective run signal
V.
Abbreviation Meaning
SD Three-phase motor in star/delta activation
SD-R Three-phase motor in star/delta activation, rewinda-ble
SSM Fault signal or collective fault signal
v Speed
TrinkwV 2001 German Drinking Water Ordinance of 2001(valid from 01.01.2003)
WRAS Water Regulations Advisory Scheme (potable water approval for Great Britain and Northern Ireland)
WSK Thermal winding contacts (in motor for monitoring the winding temperature, full motor protection by additional tripping unit)
Y/ Star/delta activation
Operating mode of double pumps:Individual operation of the relevant operating pump
Operating mode of double pumps:Parallel operation of both pumps
Number of poles of electric motors:2-pole motor = approx. 2900 rpm at 50 Hz
Number of poles of electric motors:4-pole motor = approx. 1450 rpm at 50 Hz
Number of poles of electric motors:6-pole motor = approx. 950 rpm at 50 Hz
7
General notes and abbrevaitions
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Water
supply
Second
ary ho
t water
supply
Irrigation and drainage
Municipal/in
dustrial app
lications
Special pum
ps
Material designations and their meaning Wear and tearPumps or parts of pumps are subject to wear in accordance with state-of-the-art technology (DIN 31051/DIN-EN 13306). This wear may vary depending on operating parameters (temperature, pressure, speed, water condition) and installation/usage situation and may re-sult in the malfunction or failure at different times of the above-mentioned products/components including their electrical/electroni-cal ciruitry.Wear parts are all components subject to rotary or dynamic strain in-cluding electronic components under tension, in particular:
- Seals (incl. mechanical seal), seal ring- Stuffing box - Bearing and shaft- Impellers and pump part- Ball race and wear ring-Wear ring / wear plate-Macerator - Capacitor- Relay / contactor / switch- Electronic circuits, semiconductor components etc.
Pumps and continuous-flow machines (like submersible mixers and recirculation pumps), as well as their components with coatings (cat-aphoresis coating, 2K- or Ceram-coating) are subject to constant wear due to the abrasive fluid contents. It is for that reason that the coating is also listed with the wearing parts contained in these units!
We do not accept liability for faults or defects arising from natural tear and wear.
Wilo General terms of delivery and service
The latest version of our general terms of delivery and service can be found on the Internet at
www.wilo.com
Material Meaning
1.4021 Chromium steel X20Cr13
1.4057 Chromium steel X17CrNi16-2
1.4112 Chromium steel X 90 Cr Mo V 18
1.4122 Chromium steel X39CrMo17-1
1.4301 Chromium nickel steel X5CrNi18-10
1.4305 Chromium nickel steel X8CrNiS18-9
1.4306 Chromium nickel steel X2CrNi19-11
1.4308 Chromium nickel steel GX5CrNi19-10
1.4401 Chromium nickel molybdenum steel X5CrNiMo17-12-2
1.4408 Chromium nickel molybdenum steel GX5CrNiMo19-11-2
1.4462 Chromium nickel molybdenum steel X2CrNiMoN22-5-3
1.4470 Chromium nickel molybdenum steel GX2CrNiMoN22-5-3
1.4517 Chromium nickel molybdenum with copper addition GX2CrNiMoCuN25-6-3-3
1.4541 Chromium nickel steel with titanium addition X6CrNiTi18-10
1.4542 Chromium nickel steel with copper and niobium ad-dition X5CrNiCuNb16-4
1.4571 Chromium nickel steel with titanium additionX6CrNiMoTi17-12-2
1.4581 Chromium nickel molybdenum steel with niobium addition GX5CrNiMoNb19-11-2
Ceram Coating with very high adhesive strength, protection from corrosion and abrasion
EN-GJL Cast iron (with lamellar graphite)
EN-GJS Cast iron (with spheroidal cast iron)
G-CuAl10Si Nickel aluminium bronze
G-CuSn10 Zinc-free bronze
GG see EN-GJL
GGG see EN-GJS
NiAl-Bz Nickel aluminium bronze
Noryl Glass reinforced plastic
PC Polycarbonate
SiC Silicon carbide
ST Steel
St. vz. Galvanized steel
V2A (A2) Material group, e.g. 1.4301, 1.4306
V4A (A4) Material group, e.g. 1.4404, 1.4571
8 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
Fields of application, principle of operation and standards
Planning guide Borehole pumps Fields of application, principle of operation and standards Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"Fields of applicationWilo submersible pumps are designed for the economic, environmen-tally safe and hygienic pumping of potable water, mineral water, thermal water and industrial water. They are therefore also increas-ingly being installed, in addition to their traditional field of applica-tion i.e. installation in deep wells in pits, collection, storage and intermediate tanks, as well as in lakes, dams and rivers.
The product portfolio is divided into three segments: Building services / domestic water supply: Application in domestic
water supply and for irrigation from deep wells and rainwater storage tanks; rainwater utilisation and industrial water supply in the domes-tic sector; as well as fountains and potable water supply
Municipal and industrial water supply: Water pumping and pressure boosting from deep wells and rainwater storage tanks; water control in domestic and professional applications; decentralised water sup-ply; sprinkling and irrigation from deep wells, lakes and rivers; ground water preservation and lowering in street construction and open-pit mining; industrial pumping of cooling and industrial water; sea water applications, desalination systems and thermal water, sprinkler and fire extinguishing installations
Polder pumps: Sea water applications, particularly in offshore envi-ronments
Design and principle of operationSubmersible pumps are centrifugal pumps which form a compact unit together with the motor. They pump clean or slightly muddy water, require no maintenance and are distinguished by their high efficiency and long service life. The hydraulic component, single-stage or mul-ti-stage in single-stream sectional design, has radial or semi-axial impellers, depending on the required flow rate. The housing has re-placeable stationary wear rings in the sealing gap area of the impel-lers. Shielded, fluid-lubricated friction bearings are used as bearings for the blades. Pressure connection optionally with non-return valve or pressure port with threaded or flange connection.
Single-phase or three-phase squirrel-cage motors with waterproof insulated windings are used as submersible motors. The motor filling is potable water or a Wilo-specific factory filling (antifreeze-protect-ed). This is used for cooling the winding and for lubricating the fric-tion bearings. Volume compensation while heating and cooling is achieved by means of a relief diaphragm in the lower part of the mo-tor. The hydraulic axial thrust of the pump and the rotor weight are absorbed by the axial friction bearings. The motor is sealed against the fluid with a mechanical seal (SiC bearing surfaces) and/or with ro-tary shaft seals at the shaft outlet. The power cable connection with the motor is direct and pressure-tight.
StandardsWilo submersible pumps are subject to the following standards:
DIN EN ISO 9001The Wilo quality system ensures that the quality standards are com-plied with in all operational areas in accordance with DIN EN ISO 9001:2000
CE conformityFulfilment of the technical safety requirements of the EU Machinery Directive for pumps and pump units; visible documentation of this matter is provided by the CE mark shown on every pump
KTW approvalKTW approval has been granted for the unproblematic use of plastic components, power cables and coatings in potable water
ISO 9906International standard for the inspection of pumps
DIN EN 60034 (VDE)European standard for all electric motors
VdS certificateThe certificate documents the high quality and reliability of products specially made for fire protection
9
Planning guideBorehole pumps
Water extraction and supply
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Planning guide Borehole pumps Water extraction and supply Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"Water extractionWater is one of the most important elements in existence. Water is necessary for life to emerge and for life to be maintained. Neverthe-less, water is not to be found everywhere and it can usually not be used in its natural form. Water extraction therefore comes first and is something that can be accomplished in a wide variety of ways.
Rain waterRain water is to be found almost everywhere, depending on local rainwater heights. Water supply on this basis is however very uncer-tain, due to its irregular and unpredictable distribution. Another fac-tor to consider is that, because of its composition, rainwater is not immediately suitable as a source of potable water.
Surface waterRiver waterRiver water is exposed to the highest degree of contamination and is therefore the least suitable source for potable water supply. It is only when no other water is available that river water should be resorted to.
Because of its extreme quality fluctuations, river water is mainly used as a source of industrial water supply. The level of contamination is frequently so high that its economical use as water supply is either not possible at all or only to a limited extent. In order to extract water with low levels of particles in suspension, to achieve a better temper-ature progression and to simplify the water treatment process, at-tempts are made - to the extent permitted by the respective geolog-ical formations - to utilise river-bank filtrate. In addition, river water is increasingly being applied for artificial groundwater replenishment.
Lake waterLow-nutrient, deep lakes with sufficient inflow are the ones chiefly suitable for lake water extraction. Unlike flat lakes, lakes with depths exceeding around 40 m have a similar temperature equilibrium to that of ground water. The quality of the water depends essentially on the intake of contamination from the feeders of the catchment area and from the shore areas, as well as on the utilisation of the lake (e.g. leisure and recreation). Generally speaking, only the mean annual in-flow is extractable, minus losses, while the volume of the lake has a compensatory effect.
Reservoir waterReservoir dam basins are created by the artificial damming of river valleys. They are able to accumulate large potable water and industri-al water reserves while at the same time acting as storage basins for regulating the drainage fluctuations of rivers and as water storage systems for hydroelectric installations (multipurpose reservoir dams). The water level in the storage basin of a reservoir dam generally fluc-tuates considerably, depending on the extraction of the water for the intended use. The varying water level in the reservoir basins is the es-sential difference between these artificial lakes and natural lakes, which generally speaking have less water level fluctuations. The wa-ter quality is, as is the case with natural lakes, determined by the quality of the inflow from the catchment area.
Sea waterThe majority of all rainfall originates from evaporation that takes place in the atmosphere above the world's oceans, thus making them decisive for water management. The earliest attempts to desalinate sea water date back to antiquity. Nonetheless, the question of the extraction of potable water and industrial water has become increas-ingly urgent over the past 40 years, particularly in the arid and semi-arid parts of the world. Fully developed constructions are already available for desalination installations, but the emphasis here is on developing systems that offer even higher performance levels.
Ground waterGround water from sand layers is the most suitable type for potable water and domestic purposes. It is to be found in the vicinity of river courses, in glacial valleys and sandy deposits left over from the ice ages.
Porous soils (sands, gravels, etc.) have a filtering and thus a purifying effect that is entirely or partially absent in fissured stone formations (contiguous crevassed spaces). When the ground water has spent enough time in porous ground and has flowed a sufficiently long dis-tance, it will take on the mean ground temperature (8 - 12 C) and become germ-free. These properties (consistent temperature, good taste, absence of germs, etc.) make the ground water a particularly suitable source of potable water supply.
Organic and inorganic substances are absorbed and dissolved by the ground layers through which the water passes. The salts that are in solution are not eliminated by the filtration effect of the ground. If harmful or troublesome limits are exceeded, then the ground water requires treatment. The dissolving power for gases increases the deeper the water is and the higher the pressure thus is.
Water purificationOnce the water has been extracted, it must then be treated for the respective requirements. The water passes through a water treat-ment plant for this purpose. Water purification is for the purpose of accommodating the untreated water to the requirements of potable water and process water usage.
Water purification essentially consists of two groups of treatment: Removal of substances from the water (e.g. purification, sterilisation, removal of iron, softening, desalination)
Addition of substances and adjustment of the parameters of the wa-ter (e.g. dosage, adjustment of pH value, ions in solution and conduc-tivity)
Which processes are used depends on the utilisation and the degree of contamination of the water:
Technical water (cooling and process water for power plants, chemi-cal processes, pharmaceuticals) frequently require a very extensive modification of the water properties, e.g. by means of desalination, demineralised water, reverse osmosis, special dosages, degasifica-tion.
Legal specifications (Drinking Water Directive 98/93/EC) and the re-quirements of the distribution system are decisive for adjusting the potable water properties. Potable water can be preset by mixing wa-ter from a variety of sources in order to achieve a more homogeneous quality (e.g. a mixture of river-bank filtrate and reservoir dam water).
Bathing water in open air and indoor swimming pools is treated in ac-cordance with DIN 19643. Flocculation, filtration and chlorine disin-fection are the standard procedures.
Water treatment is frequently necessary when waters with different compositions are mixed. The pH value in mixed water is frequently shifted thereby to such an extent that the calcite solution capacity (i.e. the capacity of the water to dissolve calcium carbonate) exceeds permissible levels (according to the TrinkwV (German drinking water ordinance), the limit value for the calcite solution capacity is 5 mg/l). This ability to dissolve calcium carbonate is frequently referred to as the aggressiveness, or more precisely, the "calcium aggressiveness" of the water.
10 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
Water extraction and supply
The treatment of ground water from a sufficiently shielded aquifer is as a rule less complex than that of spring or surface water. The re-moval of iron and of manganese are probably the most frequently used methods for the treatment of ground water. The question of to what extent the chlorination of the ground water is required usually depends on the condition of the pipe system. However, more sophis-ticated processes are used for the treatment of surface water. These frequently include ozoning, flocculation with subsequent sedimenta-tion or filtration and activated carbon filtration for the elimination of absorbable pollutants. These processes are followed by an obligatory disinfection.
Mechanical, chemical and biological processes are applied for water purification.
Water purification processes
Process System components Purpose
Screening Rake, sieve drum, micro-strainer Removal of large solids and floating matter
Sedimentation Grit chamber, settling tank Removal of smaller floating matter, sand, floccula-ted suspended solids
Filtration Filters, sand filters Removal of suspended solids (particles)
Flotation Flotation basin Removal of fine dirt particles by blowing in air
Flocculation Flocculation basin Removal of colloid substances and fine dirt parti-cles by adding flocculants (discharging the parti-cles) and adjusting the pH value. Can also com-bined with a filtration (flocculation filtration).
Precipitation Precipitation basin and/or precipitation filtrati-on
Precipitation of impurities, e.g. iron or manganese oxides by ventilation and subsequent sedimentati-on or filtration.
Adsorption Active carbon filter Agglomeration of, for example, adsorbable haloge-nated hydrocarbon compounds (AOX) or dyes
Deacidification Deacidification unit Removal of aggressive carbonic acids. Used to pre-vent corrosion in the pipework.
Softening Water softener unit Removal of Ca2+ and Mg2+
Desalination Desalination unit Removal of salts, e.g. for converting sea water into potable water and for irrigation
Stripping Stripping basin Removal by blowing in air/gases. Depending on the vapour pressure, this causes water constituents in solution to be transferred to the gas phase and thus to be removed from the water.
Cooling Cooling towers, cooling ponds, heat ex-changers, etc.
Reduction of the temperature in order to fulfil the requirements of subsequent processes or usage.
Biochemical processes Example: Denitrification Exploitation of biochemical processes. With denit-rification, the nitrate content of contaminated, untreated water is reduced by adding carbon either underground or in a reactor.
Disinfection Special basin, additives introduced into the pipework
Sterilisation due to the introduction of chlorine or ozone or by UV radiation
Special treatment Special basin for contaminated sewage Special treatment of sewage that is contaminated with initially unknown substances or organisms. Examples: Untreated sewage from galvanisation plants or threadworms.
11
Planning guideBorehole pumps
Water extraction and supply
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Water storage tanksThe water must be placed in intermediate storage after it has been treated for the respective application. Storage facilities for potable water or process water are referred to as water storage tanks or water reservoirs.
Types of reservoirsA distinction is made between natural and artificial reservoirs. Natural reservoirs are, for example, oceans and seas, lakes and rivers above ground or ground water. Artificial reservoirs are, for example, under-ground tanks or reservoirs formed by dams.
Underground tanksThe water level of the storage tank is lower than that corresponding to the supply pressure. The water must therefore be pumped up out of the tank for supply purposes. Underground tanks are therefore suction tanks for pumping station units and are used for compensa-tion between spring water inflow or preliminary well pumping and raising the water into the supply system. With pressure vessel pump-ing stations, they also assume some of the tasks of elevated tanks, such as the compensation of consumption fluctuations or the stor-age of fire-fighting water.
Fire water tankVery frequent, and in the case of small rural communities almost al-ways necessary, is the storage of fire water in special fire water tanks, e.g. when no central water supply is available or when the water sup-ply in the elevated tank is not sufficient for fighting major fires. Sur-face water can also be used for filling purposes, since the water is not subject to any special hygienic or technical requirements. Generally, nearby ponds are equipped with the equipment required for extract-ing fire water or artificial fire protection ponds (fire ponds) are creat-ed. Underground fire water tanks are on the other hand more practi-cal in closed areas covered with buildings.
Elevated tankThe most common form of water storage and the one to be used in most central water supply systems is in elevated tanks. These are wa-ter storage tanks in which the water level is higher than the supply area from which the water falls along a natural gradient to flow into the supply system. They are used for compensating consumption fluctuations, for maintaining a consistent pressure in the supply sys-tem, for emergency supplies and for the storage of a water reserve for fire-fighting purposes, with long-distance lines and with group water supply systems such as interim tanks and zone tanks.
If the elevated tank is set up at an appropriate height, then it also provides the required supply pressure. It is possible to have elevated tanks arranged at different static heads in order to provide different pressure stages (hilly countryside). Tanks are, however, used not only for water storage but also for pressure reduction; it is primarily in supply networks with large static head differentials that so-called discharge flow-through tanks are used, since otherwise the pressure at the lowest point of the water supply system would be too great.
Ground-level tankThe water storage tank is set up at a favourable location in terms of altitude and position, with most of the structure installed under-ground and covered with earth. This form of elevated tank is fre-quently preferred, because it is the most economic and reliable type available.
Water towerWater towers can store only small amounts of water, but neverthe-less provide sufficient pressure for the pipe systems below them due to their static head.
If no favourably positioned ground site is available, then water stor-age is carried out in the vicinity of the supply area in water chambers which are located, in the upper part of a tower-like building struc-ture. The water tower is occasionally designed as a standpipe tower, where the bottom of the water chamber is the foundation bed. The costs of a water tower are considerably higher than those of a ground-level container (around 5 to 10 times as high). The water lev-el of the storage tank is therefore generally not positioned as high above the supply area as is the case with a ground-level tank, and its volumetric capacity is kept smaller.
12 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
Well-sinking
Planning guide Borehole pumps Well-sinking Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"Well-sinking is used for the installation of structures for pumping ground water. A cover and a lateral sealing of the sump or of the borehole to the surface are used to protect the wells against the infil-tration of contamination. The water can be pumped using various pump models, such as submersible pumps. Water extraction is based on the yield of the ground water source and the performance of the filtration system, which must prevent any flushing out of the ground into the well.
TypesShaft wellManual or mechanical excavation is used to open up a vertical sump down to the body of the ground water. The pit is secured with ma-sonry or finished parts prefabricated with (reinforced) concrete as it is deepened. The flow of the ground water to the well takes place through the bottom of the sump and/or of a vertical filtration system. This procedure is only suitable for lesser depths (generally considera-bly less than 40 m).
Usually the construction of a shaft well is as follows for a simple de-sign with minor depths and individual objects (this work is dangerous and should be performed by a specialist company):
Concrete sump rings (diameter e.g. 1 000 mm) are used. A small amount of earth is dug out, upon which the first well casing
(without step irons) is placed in exact horizontal position. This first ring casing can be given a steel blade on its underside.
The earth under the first well casing is excavated, the well casing sinks accordingly and additional well casings can be placed on top of it.
Abyssinian wellA pipe with a cone end and a filtration system arranged underneath (open part of the pipe) is driven down as far as the ground water level by ramming it. This method is particularly favoured by hobby handy-men for small installations and lesser depths. These wells called Ab-yssinian wells are also referred to by specialists in Germany as "Bau-haus wells". Advantage: Easy to set up. Disadvantage: Last only approximately 5 years.
Bore well / vertical wellDrilling is carried out down to the ground water body. A filtration sys-tem is provided in the water-carrying layer. This method can be used for great depths (more than 1000 m).
Horizontal filter wellStarting in a sump, horizontal drillings with filtration systems are pushed forward into the ground water body. These wells enable large extraction quantities.
13
Planning guideBorehole pumps
Use in sprinkler systems
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Planning guide Borehole pumps Use in sprinkler systems Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"Sprinkler systems are automatic fire extinguishing systems which are used for fire prevention in special building structures such as sky-scrapers, commercial buildings, department stores, industrial instal-lations, places of public assembly and underground car parks.
The sprinkler head was invented in 1874 by the American Henry S. Parmalee, a piano manufacturer. The water spraying nozzles were originally sealed with a small metal plate which was held in place by a device connected to a solder. The solder melts with a corresponding rise in temperature and the retaining device releases the small metal plate, which is in turn expelled by the pressure of the water behind it, which then starts spraying.
Several sprinkler heads that are connected to a water pipe system are fitted on the ceiling of the room or on the upper part of the side walls. The sprinkler heads are in turn sealed with glass ampoules that are filled with a special dyed fluid. A constant water pressure prevails in-side a sprinkler system that is monitored at the central sprinkler con-trol point. In the event of a fire, the special fluid in the glass ampoules heats up and expands, causing the ampoules to burst. This opens the nozzles and water is released from the sprinkler pipe network. The colour of the special fluid indicates the triggering temperature. This triggering temperature is on average approximately 30 C above the anticipated room temperature.
The resulting drop in pressure is detected, which leads to the opening of special valves and the starting of our sprinkler pumps. Water is im-mediately pumped at high pressure out of the tanks provided for this or from a water connection designed for that purpose and into the sprinkler system. The water is expelled from all open water nozzles and extinguishes or minimises the fire.
The dimensions of the pipework and of the water supply are designed in such a way that only enough water for a specific number of water nozzles is available, which is called the effective surface. If more sprinkler heads open than are available on the effective surface, then the amount of water available per sprinkler head drops and the effec-tiveness of the systems is reduced.
Sprinkler systems are therefore primarily for fighting a fire in its initial stages (incipient fire) and not for fighting a blazing fire. A fireproof partition must be erected between areas that lack a sprinkler system and ones that have one in order to ensure that a blazing fire originat-ing in an unprotected area is not able to cross over into an area of the building that is protected with a sprinkler system.
What are called dry pipe systems are used in areas where there is a risk of frost causing the sprinkler lines to freeze up. The pipe system in these installations is filled with compressed air. The installation is not filled with water until a sprinkler head is triggered.
As is the case with conventional fire detectors, sprinkler control points are generally connected to fire detection systems and trigger a fire alarm when a drop in pressure has been detected. Depending on the programming, this is transmitted to the police, fire department, factory security office or other offices providing aid.
As a rule, the configuration of sprinkler systems in Germany is in ac-cordance with the VdS Regulation CEA 4001 (VdS Damage Preven-tion, CEA Comit Europen des Assurances). The American Standard of the NFPA (National Fire Protection Association) - also known in modified or further developed form of the directives as FM (Factory Mutual) Standard - is however increasingly enjoying the favour of in-ternational building companies and is as a rule also accepted in the meantime by German government authorisation agencies. The sys-tem is configured according to the fire hazard level in the area to be protected by determining the water saturation of the fire source be-tween 2.25 mm/min and 30 mm/min (1 mm/min is equivalent to 1 l/m2/min), the effective time between 30 and 90 min and of the dis-tance between the sprinkler heads.
14 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
Offshore applications
Planning guide Borehole pumps Offshore applications Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"DefinitionThe term "offshore installations" refers to structures permanently lo-cated either on the open sea or in coastal areas. An example of this is an oil rig.
Platforms are referred to as oil rigs if they are used to bore holes in the sea bed for the purpose of tapping crude oil and natural gas fields.
TypesThere are different types of oil rigs. Our pumps are used chiefly on the following two types:
Jack-up rig: This platform stands on the rig's legs which in turn stand on foundations on the sea bed. The platform can be moved vertically i.e. along the legs. The internal structure of the platform is thereby used partially as a ballast tank which is filled with sea water. Trans-port is performed by special ships. Jack-up rigs are usually to be found in flat water.
Semi-submersible rig: The platform floats on pontoons, which ensure the buoyancy of the structure while being used at the same time as ballast tanks. It is possible to keep the oil rig itself stable, even under adverse weather conditions, by filling or emptying the ballast tanks. Positioning above the borehole is ensured by the use of an anchor or by its own drives. This type of oil rig is very mobile and can be used in water depths down to approximately 1800 m.
MaterialsSea water is an extremely corrosive fluid. To be able to use pumps in it, materials which are resistant to sea water must be used . All parts that come into contact with the fluid in our units that are made for use in sea water are either made of bronze or stainless steel or are coated with Ceram. The use of these high-quality materials makes it possible to achieve a long service life of the pumps.
ApplicationSubmersible pumps or polder pumps and submersible sewage pumps are used on oil rigs.
On jack-up rigs, the submersible pumps are installed either on the rig's legs or on the derrick itself. They pump sea water on to the deck where it is then distributed to various consumers, e.g. the fire-fight-ing system.
The submersible pumps are also installed on the derrick on semi-submersible rigs and pump like with jack-up rigs sea water on to the deck. In addition, polder pumps are installed in the ballast tanks in order to fill or empty them.
Submersible sewage pumps are used for the rapid filling of the ballast tanks on jack-up rigs before the platform is raised to its working height.
Oil rig equipmentThe complete equipment and planning of our units on oil rigs is car-ried out by our partner, the S&N Pump Company in Houston, Texas (www.snpump.com).
15
Planning guideBorehole pumps
Offshore applications
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Design of an oil rig
Figure, jack-up rig: 1.) Permanent water curtain, 2.) Submersible sewage pump in frame, freely suspended in seawater, 3.) Installation of the submersible pump on the water tower, 4.) Installation of the submersible pump on the rig's legs; Image source: S&N Pump Company
1
2
3
4
16 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
Material selection by water analysis
Planning guide Borehole pumps Material selection by water analysis Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"CorrosionA preliminary assessment of the corrosion potential for pump unit components can be done based on a water analysis. The passivity of any material in terms of the pumped fluid requires that a suitable protective layer is formed on the surface that is in contact with the fluid. In the case of grey cast iron, this is what is called the "lime-rust protective layer" which, depending on the composition of the pumped water, can form and help prevent further corrosion. Two cri-teria are necessary for the successful effect of this protective layer:
Fig. 1: Tendency to deposit limy layers
Fig. 2: Chemical resistance of the deposited protective layer to the existing carbonic acid
Tendency to deposit limy layers according to Fig. 1Main parameters: pH value and carbonate hardness and/or acid ca-pacity KS 4,3 of the pumped water.
Chemical resistance of the deposited protective layer to carbon acidic according to Fig. 2. Main parameters: Free CO2 content and carbonate hardness / acid ca-pacity KS 4,3 (the aggressive range is equivalent to the free, non-cor-responding CO2 content).
The line shown in the figure represents the equilibrium curve (GK) between supporting and damaging any layer formation or its incapa-bility. In the "aggressive" range (on a grey background), materials are probably vulnerable to corrosion in the absence of protective layers. In such cases we recommend our special version C or D made of more corrosion-resistant materials.
Only the carbonate hardness (sum of calcium and magnesium bicar-bonate Ca(HCO3)2 + Mg(HCO3)2) is decisive for the formation of the protective layer, not the overall hardness.
Additional constituents and/or parameters of natural waters can have a damaging effect on the resistance of standard materials above the specified concentrations:
SO42 approx. 200 mg/l
Cl- approx. 150 mg/l Evaporation residues approx. 500 mg/l Electrical conductivity approx. 1000 S/cm And traces of Cl2, H2S, NH3, NH4, sulphur, humic acids, hydrocarbons.
The presence of combinations of these constituents, even in smaller concentrations, can cause materials to be corroded. The warmer an aggressive fluid is, the faster it corrodes a material. If critical sub-stances are present, please consult us at the company. Wilo offers technically mature special versions even for aggressive fluids, such as sea water or brackish water.
Formation of troublesome coatings and depositsCoatings impair the pumping capacity and/or heat dissipation of the drive motor. Undesired deposits may be formed if there is an exces-sive tendency toward lime deposits according to Fig. 1 (hard water) (e.g. iron approx. 0.2 mg/l or manganese approx. 0.1 mg/l, ochre coatings or manganese dioxide).
Solid matter in the pumped fluidIf the pumped fluid contains solid matter, material may be deposited in the pump - depending on its content and composition. Wilo sub-mersible pumps are designed for a maximum sand content of 35 mg/l. Pumps with components made of more wear-resistant materials on request.
Gaseous constituentsSome applications require the pumping of gaseous fluids (e.g. mineral and thermal water). Gas bubbles can considerably change the pump-ing characteristics under certain circumstances and can lead to unfa-vourable operating conditions. Please consult us at the factory in such cases.
pH(20 C)
9,0
0 2 4 6 8 10 KH [dH]161412 22
6,0
6,5
7,0
7,5
8,0
GK
1 42 3 5 6 KS 4,3 80
CO2[mg/l]
160
120
100
80
60
40
20
0
KH [dH]
GK
0 2 4 6 8 10 161412 22
1 42 3 5 6 KS 4,3 80
17
Planning guideBorehole pumps
Design of a Wilo-EMU pump
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Planning guide Borehole pumps Design of a Wilo-EMU pump Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"Technical design1 Power cableWith KTW approval for potable water
2 Screwed connectionsFast and inexpensive dismantling using screwed connections made of stainless steel.
3 Rubber bearing sleeve Functions as a highly wear-resistant end bearing. High resistance to sand and vibrations.
4 ImpellersWear-resistant impellers made of high-quality cast bronze. Precise power adjustment possible due to trimming of the semi-axial impel-lers.
5 Stationary wear ringsMade of special bronze, they are wear-resistant and easy to replace and are therefore with low operating costs.
6 HousingStandard version made of grey cast iron and special version made of zinc-free bronze.
7 Pump connectionFor the unproblematic connection of motors with NEMA (4", 6". 8") and standard connection.
8 Motor shaft sealingMechanical seal made of highly wear-resistant silicon carbide for long service life.
9 Pump and motor shaftsAreas in contact with the pumped fluid are always made of stainless steel; thus high wear and corrosion resistance, as well as long service life.
10 Bearing sleeveDouble bearing sleeve made of special artificial carbon with spiral grooves for cooling and lubrication
11 Motor monitoringTemperature monitoring option in the motor.
12 Motor shroudMade of stainless steel or zinc-free bronze, depending on the type and version.
13 Counter-thrust bearingFor absorbing the negative axial thrust
14 Thrust bearingFriction bearing lubrication by means of motor filling, with independ-ent tilting segments or single-disc thrust bearing for the absorption of high axial loads.
15 Relief diaphragmsVolume compensation when motor filling is heated up/cooled down.
18 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
General cable-laying principles
Planning guide Borehole pumps General cable-laying principles Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Permissible constant load for the power cables at higher ambient temperatures
Temperature range [C] 3135 3640 4145 4650 5155 5660
Constant load [%] 96 91 87 82 76 65
Calculation of the line cross-section for three-phase current
Direct activation with multi-wire line Star/delta activation with multi-wire line
Calculations:Voltage loss UV:
Key:A[mm2]=line cross-section
C=direct activation and starting transformer: 3.1
direct activation, 2 parallel lines: 1.55
star-delta activation: 2,1
I[A]=nominal current
L[m]=single line length
Lk [m]=current cable length
PV [%]=line dissipation
U[V]=operating voltage
UV [%]=voltage loss
cos=power factor for I
Power dissipation PV:
Cable length for other voltages:
When determining the line cross-section, note that the voltage drop UV must not exceed 3 %.
U = 400 VUv = 3 %t = 30 CCos = 0,85 = 44-54
600
I[A]
300
200
150
100
80
6050
40
30
20
15
10
8
65
4
3
210 15 20 30 40 50 60 80 100 150 200 300 L [m] 500
1,5 mm
2,5 mm
4 mm
6 mm
10 mm
16 mm
25 mm
35 mm
50 mm
70 mm
95 mm
U = 400 VUv = 3 %t = 30 CCos = 0,85 = 44-54
600
I[A]
300
200
150
100
80
6050
40
30
20
15
10
8
65
4
3
210 15 20 30 40 50 60 80 100 150 200 300 L [m] 500
1,5 mm
2,5 mm
4 mm
6 mm
10 mm
16 mm
25 mm
35 mm
50 mm
70 mm
95 mm
Uv = [%]C x I L cos
A x U
Pv = [%]Uv
Cos
L = x Lk [m]400U
19
Planning guideBorehole pumps
Wilo-EMU products for cable-laying
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Planning guide Borehole pumps Wilo-EMU products for cable-laying Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Permissible maximum water temperature: 60 CPermissible constant load according to VDE at 30 C ambient tem-perature and 90 C conductor temperatureNominal voltage Uo/U = 450/750 V; laid in protection tube or well 600/1000 V
In addition, the VDE regulations relating to line installation, short-cir-cuit current and ambient temperature are to be complied with for the selection of the cross-section.All cables are BAM-tested (BAM = Bundesanstalt fr Materialprfung = German Federal Institute for Materials Testing)Tolerance for line dimensions: - 10 %
Line dimensioning
Line cross-section [mm2]1.5 2.5 4 6 10 16 25 35 50 70 95
Single-wire line
Direct activation / starting transformer
[A] 149 197 244 304 376 453
Star-delta activation
[A] 257 340 422 525 650 783
[mm] 13.1 15.2 17.4 18.5 20.8 23
[kg/m] 0.255 0.36 0.485 0.67 0.89 1.2
Multi-wire line with 3 and 4 wires
Direct activation / starting transformer
[A]23 30 41 53 74 99 131 162 202 250 301
Star-delta activation
[A]40 52 71 92 128 171 227 280 350 433 521
[mm]16 21.4 25.9 31 35.3 40.6 45.1 50
[kg/m]0.37 0.665 1.02 1.46 1.99 2.72 3.47 4.2
[mm]12 13.9 16.1 18.4 23.9 28.8 34 38.8 44.6 49.8 55
[kg/m]0.175 0.25 0.355 0.47 0.81 1.26 1.87 2.50 3.42 4.56 5.7
[mm] 8.1x16.4
[kg/m] 0.18
[mm] 7.3x18.4
8.3x21.4
9.3x25.5
10.5x28.6
14.5x36.4
16.9x44.3
[kg/m]0.175 0.25 0.345 0.47 0.81 1.21
20 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
Wilo-Sub products for cable-laying
Planning guide Borehole pumps Wilo-Sub products for cable-laying Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"Electrical connection of Wilo submersible pumpsCable lengths and cross-sectionsThe cable cross-sections required for the electrical connection of Wi-lo submersible pumps depend on the length of the connection cable, the mains voltage and on the motor power and starting mode of the motors. This data can be obtained from the following table.Each motor cable can be extended with the respective motor cable cross-section by at least a minimum of 30 m.
For more planning information, see Wilo "Borehole technology" plan-ning guide.
Maximum possible cable length and required cable cross-section
Mains-
conn
ectio
n Motor power
Cable cross-section 4 x n (mm2)
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400
[kW] Max. possible cable length [m]
Direct
starting
3~40
0 V 50
Hz or
3~3
80 V
60 Hz
2.2 120 199 317 472 7753 90 154 245 364 5984 69 114 182 271 444 6855.5 50 83 130 197 324 5097.5 40 66 105 156 257 404 61611 45 72 107 176 278 423 57715 80 132 208 317 452 59518.5 65 107 168 256 348 481 64522 90 142 215 295 407 545 70430 108 164 223 306 408 522 62237 86 131 179 248 335 434 524 62345 112 152 209 279 358 426 502 58055 124 170 228 293 351 414 481 57175 129 173 223 267 316 367 437 500 58393 134 172 205 241 279 330 375 433110 145 174 205 237 281 320 370
Star-delta
starting
3~40
0 V 50
Hz or
3~3
80 V
60 Hz
2.2 180 299 476 708 11633 135 231 368 546 8974 104 171 273 407 666 10285.5 75 125 195 296 486 7647.5 60 99 158 234 386 606 92411 68 108 161 264 417 635 86615 120 198 312 476 678 89318.5 98 161 252 384 522 722 96822 135 213 323 443 611 818 105630 162 246 335 459 612 783 93337 129 197 269 371 503 651 786 935
Direct
starting
1~23
0 V 50
Hz
0.25 190 320 510 770 1260 1970 2960 3990 5340 6970 87500.37 120 210 330 500 820 1290 1950 2640 3560 4680 59100.55 80 140 230 350 580 900 1360 1830 2450 3210 40200.5 60 110 180 270 440 690 1050 1430 1930 2550 32301.1 40 70 120 190 310 490 750 1020 1390 1860 23801.5 30 60 100 150 250 400 620 850 1180 1590 20702.2 20 40 60 100 170 270 410 560 770 1030 13203.7 40 60 110 170 260 370 520 710 930
The knowledge database from Wilo.
500 answers to FAQs.Used 9000 times in 14 days.
1001 new suggestions.For even more expert knowledge.
Did you know? The knowledge database from Wilo will give you good and quickadvice: with approx. 500 responses to the most frequently asked questions (FAQs)all about pumps, installations and systems. It is already being visited extensively bymany skilled craftsmen.This is proven by 9000 utilisations in only 14 days, which werecently registered. The best thing: With every new question which you ask uswith the contact form, we all become wiser together. Because the correspondinganswer is naturally incorporated as soon as possible. Know-how? We call this Pumpen Intelligenz.
www.wilo.com
22 Subject to change 09/2008 WILO SE
Planning guideBorehole pumps
Equipment/FunctionPlanning guide Borehole pumps Equipment/Function Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub TWU 3 ...
Wilo-Sub TWU 4 ...
Wilo-Sub TWU 4-QC ...
Wilo-Sub TWU 3 Plug & Pump ...
Wilo-Sub TWU 4 Plug & Pump ...
Wilo-Sub TWU 6-..-B/TWU 8-..-B ...
Design
NEMA connection Standardised connection
Integrated non-return valve Without non-return valve
Single-phase motor Three-phase motor Direct activation Star-delta activation FC operation Motor with cast stator Rewindable motor Oil motor filling Water-glycol motor filling Potable water motor filling
Hydraulics/motor preassembled
Application
Horizontal installation Vertical installation
Equipment/function
Motor temperature monitoring, PT100 optional
Motor temperature monitoring, PTC Capacitor box for 1~230 V Dry-running protection system Integrated lightning protection
Accessories
Bearing brackets for horizontal installation
Cooling jacket optional optional optional optional optional optional
Non-return valve
Pressure shroud
Materials
Pump housing Stainless steel Grey cast iron
Pump housing (special version)
Impeller Plastic Plastic Plastic Plastic Plastic Bronze
Impeller (special version)
Motor housing Stainless steel
Motor housing (special version)
23
Planning guideBorehole pumps
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Equipment/FunctionPlanning guide Borehole pumps Equipment/Function Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub TWI 4-..-B
Wilo-Sub TWI 6-..-B
Wilo-Sub TWI 8-..-B
Wilo-EMU 6" ...
Wilo-EMU 8" ...
Wilo-EMU 10" ... 24" ...
Wilo-EMUpolder pumps ...
Design
NEMA connection Standardised connection Integrated non-return valve Without non-return valve Single-phase motor Three-phase motor Direct activation Star-delta activation FC operation Motor with cast stator Rewindable motor Oil motor filling
Water-glycol motor filling Potable water motor filling optional optional optional optional optional optional
Hydraulics/motor preassembled
Application
Horizontal installation Vertical installation
Equipment/function
Motor temperature monitoring, PT100 optional optional optional optional optional optional optional
Motor temperature monitoring, PTC optional optional optional optional optional optional optional
Capacitor box for 1~230 V Dry-running protection system optional optional optional optional optional optional optional
Integrated lightning protection
Accessories
Bearing brackets for horizontal installation optional optional optional optional optional
Cooling jacket optional optional optional optional optional optional
Non-return valve optional optional optional optional
Pressure shroud optional optional optional optional optional optional
Materials
Pump housing 1.4301 1.4301 1.4301
On customer request
Pump housing (special version) 1.4404 1.4404 1.4404
Impeller 1.4301 1.4301 1.4301
Impeller (special version) 1.4404 1.4404 1.4404
Motor housing 1.4301 1.4301 1.4301
Motor housing (special version) 1.4401 1.4401 1.4401
24 Subject to change 09/2008 WILO SE
Water supply
Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P
Water supply Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Series: Wilo-Sub TWU 3
>Application For water supply from boreholes, wells and rainwater storage
For domestic water supply, sprinkling and ir-rigation
For pumping water without long-fibre and abrasive constituents
Series: Wilo-Sub TWU 4
>Application For water supply from boreholes and rain-
water storage For domestic water supply, sprinkling and ir-rigation
Pressure boosting Lowering the water level For pumping water without long-fibre and abrasive constituents
Series: Wilo-Sub TWU 4-QC
>Application For water supply from boreholes and rain-
water storage For domestic water supply, sprinkling and ir-rigation
Pressure boosting Lowering the water level For pumping water without long-fibre and abrasive constituents
Wilo-SubTWU 3-...H
[m]
0 0,50
20
40
60
80
100
1,0 1,5 2,0 Q[m/h]
-0115
-0123
-0130
-0145
Wilo-SubTWU 4-...
-08.. -16..-02.. -04..
Q[m/h]
H[m
]
0 5 10 15 20
240
200
160
120
80
40
0
-02.. -04.. -08..
0
20
40
60
80
100
120
140
0 2,5 5 7,5 12,510
H[m
]
Q[m/h]
Wilo-SubTWU 4-...-QC
25
Water supply
Water
supply
Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Water supply Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Series: Wilo-Sub TWU 3
>Special features/product benefits Motor with rewindable stator Integrated non-return valve Parts in contact with fluid are corrosion-free Pump connection head and flange made of stainless steel Vertical and horizontal installation possible Single-phase version with starting capacitor and On/Off switch
Series: Wilo-Sub TWU 4
>Special features/product benefits Parts in contact with fluid are corrosion-free Integrated non-return valve Vertical and horizontal installation possible
Series: Wilo-Sub TWU 4-QC
>Special features/product benefits Parts in contact with fluid are corrosion-free Integrated non-return valve Quick and easy extension of motor cable, without dismantling the pump Vertical and horizontal installation possible
>More information Page Series description . . . . . . . . . . . . . . . . . 34
>More information Page Series description . . . . . . . . . . . . . . . . . 39
>More information Page Series description . . . . . . . . . . . . . . . . . 54
26 Subject to change 09/2008 WILO SE
Water supply
Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P
Water supply Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Series: Wilo-Sub TWU 3 Plug & Pump
>ApplicationWater-supply unit for
Water supply from boreholes, wells and rainwater storage
Domestic water supply, sprinkling and irri-gation
Pumping water without long-fibre and abrasive constituents
Series: Wilo-Sub TWU 4 Plug & Pump
>ApplicationWater-supply unit for self-sufficient water supply in the domestic sector
Washing machines Garden sprinkling Transferring by pumping and filling Taps for process water
H[m
]
80
Wilo-TWU 3-..Plug & Pump50 Hz
7060504030201000 0,5 1,0 1,5 2,0 2,5Q[m/h]
TWU 3 0130TWU 3 0123TWU 3 0115
0 1 2 3 4 5
50
25
75
0Q[m/h]
H[m
]
Wilo-Sub TWU 4-...Plug & Pump
27
Water supply
Water
supply
Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Water supply Series overview Wilo-Sub TWU3, TWU4, TWU4-QC, TWU3 P&P, TWU4 P&P Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Series: Wilo-Sub TWU 3 Plug & Pump
>Special features/product benefits Electrical system components prewired for installation Easy installation and operation Integrated non-return valve
Series: Wilo-Sub TWU 4 Plug & Pump
>Special features/product benefits Simple assembly, installation and operation Reliable motor, due to high starting torque and shake-free function Lightning and overload protection built into the motor Integrated non-return valve
>More information Page Series description . . . . . . . . . . . . . . . . . 65
>More information Page Series description . . . . . . . . . . . . . . . . . 70
28 Subject to change 09/2008 WILO SE
Water supply
Technical dataWater supply Technical data Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub...
Mains
con
nection
Max
. volum
e flo
w
Maximum
delivery head
Max
. sand content
Fluid temperature
Min
. flo
w rate
at the
motor
Insulatio
n class
Protectio
n class
Max
. sub
mersion
depth
Max
. switching
frequency
Q H v
[m3/h] [m] [g/m3] [m/s] [m] [1/h]
TWU 3-0115 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0115 3~400 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0123 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0123 3~400 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0130 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0130 3~400 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0145 3~400 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 4-0207-C 1~230 V, 50 Hz 2.5 46 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0207-C 3~400 V, 50 Hz 2.5 46 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0210-C 1~230 V, 50 Hz 2.5 68 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0210-C 3~400 V, 50 Hz 2.5 68 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0214-C 1~230 V, 50 Hz 2.5 91 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0214-C 3~400 V, 50 Hz 2.5 91 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0227-B 1~230 V, 50 Hz 2.5 130 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0227-B-EMSC 1~230 V, 50 Hz 2.5 130 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0227-B 3~400 V, 50 Hz 2.5 130 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0232-B 1~230 V, 50 Hz 2.5 153 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0232-B-EMSC 1~230 V, 50 Hz 2.5 153 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0232-B 3~400 V, 50 Hz 2.5 153 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0246-B 1~230 V, 50 Hz 2.5 218 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0246-B-EMSC 1~230 V, 50 Hz 2.5 218 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0246-B 3~400 V, 50 Hz 2.5 218 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0260-B 1~230 V, 50 Hz 2.5 284 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0260-B-EMSC 1~230 V, 50 Hz 2.5 284 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0260-B 3~400 V, 50 Hz 2.5 284 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0405-B 1~230 V, 50 Hz 5 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0405-B-EMSC 1~230 V, 50 Hz 5 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0405-B 3~400 V, 50 Hz 5 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0407-B 1~230 V, 50 Hz 5 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0407-B-EMSC 1~230 V, 50 Hz 5 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0407-B 3~400 V, 50 Hz 5 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0410-B 1~230 V, 50 Hz 5 62 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0410-B-EMSC 1~230 V, 50 Hz 5 62 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0410-B 3~400 V, 50 Hz 5 62 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0415-B 1~230 V, 50 Hz 5 93 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0415-B-EMSC 1~230 V, 50 Hz 5 93 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0415-B 3~400 V, 50 Hz 5 93 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0420-B 1~230 V, 50 Hz 5 124 50 3 C ... 30 C 0.1 B IP 68 200 20
Voltage tolerance +/- 10 % (specification according to DIN EN 60034)
29
Water supply
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Materials
Water
supply
Water supply Materials Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub...
Impeller
(stand
ard)
Impeller
(special
version
)
Pump ho
using
Pump ho
using
(special
version
)
Pump shaft
Pump shaft
(special
version
)
Motor
hou
sing
Motor
hou
sing
(special
version
)
Motor
shaft
Motor
shaft
(special
version
)
TWU 3-0115 PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0115 PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0123 PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0123 PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0130 PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0130 PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0145 PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0207-C Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0207-C Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0210-C Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0210-C Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0214-C Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0214-C Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0227-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0227-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0227-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0232-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0232-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0232-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0246-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0246-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0246-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0260-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0260-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0260-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0405-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0405-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0405-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0407-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0407-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0407-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0410-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0410-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0410-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0415-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0415-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0415-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0420-B PC 1.4301 1.4104 1.4301 1.4305
30 Subject to change 09/2008 WILO SE
Water supply
Technical dataWater supply Technical data Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub...
Mains
con
nection
Max
. volum
e flo
w
Maximum
delivery head
Max
. sand content
Fluid temperature
Min
. flo
w rate
at the
motor
Insulatio
n class
Protectio
n class
Max
. sub
mersion
depth
Max
. switching
frequency
Q H v
[m3/h] [m] [g/m3] [m/s] [m] [1/h]
TWU 4-0420-B-EMSC 1~230 V, 50 Hz 5 124 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0420-B 3~400 V, 50 Hz 5 124 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0430-B 1~230 V, 50 Hz 5 182 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0430-B-EMSC 1~230 V, 50 Hz 5 182 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0430-B 3~400 V, 50 Hz 5 182 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0440-B 3~400 V, 50 Hz 5 242 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0445-B 3~400 V, 50 Hz 5 273 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0450-B 3~400 V, 50 Hz 5 303 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0804-B 1~230 V, 50 Hz 12 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0804-B-EMSC 1~230 V, 50 Hz 12 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0804-B 3~400 V, 50 Hz 12 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0806-B 1~230 V, 50 Hz 12 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0806-B-EMSC 1~230 V, 50 Hz 12 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0806-B 3~400 V, 50 Hz 12 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0808-B 1~230 V, 50 Hz 12 57 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0808-B-EMSC 1~230 V, 50 Hz 12 57 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0808-B 3~400 V, 50 Hz 12 57 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0812-B 1~230 V, 50 Hz 12 83 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0812-B-EMSC 1~230 V, 50 Hz 12 83 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0812-B 3~400 V, 50 Hz 12 83 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0817-B 3~400 V, 50 Hz 12 119 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0820-B 3~400 V, 50 Hz 12 139 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0824-B 3~400 V, 50 Hz 12 169 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0830-B 3~400 V, 50 Hz 12 211 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1607-B 1~230 V, 50 Hz 22 40 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1607-B-EMSC 1~230 V, 50 Hz 12 40 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1607-B 3~400 V, 50 Hz 22 40 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1610-B 1~230 V, 50 Hz 22 56 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1610-B-EMSC 1~230 V, 50 Hz 12 56 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1610-B 3~400 V, 50 Hz 22 56 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1614-B 3~400 V, 50 Hz 22 76 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1619-B 3~400 V, 50 Hz 22 105 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1626-B 3~400 V, 50 Hz 22 138 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-1634-B 3~400 V, 50 Hz 22 180 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0207-C-QC 1~230 V, 50 Hz 2.5 46 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0207-C-QC 3~400 V, 50 Hz 2.5 46 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0210-C-QC 1~230 V, 50 Hz 2.5 68 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0210-C-QC 3~400 V, 50 Hz 2.5 68 50 3 C ... 30 C 0.1 B IP 68 200 20
Voltage tolerance +/- 10 % (specification according to DIN EN 60034)
31
Water supply
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Materials
Water
supply
Water supply Materials Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub...
Impeller
(stand
ard)
Impeller
(special
version
)
Pump ho
using
Pump ho
using
(special
version
)
Pump shaft
Pump shaft
(special
version
)
Motor
hou
sing
Motor
hou
sing
(special
version
)
Motor
shaft
Motor
shaft
(special
version
)
TWU 4-0420-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0420-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0430-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0430-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0430-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0440-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0445-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0450-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0804-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0804-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0804-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0806-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0806-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0806-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0808-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0808-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0808-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0812-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0812-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0812-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0817-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0820-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0824-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0830-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1607-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1607-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1607-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1610-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1610-B-EMSC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1610-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1614-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1619-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1626-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-1634-B PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0207-C-QC Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0207-C-QC Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0210-C-QC Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0210-C-QC Noryl 1.4301 1.4104 1.4301 1.4305
32 Subject to change 09/2008 WILO SE
Water supply
Technical dataWater supply Technical data Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub...
Mains
con
nection
Max
. volum
e flo
w
Maximum
delivery head
Max
. sand content
Fluid temperature
Min
. flo
w rate
at the
motor
Insulatio
n class
Protectio
n class
Max
. sub
mersion
depth
Max
. switching
frequency
Q H v
[m3/h] [m] [g/m3] [m/s] [m] [1/h]
TWU 4-0214-C-QC 1~230 V, 50 Hz 2.5 91 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0214-C-QC 3~400 V, 50 Hz 2.5 91 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0232-B-QC 1~230 V, 50 Hz 2.5 153 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0232-B-QC 3~400 V, 50 Hz 2.5 153 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0405-B-QC 3~400 V, 50 Hz 5 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0407-B-QC 1~230 V, 50 Hz 5 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0407-B-QC 3~400 V, 50 Hz 5 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0410-B-QC 1~230 V, 50 Hz 5 62 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0410-B-QC 3~400 V, 50 Hz 5 62 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0415-B-QC 1~230 V, 50 Hz 5 93 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0415-B-QC 3~400 V, 50 Hz 5 93 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0420-B-QC 3~400 V, 50 Hz 5 124 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0430-B-QC 3~400 V, 50 Hz 5 182 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0804-B-QC 1~230 V, 50 Hz 12 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0804-B-QC 3~400 V, 50 Hz 12 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0806-B-QC 3~400 V, 50 Hz 12 42 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0812-B-QC 3~400 V, 50 Hz 12 83 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0817-B-QC 3~400 V, 50 Hz 12 119 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 3-0115-Plug&Pump/FC 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0115-Plug&Pump/DS 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0123-Plug&Pump/FC 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0123-Plug&Pump/DS 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0130-Plug&Pump/FC 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 3-0130-Plug&Pump/DS 1~230 V, 50 Hz 2.6 125 40 3 C ... 40 C 0.1 F IP 58 60 20
TWU 4-0405-B-Plug&Pump/FC 1~230 V, 50 Hz 5 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0405-B-Plug&Pump/DS 1~230 V, 50 Hz 5 30 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0410-B-Plug&Pump/FC 1~230 V, 50 Hz 5 62 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0410-B-Plug&Pump/DS 1~230 V, 50 Hz 5 62 50 3 C ... 30 C 0.1 B IP 68 200 20
TWU 4-0415-B-Plug&Pump/DS 1~230 V, 50 Hz 5 93 50 3 C ... 30 C 0.1 B IP 68 200 20
Voltage tolerance +/- 10 % (specification according to DIN EN 60034)
33
Water supply
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Materials
Water
supply
Water supply Materials Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub...
Impeller
(stand
ard)
Impeller
(special
version
)
Pump ho
using
Pump ho
using
(special
version
)
Pump shaft
Pump shaft
(special
version
)
Motor
hou
sing
Motor
hou
sing
(special
version
)
Motor
shaft
Motor
shaft
(special
version
)
TWU 4-0214-C-QC Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0214-C-QC Noryl 1.4301 1.4104 1.4301 1.4305
TWU 4-0232-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0232-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0405-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0407-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0407-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0410-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0410-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0415-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0415-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0420-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0430-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0804-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0804-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0806-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0812-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0817-B-QC PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0115-Plug&Pump/FC PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0115-Plug&Pump/DS PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0123-Plug&Pump/FC PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0123-Plug&Pump/DS PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0130-Plug&Pump/FC PC 1.4301 1.4104 1.4301 1.4305
TWU 3-0130-Plug&Pump/DS PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0405-B-Plug&Pump/FC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0405-B-Plug&Pump/DS PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0410-B-Plug&Pump/FC PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0410-B-Plug&Pump/DS PC 1.4301 1.4104 1.4301 1.4305
TWU 4-0415-B-Plug&Pump/DS PC 1.4301 1.4104 1.4301 1.4305
34 Subject to change 09/2008 WILO SE
Water supplySingle pumps
Series description Wilo-Sub TWU 3
Water supply Single pumps Series description Wilo-Sub TWU 3 Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
DesignSubmersible-motor pump, multistage
Type key
Application For water supply from boreholes, wells and rainwater storage For domestic water supply, sprinkling and irrigation For pumping water without long-fibre and abrasive constituents
Special features/product benefits Motor with rewindable stator Integrated non-return valve Parts in contact with fluid are corrosion-free Pump connection head and flange made of stainless steel Vertical and horizontal installation possible Single-phase version with starting capacitor and On/Off switch
Technical data Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz Immersed operating mode: S1 Fluid temperature: 3-40 C Minimum motor flow: 0.08 m/s Max. sand content: 40 g/m3 Max. number of starts: 20/h Max. submersion depth: 60 m Protection class: IP 58 Pressure port: Rp 1
Equipment/function Multistage submersible-motor pump with radial impellers Integrated non-return valve NEMA coupling Single-phase or three-phase AC motor Integrated thermal motor protection for single-phase motor
Materials Hydraulic housing: 1.4301 stainless steel Impellers: polycarbonate Hydraulics shaft: 1.4104 stainless steel Motor housing: 1.4301 stainless steel Motor shaft: 1.4305 stainless steel
Description/designSubmersible-motor pump for vertical or horizontal installation.
HydraulicsMultistage submersible-motor pump with radial impellers with sec-tional construction. Integrated non-return valve. All parts in contact with the fluid are made of corrosion-free materials.
MotorCorrosion-free single-phase or three-phase AC motor for direct starting, with rewindable stator, oil-filled, self-lubricating bearings.
CoolingThe motor is cooled by the fluid. The motor must always be immersed when operated. The limit values for maximum fluid temperature and minimum flow velocity must be adhered to. Vertical installation is possible with or without cooling jacket. Cooling jacket is required for horizontal installation.
Options Motor versions for 3~230 V, 50 Hz; 1~230 V, 60 Hz; 3~380 V, 60 Hz
Scope of delivery Hydraulics + motor fully mounted 1.8 m connecting cable in accordance with VDE/KTW with 4x1.5 mm2 cross-section
Single-phase version including switchbox with capacitor, thermal motor protection and On/Off switch
Installation and operating instructions
Accessories Cooling jacket pipes Diaphragm pressure vessel Cable kits for potable and process water Float switch Switchgears Connection and installation material
e.g. Wilo-Sub TWU 3-0115
TWU Submersible pump3 Diameter of the hydraulic unit in inches ["]01 Nominal volume flow [m3/h]15 Number of hydraulic stages
35
Water supplySingle pumps
Water
supply
Series description Wilo-Sub TWU 3
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Wilo-Sub TWU 3-...H
[m]
0 0,50
20
10
40
30
60
50
80
90
70
100
110
120
1,0 1,5 2,0 2,5 Q [m/h]
TWU 3-0115
TWU 3-0123
TWU 3-0130
TWU 3-0145
36 Subject to change 09/2008 WILO SE
Water supplySingle pumps
Wilo-Sub TWU 3-01..
Water supply Single pumps Wilo-Sub TWU 3-01.. Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Pump curves Wilo-Sub TWU 3-01..
1~230 V or 3~400 V, 50 Hz, p = 1 kg/dm3, v = 1x10-6 m2/s, ISO 9906 Annex A
0 0,5 1 1,5 2 2,5
0,10 0,2 0,3 0,4 0,5 0,6 0,7
0 1 2 3 4 5 6 7 8 9 10
Q [m/h]
0 0,5 1 1,5 2 2,5 Q [m/h]
[l/s]
[lgpm]
H [m]
p [%]
0
40
60
100
80
120
140
20
30
50
90
70
110
130
10
70
60
50
40
20
30
TWU 3-0115
TWU 3-0123
TWU 3-0130
TWU 3-0145
37
Water supplySingle pumps
Water
supply
Wilo-Sub TWU 3-01..
Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Water supply Single pumps Wilo-Sub TWU 3-01.. Subject to change 09/2008 WILO SE Wilo Catalogue B2 - 50 Hz - Borehole pumps 3" to 24"
Motor data
Wilo-Sub... Mains connection Motor diameter Nominal motor power Nominal currentLength