IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 5
avenue® c
FAVC
SUSPENDED favcS
SURfacE MOUNT favcS-SM
WaLL MOUNT favcW
kEy
WEighTS
favcS
4' - 9lbs | 8' - 18lbs
favcW
4' - 13lbs | 8' - 26lbs
POWER Off
POWER ON
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.
aTTENTiON
aDDiTiONaL iNSTRUcTiONS
LEvELUNivERSaL SUSPENSiON SySTEM - ShiPS SEPaRaTELy
U- iNDiviDUaL
S- STaRT Of RUN
U- iNDiviDUaL
S- STaRT Of RUN
U- iNDiviDUaL
S- STaRT Of RUN
i- iNTERMEDiaTE
E- END Of RUN
i- iNTERMEDiaTE
E- END Of RUN
i- iNTERMEDiaTE
E- END Of RUN
USE SiNgLE DEvicE cOvER OR SiNgLE gaNg haNDy bOx (by OThERS)MOUNTiNg haRDWaRE (by OThERS)
j-bOx (by OThERS)
IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 5
LENS ONLy
FoLLow FoCAL PoINT INSTRuCTIoNS FoR
uNIVERSAL SuSPENSIoN SySTEm ASSEmbLy.
SEE IS0166
houSINg/uNIT X
4' individual/start 47.5"
4' intermediate/end 48.0"
8' individual/start 95.5"
8' intermediate/end 96.0"
1
324
75 26
8 29
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.
SuSPENDED (FAVCS)
22X
MakE ELEcTRicaL cONNEcTiONS
LENS ONLy
IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 5
LENS ONLy
LENS ONLy 312
64 25
978
10
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.
SuRFACE mouNT (FAVCS-Sm)
MakE ELEcTRicaL cONNEcTiONS
SECURE HOUSING TO STRUCTURE ABOVE. (HARDWARE BY OTHERS.)
IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 5
LENS ONLy
fEED LOcaTiONS
21
3 4
25
8
6
79
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing.
wALL mouNT (FAVCw)
3' & 6' housings
all housing lengths
center cutout on j-box
LOCATE J-BOX CENTER & INSTALL (J-BOX BY OTHERS)
LOCATE MOUNTING RAIL
INSTALL REMAINING RAILS. REMOVE END SECTION FROM LAST RAIL IN RUN.
18"
4' & 8' housings
luminaire outline
luminaire outline
luminaire outline
24"
3.33"3.33"
3.33"
3.70"
3.70"
3.70"
MakE ELEcTRicaL cONNEcTiONS
A
B
C
(FASTENERS BY OTHERS)
(FASTENERS BY OTHERS)
Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited.
IS0229 REV. D 2011 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 5 of 5
LENS ONLy
14
12
213
bALLAST SERVICE (SuRFACE mouNT ShowN)
wALL mouNT (FAVCw) - CoNTINuED
LENS ONLy2
4
13
11
MakE ELEcTRicaL cONNEcTiONS
210