Transcript
Page 1: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+- +-

Are you seArching for the right connections?They’re righT here aT MarconnecT.

Marconnect. Data Processing

our new dig i ta l hand he ld measur ing inst ruments are equipped with Marconnect inter face capabi l i ty. regard less

of which inter face standard you use , whether u sB , opto r s232 or Dig imat ic ; Marconnect wi l l a lways prov ide you with

the opt imal connect ion .

the latest information on MArconnect products can be found on our website: www.mahr.com, Webcode 213

Page 2: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+- +-

USB ready / Marcom Software

overviewMarconnect USB ready 11- 2simple data transmission to a Pc as well as enables quick and universal assembly of a multiple measuring station. Marcom Software 11- 3clear and flexible data acquisition

Statistics Printer

Marconnect MSP2 11- 5statistics printer with integrated Data Logger

interfaces

Marconnect T-Box 11- 6interface to connect to a Pc keyboard input

radio Transmission

Marconnect radio System FM 1 11- 7secure and wireless data transmission

overviewMarconnect Data connection cables 11- 8to connect Measuring instruments to Data Printers & external Devices

Marconnect. Data Processing

Marconnect. Data Processing

Page 3: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-2

� � � � �

�������������

• Easily extendablewith additionalUSBhubs

• Multiple measuring station iseasilysetupwithaUSBhub,

upto100measuringdevicescanbesimultaneously

connected

• Clear and flexible data acquisitionwiththeeasytouseMarComProfessionalSoftware

• CompatiblewithallMarConnect USBreadymeasuringinstruments

MarConnect. USBreadyThe new f l ex ib le MarConnect i n te r face f rom

Mahr. S imp l i f i es bo th da ta t ransmi s s ion to a PC

and enab les qu i ck and un i ve r sa l a s semb ly o f a

mu l t ip l e measu r ing s ta t ion .

• Choose alternative methods of data transmissioneitherwithafootswitchoraPCkeyboard,directonthemeasuringinstrumentorwiththeTimerfunction

MarConnect. DataProcessing

Page 4: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+

11-�

MarCom Software

IBMATcompatiblePCMSWindows®2000,XP,VistaUSBinterface,higherthan1.1upto10MBCD/DVDdriveRecommended:MSExcelfromVersion97onwards Order no.

Software MarCom Professional 4102552Software MarCom Standard 4102551

System Requirements

Software MarCom Professional •Measuredvaluescanbe

directlytransferredintoeitherMSExcel(fromversion97)orintoatextfileorkeycode

•Themeasuredvaluesfromeachinstrumentcanbesenttoadifferentcolumn,tableorfolderinExcel

•Datatransmissionispossiblevia.USBand2serialCOMinterfaces

•USBhubisalsosuitableasameasuringinstrumentinterface

•Upto100measuringinstrumentscanbeconnectedwithUSBdatacable

•Clearportrayalofthechosenmeasuringinstrmentswiththeaidoficons

•SeveralfootswitchescanbeconnectedupviaUSB.Measuringinstrumentscanbefreelyassigned

•Freelydefinableandconfigurablemeasurementcycles

•Thereareavarietyofwaystotransmitdata,youcaneitherpressthe“Data“buttononthemeasuringinstrumentoronthedatacable;viaacomputer,timer,keyboard;orbyactivatingafootswitchconnectedtoaUSBinterface

•Textfilecanbeeditedthustranslatedindiverselanguages

Software MarCom Standard(USBcableisnotincludedinthescopeofsupply)

FeaturesandsystemrequirementsareidenticaltoMarComProfessional,exceptthatitonlyhasoneUSBandoneserialCOMinterface

Features

MarConnect. DataProcessing

Page 5: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-4

�������

��������������

� � � � ����������

����

DataConnectionCable16 EXuOrder no. 4102�57incl.MarComStandard

forMarCal.Calipers16EX/EXP16EXV18EX/EXP30EX/EXN

forDigimar.HeightGages814S

forMicromar.Micrometers40EX,40EWS,40EWV44EX,46EX

DataConnectionCable2000 usbOrder no. 4�4602�incl.MarComStandard

forMarCator.Dig.Indicators1088

DataConnectionCableMC-IOrder no. 4102782incl.MarComStandard

forFoot switchOrder no. 4102058

USB-HUB7-foldindustrialmodel220 V Order no. 410255�110 V (US type) Order no. 2245786

USB readyMeasuringInstruments

forMarCator.Dig.Indicators1075,1080,1081,1086,1087

forMillimess.DigitalComparators200020012100

MarConnect. DataProcessing

Page 6: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-6

T-Box 204 USB

MarConnect. DataProcessing

Digi-USB-1 Interface USBInterfacewithoneDigimaticinputport

Features

•PowersuppliedbytheUSBinterface

•NodriverrequiredfortheUSBinterface

•TheUSBinterfaceis recognizedasakeyboard•Terminationcharactersuchas

EnterorTABcanbesetupontheUSBinterface

•Data-keyfordata transmission

•Suppliedwith: USB-Interface

1xDigimatic-measuringinstrument-inputDimensions 20x57x33mm

Order no. 410252�

Technical Data

T-Box interfacetoconnecttomeasuringinstrumentstothekeyboardinputjackofaIBMcompatiblePC

Inputs Dimensions Order no. Remarks mm(LxWxH)

T-Box 204 USB 3xMulti-RS232CInput 130x180x40 9102519 WhenconnectingDigimatic- 1xDigimaticInput measuringinstrumentsthe standardcableoftheT-Box 205 USB 2xMulti-RS232CInput 130x180x40 4102579 manufacturercanbeused 3xDigimaticInput

Technical Data

Order no.

Foot Switch forconnectiontoT-Box 4102556Data Cable forconnectingmeasuringinstrumentsSeecableoverviewonPage11-8

Accessories

•Measuringdataisconvertedintokeyboard codes,

thereforesuitableforany softwarewithamanualinput

(e.g.MS-Excel®)•Nospecialdriversoftware

required•Independentofoperating

system(DOS,Windows, OS/2,Unix,Linux)•Measuringvaluescanbe

processedindividuallyorasagroup

•Themeasuredvaluescanbedirectlytriggeredonthe

measuringinstrumentorwiththeoptionalfootswitch

Features

•EveryMulti-RS232Cinterfaceisindividuallyadjustableviathesetupswitch

•Terminationcharacter(e.g.Enter)canbeselectedviaswitch

•ThepowerissuppliedbytheUSBinterface

•Suppliedwith: USBcable PS/2cable

Note: OnlysuitableforGerman,French,USkeyboardsorcompatible!

Page 7: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+

11-7

Send confirmation

Sendmeasuring value

DATA-Button

Confirmation,acoustic

Confirmation, optical

-OK

-Transmissionerror

Transmitter

������

MarConnect. DataProcessing

Radio Transmission RadiosystemFM1*

•Securedatatransmissionwithdialoguebetweenreceiverandtransmitter

•Acousticandopticalconfirmationofreceiptbythetransmitter

•Compacttransmitterisconnecteddirectlyontheinterfaceofthemeasuringinstrument

Features

For Measuring Instruments Order no.

MarCal 16EX,16EXC,16EXV, 16 EXt 4102�21 18EX,30EX,30EXNDigimar 814SMicromar 40EX,44EX,46EX,40EWS,40EWVMarCator 1075,1080,1081,1086,1087

MarCal 25ES,30EWD,31ES,32ES 16 ESt 4102�22Digimar 27ES,M814MarTool 106ES

Millimar C1208,C1216,C1245,S1840 RS2�2 t 2121�15Digimar CX1,CX2,817CLM

ContactMahrFederalfortransmitterstobeusedwith: µMaxµm Digimaticdevices Digimaticdatacables

Transmitter

Order no.

ReceiverforUSB FM 1 4102�20interfacesincl.driverandbasicsoftware.BasicsoftwareconsistsofasoftwarekeyboardinterfaceandsoftwaretostoremeasuredvaluesinanMS-Excel®column.

Receiver

Order no.

Mahr_EXDLL(optional) 4102�2�SoftwareforstoringmeasuringdataofseveralradiomodulesinanyExceltable.ContactMahrFederalforoptionalMSExcelbasedsoftwarethatallowfor:• Datamanipulationofupto120datainputs• FullSPCandgraphicaldisplays

Optional Software

•PowerissuppliedforthereceiverviaaUSB-InterfaceonthePC

•Upto120measuringinstrumentscanbeconnectedtothereceiver

•Radiotransmissiondistanceisfrom10mupto200m

(dependingontheenvironment)

•Radiofrequencyis433.926MHz

ThetransmissionofthemeasuredvaluetakesplaceviaactuationoftheDATAbuttononthetransmitter.Thetransmittersupplementsthemeasuredvaluewithanaddressnumber,acommunicationcontrolwordandadoublechecksum.ThespecialdatacodingandthefeedbackfromthePCtothetransmitterensuresabsolutedatasecurity.AtransmissionerrorisrecognizedbythedialoguebetweenPCandtransmitter.ThedatatransmissionisthenrepeateduptothreetimesautomaticallywithinafewmillisecondsWhenthedataissuccessfullytransmittedthegreenlightonthetransmitterflashesandashortbeepisheardconfirmingtransmission.

* Only available in North America, Canada and Mexico

Page 8: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-8

DigimaticRS232C������

MarConnect. InterfacesOverview

① OnlyavailableinNorthAmerica,CanadaandMexico② Footswitch;onlywithanadditionalUSBPort③ Cablelength18cm/7”

④ Datatransmissiononlywiththe“Data“keyor“automatic transmisison“onthemeasuringinstrument⑤ Footswitchtotransferdataonthemeasuringinstrument Millimar-Orderno.5330956/Millimar1240-Orderno.5312431

Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via

Instrument MarCom Software MarCom Software USB

FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058

16EX/EXC

16EXV

18EX

30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411

40EX,40EWS,40EWV,

46EX,44EX

1075,1080,1081,1086,1087

814S

2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021

1088

838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥

MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035

µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025

25ES

30EWD

31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510

106ES

M814

MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------

1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634

C1208,C1216

DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④

MarConnect. DataProcessing

--------

Page 9: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+

11-9

4102715 / 70246�4

41024104102�57 4102411

4�4602� 4�46020

2001025 / 22�90�7 / 4495084 ⑥

4102510

4�46021

4102��0 to 4102��4 ⑥

4102058

4102711

4102782 ③

MarConnect . Regard lessof which inter facestandardyouuse , whether ; U SB , OptoR S232oderDig imat ic , MarConnect a lwaysprov idesyouwith theopt imumconnect ion .

Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via

Instrument MarCom Software MarCom Software USB

FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058

16EX/EXC

16EXV

18EX

30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411

40EX,40EWS,40EWV,

46EX,44EX

1075,1080,1081,1086,1087

814S

2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021

1088

838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥

MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035

µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025

25ES

30EWD

31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510

106ES

M814

MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------

1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634

C1208,C1216

DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④

⑥ Cablelength1.5m/5ft⑦ NotforMillimar1240

Standardcablelength2m

MarConnect. DataProcessing

--------


Recommended