Are you seArching for the right connections?They’re righT here aT MarconnecT.
Marconnect. Data Processing
our new dig i ta l hand he ld measur ing inst ruments are equipped with Marconnect inter face capabi l i ty. regard less
of which inter face standard you use , whether u sB , opto r s232 or Dig imat ic ; Marconnect wi l l a lways prov ide you with
the opt imal connect ion .
the latest information on MArconnect products can be found on our website: www.mahr.com, Webcode 213
+- +-
USB ready / Marcom Software
overviewMarconnect USB ready 11- 2simple data transmission to a Pc as well as enables quick and universal assembly of a multiple measuring station. Marcom Software 11- 3clear and flexible data acquisition
Statistics Printer
Marconnect MSP2 11- 5statistics printer with integrated Data Logger
interfaces
Marconnect T-Box 11- 6interface to connect to a Pc keyboard input
radio Transmission
Marconnect radio System FM 1 11- 7secure and wireless data transmission
overviewMarconnect Data connection cables 11- 8to connect Measuring instruments to Data Printers & external Devices
Marconnect. Data Processing
Marconnect. Data Processing
-
11-2
� � � � �
�������������
• Easily extendablewith additionalUSBhubs
• Multiple measuring station iseasilysetupwithaUSBhub,
upto100measuringdevicescanbesimultaneously
connected
• Clear and flexible data acquisitionwiththeeasytouseMarComProfessionalSoftware
• CompatiblewithallMarConnect USBreadymeasuringinstruments
MarConnect. USBreadyThe new f l ex ib le MarConnect i n te r face f rom
Mahr. S imp l i f i es bo th da ta t ransmi s s ion to a PC
and enab les qu i ck and un i ve r sa l a s semb ly o f a
mu l t ip l e measu r ing s ta t ion .
• Choose alternative methods of data transmissioneitherwithafootswitchoraPCkeyboard,directonthemeasuringinstrumentorwiththeTimerfunction
MarConnect. DataProcessing
+
11-�
MarCom Software
IBMATcompatiblePCMSWindows®2000,XP,VistaUSBinterface,higherthan1.1upto10MBCD/DVDdriveRecommended:MSExcelfromVersion97onwards Order no.
Software MarCom Professional 4102552Software MarCom Standard 4102551
System Requirements
Software MarCom Professional •Measuredvaluescanbe
directlytransferredintoeitherMSExcel(fromversion97)orintoatextfileorkeycode
•Themeasuredvaluesfromeachinstrumentcanbesenttoadifferentcolumn,tableorfolderinExcel
•Datatransmissionispossiblevia.USBand2serialCOMinterfaces
•USBhubisalsosuitableasameasuringinstrumentinterface
•Upto100measuringinstrumentscanbeconnectedwithUSBdatacable
•Clearportrayalofthechosenmeasuringinstrmentswiththeaidoficons
•SeveralfootswitchescanbeconnectedupviaUSB.Measuringinstrumentscanbefreelyassigned
•Freelydefinableandconfigurablemeasurementcycles
•Thereareavarietyofwaystotransmitdata,youcaneitherpressthe“Data“buttononthemeasuringinstrumentoronthedatacable;viaacomputer,timer,keyboard;orbyactivatingafootswitchconnectedtoaUSBinterface
•Textfilecanbeeditedthustranslatedindiverselanguages
Software MarCom Standard(USBcableisnotincludedinthescopeofsupply)
FeaturesandsystemrequirementsareidenticaltoMarComProfessional,exceptthatitonlyhasoneUSBandoneserialCOMinterface
Features
MarConnect. DataProcessing
-
11-4
�������
��������������
� � � � ����������
����
DataConnectionCable16 EXuOrder no. 4102�57incl.MarComStandard
forMarCal.Calipers16EX/EXP16EXV18EX/EXP30EX/EXN
forDigimar.HeightGages814S
forMicromar.Micrometers40EX,40EWS,40EWV44EX,46EX
DataConnectionCable2000 usbOrder no. 4�4602�incl.MarComStandard
forMarCator.Dig.Indicators1088
DataConnectionCableMC-IOrder no. 4102782incl.MarComStandard
forFoot switchOrder no. 4102058
USB-HUB7-foldindustrialmodel220 V Order no. 410255�110 V (US type) Order no. 2245786
USB readyMeasuringInstruments
forMarCator.Dig.Indicators1075,1080,1081,1086,1087
forMillimess.DigitalComparators200020012100
MarConnect. DataProcessing
-
11-6
T-Box 204 USB
MarConnect. DataProcessing
Digi-USB-1 Interface USBInterfacewithoneDigimaticinputport
Features
•PowersuppliedbytheUSBinterface
•NodriverrequiredfortheUSBinterface
•TheUSBinterfaceis recognizedasakeyboard•Terminationcharactersuchas
EnterorTABcanbesetupontheUSBinterface
•Data-keyfordata transmission
•Suppliedwith: USB-Interface
1xDigimatic-measuringinstrument-inputDimensions 20x57x33mm
Order no. 410252�
Technical Data
T-Box interfacetoconnecttomeasuringinstrumentstothekeyboardinputjackofaIBMcompatiblePC
Inputs Dimensions Order no. Remarks mm(LxWxH)
T-Box 204 USB 3xMulti-RS232CInput 130x180x40 9102519 WhenconnectingDigimatic- 1xDigimaticInput measuringinstrumentsthe standardcableoftheT-Box 205 USB 2xMulti-RS232CInput 130x180x40 4102579 manufacturercanbeused 3xDigimaticInput
Technical Data
Order no.
Foot Switch forconnectiontoT-Box 4102556Data Cable forconnectingmeasuringinstrumentsSeecableoverviewonPage11-8
Accessories
•Measuringdataisconvertedintokeyboard codes,
thereforesuitableforany softwarewithamanualinput
(e.g.MS-Excel®)•Nospecialdriversoftware
required•Independentofoperating
system(DOS,Windows, OS/2,Unix,Linux)•Measuringvaluescanbe
processedindividuallyorasagroup
•Themeasuredvaluescanbedirectlytriggeredonthe
measuringinstrumentorwiththeoptionalfootswitch
Features
•EveryMulti-RS232Cinterfaceisindividuallyadjustableviathesetupswitch
•Terminationcharacter(e.g.Enter)canbeselectedviaswitch
•ThepowerissuppliedbytheUSBinterface
•Suppliedwith: USBcable PS/2cable
Note: OnlysuitableforGerman,French,USkeyboardsorcompatible!
+
11-7
Send confirmation
Sendmeasuring value
DATA-Button
Confirmation,acoustic
Confirmation, optical
-OK
-Transmissionerror
Transmitter
������
MarConnect. DataProcessing
Radio Transmission RadiosystemFM1*
•Securedatatransmissionwithdialoguebetweenreceiverandtransmitter
•Acousticandopticalconfirmationofreceiptbythetransmitter
•Compacttransmitterisconnecteddirectlyontheinterfaceofthemeasuringinstrument
Features
For Measuring Instruments Order no.
MarCal 16EX,16EXC,16EXV, 16 EXt 4102�21 18EX,30EX,30EXNDigimar 814SMicromar 40EX,44EX,46EX,40EWS,40EWVMarCator 1075,1080,1081,1086,1087
MarCal 25ES,30EWD,31ES,32ES 16 ESt 4102�22Digimar 27ES,M814MarTool 106ES
Millimar C1208,C1216,C1245,S1840 RS2�2 t 2121�15Digimar CX1,CX2,817CLM
ContactMahrFederalfortransmitterstobeusedwith: µMaxµm Digimaticdevices Digimaticdatacables
Transmitter
Order no.
ReceiverforUSB FM 1 4102�20interfacesincl.driverandbasicsoftware.BasicsoftwareconsistsofasoftwarekeyboardinterfaceandsoftwaretostoremeasuredvaluesinanMS-Excel®column.
Receiver
Order no.
Mahr_EXDLL(optional) 4102�2�SoftwareforstoringmeasuringdataofseveralradiomodulesinanyExceltable.ContactMahrFederalforoptionalMSExcelbasedsoftwarethatallowfor:• Datamanipulationofupto120datainputs• FullSPCandgraphicaldisplays
Optional Software
•PowerissuppliedforthereceiverviaaUSB-InterfaceonthePC
•Upto120measuringinstrumentscanbeconnectedtothereceiver
•Radiotransmissiondistanceisfrom10mupto200m
(dependingontheenvironment)
•Radiofrequencyis433.926MHz
ThetransmissionofthemeasuredvaluetakesplaceviaactuationoftheDATAbuttononthetransmitter.Thetransmittersupplementsthemeasuredvaluewithanaddressnumber,acommunicationcontrolwordandadoublechecksum.ThespecialdatacodingandthefeedbackfromthePCtothetransmitterensuresabsolutedatasecurity.AtransmissionerrorisrecognizedbythedialoguebetweenPCandtransmitter.ThedatatransmissionisthenrepeateduptothreetimesautomaticallywithinafewmillisecondsWhenthedataissuccessfullytransmittedthegreenlightonthetransmitterflashesandashortbeepisheardconfirmingtransmission.
* Only available in North America, Canada and Mexico
-
11-8
DigimaticRS232C������
MarConnect. InterfacesOverview
① OnlyavailableinNorthAmerica,CanadaandMexico② Footswitch;onlywithanadditionalUSBPort③ Cablelength18cm/7”
④ Datatransmissiononlywiththe“Data“keyor“automatic transmisison“onthemeasuringinstrument⑤ Footswitchtotransferdataonthemeasuringinstrument Millimar-Orderno.5330956/Millimar1240-Orderno.5312431
Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via
Instrument MarCom Software MarCom Software USB
FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058
16EX/EXC
16EXV
18EX
30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411
40EX,40EWS,40EWV,
46EX,44EX
1075,1080,1081,1086,1087
814S
2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021
1088
838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥
MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035
µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025
25ES
30EWD
31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510
106ES
M814
MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------
1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634
C1208,C1216
DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④
MarConnect. DataProcessing
--------
+
11-9
4102715 / 70246�4
41024104102�57 4102411
4�4602� 4�46020
2001025 / 22�90�7 / 4495084 ⑥
4102510
4�46021
4102��0 to 4102��4 ⑥
4102058
4102711
4102782 ③
MarConnect . Regard lessof which inter facestandardyouuse , whether ; U SB , OptoR S232oderDig imat ic , MarConnect a lwaysprov idesyouwith theopt imumconnect ion .
Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via
Instrument MarCom Software MarCom Software USB
FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058
16EX/EXC
16EXV
18EX
30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411
40EX,40EWS,40EWV,
46EX,44EX
1075,1080,1081,1086,1087
814S
2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021
1088
838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥
MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035
µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025
25ES
30EWD
31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510
106ES
M814
MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------
1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634
C1208,C1216
DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④
⑥ Cablelength1.5m/5ft⑦ NotforMillimar1240
Standardcablelength2m
MarConnect. DataProcessing
--------