9
- ARE YOU SEARCHING FOR THE RIGHT CONNECTIONS? THEY’RE RIGHT HERE AT MARCONNECT. MarConnect. Data Processing Our new digital hand held measuring instruments are equipped with MarConnect interface capability. Regardless of which interface standard you use, whether USB, Opto RS232 or Digimatic; MarConnect will always provide you with the optimal connection. The latest information on MARCONNECT products can be found on our website: www.mahr.com, WebCode 213

Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+- +-

Are you seArching for the right connections?They’re righT here aT MarconnecT.

Marconnect. Data Processing

our new dig i ta l hand he ld measur ing inst ruments are equipped with Marconnect inter face capabi l i ty. regard less

of which inter face standard you use , whether u sB , opto r s232 or Dig imat ic ; Marconnect wi l l a lways prov ide you with

the opt imal connect ion .

the latest information on MArconnect products can be found on our website: www.mahr.com, Webcode 213

Page 2: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+- +-

USB ready / Marcom Software

overviewMarconnect USB ready 11- 2simple data transmission to a Pc as well as enables quick and universal assembly of a multiple measuring station. Marcom Software 11- 3clear and flexible data acquisition

Statistics Printer

Marconnect MSP2 11- 5statistics printer with integrated Data Logger

interfaces

Marconnect T-Box 11- 6interface to connect to a Pc keyboard input

radio Transmission

Marconnect radio System FM 1 11- 7secure and wireless data transmission

overviewMarconnect Data connection cables 11- 8to connect Measuring instruments to Data Printers & external Devices

Marconnect. Data Processing

Marconnect. Data Processing

Page 3: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-2

� � � � �

�������������

• Easily extendablewith additionalUSBhubs

• Multiple measuring station iseasilysetupwithaUSBhub,

upto100measuringdevicescanbesimultaneously

connected

• Clear and flexible data acquisitionwiththeeasytouseMarComProfessionalSoftware

• CompatiblewithallMarConnect USBreadymeasuringinstruments

MarConnect. USBreadyThe new f l ex ib le MarConnect i n te r face f rom

Mahr. S imp l i f i es bo th da ta t ransmi s s ion to a PC

and enab les qu i ck and un i ve r sa l a s semb ly o f a

mu l t ip l e measu r ing s ta t ion .

• Choose alternative methods of data transmissioneitherwithafootswitchoraPCkeyboard,directonthemeasuringinstrumentorwiththeTimerfunction

MarConnect. DataProcessing

Page 4: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+

11-�

MarCom Software

IBMATcompatiblePCMSWindows®2000,XP,VistaUSBinterface,higherthan1.1upto10MBCD/DVDdriveRecommended:MSExcelfromVersion97onwards Order no.

Software MarCom Professional 4102552Software MarCom Standard 4102551

System Requirements

Software MarCom Professional •Measuredvaluescanbe

directlytransferredintoeitherMSExcel(fromversion97)orintoatextfileorkeycode

•Themeasuredvaluesfromeachinstrumentcanbesenttoadifferentcolumn,tableorfolderinExcel

•Datatransmissionispossiblevia.USBand2serialCOMinterfaces

•USBhubisalsosuitableasameasuringinstrumentinterface

•Upto100measuringinstrumentscanbeconnectedwithUSBdatacable

•Clearportrayalofthechosenmeasuringinstrmentswiththeaidoficons

•SeveralfootswitchescanbeconnectedupviaUSB.Measuringinstrumentscanbefreelyassigned

•Freelydefinableandconfigurablemeasurementcycles

•Thereareavarietyofwaystotransmitdata,youcaneitherpressthe“Data“buttononthemeasuringinstrumentoronthedatacable;viaacomputer,timer,keyboard;orbyactivatingafootswitchconnectedtoaUSBinterface

•Textfilecanbeeditedthustranslatedindiverselanguages

Software MarCom Standard(USBcableisnotincludedinthescopeofsupply)

FeaturesandsystemrequirementsareidenticaltoMarComProfessional,exceptthatitonlyhasoneUSBandoneserialCOMinterface

Features

MarConnect. DataProcessing

Page 5: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-4

�������

��������������

� � � � ����������

����

DataConnectionCable16 EXuOrder no. 4102�57incl.MarComStandard

forMarCal.Calipers16EX/EXP16EXV18EX/EXP30EX/EXN

forDigimar.HeightGages814S

forMicromar.Micrometers40EX,40EWS,40EWV44EX,46EX

DataConnectionCable2000 usbOrder no. 4�4602�incl.MarComStandard

forMarCator.Dig.Indicators1088

DataConnectionCableMC-IOrder no. 4102782incl.MarComStandard

forFoot switchOrder no. 4102058

USB-HUB7-foldindustrialmodel220 V Order no. 410255�110 V (US type) Order no. 2245786

USB readyMeasuringInstruments

forMarCator.Dig.Indicators1075,1080,1081,1086,1087

forMillimess.DigitalComparators200020012100

MarConnect. DataProcessing

Page 6: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-6

T-Box 204 USB

MarConnect. DataProcessing

Digi-USB-1 Interface USBInterfacewithoneDigimaticinputport

Features

•PowersuppliedbytheUSBinterface

•NodriverrequiredfortheUSBinterface

•TheUSBinterfaceis recognizedasakeyboard•Terminationcharactersuchas

EnterorTABcanbesetupontheUSBinterface

•Data-keyfordata transmission

•Suppliedwith: USB-Interface

1xDigimatic-measuringinstrument-inputDimensions 20x57x33mm

Order no. 410252�

Technical Data

T-Box interfacetoconnecttomeasuringinstrumentstothekeyboardinputjackofaIBMcompatiblePC

Inputs Dimensions Order no. Remarks mm(LxWxH)

T-Box 204 USB 3xMulti-RS232CInput 130x180x40 9102519 WhenconnectingDigimatic- 1xDigimaticInput measuringinstrumentsthe standardcableoftheT-Box 205 USB 2xMulti-RS232CInput 130x180x40 4102579 manufacturercanbeused 3xDigimaticInput

Technical Data

Order no.

Foot Switch forconnectiontoT-Box 4102556Data Cable forconnectingmeasuringinstrumentsSeecableoverviewonPage11-8

Accessories

•Measuringdataisconvertedintokeyboard codes,

thereforesuitableforany softwarewithamanualinput

(e.g.MS-Excel®)•Nospecialdriversoftware

required•Independentofoperating

system(DOS,Windows, OS/2,Unix,Linux)•Measuringvaluescanbe

processedindividuallyorasagroup

•Themeasuredvaluescanbedirectlytriggeredonthe

measuringinstrumentorwiththeoptionalfootswitch

Features

•EveryMulti-RS232Cinterfaceisindividuallyadjustableviathesetupswitch

•Terminationcharacter(e.g.Enter)canbeselectedviaswitch

•ThepowerissuppliedbytheUSBinterface

•Suppliedwith: USBcable PS/2cable

Note: OnlysuitableforGerman,French,USkeyboardsorcompatible!

Page 7: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+

11-7

Send confirmation

Sendmeasuring value

DATA-Button

Confirmation,acoustic

Confirmation, optical

-OK

-Transmissionerror

Transmitter

������

MarConnect. DataProcessing

Radio Transmission RadiosystemFM1*

•Securedatatransmissionwithdialoguebetweenreceiverandtransmitter

•Acousticandopticalconfirmationofreceiptbythetransmitter

•Compacttransmitterisconnecteddirectlyontheinterfaceofthemeasuringinstrument

Features

For Measuring Instruments Order no.

MarCal 16EX,16EXC,16EXV, 16 EXt 4102�21 18EX,30EX,30EXNDigimar 814SMicromar 40EX,44EX,46EX,40EWS,40EWVMarCator 1075,1080,1081,1086,1087

MarCal 25ES,30EWD,31ES,32ES 16 ESt 4102�22Digimar 27ES,M814MarTool 106ES

Millimar C1208,C1216,C1245,S1840 RS2�2 t 2121�15Digimar CX1,CX2,817CLM

ContactMahrFederalfortransmitterstobeusedwith: µMaxµm Digimaticdevices Digimaticdatacables

Transmitter

Order no.

ReceiverforUSB FM 1 4102�20interfacesincl.driverandbasicsoftware.BasicsoftwareconsistsofasoftwarekeyboardinterfaceandsoftwaretostoremeasuredvaluesinanMS-Excel®column.

Receiver

Order no.

Mahr_EXDLL(optional) 4102�2�SoftwareforstoringmeasuringdataofseveralradiomodulesinanyExceltable.ContactMahrFederalforoptionalMSExcelbasedsoftwarethatallowfor:• Datamanipulationofupto120datainputs• FullSPCandgraphicaldisplays

Optional Software

•PowerissuppliedforthereceiverviaaUSB-InterfaceonthePC

•Upto120measuringinstrumentscanbeconnectedtothereceiver

•Radiotransmissiondistanceisfrom10mupto200m

(dependingontheenvironment)

•Radiofrequencyis433.926MHz

ThetransmissionofthemeasuredvaluetakesplaceviaactuationoftheDATAbuttononthetransmitter.Thetransmittersupplementsthemeasuredvaluewithanaddressnumber,acommunicationcontrolwordandadoublechecksum.ThespecialdatacodingandthefeedbackfromthePCtothetransmitterensuresabsolutedatasecurity.AtransmissionerrorisrecognizedbythedialoguebetweenPCandtransmitter.ThedatatransmissionisthenrepeateduptothreetimesautomaticallywithinafewmillisecondsWhenthedataissuccessfullytransmittedthegreenlightonthetransmitterflashesandashortbeepisheardconfirmingtransmission.

* Only available in North America, Canada and Mexico

Page 8: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

-

11-8

DigimaticRS232C������

MarConnect. InterfacesOverview

① OnlyavailableinNorthAmerica,CanadaandMexico② Footswitch;onlywithanadditionalUSBPort③ Cablelength18cm/7”

④ Datatransmissiononlywiththe“Data“keyor“automatic transmisison“onthemeasuringinstrument⑤ Footswitchtotransferdataonthemeasuringinstrument Millimar-Orderno.5330956/Millimar1240-Orderno.5312431

Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via

Instrument MarCom Software MarCom Software USB

FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058

16EX/EXC

16EXV

18EX

30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411

40EX,40EWS,40EWV,

46EX,44EX

1075,1080,1081,1086,1087

814S

2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021

1088

838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥

MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035

µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025

25ES

30EWD

31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510

106ES

M814

MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------

1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634

C1208,C1216

DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④

MarConnect. DataProcessing

--------

Page 9: Are you seArching for the right connections? · Millimar C1208, C1216, C1245, S1840 RS2 2 t 2121 15 Digimar CX1, CX2, 817 CLM Contact Mahr Federal for transmitters to be used with:

+

11-9

4102715 / 70246�4

41024104102�57 4102411

4�4602� 4�46020

2001025 / 22�90�7 / 4495084 ⑥

4102510

4�46021

4102��0 to 4102��4 ⑥

4102058

4102711

4102782 ③

MarConnect . Regard lessof which inter facestandardyouuse , whether ; U SB , OptoR S232oderDig imat ic , MarConnect a lwaysprov idesyouwith theopt imumconnect ion .

Connect PC to . . . Data printer MSP 2 Transmitter ① direct via USB and direct via RS2�2C and via Digi-USB 1 via T-Box FM 1 via

Instrument MarCom Software MarCom Software USB

FootSwitch 4102058+4102782③ 4102058+4102782②③ -------- 4102556 -------- 4102058

16EX/EXC

16EXV

18EX

30EX/EXN 4102357 4102410 4102411 4102411 4102321 4102411

40EX,40EWS,40EWV,

46EX,44EX

1075,1080,1081,1086,1087

814S

2000,2001,2100 4346023 4346020 4346021 4346021 -------- 4346021

1088

838EA,838EI -------- -------- 4495084⑥ 4495084⑥ ContactMahrFederal 4495084⑥

MaxµmIII (10pinoutput) -------- -------- 2239038 2239037 2239037 (6pinoutput) 2239036 2239035 2239035

µMaxµm,µMaxµmXL -------- SCB-4 2001025 2001025 ContactMahrFederal 2001025

25ES

30EWD

31ES,32ES 4102510+4102330 4102510 -------- 4102510 4102322 4102510

106ES

M814

MSP2 4102711+4102334④ 4102711④ -------- -------- -------- --------

1240,S1840,C1245, 7024634+4102331⑤ 7024634⑤ -------- 4102715 2121315⑦ 7024634

C1208,C1216

DigimarCX1,CX2,817CLM 7024634+4102333④ 7024634④ -------- -------- 2121315 7024634④

⑥ Cablelength1.5m/5ft⑦ NotforMillimar1240

Standardcablelength2m

MarConnect. DataProcessing

--------