Page 1: 3-Way or More Applications (Multi-location) Remote …...PK-93461-10-00-2A Changing the color of your Device: Your device may include color options. To change color of the face proceed

3-Way or More Applications (Multi-location)Remote Devices

Cat. No. VP00R-10, Coordinating Dimmer RemoteCat. No. VP00R-1L, Matching Dimmer Remote

Cat. No. VP0SR-10, Coordinating Switch RemoteCat. No. VP0SR-1L, Matching Switch Remote

120VAC, 60Hz INSTALLATION INSTRUCTIONS

WARNINGS AND CAUTIONS:• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,fluorescentlighting,amotor-ora

transformer-operatedappliance.• ForHi-lume® or Eco-10®(EcoSeries)electronicballastapplications,useinstructionsheetthatcomeswiththedimmerformulti-locationapplications.• Vizia+™remotesarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™orViziarf+™devicesformulti-location

switching.

WARNINGS AND CAUTIONS:• Useonlyone(1)Vizia+™dimmerinamulti-locationcircuitwithupto9coordinatingremoteswithoutLEDsorupto4matchingremoteswithLEDs.Theremote(s)

willturnthelightonatthebrightnesslevelselectedatthedimmer.• Recommendedminimumwallboxdepthis2-1/2".• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingfixture.• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.

Tools needed to install your Remote:

Slotted/PhillipsScrewdriver ElectricalTapePliers PencilCutters Ruler

INSTALLING YOUR REMOTE

NOTE:UsecheckboxeswhenStepsarecompleted.

Step 1 WARNING: TO AvOID fIRE, ShOCk, OR DEATh; TURN Off pOWER atcircuitbreakerorfuseandtestthatpowerisoffbeforewiring!

3

5

1

2

6

4

2

4

1

5

3

4-Way1. FirstTraveler–notecolor2. SecondTraveler–tagged3. Neutral4. Ground5. ThirdTraveler–notecolor6. FourthTraveler–taggedNOTE:Formatchingremotew/LEDsinstallation,thefirstTravelerbecomesLineHot.

3-Way1. Line or Load (See important instruction below)2. Neutral3. Ground4. FirstTraveler–notecolor5. SecondTraveler–notecolorNOTE:Formatchingremotew/LEDsinstallation,thefirst TravelerbecomesLineHot.

Identifying your wiring application (most common):

NOTE:Ifthewiringinthewallboxdoesnotresembleanyoftheseconfigurations,consultaqualifiedelectrician.

Step 2

IMpORTANT:

for 3-Way applications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththedimmerwallboxandremotewallbox.

for 4-Way applications,notethattheoldswitchbeingremovedwillhave4screwsplusagroundscrew.Tagthetwosamecolorinsulated wires with electrical tape.

3-Way Wiring with Matching Remote (w/LEDs) Application:NOTE: IncandescentandMagneticLowVoltageinstallations only.NOTE: Screw terminal dimmer depicted.

Step 4a

Coordinating Remote Dimmer

Bk

RDYL/RD

TerminalScrew marked

Black (Bk)

TerminalScrew marked

Red (RD)

TerminalScrew marked

Yellow/Red(YL/RD)

2

4

3

5

1Bk

RDYL/RD

2

4

3

5

1

hot (Black)

Neutral (White)

Load

DimmerCoordinating Remote (no LEDs)

YL/RD YL/RDRD

Wh

RD

BkBk

Black

not used

White

Line 120vAC, 60hz

GreenGround Green

Ground

3-Way Wiring with Coordinating Remote (no LEDs) Application:NOTE: IncandescentandMagneticLowVoltageinstallations only. NOTE: Screw terminal dimmer depicted.

Step 4b

NOTE:ThedimmermustbeinstalledinawallboxthathasaLoadconnection.Thematchingremotemustbeinstalledinawallboxwitha Line Hot connection and a Neutral connection. A Neutral wire to the matchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.Wiring Matching Remote (wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremoving

oldswitchandFirstTravelertoremoteterminalscrewmarked“BK” ortheBlackdimmerlead.

• SecondTravelerwallboxwirefromdimmertoremoteterminalscrewmarked“YL/RD”(note wire color).Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked “YL/RD”ortheYellow/Reddimmerlead.

• LineNeutralwallboxtoremoteterminalscrewmarked“WH”.

Wiring Dimmer (wall box with Load connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreen dimmer lead.

• Loadwallboxwireidentified(tagged)whenremovingoldswitchtodimmerterminalscrewmarked“RD”ortheReddimmerlead.

• FirstTravelerLineHottodimmerterminalscrewmarked“BK”ortheBlackdimmerlead.

• RemoveRedinsulatinglabelfromterminalscrewmarked“YL/RD”orYellow/Reddimmerlead.

• SecondTravelerwallboxwire(notecolorasabove)todimmerterminalscrewmarked“YL/RD”ortheYellow/Reddimmerlead.Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked“YL/RD”.

• ProceedtoStep6.

Step 4d cont’d

Cut(if necessary)

preparing and connecting wires:Thisremotecanbewiredusingsidewireterminalscrewsorthroughbackwireopenings.Chooseappropriatewirestrippingspecificationsaccordingly.

Step 3

Side Wire ConnectionSide wire terminals accept #14AWGsolidcopperwireonly.

Back Wire (either hole may be used)Backwireopeningsuse #14-12AWGsolidcopperwireonly.

5/8"(1.6 cm) Strip Gage (measure bare wire here or

use gage on back of the dimmer)

• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if necessary).

• Removeinsulationfromeachwireinthewallboxasshown.

PK-93461-10-00-2A

Changing the color of your Device:Yourdevicemayincludecoloroptions.Tochangecolorofthefaceproceedasfollows:

push in side at tab to release

Line up tabs and press in sides one at a time to attach

Bk

RDYL/RD

4

3

2

1

5

DimmerMatching RemoteTerminal

Screw markedWhite (Wh)

AdditionalNeutral Wire

Bk

RDYL/RD

4

3

1

2

5

TerminalScrew marked

Black (Bk)

TerminalScrew marked

Yellow/Red(YL/RD)

hot (Black)

Neutral (White)

Load

DimmerMatching Remote (w/LEDs)

YL/RD YL/RDRD

Wh Bk Bk

Black

White

Line 120vAC, 60hz

GreenGround

GreenGround

Step 2 cont’d

WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows:

NOTE: When using the coordinating remote without LEDs, the dimmer canbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrewor

Green dimmer lead.• LineHot(common)wallboxwireidentified(tagged)whenremoving

oldswitchtodimmerterminalscrewmarked"BK"orBlackdimmerlead.

• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orReddimmer lead (note wire color).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"RD".

• RemoveRedinsulatinglabelfromterminalscrewmarked "YL/RD"orYellow/Reddimmerlead.

• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"orYellow/Reddimmerlead(note wire color).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".

WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows:

NOTE:Maximumwirelengthfromdimmertolastremoteis 300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchto

terminalscrewmarked"BK".• FirstTravelerwallboxwire(note color as above) to terminal screw

marked"RD".Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"RD"orReddimmerlead.

• SecondTravelerwallboxwire(note color as above) to terminal screwmarked"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"YL/RD"orYellow/Reddimmer lead.

• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelaffixed.

NOTE:Ifinsulatinglabelisnotaffixedtoterminalscrewmarked"WH",useelectricaltapetocover.

• proceed to Step 6.

3-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application:NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeed and Electronic Switch installations only. NOTE: Dimmer is depicted.

Step 4c

4

3

5

ControlMatching Remote

Black

Green

White

Red

Yellow/Red

1

2

TerminalScrew marked

White (WH)AdditionalNeutral Wire

BK

RDYL/RD

4

3

1

2

5

TerminalScrew marked

Black (BK)

TerminalScrew marked

Yellow/Red(YL/RD)

Hot (Black)

Neutral (White)

ControlcMat hing Remote (w/LEDs)

YL/RD Yellow/RedRed

WH BK Black

Black

White

LoadLine

120VAC, 60Hz

White

GreenGround

GreenGround

NOTE:ThecontrolmustbeinstalledinawallboxthathasaLoadconnection.Thematchingremotemustbeinstalledinawallboxwitha Line Hot connection and a Neutral connection. A Neutral wire to the matchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed300ft(90m).WIRING MATChING REMOTE (wall box with Line hot connection):Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremoving

oldswitchandFirstTravelertoterminalscrewmarked"BK"orBlackdimmer lead.

• SecondTravelerwallboxwirefromcontroltoremoteterminalscrewmarked"YL/RD"(note wire color).Thistravelerfromtheremotemustgototerminalscrewmarked"YL/RD"orYellow/Redcontrollead.

• LineNeutralwallboxtoremoteterminalscrewmarked"WH".

WIRING DIMMER (wall box with Load connection):Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreen control lead.

• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminalscrewmarked"RD"orRed control lead.

• FirstTravelerLineHottoterminalscrewmarked"BK"orBlackcontrol lead.

• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Redcontrollead.

• SecondTravelerwallboxwire(note color as above) to terminal screwmarked"YL/RD"orYellow/Redcontrollead.Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".

• Lineneutralwallboxwiretoterminalscrewmarked"WH"orWhite control lead.

• proceed to Step 6.

BK

RDYL/RD

ControlCoordinating Remote

3

1

3

4

5

Black

White

Green

Red

Yellow/Red

21

4

TerminalScrew marked

White (WH)

TerminalScrew marked

Yellow/Red(YL/RD)

2

5

Hot (Black)

Neutral (White)

ControlrCoo dinating Remote (no LEDs)

YL/RD YL/RDRD

White

Red

Black

Black

BKWH

White

LoadLine

120VAC, 60Hznot used

not used

GreenGround

GreenGround

3-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedandElectronicSwitchinstallationsonly.NOTE: Dimmer is depicted.

Step 4d

WIRING CONTROL: Connect wires per WIRING DIAGRAM as follows:

NOTE:ThecontrolmustbeinstalledinawallboxthathasaLineHotConnection.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrewor

Green control lead.• LineHot(common)wallboxwireidentified(tagged)whenremoving

oldswitchtoterminalscrewmarked"BK"orBlackcontrollead.• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRed

control lead (note wire color).• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"

orYellow/Redcontrollead.• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"

orYellow/Redcontrollead(note wire color).Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".

• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrol lead.

WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows:

NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenbothscrews.NOTE:Maximumwirelengthfromcontroltolastremoteis 300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitch

toFirstTraveler(note color as above).• SecondTravelerwallboxwire(note color as above) to terminal

screwmarked"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewmarked"YL/RD"orYellow/Redcontrollead.

• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".

• LineNeutralwallboxwiretoterminalscrewmarked"WH".• proceed to Step 6.

4-Way Wiring with Matching Remote (w/LEDs) Application:NOTE:IncandescentandMagneticLowVoltageinstallations only.NOTE: Screw terminal dimmer depicted.

Step 5a

Bk

RDYL/RD

Bk

RDYL/RD

4

3

2

1

5

Matching Remote(3-Way Wall box from Step 2)

Matching Remote(4-Way Wall box from Step 2)

Dimmer(3-Way Wall box from Step 2)

4

3

5

AdditionalNeutral Wire

TerminalScrew marked

Black (Bk)

TerminalScrew marked

White (Wh)

6

2

1

TerminalScrew marked

White (Wh)AdditionalNeutral Wire

Bk

RDYL/RD

4

3

1

2

5

TerminalScrew marked

Black (Bk)

TerminalScrew marked

Yellow/Red(YL/RD)

TerminalScrew marked

Yellow/Red(YL/RD)

hot (Black)

Neutral (White)

Load

DimmerMatching Remote

(w/LEDs)Matching Remote

(w/LEDs)

YL/RDYL/RD YL/RDRD

WhWh BkBk Bk

Black

White

Line 120vAC, 60hz

GreenGround

GreenGround

GreenGround

NOTE:ThedimmermustbeinstalledinawallboxthathasaLoadconnection.Thematchingremotemustbeinstalledinawallboxwith a Line Hot connection and a Neutral connection. A Neutral wire tothematchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).WIRING MATChING REMOTE (4-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• FirstTravelerandThirdTravelerwallboxwirefromdimmerin

the3-wayboxtoremoteterminalscrewmarked"BK"inthe 4-waybox,andtotheterminalscrewmarked"BK"oftheremainingremoteinthe3-waybox.

• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwirefromdimmerinthe3-wayboxtoremoteterminalscrewmarked"YL/RD"inthe4-waybox,andtotheterminalscrewmarked"YL/RD"oftheremainingremoteinthe3-waybox(note wire colors).Thistravelerfromtheremotesmustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmer lead.

• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".

WIRING MATChING REMOTE (3-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)when

removingoldswitchandFirstTravelerdimmerterminalscrewmarked"BK"ortheBlackdimmerlead.

• SecondTravelerwallboxwirefromdimmertoremoteterminalscrewmarked"YL/RD"(note wire color as above).Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmerlead.

• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".

Page 2: 3-Way or More Applications (Multi-location) Remote …...PK-93461-10-00-2A Changing the color of your Device: Your device may include color options. To change color of the face proceed

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenefitofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforfiveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchfiveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandfitnessforaparticularpurpose,islimitedtofiveyears. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.

NOTE:Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.• Restorepoweratcircuitbreakerorfuse.• Seeapplicableoperationsectiontoensuredimmerorswitchisfunctioningproperly.

If lights do not turn ON, refer to the TROUBLEShOOTING section.•

for additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.leviton.com

CoveredbyoneormoreUS&ForeignPatentsandpatentspendingCopyright©2007LevitonManufacturingCo.,Inc.

AllRightsIncludingTradeDressRightsReservedEco-10™(EcoSeries)isatrademarkandHi-lume®isaregisteredtrademarkof

LutronElectronicsInc.

PK-93461-10-00-2A

Restore power:Restorepoweratcircuitbreakerorfuse.Installation is complete.

Step 8

Dimmer Remote Mounting:TURN Off pOWER AT CIRCUIT BREAkER OR fUSE.

Step 7

Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.

vp00R Dimmer Remote Operation (Device may be unlighted):

NOTE:ThelightswillturnONatbrightnesssetondimmer’sDIM/BRIGHTbar.Thelightingcanbeswitchedfromeitherthedimmerortheremotelocation.

OpERATION

CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.

• Lights flickering -Lamphasabadconnection. -Wiresnotsecuredfirmlyunderterminalscrewsofdimmerand/orremote.• Light does not turn ON and Locator LED does not turn ON -Circuitbreakerorfusehastripped. -Lampisburnedout. - Lamp Neutral connection is not wired.• Intermittent dimmer operation -Minimumloadisunder40W.• Remote does not operate lights -Ensurethattotalwirelengthdoesnotexceed300ft(90m). -EnsurethatonlyCoordinatingRemotesareusedwithViziarf+™devices

TROUBLEShOOTING

WIRING DIMMER (3-Way wall box with Load connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmerlead.

• Loadwallboxwireidentified(tagged)whenremovingoldswitchtodimmerterminalscrewmarked"RD"ortheReddimmerlead.

• FirstTravelerLineHottodimmerterminalscrewmarked"BK"ortheBlackdimmerlead.

• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"ortheYellow/Red dimmer lead.

• SecondTravelerwallboxwire(note color as above) to dimmer terminal screw marked"YL/RD"ortheYellow/Reddimmerlead.Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".

• proceed to Step 6.

Step 5a cont’d 4-Way Wiring with Matching Remote (w/LEDs) Application:

Bk

RDYL/RD

3

TerminalScrew marked

Red (RD)

TerminalScrew marked

Yellow/Red(YL/RD)

Coordinating Remote(3-Way Wall box from Step 2)

Coordinating Remote(4-Way Box from Step 2)

Dimmer(3-Way Wall Box from Step 2)

62

15

4

Bk

RDYL/RD

TerminalScrew marked

Black (Bk)

TerminalScrew marked

Red (RD)

TerminalScrew marked

Yellow/Red(YL/RD)

2

4

3

5

1 Bk

RDYL/RD

2

4

3

5

1

hot (Black)

Neutral (White)

Load

DimmerCoordinating Remote

(no LEDs)Coordinating Remote

(no LEDs)

YL/RDYL/RD YL/RDRDRD

WhWh

RD

BkBkBk

Black

not used

White

Line 120vAC, 60hz

not used not used

GreenGround

GreenGround

GreenGround

Step 5b 4-Way Wiring with Coordinating Remote (no LEDs) Application:NOTE:IncandescentandMagneticLowVoltageinstallationsonly. NOTE: Screw terminal dimmer depicted.

WIRING COORDINATING REMOTE (4-Way box):Connect wires per WIRING DIAGRAM as follows:NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• FirstTravelerandThirdTravelerwallboxwire(note wire colors) to terminal

screwmarked"RD".Thesetravelersfromtheremoteinthe4-wayboxmustgototheterminalscrewonthedimmermarked"RD"orReddimmerlead,andtotheterminalscrewmarked"RD"oftheremainingremoteinthe3-waybox.

• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwire(note wire colors)toterminalscrewmarked"YL/RD".Thesetravelersfromtheremoteinthe4-wayboxmustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmerlead,andtotheterminalscrewmarked"YL/RD"oftheremainingremoteinthe3-waybox.

• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelaffixed. NOTE:Ifinsulatinglabelisnotaffixedtoterminalscrewmarked"WH",use

electricaltapetocover.Remoteterminalscrewmarked"BK"isnotused.Useelectricaltapetocover.

WIRING DIMMER (3-Way box):Connect wires per WIRING DIAGRAM as follows:NOTE:WhenusingthecoordinatingremotewithoutLEDs,thedimmercanbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed 300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmer

lead.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchto

dimmerterminalscrewmarked"BK"orBlackdimmerlead.• FirstTravelerwallboxwiretodimmerterminalscrewmarked"RD"orReddimmer

lead (note wire color as above).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"RD".

• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Reddimmer lead.

• SecondTravelerwallboxwiretodimmerterminalscrewmarked"YL/RD"orYellow/Red dimmer lead (note wire color as above).Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".

WIRING COORDINATING REMOTE (3-Way box):Connect wires per WIRING DIAGRAM as follows:NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminalscrew

marked"BK".• FirstTravelerwallboxwire(note color as above)toterminalscrewmarked"RD".

Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"RD"ortheReddimmerlead.

• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked"YL/RD"ortheYellow/Reddimmerlead.

• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulationlabelaffixed. NOTE:Ifinsulatinglabelisnotaffixedtoterminalscrewmarked"WH",use

electricaltapetocover.• proceed to Step 6.

4

3

5

Black

Green

White

Red

Yellow/Red

1

2

Control(3-Way Wall Box from Step 2)

BK

RDYL/RD

Matching Remote(3-Way Wall box from Step 2)

Matching Remote(4-Way Wall box from Step 2)

4

3

5

AdditionalNeutral Wire

TerminalScrew marked

Black (BK)

TerminalScrew marked

White (WH)

6

2

1

TerminalScrew marked

White (WH)AdditionalNeutral Wire

BK

RDYL/RD

4

3

1

2

5

TerminalScrew marked

Black (BK)

TerminalScrew marked

Yellow/Red(YL/RD)

TerminalScrew marked

Yellow/Red(YL/RD)

Hot (Black)

Neutral (White)

ControlMatching Remote

(w/LEDs)

Matching Remote(w/LEDs)

YL/RDYL/RD Yellow/RedRed

WH WhiteWH BKBK Black

Line 120VAC, 60Hz

Black

White

Load

GreenGround

GreenGround Green

Ground

4-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application:NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedandElectronicSwitch installations only.NOTE: Dimmer is depicted.

Step 5c

NOTE:ThecontrolmustbeinstalledinawallboxthathasaLoadconnection.ThematchingremotemustbeinstalledinawallboxwithaLineHotconnectionandaNeutralconnection.ANeutralwiretothematchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed 300ft(90m).

WIRING MATChING REMOTE (4-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• FirstTravelerandThirdTravelerwallboxwiretoremoteterminalscrewmarked"BK"

in4-waybox,andtoterminalscrewmarked"BK"oftheremainingremotein3-waybox.

• SecondTraveler(tagged)andFourthTraveler(tagged)wallboxwirefromcontrolin3-wayboxtoremoteterminalscrewmarked"YL/RD"in4-wayboxandtoterminalscrewmarked"YL/RD"oftheremainingremotein3-waybox(note wire colors).Thistravelerfromtheremotesmustgototheterminalscrewmarked"YL/RD"or Yellow/Redcontrollead.

• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".

WIRING MATChING REMOTE (3-Way wall box with Line hot connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchand

FirstTravelerwallboxwiretocontrolterminalscrewmarked"BK"orBlackdimmerlead.

• SecondTravelerwallboxwirefromcontroltoremoteterminalscrewmarked"YL/RD"(note wire color as above).Thistravelerfromtheremotemustgototheterminalscrewmarked"YL/RD"orYellow/Reddimmerlead.

• LineNeutralwallboxwiretoremoteterminalscrewmarked"WH".

WIRING CONTROL (3-Way wall box with Load connection): Connect wires per WIRING DIAGRAM as follows:

• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreendimmerlead.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminalscrew

marked"RD"orRedcontrollead.• FirstTravelerLineHottoterminalscrewmarked"BK"orBlackcontrollead.• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Red

control lead.• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked

"YL/RD"orYellow/Redcontrollead.Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".

• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrollead.• proceed to Step 6.

4-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:

NOTE:ElectronicLowVoltage,Mark10™,QuietFanSpeedandElectronic Switch installations only. NOTE: Dimmer is depicted.

Step 5d

WIRING CONTROL (3-Way box): Connect wires per WIRING DIAGRAM as follows:

NOTE:ThecontrolmustbeinstalledinawallboxthathasaLineHotconnection.NOTE:Maximumwirelengthfromcontroltoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscreworGreencontrollead.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchto

terminalscrewmarked"BK"orBlackcontrollead.• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRedcontrollead(note

wire color as above). • RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"orYellow/Red

control lead.• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"orYellow/Red

control lead (note wire color as above).Thistravelerfromthecontrolmustgototheterminalscrewontheremotemarked"YL/RD".

• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhitecontrollead.

WIRING COORDINATING REMOTE (3-Way box): Connect wires per WIRING DIAGRAM as follows:

NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenbothscrews.NOTE:Maximumwirelengthfromcontroltolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoFirstTraveler(note

color as above).• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked

"YL/RD".Thistravelerfromtheremotemustgototheterminalscrewmarked"YL/RD"orYellow/Redcontrollead.

• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".• LineNeutralwallboxwiretoterminalscrewmarked"WH".• proceed to Step 6.

BK

RDYL/RD

3

5

1

2

3

4

5

Black

White

Green

Red

Yellow/Red

21

14

4

3

52

TerminalScrew marked

White (WH)

TerminalScrew marked

White (WH)

TerminalScrew marked

Yellow/Red(YL/RD)

TerminalScrew marked

Black (BK)

TerminalScrew marked

Yellow/Red(YL/RD)

TerminalScrew marked

Black (BK)

Coordinating Remote(3-Way Wall box from Step 2)

Coordinating Remote(4-Way Box from Step 2)

Control(3-Way Wall Box from Step 2)

6

BK

RDYL/RD

Hot (Black)

Neutral (White)

ControlCoordinating Remote(no LEDs)

Coordinating Remote(no LEDs)

YL/RDYL/RDYL/RD RD

White

Red

Black

Black

BKWHWH

White

Line 120VAC, 60Hz

RDnot used

not used not used

not used

BK

Load

GreenGround

GreenGround

GreenGround

WIRING COORDINATING REMOTE (4-Way box): Connect wires per WIRING DIAGRAM as follows:

NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenbothscrews.NOTE:Maximumwirelengthfromdimmertolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• ConnectFirstTravelerwallboxwiretoThirdTravelerwallboxwire(note wire colors)

toterminalscrewmarked"RD"ofremotein4-waybox,andtoterminalscrewmarked"RD"oftheremainingremotein3-waybox.

• ConnectSecondTravelerandFourthTravelerwallboxwire(note wire colors) to terminalscrewmarked"YL/RD"ofremotein4-waybox,andtoterminalscrewmarked"YL/RD"oftheremainingremotein3-waybox.

Thistravelerfromtheremotesmustgototheterminalscrewmarked"YL/RD"orYellow/Redcontrollead.

• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".• LineNeutralwallboxwiretoterminalscrewmarked"WH".

Step 5d cont’d

Testing your Remote prior to completely mounting in wall box:

Step 6

push pad (Default settings)Turn ON from Off position:Tap–LightsturnONtopresetlevel.PressandHold–LightsturnONtofullbright.Turn Off from ON position:Tap–LightsturnOFF.DIM/BRIGhT BarBRIGhTEN:PressrighthalfofDIM/BRIGHTBar–Lightsbrightentodesiredlevel.DIM:PresslefthalfofDIM/BRIGHTBar–Lightsdimtodesiredlevel.Ifyoucontinuetohold,thelightswillDIMtominimumlevelandthenturnOFF.Intheeventofpoweroutageorinterruptionthelightswillresettothelastlevelwhenpowerisrestored.

DIM/BRIGhT Bar

push pad Locator Light

LED Brightness

Display

vp0SR Switch Remote Operation (Device may be unlighted):Thelightingcanbeswitchedfromeitherthedimmerortheremotelocation.

push pad (Default settings)Turn ON from Off position:Tap–LightsturnONtopresetlevel.

Turn Off from ON position: Tap–LightsturnOFF.

Intheeventofpoweroutageorinterruption the lights will reset to the last levelwhenpowerisrestored.

push pad

LocatorLight

ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe

receiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.

fCC COMpLIANCE STATEMENT

• Positionallwirestoprovideroominoutletwallboxfordevice.

• Ensurethattheword"TOP"isfacinguponthedevicestrap.

• Partiallyscrewinmountingscrewsinwallboxmountinghole.

vp00R-1L ADvANCED pROGRAMMING fEATURES fOR USE WITh vIZIA Rf +™ ONLY

Definition of A ModesA) LEDOptions:SetssingleLED(default)orLEDBartodisplaytheloadstatus.

program Mode ATo enter program Mode A:Press and hold the Push Pad and then the righthalfoftheDIM/BRIGHTBar(^)for5secondsuntilallLEDsblink.UponreleasingthePushPadLocatorLEDwillblinkoncepersecondtoindicateProgram Mode A, LED Options.TochangetheLED Options settings, release thePushPad.ThissettingwillautomaticallybesavedandthedevicewillexitProgramming Mode.

LED Options LED Brightness/fan Speed Display

Default Single LED

Firsttoggle LEDBar


Recommended