Transcript
Page 1: Notes · 2019. 11. 22. · 1,150 16,029 16,558 15,045 11,358 3,228 satellite centres, tallaght hospital - existing contiguous elevations 1:200 john donnelly 10/06/2015 neil orpwood

National PaediatricHospital Project

13130.06 /

National PaediatricHospital DevelopmentBoard

NotesCheck all dimensions on site. Do not scale from this drawingReport any discrepancies and omissions to HLM ArchitectsThis Drawing is Copyright ©

Project

Client

Title

Drawing No. Revision

Scale @ A1 Drawn

Date Checked

M 20 40 60 801

0.51 2 3

0.5

1:12501:50/1:20

Revisions

TH-HLM-A-DR-XX-Z1-1120

106,606

118,529

115,500

121,928

118,529

12,60

0

8,100

4,106

2,306

3,399

3,429

6,000

3,429

102,500

115,500

118,529

115,100

105,623

105,200

103,400

12,60

03,0

29

5,248

9,477

3,445

102,500

106,606107,000

115,500

118,529

2,306

5,596

4,900

3,555

3,795

2,700

1,440

115,100

113,600

111,800

110,300

108,500

107,000

12,60

0

4,106

2,713

1,312

3,795

3,795

3,960

400

1,879

1,150

16,02

9

16,558 15,045 11,358 3,228

SATELLITE CENTRES,TALLAGHT HOSPITAL -EXISTING CONTIGUOUSELEVATIONS

1:200 John Donnelly

Neil Orpwood10/06/2015

P5

Rev Description Drn ChkDate

PRELIMINARY PLANNING ISSUEP1 JD NO03/07/15

ISSUE FOR PLANNINGP2 RN NO15/07/15

AMENDMENTS MADE FOLLOWINGCLIENT COMMENTS

P3 RN NO24/07/15

Revisions as per Client commentP4 JT JD29/07/15

Issue to PlanningP5 JT NO31/07/15

DESIGN/SKETCH DESIGNUnless stated otherwise, the designs shown are subject to detailed site survey,investigations, and legal definition, the CDM Regulations, and the comments and / orapproval of the various relevant Local Authority Officers, Statutory Undertakers, Fire Officers,Engineers and the like. They are copyright, project specific and confidential and no part is tobe used or copied in any way without the express prior consent of HLM Architects.

PHOTOCOPIED/SCANNED INFORMATIONNB This drawing is based on photocopied / scanned information liable to distortion in scale.

AREA CALCULATIONSNB The areas shown are approximate only and have been measured off preliminarydrawings as the likely areas at the current state of design using the stated option from theCode of Measuring Practice, 4th edition. RICS / ISVA. These may be affected by futuredesign development and construction tolerances, or the result of surveys for existingbuildings. Take account of these factors before planning any financial or propertydevelopment purpose or strategy and seek confirmation of latest areas before decisionmaking.

3RD-PARTY INFORMATIONNB This drawing includes information provided by independent surveyors and / orconsultants, to whom all queries shall be made. HLM Architects can accept no liability for itscontent or accuracy.

SOUTH FACING ELEVATION 1:200

NORTH FACING ELEVATION 1:200

EAST FACING ELEVATION 1:200