LV & MV Circuit Breaker
Full Line up
7/22/2019 04LV MV(eng)24P
3/24
HYUNDAI Circuit Breaker is one of the most reliable and
sophisticated products, which realizes the optimum design
through electric and kinetic analysis.
LV & MV Circuit Breaker,Contactor & Overload Relay
www.hyundai-elec.com
|Contents
04 _ Molded Case Circuit Breaker
10_ Miniature Series
12 _ Contactor & Overload Relay
18 _ Air Circuit Breaker20_ Vacuum Contactor
22 _ Vacuum Circuit Breaker
7/22/2019 04LV MV(eng)24P
4/24
Molded Case Circuit BreakerOptimum design provides easy-to-use customer installation, while offering versatility and high performance tomatch today's demand for a reliable and cost-effective product, which is easy to maintain.
Qualied Standard & Approval
Standard IEC 60947-2 NEMA AB-1 KS C8321
Approval ISO 18001, 14001, 9001 CE (Community European / TU..V Rheinland) KEMA
KS
TSE
GOST-R
CCC
KR, ABS, BV, NK, RINA, LR, GL
04 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
U-Series
ADVANCED TECHNOLOGYin size
CUSTOMIZED CHARACTERISTICin range
POWERFUL CAPABILITYin specication
UAB type
UCB type
UPB type
Line side terminal
Rated frequency
Utilization category
Rated current
Standard
Trip unit
Trip button
Load side terminalApprovals and certicates
Suitability of isolation
Model nameUPB : Type
250 : Ampere frame size
X : Recognition code for order
Ampere frame size
Main characterisiticsUi : Rated insulation voltage
Uimp : Rated impulsewithstand voltage
Ue : Rated operational voltage
Icu : Rated ultimateshort-circuit breakingcapacity
Ics : Rated serviceshort-circuit breakingcapacity
7/22/2019 04LV MV(eng)24P
5/24
05www.hyundai-elec.com
VCBVCACBMCMINIATUREMCCB
UAB type / 30-100AF
UCB type / 50-1600AF
Ampereframe
ModelNumberof poles
Rated current (A)Breaking capacity [Icu] (kA r.m.s.) Trip mechanism & Characteristics Dimensions (mm)
AC220VAC240V
AC380VAC415V
AC440VAC460V
AC600VAC660V
Hydraulicmagnetic
Thermal magneticWidth Height DepthFixed Adjustable
30UAB30C 2, 3 3,5,10,15,20,30 10 7.5/5 5 2.5 - -
50/75 130 60UAB30R 2, 3 5,10,15,20,30 25 14/10 10 5 - -
50
UAB50C 2, 3, 4 5,10,15,20,30,40,50 10 7.5/5 5 2.5 - -
50/75/100 130 60
UAB50R 2, 3, 4 5,10,15,20,30,40,50 25 14/10 10 5 - -
UAB50S 2, 3, 4 15,16,20,25,30,32,40,50 42 25 21 7.5 - 1)
UAB50H 2, 3, 4 15,16,20,25,30,32,40,50 50 30 25 10 - 1)
60UAB60C 2, 3, 4 5,10,15,20,30,40,50,60 10 7.5/5 5 2.5 - -
UAB60R 2, 3, 4 5,10,15,20,30,40,50,60 25 14/10 10 5 - -
100
UAB100C 2, 3, 4 5,10,15,20,30,40,50,60,75,100 25 14/10 10 5 - -
UAB100R 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100 42 25 21 7.5 - 1)
UAB100S 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100 50 30 25 10 - 1)
Ampereframe
ModelNumberof poles
Rated current (A)Breaking capacity [Icu] (kA r.m.s.) Trip mechanism & Characteristics Dimensions (mm)
AC220VAC240V
AC380VAC415V
AC440VAC460V
AC600VAC660V
Thermal magneticElectronic Width Height DepthFixed Adjustable
50
UCB50R 2, 3, 4 15,20,30,40,50 50 30/25 25 10 - - 60/90/120 155 60
UCB50H 2, 3, 4 15,16,20,25,30,32,40,50 85 42 42 20 -90/90/120 155 60
UCB50L 2, 3, 4 15,16,20,25,30,32,40,50 100 50 50 25 -
125
UCB100R 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125 50 30/25 25 10 -
60/90/120 155 60UCB100S 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125 65 42/36 35 18 -
UCB100H 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125 85 42 42 20 -90/90/120 155 60
UCB100L 2, 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,125 100 50 50 25 -
160UCB160H 2, 3, 4 100,125,160 85 42 42 20 -
105/105/140 165 60UCB160L 2, 3, 4 100,125,160 100 50 50 25 -
250
UCB250R 2, 3, 4 125,150,160,175,200,225,250 35 25/18 18 7.5 -
105/105/140 164 60UCB250S 2, 3, 4 125,150,160,175,200,225,250 50 35/25 25 10 -
UCB250N 2, 3, 4 125,150,160,175,200,225,250 65 42/36 35 18 -
UCB250H 2, 3, 4 125,150,160,175,200,225,250 85 42 42 20 -105/105/140 165 60
UCB250L 2, 3, 4 125,150,160,175,200,225,250 100 50 50 25 -
400
UCB400R 2, 3, 4 250,300,320,350,400 35 30 25 18 -
140/140/185 257 110
UCB400S 2, 3, 4 250,300,320,350,400 50 42 35 22 -
UCB400H 2, 3, 4 250,300,320,350,400 85 65 50 25 -
UCB400L 2, 3, 4 250,300,320,350,400 125 100 85 30 -
630
UCB630R 2, 3, 4 500,630 50 45 35 22 -
210/210/280 280 110
UCB630S 2, 3, 4 500,630 100 65 50 25 -
UCB630H 2, 3, 4 500,630 100 85 65 35 -
UCB630L 2, 3, 4 500,630 125 100 85 35 -
800
UCB800R 2, 3, 4 700,800 50 45 35 25 -
UCB800S 2, 3, 4 700,800 100 65 50 25 -
UCB800H 2, 3, 4 700,800 100 85 65 35 -
UCB800L 2, 3, 4 700,800 125 100 85 35 -
1000UCB1000S 3, 4 505-1000 100 100 75 40 - - 210/280 370 110
UCB1000L 3, 4 505-1000 150 130 100 60 - - 210/280 370 200
1250UCB1250S 3, 4 630-1250 100 100 75 40 - - 210/280 370 110
UCB1250L 3, 4 630-1250 150 130 100 60 - - 210/280 370 200
1600 UCB1600S 3 640-1600 100 65 45 25 - - 210 371 151
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 1)Not applicable to 2P breaker.
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 2P breaker has same dimension with 3P breaker, but the middle pole is removed.
7/22/2019 04LV MV(eng)24P
6/24
06 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
Motor protection / UPB type 125-250AF
Q-class (for nuclear power plant application) /HBL type 100-225AF
UPB type / 125-630AF
- The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
1)Rated current of electronic types are as followings; UPB100: 50-125A UPB160: 63-160A UPB250: 100-250A
The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue.
Ampereframe
ModelNumberof poles
Rated current (A)Breaking capacity [Icu] (kA r.m.s.) Trip mechanism & Characteristics Dimensions (mm)
AC220VAC240V
AC380VAC415V
AC440VAC460V
AC660VAC690V
Thermal magneticElectronic Width Height DepthFixed Adjustable
125
UPB100S 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,1251) 100 85 65 10
105/140 165 86.5
UPB100H 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,1251) 130 100 85 10
UPB100L 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,1251) 150 130 100 25
UPB100X 3, 4 15,16,20,25,30,32,40,50,60,63,75,80,100,1251) 200 150 150 25
160
UPB160S 3, 4 100,125,1601) 100 85 65 10
UPB160H 3, 4 100,125,1601) 130 100 85 10
UPB160L 3, 4 100,125,1601) 150 130 100 25
UPB160X 3, 4 100,125,1601) 200 150 150 25
250
UPB250S 3, 4 125,150,160,175,200,225,2501) 100 85 65 10
UPB250H 3, 4 125,150,160,175,200,225,2501)
130 100 85 10 UPB250L 3, 4 125,150,160,175,200,225,2501) 150 130 100 25
UPB250X 3, 4 125,150,160,175,200,225,2501) 200 150 150 25
400
UPB400S 3, 4 200-400 100 85 65 10 - -
140/185 255 117
UPB400H 3, 4 200-400 130 100 85 10 - -
UPB400L 3, 4 200-400 150 130 100 25 - -
UPB400X 3, 4 200-400 200 150 150 25 - -
630
UPB630S 3, 4 320-630 100 85 65 10 - -
UPB630H 3, 4 320-630 130 100 85 10 - -
UPB630L 3, 4 320-630 150 130 100 25 - -
UPB630X 3, 4 320-630 200 150 150 25 - -
Ampereframe
ModelNumberof poles
Rated current (A)Breaking capacity [Icu] (kA r.m.s.) Dimensions (mm)
AC220VAC240V
AC380VAC415V
AC440VAC460V
AC660VAC690V Width Height Depth
125UPB100H 3 2.5,3.2,6.3,12.5,20,32,50,63,80,100 130 100 85 10
105 165 86.5UPB100L 3 2.5,3.2,6.3,12.5,20,32,50,63,80,100 150 130 100 25
250UPB250H 3 125,150,175,200,225 130 100 85 10
UPB250L 3 125,150,175,200,225 150 130 100 25
Ampereframe
ModelNumberof poles
Rated current (A)Breaking capacity [Icu] (kA r.m.s.) Characteristics Dimensions (mm)
AC220VAC240V
AC380VAC415V
AC440VAC460V
AC480VAC500V
AC660VAC690V E1 class
Motorprotection Width Height Depth
100
HBL103U 3 15,20,30,40,50,60,75,100 200 150 100 85 25 - -
105 165 86.5
HBL103UQ 3 15,20,30,40,50,60,75,100 200 150 100 85 25 -
HBL103UM 3 2.5,3.2,6.3,12.5,20,32,50,63,80,100 200 150 100 85 25 -
HBL103UMQ 3 2.5,3.2,6.3,12.5,20,32,50,63,80,100 200 150 100 85 25
225
HBL203U 3 125,150,175,200,225 200 150 100 85 25 - -
HBL203UQ 3 125,150,175,200,225 200 150 100 85 25 -
HBL203UM 3 125,150,175,200,225 200 150 100 85 25 -
HBL203UMQ 3 125,150,175,200,225 200 150 100 85 25
7/22/2019 04LV MV(eng)24P
7/24
07www.hyundai-elec.com
Miniature type / 30-100AF
Switch disconnector / 50-1250AFUAB100S UCB250L UPB400X
VCBVCACBMCMINIATUREMCCB
TypeAmpereframe
Model Numberof poles
Rated current (A)ated residualcurrent [In]
(mA) for ELCB
Breaking capacity [Icu] (kA r.m.s.) Dimensions (mm)
AC220VAC240V
AC380VAC415V
AC440VAC460V Width Height Depth
Molded casecircuit breaker
Earth leakagecircuit breaker
UMBUMG
30
UMB30R UMG30R 2 15,20,30 15, 30 2.5 - - 33 70 57
UMB30S UMG30S 2 15,20,30 15, 30 5 - -
35 80 60UMB30H UMG30H 2 15,20,30 15, 30 10 - -
50UMB50S UMG50S 2 15,20,30,40,50 15, 30 5 - -
UMB50H UMG50H 2 15,20,30,40,50 15, 30 10 - -
UDBUDG
30
UDB30S UDG30S 2, 3 3,5,10,15,20,30 15, 30 5 2.5 2.5
50/75 96 60
UDB30H UDG30H 2, 35,10
15, 305 2.5 2.5
15,20,30 10 5 5
50
UDB50S UDG50S 2, 3 5,10,15,20,30,40,50 15, 30 5 2.5 2.5
UDB50H UDG50H 2, 35,10
15, 305 2.5 2.5
15,20,30,40,50 10 5 5
100UDB100S UDG100S 2, 3 15,20,30,40,50,60,75,100 30, 100 5 2.5 2.5
75/75 96 60UDB100H UDG100H 2, 3 15,20,30,40,50,60,75,100 30, 100 10 5 5
TypeAmpereframe
ModelNumberof poles
Ratedcurrent (A)
Dimensions (mm)
Width Height Depth
UCD
50 UCD50H 3 50
90 155 60100 UCD100S 3 100
125 UCD100H 3 125
160 UCD160H 3 160 105 165 60
250UCD250S 3 250 105 164 60
UCD250H 3 250 105 165 60
400 UCD400S 3 400 140 257 110
630 UCD630S 3 630210 280 110
800 UCD800S 3 800
1000 UCD1000S 3 1000210 370 110
1250 UCD1250S 3 1250
TypeAmpereframe
ModelNumberof poles
Ratedcurrent (A)
Dimensions (mm)
Width Height Depth
UAD50 UAD50C 3 50
75 130 60UAD50S 3 50
100 UAD100R 3 100
UPD
125 UPD100S 3 125
105 165 86.5160 UPD160S 3 160
250 UPD250S 3 250
400 UPD400S 3 400140 255 117
630 UPD630S 3 630
- KS certied products. English nameplate and 50Hz marking are not available. - The breaking capacity highlighted with blue and thick type is standard nominal value for each model in this catalogue. 2P breaker has same dimension with 3P breaker, but the middle pole is removed.
7/22/2019 04LV MV(eng)24P
8/24
08 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
The applicable accessories of each MCCB are not same as above. For exact application to each MCCB, please reter to product catalogue.
Accessories
Plug-in mounting base [ TDM ]
DIN-rail adapter [ DRA ]
Interpole barrier[ TQQ ]
Interpole barrier[ TQQ ]
Auxiliary switch[ AUX ]
Trip alarm switch [ ALT ]
Terminal cover[ TCF ]
Terminal cover[ TCF ]
Shunt trip [ SHT ]
Cage terminal block[ CTB ]
Cage terminal block[ CTB ]Surface type operating handle [ TFG ]
Extended type operating handle [ TFH ]
Motor operator [ MOT ]
Under voltage trip [ UVT ]
7/22/2019 04LV MV(eng)24P
9/24
09www.hyundai-elec.com
HiBS803NE
HiBL203NE
HiBS103
1)2 pole has same dimension with 3 pole, but middle pole is removed. 2)250A for HiBL225NT and HiBL225NE is non-standard and available on special request. 3)630A for HiBS600NE, HiBL600NE and HiBX600NE is non-standard and available on special request.
Hi-Series
Fixed thermal type
Adjustable thermal type
Electronic type
VCBVCACBMCMINIATUREMCCB
Frame ModelNumber of
polesRated current (A)
Breaking capacity [Icu] (kA r.m.s.)
220/240V 380/415V 600V
30HiBS30 2, 3 3, 5, 10, 15, 20, 30 10 7.5/5 2.5HiBH30 2, 3 5, 10, 15, 20, 30 25 14/10 5
50HiBE50 2, 3, 4 5, 10, 15, 20, 30, 40, 50 10 7.5/5 2.5HiBS50 2, 3, 4 5, 10, 15, 20, 30, 40, 50 25 14/10 5HiBH50 2, 3, 4 15, 20, 30, 40, 50 50 30/25 10
60HiBE60 2, 3, 4 5, 10, 15, 20, 30, 40, 50, 60 10 7.5/5 2.5HiBS60 2, 3, 4 5, 10, 15, 20, 30, 40, 50, 60 25 14/10 5
100HiBE100 2, 3, 4 5, 10, 15, 20, 30, 40, 50, 60, 75, 100 25 14/10 5HiBS100 2, 3, 4 15, 20, 30, 40, 50, 60, 75, 100 50 30/25 10HiBH100 2, 3, 4 15, 20, 30, 40, 50, 60, 75, 100 65 42/36 18
225HiBE225 21), 3, 4 125, 150, 175, 200, 225 35 25/18 7.5HiBS225 21), 3, 4 125, 150, 175, 200, 225 50 35/25 10
HiBH225 2
1)
, 3, 4 125, 150, 175, 200, 225 65 42/36 18
400
HiBE400 21), 3, 4 250, 300, 350, 400 35 30 18HiBS400 21), 3, 4 250, 300, 350, 400 50 42 22HiBH400 21), 3, 4 250, 300, 350, 400 85 65 25HiBL400 21), 3, 4 250, 300, 350, 400 125 100 30
600
HiBE600 21), 3, 4 500, 600 50 45 22HiBS600 21), 3, 4 500, 600 100 65 25HiBH600 21), 3, 4 500, 600 100 85 35HiBL600 21), 3, 4 500, 600 125 100 35
800
HiBE800 21), 3, 4 700, 800 50 45 25HiBS800 21), 3, 4 700, 800 100 65 25HiBH800 21), 3, 4 700, 800 100 85 35HiBL800 21), 3, 4 700, 800 125 100 35
Frame ModelNumber of
polesRated current (A)
Breaking capacity [Icu] (kA r.m.s.)
220/240V 380/415V 600V
50 HiBL50NE 3, 4 20-50 125 85 35100 HiBL100NE 3, 4 40-100 125 85 35225 HiBL225NE 3, 4 90-225 (250)2) 125 85 35
400HiBS400NE 3, 4 200-400 85 50 30HiBL400NE 3, 4 200-400 125 85 35HiBX400NE 3, 4 200-400 150 130 65
600HiBS600NE 3, 4 302-600 (630)3) 100 65 35HiBL600NE 3, 4 302-600 (630)3) 125 85 42HiBX600NE 3, 4 302-600 (630)3) 150 130 65
800HiBS800NE 3, 4 405-800 100 65 35HiBL800NE 3, 4 405-800 125 85 42HiBX800NE 3, 4 405-800 150 130 65
1000 HiBS1000NE 3, 4 505-1000 100 100 50HiBL1000NE 3, 4 505-1000 150 130 65
1200HiBS1200NE 3, 4 605-1200 100 100 50HiBL1200NE 3, 4 605-1200 150 130 65
Frame Model Number ofpoles
Rated current (A) Breaking capacity [Icu] (kA r.m.s.)220/240V 380/415V 600V
50HiBL50NT 3, 4 15, 20, 30, 40, 50 125 85 35HiBX50NT 3, 4 15, 20, 30, 40, 50 150 130 65
100
HiBS100J2, 3, 4
12.5-16, 16-20, 20-25, 25-3232-40, 40-50, 50-63, 63-80, 80-100
50 30/25 10HiBH100J 65 42/36 18HiBL100NT 3, 4 15, 20, 30, 40, 50, 60, 75, 100 125 85 35HiBX100NT 3, 4 15, 20, 30, 40, 50, 60, 75, 100 150 130 65
225HiBL225NT 3, 4 125, 150, 175, 200, 225 (250)2) 125 85 35HiBX225NT 3, 4 125, 150, 175, 200, 225 150 130 65
250
HiBE250J
21), 3, 4100-125, 125-160, 160-200200-250
35 25/18 7.5HiBS250J 50 35/25 10
HiBH250J 65 42/36 18
7/22/2019 04LV MV(eng)24P
10/24
Miniature Series
Miniature Circuit Breaker [ MCB ] Residual Current Circuit Breaker [ RCCB, RCBO ]
Miniature Switch Disconnector [ MSD ] Mini Breaker [HBD, HiBC]
HYUNDAI Miniature Series are the perfect solution to protect electric overload, short circuit
and earth leakage in the household and commercial installations.
With consistent and elegant appearances, the Hyundai Miniature Series provide various selection, easy
installation, economic benet and high reliability based on international standard IEC.
HiBD63-N HiRC63-N HiRO40 HBD51h
Qualied Standard & Approval
Standard IEC 60898 IEC 60947-2 IEC 61008
IEC 61009
IEC 60947-3
Approval ISO 18001, 14001, 9001 CE KEMA
BV
GOST-R
TSE
10 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
Miniature Circuit Breaker
Model HiBD125 HiBD63h HiBD63-N HiBD63-NS HiBD63-S HiBD63-E
Standard IEC/EN60947-2 IEC/EN60898 IEC/EN60898 IEC/EN60898 IEC/EN60898 IEC/EN60898
Number of poles (P)1, 2, 3, 4,1+N, 3+N
1, 2, 3, 4,1+N, 3+N
1, 2, 3, 4,1+N, 3+N
1+N(1 pole size)
1, 2, 3, 4 1, 2, 3, 4
Rated current [In] (A) 63, 80, 100, 1251, 2, 3, 4, 5, 6,
10, 13, 15, 16, 20,25, 32, 40, 50, 63
1, 2, 3, 4, 5, 6,10, 13, 15, 16, 20,25, 32, 40, 50, 63
1, 2, 3, 4, 6,10, 13, 16,
20, 25, 32, 40
1, 2, 3, 4, 5, 6,10, 13, 15, 16,20, 25, 32, 40
1, 2, 3, 4, 5, 6,10, 13, 15, 16,20, 25, 32, 40
Rated insulation voltage [Ui] (V) AC500 AC500 AC500 AC500 AC500 AC500
Rated operational voltage [Ue] (V) AC240/4151) AC240/4151) AC240/4151) AC240 AC240/4151) AC240/4151)
Rated impulse withstand voltage [Uimp] (kV) 5 4 4 3 4 4
Rated conditional short-circuit current (kA) 10 10 66(1-25A),
4.5(32-40A)4.5 3
Rated
short-circuit
breaking
capacity [Icu]
(kA r.m.s.)
IEC60898
AC220/240V 10 10 66(1-25A),
4.5(32-40A)4.5 3
AC380V 10 10 66(1-25A),
4.5(32-40A)4.5 3
AC400/460V 10 10 66(1-25A),
4.5(32-40A)4.5 3
IEC60947-2AC220/240V 15 15 10 10 7.5 6
AC400/460V 15 15 10 10 7.5 6
Ics (=% Icu) 75 75 100 100 100 100
Tripping characteristic (curve) B, C, D B, C, D B, C, D B, C B, C B, C
Durability
(times)
Electrical 10,000 10,000 10,000 10,000 10,000 10,000
Mechanical 20,000 20,000 20,000 20,000 20,000 20,000
operating frequency per hour 120 120 120 120 120 120
Accessories
Auxiliary switch
Trip alarm switch
Auxiliary & Trip alarm switch
Shunt trip
Shunt trip & Auxiliary switch
Under voltage trip
1)AC415V is not applicable for 1P and 1P+N breaker.
7/22/2019 04LV MV(eng)24P
11/24
Residual Current Circuit Breaker
11www.hyundai-elec.com
VCBVCACBMCMINIATUREMCCB
1)AC460V is not applicable for 1P breaker.
1)AC415V is not applicable for 1P breaker.
1) AC415V is not applicable for 2P(1P+N) and 1P+N breaker.
Mini Breaker
Miniature Switch Disconnector
Model HiRC100-N HiRC63-N HiRC63 HiRO40 HiRD125 HiRD63 HiRD32
Standard IEC/EN61008 IEC/EN61008 IEC/EN61008 IEC/EN61009 IEC/EN61009 IEC/EN61009 IEC/EN61009
Current characteristic (type) AC, A AC, A AC AC AC AC AC
Number of poles (P) 2(1+N), 4(3+N) 2(1+N), 4(3+N) 2(1+N), 4(3+N) 1+N 1+N, 2, 3, 3+N, 4 1+N, 2, 3, 3+N, 4 1+N, 2, 3, 3+N, 4Rated current [In] (A) 63, 80, 100
16, 25, 32,40, 63
16, 25, 32,40, 63
1, 3, 5, 6, 10,16, 20, 25, 32, 40
63, 80, 100, 125 40, 50, 631, 2, 3, 4, 5, 6, 10, 13,
15, 16, 20, 25 , 32
Rated residual current [In] (mA)30, 100, 300,
50010, 30, 100,
300, 50010, 30, 100,
300, 50010, 30, 100,
300, 50010, 30, 100,
300, 50010, 30, 100,
300, 50010, 30, 100,
300, 500
Rated insulation voltage [Ui] (V) AC500 AC500 AC500 AC500 AC500 AC500 AC500
Rated operational voltage [Ue] (V) AC240/4151) AC240/4151) AC240/4151) AC240 AC240/4151) AC240/4151) AC240/4151)
Rated impulse withstand voltage [Uimp] (kV) 5 5 5 5 5 5 5
Rated conditional short-circuit current (kA) 10 6 6 4.5 10 6 6
Ratedshort-circuitbreakingcapacity
IEC60898
[Icu] (kA r.m.s.)
AC220/240V - - - 4.5 10 6 6
AC380V - - - 4.5 10 6 6
AC400/460V - - - 4.5 10 6 6
Ics (=% Icu) - - - 75 75 75 75
Tripping characteristic (curve) - - - C B, C, D B, C, D B, C, D
Durability
(times)
Electrical 10,000 10,000 10,000 10,000 10,000 10,000 10,000Mechanical 20,000 20,000 20,000 20,000 20,000 20,000 20,000
Operating frequency per hour 120240(16,25A),
120(32,40,63A)240(16,25A),
120(32,40,63A)120 120 120 120
Model HBD51D HBD52D HBD53D HBD51HD HBD52HD HBD53HD HBD101HD HBD102HD HBD103HD HBD101HDC HBD102HDC HBD103HDC
Standard IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2
Number of poles (P) 1 2 3 1 2 3 1 2 3 1 2 3
Rated current (A) 10, 15, 20, 30, 40, 50 10, 15, 20, 30, 40, 50 10,15,20,30,40,50,60,70,80,90,100 10,15,20,30,40,50,60,70,80,90,100
Rated insulation voltage [Ui] (V) AC460 AC460 AC460 AC460
Rated operational voltage [Ue] (V) AC240/4601) AC240/4601) AC240/4601) AC240/4601)
Rated impulse withstand voltage [Uimp] (kV) 6 6 6 6
Ratedshort-circuitbreakingcapacity
Ultimate [Icu](kA r.m.s.)
AC220/240V, 50-60Hz 5 10 10 10
DC125V 5 10 10 10
Service [Ics] % of [Icu] 50 50 50 50
Terminal connection Screw Screw Screw Cage lug
Model HBD51 HBD52 HBD53 HBD51H HBD52H HBD53H HBD101H HBD102H HBD103H HBD101HC HBD102HC HBD103HC
Standard IEC60947-2 IEC60947-2 IEC60947-2 IEC60947-2
Number of poles (P) 1 2 3 1 2 3 1 2 3 1 2 3
Rated current (A) 10, 15, 20, 30, 40, 50 10, 15, 20, 30, 40, 50 10,15,20,30,40,50,60,70,80,90,100 10,15,20,30,40,50,60,70,80,90,100
Rated insulation voltage [Ui] (V) AC460 AC460 AC460 AC460
Rated operational voltage [Ue] (V) AC240/4601) AC240/4601) AC240/4601) AC240/4601)
Rated impulse withstand voltage [Uimp] (kV) 6 6 6 6
Ratedshort-circuitbreakingcapacity
Ultimate [Icu](kA r.m.s.)
AC220/240V, 50-60Hz 5 10 10 10
DC125V 5 10 10 10
Service [Ics] % of [Icu] 50 50 50 50
Terminal connection Screw Screw Screw Cage lug
Model HiSD125 Rated operational voltage [Ue] (V) AC240/4151)
Standard IEC/EN60947-3 Rated impulse withstand voltage [Uimp] (kV) 4
Number of poles (P) 1, 2, 3, 4
Durability (times)
Electrical 10,000
Rated current [In] (A) 16, 32, 63, 100, 125 Mechanical 20,000
Rated insulation voltage [Ui] (V) AC500 operating frequency per hour 120
7/22/2019 04LV MV(eng)24P
12/24
Contactor & Overload RelayHYUNDAI Contactor & Overload Relay employs a modular design, which allows quick and simple mounting of
auxiliary contact blocks, timers, mechanical latching blocks, etc.
With highly advanced design for industrial applications such as motor control centers,
the HYUNDAI contactor is appropriate for various control systems.
It is also favored by shipyards and power plants whose criteria includes high reliability and performance.
UMC225
Qualied Standard & Approval
Standard IEC 60947
EN 60947
UL 508
BS 47794, BS 5424, BS 4941
VDE 0660
DNV
KS C4504
JISC 8328, JEM 1038
Approval ISO 18001, 14001, 9001
CE (Community European / TU..
V Rheinland)
KERI
KS
UL / C-UL
TSE
GOST-R
CCC
KR, ABS, BV, NK, LR
UMC9
12 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
U-Series
Magnetic Contactor
ModelCapacity (IEC60947, AC-3 [Ie], kW/A) Durability
(at AC440V, 1000 times) Operation
current
Auxiliarycontact
(standard)
Dimensions
(WxHxD, mm)AC200 /240V AC380 / 440V AC500 / 550V AC660 /690V AC1000V Electrical Mechanical
UMC9 2.5/9 4/9 4/7 5.5/6 - 2,500 25,000AC,DC 1NO or 1NC
44x75x80(AC)44x75x112(DC)UMC12 3.5/12 5.5/12 7.5/12 7.5/9 - 2,500 25,000
UMC18 4.5/18 7.5/18 8.5/15 7.5/9 - 2,500 15,000
AC,DC -45x83x94(AC)
45x83x127(DC)UMC25 5.5/25 11/25 15/22 15/18 - 2,500 15,000
UMC32 7.5/32 15/32 18.5/28 18.5/22 - 2,000 15,000
UMC40 11/40 18.5/40 22/32 22/23 - 2,000 15,000
AC,DC 2NO+1NC(DC only)
55x106x111UMC50 15/50 22/50 30/43 30/28 - 2,000 15,000
UMC65 18.5/65 30/65 33/60 33/35 - 2,000 15,000
UMC75 22/75 37/75 37/64 37/42 - 2,000 10,000
AC,DC2NO+1NC(DC only)
70x140x128UMC85 25/85 45/85 50/75 45/45 - 2,000 10,000
UMC100 30/100 55/100 50/85 45/65 - 2,000 10,000
UMC115 37/115 60/115 59/100 55/65 65/50 1,000 5,000
AC/DC 2NO+2NC 103x155x146UMC130 40/130 65/130 70/120 75/82 75/54 1,000 5,000
UMC150 45/150 75/150 90/140 90/120 90/66 1,000 5,000
UMC185 55/185 90/185 110/180 110/120 110/78 1,000 5,000
AC/DC 2NO+2NC 138x204x174UMC225 75/225 132/225 132/200 132/150 132/96 1,000 5,000
UMC265 80/265 147/265 150/225 160/173 160/113 1,000 5,000
UMC300 90/300 160/300 200/273 200/220 200/141 1,000 5,000
AC/DC 2NO+2NC 163x243x203UMC400 125/400 220/400 250/300 250/300 250/178 1,000 5,000UMC500 140/500 250/500 300/426 335/360 275/192 50 500
UMC630 190/630 330/500 330/500 400/412 300/213 50 500AC/DC 2NO+2NC 276x314x253
UMC800 220/800 440/800 500/720 500/630 400/284 50 500
7/22/2019 04LV MV(eng)24P
13/24
13www.hyundai-elec.com
VCBVCACBMCMINIATUREMCCB
Thermal Overload Relay
Model UTH12 UTH32 UTH65 UTH100 UTH150 UTH265 UTH400 UTH800
Rated
current
(A)
0.12-0.15-0.18
0.18-0.22-0.26
0.25-0.3-0.35
0.34-0.42-0.5
0.5-0.6-0.7
0.6-0.75-0.9
0.8-1-1.21.1-1.35-1.6
1.5-1.8-2.1
2-2.5-3
2.8-3.5-4.2
3-4-5
4-5-6
5.6-6.8-8
6-7.5-9
8-10-12
0.12-0.15-0.18
0.18-0.22-0.26
0.25-0.3-0.35
0.34-0.42-0.5
0.5-0.6-0.7
0.6-0.75-0.9
0.8-1-1.2
1.1-1.35-1.6
1.5-1.8-2.12-2.5-3
2.8-3.5-4.2
3-4-5
4-5-6
5.6-6.8-8
6-7.5-9
8-10-12
12-15-18
15-18.5-22
17-21-25
22-27-32
7-8.5-10
8-10-12
12-15-18
15-18.5-22
17-21-25
22-27-32
28-34-40
34-42-50
45-55-65
17-21-25
22-27-32
28-34-4034-42-50
45-55-65
52-63-75
59-72-85
70-85-100
48-64-8069-92-115
78-104-130
90-120-150
48-64-80
69-92-115
78-104-130
90-120-150
111-148-185
135-180-225
159-212-265
90-120-150
111-148-185135-180-225
159-212-265
180-240-300
240-320-400
300-400-500
378-504-630
480-640-800
Auxiliary contact(standard) 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC
Dimensions(WxHxD, mm) 45x79x76 45x81x91 55x94x105 70x108x123 180x159x187 180x185x185 180x205x185 245x223x197
Applied
contactor
UMC9
UMC12
UMC18UMC25UMC32
UMC40UMC50UMC65
UMC75UMC85
UMC100
UMC115UMC130UMC150
UMC185UMC225UMC265
UMC300
UMC400
UMC500UMC630UMC800
Separate mountingblock (option) UTHMB12 UTHMB32 UTHMB65 UTHMB100 - - - -
7/22/2019 04LV MV(eng)24P
14/24
14 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
Control Relay
Auxiliary Contact Block
Mechanical Interlock Unit
Surge Absorber
Contactor & Overload Relay
Model Auxiliary contact Operation current
UMX04 0NO+4NC
AC
UMX13 1NO+3NC
UMX22 2NO+2NC
UMX31 3NO+1NC
UMX40 4NO+0NC
Electronic Timer Block
Model Control voltage Applicable product
UET1 AC/DC90-240V UMC9-100,
UMX, UMTUET2 AC/DC24-60V
Mechanical Latching Block
Model Control voltage Applicable product
ULB100
AC/DC24
UMC9-100,
UMX, UMT
AC/DC48
AC/DC100-125
AC/DC200-240
AC440
Item Model Control voltage Applicable product
RC-unit
URC32
AC24-48VUMC9-32,
UMXAC110-220V
AC240-380V
URC100
AC24-48V
UMC40-100AC110-220V
AC240-380V
Clamping diode UCD100 DC24-125V UMT
Model Applied contactors
UTL65 S UMC9-65
UTL100 UMC75-100
UTL265 UMC115-265
UTL400 UMC300-800
Model Auxiliary contact Applicable product Mounting position
UAB02 0NO+2NC
UMC9-100UMX, UMT
Front
UAB11 1NO+1NC
UAB20 2NO+0NC
UAB04 0NO+4NC
UAB13 1NO+3NC
UAB22 2NO+2NC
UAB31 3NO+1NC
UAB40 4NO+0NC
UAL65 1NO+1NC UMC9-65
SideUAL100 1NO+1NC UMC75-100
UAL400 1NO+1NC UMC115-800
Model Auxiliary contact Operation current
UMT04 0NO+4NC
DC
UMT13 1NO+3NC
UMT22 2NO+2NC
UMT31 3NO+1NC
UMT40 4NO+0NC
7/22/2019 04LV MV(eng)24P
15/24
Accessories
15www.hyundai-elec.com
Feature Item Model
Main contact UMCTIP
Terminal
protection
cover
UMC_PC
Spare Part
Feature Item Model
Coil UMCOL
Arc chute UMCHT
Front Safety Cover
Model Applicable product
UMC100IC UMC9-100, UMX, UMT
UMC150IC UMC115-150
UMC265IC UMC185-265
UMC400IC UMC300-500
UMC800IC UMC630-800
VCBVCACBMCMINIATUREMCCB
1.Contactor UMC2.Front safety cover
3.Auxiliary contact block (Front mounting) UAB
4.Auxiliary contact block (Side mounting) UAL
5.Mechanical latching block ULB
6.Electronic timer block UET
7.Mechanical interlock unit UTL
8.Surge absorber URC/UCD
9.Thermal overload relay UTH
The applicable accessories of each contactor are not same as above. For exact application to each contactor, please refer to product catalogue.
1 7
1
9
4
4
56
33
2
8
Moving contacts
Fixed contacts
Mainterminal cover
Coilterminal cover
Auxiliary contactterminal cover
7/22/2019 04LV MV(eng)24P
16/24
16 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
HiMC130HiMC22 + HiTH22
Capacitor Switching ContactorHiMK
Hi-Series
Magnetic Contactor
Contactor & Overload Relay
ModelCapacity (AC3, kW/A)
Auxiliary contact Operation current200-240V 380-440V 500-550V 660-690V 1,000V
HiMC9 2.2/10 4/9 4/7 5.5/7 - 1NO+1NC AC, DC
HiMC12 3.7/13 5.5/12 7.5/12 7.5/9 - 1NO+1NC AC, DC
HiMC18 4.5/18 7.5/18 8.5/15 7.5/9 - 1NO+1NC AC, DC
HiMC22 5.5/22 11/22 15/22 15/18 - 1NO+1NC AC, DC
HiMC32 7.5/32 15/32 18.5/28 18.5/22 - 2NO+2NC AC, DCHiMC40 11/40 18.5/40 22/32 22/26 - 2NO+2NC AC, DC
HiMC50 15/50 22/50 30/45 25/31 - 2NO+2NC1) AC, DC
HiMC65 18.5/70 30/65 37/60 37/44 - 2NO+2NC1) AC, DC, AC/DC
HiMC80 22/80 37/80 45/64 45/52 - 2NO+2NC1) AC, DC, AC/DC
HiMC90 25/90 45/90 50/80 50/60 - 2NO+2NC1) AC, DC, AC/DC
HiMC110, HiMC110B 2) 30/110 55/110 60/110 55/65 65/50 2NO+2NC1) AC, DC, AC/DC
HiMC130 37/130 65/130 70/120 60/70 75/54 2NO+2NC1) AC, DC, AC/DC
HiMC150, HiMC150B 2) 45/150 75/150 90/140 90/100 90/66 2NO+2NC1) AC, DC, AC/DC
HiMC180 55/180 90/180 110/180 110/120 110/78 2NO+2NC1) AC, DC, AC/DC
HiMC220 63/220 110/220 132/200 132/150 132/96 2NO+2NC1) AC, DC, AC/DC
HiMC260, HiMC260B 2) 75/260 132/260 150/220 160/173 160/113 2NO+2NC1) AC, DC, AC/DC
HiMC300 90/300 160/300 160/273 200/220 200/141 2NO+2NC1) AC, DC, AC/DC
HiMC400 125/400 220/400 220/350 250/300 250/178 2NO+2NC1) AC, DC, AC/DC
HiMC500 140/500 250/500 300/426 335/360 275/192 2NO+2NC1) AC, DC, AC/DC
HiMC630 190/630 330/630 330/500 400/412 300/213 2NO+2NC1) AC, DC, AC/DC
HiMC800 220/800 440/800 500/720 500/630 400/284 2NO+2NC1) AC, DC, AC/DC
Model
(AC operation)
Rating of 3-phase capacitor 50-60Hz(at ambient temperature 55C) Composed devices Dimension
Max. power Contactor Capacitor switching unit External size
AC-6b
(AC operation) Model
AuxiliaryWxHxD(mm)
200V
kVAR
230V240VkVAR
400V415VkVAR
440V
kVAR
500V550VkVAR
690V
kVAR
NO(53-54)
NC(51-52)
HiMK9 215 5 9.7 9.7 14 14 HiMC9
HiAD50 10 1
44x166x123
HiMK9 12 HiAD50 01 1
HiMK12 216.7 6.7 12.5 12.5 18 18 HiMC12
HiAD50 10 1
HiMK12 12 HiAD50 01 1
HiMK18 218.5 8.5 16.7 16.7 24 24 HiMC18
HiAD50 10 1
HiMK18 12 HiAD50 01 1
HiMK22 2110 10 18 18 26 26 HiMC22
HiAD50 10 1
HiMK22 12 HiAD50 01 1
HiMK32 32 14 16 27.5 30 34 45 HiMC32 HiAD50 10 1
63x166x123HiMK32 23 HiAD50 01 1
HiMK40 3220 20 30 33.3 48 48 HiMC40
HiAD50 10 1
HiMK40 23 HiAD50 01 1
HiMK50 3221 24 40 45 50 65 HiMC50
HiAD50 10 170x178x136
HiMK50 23 HiAD50 01 1
1)The auxiliary contact for DC is 2NO+1NC. 2)HiMC110B, HiMC150B, HiMC260B: Compact type
7/22/2019 04LV MV(eng)24P
17/24
Deluxe typeStandard type
HiTH22 HiTH90 HiTH130
17www.hyundai-elec.com
Thermal Overload Relay
Digital Motor Protection Relay
Standard Type
Deluxe Type
Model
Function Wiring of main circuit
Allowable current partitionOvercurrent
Phasefailure
Phaseunbalance
RestrictionReversephase
Pin Screw Tunnel
HiMP22K I
HiMP40K I
HiMP50K I
Inverse
HiMP22: 0.3-1.5A, 1-5A, 4.4-22AHiMP40: 8-40AHiMP50: 10-50A
HiMP150K I
HiMP300K IInverse
HiMP150: 30-150A
HiMP300: 60-300A
HiMP22K N
HiMP40K N
HiMP50K N
Inverse/
Reverse
HiMP22: 0.3-1.5A, 1-5A, 4.4-22AHiMP40: 8-40AHiMP50: 10-50A
HiMP150K N
HiMP300K NInverse/Reverse
HiMP150: 30-150A
HiMP300: 60-300A
Model
Function Wiring of main circuit
Allowable currentpartitionOver
currentUndercurren
Phasefailure
Phaseunbalance
RestrictionReversephase
Shortcircuit
Leakagecurrent
Screw Tunnel
HiMP60K S
0.5-6A, 5-60AHiMP60K I
HiMP60K Z
Model HiTH22 HiTH40 HiTH50 HiTH90 HiTH130 HiTH220 HiTH300 HiTH500 HiTH800
Rated
current
(A)
0.12-0.180.18-0.260.25-0.350.34-0.50.5-0.70.6-0.9
0.8-1.21.1-1.61.5-2.1
2-32.8-4.2
3-54-6
7-109-13
12-1816-22
7-10
9-1312-1816-2218-2624-3228-40
18-2624-3228-4036-50
28-4036-5045-6560-8070-90
48-8078-130
78-130108-180132-220
132-220180-300
180-300240-400300-500
378-630480-800
Applied
contactor
HiMC9HiMC12HiMC18HiMC22
HiMC32HiMC40
HiMC50
HiMC65HiMC80HiMC90
HiMC110B
HiMC110HiMC130
HiMC150B
HiMC150HiMC180HiMC220
HiMC260B
HiMC260HiMC300
HiMC400HiMC500
HiMC630HiMC800
Separate mountingblock (option) ITHMB22 ITHMB40 ITHMB50 ITHMB90 - - - - -
VCBVCACBMCMINIATUREMCCB
7/22/2019 04LV MV(eng)24P
18/24
Designed for both industrial and marine application, HYUNDAI Air Circuit Breakers have
innovated structure, various protection, and reliable performance.
Air Circuit Breaker
UAN Type
Qualied Standard & Approval
Standard
IEC 60947-2
EN 60947-2
AS 3972-2
NEMA PUB NO. SG3
ANSI C37.13
VDE 0660
GOST-R 50030.2-99 9
GOST-R 50030.1-2000
Approval
ISO 18001, 14001, 9001
CE (Community European / TU..
V Rheinland)
KERI
KS
GOST-R
CCC
KR, GL, LR, ABS, BV, NK
18 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
UAN Type
Model UAN06 UAN08 UAN10 UAN12 UAN16 UAN20 UAN32 UAN40 UAN50
Rated current (A) 630 800 1,000 1,250 1,600 2,000 3,200 4,000 5,000
Number of pole 3, 4
Utilization category B
Rated insulation voltage (Ui) (V) AC1,000
Rated operation voltage (Ue) (V) AC690
Rated breaking
capacity (kA sym) [Icu]
with Inst.
Icu=100% Ics
AC690V 65 65 65 65 65 65 85 85 85
AC500V 85 85 85 85 85 85 100 100 100
AC415V below 85 85 85 85 85 85 100 100 100
Rated making
capacity (kA peak) [Icm]
with Inst.
Icu=100% Ics
AC690V 143 143 143 143 143 143 187 187 187
AC500V 187 187 187 187 187 187 220 220 220
AC415V below 187 187 187 187 187 187 220 220 220
Rated impulse withstand voltage (Uimp) (kV) 12
Rated short-time withstandcurrent [Icw] (kA r.m.s.)
1 sec 65 65 65 65 65 65 85 85 85
Rated latching current (kA) 65 65 65 65 65 65 85 85 85
Total breaking time (sec) 0.05
Closingoperatingtime
Charging time (sec) max. 10
Closing time (sec) max. 0.04
Dimensions (mm)
(3pole, Draw-out type)
Height 460 460
Width 328 399 656
Depth 405 439.2
7/22/2019 04LV MV(eng)24P
19/24
HiAN and HiAH Type
HiAS Type
19www.hyundai-elec.com
VCBVCACBMCMINIATUREMCCB
Model HiAN06 HiAN08 HiAN10 HiAN12 HiAN16 HiAN20 HiAN25 HiAN32 HiAN40 HiAN50 HiAN63
Rated current (A) 630 800 1,000 1,250 1,600 2,000 2,500 3,200 4,000 5,000 6,300
Number of pole 3, 4
Utilization category B
Rated insulation voltage (Ui) (V) AC1,000
Rated operation voltage (Ue) (V) AC690
Rated breakingcapacity (kA sym) [Icu]with Inst.Icu=100% Ics
AC690V 50 50 50 50 50 65 65 65 85 100 100
AC500V 70 70 70 70 70 70 85 85 100 120 120
AC415V below 70 70 70 70 70 85 85 85 100 120 120
Rated makingcapacity (kA peak) [Icm]with Inst.
Icu=100% Ics
AC690V 105 105 105 105 105 143 143 143 187 220 220
AC500V 154 154 154 154 154 154 187 187 220 291 291
AC415V below 154 154 154 154 154 187 187 187 220 291 291Rated impulse withstand voltage (Uimp) (kV) 8
Rated short-time withstandcurrent [Icw] (kA r.m.s.)
1 sec 65 65 65 65 65 70 85 85 75 100 100
Rated latching current (kA) 65 65 65 65 65 70 85 85 75 100 100
Total breaking time (sec) 0.04Closingoperatingtime
Charging time (sec) max. 10
Closing time (sec) max. 0.04 0.06
Weight
(kg)
3pole, Fixed type 43 43 43 49 49 60 63 65
3pole, Draw-out type 65 65 65 72 72 87 92 96 115 210 230
4pole, Fixed type 51 51 51 58 58 69 76 83
4pole, Draw-out type 76 76 76 85 85 100 110 120 135 230 250
Dimensions (mm)
(3pole, Draw-out type)
Height 490 478
Width 320 410 480 984Depth 461.2 481
Model HiAS06 HiAS08 HiAS10 HiAS12 HiAS16 HiAS20 HiAS25 HiAS32
Rated current (A) 630 800 1,000 1,250 1,600 2,000 2,500 3,200
Number of pole 3, 4
Utilization category B
Rated insulation voltage (Ui) (V) AC1,000
Rated operation voltage (Ue) (V) AC690
Rated breakingcapacity (kA sym) [Icu]with Inst.
Icu=100% Ics
AC690V 42 42 42 42 42 50 50 50
AC500V 50 50 50 50 50 65 65 65
AC415V below 50 50 50 50 50 65 65 65Rated makingcapacity (kA peak) [Icm]with Inst.Icu=100% Ics
AC690V 88.2 88.2 88.2 88.2 88.2 105 105 105
AC500V 110 110 110 110 110 143 143 143
AC415V below 110 110 110 110 110 143 143 143
Rated impulse withstand voltage (Uimp) (kV) 8
Rated short-time withstandcurrent [Icw] (kA r.m.s.)
1 sec 42 42 42 42 42 50 50 50
Rated latching current (kA) 42 42 42 42 42 50 50 50
Total breaking time (sec) 0.04Closingoperatingtime
Charging time (sec) max. 10
Closing time (sec) max. 0.04
Weight
(kg)
3pole, Fixed type 43 43 43 49 49 60 63 65
3pole, Draw-out type 65 65 65 72 72 87 92 96
4pole, Fixed type 51 51 51 58 58 69 76 83
4pole, Draw-out type 76 76 76 85 85 100 110 120
Dimensions (mm)
(3pole, Draw-out type)
Height 459
Width 320 410
Depth 461.2
7/22/2019 04LV MV(eng)24P
20/24
20 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
Vacuum ContactorHYUNDAI Vacuum Contactors are designed and manufactured for frequent
switchings, especially taking into account safety and quality assurance.
They are suitable for switching and controlling squirrel cage and
slipring motors, medium voltage loads and resistance furnaces,
and capacitors and transformers.
Qualied Standard & Approval
Standard IEC 60470 UL 347
NEMA ICS 3
Approval ISO 18001, 14001, 9001 KERI
UL, c-UL
KR, GL, LR, NK
UVC Type
Fixed type
X1 Without fuse holder
A1 With single fuse holder
Draw-out type
B1 B2 Without fuse holder
D1 D2 With single fuse holder
Operating
method
Continuously energized 32C 34C 62C 64C 32C 34C 62C 64CLatched 32L 34L 62L 64L 32L 34L 62L 64L
Rated insulation voltage (kV) 3.6 7.2 3.6 7.2
Rated operation voltage (kV) 3.3 6.6 3.3 6.6
Rated frequency (Hz) 50/60
Rated current (A) 200 400 200 400 200 400 200 400
Withstand
voltage
Impulse (kV) 60
Power frequency (1min, kV) 20
Control dielectric strength(min, kV) 2
Utilization category AC3
Breaking capacity 4kA (O-3min-CO-3min-CO, 50MVA at 7.2kV)
Short-timecurrent[kA]
1 sec 6.3
30 sec 3
Mechanical
lifetime
Continuously energized(1,000 times) 1,000
Latched(1,000 times) 250
Electrical lifetime (1,000 times) 300
Control voltage (V) AC/DC100-125, AC/DC200-230
Auxiliary contact 3a2b
Applicable
load capacity
Motor (kW) 750 1,500 1,500 3,000 750 1,500 1,500 3,000
Transformer (kVA) 1,000 2,000 2,000 4,000 1,000 2,000 2,000 4,000
Condensor (kVAR) 750 1,200 1,500 2,000 750 1,200 1,500 2,000
Weight without fuse(kg)
X1 19
A1 28
B1 B2 33
D1 D2 35
B1 B2 35
D1 D2 38
Structure
Ratings
7/22/2019 04LV MV(eng)24P
21/24
1) Double fuse holder is not applicable to 12kV.
2) In case of 3.6/7.2kV xed type without fuse holder, 3a3b is standard.
3) The weight of 3.6/7.2kV draw-out type is based on F1 cradle.
4) The weight of 12kV draw-out type is measured without cradle.
21www.hyundai-elec.com
VCBVCACBMCMINIATUREMCCB
HCA Type
Fixed type
F Without fuse holder
A With single fuse holder
J With double fuse holder1)
Draw-out type
B Without fuse holder
D With single fuse holder
H With double fuse holder1)
Operating
method
Continuously energized 32C 34C 62C 64C 82C 84C 32C 34C 62C 64C 82C 84CLatched 32L 34L 62L 64L 82L 84L 32L 34L 62L 64L 82L 84L
Rated insulation voltage (kV) 3.6 7.2 12 3.6 7.2 12
Rated operation voltage (kV) 3.3 6.6 11 3.3 6.6 11
Rated frequency (Hz) 50/60
Rated current (A) 200 400 200 400 200 400 200 400 200 400 200 400
Withstand
voltage
Impulse (kV) 45 60 75 45 60 75
Power frequency (1min, kV) 16 20 28 16 20 28
Control dielectric strength(min, kV) 2 2 2 2 2 2
Utilization category AC3 AC4 AC3 AC4
Breaking capacity 4kA (O-3min-CO-3min-CO)
Short-timecurrent[kA]
1 sec 6.3 6.3 6.3 6.3 6.3 6.3
30 sec 2.4 2.4 2.4 2.4 2.4 2.4
Mechanicallifetime
Continuously energized
(1,000 times)1,000 1,000 1,000 1,000 1,000 1,000
Latched(1,000 times) 250 250 250 250 250 250
Electrical lifetime (1,000 times) 300
Control voltage (V) AC110/125/220, DC110/125/220
Auxiliary contact 2a2b2) 2a2b 2a2b2) 5a5b
Applicable
load capacity
Motor (kW) 750 1,500 1,500 3,000 3,000 6,000 750 1,500 1,500 3,000 3,000 6,000
Transformer (kVA) 1,000 2,000 2,000 4,000 4,000 8,000 1,000 2,000 2,000 4,000 4,000 8,000
Condensor (kVAR) 750 1,200 1,500 2,000 3,000 4,000 750 1,200 1,500 2,000 3,000 4,000
Weight without fuse(kg)
F 21
A 30
J 33
F 22
A 32
J 35
F 61
A 68
B 383)
D 403)
H 433)
B 413)
D 433)
H 463)
B 804)
D 834)
Structure
Ratings
7/22/2019 04LV MV(eng)24P
22/24
Vacuum Circuit BreakerHYUNDAI Vacuum Circuit Breaker achieves the superior reputation with its extended life expectancy,
easy maintenance, and excellent performance for industrial facilities, power plants, and marine vessels.
IEC 62271-100
1)Model number in the square "" shall be listed as below for the rated current according to applied standard. - IEC standard: 1630A 21,250A 42,000A 62,500A 73,150A 84,000A 9400A
2) HVF224, 225, 226, 611, 614, 625, 725are applicable to GOST-R standard.
HVG typeHVF type
Qualied Standard & Approval
Standard
IEC 62271-100, 60056
ESB 150
ANSI C37.09
KSC 4611
GOST-R 52565-06
Approval
ISO 18001, 14001, 9001
KEMA
KERI
KR, GL
22 HYUNDAI HEAVY INDUSTRIES
LV & MV Circuit Breaker, Contactor & Overload Relay
TypeRated
voltage (kV)
Withstand voltage(kV)
Power-frequency/Impulse
Ratedbreaking
current(kA)Model1)
Rated current (A)1)
400 630 1,250 2,000 2,500 3,150 4,000
HVF
7.2 20/60
25 HVF114
31.5 HVF115
40 HVF116
50 HVF117
12
28/75
25 HVF214
31.5 HVF215
40 HVF216
50 HVF217
42/75
25 HVF2242)
31.5 HVF2252)
40 HVF2262)
17.5 38 / 95
25 HVF314
31.5 HVF315
40 HVF316
24/25.850/125
(65/125) 2)12.5 HVF6112)
25 HVF6142)
24 65/125 25 HVF6252)
36 70/17025 HVF714
31.5 HVF705
36/40.5 95/190 31.5 HVF7252)
HVG 7.2 20/60
8 HVG109
12.5 HVG101
20 HVG113
25 HVG114
7/22/2019 04LV MV(eng)24P
23/24
ANSI C37.09
15kV 38kV
23www.hyundai-elec.com
VCBVCACBMCMINIATUREMCCB
TypeRated
voltage (kV)
Withstand voltage(kV)
Power-frequency/Impulse
Ratedbreaking
current(kA)Model1)
Rated current (A)1)
1,200 2,000 2,500 3,000 4,000
HVF
4.76 19/60
25HVF154
HVF144
40 HVF146
50 HVF147
15 36/95
25HVF354
HVF344
40HVF346
HVF336
38 80/15031.5 HVF705
40 HVF706
1)Model number in the square "" shall be listed as below for the rated current according to applied standard. - ANSI standard: 21,200A 42,000A 62,500A 73,000A 84,000A
7/22/2019 04LV MV(eng)24P
24/24
HHIS-WC-LE-A39-14,2012.1Designed
byJCCommunication
www.hyundai-elec.com
Head Office 1000, Bangeojinsunhwan-doro Dong-gu, Ulsan, Korea Tel: 82-52-202-8101~8 Fax: 82-52-202-8100
Seoul 75, Yulgok-ro, Jongno-gu, Seoul, Korea(Sales & Marketing) Tel: 82-2-746-8519, 7510 Fax: 82-2-746-7441
Atlanta 6100 Atlantic Blvd. Suite 201, Norcross, GA30097, U.S.A. Tel: 1-678-823-7842 Fax: 1-678-823-7553
New Jersey 300 Sylvan Avenue, Englewood Cliffs, NJ, 07632, U.S.A. Tel: 1-201-816-0286, 8028 Fax: 1-201-816-4083
London 2nd Floor, The Triangle, 5-17 Hammersmith Grove, London, W6 0LG, UK Tel: 44-20-8741-0501 Fax: 44-20-8741-5620
Tokyo 8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-Cho, Chiyoda-Ku, Tokyo, 100-0006, Japan Tel: 81-3-3212-2076, 3215-7159 Fax: 81-3-3211-2093
Osaka I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, 542-0081, Japan Tel: 81-6-6261-5766, 5767 Fax: 81-6-6261-5818
Riyadh 2nd Floor, The Plaza, P.O Box 21840, Riyadh 11485, Saudi Arabia Tel: 966-1-462-2331 Fax: 966-1-464-4696
Dubai 205, Building 4, Emaar Square, Sheikh Zayed Road, Pobox 252458, Dubai, UAE Tel: 971-4-425-7995 Fax: 971-4-425-7996
Kuwait Floor 15, Al Sour Tower, Al Sour Street, Al-Qiblah, Kuwait Tel: 965-2291-5354 Fax: 965-2291-5355
Moscow World Trade Center, Ent. 3, #1902, Krasnopresnenskaya Nab. 12, Moscow, 123610, Russia Tel: 7-495-258-1381 Fax: 7-495-258-1382
Madrid Paseo De La Castellana 216, planta 0, 28046 Madrid, Spain Tel: 34-91-732-0454, 733-6069 Fax: 34-91-733-2389
Sofia 1271, Sofia 41, Rojen Blvd., Bulgaria Tel: 359-2-803-3200, 3220 Fax: 359-2-803-3203
Montgomery 201 Folmar Parkway, Montgomery, AL 36105, U.S.A. Tel: 1-334-230-9921 Fax: 1-334-240-6869
Yang hong N 9 Xi d i R d Xi b S i tifi d T h l gi Z Y g h g Ji g PR C Zi 212212 Chi