Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13 Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping Chapter 3 and 7 (Toa) 14 HVAC System Design; Entering Web Bulb; Coil Lines; Zoning; Duct; Variable Air Volume, Constant Air, Registers Chapter 6 (Toa)

Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Embed Size (px)

Citation preview

Page 1: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Zoning

HVAC 13a

CNST 305 Environmental Systems 1Dr. Berryman

13 Equipment Selection;  Variable Air Volume ; Temperature Controls; Water and Steam

Piping

Chapter 3 and 7 (Toa)

14 HVAC System Design; Entering Web Bulb; Coil Lines; Zoning; Duct; Variable Air

Volume, Constant Air, Registers 

 Chapter 6 (Toa)

Page 2: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Air Volume vs Temperature Constant Volume (CV)

Variable Air Volume (VAV)

Page 3: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

VAVTerminal

Page 4: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Zoning Components

Page 5: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Systems for Zone Control Constant Temperature, Variable

Volume (on,off) Single Zone CV Single Zone Reheat CV CV Terminal Reheat CV Dual Duct and Multizone Multiple Zone VAV ETC.

Page 6: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Single Zone CV

Air Control on/off

Air conditions controlled at thermostat for entire zone

Page 7: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Single Zone CV

Chiller

Boiler

Absorber Chiller

Pumps

Water Tower

Exhaust Fan

Air Handler

Air Handler

Perimeter Heating

Diffusers

System Controls

T

Page 8: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Single Zone CV Reheat

Page 9: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

CV Terminal Reheat

Page 10: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

CV Dual Duct

Page 11: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

CV Multizone

Page 12: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Single Zone VAV

Page 13: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

VAV Reheat

Page 14: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

VAV ReheatRoof Top Air Conditioners w/ Boilers

T

T

T

Page 15: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

VAV w/ Reheat

Page 16: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Multiple Zone VAV

Page 17: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Multiple Zone VAV

Roof Top Single Packaged Unit

T

T

T

Bypass Damper

Page 18: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Multiple Zone VAV

Water Tower

Fan Powered VAV Terminals

Diffusers

Boiler

Self-Contained Air Conditioner

T

T

T

Page 19: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Multiple Zone VAV

System Controls

T

T

T

ChillerBoiler

Absorber Chiller Pumps

Water Tower

Exhaust Fan

Air Handlers

Diffusers

VAV Terminals

Building Management System

Page 20: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

VAV Dual Duct

Page 21: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

VAV Dual Duct

System Controls

T

T

Hot Water AH

Chill Water AH

VAV Terminals

Diffusers

Direct Fired Absorber Chiller

Building Management System

Page 22: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

VAV Multizone

Page 23: Zoning HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman 13Equipment Selection; Variable Air Volume ; Temperature Controls; Water and Steam Piping

Next Time

Duct Systems