Excel Excel Life Safety Life Safety Honeywell Honeywell XLS 80e XLS 80e 2 to 8 Loop Intelligent Control 2 to 8 Loop Intelligent Control Panel Panel

XLS80e fire detection System

  • Upload
    nik

  • View
    55

  • Download
    8

Embed Size (px)

DESCRIPTION

XLS80e fire detection System Presentation

Citation preview

ID3000 2 to 8 Loop Intelligent Control PanelMarketing Plans 2000
Excel Life Safety
Marketing Plans 2000
Excel Life Safety
Error checking and correction
Up to 158,400 devices
Up to 25,500 zones
Up to 700A PSU
Marketing Plans 2000
Excel Life Safety
BREAK GLASS
PRESS HERE
elimination of nuisance alarms
design and application
Lower installed cost
Marketing Plans 2000
Excel Life Safety
Global Market Offering
Compliant with EN54
Large graphic LCD
Application software flexibility
Marketing Plans 2000
Excel Life Safety
XLS80e Applications (1)
An advanced life safety system designed for large single site and multi-site applications
Office towers
Added Value Options
Advanced detection products
Enhanced loop interface board (E-LIB)
Active and passive repeaters
DTP - Dual Transmission Path Booster I/F Kit
PSU - Power Supply Unit
LCD - Liquid Crystal Display
Marketing Plans 2000
Excel Life Safety
& Batteries & Extension Chassis
Marketing Plans 2000
Excel Life Safety
One RS-232 Card
One RS-485 Card
One ID-Net Card (*)
Sounder - rated @ 1A/30V each
Two can be programmed for German UE interface
Fault and Fire Relays
both rated @ 1A
Marketing Plans 2000
Excel Life Safety
BEK - Inputs & Outputs
Two addressable loops - 500mA
Serial Ports:
RS485 Port (optional module)
Printer Support
LIB
all detection is lost
E-LIB
Powerful microprocessor
Degrade mode
In case of main CPU failure the E-LIB will still activate sounder circuits 1-4 and the Fire Relay when an alarm is received from the loop
CPU available for other tasks
Full device count on the panel
Marketing Plans 2000
Excel Life Safety
Remote Battery/Charger
Enclosure Kit
7A PSU
mounts into
Marketing Plans 2000
4.5 AMP PSU CHARGES UP TO 38Ah (YUASA in deep back box) or 42Ah (OTHERS)
7 AMP PSU CHARGES UP TO 78Ah. Can charge over this but not in 24 hours
152.unknown
154.unknown
Temperature compensated battery charger
DTP required by EN54-4 for external PSU application
Maintains constant loop voltage over a wide range of mains and battery voltages
Fault monitoring on the power supply, mains and the batteries
Inhibits charger in case of an alarm
Marketing Plans 2000
Excel Life Safety
Power Supply Options
(for use in the Remote Enclosure)
Marketing Plans 2000
Double Extended Backbox Kit
Backbox Extension Kit
Flush Mounting Bezels
Marketing Plans 2000
Excel Life Safety
78Ah
38Ah
Standard
depth
Black/Grey (standard) -
6U x 19” Rack Mounting Assembly for 7A PSU
6U x 19” Rack Mounting Assembly
for 64 Zone LED Extension Chassis & Printer Kit
6U x 19” Rack Mounting Assembly for 256 Zone
LED Extension Chassis Kit
3U x 19” Rack Blank Cover with Mains Termination Kit
6U x 19” Rack Blank Cover with Mains Termination Kit
3U x 19” Rack Mounting Assembly for Mimic Driver Kit
6U x 19” Rack Blank Cover
3U x 19” Rack Blank Cover
All available in the standard black/grey colour
Marketing Plans 2000
Excel Life Safety
Take Your Pick!
Marketing Plans 2000
Excel Life Safety
Graphic LCD
User in control/has choice
of what is displayed
common controls
6 lines x40 characters
Short-cuts for test & disablement
Selection by direct addressing
Event type, index and actions
Panel, Zone and Device descriptors
Marketing Plans 2000
Excel Life Safety
Marketing Plans 2000
Excel Life Safety
Highest Priority
Lowest Priority
If there is insufficient room to display all 8 tabs, then the lowest (on the right) are omitted.
FIRE PRE-A FAULT DISAB TEST EVAC AUX USER
Marketing Plans 2000
Excel Life Safety
Panel and Zone Text up to 32 Characters via Keyboard
to Navigate and to Select
Marketing Plans 2000
Excel Life Safety
Fire Alarm Display
Example - 3 Zones in Alarm: 2 Devices Alarmed in Zone 2
1 Device Alarmed in Zone 1
1 other zone in Alarm - Press “Zones in Alarm” to view others
Use Navigation keys 46 to scroll through zones and display other devices, date/time of event and device % value, etc.
Short-cut key selects either device or zone disablement.
Marketing Plans 2000
Excel Life Safety
FROM P21 OF OPERATING MANUAL
3 Zones are in Pre-Alarm with 4 events in the system
2 Pre-Alarms are currently in Zone 8.
Use to scroll through zones &for device selection.
Marketing Plans 2000
Excel Life Safety
Fault Display
3 Zones are in FAULT with 4 events in the system.
Use to scroll through zones and to display device, type, value, etc.
Marketing Plans 2000
Excel Life Safety
Disablement Display
142 Devices Disabled in 3 input zones. 12 devices are disabled in Zone 2 (all input devices).
No outputs are disabled. Use to scroll through zone list and to see device details.
Excel
Disable Fire Relay and Fire Output
(if Configured)
Accept Fire Alarm
Marketing Plans 2000
Excel Life Safety
System Status Indicators
Fire condition exists
Fault condition exists
Pre-Alarm condition exists
Fire relay disabled, or fire O/P disabled/in fault
Fire relay or fire O/P is active
Marketing Plans 2000
Excel Life Safety
Programmed delays enabled
Spare for future features
Spare for future features
FIRE and FAULT/DISABLED/TEST Indication
64 Zone LED Display Module (Single Extension Chassis) Two Variants: Zones 1 to 64 or Zones 65 to 128
255 Zone LED Display Module (Double Extension Chassis)
Marketing Plans 2000
Excel Life Safety
Marketing Plans 2000
Excel Life Safety
Degraded mode of operation
Enhanced LIB (parallel CPUs)
Loop powered sounders (ABS4, IBS3, ANS4, AWS3)
Loop powered beam detectors (LPB-500, LPB-620)
Menu driven point/data access
Multi-level operator password control
Marketing Plans 2000
Excel Life Safety
Adjustable alarm & fault verification delay
Two-stage alarm operation
Marketing Plans 2000
Excel Life Safety
Key Functions (continued)
Powerful Control-by-Event (CBE)
Output device test
Daily high test
Time of day functions
Up to 1584 devices
Up to 255 zones
Up to 7A PSU
Up to 31 repeaters
600 event history log
rated @ 30Vdc/1A
rated @ 30Vdc/1A
Marketing Plans 2000
Excel Life Safety
Maximum 8 panels
Marketing Plans 2000
Excel Life Safety
Reset
Silence/Re-sound
Mute
Evacuate
Error checking and correction
Up to 158,400 devices
Up to 25,500 zones
Up to 700A PSU
Bldg.3
Bldg.2
Bldg.1
Bldg.4
Minimum training required
Peer-to-peer network
Windows based
System-wide programming
Level 3: Code 2 - Level 2 + Configuration menus
Level 3A: Code 3 - Level 3 + Advanced Configuration
Panel settings
Auto-learn facility
Loop/Device configuration
Network configuration
User Menu
C o n f i g u r a t i o n (E n t e r L e v e l 3 P a s s c o d e)
Marketing Plans 2000
Excel Life Safety
Easy-to-use Test Mode
Either Tested or Not Tested is highlighted for that device.
Use to scroll through device descriptions.
LED ON for 5sec
F I R E
B R E A K G L A S S
P R E S S H E R E
Marketing Plans 2000
Excel Life Safety
User Menu - Examples
Lamp Test checks all panel LED’s, Buzzer, L.C.D. & Contrast adjustment
Marketing Plans 2000
Excel Life Safety
User Menu - Examples
Marketing Plans 2000
Excel Life Safety
2: Zone Text Editor
3: Panel Text Editor
5: Network Configuration
6: Panel Settings
Marketing Plans 2000
Excel Life Safety
Configuration Menu - 2
Loop Device Configuration
Marketing Plans 2000
Excel Life Safety
Configuration Menu - 3
Marketing Plans 2000
Excel Life Safety
Configuration Menu - 4