DOC.NO.:DHT - 1011 - 003SHT :
ITEM NO:120-8-216 ST 20-8
2 nd STAGE GAS COOLER
ATTACHEMENT OF INLET/OUTLET NOZZLES TO HEADER
PLATES /MATING NOZZLES AS PER FIGURE UW 16.1 ( a ).
= 10.97 mm
t = 28 mm
=
= 10.97
=
= 6mm
Fillet leg =
= 8.48mm < provided fillet leg of 9 mm.
HENCE SATISFACTORY
ATTACHEMENT OF COUPLINGS TO HEADER PLATES
= 8.89 mm
t = 28 mm
=
= 8.89
=
= 6mm
Fillet leg =
= 8.48mm < provided fillet leg of 9 mm.
HENCE SATISFACTORY
OF
tn
tmin Smaller of 19mm or Minimum of tn & t
tc Smaller of 6mm or 0.7 x tmin
tc/sin 45 o
MATING NOZZLES AS PER FIGURE UW 16.1 ( a ).
tn
tmin Smaller of 19mm or Minimum of tn & t
tc Smaller of 6mm or 0.7 x tmin
tc/sin 45 o