Upload
hathuy
View
212
Download
0
Embed Size (px)
Citation preview
Getting Started
Wave Pump Installation
For step-by-step video instructions, visit our website at www.current-usa.com/videos
Before Installation & Overview
Safety Warnings and Guidelines
Quick Start Guide
www.current-usa.com
Wave Pump Kit
THANK YOUFor Getting in the LOOP
Follow all safety instructions andwarnings included with this product.
Magnet Attachment
Cable Wrap
Pump Prefilter(optional)
STEP 1Choose a mounting location inside the aquarium vertical wall for your pump. Clean location of anydirt, algae or calcium deposits.
STEP 2Cut 6" of included cable wrap and install aroundinside pump cable by wrapping it around the cord.
STEP 3Carefully separate magnet from pump by slidingor turning magnet (don't pull). Place pump in tankand attach using outer magnet. Swivel and adjust pump to optimal position. Slide optional pumpprefilter over front of pump.
TIP: Cable wrap protects the pump cable from inverts that can damage
cord, pump prefilter protects the impeller from large debris & inverts.
FLOW
FREQUENCY
LOCK ModeMain / Secondary Pump
PUMP
Rate Display
Displays which pump is inprogramming mode.
LED ON = Secondary PumpLED OFF = Primary Pump
Displays if the Flow (velocity) is being shown on the rate display
Displays FLOWor FREQUENCY
Each LED = 10% FLOW or duration
Displays if the Frequency (duration) is being shown on the rate display
LED ON = LockedLED OFF = Unlocked
Flow ModeSRE = Stream/SteadySUR = Surge/GyrePUL = Wave/Pulse
FLOW
FLOW
FREQ
FREQ
Main On/Off
Pump 1, Primary Wave Pump
Pump 2, Secondary Wave Pump
Pump 3, Flow/Stream Mode Only
Primary/Secondary Pump
Stream / Steady Flow Mode
Surge Gyre Mode
Wave / Pulse Mode
Lock/Unlock Key
Increase / Decrease
Increase / Decrease Frequency
123
TM
TM
LOCK
FEED
WAVE
1
2
3
LOCK
FEEDFEED Mode
SURGE
STREAM P/S
FLOW
FLOW
FREQ
FREQP/S
STREAM
SURGE
WAVE
Flow Rate
eFlux wave pumps create a tremendous amount of water flow. DO NOT install pump where the strong current can harm corals or animals.
Do not install pump close to the sand bed where it can stir or suck up debris.
eFlux wave pumps can produce powerful waves in both surge and wave mode. Ensure your tank is designed forwave pumps and ensure pumps are mounted low enough not to push water out of the aquarium.
Magnet assembly is powerful. Be cautious not to causeinjury to fingers.
Keep out of reach of children.
Never let pump run dry or out of water.
Always disconnect from power for cleaning or service.
Ensure only to use 24V DC power supply plugged into a GFCI approved outlet with drip loop installed.
Please visit www.current-usa.com for warranty information.
Follow all safety instructions andwarnings included with this product.
LED Display & Manifold HUB Installation
STEP 6
Choose a clean, dry location to mount manifold HUB and wave pump LED display. Screw mountingclips for HUB and LED display into stand location.Slide HUB and wave pump LED display intomounting clips.
STEP 4
Before connecting cables, please review the following specifications and connections:
Choose Flow Mode
STEP 8
Installation for Orbit Marine PRO
P1P2P3
Pump #1Power DC Input
Pump #2Power DC Input
Pump #3Power DC Input
Pump #2Pump Connection
Pump #3Pump Connection
Port#1Port#2
Port#3Port#4
Pump #1Pump Connection
Communication LEDIndicator Light
MicroUSB Ports
Pump Connections:P1 Pump#1:
Main/Primary Wave Pump P2 Pump#2:
Secondary (Gyre) Wave PumpP3 Pump#3:
Steady/Stream Wave Pump**Operates only in stream modeMicro USB Ports:Port#1= Communications Port#2= LED Display ONLYPort#3= CommunicationsPort#4= Communications
Max. Pump DC Inputs Voltage: 24V DCMax. DC Input per Channel: 72w@24VDCMax. DC Output per Channel: 60w@24VDC
Step 5 Connect cables in the following order:a. LED Display micro USB cable into Port#2b. IR Sensor micro USB cable into Port#1c. eFlux Wave Pump into P1 Pump Connectiond. 24V DC cable into P1 Power DC input
A
B
C
D
Plug 24V DC transformer into GFCI outlet. IndicatorLED light will turn on. Use velcro wraps for cables.
AC PowerGFCI Outlet24VDC
Transformer
eFlux Wave Pump LED Display
P1P3 P2
LCK P/S SRE SUR PUL FRE FLO
IR Sensor
Port#1
Port#2
A
B
C
D
Programming & Control Instructions
0 1 2
TM
TM
LOCK
MainPower
STREAM
SURGE
WAVE
FEEDP/S
FLOW
FLOW
FREQ
FREQ
FLOW
FLOW
STREAM SURGE WAVE
FREQ
FREQ
POWER - Press the Main Power key to LED display andall pumps ON/OFF. To turn individual pumps ON/OFF, press the designated pump key and hold for 5 seconds. ! " #
LOCK
FEED
TIME
STREAM/STEADY MODE
0
100%
50%
Flow
Steady, constant flow streamadjustable from 0-100%. Mimicsstrong water currents, providesexcellent circulation tank wide.
Alternates a slow ramp up/downMimics surging water currentsFlow adjustable from 0-100%,frequency 10-90 seconds.
SURGE/GYRE FLOW
0
100%
50%
FLOW
FREQUENCY
Max. FlowON
OFF
Alternates a short pulsing actionMimics wave type action. Flowadjustable from 0-100%, frequency 0.3 to 7 seconds.
WAVE/PULSE MODE
0
100%
50%
FLOW
TIME
ON
OFF
Max. FLOW
Use caution when operating
pumps in wave or surge mode
LOCK/UNLOCK - Press the LOCK key to lock settings.LCKwill display on display. To unlock settings, press LOCK key for 5 seconds. NOTE: Remote will ONLY work when unlocked.
LOCK
FEED - Press the FEED key to temporarily turn pumps off for feeding. Pumps will return to normal setting after 10 min.
STEP 10
Press designated pump key to program specific pump. Pump # will light on display.
Press designated mode key to
choose flow mode. Flow mode will lighton display.
Press flow keys to change the flowspeed. 10% increment will light on display.
Press frequency keys to change the frequency in SURGE or WAVE mode. Rateof frequency will light on display.
! " #
GYRE - Press Pump#2 key then press the P/S key to designate Pump#2 as a primary or secondary pump. When Pump#2 is in secondary mode it will run the opposite of Pump#1 program (operating in tandem).
Press Pump#2 key and press P/S key again to return Pump#2 to primary (independent mode).
"
P/S
STEP 7Remove clear tab from remote. Press main power key. Pump will turn on in default setting Stream MODE, 100% flow.
Main Pump Controls
STEP 9
Program Flowrate and Flow Mode
"
P/S