20
N L AK E S HO R E B L VD W F OU R T H S T T H I R D S T S E C OND S T F I R S T S T L AK E S HO R E D R S A ND B E A C H R D D W I GH T AV E A L B AN I S T R OYA L YO R K R D E A S T B OU R N E CR E S DA R T M OU T H CR E S S U SS E XD R L AK E CR E S L AK E CR E S W H E A T F I EL D R D S Y MON S S T QU EE N S AV E H I LL S I D E AV E NO RR I S CR E S DOUG L A S B L VD MI LE S R D S U MME R H I LLR D A LLE N A V E MI MI C O AV E P R I MR O S E A V E S U P E R I O R AV E S U P E R I O R AV E A L B E R TAV E S T AN LE YAV E S T AN LE Y AV E B U R L I N G T ON S T L AK E S HO R E B L VD W V I C T O R I AS T L OU I S AS T A LE XAN D E R S T B L VD MA P LE ENGINEERING AND CONSTRUCTION SERVICES LOCATION PLAN G1 DRAWING NUMBER: Water GENERAL MANAGER TORONTO WATER LOU DI GIRONIMO ENGINEERING AND CONSTRUCTION SERVICES MICHAEL D'ANDREA, P. ENG. EXECUTIVE DIRECTOR 15ECS-LU-06TT 1058-2013-19-1 1:5000 LAKE SHORE SANITARY TRUNK SEWER AND MAINTENANCE HOLES REHABILITATION L AK E S HO R E B L VD W M I M I C O P . S . MU RR I E S T L AK E CR E S H E MAN S T B I R MI NGHA M S T L AK E ON T A R I O L AK E ON T A R I O J U L Y 22 , 2015 BETWEEN MH324-028-1 AND MH324-001-1 ISSUED FOR TENDER

Water - Toronto · 1 07-22-2015 1058-2013-19-2 g2 m.b. n l a k e s h o r e b l v d w fourt hst third st seco ndst first st l a k e s h o r e d r sand b each r d dwigh t ave a l b

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • N

    LA

    KE S

    HO

    RE B

    LV

    D W

    FOURTH ST

    THIRD ST

    SECON

    D ST

    FIRST

    STLAKE SHORE DR

    SAND B

    EACH R

    D

    DWIGH

    T AVE

    ALB

    ANI S

    T

    ROYAL YO

    RK RD

    EASTBOURNE CRES

    DARTMOUTH CRES

    SUSSEX D

    R

    LA

    KE C

    RES

    LAKE C

    RES

    WHEAT

    FIELD

    RD

    SY

    MO

    NS S

    T

    QUEEN

    S AVE

    HIL

    LSID

    E A

    VE

    NO

    RRIS C

    RES

    DO

    UG

    LAS B

    LV

    DMILES R

    D

    SU

    MM

    ER

    HIL

    L R

    D

    ALLE

    N A

    VE

    MIMIC

    O A

    VE

    PRIM

    ROSE A

    VE

    SUPE

    RIO

    R A

    VE

    SUPERIO

    R A

    VE

    ALB

    ERT A

    VE

    STANLEY AVE

    STANLEY AVE

    BU

    RLIN

    GTO

    N S

    T

    LAKE SHORE BLVD W

    VICTORIA ST

    LO

    UIS

    A S

    T

    ALE

    XA

    NDER S

    T

    BLV

    DM

    APLE

    ENGINEERING AND CONSTRUCTION SERVICES

    LOCATION PLAN

    G1DRAWING

    NUMBER:

    Water

    GENERAL MANAGER

    TORONTO WATER

    LOU DI GIRONIMO

    ENGINEERING AND CONSTRUCTION SERVICES

    MICHAEL D'ANDREA, P. ENG.

    EXECUTIVE DIRECTOR

    15ECS-LU-06TT

    1058-2013-19-1

    1:5000

    LAKE SHORE SANITARY TRUNK SEWER AND MAINTENANCE HOLES REHABILITATION

    LAKE SHORE BLVD W

    MIMICO P.S.

    MU

    RRIE S

    T

    LA

    KE C

    RES

    HE

    MA

    N S

    T

    BIR

    MIN

    GH

    AM S

    T

    LAKE ONTARIO

    LAKE ONTARIO

    JULY 22, 2015

    BETWEEN MH324-028-1 AND MH324-001-1

    ISSUED FOR TENDER

  • DRAWING DESCRIPTIONCITY DWG No.

    2

    3

    4

    1

    5

    6

    7

    8

    9

    10

    11

    12

    27

    28

    29

    13

    15

    14

    30

    17

    18

    21

    24

    20

    26

    32

    31

    33

    34

    25

    16

    DRAWING INDEX

    DISCIPLINE

    TITLE PAGE1058-2013-19-1 G1

    ITEM No.

    1058-2013-19-2 G2 DRAWING INDEX AND KEY MAP

    1058-2013-19-3 G3

    1058-2013-19-4 C1

    1058-2013-19-5 C2

    C3

    C4

    C5

    C6

    C7

    C8

    C9

    1058-2013-19-6

    1058-2013-19-7

    1058-2013-19-8

    1058-2013-19-9

    1058-2013-19-10

    1058-2013-19-11

    1058-2013-19-12

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    1058-2013-19-2 G2

    M.B.

    N

    LA

    KE S

    HO

    RE B

    LV

    D W

    FOURTH ST

    THIRD ST

    SECON

    D ST

    FIRST

    ST

    LAKE SHORE DR

    SAND B

    EACH R

    D

    DWIGH

    T AVE

    ALB

    ANI S

    T

    ROYAL YO

    RK RD

    EASTBOURNE CRES

    DARTMOUTH CRESSUSSEX D

    R

    LA

    KE C

    RES

    LAKE C

    RES

    WHEAT

    FIELD

    RD

    SY

    MO

    NS S

    T

    QUEEN

    S AVE

    HIL

    LSID

    E A

    VE

    NO

    RRIS C

    RES

    DO

    UG

    LAS B

    LV

    DMILES R

    D

    SU

    MM

    ER

    HIL

    L R

    D

    ALLE

    N A

    VE

    MIMIC

    O A

    VE

    PRIM

    ROSE A

    VE

    SUPE

    RIO

    R A

    VE

    SUPERIO

    R A

    VE

    ALB

    ERT A

    VE

    STANLEY AVE

    STANLEY AVE

    BU

    RLIN

    GTO

    N S

    T

    LAKE SHORE BLVD W

    VICTORIA ST

    LO

    UIS

    A S

    T

    ALE

    XA

    NDER S

    T

    1058-2

    013-19-4-C

    1

    1058-2013-19-7-C4

    1058-2013-19-8-C5 1058-2013-19-9-C6 1058-2013-19-10-C71058-2013-19-11-C8

    1058-2013-19-27

    1058-2013-19-28

    1058-2013-19-29

    1058-2013-19-30

    C24

    C25

    C26

    C27

    TRAFFIC MANAGEMENT PLAN (1)

    TRAFFIC MANAGEMENT PLAN (2)

    TRAFFIC MANAGEMENT PLAN (3)

    TRAFFIC MANAGEMENT PLAN (4)

    1058-2

    013-1

    9-5-C

    2

    1058-2013-19-12-C9

    BLV

    DM

    APLE

    1058-2013-19-6-C3

    KEY MAP1:5000

    LAKESHORE SANITARY TRUNK SEWER

    REHABILITATION

    1058-2013-19-13 C10

    1058-2013-19-14 C11

    1058-2013-19-15 C12

    1058-2013-19-16 C13

    1058-2013-19-17 C14

    1058-2013-19-18 C15

    1058-2013-19-19 C16

    1058-2013-19-20 C17

    1058-2013-19-21 C18

    1058-2013-19-24 C21

    1058-2013-19-25 C22

    1058-2013-19-26 C23

    1058-2013-19-31 C28

    1058-2013-19-32 C29

    1058-2013-19-33 C30

    1058-2013-19-34 C31

    19

    C19

    C2023

    22 1058-2013-19-22

    1058-2013-19-23

    MAINTENANCE HOLE SCHEDULE (1)

    MAINTENANCE HOLE SCHEDULE (2)

    MAINTENANCE HOLE SCHEDULE (3)

    HE

    MA

    N S

    T

    MU

    RRIE S

    T

    LA

    KE C

    RES

    BIR

    MIN

    GH

    AM S

    T

    LAKE ONTARIO

    LAKE ONTARIO

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    AS SHOWN

    1058-2

    013-19-27-C2

    4

    1058-2013-19-28-C25

    1058-2013-19-29-C261058-2013-19-30-C27

    1058-2

    013-19-34-C3

    1

    1058-2013-19-35-C32

    INDEX AND KEY MAP

    PLAN

    GENERAL NOTES, ABBREVIATIONS AND LEGEND

    35

    37

    1058-2013-19-35 C32

    1058-2013-19-37 C34

    1058-2013-19-36-C331058-2013-19-37-C34

    TRAFFIC MANAGEMENT PLAN (5)

    1058-2

    013-1

    9-3

    1-C

    28

    JULY 22, 2015

    36 1058-2013-19-36 C33

    MISCELLANEOUS DETAILS

    MAINTENANCE HOLE REPAIR DETAILS (2) - TYPE 3

    MAINTENANCE HOLE REPAIR DETAILS (3) - TYPE 4

    MAINTENANCE HOLE REPAIR DETAILS (4) - TYPE 5

    MAINTENANCE HOLE REPAIR DETAILS (6) - TYPE 8

    MAINTENANCE HOLE REPAIR DETAILS (7) - TYPE 9

    MAINTENANCE HOLE REPAIR DETAILS (10)

    MAINTENANCE HOLE REPAIR DETAILS (11)

    BYPASS PUMPING STAGING, PHASE 1

    BYPASS PUMPING STAGING, PHASE 1 & 2

    BYPASS PUMPING STAGING, PHASE 3

    MAINTENANCE HOLE REPAIR DETAILS (1) - TYPES 1 AND 2

    MAINTENANCE HOLE REPAIR DETAILS (5) - TYPES 6 AND 7

    MAINTENANCE HOLE REPAIR DETAILS (8) - TYPES 10 AND 11

    MAINTENANCE HOLE REPAIR DETAILS (9) - TYPES 12 AND 13

    BYPASS PIPING AND PAVEMENT RESTORATION DETAILS

    MH324-028-1 to MH324-025A-1 - PLAN AND PROFILE

    MH324-025-1 to MH324-024-1 - PLAN AND PROFILE

    MH324-023-1 to MH324-021-1 - PLAN AND PROFILE

    MH324-020-1 to MH324-019-1 - PLAN AND PROFILE

    MH324-018-1 to MH324-017-1 - PLAN AND PROFILE

    MH324-016-1 to MH324-014A-1 - PLAN AND PROFILE

    MH324-013-1 to MH324-007-1 - PLAN AND PROFILE

    MH324-006-1 to MH324-004-1 - PLAN AND PROFILE

    MH324-003-1 to MH324-001-1 - PLAN AND PROFILE

    BYPASS PUMPING STAGING, PHASE 4

    TRAFFIC MANAGEMENT PLAN (6)

    TRAFFIC MANAGEMENT PLAN (7)

    38

    39

    1058-2013-19-38

    1058-2013-19-39

    C35

    C36

    ISSUED FOR TENDER

  • M.D. 15ECS-LU-06TT

    1 07-22-2015

    1058-2013-19-3 G3

    M.B.

    LAKESHORE SANITARY TRUNK SEWER

    REHABILITATION

    GENERAL NOTES

    LEGISLATION, REGULATION AND CODES

    CONSTRUCTION NOTES

    ADVERSELY AFFECT ADJACENT LANDS.ALL AREA GRADING AND RESULTING DRAINAGE PATTERNS SHALL NOT5.

    THE CONTRACTOR'S EXPENSE.ACCURACY AS THE ORIGINAL MONUMENT(S) IN A TIMELY MANNER, AND ATOF THE WORKS. PERFORM THE WORKS TO PRODUCE THE SAME LEVEL OFPOINTS, AND STAKES WHICH ARE DISTURBED OR DESTROYED AS A RESULTMAINTAIN, RELOCATE, OR REPLACE EXISTING SURVEY MONUMENT, CONTROL8.

    UTILITY SEPARATIONS PRESCRIBED BY UTILITY OWNERS ARE TO BE ADHERED TO.PROTECT ALL EXISTING UTILITIES. HAND EXCAVATION REQUIREMENTS AND9.

    STANDARDS.ACCORDANCE WITH ALL APPLICABLE AND CURRENT CITY OF TORONTORESTORATION TO THE SITE MUST BE CONSTRUCTED AND CARRIED OUT INAND TO THE SATISFACTION OF THE CONTRACT ADMINISTRATOR. ALLRESTORE ALL DISTURBED AREAS TO THE ORIGINAL CONDITION OR BETTER6.

    CONTACT INFORMATION

    ORIGINAL DATA SOURCE

    ENVIRONMENTAL NOTES

    VERTICAL DATUM 1929 (NGVD 29). NORTH AMERICAN DATUM 1927 (NAD 27), AND VERTICAL DATUM: NATIONAL GEODETIC

    HORIZONTAL DATUM: 3-DEGREE MODIFIED TRANSVERSE MERCATOR (MTM), ONTARIO ZONE 10,1.

    NECESSARY CHANGES.AND THE CONTRACT ADMINISTRATOR SHALL NOTIFY THE CITY OF THE AND THE LAYOUT SHALL BE REPORTED TO THE CONTRACT ADMINISTRATOR PRIOR TO CONSTRUCTION. ANY DISCREPANCIES BETWEEN THE DRAWINGS ALL SURVEY POINTS SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR 3.

    CONFIRMING CLEARANCE FOR CONSTRUCTION.UTILITIES AND PIPE LINES, STRUCTURES AND FACILITIES AS REQUIRED,CONFIRM EXISTING DIMENSIONS, ELEVATIONS AND LOCATION OF ALL BASED UPON RECORD DRAWINGS AND INFORMATION. CONTRACTOR TO EXISTING UTILITIES AND PIPE LINES SHOWN IN APPROXIMATE LOCATION 4.

    STRUCTURES, OR TOP OF SIDEWALK UNLESS OTHERWISE NOTED.ELEVATIONS GIVEN ARE FINISHED GRADE, TOP OF PAVEMENT, TOP OF 5.

    REGION CONSERVATION AUTHORITY.BY THE CONTRACT ADMINISTRATOR AND THE TORONTO AND APPROVED

    NATIVE/NON-INVASIVE SPECIES UPON COMPLETION OF THE WORK ASWITHALL DISTURBED VEGETATED AREAS SHALL BE STABILIZED AND RESTORED7.

    AND ELEVATIONS AND REPORT ANY DISCREPANCIES TO THE CONTRACT ADMINISTRATOR.CONTRACTOR TO FIELD VERIFY SEWER AND ALL MAINTENANCE HOLE DIMENSIONS 16.

    AND ADJUST WORK PLAN ACCORDINGLY PRIOR TO BEGINNING CONSTRUCTION.THOSE SHOWN. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PROVIDED BY FIELD SURVEY DATED 2013. EXISTING CONDITIONS MAY VARY FROM SOURCE OF TOPOGRAPHY SHOWN ON THE DRAWINGS ARE BASE MAPS 6.

    AND WATERMAINS MANUAL.6, MATERIAL SPECIFICATIONS FROM DESIGN CRITERIA FOR SEWERSMATERIAL/MANUFACTURER SPECIFICATIONS AS REQUIRED BY CHAPTERAPPURTENANCES, SHALL BE ACCORDING TO CITY OF TORONTOALL MATERIAL FOR SEWER, FORCEMAIN, WATERMAIN, HYDRANTS AND13.

    OF THE CONTRACT ADMINISTRATOR.OF CONSTRUCTION AND APPROPRIATE ACTION TAKEN TO THE SATISFACTIONDRAWINGS MUST BE REPORTED TO THE CITY PRIOR TO COMMENCEMENTANY DISCREPANCIES BETWEEN SITE CONDITIONS AND CONSTRUCTION15.

    EXPRESSED IN MILLIMETRES (mm) UNLESS OTHERWISE NOTED.ALL DIMENSIONS ARE EXPRESSED IN METRES (m) AND PIPE SIZES ARE 18.

    ALL ELEVATIONS ARE IN METRES (m) UNLESS NOTED OTHERWISE.19.

    ADMINISTRATOR AND THE CITY.GENERATORS SHALL BE MUFFLED TO THE SATISFACTION OF THE CONTRACT BYPASS PUMPING SHALL RUN ON A CONTINUNOUS BASIS WHEN REQUIRED, 7.

    DAYS PRIOR TO THE COMMENCEMENT OF ANY WORK.ADMINISTRATOR AND CITY STAFF IS TO BE HELD A MINIMUM OF FIVE WORKINGWORK. A PRE-CONSTRUCTION COORDINATION MEETING WITH CONTRACTNOTICE TO SPECIFY THE ANTICIPATED DATE OF COMMENCEMENT OF THEPROVISIONS HEREOF AND GIVING 10 WORKING DAYS PRIOR WRITTENPORTION OF THE INFRASTRUCTURE WORK IN ACCORDANCE WITH THE SCHEDULE, APPROVED TRAFFIC STAGING PLANS AND PERMITS FOR SUCHOBTAINED APPROVED CONSTRUCTION DRAWINGS, APPROVED PROJECTNO PORTION OF THE WORK SHALL BE CARRIED OUT WITHOUT FIRST HAVING1.

    AND DEPTH OF ANY UTILITY AND SHALL BE LIABLE FOR ALL OR ANY DAMAGE.THE CONTRACTOR SHALL SATISFY THEMSELVES AS TO THE ACTUAL LOCATION REFERENCE PURPOSES ONLY AND IN GENERAL ARE SHOWN AT NOMINAL DEPTHS. ALL EXISTING UTILITIES SHOWN ON DRAWINGS (PLAN AND PROFILE) ARE FOR 14.

    LEAVING THE SITE "UNTREATED."PILING OPERATIONS AND SHALL BE LOCATED TO PREVENT SURFACE RUNOFF FROM DRAWINGS ARE TO BE IN PLACE PRIOR TO INITIATION OF EXCAVATION AND STOCK SEDIMENTATION AND EROSION CONTROLS IN ACCORDANCE WITH THE CONTRACT 2.

    CONTRACTOR (AND AFTER ANY STORM EVENT) AND CLEARED OR REPLACED, AS REQUIRED.ALL SEDIMENTATION AND EROSION CONTROLS ARE TO BE INSPECTED REGULARLY BY THE 3.

    OF THE CONTRACT ADMINISTRATOR.BE REMOVED FOLLOWING CONSTRUCTION AND AREAS RESTORED TO THE SATISFACTION ALL EROSION CONTROL AND TEMPORARY ACCESSES, STRUCTURES AND FACILITIES TO 8.

    REMOVE SILT FROM DEWATERING AND OTHER PUMPING OPERATIONS PRIOR TO DISCHARGE.9.

    GEOTECHNICAL AND HYDROLOGICAL REPORTS

    SPECIFICATION IS AVAILABLE.CITY OF TORONTO, BE USED WHERE NO CITY STANDARD ORAND SPECIFICATIONS MAY, SUBJECT TO THE APPROVAL OF THEAND SPECIFICATIONS. ONTARIO PROVINCIAL STANDARD DRAWINGSACCORDING TO THE LATEST CITY OF TORONTO STANDARD DRAWINGSALL WORK WITHIN THE CITY RIGHT-OF-WAY SHALL BE CONSTRUCTED1.

    DEEMED TO BE THE CONSTRUCTOR AS DEFINED IN THE ACT.CONSTRUCTION PROJECTS. THE GENERAL CONTRACTOR SHALL BEOCCUPATIONAL HEALTH AND SAFETY ACT AND REGULATIONS FORALL WORK SHALL BE COMPLETED ACCORDING TO THE CURRENT2.

    BOOK 7: TEMPORARY CONDITIONS FIELD EDITION.SHALL BE ACCORDING TO THE CURRENT ONTARIO TRAFFIC MANUALALL TEMPORARY TRAFFIC CONTROL AND SIGNAGE DURING CONSTRUCTION3.

    UTILITY CUTS. CONSENT REQUIREMENTS, APPENDIX D, TEMPORARY REPAIRS TOTEMPORARY REPAIRS TO UTILITY CUTS WILL BE AS PER MUNICIPAL4.

    PERMITS FROM THE CITY'S RIGHT OF WAY MANAGEMENT UNIT.WAY THE CONTRACTOR SHALL OBTAIN ALL NECESSARY ROAD OCCUPANCYPRIOR TO COMMENCING ANY WORK WITHIN THE MUNICIPAL RIGHT OF5.

    BE THE RESPONSIBILITY OF THE CONTRACTOR.ANY DAMAGE TO PROPERTY ADJACENT TO THE CONSTRUCTION SITE SHALL3.

    TO THE CITY.PROPERTY OWNER IS OBTAINED AND SUBMITTED IN A FORMAT ACCEPTABLESHALL BE UNDERTAKEN UNLESS WRITTEN AGREEMENT WITH THE ADJACENTNO ALTERATIONS TO EXISTING BOUNDARY ELEVATIONS OR ADJACENT LANDS4.

    NOISE BYLAW AND RAVINE AND NATURAL FEATURE PROTECTION BY-LAW.ALL CONSTRUCTION ACTIVITY SHALL COMPLY WITH CITY OF TORONTO6.

    SHALL BE SUPPORTED ACCORDING TO CITY OF TORONTO DRAWING T-1007.01-4.ALL EXISTING WATERMAINS AND SEWER PIPES LARGER THAN 300 mm DIAMETER 17.

    EQUIVALENT.GRADED AND SODDED. FILTER FABRIC FOR SILT CONTROL TO BE TERRAFIX 270R OR APPROVED TIME AS THE CURBS ARE CONSTRUCTED AND THE BOULEVARDS ARE SODDED OR BACKYARDS SILT TRAPS ARE SHALL BE CLEANED REGULARLY AND ARE NOT TO BE REMOVED UNTIL SUCH FILTER FABRIC SILT TRAPS SHALL PLACED UNDER GRATES ON ALL CATCHBASINS TO TRAP SEDIMENT. 6.

    ANY FLOODING RESULTING FROM BLOCKED OR IMPAIRED DRAINAGE SYSTEMS.MAINTAINED AND REPLACED WHEN NECESSARY. CONTRACTOR SHALL BE RESPONSIBLE FOR EXISTING CATCH BASINS SHALL BE WRAPPED IN FILTER CLOTH WHICH WILL BE MONITORED, 7.

    AREAS SHALL BE APPROVED BY TRCA.IN THE FLOODPLAIN OR WITHIN 30 m OF WATERCOURSE. EQUIPMENT STORAGE AND LAYDOWN ONSITE STORAGE: EQUIPMENT, MACHINERY, SITE TRAILERS CANNOT TYPICALLY BE STORED 13.

    ABBREVIATIONS LEGEND

    SANITARY MAINTENANCE HOLE

    EXISTING TREE TO BE REMOVED

    353

    CIRCULAR CATCH BASIN

    BUSH (CONIFEROUS)

    CUT CROSS

    HANDWELL (VARIOUS)

    FIRE HYDRANT AND VALVE

    LIGHT STANDARD

    STORM SEWER MAINTENANCE HOLE COVER

    PARKING METER

    TV/ELECTRIC PEDESTAL

    SANITARY MAINTENANCE HOLE COVER

    SHRUB

    SIB OR IB

    SWAMP

    WATER VALVE CHAMBER

    VALVE

    BENCH MARK

    BOREHOLE

    BRASS CAP

    GAS VALVE

    GAS VENT

    FENCE GATE

    GUY POLE

    HORIZONTAL CONTROL MARKER

    HEDGE

    MARSH

    POINT/TICK

    EXISTING STORM SEWER

    EXISTING WATERMAIN

    EXISTING SANITARY SEWER

    SANITARY SEWERPROPOSED XXmm

    XXmm SANITARY SEWER

    XXmm STORM SEWER

    XXmm WATERMAIN

    CPR

    WV

    G

    HW

    LS

    PM

    DOUBLE CATCH BASIN

    SINGLE CATCH BASIN

    SIGN

    TREE STUMPSTUMP

    PROPOSED TREE

    TREE TO BE RETAINED AND PROTECTEDTREE IDENTIFICATION NUMBER

    MINIMUM TREE PROTECTION ZONE (TPZ)

    TREE CANOPY DRIPLINE

    DECIDUOUS TREE

    CONIFEROUS TREE

    GATE VALVE

    REGIONAL FLOOD LINE

    EASEMENT LINE

    THE SATISFACTION OF THE CITY OF TORONTO.COMMENCEMENT OF CONSTRUCTION AND APPROPRIATE ACTION TAKEN TOBE REPORTED TO THE CONTRACT ADMINISTRATOR PRIOR TO THE ANY DISCREPANCIES BETWEEN SITE CONDITIONS AND THE DRAWINGS MUST 2.

    MEASURES TO BE KEPT ON SITE AND USED AS NECESSARY.AUTHORITY ENFORCEMENT OFFICE TO BE IMMEDIATELY CONTACTED. ADDITIONAL ESC MINIMIZE POTENTIAL ECOLOGICAL IMPACTS AND THE TORONTO REGION CONSERVATIONSUBSTANCE, THEN ALTERNATIVE MEASURES MUST BE IMPLEMENTED IMMEDIATELY TO MEASURES ON THE PLANS ARE NOT EFFECTIVE IN PREVENTING THE RELEASE OF A DELETERIOUS MINIMIZE SEDIMENT LADEN RUNOFF FROM LEAVING THE WORK AREA. IF THE PRESCRIBED STATIC AND MAY NEED TO BE UPGRADED/AMENDED AS SITE CONDITIONS CHANGE TO THE EROSION AND SEDIMENT CONTROL STRATEGIES OUTLINED ON THE PLANS ARE NOT 4.

    REFUELING AND MAINTENANCE MUST BE CONDUCTED IN DESIGNATED AREAS.SUBSTANCES INTO NEARBY DITCHES, SWALES, STORM DRAINS OR WATERBODIES. VEHICLE TO PREVENT ENTRY OF PETROLEUM PRODUCTS, DEBRIS, CONCRETE OR OTHER DELETERIOUS ALL CONSTRUCTION ACTIVITIES INCLUDING MAINTENANCE PROCEDURES WILL BE CONTROLLED 5.

    WEEKLY BASIS BEFORE LEAVING THE SITE FOR WEEKENDS.NECESSARY) OF ROADS ADJACENT TO THE PROJECT. IN ADDITION CLEAN ALL ROADS ON PROVIDE DUST CONTROL AT ALL TIMES INCLUDING THE MAINTENANCE AND CLEANUP (WHEN 10.

    DIRT TRACKING ONTO ROADS.CLEAN OFF TRUCKS AND EQUIPMENT PRIOR TO LEAVING THE SITE TO PREVENT MUD AND 11.

    PROVIDE SPILL CONTAINMENT CONTROL.12.

    48 HOURS OF INSPECTION OR BOTH.SEDIMENT CONTROL MEASURES SHALL BE REPAIRED OR REPLACED WITHIN ENTRY OF SEDIMENT INTO THE WATERWAY AND SEWERS. ALL DAMAGED EROSION AND PRIOR TO, AND MAINTAINED DURING CONSTRUCTION PHASES, TO PREVENT EROSION AND SEDIMENT CONTROL (ESC) MEASURES SHALL BE IMPLEMENTED 1.

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    NO SCALE

    RIGHT-OF-WAY

    PROPERTY LINE

    CPR/CNR MAINTENANCE HOLE COVER

    GENERAL NOTES, ABBREVIATIONS AND LEGEND

    NOTES

    CH2M HILL, DATED APRIL 2015.FOR GEOLOGICAL AND HYDROLOGICAL INFORMATION REFER TO REPORT PREPARED BY 1.

    COMMENCING CONSTRUCTION. (416-393-3302 OR [email protected]) AT LEAST 10 WORKING DAYS PRIOR TO OF A STREET CLOSURE, THE CONTRACTOR SHALL CONTACT MR. JOHN PRESSERDURING CONSTRUCTION, IN ORDER TO DIVERT ANY TTC SERVICE AS A RESULT 3.

    OR [email protected]) FOR PARKS PERMIT.RECREATION. THE CONTRACTOR SHALL CONTACT JORGE TURE (416-394-5413CONSTRUCTION WORKS IN PARKS FROM THE CITY OF TORONTO PARKS, FORESTRY AND

    THE CONTRACTOR SHALL OBTAIN A PARK ACCESS AGREEMENT FOR THE ACCESS AND

    PARKS PERMIT:5.

    OR [email protected]) AT LEAST 48 HOURS PRIOR TO COMMENCING CONSTRUCTION.LOCATION, THE CONTRACTOR SHALL CONTACT MR. JOHN PROSSER (416-393-3302 TIMES. IN ORDER TO TEMPORARILY RELOCATE ANY TTC BUS OR STREETCAR DURING CONSTRUCTION WHEEL TRANS ACCESS SHALL BE MAINTAINED AT ALL 2.

    TEMPORARY BYPASS PUMPING TRENCH

    JULY 22, 2015

    W.S.L.

    WM

    VB

    US

    TRCA

    TCB

    STS

    STA

    S.S.L.

    SAN

    RD

    RCP

    PVC

    PROP.

    P.E.

    OPSD

    NO

    NTS

    N.S.L.

    M.O.E.

    MIN.

    MH

    I.P.

    I.E.

    I.D.

    HOR

    G.E.

    FRP

    EX

    E.S.L.

    ESC

    DWG

    DS

    DR

    DIA

    D.I.

    DCB

    CONC.

    C.S.P.

    CL

    C.E.

    CB

    ASTM

    ASB CM

    ADMINISTRATOR. SEE DETAIL SHEET C34.TREE PROTECTION TO BE INSTALLED IN LOCATIONS OUTLINED BY THE CONTRACT 11.

    TORONTO WATER INSPECTOR MAY BE PRESENT. 416-392-9334 OR AT [email protected], AT LEAST 48 HOURS PRIOR TO EXCAVATION, SO THAT A CONTRACTOR SHALL NOTIFY TORONTO WATER, DIVISIONAL OPERATIONS SERVICES AT

    DURING THE CONSTRUCTION CLOSE TO AN EXISTING SANITARY TRUNK SEWER, THEDIVISIONAL OPERATIONS SERVICES AT LEAST TWO (2) WEEKS PRIOR TO EXCAVATION. SEWERS" SHALL BE COMPLETED BY THE CONTRACTOR AND RECEIVED BY TORONTO WATER, TORONTO WATER'S FORM "CONSTRUCTION WORK NEAR CITY OF TORONTO TRUNK PRIOR TO ANY CONSTRUCTION ACTIVITY IN THE VICINITY OF A TRUNK SEWER, 4.

    TRAFFIC LIGHT

    REPLACED AT CONTRACTOR'S OWN EXPENSE.DAMAGED AREAS OF PAVEMENT AND SIDEWALKS SHALL BE REMOVED ANDREPAIR ANY DAMAGE DONE TO ROADS AND SITE DURING CONSTRUCTION.10.

    IF DAMAGED DURING CONSTRUCTION AT CONTRACTOR'S OWN EXPENSE.WHETHER SHOWN OR NOT. REPAIR ITEMS TO THEIR ORIGINAL CONDITIONREMOVE OR DEMOLISH ALL ITEMS REQUIRED FOR NEW CONSTRUCTION12.

    FROM THE CITY'S RIGHT-OF-WAY MANAGEMENT UNIT DISTRICT OFFICE.THE CONTRACTOR SHALL APPLY FOR AND OBTAIN A ROAD OCCUPANCY PERMIT PRIOR TO COMMENCING ANY WORK WITHIN THE MUNICIPAL RIGHT-OF-WAY, 1.

    WEST STREET LINE

    WATERMAIN

    VALVE BOX

    UPSTREAM

    TORONTO AND REGION CONSERVATION AUTHORITY

    TEMPORARY CONCRETE BARRIER

    SANITARY TRUNK SEWER

    STATION

    SOUTH STREET LINE

    SANITARY

    RECORD DRAWING

    REINFORCED CONCRETE PIPE

    POLYVINYL CHLORIDE

    PROPOSED

    POLYETHYLENE

    ONTARIO PROVINCIAL STANDARD DRAWING

    NUMBER

    NOT TO SCALE

    NORTH STREET LINE

    MINISTRY OF THE ENVIRONMENT AND CLIMATE CHANGE

    MINIMUM

    MAINTENANCE HOLE OR MANHOLE

    INTERMEDIATE PRESSURE

    INVERT ELEVATION

    IDENTIFICATION

    HORIZONTAL

    GROUND ELEVATION

    FIBERGLASS REINFORCED PLASTIC

    EXISTING

    EAST STREET LINE

    EROSION AND SEDIMENTATION CONTROL

    DRAWING

    DOWN STREAM

    DIMENSION RATIO

    DIAMETER

    DUCTILE IRON

    DOUBLE CATCH BASIN

    CONCRETE

    CORRUGATED STEEL PIPE

    CLASS

    COVER ELEVATION

    CATCH BASIN

    AMERICAN SOCIETY OF TESTING AND MATERIALS

    ASBESTOS CEMENT

    PROPOSED SANITARY SEWER TO BE REHABILITATED

    OF THE UTILITIES AT HIS OWN EXPENSE.UTILITIES IS NEEDED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATION DRAWINGS ARE ESSENTIALLY CORRECT, HOWEVER IF RELOCATION OF EXISTING WITHIN THE LIMITS OF THE WORK PRIOR TO EXCAVATION. IT IS BELIEVED THAT THE EXACT LOCATION AND ELEVATION OF EACH UTILITY AND APPURTENANCES SHALL BE RESPONSIBLE FOR CONTACTING ALL UTILITY OWNERS AND VERIFYING OVERHEAD OR UNDERGROUND UTILITY CONDUITS MAY NOT BE SHOWN. THE CONTRACTOR SANITARY AND STORM SEWERS, WATERMAINS, ELECTRICAL, TELEPHONE, AND OTHER 2.

    ISSUED FOR TENDER

    AFTER THE OPERATIONS FIELD MANAGER'S APPROVAL.NOT THE RESPONSIBILITY OF ENBRIDGE GAS DISTRIBUTION INC. AND CAN ONLY BE DONE OPERATIONS OF OUR ABANDONED GAS PLANT. REMOVAL OF THE ABANDONED GAS PLANT IS [email protected] TO FACILITATE VERIFICATION AND DE-WATERING CHRIS MCGIVERY - FIELD MANAGER, OPERATIONS @ 416-495-5750 OR EMAIL ABANDONED GAS PLANT DURING CONSTRUCTION, THE CONTRACTOR MUST CONTACT CONTRACTOR WILL BE EXPOSING THE ABANDONED GAS PLANT OR HAPPEN TO EXPOSE THE THERE IS AN ABANDONED GAS PLANT IN THE VICINITY OF YOUR PROPOSED WORK. IF THE 6.

  • HW

    HW

    HW

    HW

    HW

    HW

    HW

    HW

    HW

    TT

    T

    T

    T

    TT

    PARKING

    PARKING

    TR

    EE

    D

    AR

    EA

    020770011

    92

    90

    88

    86

    84

    85

    83

    81

    79

    77

    9

    3

    10-12

    17

    2732-2750

    2724

    2722

    97

    57

    91

    W.S.L.

    E.S.L.

    W.S.L.

    E.S.L.9+80

    9+80

    10+00

    10+25

    10+50

    10+75

    11+00

    11+25

    11+50

    11+75

    12+00

    12+25

    12+50

    WV*

    *

    N81.0

    8

    S81.0

    8

    N81.0

    1

    S80.9

    6

    N79.7

    6

    S79.6

    7

    E78.9

    6S78.8

    6

    E80.9

    5

    E79.7

    1

    N78.8

    4

    83.7

    6

    83.7

    5

    83.3

    4

    83.0

    0

    82.6

    9

    82.4

    7

    82.4

    5

    82.3

    0

    82.2

    0

    82.0

    2

    82.0

    9

    82.0

    0

    81.7

    8

    81.4

    8

    10

    +00.0

    0

    10

    +25.0

    0

    10

    +50.0

    0

    10

    +75.0

    0

    11+

    00.0

    0

    11+

    25.0

    0

    11+

    50.0

    0

    11+

    75.0

    0

    12

    +00.0

    0

    12

    +25.0

    0

    12

    +50.0

    0

    83.8

    2

    81.7

    5N

    78.6

    8

    S78.6

    8

    9+

    80.4

    4

    9+

    97.9

    4

    10

    +94.9

    8

    11+

    93.2

    0

    12

    +28.4

    0

    MATC

    HLIN

    E S

    EE D

    WG C

    2

    203mm SANITARY TRUNK SEWER

    254mm SANITARY TRUNK SEWER

    305mm SANITARY TRUNK SEWER

    BH7

    MAPLE B

    OU

    LE

    VA

    RD

    ALB

    ANI STR

    EET

    DWIGHT AVENUE

    STR

    EET

    MU

    RRIE

    LIMIT O

    F C

    ON

    TR

    AC

    T

    S

    TR

    EET

    BU

    RMIN

    GH

    AM

    FIBRE OPTIC (BELL)

    BELL

    ROGERS

    WATERABANDONED

    ROGERS

    BELL

    150mm WATER

    450mm STORM SEWER

    BELL

    GAS

    ROGERS

    UNKNOWN UTILITY

    400mm WATER

    1350mm STORM SEWER

    450mm STORM SEWER

    400mm WATER

    600 mm STORM SEWER

    BELL

    150mm WATER

    BELL

    TORONTO HYDRO

    ROGERS

    900mm STORM SEWER

    1500mm STORM SEWER

    TORONTO HYDRO

    450mm STORM SEWER

    ROGERS

    GAS

    ROGERS

    50mm GAS

    ABANDONED WATER

    50mm GAS

    400mm WATER

    900mm STORM SEWER

    1500mm STORM SEWER

    BELL

    100mm WATER

    32mm GAS

    BELL

    ROGERS

    1500mm STORM SEWER

    400mm WATER

    600mm STORM SEWER

    ROGERS

    BELL

    GAS

    BELL

    50mm GAS

    ROGERS

    TORONTO HYDRO

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-4 C1

    M.B.

    N

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    252.1mUSING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    LAKE ONTARIO

    179° 180°

    203mm SANITARY SEWER

    203mm SANITARY SEWER

    229mm SANITARY SEWER

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    IIIIII

    I

    III

    I

    I

    IIIIIII

    MH324-028-1 (DETAILS ON SHEET C18)

    MH324-027-1 (DETAILS ON SHEET C18)

    MH324-026-1 (DETAILS ON SHEET C18)

    BH7

    ASPHALT

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    INVERT

    TOP EL. 83.76MH324-028-1

    TOP E

    L. 82.47

    MH324-0

    27-1

    TOP E

    L. 82.09

    MH324-0

    26-1

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONGTOP EL. 83.82

    MH2922504859

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    CLAY SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 203-305mm VITRIFIED

    NOTES:

    FILL

    LEAN CLAY

    WEATHERED SHALE

    JULY 22, 2015

    STR

    EET

    HE

    MA

    N

    TOP E

    L. 81.75

    MH324-0

    25A-1

    MH324-025A-1 (DETAILS ON SHEET C18)

    FROM MH324-028-1 TO MH324-025A-1

    203mm SANITARY SEWER

    203mm SANITARY TRUNK SEWER

    TRUNK SEWER @ 0.53%63.6m- 305mm DIA. V.C. SANITARY

    35.2m- 305mm DIA. V.C. SANITARY TRUNK SEWER @ 0.53%98.2m - 254mm DIA. V.C. SANITARY TRUNK SEWER @ 0.85% 97.0m - 203mm DIA. V.C. SANITARY TRUNK SEWER @ 1.24%

    II

    AC C

    CC

    C

    ISSUED FOR TENDER

    MH2922504859

    -

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • 3

    T

    T T

    T

    T

    T

    T

    T

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    PARKING LOT

    PARKING

    PARKING

    PARKING

    PARKING

    PARKING

    TREED AREA

    TREED AREA

    020680622

    020680621

    E95

    2732-2750

    2724

    2722

    27202718

    2716

    2747

    2731-2735

    2727-2729

    2725

    2723

    27212719

    2711

    2709

    5

    27072705

    2705A2703

    2701

    2708

    271027122714

    2704

    26972693-2697

    2693

    2687

    2688

    12+50

    12+75

    13+00

    13+25

    13+50

    13+75

    14+00

    14+25

    14+50

    14+75

    15+00

    WV#

    WV#

    *

    *

    W78.1

    0

    E78.1

    0

    W77.9

    8

    E77.9

    7

    S78.3

    4

    N78.3

    4

    81.4

    8

    80.9

    8

    80.8

    5

    80.8

    8

    80.9

    6

    81.1

    7

    81.2

    7

    81.3

    5

    81.3

    3

    81.2

    4

    81.1

    4

    81.2

    4

    12

    +50.0

    0

    12

    +75.0

    0

    12

    +92.0

    1

    13

    +00.0

    0

    13

    +25.0

    0

    13

    +50.0

    0

    13

    +75.0

    0

    14

    +00.0

    0

    14

    +25.0

    0

    14

    +50.0

    0

    14

    +64.8

    6

    14

    +75.0

    0

    15

    +00.0

    0

    81.1

    7

    MATC

    HLIN

    E S

    EE D

    WG C

    3

    MATCHLINE

    SEE DWG C1

    AVE

    NU

    ED

    WIG

    HT

    762mm SANITARY TRUNK SEWER

    762mm SANITARY TRUNK SEWER

    N

    J.V. 15ECS-LU-O6TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-5 C2

    M.B.

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    150mm WATER

    525mm STORM SEWER

    150mm GAS

    FIBRE OPTIC (TELUS)

    BELL

    UNKNOWN UTILITY

    UNKNOWN UTILITY

    300mm WATER

    BELL

    ROGERS

    150mm WATER

    2100mm STORM SEWER

    150mm WATER

    300mm WATER

    BELL

    ROGERS

    300mm STORM SEWER

    300mm WATER

    1500mm STORM SEWER

    900mm STORM SEWER

    ROGERS

    BELL

    400mm WATER

    100mm WATER

    900mm STORM SEWER

    BELL

    ROGERS

    FIBRE OPTIC (TELUS)

    150mm GAS

    150mm WATER

    1800mm STORM SEWER

    305mm SANITARY TRUNK SEWER

    250.0m USING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    LAKE ONTARIO

    99°161°

    200mm SANITARY SEWER

    200mm SANITARY SEWER200mm SANITARY SEWER

    200mm SANITARY SEWER

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    CCCCCCCCC I

    A A A A

    A A A A A A

    A

    A

    C

    CC

    CCCC

    CC

    C

    C

    I

    C

    CA

    C

    CA

    SAN MH11

    250mm SANITARY SEWER

    SAN MH

    LAKE SHORE B

    OULEVARD W

    (DETAILS ON SHEET C17)MH324-025-1

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    LANE MARKING (WHITE)

    LANE MARKING (YELLOW)

    LANE MARKING (WHITE)

    TTC TRACK CL (EASTBOUND)

    TTC TRACK CL (WESTBOUND)

    FROM MH324-025-1 TO MH324-024-1

    TOP E

    L. 80.85

    MH324-0

    25-1

    TOP E

    L. 81.17

    MH324-0

    24-1

    INVERT

    MH324-024-1 (DETAILS ON SHEET C17)

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG

    RO

    AD

    SA

    ND B

    EA

    CH

    SANITARY SEWER762mm

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    AND 762mm CLAY TILE SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 305mm VITRIFIED CLAY

    NOTES:

    TRUNK SEWER @ 0.14%141.35m - 762mm DIA. CLAY TILE SANITARY

    172.9m - 762mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.07%63.6m - 305mm DIA. V.C. SANITARY TRUNK SEWER @ 0.53%

    JULY 22, 2015

    I

    I

    A

    C

    C

    C

    C

    ISSUED FOR TENDER

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • HW

    HW

    HW

    HW

    HW

    HW

    HW

    HW

    HW

    2642

    2644

    7

    14

    12

    10

    11

    13

    17

    PARKING

    TREED AREA

    TREED AREA

    020680615

    E115

    2687

    26862682

    26852679

    2677

    2675 2667

    2680 2678

    2676

    2674

    26722670

    2663

    26662660

    6

    26492647

    5

    2

    2656

    2654

    2652

    26502648

    2643

    2645

    8

    6

    4

    15+00

    15+25

    15+50

    15+75

    16+00

    16+25

    16+50

    16+75

    17+00

    17+25 17+50

    *

    *

    HW

    N77.8

    2

    S77.8

    2

    S77.5

    8N

    77.5

    9

    E78.1

    2W

    78.5

    0

    81.2

    4

    81.2

    3

    81.2

    1

    81.3

    1

    81.3

    6

    81.0

    2

    80.7

    8

    80.6

    4

    80.5

    2

    80.5

    0

    80.5

    1

    80.5

    9

    80.6

    9

    15

    +00.0

    0

    15

    +25.0

    0

    15

    +50.0

    0

    15

    +75.0

    0

    16

    +00.0

    0

    16

    +06.2

    1

    16

    +25.0

    0

    16

    +50.0

    0

    16

    +75.0

    0

    17

    +00.0

    0

    17

    +07.6

    2

    17

    +10.5

    0

    17

    +25.0

    0

    17

    +50.0

    0

    81.3

    1

    E78.3

    6

    N77.4

    1S77.5

    6

    MATC

    HLIN

    E S

    EE D

    WG C

    4

    MATC

    HLIN

    E S

    EE D

    WG C

    2

    762mm SANITARY TRUNK SEWER

    RO

    YAL Y

    OR

    K R

    OA

    D

    RO

    YAL Y

    OR

    K R

    OA

    D

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-6 C3

    M.B.

    N

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    150mm WATER

    600mm STORM SEWER

    750mm STORM SEWER

    50mm GAS

    450mm STORM SEWER

    100mm GAS

    ROGERS

    675mm STORM SEWER

    BELL

    ROGERS

    BELL

    150mm WATER

    FIBER OPTIC (TELUS)

    100mm GAS

    100mm GAS

    TORONTO HYDRO

    BELL

    ROGERS

    525mm STORM SEWER

    FIBER OPTIC (TELUS)

    150mm GAS

    150mm WATER

    300mm WATER

    150mm WATER

    ROGERS

    BELL

    300mm WATER

    600mm STORM SEWER

    ROGERS

    BELL

    150mm WATER

    450mm STORM SEWER

    675mm STORM SEWER

    BELL

    ROGERS

    600mm STORM SEWER

    150mm WATER

    300mm WATER

    200mm WATER

    150mm WATER

    (TELUS)FIBRE OPTICS

    100mm GAS

    HYDROTORONTO

    STORM SEWER300mm

    250.0m USING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    LAKE ONTARIO

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    176°

    178°

    171°

    225mm SANITARY SEWER

    375mm SANITARY SEWER

    200mm SANITARY SEWER

    200mm SANITARY SEWER

    200mm SANITARY SEWER

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    C

    C

    A

    I

    CI

    I

    C

    A

    A

    A A

    C

    C

    A

    A

    I

    C

    C

    AI

    CC

    C

    C

    C

    C

    C

    C

    A

    CC

    A

    I

    C

    I

    I

    I

    I

    A

    LAKE SHORE BOULEVARD W

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    762mm SANITARY TRUNK SEWER

    LANE MARKING (WHITE)

    TTC TRACK CL (WESTBOUND)

    LANE MARKING (YELLOW)

    LANE MARKING (WHITE)

    TTC TRACK CL (EASTBOUND)

    FROM MH324-023-1 TO MH324-021-1

    INVERT

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG

    (DETAIL ON SHEET C17)MH324-023-1

    SEWER250mm SANITARY

    STORM SEWER525mm

    TRUNK SEWER915mm SANITARY

    ON SHEET C17)(DETAIL MH324-022-1

    (DETAIL ON SHEET C16)MH324-021-1

    TRUNK SEWER915mm SANITARY

    DWG C20SEE DETAIL

    SANITARY TRUNK SEWER @ 0.02%102.20m - 915mm DIA. CLAY TILE

    SANITARY TRUNK SEWER @ 1.03%2.88m - 915mm DIA. CLAY TILE

    101.4m - 762mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.14% 141.35m - 762mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.11%

    TOP E

    L. 81.31

    MH324-0

    23-1

    TOP E

    L. 80.50

    MH324-0

    22-1

    JULY 22, 2015

    450mm SANITARY SEWER

    229mm SANITARY SEWER

    TOP E

    L. 80.51

    MH324-0

    21-1

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE/PARKING LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 762-915mm CLAY TILE

    NOTES:

    ISSUED FOR TENDER

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • 2636

    2634

    2614

    2616

    2612

    2609

    2613

    2615

    2619

    2627

    2626

    2620

    2618

    2622

    2624

    2630

    2632

    2638

    2640

    2642

    2637

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    TREE

    D

    ARE

    A

    TREE

    D

    ARE

    A

    E116020680614

    020720756

    2643

    2641

    17+50

    17+75

    18+00

    18+25

    18+50

    18+75

    19+00

    19+25 19+50 1

    9+75 2

    0+00

    S77.3

    9

    N77.3

    8

    S77.1

    7

    N77.1

    7

    80.6

    9

    80.7

    2

    80.7

    7

    80.8

    3

    80.8

    9

    81.0

    0

    81.0

    9

    81.2

    3

    81.2

    5

    81.2

    8

    81.3

    8

    81.4

    6

    81.5

    9

    17

    +50.0

    0

    17

    +75.0

    0

    18

    +00.0

    0

    18

    +12.7

    0

    18

    +25.0

    0

    18

    +50.0

    0

    18

    +75.0

    0

    19

    +00.0

    0

    19

    +25.0

    0

    19

    +31.1

    8

    19

    +50.0

    0

    19

    +75.0

    0

    20

    +00.0

    0

    MATC

    HLIN

    E S

    EE D

    WG C

    5

    MATC

    HLIN

    E S

    EE D

    WG C

    3 BH6

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-7 C4

    M.B.

    N

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    150mm WATER

    300mm STORM SEWER

    300mm WATER

    ROGERS

    450mm STORM SEWER

    150mm WATER

    100mm GAS

    TORONTO HYDRO

    TORONTO HYDRO

    ROGERS

    100mm GAS

    150mm WATER

    300mm WATER

    250mm STORM SEWER

    150mm WATER

    250.0m USING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    LAKE ONTARIO

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    165° 165°

    200mm SANITARY SEWER200mm SANITARY SEWER

    A

    I

    I

    A

    II

    I

    I

    A

    I

    I

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    C

    C

    C

    C

    AAI

    C

    AI

    C

    A

    A

    C

    A

    I

    I

    A

    AI

    C

    A

    C

    A

    C

    C

    BOULEVARD WLAKE SHORE

    BH6

    ASPHALTCONCRETEFILL

    FILL

    WEATHERED SHALE

    MH324-020-1 (DETAILS ON SHEET C12)

    SHEET C12)(DETAILS ON MH324-019-1

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    TRUNK SEWER915mm SANITARY

    200mm SANITARY SEWER

    LANE MARKING (WHITE)

    TTC TRACK CL (WESTBOUND)

    LANE MARKING (YELLOW)

    LANE MARKING (WHITE)

    TTC TRACK CL (EASTBOUND)

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG

    INVERT

    FROM MH324-020-1 TO MH324-019-1

    TOP E

    L. 80.83

    MH324-0

    20-1

    TOP E

    L. 81.28

    MH324-0

    19-1

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE

    NOTES:

    115.4m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%118.5m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.18% 102.20m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.02%

    JULY 22, 2015

    ISSUED FOR TENDER

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • 2577

    2581X

    2580

    2582

    2610

    A

    2612

    2610

    2606

    2604

    2608

    2602

    2600

    2597

    2609

    2607

    2603

    2595

    2598

    2596

    2594

    2591

    2585

    2588

    2586

    2584

    2583

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    T

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    TR

    EE

    D

    AR

    EA

    E116

    020810129

    020680613

    020720755

    20+00

    20+25

    20+50

    20+75

    21+00

    21+25

    21+50

    21+75 22+00 22+25 22+50

    *

    #

    S77.0

    6

    N77.0

    5

    S76.9

    0

    N76.8

    9

    81.5

    9

    81.6

    0

    81.6

    0

    81.5

    3

    81.4

    5

    81.2

    8

    81.0

    0

    81.0

    8

    81.1

    3

    81.1

    8

    81.3

    4

    81.4

    7

    20

    +00.0

    0

    20

    +25.0

    0

    20

    +46.6

    3

    20

    +50.0

    0

    20

    +75.0

    0

    21+

    00.0

    0

    21+

    25.0

    0

    21+

    50.0

    0

    21+

    61.0

    8

    21+

    75.0

    0

    22

    +00.0

    0

    22

    +25.0

    0

    22

    +50.0

    0

    81.6

    5

    E77.2

    6W

    77.3

    4

    MATC

    HLIN

    E S

    EE D

    WG C

    6

    MATC

    HLIN

    E S

    EE D

    WG C

    4

    BH4

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    LA

    KE C

    RES

    CE

    NT

    LAKE C

    RESCENT

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-8 C5

    M.B.

    N

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    150mm WATER

    300mm WATER

    150mm WATER

    675mm STORM SEWER

    50mm GAS

    150mm WATER

    250mm STORM SEWER

    300mm WATER

    ROGERS

    150mm WATER

    ROGERS

    300mm WATER

    150mm WATER

    100mm GAS

    TORONTO HYDRO

    TORONTO HYDRO

    FIBRE OPTIC (TELUS)

    675mm STORM SEWER

    50mm GAS

    150mm WATER

    100mm GAS

    TORONTO HYDRO

    TORONTO HYDRO

    BELL

    TORONTO HYDRO

    100mm GAS

    150mm WATER

    ROGERS

    250.0m USING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    LAKE ONTARIO

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    173° 169°

    200mm SANITARY SEWER

    200mm SANITARY SEWER

    200mm SANITARY SEWER

    200mm SANITARY SEWER

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    C

    CC

    C

    AA

    CC

    C

    C

    AC

    CAC

    AC

    A

    C

    C

    C

    C

    A

    A

    CC

    C

    A C

    CA

    C

    C

    C

    C

    A

    C

    C

    LAKE SHORE BOULEVARD W

    200mm SANITARY SEWER

    BH4

    ASPHALT

    FILL

    LEAN CLAY

    WEATHERED SHALE

    MH324-018-1 (DETAILS ON SHEET C12)MH324-017-1 (DETAILS ON SHEET C12)

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    LANE MARKING (WHITE)

    TTC TRACK CL (WESTBOUND)

    LANE MARKING (YELLOW)

    LANE MARKING (WHITE)

    TTC TRACK CL (EASTBOUND)

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG

    FROM MH324-018-1 TO MH324-017-1

    INVERT

    TOP E

    L. 81.65

    MH324-0

    18-1

    TOP E

    L. 81.08

    MH324-0

    17-1

    TRUNK SEWER915mm SANITARY

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE

    NOTES:

    146.10 - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%114.5m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.13% 115.4m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.18%

    JULY 22, 2015

    ISSUED FOR TENDER

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • HW

    2555

    6

    8

    10

    20

    18

    2545

    2543

    25542

    556

    2560

    2558

    42

    2563

    2561

    2562

    11

    9

    5

    2564

    2566

    2570

    2574

    2572

    2571

    2567

    2577

    2575

    2573

    2578

    2576

    2565

    T

    T

    T

    TT

    T

    T

    T

    T

    LS

    LS

    LS

    LS

    LSLS

    LS

    LS

    LS LS

    TR

    EE

    D

    AR

    EA

    TR

    EE

    D

    AR

    EA

    TR

    EE

    D

    AR

    EA

    TR

    EE

    D

    AR

    EA

    020700084020810126020680613

    22+50

    22+75

    23+00

    23+25

    23+50

    23+75

    24+00

    24+25

    24+50

    24+75

    25+00

    WV

    WV#

    WV

    MHBELL

    GV

    S76.7

    5

    N76.7

    5

    S76.7

    3

    N76.7

    2

    S76.6

    6N

    76.6

    6

    S76.6

    0

    N76.6

    0

    S76.5

    8

    N76.5

    8

    81.4

    7

    81.5

    2

    81.4

    4

    81.5

    0

    81.3

    6

    81.2

    5

    81.2

    8

    81.1

    8

    81.2

    3

    81.2

    5

    81.4

    0

    81.6

    5

    81.8

    0

    81.9

    7

    82.0

    3

    82.3

    7

    22

    +50.0

    0

    22

    +75.0

    0

    23

    +00.0

    0

    23

    +07.1

    9

    23

    +25.0

    0

    23

    +41.3

    4

    23

    +50.0

    0

    23

    +75.0

    0

    23

    +97.4

    2

    24

    +00.0

    0

    24

    +25.0

    0

    24

    +50.0

    0

    24

    +62.1

    0

    24

    +75.0

    0

    24

    +79.1

    0

    25

    +00.0

    0

    E77.3

    2W

    77.4

    1

    E78.3

    9W

    77.4

    0

    E77.3

    9

    E77.5

    1

    MATC

    HLIN

    E S

    EE D

    WG C

    7

    MATC

    HLIN

    E S

    EE D

    WG C

    5

    915mm SANITARY TRUNK SEWER

    900mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    SY

    MO

    NS S

    TREET

    MIL

    ES R

    OA

    D

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-9 C6

    M.B.

    N

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    150mm WATER

    TORONTO HYDRO

    1350mm STORM SEWER

    TORONTO HYDRO

    150mm WATER

    300mm WATER

    STORM SEWER (NO FLOW)

    BELL

    ROGERS

    100mm GAS

    375mm STORM SEWER

    UNKNOWN UTILITY

    ROGERS

    150mm WATER

    100mm GAS

    GAS

    300mm WATER

    ROGERS

    32mm GAS

    150mm GAS

    100mm GAS

    TORONTO HYDRO

    150mm WATER

    300mm WATER

    BELL

    ROGERS

    150mm WATER

    BELL

    150mm WATER

    GAS

    300mm WATER

    ROGERS

    150mm WATER

    STORM SEWER (NO FLOW)

    BELL

    32mm GAS

    ROGERS

    100mm GAS

    BELL

    150mm WATER

    TORONTO HYDRO

    1350mm STORM SEWER

    TORONTO HYDRO

    100mm GAS150mm WATER

    300mm WATER

    ROGERS

    250.0m USING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    LAKE ONTARIO

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    179°181°

    181°

    179°178°

    305mm SANITARY SEWER

    300mm SANITARY SEWER

    300mm SANITARY SEWER

    300mm SANITARY SEWER

    200mm SANITARY SEWER

    203mm SANITARY SEWER

    200mm SANITARY SEWER

    300mm STORM SEWER

    200mm SANITARY SEWER

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    A I

    C

    C A

    C

    C A

    C

    C

    A

    CA

    C

    C

    A

    C

    C

    C

    C C

    C

    C

    C

    C

    A

    C

    LAKE SHORE BOULEVARD W

    MH324-016-1 (DETAILS ON SHEET C12)

    MH324-015-1 (DETAILS ON SHEET C12)

    MH324-014-1 (DETAILS ON SHEET C12)

    MH324-015A-1 (DETAILS ON SHEET C15)

    SHEET C14)(DETAILS ON MH324-014A-1

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    LANE MARKING (WHITE)

    TTC TRACK CL (WESTBOUND)

    LANE MARKING (YELLOW)

    (EASTBOUND)TTC TRACK CL

    (WHITE)LANE MARKING

    INVERT

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG

    FROM MH324-016-1 TO MH324-014A-1

    TOP E

    L. 81.50

    MH324-0

    16-1

    TOP E

    L.81.25

    MH324-0

    15-1

    TOP E

    L. 81.80

    MH324-0

    14-1

    TRUNK SEWER @ 0.10% CLAY TILE SANITARY 70.3m - 915mm DIA.

    TRUNK SEWER @ 0.10% CLAY TILE SANITARY 17.0m - 915mm DIA.

    64.7m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10% 56.1m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10% TRUNK SEWER @ 0.09%34.2m - 915mm DIA. CLAY TILE SANITARY

    146.10m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%

    120.8m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER TRUNK SEWER 87.3m- 915mm DIA. CLAY TILE SANITARY

    JULY 22, 2015

    356mm SANITARY SEWER

    254mm SANITARY SEWER

    UNKNOWN SANITARY SEWER

    SEWER203mm SANITARY

    SEE NOTE 4

    (SEE N

    OTE 5)

    TOP E

    L. 81.23

    MH324-0

    15A-1

    (SEE N

    OTE 5)

    TOP E

    L. 82.03

    MH324-0

    14A-1

    5. NO FULL ACCESS TO TRUNK FROM MH324-15A-1 AND MH324-14A-1

    MAINTAIN TIME OR SPACE SEPERATION. BE REPLACED IN 2015-2016. COORDINATE CONSTRUCTION TO4. EXISTING WATERMAIN ON SYMONS STREET IS PRPOSED TO

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE

    NOTES:

    TORONTO HYDRO

    ISSUED FOR TENDER

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • HW

    HW

    HW

    HW

    2517

    42

    20

    2519

    2521

    2515

    2524 2

    522

    2518

    2516

    25202532

    2536

    2500

    2502

    2510

    25122

    514

    2506

    2508

    2504

    2501

    2513

    2507

    2499

    2546

    T

    T

    TT

    T

    T

    T

    T

    T

    TT

    T

    T

    T

    LS

    LS LS

    LS

    LS

    LS

    LS

    LSLS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    FP

    LS PARKING

    PARKING

    TR

    EE

    D

    AR

    EA

    TR

    EE

    D

    AR

    EA

    TR

    EE

    D

    AR

    EA

    E118

    020680612

    020810120

    25+00

    25+25

    25+50

    25+75

    26+00

    26+25

    26+50

    26+75

    27+00

    27+25

    27+50

    WV

    WV

    WV

    # *#

    HW

    HW

    HW

    HW

    HW

    S76.5

    1

    N76.5

    1

    S76.4

    6

    N76.4

    6

    S76.4

    4

    N76.4

    4

    S76.4

    1

    N76.3

    9

    S76.3

    9

    N76.3

    9

    S76.3

    2

    N76.3

    2

    82.3

    7

    82.5

    7

    82.7

    3

    82.6

    3

    82.5

    1

    82.5

    0

    82.3

    3

    82.2

    9

    81.9

    2

    81.7

    5

    81.4

    581.4

    3

    80.9

    0

    80.4

    7

    80.3

    1

    80.1

    5

    25

    +00.0

    0

    25

    +25.0

    0

    25

    +49.4

    225

    +50.0

    0

    25

    +75.0

    0

    25

    +88.7

    2

    26

    +00.0

    0

    26

    +03.4

    2

    26

    +19.3

    9

    26

    +25.0

    0

    26

    +50.0

    0

    26

    +59.7

    8

    26

    +73.8

    326

    +75.0

    0

    27

    +00.0

    0

    27

    +25.0

    0

    27

    +36.5

    9

    27

    +50.0

    0

    S76.4

    7

    N76.4

    7

    82.7

    3

    E77.0

    0

    E78.9

    8

    82.3

    3

    E76.9

    0W

    77.0

    5

    E78.8

    5

    W78.7

    0

    E78.5

    0

    E76.8

    7W

    77.6

    0

    MATC

    HLIN

    E S

    EE D

    WG C

    8

    MATC

    HLIN

    E S

    EE D

    WG C

    6

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    BH3

    QUEE

    NS AV

    ENUE

    DO

    UG

    LAS B

    OU

    LE

    VA

    RD

    NO

    RRIS C

    RES

    CE

    NT

    HIL

    LSID

    E A

    VE

    NU

    E

    TRUNK SEWER915mm SANITARY

    RO

    AD

    SU

    MM

    ER

    HIL

    L

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-10 C7

    M.B.

    N

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    ROGERS

    TORONTO HYDRO

    50mm GAS

    200mm WATER

    BELL

    BELL

    150mm WATER

    TORONTO HYDRO

    ROGERS

    WATER

    ROGERS

    TORONTO HYDRO

    150mm WATER

    TORONTO HYDRO

    50mm GAS

    BELL

    ROGERSABANDONED WATER

    3600 x 2400mm STORM SEWER

    WATER

    100mm GAS

    GAS

    BELL

    ROGERS

    150mm WATER

    BELL

    GAS

    300mm WATER

    ROGERS

    300mm STORM SEWER

    150mm WATER

    150mm GAS

    100mm GAS

    WATER

    3600 x 2400mm STORM SEWER

    150mm WATER

    150mm GAS

    ROGERS

    150mm WATER

    TORONTO HYDRO

    250mm STORM SEWER

    150mm GAS

    BELL

    TORONTO HYDRO

    250mm STORM SEWER

    300mm WATER

    150mm WATER

    150mm GAS

    50mm GAS

    ROGERS

    WATERABANDONED

    LAKE ONTARIO

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    180° 179°

    176°

    177°182° 179° 181°

    200mm SANITARY SEWER

    200mm SANITARY SEWER

    ABANDONED SANITARY SEWER

    250mm SANITARY SEWER

    300mm SANITARY SEWER

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    A

    C

    A

    A

    C

    C

    C

    C

    A

    C

    C

    A

    C C

    C C

    A

    C C

    AC

    C

    C

    C

    A

    C IC

    A

    LAKE SHORE BOULEVARD W

    BH3

    250mm SANITARY SEWER

    ASPHALTFILL

    LEAN CLAY

    SEWERSANITARY250mm

    SEWERSANITARY250mm

    250mm SANITARY SEWER

    SEWERSANITARY 250mm

    SEWERSANITARY357mm

    MH324-013-1 (DETAILS ON SHEET C12)

    SHEET C13)(DETAILS ONMH324-010-1

    MH324-011-1 (DETAILS ON SHEET C14)

    MH324-012-1 (DETAILS ON SHEET C13)

    (DETAILS ON SHEET C13)MH324-008-1

    MH324-009-1 (DETAILS ON SHEET C13)

    SHEET C12)(DETAILS ON MH324-007-1

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    SEWERSANITARY250mm

    LANE MARKING (WHITE)

    TTC TRACK CL (EASTBOUND)

    LANE MARKING (YELLOW)

    TTC TRACK CL (WESTBOUND)

    LANE MARKING (WHITE)

    FROM MH324-013-1 TO MH324-007-1

    INVERT

    150mm GAS

    TOP E

    L. 82.73

    MH324-0

    13-1

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG

    TOP E

    L. 80.31

    MH324-0

    07-1

    ALL SERVICE CONNECTIONSINSTALL TOP HATS ON

    236.6m USING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    87.3m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER 187.3m- 915mm DIA. CLAY TILE SANITARY TRUNK SEWER

    JULY 22, 2015

    LINER @ 0.11%WITH EXISTING CIPPSANITARY TRUNK SEWER 95.3m - 915mm DIA. CLAY TILE

    62.8m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%

    SANITARY TRUNK SEWER @ 0.10%14.0m - 915mm DIA. CLAY TILE

    TRUNK SEWER @ 0.11%40.4m - 915mm DIA. CLAY TILE SANITARY

    SANITARY TRUNK SEWER @ 0.11%16.0m - 915mm DIA. CLAY TILE

    SANITARY TRUNK SEWER @ 0.09%14.7m - 915mm DIA. CLAY TILE

    TRUNK SEWER @ 0.09%39.30 - 915mm DIA. CLAY TILE SANITARY

    70.3m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.09%

    SHALEWEATHERED

    TRUNK SEWER915mm SANITARY

    (SEE N

    OTE 4)

    TOP E

    L. 82.51

    MH324-0

    12-1

    (SEE N

    OTE 4)

    TOP E

    L. 82.33

    MH324-0

    11-1

    (SEE N

    OTE 4)

    TOP E

    L. 82.33

    MH324-0

    10-1

    (SEE N

    OTE 4)

    TOP E

    L. 81.75

    MH324-0

    09-1

    (SEE N

    OTE 4)

    TOP E

    L. 81.45

    MH324-0

    08-1

    4. NO FULL ACCESS TO TRUNK FROM MH324-012-1 TO MH324-008-1

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE

    NOTES:

    ISSUED FOR TENDER

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • HW

    HW

    HW

    1

    2441

    2435-2437

    2435

    2415

    2413

    4A

    2432

    1

    2428

    2424-2426

    2420-2422

    2434-2436

    2430

    2430-2432

    2438

    2448

    2444-2446

    2442

    6

    4

    6A

    1

    2492249424

    962498

    2500

    2499

    2497

    2491

    2485-2489

    2483

    2472

    2480

    2454

    2458

    2456

    2449-2481

    2457

    2455

    2445

    2427

    2423-2425

    2409-2411

    2407

    2405

    2413

    R

    T

    T

    T

    T

    T

    T

    T

    T

    LS

    LS LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS LS

    LS

    LS LS

    PARKING

    PARKING

    PARKING

    PARKING

    PARKING

    PARKING

    TR

    EE

    D

    AR

    EA

    PA

    RKIN

    G

    PA

    RKIN

    G

    02068610R

    020700085

    020680610

    27+50 27+75 28+00 28+25

    28+50

    28+75

    29+00

    29+25

    29+50

    29+75

    30+00

    *

    HW

    S76.2

    2

    N76.2

    1

    S74.5

    0

    N74.5

    0

    S74.2

    2

    N74.2

    1

    80.1

    5

    79.8

    9

    79.7

    2

    79.5

    2

    79.4

    6

    79.1

    9

    78.7

    0

    78.2

    0

    77.4

    0

    77.3

    1

    77.2

    9

    77.3

    5

    27

    +50.0

    0

    27

    +75.0

    0

    28

    +00.0

    0

    28

    +25.0

    0

    28

    +31.8

    8

    28

    +50.0

    0

    28

    +75.0

    0

    29

    +00.0

    0

    29

    +25.0

    0

    29

    +35.9

    7

    29

    +50.0

    0

    29

    +62.4

    3

    29

    +75.0

    0

    30

    +00.0

    0

    77.5

    9

    77.7

    6

    W75.6

    5

    W74.7

    5

    MATC

    HLIN

    E S

    EE D

    WG C

    7

    MATC

    HLIN

    E S

    EE D

    WG C

    9

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    915mm SANITARY TRUNK SEWER

    ALLEN A

    VEN

    UE

    MIMIC

    O A

    VENUE

    PRIM

    ROSE A

    VE

    NU

    E

    J.V. 15ECS-LU-06TT

    1 07-22-2015

    PLAN AND PROFILE

    1058-2013-19-11 C8

    M.B.

    N

    ARE IN METERS UNLESS OTHERWISE NOTED

    MEASUREMENTS SHOWN ON THESE PLANS

    METRIC

    TORONTO HYDRO

    ABANDONED GAS

    150mm WATER

    150mm GAS

    250mm STORM SEWER

    32mm GAS

    BELL

    UNKNOWN UTILITY

    300mm STORM SEWER

    150mm WATER

    ABANDONED GAS

    150mm WATER

    TORONTO HYDRO

    150mm GAS

    300mm STORM SEWER

    ROGERS

    300mm WATER

    600mm STORM SEWER50mm GAS

    ROGERS

    ABANDONED GAS

    150mm WATER

    TORONTO HYDRO

    750mm STORM SEWER

    FIBRE OPTIC (ROGERS)

    BELL

    150mm GAS

    375mm STORM SEWER

    150mm WATER

    300mm WATER

    150mm WATER

    300mm STORM SEWER

    32mm GAS

    BELL

    ROGERS

    TORONTO HYDRO

    150mm WATER

    BELL

    ROGERS

    300mm STORM SEWER

    150mm WATER

    BELL

    ROGERS

    TORONTO HYDRO

    50mm GAS

    250mm STORM SEWER

    300mm WATER

    ROGERS

    LAKE ONTARIO

    LAKE SHORE SANITARY TRUNK SEWER

    REHABILITATION

    194° 181°

    180°

    225mm SANITARY SEWER

    300mm SANITARY SEWER

    300mm SANITARY SEWER

    250mm SANITARY SEWER

    250mm SANITARY SEWER200mm SANITARY SEWER

    200mm SANITARY SEWER

    LEGEND:

    ACTIVE CONNECTION

    INCONCLUSIVE CONNECTION

    CAPPED CONNECTION

    A

    I

    C

    A

    A AA

    A

    A

    A

    A

    A

    A

    A

    A

    A

    A

    C

    C

    CAAI

    C

    IC

    C

    C

    A

    C

    A

    CC

    I

    C A

    C

    A

    C

    C

    C A

    C

    C

    C C

    C

    30+00

    LAKE SHORE BOULEVARD W

    254mm SANITARY SEWER

    MH324-004-1 (DETAILS ON SHEET C12)

    MH324-005-1 (DETAILS ON SHEET C12)

    MH324-006-1 (DETAILS ON SHEET C12)

    JOHN KELLY, P. ENG.

    DIRECTOR,

    LINEAR UNDERGROUND INFRASTRUCTURE

    DIRECTOR,

    GRAHAM HARDING, P.ENG.

    WATER INFRASTRUCTURE MANAGEMENT

    DIRECTOR,

    OPERATIONAL SUPPORT

    RICHARD NOEHAMMER, P.ENG.

    SIGNEDINITIALREVISIONSDATENo.

    ENGINEERING AND CONSTRUCTION SERVICES

    DESIGN:

    DATE:

    SCALE:

    DRAFTING: CHECK:

    DRAWING

    NUMBER:

    CHECKED CONTRACT No.

    Water

    HOR 1:500, VERT 1:100

    EXISTING

    GROUND

    ELEVATION

    ELEVATION

    CHAINAGE

    65m

    DATUM ELEV.

    70m

    75m

    80m

    85m

    LANE MARKING (WHITE)

    TTC TRACK (EASTBOUND)

    LANE MARKING (YELLOW)

    TTC TRACK (WESTBOUND)

    LANE MARKING (WHITE)

    INVERT

    FROM MH324-006-1 TO MH324-004-1

    SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG

    TOP E

    L. 79.46

    MH324-0

    06-1

    TOP E

    L. 77.59

    MH324-0

    05-1

    TOP E

    L. 77.31

    MH324-0

    04-1

    168.1m USING CIPP LINER

    WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER

    INSTALL TOP HATS ON ALL SERVICE CONNECTIONS

    MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN

    TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED

    SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE

    NOTES:

    TRUNK SEWER @ 0.15%109.3m - 915mm DIA. CLAY TILE SANITARY

    TRUNK SEWER @ 1.06%26.5m - 915mm DIA. CLAY TILE SANITARY

    104.1m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 1.64% WITH EXISTING CIPP LINER @ 0.11%95.3m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER

    JULY 22, 2015

    ISSUED FOR TENDER

    KEY PLAN(NOT TO SCALE)

    AV

    EN

    UE

    DWIG

    HT

    ALBA

    NI STR

    EET

    MURRIE

    STRE

    ET

    STRE

    ETBURMING

    HAM

    BOUL

    EVAR

    DMA

    PLE

    MILES RO

    AD

    STREETS

    YMONS

    QU

    EE

    NS

    AV

    E

    AVENUEALLEN

    MIMICO AV

    ENUE

    AVENUEPR

    IMROSE

    AVENUE

    SUPERIOR

    AVENUE

    SUPERIOR

    SYMO

    NS S

    TREET

    LAKE

    CRES

    ELMA

    STRE

    ET

    STRU

    THER

    S ST

    REET

    LAKE

    CRES

    STRU

    THER

    S ST

    REET

    EAS

    TB

    OU

    RN

    E

    CR

    ES

    DA

    RT

    MO

    UT

    H

    CR

    AV

    EN

    UE

    DWIG

    HT

    AV

    EN

    UE

    DWIG

    HT

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    RE

    ET

    FO

    UR

    TH S

    TR

    EE

    T

    FIF

    TH S

    TR

    EE

    T

    SIX

    TH S

    TR

    EE

    T

    SE

    CO

    ND

    ST

    THIR

    D

    ST

    BLVDS

    HOREL

    AKE

    BLVDS

    HOREL

    AKE

    STRE

    ETBURMING

    HAM

    STREETS

    YMONS

    AVENUEM

    IMICO

    AVENUEH

    ILLSID

    E

    AVENUEH

    ILLSID

    E

    STANLE

    YAVENU

    E

    CAVELL AV

    ENUE

    NORRIS CRES

    DOUGLAS BLVD

    SUMMERHILL RD

    QU

    EE

    NS

    AV

    E

    WH

    EA

    TFIE

    LD

    RD

    CE

    NT

    RA

    L S

    TR

    EE

    T

    GE

    OR

    GE S

    TR

    EE

    T

    RO

    YA

    L

    YO

    RK

    RO

    AD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    GE

    OR

    GE S

    TR

    EE

    T

    ELIZ

    AB

    ET

    H S

    TR

    EE

    T

    ST

    ATIO

    N

    RD

    ST

    ATIO

    N

    RD

    FIR

    ST

    ST

    SA

    ND

    BE

    AC

    H

    RD

    RO

    YA

    L

    YO

    RK

    RO

    AD

    BLVD

    ISLAND VIEW

    CRESL

    AKE

    EDYTH COURT

    RO

    AD

    WH

    EA

    TFIE

    LD

    N

    BLVD W.

    LAKE

    SHOR

    E

    BO

    ULE

    VA

    RD

    W.

    LA

    KE S

    HO

    RE

    HEMAN S

    TREET

  • 2389-2391

    9

    11

    2404-2406

    2408

    2412

    2410

    241624

    18

    2428

    2424-2426

    2420-2422

    2403

    2405

    2401 2399

    2389

    A-2391A

    2389

    B-2391B

    2392-2398

    2388

    A-2390

    A

    2383-2387

    2386

    A

    2388

    B-2390

    B

    2388-2390

    2386

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    LS

    PA

    RKIN

    G

    PA

    RKIN

    G

    PA

    RKIN

    G

    PA

    RKIN

    G

    PA

    RKIN

    G

    PA

    RKIN

    G

    PA

    RKIN

    G

    PA

    RKIN

    G

    PARKING

    E120

    30+0