Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
N
LA
KE S
HO
RE B
LV
D W
FOURTH ST
THIRD ST
SECON
D ST
FIRST
STLAKE SHORE DR
SAND B
EACH R
D
DWIGH
T AVE
ALB
ANI S
T
ROYAL YO
RK RD
EASTBOURNE CRES
DARTMOUTH CRES
SUSSEX D
R
LA
KE C
RES
LAKE C
RES
WHEAT
FIELD
RD
SY
MO
NS S
T
QUEEN
S AVE
HIL
LSID
E A
VE
NO
RRIS C
RES
DO
UG
LAS B
LV
DMILES R
D
SU
MM
ER
HIL
L R
D
ALLE
N A
VE
MIMIC
O A
VE
PRIM
ROSE A
VE
SUPE
RIO
R A
VE
SUPERIO
R A
VE
ALB
ERT A
VE
STANLEY AVE
STANLEY AVE
BU
RLIN
GTO
N S
T
LAKE SHORE BLVD W
VICTORIA ST
LO
UIS
A S
T
ALE
XA
NDER S
T
BLV
DM
APLE
ENGINEERING AND CONSTRUCTION SERVICES
LOCATION PLAN
G1DRAWING
NUMBER:
Water
GENERAL MANAGER
TORONTO WATER
LOU DI GIRONIMO
ENGINEERING AND CONSTRUCTION SERVICES
MICHAEL D'ANDREA, P. ENG.
EXECUTIVE DIRECTOR
15ECS-LU-06TT
1058-2013-19-1
1:5000
LAKE SHORE SANITARY TRUNK SEWER AND MAINTENANCE HOLES REHABILITATION
LAKE SHORE BLVD W
MIMICO P.S.
MU
RRIE S
T
LA
KE C
RES
HE
MA
N S
T
BIR
MIN
GH
AM S
T
LAKE ONTARIO
LAKE ONTARIO
JULY 22, 2015
BETWEEN MH324-028-1 AND MH324-001-1
ISSUED FOR TENDER
DRAWING DESCRIPTIONCITY DWG No.
2
3
4
1
5
6
7
8
9
10
11
12
27
28
29
13
15
14
30
17
18
21
24
20
26
32
31
33
34
25
16
DRAWING INDEX
DISCIPLINE
TITLE PAGE1058-2013-19-1 G1
ITEM No.
1058-2013-19-2 G2 DRAWING INDEX AND KEY MAP
1058-2013-19-3 G3
1058-2013-19-4 C1
1058-2013-19-5 C2
C3
C4
C5
C6
C7
C8
C9
1058-2013-19-6
1058-2013-19-7
1058-2013-19-8
1058-2013-19-9
1058-2013-19-10
1058-2013-19-11
1058-2013-19-12
J.V. 15ECS-LU-06TT
1 07-22-2015
1058-2013-19-2 G2
M.B.
N
LA
KE S
HO
RE B
LV
D W
FOURTH ST
THIRD ST
SECON
D ST
FIRST
ST
LAKE SHORE DR
SAND B
EACH R
D
DWIGH
T AVE
ALB
ANI S
T
ROYAL YO
RK RD
EASTBOURNE CRES
DARTMOUTH CRESSUSSEX D
R
LA
KE C
RES
LAKE C
RES
WHEAT
FIELD
RD
SY
MO
NS S
T
QUEEN
S AVE
HIL
LSID
E A
VE
NO
RRIS C
RES
DO
UG
LAS B
LV
DMILES R
D
SU
MM
ER
HIL
L R
D
ALLE
N A
VE
MIMIC
O A
VE
PRIM
ROSE A
VE
SUPE
RIO
R A
VE
SUPERIO
R A
VE
ALB
ERT A
VE
STANLEY AVE
STANLEY AVE
BU
RLIN
GTO
N S
T
LAKE SHORE BLVD W
VICTORIA ST
LO
UIS
A S
T
ALE
XA
NDER S
T
1058-2
013-19-4-C
1
1058-2013-19-7-C4
1058-2013-19-8-C5 1058-2013-19-9-C6 1058-2013-19-10-C71058-2013-19-11-C8
1058-2013-19-27
1058-2013-19-28
1058-2013-19-29
1058-2013-19-30
C24
C25
C26
C27
TRAFFIC MANAGEMENT PLAN (1)
TRAFFIC MANAGEMENT PLAN (2)
TRAFFIC MANAGEMENT PLAN (3)
TRAFFIC MANAGEMENT PLAN (4)
1058-2
013-1
9-5-C
2
1058-2013-19-12-C9
BLV
DM
APLE
1058-2013-19-6-C3
KEY MAP1:5000
LAKESHORE SANITARY TRUNK SEWER
REHABILITATION
1058-2013-19-13 C10
1058-2013-19-14 C11
1058-2013-19-15 C12
1058-2013-19-16 C13
1058-2013-19-17 C14
1058-2013-19-18 C15
1058-2013-19-19 C16
1058-2013-19-20 C17
1058-2013-19-21 C18
1058-2013-19-24 C21
1058-2013-19-25 C22
1058-2013-19-26 C23
1058-2013-19-31 C28
1058-2013-19-32 C29
1058-2013-19-33 C30
1058-2013-19-34 C31
19
C19
C2023
22 1058-2013-19-22
1058-2013-19-23
MAINTENANCE HOLE SCHEDULE (1)
MAINTENANCE HOLE SCHEDULE (2)
MAINTENANCE HOLE SCHEDULE (3)
HE
MA
N S
T
MU
RRIE S
T
LA
KE C
RES
BIR
MIN
GH
AM S
T
LAKE ONTARIO
LAKE ONTARIO
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
AS SHOWN
1058-2
013-19-27-C2
4
1058-2013-19-28-C25
1058-2013-19-29-C261058-2013-19-30-C27
1058-2
013-19-34-C3
1
1058-2013-19-35-C32
INDEX AND KEY MAP
PLAN
GENERAL NOTES, ABBREVIATIONS AND LEGEND
35
37
1058-2013-19-35 C32
1058-2013-19-37 C34
1058-2013-19-36-C331058-2013-19-37-C34
TRAFFIC MANAGEMENT PLAN (5)
1058-2
013-1
9-3
1-C
28
JULY 22, 2015
36 1058-2013-19-36 C33
MISCELLANEOUS DETAILS
MAINTENANCE HOLE REPAIR DETAILS (2) - TYPE 3
MAINTENANCE HOLE REPAIR DETAILS (3) - TYPE 4
MAINTENANCE HOLE REPAIR DETAILS (4) - TYPE 5
MAINTENANCE HOLE REPAIR DETAILS (6) - TYPE 8
MAINTENANCE HOLE REPAIR DETAILS (7) - TYPE 9
MAINTENANCE HOLE REPAIR DETAILS (10)
MAINTENANCE HOLE REPAIR DETAILS (11)
BYPASS PUMPING STAGING, PHASE 1
BYPASS PUMPING STAGING, PHASE 1 & 2
BYPASS PUMPING STAGING, PHASE 3
MAINTENANCE HOLE REPAIR DETAILS (1) - TYPES 1 AND 2
MAINTENANCE HOLE REPAIR DETAILS (5) - TYPES 6 AND 7
MAINTENANCE HOLE REPAIR DETAILS (8) - TYPES 10 AND 11
MAINTENANCE HOLE REPAIR DETAILS (9) - TYPES 12 AND 13
BYPASS PIPING AND PAVEMENT RESTORATION DETAILS
MH324-028-1 to MH324-025A-1 - PLAN AND PROFILE
MH324-025-1 to MH324-024-1 - PLAN AND PROFILE
MH324-023-1 to MH324-021-1 - PLAN AND PROFILE
MH324-020-1 to MH324-019-1 - PLAN AND PROFILE
MH324-018-1 to MH324-017-1 - PLAN AND PROFILE
MH324-016-1 to MH324-014A-1 - PLAN AND PROFILE
MH324-013-1 to MH324-007-1 - PLAN AND PROFILE
MH324-006-1 to MH324-004-1 - PLAN AND PROFILE
MH324-003-1 to MH324-001-1 - PLAN AND PROFILE
BYPASS PUMPING STAGING, PHASE 4
TRAFFIC MANAGEMENT PLAN (6)
TRAFFIC MANAGEMENT PLAN (7)
38
39
1058-2013-19-38
1058-2013-19-39
C35
C36
ISSUED FOR TENDER
M.D. 15ECS-LU-06TT
1 07-22-2015
1058-2013-19-3 G3
M.B.
LAKESHORE SANITARY TRUNK SEWER
REHABILITATION
GENERAL NOTES
LEGISLATION, REGULATION AND CODES
CONSTRUCTION NOTES
ADVERSELY AFFECT ADJACENT LANDS.ALL AREA GRADING AND RESULTING DRAINAGE PATTERNS SHALL NOT5.
THE CONTRACTOR'S EXPENSE.ACCURACY AS THE ORIGINAL MONUMENT(S) IN A TIMELY MANNER, AND ATOF THE WORKS. PERFORM THE WORKS TO PRODUCE THE SAME LEVEL OFPOINTS, AND STAKES WHICH ARE DISTURBED OR DESTROYED AS A RESULTMAINTAIN, RELOCATE, OR REPLACE EXISTING SURVEY MONUMENT, CONTROL8.
UTILITY SEPARATIONS PRESCRIBED BY UTILITY OWNERS ARE TO BE ADHERED TO.PROTECT ALL EXISTING UTILITIES. HAND EXCAVATION REQUIREMENTS AND9.
STANDARDS.ACCORDANCE WITH ALL APPLICABLE AND CURRENT CITY OF TORONTORESTORATION TO THE SITE MUST BE CONSTRUCTED AND CARRIED OUT INAND TO THE SATISFACTION OF THE CONTRACT ADMINISTRATOR. ALLRESTORE ALL DISTURBED AREAS TO THE ORIGINAL CONDITION OR BETTER6.
CONTACT INFORMATION
ORIGINAL DATA SOURCE
ENVIRONMENTAL NOTES
VERTICAL DATUM 1929 (NGVD 29). NORTH AMERICAN DATUM 1927 (NAD 27), AND VERTICAL DATUM: NATIONAL GEODETIC
HORIZONTAL DATUM: 3-DEGREE MODIFIED TRANSVERSE MERCATOR (MTM), ONTARIO ZONE 10,1.
NECESSARY CHANGES.AND THE CONTRACT ADMINISTRATOR SHALL NOTIFY THE CITY OF THE AND THE LAYOUT SHALL BE REPORTED TO THE CONTRACT ADMINISTRATOR PRIOR TO CONSTRUCTION. ANY DISCREPANCIES BETWEEN THE DRAWINGS ALL SURVEY POINTS SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR 3.
CONFIRMING CLEARANCE FOR CONSTRUCTION.UTILITIES AND PIPE LINES, STRUCTURES AND FACILITIES AS REQUIRED,CONFIRM EXISTING DIMENSIONS, ELEVATIONS AND LOCATION OF ALL BASED UPON RECORD DRAWINGS AND INFORMATION. CONTRACTOR TO EXISTING UTILITIES AND PIPE LINES SHOWN IN APPROXIMATE LOCATION 4.
STRUCTURES, OR TOP OF SIDEWALK UNLESS OTHERWISE NOTED.ELEVATIONS GIVEN ARE FINISHED GRADE, TOP OF PAVEMENT, TOP OF 5.
REGION CONSERVATION AUTHORITY.BY THE CONTRACT ADMINISTRATOR AND THE TORONTO AND APPROVED
NATIVE/NON-INVASIVE SPECIES UPON COMPLETION OF THE WORK ASWITHALL DISTURBED VEGETATED AREAS SHALL BE STABILIZED AND RESTORED7.
AND ELEVATIONS AND REPORT ANY DISCREPANCIES TO THE CONTRACT ADMINISTRATOR.CONTRACTOR TO FIELD VERIFY SEWER AND ALL MAINTENANCE HOLE DIMENSIONS 16.
AND ADJUST WORK PLAN ACCORDINGLY PRIOR TO BEGINNING CONSTRUCTION.THOSE SHOWN. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PROVIDED BY FIELD SURVEY DATED 2013. EXISTING CONDITIONS MAY VARY FROM SOURCE OF TOPOGRAPHY SHOWN ON THE DRAWINGS ARE BASE MAPS 6.
AND WATERMAINS MANUAL.6, MATERIAL SPECIFICATIONS FROM DESIGN CRITERIA FOR SEWERSMATERIAL/MANUFACTURER SPECIFICATIONS AS REQUIRED BY CHAPTERAPPURTENANCES, SHALL BE ACCORDING TO CITY OF TORONTOALL MATERIAL FOR SEWER, FORCEMAIN, WATERMAIN, HYDRANTS AND13.
OF THE CONTRACT ADMINISTRATOR.OF CONSTRUCTION AND APPROPRIATE ACTION TAKEN TO THE SATISFACTIONDRAWINGS MUST BE REPORTED TO THE CITY PRIOR TO COMMENCEMENTANY DISCREPANCIES BETWEEN SITE CONDITIONS AND CONSTRUCTION15.
EXPRESSED IN MILLIMETRES (mm) UNLESS OTHERWISE NOTED.ALL DIMENSIONS ARE EXPRESSED IN METRES (m) AND PIPE SIZES ARE 18.
ALL ELEVATIONS ARE IN METRES (m) UNLESS NOTED OTHERWISE.19.
ADMINISTRATOR AND THE CITY.GENERATORS SHALL BE MUFFLED TO THE SATISFACTION OF THE CONTRACT BYPASS PUMPING SHALL RUN ON A CONTINUNOUS BASIS WHEN REQUIRED, 7.
DAYS PRIOR TO THE COMMENCEMENT OF ANY WORK.ADMINISTRATOR AND CITY STAFF IS TO BE HELD A MINIMUM OF FIVE WORKINGWORK. A PRE-CONSTRUCTION COORDINATION MEETING WITH CONTRACTNOTICE TO SPECIFY THE ANTICIPATED DATE OF COMMENCEMENT OF THEPROVISIONS HEREOF AND GIVING 10 WORKING DAYS PRIOR WRITTENPORTION OF THE INFRASTRUCTURE WORK IN ACCORDANCE WITH THE SCHEDULE, APPROVED TRAFFIC STAGING PLANS AND PERMITS FOR SUCHOBTAINED APPROVED CONSTRUCTION DRAWINGS, APPROVED PROJECTNO PORTION OF THE WORK SHALL BE CARRIED OUT WITHOUT FIRST HAVING1.
AND DEPTH OF ANY UTILITY AND SHALL BE LIABLE FOR ALL OR ANY DAMAGE.THE CONTRACTOR SHALL SATISFY THEMSELVES AS TO THE ACTUAL LOCATION REFERENCE PURPOSES ONLY AND IN GENERAL ARE SHOWN AT NOMINAL DEPTHS. ALL EXISTING UTILITIES SHOWN ON DRAWINGS (PLAN AND PROFILE) ARE FOR 14.
LEAVING THE SITE "UNTREATED."PILING OPERATIONS AND SHALL BE LOCATED TO PREVENT SURFACE RUNOFF FROM DRAWINGS ARE TO BE IN PLACE PRIOR TO INITIATION OF EXCAVATION AND STOCK SEDIMENTATION AND EROSION CONTROLS IN ACCORDANCE WITH THE CONTRACT 2.
CONTRACTOR (AND AFTER ANY STORM EVENT) AND CLEARED OR REPLACED, AS REQUIRED.ALL SEDIMENTATION AND EROSION CONTROLS ARE TO BE INSPECTED REGULARLY BY THE 3.
OF THE CONTRACT ADMINISTRATOR.BE REMOVED FOLLOWING CONSTRUCTION AND AREAS RESTORED TO THE SATISFACTION ALL EROSION CONTROL AND TEMPORARY ACCESSES, STRUCTURES AND FACILITIES TO 8.
REMOVE SILT FROM DEWATERING AND OTHER PUMPING OPERATIONS PRIOR TO DISCHARGE.9.
GEOTECHNICAL AND HYDROLOGICAL REPORTS
SPECIFICATION IS AVAILABLE.CITY OF TORONTO, BE USED WHERE NO CITY STANDARD ORAND SPECIFICATIONS MAY, SUBJECT TO THE APPROVAL OF THEAND SPECIFICATIONS. ONTARIO PROVINCIAL STANDARD DRAWINGSACCORDING TO THE LATEST CITY OF TORONTO STANDARD DRAWINGSALL WORK WITHIN THE CITY RIGHT-OF-WAY SHALL BE CONSTRUCTED1.
DEEMED TO BE THE CONSTRUCTOR AS DEFINED IN THE ACT.CONSTRUCTION PROJECTS. THE GENERAL CONTRACTOR SHALL BEOCCUPATIONAL HEALTH AND SAFETY ACT AND REGULATIONS FORALL WORK SHALL BE COMPLETED ACCORDING TO THE CURRENT2.
BOOK 7: TEMPORARY CONDITIONS FIELD EDITION.SHALL BE ACCORDING TO THE CURRENT ONTARIO TRAFFIC MANUALALL TEMPORARY TRAFFIC CONTROL AND SIGNAGE DURING CONSTRUCTION3.
UTILITY CUTS. CONSENT REQUIREMENTS, APPENDIX D, TEMPORARY REPAIRS TOTEMPORARY REPAIRS TO UTILITY CUTS WILL BE AS PER MUNICIPAL4.
PERMITS FROM THE CITY'S RIGHT OF WAY MANAGEMENT UNIT.WAY THE CONTRACTOR SHALL OBTAIN ALL NECESSARY ROAD OCCUPANCYPRIOR TO COMMENCING ANY WORK WITHIN THE MUNICIPAL RIGHT OF5.
BE THE RESPONSIBILITY OF THE CONTRACTOR.ANY DAMAGE TO PROPERTY ADJACENT TO THE CONSTRUCTION SITE SHALL3.
TO THE CITY.PROPERTY OWNER IS OBTAINED AND SUBMITTED IN A FORMAT ACCEPTABLESHALL BE UNDERTAKEN UNLESS WRITTEN AGREEMENT WITH THE ADJACENTNO ALTERATIONS TO EXISTING BOUNDARY ELEVATIONS OR ADJACENT LANDS4.
NOISE BYLAW AND RAVINE AND NATURAL FEATURE PROTECTION BY-LAW.ALL CONSTRUCTION ACTIVITY SHALL COMPLY WITH CITY OF TORONTO6.
SHALL BE SUPPORTED ACCORDING TO CITY OF TORONTO DRAWING T-1007.01-4.ALL EXISTING WATERMAINS AND SEWER PIPES LARGER THAN 300 mm DIAMETER 17.
EQUIVALENT.GRADED AND SODDED. FILTER FABRIC FOR SILT CONTROL TO BE TERRAFIX 270R OR APPROVED TIME AS THE CURBS ARE CONSTRUCTED AND THE BOULEVARDS ARE SODDED OR BACKYARDS SILT TRAPS ARE SHALL BE CLEANED REGULARLY AND ARE NOT TO BE REMOVED UNTIL SUCH FILTER FABRIC SILT TRAPS SHALL PLACED UNDER GRATES ON ALL CATCHBASINS TO TRAP SEDIMENT. 6.
ANY FLOODING RESULTING FROM BLOCKED OR IMPAIRED DRAINAGE SYSTEMS.MAINTAINED AND REPLACED WHEN NECESSARY. CONTRACTOR SHALL BE RESPONSIBLE FOR EXISTING CATCH BASINS SHALL BE WRAPPED IN FILTER CLOTH WHICH WILL BE MONITORED, 7.
AREAS SHALL BE APPROVED BY TRCA.IN THE FLOODPLAIN OR WITHIN 30 m OF WATERCOURSE. EQUIPMENT STORAGE AND LAYDOWN ONSITE STORAGE: EQUIPMENT, MACHINERY, SITE TRAILERS CANNOT TYPICALLY BE STORED 13.
ABBREVIATIONS LEGEND
SANITARY MAINTENANCE HOLE
EXISTING TREE TO BE REMOVED
353
CIRCULAR CATCH BASIN
BUSH (CONIFEROUS)
CUT CROSS
HANDWELL (VARIOUS)
FIRE HYDRANT AND VALVE
LIGHT STANDARD
STORM SEWER MAINTENANCE HOLE COVER
PARKING METER
TV/ELECTRIC PEDESTAL
SANITARY MAINTENANCE HOLE COVER
SHRUB
SIB OR IB
SWAMP
WATER VALVE CHAMBER
VALVE
BENCH MARK
BOREHOLE
BRASS CAP
GAS VALVE
GAS VENT
FENCE GATE
GUY POLE
HORIZONTAL CONTROL MARKER
HEDGE
MARSH
POINT/TICK
EXISTING STORM SEWER
EXISTING WATERMAIN
EXISTING SANITARY SEWER
SANITARY SEWERPROPOSED XXmm
XXmm SANITARY SEWER
XXmm STORM SEWER
XXmm WATERMAIN
CPR
WV
G
HW
LS
PM
DOUBLE CATCH BASIN
SINGLE CATCH BASIN
SIGN
TREE STUMPSTUMP
PROPOSED TREE
TREE TO BE RETAINED AND PROTECTEDTREE IDENTIFICATION NUMBER
MINIMUM TREE PROTECTION ZONE (TPZ)
TREE CANOPY DRIPLINE
DECIDUOUS TREE
CONIFEROUS TREE
GATE VALVE
REGIONAL FLOOD LINE
EASEMENT LINE
THE SATISFACTION OF THE CITY OF TORONTO.COMMENCEMENT OF CONSTRUCTION AND APPROPRIATE ACTION TAKEN TOBE REPORTED TO THE CONTRACT ADMINISTRATOR PRIOR TO THE ANY DISCREPANCIES BETWEEN SITE CONDITIONS AND THE DRAWINGS MUST 2.
MEASURES TO BE KEPT ON SITE AND USED AS NECESSARY.AUTHORITY ENFORCEMENT OFFICE TO BE IMMEDIATELY CONTACTED. ADDITIONAL ESC MINIMIZE POTENTIAL ECOLOGICAL IMPACTS AND THE TORONTO REGION CONSERVATIONSUBSTANCE, THEN ALTERNATIVE MEASURES MUST BE IMPLEMENTED IMMEDIATELY TO MEASURES ON THE PLANS ARE NOT EFFECTIVE IN PREVENTING THE RELEASE OF A DELETERIOUS MINIMIZE SEDIMENT LADEN RUNOFF FROM LEAVING THE WORK AREA. IF THE PRESCRIBED STATIC AND MAY NEED TO BE UPGRADED/AMENDED AS SITE CONDITIONS CHANGE TO THE EROSION AND SEDIMENT CONTROL STRATEGIES OUTLINED ON THE PLANS ARE NOT 4.
REFUELING AND MAINTENANCE MUST BE CONDUCTED IN DESIGNATED AREAS.SUBSTANCES INTO NEARBY DITCHES, SWALES, STORM DRAINS OR WATERBODIES. VEHICLE TO PREVENT ENTRY OF PETROLEUM PRODUCTS, DEBRIS, CONCRETE OR OTHER DELETERIOUS ALL CONSTRUCTION ACTIVITIES INCLUDING MAINTENANCE PROCEDURES WILL BE CONTROLLED 5.
WEEKLY BASIS BEFORE LEAVING THE SITE FOR WEEKENDS.NECESSARY) OF ROADS ADJACENT TO THE PROJECT. IN ADDITION CLEAN ALL ROADS ON PROVIDE DUST CONTROL AT ALL TIMES INCLUDING THE MAINTENANCE AND CLEANUP (WHEN 10.
DIRT TRACKING ONTO ROADS.CLEAN OFF TRUCKS AND EQUIPMENT PRIOR TO LEAVING THE SITE TO PREVENT MUD AND 11.
PROVIDE SPILL CONTAINMENT CONTROL.12.
48 HOURS OF INSPECTION OR BOTH.SEDIMENT CONTROL MEASURES SHALL BE REPAIRED OR REPLACED WITHIN ENTRY OF SEDIMENT INTO THE WATERWAY AND SEWERS. ALL DAMAGED EROSION AND PRIOR TO, AND MAINTAINED DURING CONSTRUCTION PHASES, TO PREVENT EROSION AND SEDIMENT CONTROL (ESC) MEASURES SHALL BE IMPLEMENTED 1.
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
NO SCALE
RIGHT-OF-WAY
PROPERTY LINE
CPR/CNR MAINTENANCE HOLE COVER
GENERAL NOTES, ABBREVIATIONS AND LEGEND
NOTES
CH2M HILL, DATED APRIL 2015.FOR GEOLOGICAL AND HYDROLOGICAL INFORMATION REFER TO REPORT PREPARED BY 1.
COMMENCING CONSTRUCTION. (416-393-3302 OR [email protected]) AT LEAST 10 WORKING DAYS PRIOR TO OF A STREET CLOSURE, THE CONTRACTOR SHALL CONTACT MR. JOHN PRESSERDURING CONSTRUCTION, IN ORDER TO DIVERT ANY TTC SERVICE AS A RESULT 3.
OR [email protected]) FOR PARKS PERMIT.RECREATION. THE CONTRACTOR SHALL CONTACT JORGE TURE (416-394-5413CONSTRUCTION WORKS IN PARKS FROM THE CITY OF TORONTO PARKS, FORESTRY AND
THE CONTRACTOR SHALL OBTAIN A PARK ACCESS AGREEMENT FOR THE ACCESS AND
PARKS PERMIT:5.
OR [email protected]) AT LEAST 48 HOURS PRIOR TO COMMENCING CONSTRUCTION.LOCATION, THE CONTRACTOR SHALL CONTACT MR. JOHN PROSSER (416-393-3302 TIMES. IN ORDER TO TEMPORARILY RELOCATE ANY TTC BUS OR STREETCAR DURING CONSTRUCTION WHEEL TRANS ACCESS SHALL BE MAINTAINED AT ALL 2.
TEMPORARY BYPASS PUMPING TRENCH
JULY 22, 2015
W.S.L.
WM
VB
US
TRCA
TCB
STS
STA
S.S.L.
SAN
RD
RCP
PVC
PROP.
P.E.
OPSD
NO
NTS
N.S.L.
M.O.E.
MIN.
MH
I.P.
I.E.
I.D.
HOR
G.E.
FRP
EX
E.S.L.
ESC
DWG
DS
DR
DIA
D.I.
DCB
CONC.
C.S.P.
CL
C.E.
CB
ASTM
ASB CM
ADMINISTRATOR. SEE DETAIL SHEET C34.TREE PROTECTION TO BE INSTALLED IN LOCATIONS OUTLINED BY THE CONTRACT 11.
TORONTO WATER INSPECTOR MAY BE PRESENT. 416-392-9334 OR AT [email protected], AT LEAST 48 HOURS PRIOR TO EXCAVATION, SO THAT A CONTRACTOR SHALL NOTIFY TORONTO WATER, DIVISIONAL OPERATIONS SERVICES AT
DURING THE CONSTRUCTION CLOSE TO AN EXISTING SANITARY TRUNK SEWER, THEDIVISIONAL OPERATIONS SERVICES AT LEAST TWO (2) WEEKS PRIOR TO EXCAVATION. SEWERS" SHALL BE COMPLETED BY THE CONTRACTOR AND RECEIVED BY TORONTO WATER, TORONTO WATER'S FORM "CONSTRUCTION WORK NEAR CITY OF TORONTO TRUNK PRIOR TO ANY CONSTRUCTION ACTIVITY IN THE VICINITY OF A TRUNK SEWER, 4.
TRAFFIC LIGHT
REPLACED AT CONTRACTOR'S OWN EXPENSE.DAMAGED AREAS OF PAVEMENT AND SIDEWALKS SHALL BE REMOVED ANDREPAIR ANY DAMAGE DONE TO ROADS AND SITE DURING CONSTRUCTION.10.
IF DAMAGED DURING CONSTRUCTION AT CONTRACTOR'S OWN EXPENSE.WHETHER SHOWN OR NOT. REPAIR ITEMS TO THEIR ORIGINAL CONDITIONREMOVE OR DEMOLISH ALL ITEMS REQUIRED FOR NEW CONSTRUCTION12.
FROM THE CITY'S RIGHT-OF-WAY MANAGEMENT UNIT DISTRICT OFFICE.THE CONTRACTOR SHALL APPLY FOR AND OBTAIN A ROAD OCCUPANCY PERMIT PRIOR TO COMMENCING ANY WORK WITHIN THE MUNICIPAL RIGHT-OF-WAY, 1.
WEST STREET LINE
WATERMAIN
VALVE BOX
UPSTREAM
TORONTO AND REGION CONSERVATION AUTHORITY
TEMPORARY CONCRETE BARRIER
SANITARY TRUNK SEWER
STATION
SOUTH STREET LINE
SANITARY
RECORD DRAWING
REINFORCED CONCRETE PIPE
POLYVINYL CHLORIDE
PROPOSED
POLYETHYLENE
ONTARIO PROVINCIAL STANDARD DRAWING
NUMBER
NOT TO SCALE
NORTH STREET LINE
MINISTRY OF THE ENVIRONMENT AND CLIMATE CHANGE
MINIMUM
MAINTENANCE HOLE OR MANHOLE
INTERMEDIATE PRESSURE
INVERT ELEVATION
IDENTIFICATION
HORIZONTAL
GROUND ELEVATION
FIBERGLASS REINFORCED PLASTIC
EXISTING
EAST STREET LINE
EROSION AND SEDIMENTATION CONTROL
DRAWING
DOWN STREAM
DIMENSION RATIO
DIAMETER
DUCTILE IRON
DOUBLE CATCH BASIN
CONCRETE
CORRUGATED STEEL PIPE
CLASS
COVER ELEVATION
CATCH BASIN
AMERICAN SOCIETY OF TESTING AND MATERIALS
ASBESTOS CEMENT
PROPOSED SANITARY SEWER TO BE REHABILITATED
OF THE UTILITIES AT HIS OWN EXPENSE.UTILITIES IS NEEDED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATION DRAWINGS ARE ESSENTIALLY CORRECT, HOWEVER IF RELOCATION OF EXISTING WITHIN THE LIMITS OF THE WORK PRIOR TO EXCAVATION. IT IS BELIEVED THAT THE EXACT LOCATION AND ELEVATION OF EACH UTILITY AND APPURTENANCES SHALL BE RESPONSIBLE FOR CONTACTING ALL UTILITY OWNERS AND VERIFYING OVERHEAD OR UNDERGROUND UTILITY CONDUITS MAY NOT BE SHOWN. THE CONTRACTOR SANITARY AND STORM SEWERS, WATERMAINS, ELECTRICAL, TELEPHONE, AND OTHER 2.
ISSUED FOR TENDER
AFTER THE OPERATIONS FIELD MANAGER'S APPROVAL.NOT THE RESPONSIBILITY OF ENBRIDGE GAS DISTRIBUTION INC. AND CAN ONLY BE DONE OPERATIONS OF OUR ABANDONED GAS PLANT. REMOVAL OF THE ABANDONED GAS PLANT IS [email protected] TO FACILITATE VERIFICATION AND DE-WATERING CHRIS MCGIVERY - FIELD MANAGER, OPERATIONS @ 416-495-5750 OR EMAIL ABANDONED GAS PLANT DURING CONSTRUCTION, THE CONTRACTOR MUST CONTACT CONTRACTOR WILL BE EXPOSING THE ABANDONED GAS PLANT OR HAPPEN TO EXPOSE THE THERE IS AN ABANDONED GAS PLANT IN THE VICINITY OF YOUR PROPOSED WORK. IF THE 6.
HW
HW
HW
HW
HW
HW
HW
HW
HW
TT
T
T
T
TT
PARKING
PARKING
TR
EE
D
AR
EA
020770011
92
90
88
86
84
85
83
81
79
77
9
3
10-12
17
2732-2750
2724
2722
97
57
91
W.S.L.
E.S.L.
W.S.L.
E.S.L.9+80
9+80
10+00
10+25
10+50
10+75
11+00
11+25
11+50
11+75
12+00
12+25
12+50
WV*
*
N81.0
8
S81.0
8
N81.0
1
S80.9
6
N79.7
6
S79.6
7
E78.9
6S78.8
6
E80.9
5
E79.7
1
N78.8
4
83.7
6
83.7
5
83.3
4
83.0
0
82.6
9
82.4
7
82.4
5
82.3
0
82.2
0
82.0
2
82.0
9
82.0
0
81.7
8
81.4
8
10
+00.0
0
10
+25.0
0
10
+50.0
0
10
+75.0
0
11+
00.0
0
11+
25.0
0
11+
50.0
0
11+
75.0
0
12
+00.0
0
12
+25.0
0
12
+50.0
0
83.8
2
81.7
5N
78.6
8
S78.6
8
9+
80.4
4
9+
97.9
4
10
+94.9
8
11+
93.2
0
12
+28.4
0
MATC
HLIN
E S
EE D
WG C
2
203mm SANITARY TRUNK SEWER
254mm SANITARY TRUNK SEWER
305mm SANITARY TRUNK SEWER
BH7
MAPLE B
OU
LE
VA
RD
ALB
ANI STR
EET
DWIGHT AVENUE
STR
EET
MU
RRIE
LIMIT O
F C
ON
TR
AC
T
S
TR
EET
BU
RMIN
GH
AM
FIBRE OPTIC (BELL)
BELL
ROGERS
WATERABANDONED
ROGERS
BELL
150mm WATER
450mm STORM SEWER
BELL
GAS
ROGERS
UNKNOWN UTILITY
400mm WATER
1350mm STORM SEWER
450mm STORM SEWER
400mm WATER
600 mm STORM SEWER
BELL
150mm WATER
BELL
TORONTO HYDRO
ROGERS
900mm STORM SEWER
1500mm STORM SEWER
TORONTO HYDRO
450mm STORM SEWER
ROGERS
GAS
ROGERS
50mm GAS
ABANDONED WATER
50mm GAS
400mm WATER
900mm STORM SEWER
1500mm STORM SEWER
BELL
100mm WATER
32mm GAS
BELL
ROGERS
1500mm STORM SEWER
400mm WATER
600mm STORM SEWER
ROGERS
BELL
GAS
BELL
50mm GAS
ROGERS
TORONTO HYDRO
J.V. 15ECS-LU-06TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-4 C1
M.B.
N
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
252.1mUSING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
LAKE ONTARIO
179° 180°
203mm SANITARY SEWER
203mm SANITARY SEWER
229mm SANITARY SEWER
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
IIIIII
I
III
I
I
IIIIIII
MH324-028-1 (DETAILS ON SHEET C18)
MH324-027-1 (DETAILS ON SHEET C18)
MH324-026-1 (DETAILS ON SHEET C18)
BH7
ASPHALT
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
INVERT
TOP EL. 83.76MH324-028-1
TOP E
L. 82.47
MH324-0
27-1
TOP E
L. 82.09
MH324-0
26-1
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONGTOP EL. 83.82
MH2922504859
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
CLAY SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 203-305mm VITRIFIED
NOTES:
FILL
LEAN CLAY
WEATHERED SHALE
JULY 22, 2015
STR
EET
HE
MA
N
TOP E
L. 81.75
MH324-0
25A-1
MH324-025A-1 (DETAILS ON SHEET C18)
FROM MH324-028-1 TO MH324-025A-1
203mm SANITARY SEWER
203mm SANITARY TRUNK SEWER
TRUNK SEWER @ 0.53%63.6m- 305mm DIA. V.C. SANITARY
35.2m- 305mm DIA. V.C. SANITARY TRUNK SEWER @ 0.53%98.2m - 254mm DIA. V.C. SANITARY TRUNK SEWER @ 0.85% 97.0m - 203mm DIA. V.C. SANITARY TRUNK SEWER @ 1.24%
II
AC C
CC
C
ISSUED FOR TENDER
MH2922504859
-
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
3
T
T T
T
T
T
T
T
LS
LS
LS
LS
LS
LS
LS
LS
LS
LS
PARKING LOT
PARKING
PARKING
PARKING
PARKING
PARKING
TREED AREA
TREED AREA
020680622
020680621
E95
2732-2750
2724
2722
27202718
2716
2747
2731-2735
2727-2729
2725
2723
27212719
2711
2709
5
27072705
2705A2703
2701
2708
271027122714
2704
26972693-2697
2693
2687
2688
12+50
12+75
13+00
13+25
13+50
13+75
14+00
14+25
14+50
14+75
15+00
WV#
WV#
*
*
W78.1
0
E78.1
0
W77.9
8
E77.9
7
S78.3
4
N78.3
4
81.4
8
80.9
8
80.8
5
80.8
8
80.9
6
81.1
7
81.2
7
81.3
5
81.3
3
81.2
4
81.1
4
81.2
4
12
+50.0
0
12
+75.0
0
12
+92.0
1
13
+00.0
0
13
+25.0
0
13
+50.0
0
13
+75.0
0
14
+00.0
0
14
+25.0
0
14
+50.0
0
14
+64.8
6
14
+75.0
0
15
+00.0
0
81.1
7
MATC
HLIN
E S
EE D
WG C
3
MATCHLINE
SEE DWG C1
AVE
NU
ED
WIG
HT
762mm SANITARY TRUNK SEWER
762mm SANITARY TRUNK SEWER
N
J.V. 15ECS-LU-O6TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-5 C2
M.B.
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
150mm WATER
525mm STORM SEWER
150mm GAS
FIBRE OPTIC (TELUS)
BELL
UNKNOWN UTILITY
UNKNOWN UTILITY
300mm WATER
BELL
ROGERS
150mm WATER
2100mm STORM SEWER
150mm WATER
300mm WATER
BELL
ROGERS
300mm STORM SEWER
300mm WATER
1500mm STORM SEWER
900mm STORM SEWER
ROGERS
BELL
400mm WATER
100mm WATER
900mm STORM SEWER
BELL
ROGERS
FIBRE OPTIC (TELUS)
150mm GAS
150mm WATER
1800mm STORM SEWER
305mm SANITARY TRUNK SEWER
250.0m USING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
LAKE ONTARIO
99°161°
200mm SANITARY SEWER
200mm SANITARY SEWER200mm SANITARY SEWER
200mm SANITARY SEWER
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
CCCCCCCCC I
A A A A
A A A A A A
A
A
C
CC
CCCC
CC
C
C
I
C
CA
C
CA
SAN MH11
250mm SANITARY SEWER
SAN MH
LAKE SHORE B
OULEVARD W
(DETAILS ON SHEET C17)MH324-025-1
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
LANE MARKING (WHITE)
LANE MARKING (YELLOW)
LANE MARKING (WHITE)
TTC TRACK CL (EASTBOUND)
TTC TRACK CL (WESTBOUND)
FROM MH324-025-1 TO MH324-024-1
TOP E
L. 80.85
MH324-0
25-1
TOP E
L. 81.17
MH324-0
24-1
INVERT
MH324-024-1 (DETAILS ON SHEET C17)
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG
RO
AD
SA
ND B
EA
CH
SANITARY SEWER762mm
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
AND 762mm CLAY TILE SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 305mm VITRIFIED CLAY
NOTES:
TRUNK SEWER @ 0.14%141.35m - 762mm DIA. CLAY TILE SANITARY
172.9m - 762mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.07%63.6m - 305mm DIA. V.C. SANITARY TRUNK SEWER @ 0.53%
JULY 22, 2015
I
I
A
C
C
C
C
ISSUED FOR TENDER
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
HW
HW
HW
HW
HW
HW
HW
HW
HW
2642
2644
7
14
12
10
11
13
17
PARKING
TREED AREA
TREED AREA
020680615
E115
2687
26862682
26852679
2677
2675 2667
2680 2678
2676
2674
26722670
2663
26662660
6
26492647
5
2
2656
2654
2652
26502648
2643
2645
8
6
4
15+00
15+25
15+50
15+75
16+00
16+25
16+50
16+75
17+00
17+25 17+50
*
*
HW
N77.8
2
S77.8
2
S77.5
8N
77.5
9
E78.1
2W
78.5
0
81.2
4
81.2
3
81.2
1
81.3
1
81.3
6
81.0
2
80.7
8
80.6
4
80.5
2
80.5
0
80.5
1
80.5
9
80.6
9
15
+00.0
0
15
+25.0
0
15
+50.0
0
15
+75.0
0
16
+00.0
0
16
+06.2
1
16
+25.0
0
16
+50.0
0
16
+75.0
0
17
+00.0
0
17
+07.6
2
17
+10.5
0
17
+25.0
0
17
+50.0
0
81.3
1
E78.3
6
N77.4
1S77.5
6
MATC
HLIN
E S
EE D
WG C
4
MATC
HLIN
E S
EE D
WG C
2
762mm SANITARY TRUNK SEWER
RO
YAL Y
OR
K R
OA
D
RO
YAL Y
OR
K R
OA
D
J.V. 15ECS-LU-06TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-6 C3
M.B.
N
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
150mm WATER
600mm STORM SEWER
750mm STORM SEWER
50mm GAS
450mm STORM SEWER
100mm GAS
ROGERS
675mm STORM SEWER
BELL
ROGERS
BELL
150mm WATER
FIBER OPTIC (TELUS)
100mm GAS
100mm GAS
TORONTO HYDRO
BELL
ROGERS
525mm STORM SEWER
FIBER OPTIC (TELUS)
150mm GAS
150mm WATER
300mm WATER
150mm WATER
ROGERS
BELL
300mm WATER
600mm STORM SEWER
ROGERS
BELL
150mm WATER
450mm STORM SEWER
675mm STORM SEWER
BELL
ROGERS
600mm STORM SEWER
150mm WATER
300mm WATER
200mm WATER
150mm WATER
(TELUS)FIBRE OPTICS
100mm GAS
HYDROTORONTO
STORM SEWER300mm
250.0m USING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
LAKE ONTARIO
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
176°
178°
171°
225mm SANITARY SEWER
375mm SANITARY SEWER
200mm SANITARY SEWER
200mm SANITARY SEWER
200mm SANITARY SEWER
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
C
C
A
I
CI
I
C
A
A
A A
C
C
A
A
I
C
C
AI
CC
C
C
C
C
C
C
A
CC
A
I
C
I
I
I
I
A
LAKE SHORE BOULEVARD W
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
762mm SANITARY TRUNK SEWER
LANE MARKING (WHITE)
TTC TRACK CL (WESTBOUND)
LANE MARKING (YELLOW)
LANE MARKING (WHITE)
TTC TRACK CL (EASTBOUND)
FROM MH324-023-1 TO MH324-021-1
INVERT
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG
(DETAIL ON SHEET C17)MH324-023-1
SEWER250mm SANITARY
STORM SEWER525mm
TRUNK SEWER915mm SANITARY
ON SHEET C17)(DETAIL MH324-022-1
(DETAIL ON SHEET C16)MH324-021-1
TRUNK SEWER915mm SANITARY
DWG C20SEE DETAIL
SANITARY TRUNK SEWER @ 0.02%102.20m - 915mm DIA. CLAY TILE
SANITARY TRUNK SEWER @ 1.03%2.88m - 915mm DIA. CLAY TILE
101.4m - 762mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.14% 141.35m - 762mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.11%
TOP E
L. 81.31
MH324-0
23-1
TOP E
L. 80.50
MH324-0
22-1
JULY 22, 2015
450mm SANITARY SEWER
229mm SANITARY SEWER
TOP E
L. 80.51
MH324-0
21-1
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE/PARKING LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 762-915mm CLAY TILE
NOTES:
ISSUED FOR TENDER
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
2636
2634
2614
2616
2612
2609
2613
2615
2619
2627
2626
2620
2618
2622
2624
2630
2632
2638
2640
2642
2637
T
T
T
T
T
T
T
T
T
T
T
T
T
TREE
D
ARE
A
TREE
D
ARE
A
E116020680614
020720756
2643
2641
17+50
17+75
18+00
18+25
18+50
18+75
19+00
19+25 19+50 1
9+75 2
0+00
S77.3
9
N77.3
8
S77.1
7
N77.1
7
80.6
9
80.7
2
80.7
7
80.8
3
80.8
9
81.0
0
81.0
9
81.2
3
81.2
5
81.2
8
81.3
8
81.4
6
81.5
9
17
+50.0
0
17
+75.0
0
18
+00.0
0
18
+12.7
0
18
+25.0
0
18
+50.0
0
18
+75.0
0
19
+00.0
0
19
+25.0
0
19
+31.1
8
19
+50.0
0
19
+75.0
0
20
+00.0
0
MATC
HLIN
E S
EE D
WG C
5
MATC
HLIN
E S
EE D
WG C
3 BH6
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
J.V. 15ECS-LU-06TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-7 C4
M.B.
N
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
150mm WATER
300mm STORM SEWER
300mm WATER
ROGERS
450mm STORM SEWER
150mm WATER
100mm GAS
TORONTO HYDRO
TORONTO HYDRO
ROGERS
100mm GAS
150mm WATER
300mm WATER
250mm STORM SEWER
150mm WATER
250.0m USING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
LAKE ONTARIO
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
165° 165°
200mm SANITARY SEWER200mm SANITARY SEWER
A
I
I
A
II
I
I
A
I
I
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
C
C
C
C
AAI
C
AI
C
A
A
C
A
I
I
A
AI
C
A
C
A
C
C
BOULEVARD WLAKE SHORE
BH6
ASPHALTCONCRETEFILL
FILL
WEATHERED SHALE
MH324-020-1 (DETAILS ON SHEET C12)
SHEET C12)(DETAILS ON MH324-019-1
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
TRUNK SEWER915mm SANITARY
200mm SANITARY SEWER
LANE MARKING (WHITE)
TTC TRACK CL (WESTBOUND)
LANE MARKING (YELLOW)
LANE MARKING (WHITE)
TTC TRACK CL (EASTBOUND)
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG
INVERT
FROM MH324-020-1 TO MH324-019-1
TOP E
L. 80.83
MH324-0
20-1
TOP E
L. 81.28
MH324-0
19-1
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE
NOTES:
115.4m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%118.5m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.18% 102.20m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.02%
JULY 22, 2015
ISSUED FOR TENDER
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
2577
2581X
2580
2582
2610
A
2612
2610
2606
2604
2608
2602
2600
2597
2609
2607
2603
2595
2598
2596
2594
2591
2585
2588
2586
2584
2583
T
T
T
T
T
T
T
T
T
T
T
T
T
T
LS
LS
LS
LS
LS
LS
LS
LS
TR
EE
D
AR
EA
E116
020810129
020680613
020720755
20+00
20+25
20+50
20+75
21+00
21+25
21+50
21+75 22+00 22+25 22+50
*
#
S77.0
6
N77.0
5
S76.9
0
N76.8
9
81.5
9
81.6
0
81.6
0
81.5
3
81.4
5
81.2
8
81.0
0
81.0
8
81.1
3
81.1
8
81.3
4
81.4
7
20
+00.0
0
20
+25.0
0
20
+46.6
3
20
+50.0
0
20
+75.0
0
21+
00.0
0
21+
25.0
0
21+
50.0
0
21+
61.0
8
21+
75.0
0
22
+00.0
0
22
+25.0
0
22
+50.0
0
81.6
5
E77.2
6W
77.3
4
MATC
HLIN
E S
EE D
WG C
6
MATC
HLIN
E S
EE D
WG C
4
BH4
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
LA
KE C
RES
CE
NT
LAKE C
RESCENT
J.V. 15ECS-LU-06TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-8 C5
M.B.
N
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
150mm WATER
300mm WATER
150mm WATER
675mm STORM SEWER
50mm GAS
150mm WATER
250mm STORM SEWER
300mm WATER
ROGERS
150mm WATER
ROGERS
300mm WATER
150mm WATER
100mm GAS
TORONTO HYDRO
TORONTO HYDRO
FIBRE OPTIC (TELUS)
675mm STORM SEWER
50mm GAS
150mm WATER
100mm GAS
TORONTO HYDRO
TORONTO HYDRO
BELL
TORONTO HYDRO
100mm GAS
150mm WATER
ROGERS
250.0m USING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
LAKE ONTARIO
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
173° 169°
200mm SANITARY SEWER
200mm SANITARY SEWER
200mm SANITARY SEWER
200mm SANITARY SEWER
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
C
CC
C
AA
CC
C
C
AC
CAC
AC
A
C
C
C
C
A
A
CC
C
A C
CA
C
C
C
C
A
C
C
LAKE SHORE BOULEVARD W
200mm SANITARY SEWER
BH4
ASPHALT
FILL
LEAN CLAY
WEATHERED SHALE
MH324-018-1 (DETAILS ON SHEET C12)MH324-017-1 (DETAILS ON SHEET C12)
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
LANE MARKING (WHITE)
TTC TRACK CL (WESTBOUND)
LANE MARKING (YELLOW)
LANE MARKING (WHITE)
TTC TRACK CL (EASTBOUND)
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG
FROM MH324-018-1 TO MH324-017-1
INVERT
TOP E
L. 81.65
MH324-0
18-1
TOP E
L. 81.08
MH324-0
17-1
TRUNK SEWER915mm SANITARY
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE
NOTES:
146.10 - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%114.5m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.13% 115.4m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.18%
JULY 22, 2015
ISSUED FOR TENDER
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
HW
2555
6
8
10
20
18
2545
2543
25542
556
2560
2558
42
2563
2561
2562
11
9
5
2564
2566
2570
2574
2572
2571
2567
2577
2575
2573
2578
2576
2565
T
T
T
TT
T
T
T
T
LS
LS
LS
LS
LSLS
LS
LS
LS LS
TR
EE
D
AR
EA
TR
EE
D
AR
EA
TR
EE
D
AR
EA
TR
EE
D
AR
EA
020700084020810126020680613
22+50
22+75
23+00
23+25
23+50
23+75
24+00
24+25
24+50
24+75
25+00
WV
WV#
WV
MHBELL
GV
S76.7
5
N76.7
5
S76.7
3
N76.7
2
S76.6
6N
76.6
6
S76.6
0
N76.6
0
S76.5
8
N76.5
8
81.4
7
81.5
2
81.4
4
81.5
0
81.3
6
81.2
5
81.2
8
81.1
8
81.2
3
81.2
5
81.4
0
81.6
5
81.8
0
81.9
7
82.0
3
82.3
7
22
+50.0
0
22
+75.0
0
23
+00.0
0
23
+07.1
9
23
+25.0
0
23
+41.3
4
23
+50.0
0
23
+75.0
0
23
+97.4
2
24
+00.0
0
24
+25.0
0
24
+50.0
0
24
+62.1
0
24
+75.0
0
24
+79.1
0
25
+00.0
0
E77.3
2W
77.4
1
E78.3
9W
77.4
0
E77.3
9
E77.5
1
MATC
HLIN
E S
EE D
WG C
7
MATC
HLIN
E S
EE D
WG C
5
915mm SANITARY TRUNK SEWER
900mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
SY
MO
NS S
TREET
MIL
ES R
OA
D
J.V. 15ECS-LU-06TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-9 C6
M.B.
N
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
150mm WATER
TORONTO HYDRO
1350mm STORM SEWER
TORONTO HYDRO
150mm WATER
300mm WATER
STORM SEWER (NO FLOW)
BELL
ROGERS
100mm GAS
375mm STORM SEWER
UNKNOWN UTILITY
ROGERS
150mm WATER
100mm GAS
GAS
300mm WATER
ROGERS
32mm GAS
150mm GAS
100mm GAS
TORONTO HYDRO
150mm WATER
300mm WATER
BELL
ROGERS
150mm WATER
BELL
150mm WATER
GAS
300mm WATER
ROGERS
150mm WATER
STORM SEWER (NO FLOW)
BELL
32mm GAS
ROGERS
100mm GAS
BELL
150mm WATER
TORONTO HYDRO
1350mm STORM SEWER
TORONTO HYDRO
100mm GAS150mm WATER
300mm WATER
ROGERS
250.0m USING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
LAKE ONTARIO
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
179°181°
181°
179°178°
305mm SANITARY SEWER
300mm SANITARY SEWER
300mm SANITARY SEWER
300mm SANITARY SEWER
200mm SANITARY SEWER
203mm SANITARY SEWER
200mm SANITARY SEWER
300mm STORM SEWER
200mm SANITARY SEWER
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
A I
C
C A
C
C A
C
C
A
CA
C
C
A
C
C
C
C C
C
C
C
C
A
C
LAKE SHORE BOULEVARD W
MH324-016-1 (DETAILS ON SHEET C12)
MH324-015-1 (DETAILS ON SHEET C12)
MH324-014-1 (DETAILS ON SHEET C12)
MH324-015A-1 (DETAILS ON SHEET C15)
SHEET C14)(DETAILS ON MH324-014A-1
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
LANE MARKING (WHITE)
TTC TRACK CL (WESTBOUND)
LANE MARKING (YELLOW)
(EASTBOUND)TTC TRACK CL
(WHITE)LANE MARKING
INVERT
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG
FROM MH324-016-1 TO MH324-014A-1
TOP E
L. 81.50
MH324-0
16-1
TOP E
L.81.25
MH324-0
15-1
TOP E
L. 81.80
MH324-0
14-1
TRUNK SEWER @ 0.10% CLAY TILE SANITARY 70.3m - 915mm DIA.
TRUNK SEWER @ 0.10% CLAY TILE SANITARY 17.0m - 915mm DIA.
64.7m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10% 56.1m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10% TRUNK SEWER @ 0.09%34.2m - 915mm DIA. CLAY TILE SANITARY
146.10m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%
120.8m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER TRUNK SEWER 87.3m- 915mm DIA. CLAY TILE SANITARY
JULY 22, 2015
356mm SANITARY SEWER
254mm SANITARY SEWER
UNKNOWN SANITARY SEWER
SEWER203mm SANITARY
SEE NOTE 4
(SEE N
OTE 5)
TOP E
L. 81.23
MH324-0
15A-1
(SEE N
OTE 5)
TOP E
L. 82.03
MH324-0
14A-1
5. NO FULL ACCESS TO TRUNK FROM MH324-15A-1 AND MH324-14A-1
MAINTAIN TIME OR SPACE SEPERATION. BE REPLACED IN 2015-2016. COORDINATE CONSTRUCTION TO4. EXISTING WATERMAIN ON SYMONS STREET IS PRPOSED TO
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE
NOTES:
TORONTO HYDRO
ISSUED FOR TENDER
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
HW
HW
HW
HW
2517
42
20
2519
2521
2515
2524 2
522
2518
2516
25202532
2536
2500
2502
2510
25122
514
2506
2508
2504
2501
2513
2507
2499
2546
T
T
TT
T
T
T
T
T
TT
T
T
T
LS
LS LS
LS
LS
LS
LS
LSLS
LS
LS
LS
LS
LS
LS
LS
LS
LS
FP
LS PARKING
PARKING
TR
EE
D
AR
EA
TR
EE
D
AR
EA
TR
EE
D
AR
EA
E118
020680612
020810120
25+00
25+25
25+50
25+75
26+00
26+25
26+50
26+75
27+00
27+25
27+50
WV
WV
WV
# *#
HW
HW
HW
HW
HW
S76.5
1
N76.5
1
S76.4
6
N76.4
6
S76.4
4
N76.4
4
S76.4
1
N76.3
9
S76.3
9
N76.3
9
S76.3
2
N76.3
2
82.3
7
82.5
7
82.7
3
82.6
3
82.5
1
82.5
0
82.3
3
82.2
9
81.9
2
81.7
5
81.4
581.4
3
80.9
0
80.4
7
80.3
1
80.1
5
25
+00.0
0
25
+25.0
0
25
+49.4
225
+50.0
0
25
+75.0
0
25
+88.7
2
26
+00.0
0
26
+03.4
2
26
+19.3
9
26
+25.0
0
26
+50.0
0
26
+59.7
8
26
+73.8
326
+75.0
0
27
+00.0
0
27
+25.0
0
27
+36.5
9
27
+50.0
0
S76.4
7
N76.4
7
82.7
3
E77.0
0
E78.9
8
82.3
3
E76.9
0W
77.0
5
E78.8
5
W78.7
0
E78.5
0
E76.8
7W
77.6
0
MATC
HLIN
E S
EE D
WG C
8
MATC
HLIN
E S
EE D
WG C
6
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
BH3
QUEE
NS AV
ENUE
DO
UG
LAS B
OU
LE
VA
RD
NO
RRIS C
RES
CE
NT
HIL
LSID
E A
VE
NU
E
TRUNK SEWER915mm SANITARY
RO
AD
SU
MM
ER
HIL
L
J.V. 15ECS-LU-06TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-10 C7
M.B.
N
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
ROGERS
TORONTO HYDRO
50mm GAS
200mm WATER
BELL
BELL
150mm WATER
TORONTO HYDRO
ROGERS
WATER
ROGERS
TORONTO HYDRO
150mm WATER
TORONTO HYDRO
50mm GAS
BELL
ROGERSABANDONED WATER
3600 x 2400mm STORM SEWER
WATER
100mm GAS
GAS
BELL
ROGERS
150mm WATER
BELL
GAS
300mm WATER
ROGERS
300mm STORM SEWER
150mm WATER
150mm GAS
100mm GAS
WATER
3600 x 2400mm STORM SEWER
150mm WATER
150mm GAS
ROGERS
150mm WATER
TORONTO HYDRO
250mm STORM SEWER
150mm GAS
BELL
TORONTO HYDRO
250mm STORM SEWER
300mm WATER
150mm WATER
150mm GAS
50mm GAS
ROGERS
WATERABANDONED
LAKE ONTARIO
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
180° 179°
176°
177°182° 179° 181°
200mm SANITARY SEWER
200mm SANITARY SEWER
ABANDONED SANITARY SEWER
250mm SANITARY SEWER
300mm SANITARY SEWER
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
A
C
A
A
C
C
C
C
A
C
C
A
C C
C C
A
C C
AC
C
C
C
A
C IC
A
LAKE SHORE BOULEVARD W
BH3
250mm SANITARY SEWER
ASPHALTFILL
LEAN CLAY
SEWERSANITARY250mm
SEWERSANITARY250mm
250mm SANITARY SEWER
SEWERSANITARY 250mm
SEWERSANITARY357mm
MH324-013-1 (DETAILS ON SHEET C12)
SHEET C13)(DETAILS ONMH324-010-1
MH324-011-1 (DETAILS ON SHEET C14)
MH324-012-1 (DETAILS ON SHEET C13)
(DETAILS ON SHEET C13)MH324-008-1
MH324-009-1 (DETAILS ON SHEET C13)
SHEET C12)(DETAILS ON MH324-007-1
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
SEWERSANITARY250mm
LANE MARKING (WHITE)
TTC TRACK CL (EASTBOUND)
LANE MARKING (YELLOW)
TTC TRACK CL (WESTBOUND)
LANE MARKING (WHITE)
FROM MH324-013-1 TO MH324-007-1
INVERT
150mm GAS
TOP E
L. 82.73
MH324-0
13-1
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG
TOP E
L. 80.31
MH324-0
07-1
ALL SERVICE CONNECTIONSINSTALL TOP HATS ON
236.6m USING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
87.3m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER 187.3m- 915mm DIA. CLAY TILE SANITARY TRUNK SEWER
JULY 22, 2015
LINER @ 0.11%WITH EXISTING CIPPSANITARY TRUNK SEWER 95.3m - 915mm DIA. CLAY TILE
62.8m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.10%
SANITARY TRUNK SEWER @ 0.10%14.0m - 915mm DIA. CLAY TILE
TRUNK SEWER @ 0.11%40.4m - 915mm DIA. CLAY TILE SANITARY
SANITARY TRUNK SEWER @ 0.11%16.0m - 915mm DIA. CLAY TILE
SANITARY TRUNK SEWER @ 0.09%14.7m - 915mm DIA. CLAY TILE
TRUNK SEWER @ 0.09%39.30 - 915mm DIA. CLAY TILE SANITARY
70.3m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 0.09%
SHALEWEATHERED
TRUNK SEWER915mm SANITARY
(SEE N
OTE 4)
TOP E
L. 82.51
MH324-0
12-1
(SEE N
OTE 4)
TOP E
L. 82.33
MH324-0
11-1
(SEE N
OTE 4)
TOP E
L. 82.33
MH324-0
10-1
(SEE N
OTE 4)
TOP E
L. 81.75
MH324-0
09-1
(SEE N
OTE 4)
TOP E
L. 81.45
MH324-0
08-1
4. NO FULL ACCESS TO TRUNK FROM MH324-012-1 TO MH324-008-1
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE
NOTES:
ISSUED FOR TENDER
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
HW
HW
HW
1
2441
2435-2437
2435
2415
2413
4A
2432
1
2428
2424-2426
2420-2422
2434-2436
2430
2430-2432
2438
2448
2444-2446
2442
6
4
6A
1
2492249424
962498
2500
2499
2497
2491
2485-2489
2483
2472
2480
2454
2458
2456
2449-2481
2457
2455
2445
2427
2423-2425
2409-2411
2407
2405
2413
R
T
T
T
T
T
T
T
T
LS
LS LS
LS
LS
LS
LS
LS
LS
LS
LS LS
LS
LS LS
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
TR
EE
D
AR
EA
PA
RKIN
G
PA
RKIN
G
02068610R
020700085
020680610
27+50 27+75 28+00 28+25
28+50
28+75
29+00
29+25
29+50
29+75
30+00
*
HW
S76.2
2
N76.2
1
S74.5
0
N74.5
0
S74.2
2
N74.2
1
80.1
5
79.8
9
79.7
2
79.5
2
79.4
6
79.1
9
78.7
0
78.2
0
77.4
0
77.3
1
77.2
9
77.3
5
27
+50.0
0
27
+75.0
0
28
+00.0
0
28
+25.0
0
28
+31.8
8
28
+50.0
0
28
+75.0
0
29
+00.0
0
29
+25.0
0
29
+35.9
7
29
+50.0
0
29
+62.4
3
29
+75.0
0
30
+00.0
0
77.5
9
77.7
6
W75.6
5
W74.7
5
MATC
HLIN
E S
EE D
WG C
7
MATC
HLIN
E S
EE D
WG C
9
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
915mm SANITARY TRUNK SEWER
ALLEN A
VEN
UE
MIMIC
O A
VENUE
PRIM
ROSE A
VE
NU
E
J.V. 15ECS-LU-06TT
1 07-22-2015
PLAN AND PROFILE
1058-2013-19-11 C8
M.B.
N
ARE IN METERS UNLESS OTHERWISE NOTED
MEASUREMENTS SHOWN ON THESE PLANS
METRIC
TORONTO HYDRO
ABANDONED GAS
150mm WATER
150mm GAS
250mm STORM SEWER
32mm GAS
BELL
UNKNOWN UTILITY
300mm STORM SEWER
150mm WATER
ABANDONED GAS
150mm WATER
TORONTO HYDRO
150mm GAS
300mm STORM SEWER
ROGERS
300mm WATER
600mm STORM SEWER50mm GAS
ROGERS
ABANDONED GAS
150mm WATER
TORONTO HYDRO
750mm STORM SEWER
FIBRE OPTIC (ROGERS)
BELL
150mm GAS
375mm STORM SEWER
150mm WATER
300mm WATER
150mm WATER
300mm STORM SEWER
32mm GAS
BELL
ROGERS
TORONTO HYDRO
150mm WATER
BELL
ROGERS
300mm STORM SEWER
150mm WATER
BELL
ROGERS
TORONTO HYDRO
50mm GAS
250mm STORM SEWER
300mm WATER
ROGERS
LAKE ONTARIO
LAKE SHORE SANITARY TRUNK SEWER
REHABILITATION
194° 181°
180°
225mm SANITARY SEWER
300mm SANITARY SEWER
300mm SANITARY SEWER
250mm SANITARY SEWER
250mm SANITARY SEWER200mm SANITARY SEWER
200mm SANITARY SEWER
LEGEND:
ACTIVE CONNECTION
INCONCLUSIVE CONNECTION
CAPPED CONNECTION
A
I
C
A
A AA
A
A
A
A
A
A
A
A
A
A
C
C
CAAI
C
IC
C
C
A
C
A
CC
I
C A
C
A
C
C
C A
C
C
C C
C
30+00
LAKE SHORE BOULEVARD W
254mm SANITARY SEWER
MH324-004-1 (DETAILS ON SHEET C12)
MH324-005-1 (DETAILS ON SHEET C12)
MH324-006-1 (DETAILS ON SHEET C12)
JOHN KELLY, P. ENG.
DIRECTOR,
LINEAR UNDERGROUND INFRASTRUCTURE
DIRECTOR,
GRAHAM HARDING, P.ENG.
WATER INFRASTRUCTURE MANAGEMENT
DIRECTOR,
OPERATIONAL SUPPORT
RICHARD NOEHAMMER, P.ENG.
SIGNEDINITIALREVISIONSDATENo.
ENGINEERING AND CONSTRUCTION SERVICES
DESIGN:
DATE:
SCALE:
DRAFTING: CHECK:
DRAWING
NUMBER:
CHECKED CONTRACT No.
Water
HOR 1:500, VERT 1:100
EXISTING
GROUND
ELEVATION
ELEVATION
CHAINAGE
65m
DATUM ELEV.
70m
75m
80m
85m
LANE MARKING (WHITE)
TTC TRACK (EASTBOUND)
LANE MARKING (YELLOW)
TTC TRACK (WESTBOUND)
LANE MARKING (WHITE)
INVERT
FROM MH324-006-1 TO MH324-004-1
SANITARY SEWERCENTRE LINE OF EXISTINGEXISTING GROUND ALONG
TOP E
L. 79.46
MH324-0
06-1
TOP E
L. 77.59
MH324-0
05-1
TOP E
L. 77.31
MH324-0
04-1
168.1m USING CIPP LINER
WITH TRENCHLESS TECHNOLOGYREHABILITATE SANITARY SEWER
INSTALL TOP HATS ON ALL SERVICE CONNECTIONS
MAINTENANCE HOLES WHERE CONTRACTOR IS WORKING.3. PARTIAL LANE CLOSURE WILL BE PERMITTED ONLY BETWEEN
TO SINGLE LANE.2. BYPASS PIPE AND ALL EQUIPMENT TO BE RESTRICTED
SANITARY SEWER UTILIZING CIPP LINING.1. REHABILITATE THE EXISTING 915mm CLAY TILE
NOTES:
TRUNK SEWER @ 0.15%109.3m - 915mm DIA. CLAY TILE SANITARY
TRUNK SEWER @ 1.06%26.5m - 915mm DIA. CLAY TILE SANITARY
104.1m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER @ 1.64% WITH EXISTING CIPP LINER @ 0.11%95.3m - 915mm DIA. CLAY TILE SANITARY TRUNK SEWER
JULY 22, 2015
ISSUED FOR TENDER
KEY PLAN(NOT TO SCALE)
AV
EN
UE
DWIG
HT
ALBA
NI STR
EET
MURRIE
STRE
ET
STRE
ETBURMING
HAM
BOUL
EVAR
DMA
PLE
MILES RO
AD
STREETS
YMONS
QU
EE
NS
AV
E
AVENUEALLEN
MIMICO AV
ENUE
AVENUEPR
IMROSE
AVENUE
SUPERIOR
AVENUE
SUPERIOR
SYMO
NS S
TREET
LAKE
CRES
ELMA
STRE
ET
STRU
THER
S ST
REET
LAKE
CRES
STRU
THER
S ST
REET
EAS
TB
OU
RN
E
CR
ES
DA
RT
MO
UT
H
CR
AV
EN
UE
DWIG
HT
AV
EN
UE
DWIG
HT
SE
CO
ND
ST
THIR
D
ST
RE
ET
FO
UR
TH S
TR
EE
T
FIF
TH S
TR
EE
T
SIX
TH S
TR
EE
T
SE
CO
ND
ST
THIR
D
ST
BLVDS
HOREL
AKE
BLVDS
HOREL
AKE
STRE
ETBURMING
HAM
STREETS
YMONS
AVENUEM
IMICO
AVENUEH
ILLSID
E
AVENUEH
ILLSID
E
STANLE
YAVENU
E
CAVELL AV
ENUE
NORRIS CRES
DOUGLAS BLVD
SUMMERHILL RD
QU
EE
NS
AV
E
WH
EA
TFIE
LD
RD
CE
NT
RA
L S
TR
EE
T
GE
OR
GE S
TR
EE
T
RO
YA
L
YO
RK
RO
AD
RO
YA
L
YO
RK
RO
AD
GE
OR
GE S
TR
EE
T
ELIZ
AB
ET
H S
TR
EE
T
ST
ATIO
N
RD
ST
ATIO
N
RD
FIR
ST
ST
SA
ND
BE
AC
H
RD
RO
YA
L
YO
RK
RO
AD
BLVD
ISLAND VIEW
CRESL
AKE
EDYTH COURT
RO
AD
WH
EA
TFIE
LD
N
BLVD W.
LAKE
SHOR
E
BO
ULE
VA
RD
W.
LA
KE S
HO
RE
HEMAN S
TREET
2389-2391
9
11
2404-2406
2408
2412
2410
241624
18
2428
2424-2426
2420-2422
2403
2405
2401 2399
2389
A-2391A
2389
B-2391B
2392-2398
2388
A-2390
A
2383-2387
2386
A
2388
B-2390
B
2388-2390
2386
LS
LS
LS
LS
LS
LS
LS
LS
LS
PA
RKIN
G
PA
RKIN
G
PA
RKIN
G
PA
RKIN
G
PA
RKIN
G
PA
RKIN
G
PA
RKIN
G
PA
RKIN
G
PARKING
E120
30+0