Operator’s Guide WATER ION TECHNOLOGIES 10-CELL MACHINE Exclusive Manufacturer WITBM-OG-0415 w t WATER ION TECHNOLOGIES

WATER ION 10 Cell Machine...Reservoir Level Indicator of the Reservoir Tank located on the right hand side of the 10-Cell Machine. Ensure the water level is above the minimum fill

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WATER ION 10 Cell Machine...Reservoir Level Indicator of the Reservoir Tank located on the right hand side of the 10-Cell Machine. Ensure the water level is above the minimum fill

Operator’sGuide

WATER

ION

TECH

NO

LOG

IES 10-CELL

MACH

INEExclusive Manufacturer

WITBM-OG-0415

w tWATER ION TECHNOLOGIES

Page 2: WATER ION 10 Cell Machine...Reservoir Level Indicator of the Reservoir Tank located on the right hand side of the 10-Cell Machine. Ensure the water level is above the minimum fill

SECTION 1: Unit Components Top (Figure 1): Gas Output Port Water Tower Lid Water Tower Gas Input Line Gas Safety Shutoff Valve Water Tower and Base Multicolor LED Light Water Tower Light Base Fill Cap of Reservoir Tank Fill Neck Reservoir TankBack (Figure 2): Power Cord Power Cord Hook Power Cord Strain Relief Cabinet Fans (Upper and Lower) Internal Dryer Drain ValveFront (Figure 3): Main Power Switch Power Supply Green Indicator Light Red Indicator Light System Pressure Gauge Hour Meter Push Bars Right Side (Figure 4): External Water Trap Reservoir Level Indicator

(Fig. 1)

Water Ion Technologies 10-Cell MachineOperator’s Guide

Important Unit Operation and Safety Information• Read all instructions carefully before operation.• This machine must be properly installed and located in accordance with these instructions before it is operated.• Do not place on or near hot surfaces.• To prevent fire, electrical shock and injury, do not immerse cords or plugs in water or any other liquids. • Do not use outdoors. Operate the machine in a moisture-free environment a safe distance from any source of liquids. An ambient

indoor temperature range between 70o and 85o F is preferred.• Do not fill the reservoir tank above the max fill line.• Use only distilled water to fill the reservoir tank and the water tower. Watt-Ahh® is recommended if available in your area (order at aquanew.com).• Turn off and unplug the unit when not in use. • For best operation, plug the unit into a dedicated outlet. Ensure the outlet is correctly rated for the unit in operation.• Do not operate the machine if the power cord or plug are damaged in any way. For assistance, please call 303.355.9696.• Close supervision is necessary when any unit is used by or near children.• Do not use this machine for anything other than its intended use.• Follow the startup procedure before each use.• This unit has a scheduled service program, to be performed only by the authorized service company. • Contact customer service or technical assistance with any additional questions, comments or concerns (call 303.355.9696).

SECTION 2: Unit Pre-Startup Checklist• Ensure the Main Power Switch (Fig. 3) on the front panel of the machine is in the OFF position and the Green Indicator Light (Fig. 3) is not ON.• On the Power Supply (Fig. 3) rotate clockwise the three of four control knobs located closest to the right side of the machine until they stop. Rotate counterclockwise the fourth control knob located closest to the left side of the machine until it stops.• Ensure the Gas Safety Shutoff Valve (Fig. 1) on top of the machine is in the open position, allowing gas to flow into the Water Tower (Fig.1).• On the back side of the machine, open the Internal Dryer Drain Valve (Fig. 2). Drain into a small container or bucket. Pour the drained liquid into the Reservoir Tank as needed (see “Adding Water”). Ensure the Internal Dryer Valve (Fig. 2) is back in the closed position after draining.• Ensure the Fill Cap for the Reservoir Tank (Fig. 2) is installed and fully tightened.• On the right side of the machine, towards the front, find the External Water Trap (Fig. 4). Unscrew the cap and add distilled water, preferably Watt-Ahh® , to the outside fill line or until the water level is approximately 3.5” measured from the bottom of the tank (approximately 8 oz.). Re-install and tighten the cap of the External Water Trap (Fig 4).

Page 3: WATER ION 10 Cell Machine...Reservoir Level Indicator of the Reservoir Tank located on the right hand side of the 10-Cell Machine. Ensure the water level is above the minimum fill

SECTION 2: Unit Pre-Startup Checklist Continued• On the top of the machine, remove the cap of the clear Water Tower (Fig. 1). Fill the Water Tower (Fig. 1) with approximately one liter (33.9 oz.) of distilled water, preferably Watt-Ahh® to the fill line located outside the Water Tower. (Note: the water in the Water Tower needs to be replaced after each day of use and may be used to refill Reservoir Tank (see “Adding Water”). Replace the cap of the Water Tower (Fig. 1) and ensure that it is secure. • Check all exterior tubing for kinks and free and clear of anything that could crush or pinch the tubing.• Pre-startup is now complete. Refer to “Unit Startup” for instructions on beginning the operation of the machine.

Unit Startup• Plug the unit into the appropriate power source (see “Unit Specifications”).• On the front of the machine turn ON the Main Power Switch (Fig. 3) and ensure the Green Indicator Light (Fig. 3) is illuminated.• On the right side of the machine, check the Reservoir Level Indicator (Fig. 4). If it is at or below the minimum fill line, unscrew the Reservoir Fill Cap (Fig. 1) on top of the machine and add the necessary amount of distilled water, preferably Watt-Ahh® , needed (while the pump is running), filling the level indicator about half way between the minimum and maximum fill lines (refer to “Adding Water” for further instructions). Please note, while the unit is running the level inside the tank will be lower than when the unit is turned off. • Watch for the blue Indicator Light (Fig. 3) to come on, indicating the system is ready for operation.• On the Power Supply (Fig. 3), slowly rotate clockwise the left knob or also labeled as “coarse” knob on the current side of the Power Supply clockwise until the display reads approximately 40 (+/- 1.0).• Watch the System Pressure Gauge on the front of the machine carefully. • It should remain constant near 5 psi. If the pressure rises above 20 psi, the machine will shut down automatically for your safety.• In the event that the machine shuts down, please call 303.355.9696 for technical assistance before attempting to operate the machine again.

Unit Operation• At least twice during each continuous 8-hour period of operation, check the

Reservoir Level Indicator of the Reservoir Tank located on the right hand side of the 10-Cell Machine. Ensure the water level is above the minimum fill line. If the water level is near or below the minimum fill line, follow the “Unit Shutdown Procedure” to turn off the machine. Refer to “Adding Water” for instructions on adding water to the Reservoir Tank.

• As the machine is operating, check the System Pressure Gauge (Fig. 3) at the front of the machine. It should read approximately 5 psi during operation.

Unit Shutdown• Slowly rotate counterclockwise the left knob or “coarse” knob on the current

side of the Power Supply (Fig. 3) completely to the stop position (until the left display reads 0 amps and less than 5 volts on the right display).

• Turn OFF the Main Power Switch (Fig. 3) on the front of the machine.

• Open the Purge Valve at the bottom of the External Water Trap (Fig. 4). Drain the tank into a container. Pour the liquid back into the

Reservoir Tank as needed (see “Adding Water”).• Empty the Water Tower (Fig. 1) into the reservoir tank as needed. Clean the

machine tank with a damp paper towel thoroughly before the next use.

Safety Shutdown• This machine is equipped with an automated Safety Shutoff System. • The automated controls system monitors three critical factors during the machine operation: reactor pressure, water level and External Water Trap (Fig. 4) fluid level. The system will shut off power to the machine if any of the measured factors fall outside of the intended operating parameters. Additionally, the Safety Shutoff System will not allow the Power Supply (Fig. 3) turn on unless the machine is operating within the intended operating parameters.• If the display on the Power Supply (Fig. 3) goes dark, and you have not intentionally shut down the system, it means that the safety system has shut down the machine. If this happens perform the Unit Shutdown, Unit Pre-startup, and Unit Startup procedures to reboot the system. If the machine continues to shut down or behave abnormally, please call 303.355.9696 for technical assistance.

(Fig. 2)

(Fig. 3)

(Fig. 4)

Page 4: WATER ION 10 Cell Machine...Reservoir Level Indicator of the Reservoir Tank located on the right hand side of the 10-Cell Machine. Ensure the water level is above the minimum fill

Unit Maintenance

Important Unit Operation and Safety Information

• All new units are setup for a scheduled maintenance. Please call 303.355.9696 for any repairs, transport of the machine or technical questions. Only an authorized dealer can transport the unit. Please contact an authorized factory representative for further inquiries.

• Please store the unit a on dry and flat surface and in a clean environment. For the Water Tower compartment, please ensure a dust-free environment by covering it with a vinyl sheet or putting it in a clean container.

Storage: Ambient temperature, with fluid: 50o - 100oF

Unit Specifications

• Weight: 410 lbs.• Dimensions (housing only): 36”H, 30”W, 18”D• Electrical Requirements: 120V/20A 60Hz• Power Wattage: 1800 Watt• Gas Flow Rate: 0.8 – 1.5 GPM• Gas Pressure: 0 – 15 PSI • Tubing Temperature rating: - 40o to 175oF

3800 Xanthia Street, Denver, CO 80238 | 303.355.9696 | rkmi.com

Adding Water• Perform the Unit Shutdown procedure.• Ensure that the unit is still plugged in, turn the machine back ON

so the pump is running.• On top of the machine, loosen the Reservoir Fill Cap (Fig. 1).• Pull off the Reservoir Fill Cap with the chain and magnet attached.• Wipe all accumulated particles off of the magnet.• Add distilled water, preferably Watt-Ahh® if available

(aquanew.com), until the water level reaches the maximum fill line on the side of the machine (Fig. 4). Please note, while the unit is running the level inside the tank will be lower than when the unit is turned off.

• Insert the magnet and chain back into the reservoir tank, allowing it to hang freely in the tank.

• Replace and tighten the Reservoir Fill Cap (Fig. 1).

wateriontechnologies.com

For technical assistance, please call 303.355.9696.

Nothing in this Operator’s Guide is intended to diagnose, treat, cure, or prevent any disease. For all health concerns, please consult with an appropriate licensed healthcare practitioner.