Wall MountedL/M/P/311 Series

TM-FT-0415-BTECHNICAL MANUALDownloaded from www.Manualslib.com manuals search engine

Page 2: Wall Mounted L/M/P/311 Series

1. Model Name .......................................................................................................... 2 2. Features ................................................................................................................. 4

3. Specifications ........................................................................................................ 5 4. ApplicationInformation ........................................................................................ 13 OperatingRange ....................................................................................... 13 Controllers ................................................................................................ 13

5. Installations .......................................................................................................... 18

6.WiringDiagrams .................................................................................................. 33

7. Servicing&Maintenance .................................................................................... 38

8. Troubleshooting ................................................................................................... 40

9. DimensionalData ................................................................................................ 41

10.ExplodedView&PartList ................................................................................... 47

Note:Installationandmaintenancearetobeperformedonlybyqualifiedpersonnelwhoare familiarwithlocalcodesandregulations,andexperiencedwiththistypeofequipment.

Caution:Sharpedgesandcoilsurfacesareapotentialinjuryhazard.Avoidcontactwiththem.

Warning:Movingmachineryandelectricalpowerhazard.Maycauseseverepersonnel injuryordeath.Disconnectandlockoffpowerbeforeservicingequipment.

TableofContents

Downloaded from www.Manualslib.com manuals search engine

Page 3: Wall Mounted L/M/P/311 Series

2

TM-F

T-04

15-B

1. Model Name

Controller

L/I : Wireless ControllerM/J : Wired Controller

Power Supply

Series

L : L SeriesM : M SeriesP : P Series

Type of Air-Conditioner

FT : Wall Mounted

Capacity Index

10 : Based on Btu/hr

Refrigerant

Blank : R22N : R410A

L10 V1 LFT

V1 : Single Phase, 220-240V, 50Hz

Indoor

Downloaded from www.Manualslib.com manuals search engine

Page 4: Wall Mounted L/M/P/311 Series

3

TM-F

T-04

15-B

Power Supply

Series

C : C SeriesF : F Series

Type of Air-Conditioner

R : Single Split Condensing Unit

Capacity Index

18 : Based on Btu/hr

Refrigerant

Blank : R22N : R410A

C18 V1R

V1 : Single Phase, 220-240V, 50Hz

Outdoor

Downloaded from www.Manualslib.com manuals search engine

Page 5: Wall Mounted L/M/P/311 Series

4

TM-F

T-04

15-B

2. Features

Indoor Air QualityDaikin Cooling King M-series has Plasma Generator which it is an Indoor Air Quality (IAQ) solutiontoeffectivelykillthebacteriabydamagingmicrobialDNAandsurfacestructureswithoutbeing harmfultohumantissues.Furthermore,balancingtheionizationinyourhometocombattheillfeelings associatedwithourstressfullifestylesandcreatestherefreshingenvironmentresemblingthenature.

Stylish Flat-PanelIdealblendof styleand function.Regular cleaning iseasierby justwiping theflat frontpanel.This ensurestheair-conditionerwillalwayslookbrandnewallthetime.

Wireless Remote Controller• ThecompactLCDtransmitterisabletooperatetheairconditionerunitwithinthedistanceof8meters.• Fanspeedcanbesetathigh/medium/low/superloworautomatic.• Sleep mode auto control will gradually increase or decrease the setting temperature to provide acomfortablesurroundingforsleeping.

• Airflowdirectioncanbecontrolledautomatically.• Roomtemperatureiscontrolledbyelectronicthermostat.• TherealtimetimerallowstheairconditionertobeswitchedOnandOffautomaticallybasedonusersettings.• Turbomodefunctionisavailabletoenablestherequiredsettemperaturetobeachievedinashorttime.

Auto Random RestartAutorandomrestartfunctionallowstheunittoautomaticrestartasthelastsettingconditionwhenthepowersupplyisresumedafterpowerfailure.

Self DiagnosisThemicroprocessorprovidesthepossibilitytodetectanddiagnoseanyfaultormalfunctionthatoccursinthesystem.TheerrorwillbereflectedbytheblinkingoftheLEDlights.

Built in Starter (BIS)OfferingsuperiortechnologyapprovedbyJBE,Daikinairconditionerincorporateanaccuratethermaloverloadprotectortopreventoverloadingormissadjustment.

3333

High Efficiency Heat ExchangerThe compact design of the 3-fold structure heat exchanger provides a large surface for better and more efficient heat exchange.The unique Hydrophilic slit fin has greatly improved the air flow and contact surfaces with the air, thusboosting the cooling capacity

Hydrophilic Slit F

in

Slit Fin

Plain Fin

Hea

t Tra

nsfe

r Effi

cien

cy

10%

15%

Rotary CompressorTheeverpopularrotarycompressorismoreenergyefficientandhasahigheroutputtoweightratio.

Space SavingNospaceisrequiredoneitherfloororceiling.Thisnewlydevelopedsuperslimdesignforwallmountingmaximizesfloorspaceusageandenhancesceilingappearancewhereceilingsarelow.

Downloaded from www.Manualslib.com manuals search engine

Page 6: Wall Mounted L/M/P/311 Series

5

TM-F

T-04

15-B

3.Specifications

Specifications (R22)FT10LV1LFT10MV1IFT10LV1MFT10MV1J

R09CV1

FT15LV1LFT15MV1IFT15LV1MFT15MV1J

R15CV1

FT20LV1LFT20MV1IFT20LV1MFT20MV1J

R18CV1

FT20LV1LFT20MV1IFT20LV1MFT20MV1J

R20CV1

WIRELESS

WIRED

Btu/hr 10000 13000W 2931

0.8238100.7

W 980 1220A 4.38 5.36

V/Ph/HzBtu/hr/W 10.20 10.66

l/s / CFM

l/s / CFM

161 / 342 168 / 355169 / 358 176 / 372

l/s / CFM 133 / 282 141 / 298

l/s / CFM 106 / 22599 / 209

114 / 242106 / 225

dBA 39 / 38 / 33 / 27 / 25 41 / 40 / 35 / 29 / 28

mm/in 288 / 11.3288 / 11.3

mm/in800 / 31.5800 / 31.5

mm/in206 / 8.1216 / 8.5

mm/in 344 / 13.5

mm/in 874 / 34.4mm/in 274 / 10.8

kg/lb

-

-YES

YES9 / 19.8

mm/in 19 / 0.75

CONTROLAIR DISCHARGE

220-240 / 1 / 50

AUTO LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)

R22OUTDOOR CAP. TUBE

IND

OO

R U

NIT

SOUND PRESSURE LEVEL (T/H/M/L/Q)

AIR FLOW

HIGH TURBO

MEDIUM

UNITDIMENSION

HEIGHTL SERIESM SERIESL SERIES

L SERIESM SERIES

M SERIES

L SERIES

L SERIESM SERIES

M SERIES

WIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)

UNIT NET WEIGHT

OTHERFEATURES

PLASMA

NEGATIVE ION

MODEL

OUTDOOR UNIT

LOWl/s / CFMQUIET

INDOOR UNIT

NOMINAL CAPACITY

SENSIBLE HEAT FACTORNOMINAL TOTAL INPUT POWER

OPERATION

POWER SOURCE

REFRIGERANT TYPEEER

WIDTH

PACKINGDIMENSION

NOMINAL RUNNING CURRENT

REFRIGERANT CONTROL (EXPANSION DEVICE)

DEPTH

HEIGHT

WIDTHDEPTH

CONDENSATE DRAIN SIZE

195005715

18508.12

180005275

0.700.7316307.16

11.04

280 / 594251 / 531

224 / 474199 / 422180 / 381

44 / 42 / 39 / 36 / 35310 / 12.2310 / 12.2

1065 / 41.91065 / 41.9

224 / 8.8233 / 9.2

386 / 15.2

1136 / 44.7314 / 12.4

14 / 30.8

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

10.54

mm/inmm/in

FAN

TYPE CROSS FLOW FANQUANTITY 1MATERIAL GLASS REINFORCED ACRYL STYRENE RESINDRIVE DIRECTDIAMETER 92 / 3.6LENGTH 607 / 23.9

FAN MOTOR

TYPE INDUCTIONQUANTITY 1INDEX OF PROTECTION (IP) IP24

POWER SOURCERATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT

INSULATION GRADE

POLES

SPEED RPM

V/Ph/HzWAW

TURBOHIGHMEDIUMLOWSILENT

CLASS E220 - 240 / 1 / 50

37

128012301050880830

132012701100930880

400.2018

4

IP44

102 / 4.02867 / 34.13

610.3026

11301050960875800

mm/inmm/in

mm/inm²/ft²

COIL

TUBEMATERIAL SEAMLESS INNER GROOVE COPPERDIAMETER 7.00 / 0.276THICKNESS 0.28 / 0.011

FIN

MATERIAL ALUMINIUMTHICKNESS 0.11 / 0.0043FACE AREA 0.18 / 1.94ROW 2FIN PER INCH 18

0.24 / 0.00945

0.105 / 0.00410.29 / 3.12

pcLENGTH mm/inWIDTH mm/inTHICKNESS mm/in

MATERIAL

AIRQUALITY

FILTER

TYPE

302 / 11.9280 / 11.0

2.0 / 0.1CASING PLASTIC

QUANTITY

SIZE 306 / 12.1

SARANET2

421 / 16.5

kg/lb 0.60 / 1.3 0.60 / 1.3REFRIGERANT CHARGE 0.90 / 1.98 0.83 / 1.83

Downloaded from www.Manualslib.com manuals search engine

Page 7: Wall Mounted L/M/P/311 Series

6

TM-F

T-04

15-B

Specifications (R22) - Continued

MODEL INDOOR UNITWIRELESS

WIRED

OUTDOOR UNITl/s / CFM 321 / 680 453 / 960

dBA 45 49

mm/in 497 / 19.6 543 / 21.4mm/in 600 / 23.6 700 / 27.6mm/in 245 / 9.6 250 / 9.8mm/in 535 / 21 596 / 23.51mm/in 721 / 28.4 803 / 31.6mm/in 330 / 13 323 / 12.7kg/lb 25 / 55 28 / 61.7

LIQUID mm/in 6.35 / 1/4GAS mm/in 9.52 / 3/8 12.7 / 1/2

FLARE VALVE

UNITDIMENSION

HEIGHT

WIDTH

OU

TD

OO

R U

NIT

UNIT NET WEIGHT

PIPECONNECTION

TYPE

SIZE

WIDTHPACKINGDIMENSION

DEPTH

DEPTH

HEIGHT

AIR FLOW

SOUND PRESSURE LEVEL

614 / 1300

5152

654 / 25.7855 / 33.7328 / 12.9693 / 27.3990 / 39.0415 / 16.343 / 94.8

15.88 / 5/8

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

mm/in

cm²/fl.oz

QUANTITY

355 / 14.0 401 / 15.8DIAMETERINDUCTION

QUANTITY 1

1PROPELLER

MATERIAL ASG20DRIVE DIRECT

FAN

TYPE

COMPRESSOR

TYPE ROTARY

FAN MOTOR

TYPE

OIL AMOUNTOIL TYPE SUNISO-4GSI / FREOL-K56

330 / 11 350 / 11.8

32 740.17 0.3318 30

6

751

860SPEED RPM

V/Ph/HzWAW

POWER SOURCERATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT

INSULATION GRADE

POLES

220 - 240 / 1 / 50B F

CLASS EPOWER SOURCECAPACITORRATED INPUT POWER

RATED RUNNING CURRENT LOCKED ROTOR AMP.

INSULATION GRADEV/Ph/Hz

µF

WAA

30.0 30.0

911 11064.01 4.8317.5 25

220 - 240 / 1 / 50

600 / 20.3600 / 20.3

455 / 17.9

IP23

770.34328

680

770.34326

40

14926.52

36

35

1712

7.4841

INDEX OF PROTECTION (IP)

m²/ft²

mm/in 7.00 / 0.276mm/in

mm/in 0.11 / 0.004

0.29 / 3.14 0.35 / 3.82

118 20 20

MATERIAL

ALUMINIUMTHICKNESS

FIN

MATERIALCOIL

TUBEMATERIAL SEAMLESS INNER GROOVE COPPERDIAMETER

THICKNESS

FACE AREA

ROWFIN PER INCH

CASING GALVANISED STEEL

0.51 / 5.47

0.23 / 0.009

FT10LV1LFT10MV1IFT10LV1MFT10MV1J

R09CV1

FT15LV1LFT15MV1IFT15LV1MFT15MV1J

R15CV1

FT20LV1LFT20MV1IFT20LV1MFT20MV1J

R18CV1

FT20LV1LFT20MV1IFT20LV1MFT20MV1J

R20CV1

Downloaded from www.Manualslib.com manuals search engine

Page 8: Wall Mounted L/M/P/311 Series

7

TM-F

T-04

15-B

Specifications (R22)FT25LV1LFT25MV1IFT25LV1MFT25MV1J

R25CV1Btu/hr 24000

W 7034

W 2675A

0.71

12.0V/Ph/HzBtu/hr/W 8.97

l/s / CFMl/s / CFM

290 / 614303 / 641

l/s / CFM 253 / 537l/s / CFMl/s / CFM

224 / 474197 / 418

dBA 48 / 46 / 43 / 40 / 37

mm/in 310 / 12.2310 / 12.2

mm/in1065 / 41.91065 / 41.9

mm/in 224 / 8.8233 / 9.2

mm/in 386 / 15.2mm/in 1136 / 44.7mm/in 314 / 12.4

--

--

YES

YESkg/lb 14 / 30.8

mm/in 19 / 0.75

NOMINAL RUNNING CURRENT

REFRIGERANT CONTROL (EXPANSION DEVICE)

WIDTH

PACKINGDIMENSION

OTHERFEATURES

CONDENSATE DRAIN SIZE

DEPTH

HEIGHTWIDTHDEPTH

PLASMA

NEGATIVE ION

REFRIGERANT TYPEEER

WIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)

UNIT NET WEIGHT

MODEL

OUTDOOR UNIT

LOWQUIET

INDOOR UNITWIRELESS

WIRED

NOMINAL CAPACITY

SENSIBLE HEAT FACTORNOMINAL TOTAL INPUT POWER

OPERATION

POWER SOURCE

CONTROLAIR DISCHARGE

IND

OO

R U

NIT

SOUND PRESSURE LEVEL (T/H/M/L/Q)

AIR FLOWHIGH TURBO

MEDIUM

UNITDIMENSION

HEIGHT L SERIESM SERIESL SERIESM SERIESL SERIES

L SERIES

L SERIES

M SERIES

M SERIES

M SERIES

220-240 / 1 / 50

AUTO LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)

R22OUTDOOR CAP. TUBE

mm/inmm/in

FANMOTOR

QUANTITYMATERIALDRIVE

TYPE

FAN

QUANTITYINDEX OF PROTECTION (IP) IP44

CROSS FLOW FAN

DIAMETERLENGTHTYPE

1

DIRECTGLASS REINFORCED ACRYL STYRENE RESIN

102 / 4.02867 / 34.13

INDUCTION1

CLASS EIP24

CLASS B220-240 / 1 / 50POWER SOURCE

RATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT

INSULATION GRADE

POLES

SPEED RPM

TURBOHIGHMEDIUMLOWSILENT

V/Ph/HzWAW

1280123511101010930

-130012001080

-

4

720.3430

mm/inmm/in

mm/inm²/ft²

COIL

FIN

TUBE

ROWFIN PER INCH

DIAMETERTHICKNESS

THICKNESSFACE AREA

MATERIAL

MATERIAL SEAMLESS INNER GROOVE COPPER7.00 / 0.276

0.24 / 0.00945ALUMINIUM

0.105 / 0.00410.29 / 3.12

218

pcLENGTH mm/inWIDTH mm/inTHICKNESS mm/in

AIRQUALITY

FILTERSIZE

QUANTITYTYPE

306 / 12.12.0 / 0.1

SARANET2

421 / 16.5

MATERIALCASING PLASTIC

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

kg/lb 1.15 / 2.53REFRIGERANT CHARGE

FT311V1L

FT311V1M

R31CV128,00082100.70315013.1

8.89

1.85 / 4.08

316 / 670-

-

297 / 630236 / 500

49 / 47 / 45

360 / 14.2

1200 / 47.2

200 / 7.9

420 / 16.51267 / 49.9260 / 10.2

17 / 37.4820 / 0.79

106 / 4.17950 / 37.4

700.340

9.52 / 0.3750.35 / 0.013

0.11 / 0.00430.291 / 3.130

3330 / 13.0317 / 12.41.8 / 0.07

Downloaded from www.Manualslib.com manuals search engine

Page 9: Wall Mounted L/M/P/311 Series

8

TM-F

T-04

15-B

Specifications (R22) - Continued

mm/in

cm³/ fl.oz. 700 / 24.6

INDOOR UNIT

WIRELESS

WIRED

OUTDOOR UNIT

MODEL

FAN MATERIAL

DRIVE

TYPE

QUANTITY

DIAMETER

COMPRESSOR

TYPE

OIL TYPE

INDEX OF PROTECTION (IP)

FAN MOTOR

OIL AMOUNT

DIRECT

457 / 18.0

PROPELLER

QUANTITY

TYPE

ASG20

455 / 17.9

ATMOS NM56M or SUNISO 4GDID

1

INDUCTION

1

IP23 IP54

ROTARY

V/Ph/Hz

W

A

W

POWER SOURCE

RATED INPUT POWER

RATED RUNNING CURRENT

MOTOR OUTPUT

INSULATION GRADE

POLES

SPEED RPM

220 - 240 / 1 / 50

CLASS F CLASS B

121

0.53

874840

60

6

POWER SOURCE

CAPACITOR

RATED INPUT POWER

RATED RUNNING CURRENT

LOCKED ROTOR AMP.

INSULATION GRADE

V/Ph/Hz

µF

W

A

A

45

2482

11.13

56

CLASS E

220 - 240 / 1 / 50

m²/ft²

mm/in

mm/in

ALUMINIUM

mm/in

0.61 / 6.58

1

20

2

18

MATERIAL

MATERIAL

MATERIAL

ROW

FIN PER INCH

DIAMETER

THICKNESS

THICKNESS

FACE AREA

CASING

COIL

FIN

TUBE 7.00 / 0.276

SEAMLESS INNER GROOVE COPPER

GALVANISED STEEL

0.23 / 0.009

0.11 / 0.0043

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

OU

TD

OO

R U

NIT

l/s / CFM 755 / 1600

dBA 52

mm/in 756 / 29.8

mm/in 855 / 33.7

mm/in 328 / 12.9

mm/in 793 / 31.2

mm/in 990 / 39.0

mm/in 415 / 16.3

kg/lb 50 / 110.2

LIQUID mm/in 9.52 / 3/8

GAS mm/in 15.88 / 5/8

WIDTH

HEIGHT

AIR FLOW

SOUND PRESSURE LEVEL

HEIGHTPACKINGDIMENSION

DEPTH

DEPTH

UNIT NET WEIGHT

PIPECONNECTION

TYPE

SIZE

WIDTH

UNITDIMENSION

FLARE VALVE

808 / 1712

56

756 / 29.8

855 / 33.7

328 / 12.9

793 / 31.2

990 / 39.0

415 / 16.3

57 / 126

GLASS REINFORCED ACRYL STYRENE RESIN

139

0.6

75

900 / 31.70

50

2941

12.2

72

0.62 / 6.63

FT25LV1L

FT25MV1I

FT25LV1M

FT25MV1J

R25CV1

FT311V1L

FT311V1M

R31CV1

Downloaded from www.Manualslib.com manuals search engine

Page 10: Wall Mounted L/M/P/311 Series

9

TM-F

T-04

15-B

Specifications (R410A)FTN10PV1LFTN10MV1I9FTN10PV1MFTN10MV1J9

RN10FV1

FTN15PV1LFTN15MV1I9FTN15PV1MFTN15MV1J9

RN15FV1

FTN20PV1LFTN20MV1I9FTN20PV1MFTN20MV1J9

RN20CV1

FTN25PV1LFTN25MV1I9FTN25PV1MFTN25MV1J9

RN25CV1Btu/hr 9500 12000 18000 22000

W 2784 3517 5275 64480.82 0.75 0.76 0.75

W 870 1105 1835 2060A 3.86 4.94 8.10 9.14

V/Ph/HzBtu/hr/W 10.92 10.86 9.81 10.68

l/s / CFM 169 / 358 176 / 372 280 / 594 303 / 641l/s / CFM 161 / 342 168 / 355 251 / 531 290 / 614l/s / CFM 133 / 282 140 / 298 224 / 474 253 / 537l/s / CFM 106 / 225 114 / 242 199 / 422 224 / 474l/s / CFM 99 / 209 106 / 225 180 / 381 197 / 418

dBA 39/ 38/ 33/ 27/ 25 41/ 40/ 35/ 29/ 28 44/ 42/ 39/ 36/ 35 48/ 46/ 43/ 40/ 37

mm/inmm/inmm/in

mm/in

kg/lb 0.75 / 1.65 0.88 / 1.94 1.00 / 2.20 1.70 / 3.75REFRIGERANT CHARGE

P-SERIESM-SERIESP-SERIESM-SERIES

-YES

-

OTHERFEATURES

PLASMA

288 / 11.3

800 / 31.5

212 / 8.3DEPTHM-SERIES

YES

310 / 12.2

1065 / 41.9

228 / 9.0

P-SERIESM-SERIES

mm/in

P-SERIES mm/in

kg/lbUNIT NET WEIGHTCONDENSATE DRAIN SIZE

AIR FLOW

TURBO

PACKINGDIMENSION

HEIGHTWIDTHDEPTH

P-SERIESHEIGHTM-SERIES

WIDTH

INDO

OR

UNIT

CONTROL AIR DISCHARGEOPERATION

HIGH MEDIUMLOW

SOUND PRESSURE LEVEL (T/H/M/L/Q)

UNITDIMENSION

NEGATIVEION

MODEL

OUTDOOR UNIT

NOMINAL CAPACITY

NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT

INDOOR UNITWIRELSS

WIRED

220 - 240 / 1 / 50

R410AOUTDOOR CAP TUBE

SENSIBLE HEAT FACTOR

LOUVER UP & DOWNWIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)

POWER SOURCEEERREFRIGERANT TYPEREFRIGERANT CONTROL (EXPANSION DEVICE)

QUIET

216 / 8.5 233 / 9.2

mm/in

344 / 13.5 386 / 15.2874 / 34.4 1136 / 44.7274 / 10.8 314 / 12.4

9 / 19.8 14 / 30.819.05 / 0.75

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

mm/ inmm/ in

V / Ph / HzW 37 42 61 72A 0.19

128012301050880830

132012701100930880

11301050960875800

1280123511101010930

0.21 0.30 0.34W 26 30

FANMOTOR

TYPEQUANTITYINDEX OF PROTECTION (IP)INSULATION GRADEPOWER SOURCERATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT POLES

SPEED

FAN

TYPEQUANTITYMATERIALDRIVE

LENGTHDIAMETER

CROSS FLOW

DIRECT

1 PHASE SCR

1ASG30

92 / 3.62 102 / 4.02

E

184

607 / 23.9 867 / 34.13

120

230 / 1 / 50

mm / in

RPM

mm / in

mm/ in

FIN PER INCH

COIL

TUBEMATERIAL

TURBOHIGHMEDIUMLOWQUIET

DIAMETERTHICKNESS

FIN

MATERIALTHICKNESSFACE AREAROW

18

COPPER7.00 / 0.276

ALUMINIUM

0.18 / 1.93 0.29 / 3.122

0.1 / 0.0039

0.2 / 0.0079

m² / ft²

pcmm / in mm / in mm / in

FILTER

TYPEQUANTITY

SIZELENGTHWIDTHTHICKNESS

302 / 11.89AIRQUALITY

SARANET2

421 / 16.57280 / 11.02 306 / 12.05

2 / 0.08 2 / 0.08MATERIALCASING PLASTIC

Downloaded from www.Manualslib.com manuals search engine

Page 11: Wall Mounted L/M/P/311 Series

10

TM-F

T-04

15-B

Specifications (R410A) - Continued

mm/ in

B B F F

V / Ph / Hz

W 50

0.22

51 78 121

A

930

0.23

920

0.34 0.53

W

RPM

20 32

710

61

840

cm³ / fl. Oz. 330 320 670

V / Ph / Hz

µF 35 50

W 783 1012 1696 1867

A 3.45 4.50 7.46 8.27

A 18.0 24.50 32 32

mm / in 7 / 0.28

mm / in 0.2 / 0.0079

mm / in

m² / ft² 0.33 / 3.55 0.32 / 3.44 0.51 / 5.49 0.50 / 5.38

1 2 1 2

18 18 20 18

MATERIALCASING

ROW

FIN PER INCH

COIL

TUBE

MATERIAL

DIAMETER

THICKNESS

FIN

MATERIAL

THICKNESS

FACE AREA

COMPRESSOR

TYPE

OIL TYPE

OIL AMOUNT

INSULATION GRADE

POWER SOURCE

LOCKED ROTOR AMP.

RATED INPUT POWER

RATED RUNNING CURRENT

FANMOTOR

TYPE

QUANTITY

INDEX OF PROTECTION (IP)

INSULATION GRADE

POWER SOURCE

RATED INPUT POWER

RATED RUNNING CURRENT

MOTOR OUTPUT

POLESSPEED

FAN

OU

TD

OO

R U

NIT

TYPE

QUANTITY

MATERIAL

DRIVE

DIAMETER

MODEL

OUTDOOR UNIT

INDOOR UNIT

WIRELESS

WIRED

CAPACITOR

PROPELLER

DIRECT

INDUCTION370 / 14.6 455 / 17.9

0.1 / 0.0039

GALVANISE STEEL

COPPER

ALUMINIUM

6

ROTARY

FV50SNMOC Ze-Gles RB68EPHAF68D1

1

ASG 20

1

23

230 / 1 / 50

E

220-240/1/50

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

l/s / CFM 438 / 927 390/ 827 675 / 1430 755 / 1600

dBA 46 48 49 52

mm/in 654 / 25.7

mm/in 855 / 33.7

mm/in 328 / 12.9

mm/in 693 / 27.3

mm/in 990 / 39.0

mm/in 415 / 16.3

kg/lb 28 / 61.7 29 / 63.9 43 / 94.8 47 / 103.6

mm/in

mm/in 9.52 / 3/8 12.7 / 1/2 12.7 / 1/2 15.88 / 5/8

HEIGHT

WIDTH

DEPTH

UNIT NET WEIGHT

PIPECONNECTION

TYPE

SIZELIQUID

GAS

AIR FLOW

SOUND PRESSURE LEVEL

UNITDIMENSION

HEIGHT

WIDTH

DEPTH

PACKINGDIMENSION

550 / 21.7

658 / 25.9

273 / 10.7

580 / 22.8

775 / 30.5

355 / 14.0

FLARE

6.35 / 1/4

FTN10PV1L

FTN10MV1I9

FTN10PV1M

FTN10MV1J9

RN10FV1

FTN15PV1L

FTN15MV1I9

FTN15PV1M

FTN15MV1J9

RN15FV1

FTN20PV1L

FTN20MV1I9

FTN20PV1M

FTN20MV1J9

RN20CV1

FTN25PV1L

FTN25MV1I9

FTN25PV1M

FTN25MV1J9

RN25CV1

Downloaded from www.Manualslib.com manuals search engine

Page 12: Wall Mounted L/M/P/311 Series

11

TM-F

T-04

15-B

Specifications (R410A)FTN311V1L

FTN311V1M

RN28CV1

Btu/hr 26,000

W 7620

0.69

W 2560

A 12.20

V/Ph/Hz 220 - 240 / 1 / 50

Btu/hr/W 10.16

R410A

OUTDOOR CAP. TUBE

AUTO LOUVER (UP& DOWN) & GRILLE (LEFT & RIGHT)

WIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)

l/s / CFM 316 / 670

l/s / CFM 297 / 630

l/s / CFM 236 / 500

dBA 49 / 47 / 45

mm/in 360 / 14.2

mm/in 1200 / 47.2

mm/in 200 / 7.9

mm/in 420 / 16.5

mm/in 1267 / 49.9

mm/in 260 / 10.2

kg/lb 17 / 37.48

mm/in 20 / 0.79

kg/lb 1.80 / 3.97

MODELINDOOR UNIT

WIRELESS

WIRED

OUTDOOR UNIT

NOMINAL CAPACITY

SENSIBLE HEAT FACTOR

NOMINAL TOTAL INPUT POWER

NOMINAL RUNNING CURRENT

POWER SOURCE

EER

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNITDIMENSION

HEIGHT

WIDTH

DEPTH

PACKINGDIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

REFRIGERANT CHARGE

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

CROSS FLOW FAN

1

ACRYLO NITRILE STYRENE

DIRECT

mm/ in 106 / 4.17

mm/ in 950 / 37.4

INDUCTION

1

IP24

CLASS B

V / Ph / Hz 220 - 240 / 1 / 50

W 71

A 0.3

W

RPM

40

4130012001080

DIAMETER

MOTOR OUTPUT

FAN

TYPE

QUANTITY

MATERIAL

DRIVE

LENGTH

FAN MOTOR

TYPE

QUANTITY

INDEX OF PROTECTION (IP)

INSULATION GRADE

POWER SOURCE

RATED INPUT POWER

RATED RUNNING CURRENT

POLES

SPEED

SEAMLESS INNER GROOVE COPPER

mm / in 7.0 / 0.276

mm / in 0.28 / 0.011

ALUMINIUM

mm/ in 0.11 / 0.0043

0.30 / 3.23

2

18

MATERIAL

THICKNESS

FACE AREA

ROW

COIL

TUBE

MATERIAL

HIGHMEDIUM

LOW

DIAMETER

THICKNESS

FIN

FIN PER INCH

m² / ft²

SARANETpc 3

mm / in 330 / 13.0mm / in 317 / 12.4mm / in 1.8 / 0.07

SIZELENGTHWIDTHTHICKNESS

AIR QUALITY FILTER

TYPEQUANTITY

MATERIAL PLASTICCASING

Downloaded from www.Manualslib.com manuals search engine

Page 13: Wall Mounted L/M/P/311 Series

12

TM-F

T-04

15-B

Specifications (R410A) - Continued

PROPELLER

1

ASG20

DIRECT

455 / 17.9

INDUCTION

1

IP23

CLASS F

V / Ph / Hz 220 -240 / 1 / 50

W 124

A 0.54

W

RPM

66

874

6

SCROLL

FV50S

cm³ / fl. Oz. 1130 / 38

CLASS E

V / Ph / Hz 220 -240 / 1 / 50

µF 45.0

W 2365

A 11.36

A 63

COPPER

mm / in 7 / 0.28

mm / in 0.23 / 0.009

ALUMINIUM

mm / in 0.11 / 0.0043

m² / ft² 0.61 / 6.58

2

18

MATERIAL GALVANISED STEEL

MODELWIRELESS

INDOOR UNITWIRED

OUTDOOR UNIT

DIAMETER

RATED INPUT POWER

RATED RUNNING CURRENT

MOTOR OUTPUT

POLES

SPEED

FAN

TYPE

QUANTITY

MATERIAL

DRIVE

CAPACITOR

RATED INPUT POWER

RATED RUNNING CURRENT

LOCKED ROTOR AMP.

FAN MOTOR

TYPE

QUANTITY

INDEX OF PROTECTION (IP)

INSULATION GRADE

POWER SOURCE

COMPRESSOR

TYPE

OIL TYPE

OIL AMOUNT

INSULATION GRADE

POWER SOURCE

FIN

MATERIAL

THICKNESS

FACE AREA

COIL

TUBE

MATERIAL

DIAMETER

THICKNESS

CASING

ROW

FIN PER INCH

1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.

OU

TD

OO

R U

NIT

l/s / CFM 808 / 1712

dBA 54

mm/in 756 / 29.8

mm/in 855 / 33.7

mm/in 328 / 12.9

mm/in 793 / 31.2

mm/in 990 / 39.0

mm/in 416 / 16.4

kg/lb 57 / 25.6

FLARE VALVE

mm/in 9.52 / 3/8

mm/in 15.88 / 5/8

AIR FLOW

SOUND PRESSURE LEVEL

UNITDIMENSION

HEIGHT

WIDTH

DEPTH

PACKINGDIMENSION

HEIGHT

WIDTH

DEPTH

UNIT NET WEIGHT

PIPE CONNECTION

TYPE

SIZELIQUID

GAS

FTN311V1L

FTN311V1M

RN28CV1

Downloaded from www.Manualslib.com manuals search engine

Page 14: Wall Mounted L/M/P/311 Series

13

TM-F

T-04

15-B

4.ApplicationInformation

Operating Range

Ensure the operating temperature is in allowable range.

Caution :The use of your air conditioneroutside the range of workingtemperature and humidity canresult in serious failure.

Cooling

DB: Dry bulb WB: Wet bulb

OU

TDO

OR

TEM

P. D

B (˚

C)

INDOOR TEMP. WB (˚C)

50

464340

30

20

10

010 14 15 19 20 23 25

Controller

DGS01

Operating Guide

1 Transmission Source • The source where the signal will be transmitted.

2 Signal Transmission Indication • Blink to confirm that the last setting has been transmitted to the unit.

3 “ON/OFF” Button • Press once to start the air conditioner unit. • Press again to stop the unit.

4 Fan speed selection • Press the button continuously will toggle the fan speed in the following order: Low � Med � High � Auto • Stop pressing when the desired fan speed appears on the display screen.

5 Operation mode • Press the MODE button to select the type of operating mode. • For cooling only unit, the available modes are: COOL ( ), DRY ( ) and FAN ( ).

6 Automatic air swing • Press the SWING ( ) button to activate the automatic air swing function. • To distribute the air to a specific direction, press the SWING ( ) button andwait until the louver move to the desired direction and press the button once again.

7 Turbo function • Press for fast cooling operation. • Fan speed turn to maximum speed. • Press again to deactivate the function. • Available under COOL and DRY modes only. • Any change of fan speed will deactivate this function.

TURBO QUIET

SLEEP

ON OFF

MODE

TIMER

CANCEL CANCELCLOCK

3

13

4

9

12

7

1

2

5

6

8

10

11

Downloaded from www.Manualslib.com manuals search engine

Page 15: Wall Mounted L/M/P/311 Series

14

TM-F

T-04

15-B

4 Fan speed selection • Press the button continuously will toggle the fan speed in the following order: Low → Med → High → Auto • Stop pressing when the desired fan speed appears on the display screen.

5 Operation mode • Press the MODE button to select the type of operating mode. • For cooling only unit, the available modes are: COOL ( ), DRY ( ) and FAN ( ).

6 Automatic air swing • Press the SWING ( ) button to activate the automatic air swing function. • To distribute the air to a specific direction, press the SWING ( ) button and wait until the louver move to the desired direction and press the button once again.

7 Turbo function • Press for fast cooling operation. • Fan speed turn to maximum speed. • Press again to deactivate the function. • Available under COOL and DRY modes only. • Any change of fan speed will deactivate this function.

8 Quiet function • Press for quiet operation. • Fan speed turn to minimum speed. • Press again to deactivate the function. • Any change of fan speed will deactivate this function.

9 ON timer setting • Press the ON TIMER button will activate the on timer function. • Set the desired on time by pressing the ON TIMER button continuously. If the timer is set to 7.30am, the air conditioner will turn on at 7.30am sharp. • Press the CANCEL button to cancel the on timer setting.

10 OFF timer setting • Press the OFF TIMER button will activate the off timer function. • Set the desired off time by pressing the OFF TIMER button continuously. • Press the CANCEL button to cancel the off timer setting.

11 Clock time setting • Press and hold button to set the clock time.

12 Sleep mode setting • Press the button will activate the sleep mode function. • This is an energy saving option. When the unit is operating under cooling mode, the set temperature is increased by 0.5°C after 30 minutes, 1˚C after an hour, and 2˚C after 2 hours. • This function is available under COOL mode.

13 Temperature setting • To set the desired room temperature, press the or button to increase or decrease the set temperature. • The temperature setting range is from 16°C to 30°C. • Press both buttons and simultaneously to toggle from °C to °F setting.

Downloaded from www.Manualslib.com manuals search engine

Page 16: Wall Mounted L/M/P/311 Series

15

TM-F

T-04

15-B

DSLM8

Operating Guide

MODETURBO

TIMEROVERRIDE

TIMER

ON OFFTIMER

SWING QUIET

SLEEP

14

5

6

23

1011

8

97

1 MODE Button Press the MODE button to switch operation from COOL, AUTO*, DRY*, FAN. Check the display to

see in which mode the control is set. *AUTO and DRY are available for selected models only.

2 TURBO Fan Speed Press the Turbo key once to activate Turbo fan speed. Turbo symbol will be shown. To disable Turbo

fan speed and back to previous fan speed, press the Turbo key once again. For the unit that does not have TURBO fan speed it will show high fan speed.

3 SWING Function Press SWING button to activate the swing function. Press it again to deactivate it.

4 QUIET Fan Speed Press the Quiet key once to activate Quiet fan speed. Quiet symbol will be shown. To disable Quiet

fan speed and back to previous fan speed, press the Quiet key once again. For the unit that does not have QUIET fan speed it will show low fan speed.

5 “�” or “�” Set Temperature Button Press the temperature button and set the temperature of your choice by pressing “�” or “�” button

once, temperature changes by 1°C or 1°F. The default temperature setting range is from 16°C to 30°C (60°F to 86°F). When the Option 20 - 30ºC is set, the temperature range limit is set to 20ºC to 30ºC (68°F to 86°F). Pressing both keys simultaneously will toggle the temperature setting between ºC and ºF.

6 SLEEP Function Press the SLEEP button to activate the sleep mode. DRY MODE and FAN MODE are not valid

during sleep function.

Downloaded from www.Manualslib.com manuals search engine

Page 17: Wall Mounted L/M/P/311 Series

16

TM-F

T-04

15-B

7 “ON TIMER” and “OFF TIMER” The unit has 2-event timer, namely Timer 1 and Timer 2, each event has an ON TIMER and an OFF

TIMER. The key press activity for Timer ON and Timer OFF is shown on Table 1.1

Table 1.1: Timer ON and Timer OFF key press and event sequence.

All timers are event-triggered timers and can be overridden by the ON/OFF button and Override function.

Set Event 1 and Event 2 Timers

Process for Timer ON and Timer OFF is the same.1. Press and hold Timer ON/OFF key for 3 seconds to go into timer setting mode. (Icon ON 1 or OFF 1 will blink)2. Press UP or DOWN to select Timer 1 or Timer 2 to set. (‘1’ blinking indicate that Timer 1 is currently selected, ‘2’ blinking indicate that Timer 2 is currently selected)3. Press Timer ON/OFF key again to confirm. (Day will blink next)4. Press UP or DOWN to select the day.5. Press Timer ON/OFF key again to confirm the day. (Hour will blink next)4. Press UP or DOWN to change the hour.5. Press Timer ON/OFF key again to confirm the hour. (Minute will blink next)6. Press UP or DOWN to change the minute.7. Press Timer ON/OFF key again to confirm the minute.

Each timer (Timer 1 ON or Timer 1 OFF or Timer 2 ON or Timer 2 OFF) will only be set separately after all 7 steps, if there is no key operation for 5 seconds during setting the timer, it will automatically exits from setting mode and no changes will be made.

ON/OFF timer will be checked every 1 minute.It is not advisable to set ON TIMER and OFF TIMER to have same values. Shall these occur, the effective timer will be treated with priority as stated in Table 1.2.Example:ON TMR 2 settings: DAY – TUE, TIMER – 5.00pmOFF TMR 1 settings: DAY – TUE, TIMER – 5.00pmOutcome when RTC reaches 5.00pm on TUE: - when unit is on, no respond. - when unit is off, unit will trigger to on.

Table 1.2: Timer Priority

ON Timer 1 ON Timer 2 OFF Timer 1 OFF Timer 2 Deactivated Deactivated Deactivated Deactivated Activated Deactivated Activated Deactivated Deactivated Activated Deactivated Activated Activated Activated Activated Activated

TIMER ON KEY TIMER OFF KEY

Priority Timer1 (Highest)

23

4 (Lowest)

ONTMR2OFFTMR2ONTMR1OFFTMR1

Upon IR reception, IR wireless remote controller will override ON TIMER 2 and OFF TIMER 2 settings.

Downloaded from www.Manualslib.com manuals search engine

Page 18: Wall Mounted L/M/P/311 Series

17

TM-F

T-04

15-B

8 OVERRIDE Function Press the OVERRIDE key once will activate the override function for 1 hour. An indicator

“OVERRIDE 1” will show on the LCD. Press the same key again will increase the setting to 2 hours. An indicator “OVERRIDE 2” will be shown. Subsequent press will deactivate the override function. After the override timer is completed, the override function is deactivated and the logo is OFF. All other timers will be resumed.

9 FAN Speed Function Fan speed can be changed via pressing the FAN key: Low > Med > High > Auto > Low >

10 ON/OFF Button Starting Operation: - Press the ON/OFF button, the LCD will show full display and the unit is turned on. Stopping Operation: - Press the ON/OFF button, the LCD will show real time clock only and the unit is turn off.

11 Real-time Clock (RTC) Display RTC is shown on screen during the unit ON or OFF except for power failure or error code.

Set RTC Setting 1. Press RTC key one time will activate RTC setting mode. (Day will blink) 2. Press UP or DOWN to select the day. 3. Press RTC again to confi rm the day. (Hour will blink next) 4. Press UP or DOWN to change the hour. 5. Press RTC again to confi rm the hour. (Minute will blink next) 6. Press UP or DOWN to change the minute. 7. Press RTC again to confi rm the minute. RTC will only be set after all 7 steps, if there is no key operation for 5 seconds during setting the

RTC, it will automatically exits from setting mode and no changes will be made on the setting.

12 Hardware Setting The unit has 4 jumpers option to control the board function. Table 2.0: Summary of Hardware Settings

OPTION

Set Temp. Range

TURBO_QUIET

Reserved

Reserved

With Jumper

Set Temp. Range from 20˚C-30˚C

Reserved

Reserved

Without Jumper

Set Temp. Range from 16˚C-30˚C(Default)

Enable turbo and quiet fan speed

Reserved

Reserved

Disable turbo and quiet fan speed(Default)

Wired Remote Control (Universal Board)Cooling

Error Code at 7 Segment Display Operation / Faulty Indication Blink E1 Room sensor contact open / short Blink E2 Indoor coil sensor contact open Blink E3 Outdoor coil sensor contact open

Blink E4 Compressor overload/ Indoor coil sensor short/Outdoor coil sensor short

Blink E5 Gas leak Blink E6 Pump faulty

Downloaded from www.Manualslib.com manuals search engine

Page 19: Wall Mounted L/M/P/311 Series

18

TM-F

T-04

15-B

5.Installations

Installation GuidelineSafety Precautions

WARNING

CAUTIONPlease take note of the following important points when installing.

If gas leaks and accumulates around the unit, it may cause fire ignition.

Ensure that drainage piping is connected properly.If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture.

Do not overcharge the unit.

This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor.

Ensure that the unit’s panel is closed after service or installation.

Unsecured panels will cause the unit to operate noisily.

Sharp edges and coil surfaces are potential locations which may cause injury hazards.Avoid from being in contact with these places. Before turning off the power supply, set the remote controller’s ON/OFF switch to the “OFF” positionto prevent the nuisance tripping of the unit. If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user. Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic panel to melt or deform as a result of the excessive heat. Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively.

IMPORTANT : DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM.Do not use joined and twisted wires for incoming power supply.

Do not install the unit where leakage of flammable gas may occur. •

••

NOTICE

• Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance.• All field wiring must be installed in accordance with the national wiring regulation.• Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.• The unit must be GROUNDED to prevent possible hazard due to insulation failure.• All electrical wiring must not touch the refrigerant piping or any moving parts of the fan motors.• Confirm that the unit has been switched OFF before installing or servicing the unit.• Disconnect from the main power supply before servicing the air conditioner unit.• DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in fire hazards.• Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. {Depending on the type and source of the electrical waves, static may be heard even when more than 1m away}.

Disposal requirementsYour air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste.Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information.Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.

Downloaded from www.Manualslib.com manuals search engine

Page 20: Wall Mounted L/M/P/311 Series

19

TM-F

T-04

15-B

Installation Diagram

Caution• Before installing the unit, ensure that the power supply matches the power requirement of the air conditioner.

Installation Of The Outdoor Unit

Installation Clearances

The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or obstruction to the smooth air flow. Please follow the installation clearances shown in the figure. Select the coolest possible place where intake air temperature is not greater than the outside air temperature (please refer operating range).

Note: If there is any obstacle higher than 2m, or if there is any obstruction at the upper part of the unit, please allow more space than the figure indicated in the above table.

Front panel

50mm or more from walls (on both sides)

75mm or more from ceiling

M4 x 12LAir filter

Service lid■ Opening service lid Service lid is opening/

closing type.■ Opening method dil ecivres eht evomeR )1

screws. dil ecivres eht tuo lluP )2

diagonally down in the direction of the arrow.

3) Pull down.

500mm from wall

Indoor unit

Outdoor unit

Caulk pipe hole gap with putty.

Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe’s cut line.

Wrap the insulation pipe with the finishing tape from bottom to top.

Ret

urn

air

Dis

char

ge a

ir

A

Obs

tacl

e

Obs

tacl

e

B

Obs

tacl

e

Ret

urn

air

Ser

vice

acc

ess

DC

Obs

tacl

e

Dimension A B C D

Minimum Distance, mm (in)

300(11.8)

1000(39.4)

300(11.8)

500(19.7)

Downloaded from www.Manualslib.com manuals search engine

Page 21: Wall Mounted L/M/P/311 Series

20

TM-F

T-04

15-B

Air flow (Indoor)

min

. 75

(Spa

ce fo

r pe

rfor

man

ce)

Required space

All dimensions are in mm

min. 50

(Space for maintenance)

min. 50

(Space for maintenance)

Right-Side, Right-Back or Right-Bottom Piping

Right-back piping

Bind coolant pipe and drain hose together with insulating tape.

Right-bottom piping

Remove pipe port cover here for right-bottom piping

Right-side piping

Remove pipe port cover here for right-side piping

Remove pipe port cover here for left-bottom piping

Remove pipe port cover here for left-side piping

Left-back piping

Left-bottom piping

Left-Side, Left-Back or Left-Bottom Piping

Left-side piping

Installation Of The Indoor Unit

The indoor unit must be installed in such a way so as to prevent short circuit of the cool discharged air with the hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there could be direct sunlight shining on it. Also, this location must be suitable for piping and drainage, and be away from doors or windows.

The refrigerant piping can be routed to the unit in a number of ways (left or right from the back of the unit), by using the cut-out holes on the casing of the unit (see figure). Bend the pipes carefully to the required position in order to align it with the holes. For the side and bottom out, hold the bottom of the piping and then position it to the required direction (see figure). The condensation drain hose can be taped to the pipes.

Mounting Installation Plate

Mounting plate

Mounting platefixing screw

FT10/15LV1L/M & FT10/15MV1I/JFTN10/15PV1L/M & FTN10/15MV1I9/J9

Mounting plate

Mounting platefixing screw

FT20/25LV1L/M & FT20/25MV1I/JFTN20/25PV1L/M & FTN20/25MV1I9/J9

FT311V1L/M & FTN311V1L/M

Installation plate

Marking-offline

Thread

Ensure that the wall is strong enough to withstand the weight of the unit. Otherwise, it is necessary to reinforce the wall with plates, beams or pillars. Use the level gauge for horizontal mounting, fix it with 5 suitable screws for FT10/15LV1L/M, FTN10/15PV1L/M & FT10/15MV1I/J, FTN10/15MV1I9/J9 and 7 suitable screws for FT20/25LV1L/M, FTN20/25PV1L/M & FT20/25MV1I/J, FTN20/25MV1I9/J9 and 4 suitable screws for FT311V1L/M & FTN311V1L/M. In case the rear piping draws out, drill a hole 65mm in diameter with a cone drill, slightly lower on the outside wall (see figure).

Downloaded from www.Manualslib.com manuals search engine

Page 22: Wall Mounted L/M/P/311 Series

21

TM-F

T-04

15-B

Recommended Mounting Plate Retention Spots And Dimensions

Through the wallhole Ø 65mm

Recommended mounting plate retention spots (5 spots in all)

Use tape measure as shown.Position the end of a tape measureat166 184

42.2

288

42.2

Drain hosepositionGas pipe endLiquid pipe end

181.7 55.554.5 153.8 263 51.9800

45.9

45.9

All dimensions are in mm

FT10/15LV1L/M & FT10/15MV1I/JFTN10/15PV1L/M & FTN10/15MV1I9/J9

FT20/25LV1L/M, FT20/25MV1I/JFTN20/25PV1L/M & FTN20/25MV1I9/J9

All dimensions are in mm

Inside Outside

Hole with cone drill

CaulkingWall embedded pipe (Field supply)

Wall hole cover (Field supply)

Wall embedded pipe (Field supply)

Ø 65

Mounting plate

Interconnectingwires

Hang indoor unit’s hook here.

Wire guide

When stripping the ends of interconnecting wires in advance, bind right ends of wires with insulating tape.

Mounting plate

Clip

Mark (rear side)

Bottom frameFront grille

End dipped into water

Water leaking

Water leaking

Water leaking

Wrong Wrong Wrong

Drain

Water Drainage

Water retention

Correct

CAUTION• Do not install the unit at altitude over 2000m

for both indoor and outdoor.

Mount The Unit Onto The Installation PlateHook the indoor unit onto the upper portion of the installation plate (Engage the two hooks at the rear top of the indoor unit with the upper edge of the installation plate). Ensure that the hooks are properly seated on the installation plate by moving it to the left and right.

How To Attach The Indoor UnitHook the claws of the bottom frame to the mounting plate.

How To Remove The Indoor UnitPush up the marked area (at the lower part of the front grille) to release the claws.

Water Drainage PipingThe indoor drain pipe must be in a downward gradient for smooth drainage. Avoid situations that are likely to cause water to leak.

Recommended mounting plate retention spots (7 spots in all)

190 173

6131

0

61

Gas pipe endLiquid pipe end 4845580 1065

219

40 40

9145

Through the wall hole Ø 65mm

Drain hoseposition

Downloaded from www.Manualslib.com manuals search engine

Page 23: Wall Mounted L/M/P/311 Series

22

TM-F

T-04

15-B

Outdoor Unit L E

Indoor Unit

Refrigerant PipingPiping Length & ElevationIf the pipe is too long, both the capacity and reliability of the unit will drop. As the number of bends increases, resistance to the flow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective. Always choose the shortest path and follow the recommendations as tabulated below:

ModelIndoor FT10LV1L/M

FT10MV1I/JR09CV1

FT15LV1L/MFT15MV1I/J

R15CV1

FT25LV1L/MFT25MV1I/J

R25CV1

FT311V1L/MFT20LV1L/MFT20MV1I/J

3

20

12 15 25

37

5

9.50 (3/8”)

6.35 (1/4”) 6.35 (1/4”) 9.50 (3/8”)

12.70 (1/2”) 15.88 (5/8”)

8

OutdoorMin. Allowable Length (L), m

Max. Allowable Length (L), m

Additional Charge of Refrigerant (g/m)

Max. Allowable Elevation (E), m

Gas Pipe Size, mm / (in)

Liquid Pipe Size, mm / (in)

Example: FT10LV1L & R09CV1 with 12m piping length, additional piping length is 4.5m. Thus,Additional charge = 4.5m x [20g/m] = 90 [g]* Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Remark: The refrigerant pre-charged in the outdoor unit is for piping length up to 7.5m.

For R410A :

For R22:

Indoor Unit FTN10PV1L/MFTN10MV1I9/J9

RN10FV1

FTN15PV1L/MFTN15MV1I9/J9

RN15FV1

FTN20PV1L/MFTN20MV1I9/J9

RN20CV1

FTN25PV1L/MFTN25MV1I9/J9

RN25CV1

FTN311V1L/M

RN28CV1Outdoor Unit

25338

9.50 (3/8")9.50 (3/8")

Model

Liquid Pipe Size, mm / (in)

15

33020

12.70 (1/2")

6.35 ( 1/4")

15.88 (5/8")

2518Additional Charge of Refrigerant (g/m)

Min. Allowable Length (L),m

Gas Pipe Size, mm / (in)Max. Allowable Elevation (E), m

Max. Allowable Length (L), m

R18CV1 R20CV1 R31CV1

Downloaded from www.Manualslib.com manuals search engine

Page 24: Wall Mounted L/M/P/311 Series

23

TM-F

T-04

15-B

Remove burr

Cutting copper tube

1/4t

Flared tubeFlare joint

Flare nutIndoor piping

Torque wrenchSpanar

Ø Tube, D A (mm)Inch mm Imperial

(Wing-nut Type)Rigid

(Clutch Type)1/4" 6.35 1.3 0.73/8" 9.52 1.6 1.01/2" 12.70 1.9 1.35/8" 15.88 2.2 1.73/4" 19.05 2.5 2.0

Pipe Size (mm/in)

Torque (Nm/ft-lb)

6.35 (1/4") 18 (13.3)9.52 (3/8") 42 (31.0)12.70 (1/2") 55 (40.6)15.88 (5/8") 65 (48.0)19.05 (3/4") 78 (57.6)

Figure D

Figure A

Copper tubeSwaging block A

D

Figure B

Figure C

Piping Works And Flaring Technique• Do not use contaminated or damaged copper

tubing. If any piping, evaporator or condenser had been exposed or had been opened for 15 seconds or more, the system must be vacuumed. Generally do not remove plastic, rubber plugs and brass nuts from the valves, fittings, tubing and coils until it is ready to connect suction or liquid line into valves or fittings.

• If any brazing work is required, ensure that nitrogen gas is passed through coil and joints while the brazing work is being done. This will eliminate soot formation on the inside wall of copper tubings.

• Cut the pipe stages by stages, advancing the blade of pipe cutter slowly. Extra force and a deep cut will cause more distortion of pipe and therefore extra burr. See Figure A.

• Remove burrs from cut edges of the pipes with remover. See Figure B. Hold the pipe on top position and burr remover at lower position to prevent metal chips from entering the pipe. This will avoid unevenness on the flare faces which will cause gas leak.

• Insert the flare nuts, mounted on the connection parts of both the indoor unit and outdoor unit, into the copper pipes.

• The exact length of pipe protruding from the top surface of the swaging block is determined by the flaring tool. See Figure C.

• Fix the pipe firmly on the swaging block. Match the centers of both the swaging block and the flaring punch, then tighten the flaring punch fully.

Piping Connection To The Units• Align the center of the piping and tighten the

flare nut sufficiently with fingers. See Figure D.• Finally, tighten the flare nut with torque wrench

until the wrench clicks.• When tightening the flare nut with the torque

wrench, ensure that the tightening direction follows the arrow indicated on the wrench.

• The refrigerant pipe connection are insulated by closed cell polyurethane.

Downloaded from www.Manualslib.com manuals search engine

Page 25: Wall Mounted L/M/P/311 Series

24

TM-F

T-04

15-B

ModelFT311V1L/R31CV1FT311V1M/R31CV1

FTN311V1L/RN28CV1FTN311V1M/RN28CV1

Voltage range** 220-240V/1Ph/50Hz +

Power supply cable size* mm²Number of conductors

43

Interconnection cable size* mm²Number of conductors

Recommended time delay fuse A

2.54

25

!

FT311V1L

FT311V1M

R31CV1Outdoor

Indoor

Voltage range** 220-240V/1Ph/50Hz +

Power supply cable size* mm²Number of conductors

Interconnection cable size* mm²Number of conductors

Recommended time delay fuse A

2.53

2.53

20

FTN311V1L

FTN311V1M

RN28CV1Outdoor

IndoorModel

There must be an all pole disconnection in the supply mains with a contact separation of at least 3mm.

!There must be an all pole disconnection in the supply mains with a contact separation of at least 3mm.

COMP

N2

N1

L

COMP

N

COMP

N2

N1

LCOMP

R

S

N

L

N

L

Outdoor UnitTerminal Block

Power Supply Cable

Power Supply Cable

Indoor UnitTerminal Block

Outdoor UnitTerminal Block

Indoor UnitTerminal Block

Cooling Unit (single phase)

Model

Voltage range** 220-240V/1Ph/50Hz +

Power supply cable size* mm²Number of conductors

2.53

Interconnection cable size* mm²Number of conductors

Recommended time delay fuse A

2.53

20

1.53

1.53

15

FT10/15LV1L

FT10/15LV1M

FT10/15MV1I

FT10/15MV1J

FTN10/15PV1L

FTN10/15PV1M

FTN10/15MV1I9

FTN10/15MV1J9

FT20/25LV1L

FT20/25LV1M

FT20/25MV1I

FT20/25MV1J

FTN20/25PV1L

FTN20/25PV1M

FTN20/25MV1I9

FTN20/25MV1J9

Outdoor

COMP COMP

NN1

N

L

Indoor UnitTerminal Block Interconnection Cable

Outdoor UnitTerminal Block

Power Supply Cable Main Switch

N / L2

L/L1PowerSupply

Fuse / CircuitBreaker

!There must be an all poledisconnection in the supplymains with a contactseparation of at least 3mm.

Indoor

R09/15CV1RN10/15FV1

R18/20/25CV1RN20/25CV1

Downloaded from www.Manualslib.com manuals search engine

Page 26: Wall Mounted L/M/P/311 Series

25

TM-F

T-04

15-B

Attach insulation sleeve

Round crimp-style terminalElectric wire

Connect wires of the same gauge to both side.

Do not connect wires of the same gauge to one side.

Do not connect wires of different gauges.

• All wires must be firmly connected.• Make sure all the wire do not touch the refrigerant piping, compressor or any moving parts.• The connecting wire between the indoor unit and the outdoor unit must be clamped by using

provided cord anchorage.• The power supply cord must be equivalent to H07RN-F which is the minimum requirement.• Make sure no external pressure is applied to the terminal connectors and wires.• Make sure all the covers are properly fixed to avoid any gap.• Use round crimp-style terminal for connecting wires to the power supply terminal block. Connect the

wires by matching to the indication on terminal block. (Refer to the wiring diagram attached on the unit).

• Used the correct screwdriver for terminal screws tightening. Unsuitable screwdrivers can damage the screw head.

• Over tightening can damage the terminal screws.• Do not connect wire of different gauge to same terminal.• Keep wiring in an orderly manner. Prevent the wiring from obstructing other parts and the terminal

box cover.

Downloaded from www.Manualslib.com manuals search engine

Page 27: Wall Mounted L/M/P/311 Series

26

TM-F

T-04

15-B

Vacuuming is necessary to eliminate all moisture and air from the system.

Refrigerant Piping

Outdoor Unit 3 ways valve

Allen key

Service Port

Flare nut

HIGH PRESSURE GAUGE

GAUGE MANIFOLD

LOW PRESSURE GAUGE

HANDLE HI (ALWAYS CLOSED)

CHARGE HOSE

-760mmHg

HANDLE LO

CHARGE HOSE VACUUM PUMP ADAPTER FOR

COUNTER FLOW PREVENTION

CHECK

VALVE

LIQUID

VALVE

HIGH PRESSURE GAUGELOW PRESSURE GAUGE

GAUGE MANIFOLD-760mmHg

HANDLE LO HANDLE HI (ALWAYS CLOSED)

CHARGE HOSECHARGE HOSE

CHECK

VALVE

LIQUID

VALVEGAS VALVE

(3-WAY)

CONFIGURATION OF AIR PURGE BY CHARGING

GAS VALVE (3-WAY)

CONFIGURATION OF AIR PURGE BY CHARGING

Vacuuming And Charging

Vacuuming The Piping And The Indoor UnitExcept for the outdoor unit which is pre-charged with refrigerant, the indoor unit and the refriger-ant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle may cause malfunction of the compressor.• Remove the caps from the valve and the

service port.• Connect the center of the charging gauge to

the vacuum pump.• Connect the charging gauge to the service port

of the 2-way valve.• Start the vacuum pump. Evacuate for approxi-

mately 30 minuted. The evacuation time varies with different vacuum pump capacity. Confirm that the charging gauge needle has moved towards - 760mmHg.

Caution• If the gauge needle does not move to

-760mmHg, be sure to check for gas leaks (using the refrigerant detector) at fl are type connection of the indoor and outdoor unit and repair the leak before proceeding to the next step.

• Close the valve of the changing gauge and stop the vacuum pump.

• On the outdoor unit, open the suction valve (3 way) and liquid valve (2 way) (in anti-clockwise

direction) with 4mm key for hexagon sacked screw.

Charge OperationThis operation must be done by using a gas cylinder and a precise weighing machine. The additional charge is topped-up into the outdoor unit using the suction valve via the service port.

• Remove the service port cap.• Connect the low pressure side of the charging

gauge to the suction service port center of the cylinder tank and close the high pressure side of the gauge. Purge the air from the service hose.

• Start the air conditioner unit.

• Open the gas cylinder and low pressure charging valve.

• When the required refrigerant quantity is pumped into the unit, close the low pressure side and the gas cylinder valve.

• Disconnect the service hose from service port. Put back the service port cap.

Downloaded from www.Manualslib.com manuals search engine

Page 28: Wall Mounted L/M/P/311 Series

27

TM-F

T-04

15-B

FT L/M, FTN P/M

Indicator Lights

ON to OFF 1 Long BeepOFF to ON 2 Short Beep Pump down/Cool force onOthers 1 Short Beep

IR Receiver

LED Indicator Lights for Cooling Unit

IR Receiver

ON/OFF

CoolTimerSleepON/OFF switch

IR Signal ReceiverWhen an infrared remote control operating signal has been transmitted, the signal receiver on the indoor unit will respond as below to confirm acceptance of the signal transmission.

Cooling UnitThe table shows the LED indicator lights for the air conditioner unit under normal operation and fault conditions. The LED indicator lights are located at the right-bottom of the air conditioner unit.

Downloaded from www.Manualslib.com manuals search engine

Page 29: Wall Mounted L/M/P/311 Series

28

TM-F

T-04

15-B

Normal Operation /noitacidnI tluaF

––Cool Mode

Auto mode in Cooling operation

––Timer on

––no edom peelS

––no edom naF

––no edom yrD

Room air sensor contact

Loose / ShortCall your dealer Blink E1

Outdoor coil sensor open Call your dealer Blink E3

Indoor coil sensor open Call your dealer Blink E2

Compressor overload /

Indoor coil sensor short / Call your dealer Blink E4

outdoor coil sensor short

––noitarepo tsorfeD

5E knilBrelaed ruoy llaCkael saG

Hardware error (tact switch pin short) Call your dealer Blink E8

No feedback from indoor fan Call your dealer Blink E9

1 time

COOL(GREEN)

Green

Red

1 time

3 times

3 times

4 times

2 times

6 times

Green

ON ON or OFF Blinking

LED Indicator Lights : Normal Operation And Fault Conditions For CoolingUnit

ErrorCode

Action

– –

Downloaded from www.Manualslib.com manuals search engine

Page 30: Wall Mounted L/M/P/311 Series

29

TM-F

T-04

15-B

LED Indicator Lights : Normal Operation And Fault Conditions

Operation / Fault Indication Action

Timer on

Sleep mode on

Dry mode on

Frost prevention

Sensor contact problem, compressor overloadprotection trip or gas leak

Indoor coil sensor contact loose / short

Room air sensor contact loose / short Call your dealer

Clean the filter and switch to high fan

-

-

-

- ON / - ON or OFF - Blinking

LED Indicator Lights

Power Dry Timer Sleep

/Continuously

once every 2 sec.

twice every 2 sec.

3 times every 2 sec.

Call your dealer

Call your dealer

FT311/FTN311

Downloaded from www.Manualslib.com manuals search engine

Page 31: Wall Mounted L/M/P/311 Series

30

TM-F

T-04

15-B

Air Conditioner Unit Operation

In COOL, DRY and FAN mode

When stopoperation

Upper limit 55˚

Lower limit 85˚

Dry Mode• When the air humidity is high, the unit can operate in dry mode. Press <MODE> button and choose <DRY>.• If the room temperature is 2°C/3.6°F higher than the set temperature, the air conditioner will operate

under cooling mode until it reaches within the 2°C/3.6°F range of difference compared to the set temperature before it converts to dry mode.

• If the room temperature is within the 2°C/3.6°F range of difference compared to the set temperature, it will directly operate under dry mode.

• The unit will operate at LOW speed under dry mode.

Air Flow Control• For more effective air circulation, you can manually adjust the air discharge grille to the left or right.• During cool mode operation and dry mode operation, do not direct the air discharge louver down-

wards for too long. If operating continues in this way, condensation may occur on the louver, thus resulting indrippings.

Frost Prevention• When the air filter is dirty, the evaporating temperature will decrease and eventually cause frosting.• If the evaporating temperature reaches -1°C/33.8°F, the unit will trip.

Fan Speed And Rated Cooling Capacity• The rated cooling capacity is provided at the high fan speed.• The cooling capacity is lower when the unit is operating at MEDIUM and LOW fan speed.

Notes On Flaps And Louvers Angles• When “SWING button” is selected, the flaps swinging range depends on the operation mode. (See the figure.)

ATTENTION• Always use a remote controller to adjust the flaps angle. If you attempt to move it forcibly with hand

when it is swinging, the mechanism may be broken.• Be careful when adjusting the louvers. Inside the air outlet, a fan is rotating at a high speed.

Auto Random Re-start FunctionIf there is a power cut when the unit is operating, it will automatically resume the same operating mode when the power is restored.

Downloaded from www.Manualslib.com manuals search engine

Page 32: Wall Mounted L/M/P/311 Series

31

TM-F

T-04

15-B

Special Precautions When Dealing With Refrigerant R410A Unit

(1) What is New Refrigerant R410A?R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential.

(2) ComponentsMixture weight composition R32(50%) and R125(50%)

(3) Characteristic• R410A liquid and vapour components have different compositions when the fluid

evaporates of condenses. Hence, when leak occurs and only vapor leaks out, the composition of the refrigerang mixture left in the system will change and subsequently affect the system performance. DO NOT add new refrigerant to leaked system. It is recommended that the system should be evacuated thoroughly before recharging with R410A.

• When refrigerant R410A is used, the composition will differ depending on whether it is in gaseous or liquid phase. Hence when charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is to make certain that only original composition of R410A is being charged into the system.

• PVE oil is used as lubricant for R410A compressor, which is different from the mineral oil used for R22 compressor. Extra precaution must be taken not to expose the R410A system too long to moist air.

(4) Check List Before Installation / Servicing• Tubing

Refrigerant R410A is more easily affected by dust of moisture compared with R22, make sure to temporarily cover the ends of the tubing prior to installation.

• Compressor oilNo additional charge of compressor oil is permitted.

• RefrigerantNo other refrigerant other that R410A

• Tools (size of service port is different from R22 system)Tools specifically for R410A only (must not be used for R22 or other refrigerant)i) Gauge manifold and charging hoseii) Gas leak detectoriii) Refrigerant cylinder/charging cylinderiv) Vacuum pump c/w adapterv) Flare toolsvi) Refrigerant recovery machine

(5) Handling and Installation GuildelinesLike R22 system, the handling and installation of R410A system are closely similar. All precautionary measures; such as ensuring no moisture, no dirt or chips in the system, clean brazing using nitrogen, and thorough leak check and vacuuming are equally important requirements.However, due to it hydroscopic PVE oil, additional precautions must be taken to ensure optimum and trouble free system operation.

(a) During installation or servicing, avoid prolong exposure of the internal part of the refrigerant system to moist air. Residual PVE oil in the piping and components can absorb moisture from the air.

(b) Ensure that the compressor is not exposed to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal plugs only when the compressor is about to be brazed.

(c) The system should be thoroughly vacuumed to 1.0 Pa (700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system.

Downloaded from www.Manualslib.com manuals search engine

Page 33: Wall Mounted L/M/P/311 Series

32

TM-F

T-04

15-B

(d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This isto ensure that only the original composition of R410A is being delivered into the system. The liquid composition can be different from the vapour composition.

(e) Normally, the R410A cylinder or can is being equipped with a dip pipe for liquid withdrawal. However, if the dip pipe is not available, invert the cylinder or can so as to withdraw liquid from the valve at the bottom.

Downloaded from www.Manualslib.com manuals search engine

Page 34: Wall Mounted L/M/P/311 Series

33

TM-F

T-04

15-B

6.WiringDiagrams

Indoor UnitModel : FT10/15LV1L, FT10/15LV1M FTN10/15PV1L, FTN10/15PV1M

Outdoor UnitModel : R09/15CV1 RN10/15FV1

WHITE WHITE

Downloaded from www.Manualslib.com manuals search engine

Page 35: Wall Mounted L/M/P/311 Series

34

TM-F

T-04

15-B

WHITE

Indoor UnitModel : FT20/25LV1L, FT20/25LV1M FTN20/25PV1L, FTN20/25PV1M

Outdoor UnitModel : R18/20/25CV1, RN20/25CV1

Downloaded from www.Manualslib.com manuals search engine

Page 36: Wall Mounted L/M/P/311 Series

35

TM-F

T-04

15-B

Indoor UnitModel : FT10/15MV1I, FT10/15MV1J FTN10/15MV1I9, FTN10/15MV1J9

Outdoor UnitModel : R09/15CV1 RN10/15FV1

WHITE WHITE

Downloaded from www.Manualslib.com manuals search engine

Page 37: Wall Mounted L/M/P/311 Series

36

TM-F

T-04

15-B

WHITE

Indoor UnitModel : FT20/25MV1I, FT20/25MV1J FTN20/25MV1I9, FTN20/25MV1J9

Outdoor UnitModel : R18/20/25CV1 RN20/25CV1

Downloaded from www.Manualslib.com manuals search engine

Page 38: Wall Mounted L/M/P/311 Series

37

TM-F

T-04

15-B

Outdoor UnitModel : R31CV1, RN28CV1

Indoor UnitModel : FT311V1L, FT311V1M FTN311V1L, FTN311V1M

Downloaded from www.Manualslib.com manuals search engine

Page 39: Wall Mounted L/M/P/311 Series

38

TM-F

T-04

15-B

7.ServicingandMaintenance

Components Maintenance Procedures PeriodAir Filter

(Indoor Unit)1. Remove any dust adhering to the filter by using a vacuum cleaner

or wash in lukewarm water (below 40˚C) with a neutral cleaning detergent.

2. Rinse the filter well and dry before placing it back onto the unit.3. Note: Never use gasoline, volatile substances or chemicals to

clean the filter.

At least once every 2 weeks.More frequently if necessary.

Indoor Unit 1. Clean any dirt or dust on the grille or panel by wiping it wi th a soft cloth soaked in lukewarm water (below 40˚C) and a neutral detergent solution.

2. Note: Never use gasoline, volatile substances or chemicals to clean the indoor unit.

At least once every 2 weeks.More frequently if necessary.

Condense Drain Pan & Pipe

1. Check the cleanliness and clean it if necessary.2. Check the condensate water flow.

Every 3 months.

Indoor Fan Check if there is any abnormal noise. If necessary.Indoor / Outdoor

Coil1. Check and remove the dirt between the fins.2. Check and remove any obstacles which hinder air flow through the

indoor or outdoor.

Every month.

Power Supply 1. Check the running current and voltage for indoor and outdoor unit.2. Check the electrical wiring and tighten the wire onto the terminal

block if necessary.

Every 2 months.

Every year.

Compressor No maintenance needed if refrigerant circuit remains sealed. However, check for refrigerant leak at joint and fitting.

Every 6 months.

1. Open the front panel• Hold the panel at the recesses on the main unit

(2 recesses on right and left sides) and lift it until it stops.

2. Remove the front panel• While lifting the front panel further, slide it to the

right and pull it to the front side. The left rotating shaft is detached. Slide the right rotating shaft to the left and pull it to the front side to remove it.

3. Attach the front panel• Align the right and left rotating shafts of the front

panel with the grooves and push them all the way in.

• Gently close the front panel. (Push both ends and the center on the front panel.)

Rotatingshaft

Recess onmain unit

! CAUTION• Don’t touch the metal parts of the indoor unit. It may cause an injury.• When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.• When removing or attaching the front panel, support the panel securely with hand to prevent from it falling.• For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing

compound, scrubbing brushes, nor other hand stuff.• After cleaning, make sure that the front panel is securely fixed

Downloaded from www.Manualslib.com manuals search engine

Page 40: Wall Mounted L/M/P/311 Series

39

TM-F

T-04

15-B

Caution!

Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surface once every 3 months. However, if a unit is installed in areas subjected to much oil mist and dust, the coils must be regularly cleaned by qualified Air Conditioner Service Technicians to ensure sufficient heat exchange and proper operation. Otherwise, the systems life span may be shortened.

Do not charge OXYGEN, ACETYLENE OR OTHER FLAMMABLE and poisonous gases into the unit when performing a leakage test or an airtight test. These gases could cause severe explosion and damage if exposed to high temperature and pressure.It is recommended that only nitrogen or refrigerant be charged when performing the leakage or airtight test.

Pre Start Up Maintenance(After Extended Shutdown)

• Inspect thoroughly and clean indoor and outdoor units.• Clean or replace air filters.• Clean condensates drainline.• Clean clogged indoor and outdoor coils.• Check fan imbalance before operation.• Tighten all wiring connections and panels.• Check for refrigerant leakage.

The design of the outdoor series allows servicing to be carried out easily. The removal of the top, front and side panels makes almost every part accessible.

Downloaded from www.Manualslib.com manuals search engine

Page 41: Wall Mounted L/M/P/311 Series

40

TM-F

T-04

15-B

8.Troubleshooting

When a malfunction of the air conditioner unit is detected, immediately switch off the main power supplybefore proceeding with the following troubleshooting procedures.The following are common fault conditions and simple troubleshooting tips. If any other fault conditions whichare not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself.

snoitca evitcerroc / sesuac elbissoP snoitidnoc tluaF oN

1 The air conditioner unit will not resume after power failure.

• The auto restart function is not functioning. Please turn on the unit with the wireless / wired controller.

2 The compressor does not operate 3 minutes after the air conditioner unit is started.

• Protection against frequent starting. • Wait for 3 or 4 minutes for the compressor to start

operating by it self.

3 The airflow is too slow or room cannot be cooled sufficiently.

• The air filter is dirty. • The doors and windows are opened. • The air suction and discharge of both indoor and

outdoor units are clogged or blocked. • The regulated temperature or temperature setting

is not low enough.

4 Discharge airflow has bad odor. • Cigarettes, smoke particles, perfume and others, which might have adhered onto the coil, may cause odor.

• Contact your nearest dealer.

5 Condensation on the front air grille of the indoor unit.

• This is caused by air humidity after an extended period of operation.

• The set temperature is too low. Increase the temperature setting and operate the unit at high fan speed.

6 Water flowing out from the air conditioner. • Switch off the unit and contact your nearest dealer. This might be due to tilted installation.

7 Hissing airflow sound from the air conditioner unit during operation.

• Liquid refrigerant flowing into the evaporator coil.

8 The wireless controller display is dim. • The batteries are discharged. • The batteries are not correctly inserted. • The assembly is not good.

9 Compressor operates continuously. • Dirty air filter. Clean the air filter. • Temperature setting too low (cooling). Use higher

temperature setting.

10 No cool air comes out during cooling cycle. • Temperature setting too high (cooling). Use lower temperature setting.

Downloaded from www.Manualslib.com manuals search engine

Page 42: Wall Mounted L/M/P/311 Series

41

TM-F

T-04

15-B

9.DimensionalData

Indoor Unit - FTL & FTM Series FTNP & FTNM Series

All dimensions are in mm

DimensionModel A B C D E F G H I J K L M

FT10/15LV1LFT10/15LV1MFTN10/15PV1LFTN10/15PV1M

800 288 166 184 42 46 55 56 154 182 263 52206

212

ATHE MARK SHOWS PIPING DIRECTION

LEFT

REAR

TOP VIEW

REAR

RIGHT

B

BOTTOM

LOUVER FRONT GRILLE FIXED SCREWS(INSIDE)

BOTTOM

FRONT VIEW

SIGNAL RECEIVER

INDOOR UNITON/OFF SWITCH

ROOM TEMPERATURE THERMISTOR (INSIDE)

B

NAME PLATE

TERMINALBLOCK WITHEARTH TERMINAL

C

SIDE VIEW

etalp gnitnuom dednemmoceR retention spots (5 spots in all)

D

Use tape measure as shown.Position the end of a tape measure at

BG

H JL M

A

K

F

I

G

F

E

Through the wallhole Ø 65mm

Drain hose position

Gas pipe endLiquid pipe end

INSTALLATION PLATE : FT10/15LV1L, FT10/15LV1M & FT10/15MV1L, FT10/15MV1J FTN10/15PV1L, FTN10/15PV1M & FTN10/15MV1I9, FTN10/15MV1J9

FT10/15MV1IFT10/15MV1JFTN10/15MV1I9FTN10/15MV1J9

800 288 216 166 184 42 46 55 56 154 182 263 52

Downloaded from www.Manualslib.com manuals search engine

Page 43: Wall Mounted L/M/P/311 Series

42

TM-F

T-04

15-B

All dimensions are in mm

DimensionModel A B C D E F G H I J K L M

FT10/15LV1LFT10/15LV1MFTN10/15PV1LFTN10/15PV1M

800 288 104 141 30 46 55 56 153 181 207 52206

212

ALTERNATIVE INSTALLATION PLATE : FT10/15LV1L, FT10/15LV1M & FT10/15MV1L, FT10/15MV1J FTN10/15PV1L, FTN10/15PV1M & FTN10/15MV1I9, FTN10/15MV1J9

stops noitneter etalp gnitnuom dednemmoceR (5 spots in all)

Through the wallhole Ø 65mm

Drain hose position

Gas pipe endLiquid pipe end

E

FG

IKML

JH

FG

B

D

A

FT10/15MV1IFT10/15MV1JFTN10/15MV1I9FTN10/15MV1J9

800 288 216 104 141 30 46 55 56 153 181 207 52

Downloaded from www.Manualslib.com manuals search engine

Page 44: Wall Mounted L/M/P/311 Series

43

TM-F

T-04

15-B

All dimensions are in mm

DimensionModel A B C D E F G H I J K L M

FT20/25LV1LFT20/25LV1MFTN20/25PV1LFTN20/25PV1M

FT20/25MV1IFT20/25MV1JFTN20/25MV1I9FTN20/25MV1J9

1065 310 190 173 61 40 45 48 91 219 580 45

1065 310 233 190 173 61 40 45 48 91 219 580 45

stopsnoitneteretalpgnitnuomdednemmoceR(7 spots in all)

D

BG

H JL M

A

K

F

I

GF

E

Through the wall hole Ø 65mm

Drain hose positionLiquid pipe end Gas pipe end

INSTALLATION PLATE: FT20/25LV1L, FT20/25LV1M & FT20/25MV1I, FT20/25MV1J FTN20/25PV1L, FTN20/25PV1M & FTN20/25MV1I9, FTN20/25MV1J9

Indoor UnitModel : FT311V1L, FT311V1M FTN311V1L, FTN311V1M

Note : Dimension in mm

200.

0

360.

0

327.

0

347.

0

224

228

Downloaded from www.Manualslib.com manuals search engine

Page 45: Wall Mounted L/M/P/311 Series

44

TM-F

T-04

15-B

All dimensions are in mm

Outdoor UnitModel: R09/15CV1

DimensionModel A B C D E F G H I J K L M N O

R09CV1 600 475 245 418 177 35 93 81 83 55 398 101 97 17 22700 521 250 485 175 36 95 93 86 68 441 130 111 15 18R15CV1

KB

LL

CN

N

M30

A

DO

319

6580

C

G H

I J

EF

Downloaded from www.Manualslib.com manuals search engine

Page 46: Wall Mounted L/M/P/311 Series

45

TM-F

T-04

15-B

All dimensions are in mm

Outdoor UnitModel: RN10/15FV1

DimensionModel A B C D E F G H I J K L M N O P

RN10/15FV1 550 658 51 11 273 16 14 470 96 299 94 60 14 133 8 8

H

NJ

GB CDE F

A

MK

L

P

O

I

Downloaded from www.Manualslib.com manuals search engine

Page 47: Wall Mounted L/M/P/311 Series

46

TM-F

T-04

15-B

All dimensions are in mm

Outdoor UnitModel: R18/20/25/31CV1 RN20/25/28CV1

DimensionModel A

855 628 328 520 179 46 93 149 101 113 603 126 164 17 34

855 730 328 533 182 44 93 149 101 113 603 126 164 17 47

B C D E F G H I J K L M N O

R18/20CV1RN20/25CV1

R18/20CV1RN20/25CV1

R25/31CV1RN28CV1

R25/31CV1RN28CV1

DimensionModel P Q R S T

32 23 73 75

32 23 73 75

3

3

A

N

B

LL

M

C

O D

N

C

HG

FE

JI

P

Q

TS

R

K

Downloaded from www.Manualslib.com manuals search engine

Page 48: Wall Mounted L/M/P/311 Series

47

TM-F

T-04

15-B

10.ExplodedView&PartList

Indoor UnitModel : FT10/15LV1L, FT10/15LV1M

NO DESCRIPTION NO DESCRIPTION

1 ASSY., FRONT GRILLEPANELAIR FILTERFRONT GRILLEASSY, CONTROL BOXASSY, SERVICE COVERASSY, PIPING FIXTUREMOTORMOTOR MOUNTING PLATE (1)MOTOR MOUNTING PLATE (2)BLOWER, CROSS FLOW

ASSY, INSTALLATION PLATERIGHT SIDE PANELDRIP PROOF COVERCLIP, COIL SENSORASSY, HEAT EXCHANGERASSY, DRAIN HOSEFAN BEARING VIBRATION ABSORBER SETASSY, DISCH, GRILLE HOR. BLADEASSY BOTTOM FRAME ASSY, PCB (WITH LAMP COVER)

12131415161718192021

23456789

1011

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Downloaded from www.Manualslib.com manuals search engine

Page 49: Wall Mounted L/M/P/311 Series

48

TM-F

T-04

15-B

Indoor UnitModel : FTN10/15PV1L, FTN10/15PV1M

NO DESCRIPTION NO DESCRIPTION

1 ASSY., FRONT GRILLEPANELAIR FILTERFRONT GRILLEASSY, CONTROL BOXASSY, SERVICE COVERASSY, PIPING FIXTUREMOTORMOTOR MOUNTING PLATE (1)MOTOR MOUNTING PLATE (2)BLOWER, CROSS FLOW

12131415161718192021

ASSY, INSTALLATION PLATERIGHT SIDE PANELDRIP PROOF COVERCLIP, COIL SENSORASSY, HEAT EXCHANGERASSY, DRAIN HOSEFAN BEARING VIBRATION ABSORBER SETASSY, DISCH, GRILLE HOR. BLADEASSY BOTTOM FRAME ASSY, PCB (WITH LAMP COVER)

23456789

1011

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Downloaded from www.Manualslib.com manuals search engine

Page 50: Wall Mounted L/M/P/311 Series

49

TM-F

T-04

15-B

Indoor UnitModel : FT10/15MV1I, FT10/15MV1J FTN10/15MV1I9, FTN10/15MV1J9

NO DESCRIPTION NO DESCRIPTION

1 ASSY., FRONT GRILLEPANELAIR FILTERFRONT GRILLEASSY, CONTROL BOXASSY, SERVICE COVERASSY, PIPING FIXTUREMOTORMOTOR MOUNTING PLATE (1)MOTOR MOUNTING PLATE (2)BLOWER, CROSS FLOW

ASSY, INSTALLATION PLATERIGHT SIDE PANELDRIP PROOF COVERCLIP, COIL SENSORASSY, HEAT EXCHANGERASSY, DRAIN HOSEFAN BEARING VIBRATION ABSORBER SETASSY, DISCH, GRILLE HOR. BLADEASSY BOTTOM FRAME ASSY, PCB (WITH LAMP COVER)PLASMA GENERATOR

1213141516171819202122

23456789

1011

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Downloaded from www.Manualslib.com manuals search engine

Page 51: Wall Mounted L/M/P/311 Series

50

TM-F

T-04

15-B

NO DESCRIPTION NO DESCRIPTION

1 ASSY., CHASSISMOTORBLOWER, CROSS FLOWFAN BUSHMOTOR COVERASSY., INDOOR COILASSY., AIR DISCHARGE HOUSINGASSY., LOUVERPVC HOSE

ASSY., CONTROL BOXASSY., PCB (WITH LAMP COVER)CONTROL BOX COVERSERVICE COVERASSY., MOUNTING PLATEASSY., FRONT COVERFRONT COVERPANELFILTER

101112131415161718

23456789

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Indoor UnitModel : FT20/25LV1L, FT20/25LV1M

Downloaded from www.Manualslib.com manuals search engine

Page 52: Wall Mounted L/M/P/311 Series

51

TM-F

T-04

15-B

NO DESCRIPTION NO DESCRIPTION

1 ASSY., CHASSISMOTORBLOWER, CROSS FLOWFAN BUSHMOTOR COVERASSY., INDOOR COILASSY., AIR DISCHARGE HOUSINGASSY., LOUVERPVC HOSE

101112131415161718

ASSY., CONTROL BOXASSY., PCB (WITH LAMP COVER)CONTROL BOX COVERSERVICE COVERASSY., MOUNTING PLATEASSY., FRONT COVERFRONT COVERPANELFILTER

23456789

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Indoor UnitModel : FTN20/25PV1L, FTN20/25PV1M

Downloaded from www.Manualslib.com manuals search engine

Page 53: Wall Mounted L/M/P/311 Series

52

TM-F

T-04

15-B

NO DESCRIPTION NO DESCRIPTION

1 ASSY., CHASSISMOTORBLOWER, CROSS FLOWFAN BUSHMOTOR COVERASSY., INDOOR COILASSY., AIR DISCHARGE HOUSINGASSY., LOUVERPVC HOSEASSY., CONTROL BOX

11 ASSY., PCB (WITH LAMP COVER)CONTROL BOX COVERSERVICE COVERASSY., MOUNTING PLATEASSY., FRONT COVERFRONT COVERPANELFILTER

PLASMA GENERATOR

2 123 134 14567

15

8

16

9

1718

10

19

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

19

Indoor UnitModel : FT20/25MV1I, FT20/25MV1J FTN20/25MV1I9, FTN20/25MV1J9

Downloaded from www.Manualslib.com manuals search engine

Page 54: Wall Mounted L/M/P/311 Series

53

TM-F

T-04

15-B

Indoor UnitModel: FT311V1L, FT311V1M FTN311V1L, FTN311V1M

12 LED LIGHT BRACKET13 CONTROL BOX COVER14 ASSY. DRAIN HOSE15 AIR SWING MOTOR16 AIR LOUVER 17 ASSY. AIR DISCHARGE HOUSING 18 COIL SENSOR CLIP19 ASSY. FRONT COVER20 SARANET FILTER21 THERMISTOR HOLDER

1 ASSY. INSTALLATION BRACKET 2 ASSY. CHASSIS 3 PIPING CLAMP 4 FAN BUSH BRACKET 5 CROSS FLOW FAN 6 FAN BUSH 7 ASSY., INDOOR COIL 8 SERVICE PANEL 9 CONTROL MODULE 10 FAN MOTOR 11 ASSY, CONTROL BOX

NO DESCRIPTION NO DESCRIPTION

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

1314151617181920

21

Downloaded from www.Manualslib.com manuals search engine

Page 55: Wall Mounted L/M/P/311 Series

54

TM-F

T-04

15-B

Outdoor UnitModel : R09/15CV1

NO. DESCRIPTION NO. DESCRIPTION1 ASSY. BASE PAN

12 ASSY. FRONT PANEL2 ASSY. OUTDOOR COIL13 ASSY. CONTROL PANEL3 VALVE BRACKET14 ASSY. VALVE COVER4 COMPRESSOR15 ASSY. FRONT GRILLE16 PLASTIC HANDLE17 RUBBER GROMMET

5 ASSY. PARTITION6 ASSY. CAP TUBE7 BRACKET, FAN MOTOR8 FAN MOTOR PARTS NOT IN DIAGRAM

CAPACITOR, FAN MOTORCAPACITOR, COMPRESSOR

9 FAN BLADE10 LEFT PANEL

11 RIGHT PANEL

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Downloaded from www.Manualslib.com manuals search engine

Page 56: Wall Mounted L/M/P/311 Series

55

TM-F

T-04

15-B

Outdoor UnitModel : RN10/15FV1

NO. DESCRIPTION NO. DESCRIPTION1 ASSY. OUTDOOR COIL

12 SUCTION PIPE

2 TOP PANEL

13 ASSY. CAP TUBE3 FAN MOTOR BRACKET

14 VALVE BRACKET4 ASSY PARTITION

15 ASSY. VALVE COVER16 ASSY. CONTROL PANEL17 RIGHT PANEL

5 FAN MOTOR6 FAN BLADE7 ASSY. FRONT GRILLE8 ASSY FRONT PANEL9 ASSY BASE PAN

10 COMPRESSOR11 DISCHARGE PIPE

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

17

16

15

1413121110987

6

5

4

3

2 1

Downloaded from www.Manualslib.com manuals search engine

Page 57: Wall Mounted L/M/P/311 Series

56

TM-F

T-04

15-B

Outdoor UnitModel : R18/20CV1, RN20/25CV1

NO. DESCRIPTION NO. DESCRIPTION1 ASSY., BASE PAN2 ASSY., OUTDOOR COIL3 MOTOR BRACKET

13 TERMINAL COVER PANEL

4 FAN MOTOR

14 ASSY., CONTROL PANEL

5 FAN BLADE

15 TOP PANEL

6 VALVE BRACKET 7 ASSY., FLARE VALVE 8 ASSY., FLARE VALVE 9 BLACK PANEL, RIGHT10

16 ASSY., FRONT GRILLE 17 PLASTIC HANDLE 18 ASSY., VALVE COVER 19 ASSY., CAPE TUBE 20 SUCTION PIPE 21 PARTITIONPARTS NOT IN THE DIAGRAMS CAPACITOR, FAN MOTOR CAPACITOR, COMPRESSOR

COMPRESSOR11 FRONT PANEL LEFT 12 SERVICE PANEL

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Downloaded from www.Manualslib.com manuals search engine

Page 58: Wall Mounted L/M/P/311 Series

57

TM-F

T-04

15-B

Model : R25CV1, RN28CV1

1 ASSY. BASE PAN2 ASSY. OUTDOOR COIL3 MOTOR BRACKET4 FAN MOTOR5 FAN BLADE6 VALVE BRACKET7 PARTITION8 COMPRESSOR9 BACK PANEL, RIGHT10 SERVICE PANEL

NO DESCRIPTION NO DESCRIPTION11 FRONT PANEL, LEFT12 TOP PANEL13 ASSY. CONTROL PANEL14 TERMINAL CONTROL PANEL15 ASSY. VALVE COVER16 ASSY. FRONT GRILLE17 PLASTIC HANDLE, SIDE18 DISCHARGE PIPE19 SUCTION PIPE20 ASSY. CAP TUBE

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

Downloaded from www.Manualslib.com manuals search engine

Page 59: Wall Mounted L/M/P/311 Series

58

TM-F

T-04

15-B

Model : R31CV1

1 ASSY. BASE PAN2 ASSY. OUTDOOR COIL3 MOTOR BRACKET4 MOTOR5 FAN BLADE6 ASSY. VALVE BRACKET7 COMPRESSOR8 PANEL, SERVICE9 PANEL, PARTITION10 ASSY., VALVE COVER11 PANEL, RIGHT BACK

NO DESCRIPTION NO DESCRIPTION12 ASSY., PANEL FRONT LEFT13 ASSY, FRONT GRILLE14 ASSY , PANEL TOP15 PLASTIC, HANDLE FRONT 16 PLASTIC HANDLE17 PIPE, SUCTION18 PIPE, DISCHARGE19 ASSY. CAP TUBE20 FELT, COMPRESSOR21 ASSY., CONTROL PANEL

* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.

21

Downloaded from www.Manualslib.com manuals search engine

Page 60: Wall Mounted L/M/P/311 Series

Branches: • Penang Tel: 04-331 1670 • Johor Tel: 07-557 7788 • Pahang Tel: 09-567 6778 • Perak Tel: 05-548 2307 • Melaka Tel: 06-288 1133 • Sabah Tel: 088-722 194 • Sarawak Tel: 082-333 299 • Negeri Sembilan Tel: 06-768 8969 • Kedah Tel: 04-733 0235 • Kelantan Tel: 09-747 4678

GROUP ASSOCIATED (C&L) SDN BHD (109719-M)

Head Office: Tel: 03-7953 8388 Fax: 03-7956 4371Email: [email protected], [email protected]

www. da i k i n . com.m y

Downloaded from www.Manualslib.com manuals search engine