Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-44 A-45
VZ series Piston PumpFeatures Highly intensified output
Adopting the cradle swash plate has achieved high pressure in a compact and light-weight body, resulting in increased output per unit weight.
Low noiseWhile increasing the rigidity of the swash plate structure, the noise level has been substantially reduced thanks to the housing geometry resulting from the state-of-the-art measurement and analysis technologies.
High efficiencyThe spherical valve plate and optimum hydraulic balance realize stable and highly efficient operation over a broad range of operation conditions.
Long lifeAdopting the spherical valve plate with its superior abrasion resistance has improved the anti-contaminant characteristics.
Nomenclature Pressure compensator control
1 Model No.VZ: VZ series piston pump *1
Pump capacity 50: 50.2 cm3/rev 63: 63.0 cm3/rev 80: 79.6 cm3/rev100: 104.6 cm3/rev130: 135.9 cm3/rev
Control method I (Refer to Page A-4 for the applicable models.)A: Pressure compensator controlC: Combination control *2
Pressure adjustment range1: 1.5 to 7 MPa {15 to 70 kgf/cm2}2: 1.5 to 14 MPa {15 to 140 kgf/cm2}3: 3.5 to 21 MPa {35 to 210 kgf/cm2}4: 3.5 to 28 MPa {35 to 280 kgf/cm2} *3
Low pressure adjustment range1: 1.5 to 7 MPa {15 to 70 kgf/cm2}2: 1.5 to 14 MPa {15 to 140 kgf/cm2}3: 3.5 to 21 MPa {35 to 210 kgf/cm2}4: 3.5 to 28 MPa {35 to 280 kgf/cm2} *3
2
7
6 High pressure adjustment range1: 1.5 to 7 MPa {15 to 70 kgf/cm2}2: 1.5 to 14 MPa {15 to 140 kgf/cm2}3: 3.5 to 21 MPa {35 to 210 kgf/cm2}4: 3.5 to 28 MPa {35 to 280 kgf/cm2} *3
Direction of rotation, when viewed from the shaft endR: Clockwise (rightward)
Control method IIH: Pressure feedback methodJ: Solenoid operated method
Voltage code for the solenoid valve<Applied only when control method II is J>A: AC 100 V (50/60 Hz), AC 110 V (60 Hz)B: AC 200 V (50/60 Hz), AC 220 V (60 Hz)P: DC 12 V
Piping directionX: Side port
Design No. (The design No. is subject to change)
Control method IIINo designation: Without remote control systemRC: With remote control system *4
<Applied only when control method I is A>
8
5
4
3
Note: *1 Only petroleum-based hydraulic fluids are acceptable for the VZ series.*2 The combination control is not applicable to VZ130.*3 The 4th pattern of the pressure adjustment range (3.5 to 28 MPa {35 to 280 kg/cm2}) applies only to VZ50, VZ63, VZ80, and
VZ100.*4 The pressure adjustment range with a remote control system is the 4th pattern only (but the 3rd pattern for VZ130).
Combination control
9
10
11
12
Note: JR-G (T) 02 and JRP-G02 are recommended for the remote control system's relief valve. If the vent port is blocked, the pressure compensation structure does not work and the pump operates at a fixed pressure.
Foot supports and piping flanges are not provided with the pump. Order them separately as required by referring to Pages S-2 to S-4.
VZ A R X - 10 1 2 3 4 7 10 11 12
VZ C R X - 101 2 3 5 6 7 8 9 10 11
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-44 A-45
A
PIS
TON
PU
MP
S
Models and pressure adjustment range table Pressure compensator control4 Pressure adjustment range
Code Pressure adjustment rangeMPa {kgf/cm2}
Without remote control system With remote control system
VZ50 VZ63 VZ80 VZ100 VZ130 VZ50 VZ63 VZ80 VZ100 VZ1301 1.5 to 7 { 15 to 70} − − − − −2 1.5 to 14 { 15 to 140} − − − − −3 2 to 21 { 20 to 210} − − − − − − − − −
3 3.5 to 21 {135 to 210} − − − − −4 2 to 28 { 20 to 280} − − − − − −4 3.5 to 28 { 35 to 280} − − − − − −
Code Pressure adjustment rangeMPa {kgf/cm2}
Without remote control system
VZ50 VZ63 VZ80 VZ1001 1.5 to 7 {15 to 70}
2 1.5 to 14 {15 to 140}
3 3.5 to 21 {35 to 210}
4 3.5 to 28 {35 to 280}
Combination control5 Low pressure adjustment range
6 High pressure adjustment range
Code Pressure adjustment rangeMPa {kgf/cm2}
Without remote control system
Pressure feedback method Solenoid operated method
VZ50 VZ63 VZ80 VZ100 VZ50 VZ63 VZ80 VZ1001 1.5 to 7 {15 to 70}
2 1.5 to 14 {15 to 140}
3 3.5 to 21 {35 to 210}
4 3.5 to 28 {35 to 280}
Specifications
Model No.Theoretical
discharge ratecm3/rev
Maximum operating pressure
MPa {kgf/cm2}
Permissible rotational speed
min-1
Discharge rate adjustment range
1800min-1
L/min
Mass(Control method A)
kg
VZ50 50.2 28 {280} 500 to 1800 0 to 90 40
VZ63 63.0 28 {280} 500 to 1800 0 to 113 47
VZ80 79.6 28 {280} 500 to 1800 0 to 143 55
VZ100 104.6 28 {280} 500 to 1800 0 to 188 75
VZ130 135.9 21 {210} 500 to 1800 0 to 244 105
Foot supports and piping flanges are not provided with the pump. Order them separately as required by referring to Pages S-2 to S-4.
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-46 A-47
Hexagonal flat lock nut: 32
L
Decreasing pressure
Increasing pressure
Decreasing pressure
Increasing pressure
Socket for hex key: 8
Socket for hex key: 5
Hexagonal flat lock nut: 16
PC differential pressure adjusting screwNo adjustment required
Pressure adjusting screw
Pressure adjusting screw
Pressure type Low pressure adjustment range High pressure adjustment range
1 1.5 to 7 MPa {15 to 70 kgf/cm2} 1.5 to 7 MPa {15 to 70 kgf/cm2}
2 1.5 to 14 MPa {15 to 140 kgf/cm2} 1.5 to 14 MPa {15 to 140 kgf/cm2}
3 3.5 to 21 MPa {35 to 210 kgf/cm2} 3.5 to 21 MPa {35 to 210 kgf/cm2}
4 3.5 to 28 MPa {35 to 280 kgf/cm2} 3.5 to 28 MPa {35 to 280 kgf/cm2}
Pressure adjustment range [Common to the pressure feedback method (CH) and solenoid operated method (CJ)]
The exact characteristics of the solenoid operated type combination control will be as shown to the right. To be more specific, even if the solenoid is turned on to switch to high pressure operation the discharge rate will not switch to the low quantity range (QL) until the pressure in the circuit reaches the pressure P1 that overcomes the bias spring force that inclines the swash plate.
Pressure adjustment methods Pressure compensator control
Combination control
Decreasing pressure
Increasing pressure
Pressure adjusting screw
Hexagonal flat lock nut: 32
Socket for hex key: 8
Low pressure adjusting screw (PL)
High pressure adjusting screw (PH)
L25
20
15
10
5
0
3rd, 4th pattern
1st, 2nd pattern
Set
pre
ssur
e (M
Pa)
{×10
kgf
/cm
2 }
Pressure adjusting screwProtruding length L (mm)
Pressure adjusting screwNo. of revolutions
9 10 11 12 13 14 15 16 17 18
0 1 2 3 4 5 6
Set
pre
ssur
e (M
Pa)
{×10
kgf
/cm
2 }
Pressure adjusting screwProtruding length L (mm)
Pressure adjusting screNo. of revolutions
25
20
15
10
5
0
3rd, 4th pattern
1st, 2nd pattern
9 10 11 12 13 14 15 16 17 18
0 1 2 3 4 5 6
Pressure adjustment range code
Discharge pressure variation/one revolution of the pressure adjusting screw
1 2.5 MPa/revolution2 4.6 MPa/revolution3 7.9 MPa/revolution
Variation of discharge pressure
VZ50, VZ63VZ80, VZ100
As shown in the graph to the right
VZ130: As shown in the table below
Dis
char
ge ra
te
Decreasing pressure
Increasing pressure
Pressure
Pressure adjustment\rPressure compensator control
Hexagonal flat lock nut: 32
Socket for hex key: 8(VZ130: 5)(VZ130: 16)
L
Counterclockwise Clockwise
VZ50, VZ63, VZ80, VZ100 VZ130D
isch
arge
rate
Pressure
Solenoid OFF
Solenoid ON
P1 = 1.1 to 1.5 MPa {11 to 15 kgf/cm2}P2 = 1.5 MPa {15 kgf/cm2}
QH
QL
P1 P2PL PH
The 1st to 4th patterns correspond to the pressure adjustment range designation codes 1 to 4.
The 1st to 4th patterns correspond to the pressure adjustment range designation codes 1 to 4.
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-46 A-47
A
PIS
TON
PU
MP
S
Relationship between the protruding length of the discharge rate adjusting screw and the discharge rate (pressure compensator control)
The maximum discharge rate can be set to the desired value by turning the discharge rate adjusting screw at the side of the housing. Turning the adjusting screw clockwise decreases the discharge rate. Turning the adjusting screw counterclockwise increases the discharge rate.
Dis
char
ge ra
te
Pressure
Clockwise
Counterclockwise
Discharge rate adjusting screw
Socket for hex key: 5 (VZ63, VZ50)6 (VZ80, VZ100, VZ130)Hexagonal flat
lock nut : 16 (VZ63, VZ50) : 18 (VZ80, VZ100, VZ130)
Increase Decrease
L
Dis
char
ge ra
te (c
m3 /r
ev)
Screw protruding length: L (mm)
100
50
00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
VZ100
VZ80
VZ63
VZ130
VZ50
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-48 A-49
The discharge rate adjusting screws are provided with scales as shown below.
Pump modelScale °
Low quantity adjusting screw
High quantity adjusting screw
VZ50C 0 to 10 0 to 17
VZ63C 0 to 10 0 to 17
VZ80C 0 to 10 0 to 17
VZ100C 0 to 10 0 to 17
(Scale graduation: 1°)
Adjust the discharge rate according to the relevant discharge rate adjustment graph by following the procedure below.• For the low quantity range, read the value for the desired discharge rate on the graph and turn the low quantity adjusting
screw to set the scale position to the read value.• For the high quantity range, read the value for the desired discharge rate on the line corresponding to the value for the low
quantity range on the graph and turn the high quantity adjusting screw to set the scale position to the read value.• When adjusting only the high quantity range, loosen the lock nut and adjust as described above.• When adjusting only the low quantity range, loosen the lock nut on the hight quantity adjustment screw and adjust the
setting for the low quantity range as described above while holding the high quantity adjusting screw in place with a hex key.
Example of adjustmentWhen adjusting the discharge rate of VZ80C to 23 cm3/rev for the low quantity range (QL) and 75 cm3/rev for the
high quantity range (QH)
(1) From the discharge rate adjustment graph for VZ80C in combination control, first read the value for QL = 23 cm3/rev, which is 5°, and adjust the low quantity adjusting screw accordingly.
(2) Then, read the value for QH = 75 cm3/rev on the line for 5° of QL, which is 11°, and adjust the high quantity adjusting screw accordingly.
Discharge rate adjustment graph for VZ80C in combination control
The setting values indicated above may change slightly depending on the conditions of use (fluid temperature, hydraulic fluid type, etc.)For final fine adjustment, repeat the adjustment described above and achieve the setting appropriate for the actual application.
Dis
char
ge ra
te (c
m3 /r
ev)
0 1 2 3 4 5 6 7 8 9 10Low quantity scale (°)
80
70
60
50
40
30
20
10
0
(23)
(75)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17High quantity scale (°)
Low
qua
ntity
sca
le
9
8
7
6
5
4
3
2
1
• Turning the adjusting screw clockwise decreases the discharge rate.
• Turning the adjusting screw counterclockwise increases the discharge rate.
Relationship between the protruding length of the discharge rate adjusting screw and the discharge rate (combination control)
Note: The high quantity adjustment range may be restricted due to the setting for the low quantity range.See the graphs on Page A-49 for details.
Scale setting position (high quantity)Scale setting position (low quantity)
Low quantity scale
Low quantity adjusting screw (QL)Width across flats: 39 (VZ50, VZ63, VZ80, VZ100)
High quantity adjusting screw (QH)Socket for hex key: 8 (VZ50, VZ63, VZ80, VZ100)
High quantity scale
Lock nutHexagonal flat nut: 60 (VZ50, VZ63, VZ80, VZ100)
Lock nutHexagonal flat nut: 24 (VZ50, VZ63, VZ80, VZ100)
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-48 A-49
A
PIS
TON
PU
MP
S
Factory setting of discharge rateThe discharge rate for the high quantity range is factory adjusted to the maximum discharge rate and the discharge rate for the low quantity range is generally factory adjusted as follows.
Pump model Low quantity (QL) setting
VZ50C Scale position: 9°
VZ63C Scale position: 8°
VZ80C Scale position: 8°
VZ100C Scale position: 8°
Discharge rate adjustment graph in combination controlLinear adjustment of the discharge rate for the low quantity range is not possible below
the adjustment range (section indicated by the dashed line).
VZ50C
VZ63C
VZ80C
VZ100C
50
40
30
20
10
0
10
8
6
4
2
9
7
5
3
1
Dis
char
ge ra
te (c
m3 /r
ev)
Low quantity scale (°)
High quantity scale (°)
Low
qua
ntity
sca
le
0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
10987654321
70
60
50
40
30
20
10
0Low quantity scale (°)
High quantity scale (°)
0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Low
qua
ntity
sca
le
Dis
char
ge ra
te (c
m3 /r
ev)
9
8
7
6
5
4
3
2
1
Low
qua
ntity
sca
le
80
70
60
50
40
30
20
10
0Low quantity scale (°)
High quantity scale (°)
0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Dis
char
ge ra
te (c
m3 /r
ev)
9
8
7
6
5
4
3
2
1Low
qua
ntity
sca
le
Dis
char
ge ra
te (c
m3 /r
ev)
100
90
80
70
60
50
40
30
20
10
0
Low quantity scale (°)
High quantity scale (°)
0 1 2 3 4 5 6 7 8 9 10
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-50 A-51
General performance (1800 min-1) Discharge rate setting: maximum
Shaft input characteristics at full cutoff (1800 min-1)
Volume efficiency100
90
80
70
60
0
VZ50
Effi
cien
cy (%
)
0 7 14 21 28
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
Volume efficiencyVZ63100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21 28
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
VZ80100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21 28
Total efficiency
Volume efficiency
Pressure (MPa) {×10 kgf/cm2}
Volume efficiencyVZ100100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21 28
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
Volume efficiencyVZ130100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
(3rd, 4th pattern)
(1st, 2nd pattern)
VZ50
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
(3rd, 4th pattern)
(1st, 2nd pattern)
VZ63
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
(3rd, 4th pattern)
(1st, 2nd pattern)
VZ80
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
VZ100
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
VZ130
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21
Pressure (MPa) {×10 kgf/cm2}
Note: The efficiency varies depending on the discharge rate setting. When selecting the motor capacity, refer to the shaft input characteristics on Page A-52.
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-50 A-51
A
PIS
TON
PU
MP
S
General performance (1500 min-1) Discharge rate setting: maximum
Shaft input characteristics at full cutoff (1500 min-1)
VZ50 Volume efficiency100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21 28
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
Volume efficiencyVZ63100
90
80
70
60
0E
ffici
ency
(%)
0 7 14 21 28
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
Volume efficiencyVZ80100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21 28
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
Volume efficiencyVZ100100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21 28
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
Volume efficiencyVZ130100
90
80
70
60
0
Effi
cien
cy (%
)
0 7 14 21
Total efficiency
Pressure (MPa) {×10 kgf/cm2}
VZ50
(3rd, 4th pattern)
(1st, 2nd pattern)
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
VZ63
(3rd, 4th pattern)
(1st, 2nd pattern)
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
VZ80
(3rd, 4th pattern)
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
(1st, 2nd pattern)
Pressure (MPa) {×10 kgf/cm2}
VZ100
Sha
ft in
put (
kW)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
VZ130
Sha
ft in
put (
kW)
Pressure (MPa) {×10 kgf/cm2}
10
8
6
4
2
00 7 14 21
Note: The efficiency varies depending on the discharge rate setting. When selecting the motor capacity, refer to the shaft input characteristics on Page A-53.
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-52 A-53
Shaft input characteristics (1800 min-1)
Drainage volume characteristics (1800 min-1)
100
80
60
40
20
VZ50 Discharge rate setting (%)
Sha
ft in
put (
kW)
50
40
30
20
10
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
100
80
60
40
20
VZ63 Discharge rate setting (%)
Sha
ft in
put (
kW)
60
50
40
30
20
10
00 7 14 21 28Pressure (MPa) {×10 kgf/cm2}
100
80
60
40
20
VZ80 Discharge rate setting (%)
Sha
ft in
put (
kW)
70
60
50
40
30
20
10
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
100
80
60
40
20
VZ100 Discharge rate setting (%)
Sha
ft in
put (
kW)
100
80
60
40
20
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
100
80
60
40
20
VZ130 Discharge rate setting (%)
Sha
ft in
put (
kW)
100
80
60
40
20
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
At full volume
VZ50
At full-cutoff (1st, 2nd pattern)
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28
At full-cutoff (3rd, 4th pattern)
Pressure (MPa) {×10 kgf/cm2}
At full volume
VZ63
At full-cutoff (3rd, 4th pattern)
At full-cutoff (1st, 2nd pattern)
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28Pressure (MPa) {×10 kgf/cm2}
VZ80
At full-cutoff (1st, 2nd pattern)
At full-cutoff (3rd, 4th pattern)
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28
At full volume
Pressure (MPa) {×10 kgf/cm2}
VZ130
At full volume
At full cutoff
Dra
inag
e ra
te (L
/min
)
20
16
12
8
4
00 7 14 21
Pressure (MPa) {×10 kgf/cm2}
VZ100
At full volume
At full cutoff
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-52 A-53
A
PIS
TON
PU
MP
S
Shaft input characteristics (1500 min-1)
Drainage volume characteristics (1500 min-1)
Discharge rate setting (%)VZ50
100
80
60
40
20
Sha
ft in
put (
kW)
50
40
30
20
10
00 7 14 21 28Pressure (MPa) {×10 kgf/cm2}
Discharge rate setting (%)VZ63
100
80
60
40
20
Sha
ft in
put (
kW)
50
40
30
20
10
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
Discharge rate setting (%)VZ80
100
80
60
40
20
Sha
ft in
put (
kW)
60
50
40
30
20
10
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
Discharge rate setting (%)VZ100
100
80
60
40
20
Sha
ft in
put (
kW)
100
80
60
40
20
00 7 14 21 28
Pressure (MPa) {×10 kgf/cm2}
Discharge rate setting (%)VZ130
100
80
60
40
20
Sha
ft in
put (
kW)
100
80
60
40
20
00 7 14 21
Pressure (MPa) {×10 kgf/cm2}
VZ50
At full-cutoff (3rd, 4th pattern)
At full-cutoff (1st, 2nd pattern)
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28
At full volume
Pressure (MPa) {×10 kgf/cm2}
VZ63
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28
At full-cutoff (1st, 2nd pattern)
At full-cutoff (3rd, 4th pattern)
At full volume
Pressure (MPa) {×10 kgf/cm2}
VZ80
At full-cutoff (3rd, 4th pattern)
At full-cutoff (1st, 2nd pattern)
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28
At full volume
Pressure (MPa) {×10 kgf/cm2}
VZ100
At full cutoff
Dra
inag
e ra
te (L
/min
)
10
8
6
4
2
00 7 14 21 28
At full volume
Pressure (MPa) {×10 kgf/cm2}
VZ130
At full cutoff
At full volumeDra
inag
e ra
te (L
/min
)
20
16
12
8
4
00 7 14 21
Pressure (MPa) {×10 kgf/cm2}
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-54 A-55
Noise characteristics (JIS B 8350, measuring position: 1 m from pump front)
Input rotational speed Fluid used Oil temperature
1800 min-1 1500 min-1 Equivalent to ISO VG32 50°C
VZ5075
70
65
60
55
500 5 10 15 20 25 28
At full cutoff
At full volume
Noi
se le
vel (
dB-A
)
Pressure (MPa) {×10 kgf/cm2}
VZ6375
70
65
60
55
500 5 10 15 20 25 28
At full cutoff
At full volume
Noi
se le
vel (
dB-A
)
Pressure (MPa) {×10 kgf/cm2}
VZ8075
70
65
60
55
500 5 10 15 20 25 28
At full cutoff
At full volume
Noi
se le
vel (
dB-A
)
Pressure (MPa) {×10 kgf/cm2}
80
75
70
65
60
55
50
VZ100
0 5 10 15 20 25 28
At full cutoff
At full volume
Noi
se le
vel (
dB-A
)
Pressure (MPa) {×10 kgf/cm2}
80
75
70
65
60
55
50
VZ130
At full cutoff
At full volume
2520151050
Noi
se le
vel (
dB-A
)
Pressure (MPa) {×10 kgf/cm2}
1500 min-1
1800 min-1
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-54 A-55
A
PIS
TON
PU
MP
S
External dimension diagram
Oil filler port for the pump case
Rc½
(Dra
in
port
heig
ht)
Effective thread depth 27
Effective thread depth 22
Drain port
M12 × 1.75
M10 × 1.5
210148
78
φ38.1
224
14835.7 55.538
φ25.4
69.9
15.5 10226
258
26.2
122
75 52.4
Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
Pressure adjusting screw (clockwise: pressure increase)Socket for hex key: 8Hexagonal flat lock nut: 32
120 maximum
93
72 72
PC valve
73 73
120 maximum 121
7313
3
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 5Hexagonal flat lock nut: 16
φ14.3
�6.3 × 38+0.0150
0
φ25.
4 −0
.05
0φ1
01.6
−0.
05
0
28.1
9 −0
.25
VZ50ARX-10
Mass: 40 kg
Rc½
Oil filler port for the pump case
Drain portφ38.1
249.5210.5
14878
41
224
14835.7
φ25.4
26.2226
15.5 10
258270
52.4
75(Dra
in
port
heig
ht)
(Ven
t po
rt he
ight
)
122
117
69.9
55.538
PC differential pressure adjusting screw (factory adjusted)
117 maximum
PC remote control valve
93
72 72 73 73
120 maximum 121
7313
3
φ14.3
Vent port -20UNF-2B SAE straight thread, O-ring boss(For the optional -20UNF flare joint, refer to Page S-4.)
Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
Effective thread depth 27
Effective thread depth 22
M12 × 1.75
M10 × 1.5
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 5Hexagonal flat lock nut: 16
�6.3 × 38+0.0150
0
φ25.
4 −0
.05
0
28.1
9 −0
.25
716
716
0φ1
01.6
−0.
05
VZ50A4RX-10RC
Mass: 40.5 kg
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-56 A-57
External dimension diagram
127 maximum
138
95
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
275256
216148
78
Discharge rate adjusting screw(low quantity)
Discharge rate adjusting screw(high quantity)
219 maximum
φ14.3
7313
3
73 7375
121
(Dra
in
port
heig
ht)
122
52.4
φ25.4
26.272 72226
258
15.5 10
224
14835.7
φ38.1
69.9
55.538
Oil filler port for the pump case
Rc½Drain port
Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
Effective thread depth 27
Effective thread depth 22
M12 × 1.75
M10 × 1.5
0
φ25.
4 −0
.05
0
28.1
9 −0
.25
�6.3 × 38+0.0150
0φ1
01.6
−0.
05
VZ50CRHX-10
Mass: 45 kg
216.
595
72 72
231.
5 (A
C),
234.
5 (D
C)
Cable diameter φ6 to φ10
SolenoidKSO-GO2-2B�-��-C
219 maximum
φ14.3
7313
3
7373
75
121
275250
14878
(Dra
in
port
heig
ht)
122
52.4
φ25.4
26.2226
258
15.5 10
224
148216
35.7
69.9
55.538
φ38.1
127
max
imum
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
Discharge rate adjusting screw(low quantity)
Discharge rate adjusting screw(high quantity)
Oil filler port for the pump case
Rc½Drain port
�6.3 × 38+0.0150
0
φ25.
4 −0
.05
0
28.1
9 −0
.25
Effective thread depth 27
Effective thread depth 22
M12 × 1.75
M10 × 1.5
Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
0φ1
01.6
−0.
05
VZ50CRJX-10
Mass: 46.5 kg
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-56 A-57
A
PIS
TON
PU
MP
S
External dimension diagram
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 5Hexagonal flat lock nut: 16
126 maximum 127
57.3 57.3
57.3
57.3
φ14.3
138
78Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
Pressure adjusting screw (clockwise: pressure increase)Socket for hex key: 8Hexagonal flat lock nut: 32
117 maximum
95
75 75
PC valve
Oil filler port for the pump case
Rc¾
(Dra
in
port
heig
ht)
Effective thread depth 27
Effective thread depth 22
Drain port
M12 × 1.75
M10 × 1.5
229164
89
φ38.1
243
16635.7 55.538
φ25.4
69.9
16.5 10245
277
26.2
127
8052
.4
0φ3
1.75
−0.
05
0
35.3
5 −0
.25
�7.94 × 38+0.03+0.015
0φ1
27 −
0.05
VZ63ARX-10
Mass: 47 kg
126 maximum 127
57.3 57.3
57.3
57.3
φ14.3
138
78
PC differential pressure adjusting screw (factory adjusted)
PC remote control valve
114 maximum
95
75 75
Oil filler port for the pump case
Drain port
φ38.1
268.5
229164
89
38
243
16635.7
φ25.4
26.2245
16.5 10
289277
52.4
80(Dra
in
port
heig
ht)
(Ven
t po
rt he
ight
)
127
119
69.9
55.538
Rc¾
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 5Hexagonal flat lock nut: 16
Vent port -20UNF-2B SAE straight thread, O-ring boss(For the optional -20UNF flare joint, refer to Page S-4.)
Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
Effective thread depth 22M10 × 1.5
Effective thread depth 27M12 × 1.75
0φ3
1.75
−0.
05
0
35.3
5 −0
.25
�7.94 × 38+0.03+0.015
716
716
0φ1
27 −
0.05
VZ63A4RX-10RC
Mass: 47.5 kg
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-58 A-59
External dimension diagram
226 maximumφ14.3
127
57.3 57.3
57.3
57.3
80
7813
8
124 Maximum
98
75 75
141
Oil filler port for the pump case
Rc¾
(Dra
in
port
heig
ht)
Drain port
275235
16489
φ38.1
243
16635.7 55.538
φ25.4
69.9
16.5 10245
277294
26.2
127
52.4
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
Discharge rate adjusting screw(low quantity)
Discharge rate adjusting screw(high quantity)
Effective thread depth 22M10 × 1.5
Effective thread depth 27M12 × 1.75
Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
0φ3
1.75
−0.
05
0
35.3
5 −0
.25
�7.94 × 38+0.03+0.015
0φ1
27 −
0.05
VZ63CRHX-10
Mass: 54 kg
226 maximum
φ14.3
127
57.3 57.3
57.3
57.380
7813
8
98
75 75
219.
5
Cable diameter φ6 to φ10
234.
5 (A
C),
237.
5 (D
C)
SolenoidKSO-GO2-2B�-��-C
φ38.1
275235
16489
243
235
166
35.7
φ25.4
26.2245
16.5 10
294277
52.4
(Dra
in
port
heig
ht)
127
69.9
55.538
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
Oil filler port for the pump case
Drain port
Discharge rate adjusting screw(low quantity)
Discharge rate adjusting screw(high quantity)
Discharge portSize 1 split flange boss(SAE J518)
Suction port Size 1½ split flange boss(SAE J518)
Effective thread depth 22M10 × 1.5
Effective thread depth 27M12 × 1.75
0φ3
1.75
−0.
05
035
.35
−0.2
5
�7.94 × 38+0.03+0.015
124
max
imum
Rc¾
0φ1
27 −
0.05
VZ63CRJX-10
Mass: 55.5 kg
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-58 A-59
A
PIS
TON
PU
MP
S
External dimension diagram
262.518.5 10
3855.5177.5
262.577.8
132
85
42.9
30.2
302.5
φ50.8
φ31.8
58.7
(Dra
in
port
heig
ht)
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 6Hexagonal flat lock nut: 18
135 maximum 131
57.3 57.3
57.3
57.3
φ14.3
143
83
242.5175.5
92.5
114 maximum
100
80 80
PC valve
Oil filler port for the pump case
Rc¾Drain port
Pressure adjusting screw (clockwise: pressure increase)Socket for hex key: 8Hexagonal flat lock nut: 32
Discharge portSize 1¼ split flange boss(SAE J518)
Suction port Size 2 split flange boss(SAE J518)
Effective thread depth 28M10 × 1.5
Effective thread depth 27M12 × 1.75
�7.94 × 38+0.03+0.015
0φ3
1.75
−0.
05
0
35.3
5 −0
.25
0φ1
27 −
0.05
VZ80ARX-10
Mass: 55 kg
262.518.5 10
55.5177.5262.577
.8
132
85
124
42.9
30.2
302.5
φ50.8
φ31.8
(Dra
in
port
heig
ht)
(Ven
t po
rt he
ight
)
135 maximum 131
57.3 57.3
57.3
57.3
φ14.3
143
83
243282
175.592.5
35
PC differential pressure adjusting screw (factory adjusted)
PC remote control valve111 maximum
100
80 80
38
Vent port -20UNF-2B SAE straight thread, O-ring boss(For the optional -20UNF flare joint, refer to Page S-4.)
Oil filler port for the pump case
Rc¾Drain port
Discharge portSize 1¼ split flange boss(SAE J518)
Suction port Size 2 split flange boss(SAE J518)
Effective thread depth 28M10 × 1.5
Effective thread depth 27M12 × 1.75
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 6Hexagonal flat lock nut: 18
�7.94 × 38+0.03+0.015
0φ3
1.75
−0.
05
0
35.3
5 −0
.25
716
716
58.7
0φ1
27 −
0.05
VZ80A4RX-10RC
Mass: 55.5 kg
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-60 A-61
External dimension diagram
57.3 57.3
232 maximumφ14.3
131
57.3
57.3
8314
3
(Dra
in
port
heig
ht)
φ50.8
262.5177.5
42.955.5
φ31.8
77.8
18.5 10262.5
302.5307.5
30.2
132
85
121 maximum
103
146
80 80
92.5
288.5248.5
175.2
38
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
Discharge portSize 1¼ split flange boss(SAE J518)
Suction port Size 2 split flange boss(SAE J518)
Effective thread depth 28M10 × 1.5
Effective thread depth 27M12 × 1.75
0φ3
1.75
−0.
05
0
35.3
5 −0
.25
�7.94 × 38+0.03+0.015
Oil filler port for the pump case
Discharge rate adjusting screw(low quantity)
Discharge rate adjusting screw(high quantity)
Rc¾Drain port
58.7
0φ1
27 −
0.05
VZ80CRHX-10
Mass: 60 kg
232 maximum
φ14.3
131
57.3
57.3
57.357.3
8314
3
φ50.8
262.5248.5
55.5177.5
φ31.8
30.2262.5
18.5 10
302.5307.5
(Dra
in
port
heig
ht)
132
77.8
42.9
85
103
239.
5 (A
C),
242.
5 (D
C)
224.
5
Cable diameter φ6 to φ10
SolenoidKSO-GO2-2B�-��-C
80 80
92.5
288.5248.5
175.2
38
121
max
imum
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
Oil filler port for the pump case
Discharge rate adjusting screw(low quantity)
Discharge rate adjusting screw(high quantity)
Rc¾Drain port
0φ3
1.75
−0.
05
0
35.3
5 −0
.25
�7.94 × 38+0.03+0.015
Effective thread depth 28M10 × 1.5
Discharge portSize 1¼ split flange boss(SAE J518)
Suction port Size 2 split flange boss(SAE J518)
Effective thread depth 27M12 × 1.75
0φ1
27 −
0.05
58.7
VZ80CRJX-10
Mass: 61.5 kg
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-60 A-61
A
PIS
TON
PU
MP
S
External dimension diagram
95168
255
150
145
92
57.3 57.3
57.3
57.3
φ15±0.4
18842.9
27477.8
9258
.7
30.2274
318
17 12.5
99.573
φ50.8
φ30
PC valve104 maximum
115
90 90
Oil filler port for the pump case
Rc¾Drain port
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 6Hexagonal flat lock nut: 18
Pressure adjusting screw (clockwise: pressure increase)Socket for hex key: 8Hexagonal flat lock nut: 32
Discharge portSize 1¼ split flange boss(SAE J518)
Suction port Size 2 split flange boss(SAE J518)
Effective thread depth 28M12 × 1.75
Effective thread depth 27M12 × 1.75
�11.11 × 73+0.0250
0φ4
4.45
−0.
05
49.3
±0.1
3
0φ1
27 −
0.05
157 maximum
VZ100ARX-10
Mass: 75 kg
φ50.8
φ30
PC remote control valve
PC differential pressure adjusting screw (factory adjusted)
φ15±0.4
138
(Dra
in
port
heig
ht)
17 12.530.2
318274
58.7
9277
.8
42.9
274
7399.5188 150157 maximum
145
9257
.357
.3
57.357.39090
115139
(Ven
t po
rt he
ight
)
101 maximum
25
95168
255.5294.5
Vent port -20UNF-2B SAE straight thread, O-ring boss(For the optional -20UNF flare joint, refer to Page S-4.)
Oil filler port for the pump case
Rc¾Drain port
Discharge portSize 1¼ split flange boss(SAE J518)
Suction port Size 2 split flange boss(SAE J518)
Effective thread depth 28M12 × 1.75
Effective thread depth 27M12 × 1.75
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 6Hexagonal flat lock nut: 18
�11.11 × 73+0.0250
0φ4
4.45
−0.
05
49.3
8 ±0
.13
716
716
0φ1
27 −
0.05
VZ100A4RX-10RC
Mass: 75.5 kg
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-62 A-63
External dimension diagram
Mass: 80 kg
Mass: 81.5 kg
Suction port Size 2 split flange boss(SAE J518)
114 maximum
159
9090
116
92
Discharge portSize 1¼ splitflange boss(SAE J518)
265 maximum 150
57.3
57.3
145
92
57.3 57.3 φ15
Turning directionTurning direction
Oil filler port for the pump case
Drain portRc¾
Discharge rate adjusting screw(low quantity)Discharge rate adjusting screw(high quantity)
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
326286
16895
77.8
58.7
φ50.8
φ30
274M12 × 1.75Effective thread depth 27
M12 × 1.75Effective thread depth 28
42.9 188 99.5
73
30.2274
318
17 12.5
49.3
±0.1
3
+0.025�11.11 0 × 73
±0.4
0φ1
27 −
0.05
0φ4
4.45
−0.
05
Cable diameterφ6 to φ10
11623
4.5
90 90
265 maximum 150
57.3
57.3
145
92
57.3 57.3
92
326286
16895
77.8
58.7
274
42.9
188 99.573
30.2274
318
17 12.5
286
SolenoidKSO-GO2-2B�-��-C
High pressure adjusting screw (PH)Socket for hex key: 8Hexagonal flat lock nut: 32
Socket for hex key: 8Hexagonal flat lock nut: 32
Low pressure adjusting screw (PL)
Oil filler port for the pump caseDrain portRc¾
Discharge rate adjusting screw(low quantity)Discharge rate adjusting screw(high quantity)φ50.8
249.
5 (A
C),
252.
5 (D
C)
Suction port Size 2 split flange boss(SAE J518)
Discharge portSize 1¼ splitflange boss(SAE J518)
M12 × 1.75Effective thread depth 28
φ30
M12 × 1.75Effective threaddepth 27
49.3
±0.1
3
Turning directionTurning direction
φ15 ±0.4
+0.025�11.11 0 × 73
0φ1
27 −
0.05
0φ4
4.45
−0.
05
VZ100CRHX-10
VZ100CRJX-10
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-62 A-63
A
PIS
TON
PU
MP
S
External dimension diagram
Mass: 105 kg
Mass: 105 kg
Effective thread depth 30
Effective thread depth 27
M16 × 2
M12 × 1.75
φ63.5
325
50.8
φ38.1
88.9
35.7325
24 12.5
377
100
99.573
Discharge portSize 1½ splitflange boss(SAE J518)
Suction portSize 2½ split flange boss(SAE J518)
95 95
Pressure adjusting screw(clockwise: pressure increase)Socket for hex key: 5Hexagonal flat lock nut: 16
310217
225Drain port Rc¾
PC valve
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 6Hexagonal flat lock nut: 18
165 155
80.8 80.8
80.8
80.8
100
198
PC differential pressureadjusting screw(factory adjusted)
69.9
49.3
±0.1
3
+0.025�11.11 0 × 73
φ21.3 ±0.4
0φ4
4.45
−0.
05
0φ1
52.4
−0.
05
Oil filler port for the pump case
325
50.8
88.9
35.7325
24 12.5
377
100
99.573
Vent port Rc¼
Safety valveadjusting screw
95 95
310217
225
PC remote control valve
165 155
80.880.8
80.8
80.8
100
198
Drain port Rc¾
φ63.5
Effective thread depth 30M16 × 2
Suction portSize 2½ split flange boss(SAE J518) Effective thread depth 27
M12 × 1.75
φ38.1
Discharge portSize 1½ splitflange boss(SAE J518)
69.9
49.3
±0.1
3
Discharge rate adjusting screw (clockwise: discharge rate decrease)Socket for hex key: 6Hexagonal flat lock nut: 18
φ21.3 ±0.4
+0.025�11.11 0 × 73
PC differential pressureadjusting screw(factory adjusted)
Oil filler port for the pump case
0φ4
4.45
−0.
05
0φ1
52.4
−0.
05
VZ130ARX-10
VZ130ARX-10RC
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
A-64 A-65
Sectional structural diagram
VZ80
VZ50 VZ63 VZ80 VZ100 VZ130
Part No. Part name Specifications Material Quantity3 O-ring JIS B 2401 1B-G35 JIS B 2401 1B-G40 JIS B 2401 1B-G45 NBR 212 O-ring AS568-908 (HS90) AS568-910 (HS90) NBR 115 O-ring JIS B 2401 1B-G120 JIS B 2401 1B-G125 JIS B 2401 1B-G135 JIS B 2401 1A-G150 JIS B 2401 1A-G160 NBR 121 O-ring JIS B 2401 1B-P7 NBR 627 O-ring AS568-908 (HS90) NBR 136 Oil seal TCV284811 TCV385811 TCN487012 NBR 138 O-ring AS568-234 (HS90) AS568-238 (HS90) NBR 142 Cylinder roller bearing NUP2206C3 NUP208C3 NUP2208C3 NUP2210G1C3 NUP2210G1C3 143 Needle bearing NK29/30RV1 NK32/30RV2 NK37/30RV1 NK40/30RV1+IR354030C NK43/30RV1+IR384330C 146 O-ring JIS B 2401 1B-P10A JIS B 2401 1B-P12 NBR 147 Backup ring JIS B 2407 T2P10A JIS B 2407 T2P12 153 O-ring AS568-910 (HS90) NBR 173 O-ring JIS B 2401 1B-P20 NBR 177 O-ring AS568-903 (HS90) NBR 1
67 68 55 27 2653 52 25
13 21
41 38 36
40 33 34
58
57
56
14
21
135 39422219 2030 1231 321510 4316
2
3
4 48
49 4746 54
45
21636261
78
77
76
75
74
73
18
64
65 66
72 71 8 7 6 3 9
5
28 29 24 2310