8

VWHPV - gblockingsystems.co.uk Systems.pdf · Using the HandNet software for template management, thousands of units can be linked together to form a system that communicates alarms

Embed Size (px)

Citation preview

BiometricSystems

60

Ac

cu

fac

e F

ac

ial R

ec

og

nit

ion

www.gblockingsystems.co.uk

61

Ac

cu

fac

e F

ac

ial R

ec

og

nitio

n

www.gblockingsystems.co.uk

62

Ac

cu

fac

e F

ac

ial R

ec

og

nit

ion

www.gblockingsystems.co.uk

63

Sc

an

-in B

iom

etric

Syste

m

NETWORKED OPTIONS

• RJ45 Socket required at each door

• Fixed IP Address required for each door

• TCP/IP Interface Board required for each controller

• Maximum number of doors that can be networked using Scan-in Software

and Controllers is 12no. If you use the Scan-in System in conjunction with

Paxton Net2 the number of Networked doors can be greatly increased.

**Please Contact us for more detail**

PC Requirements for Software

Operating System Windows 95, 98, XP & Vista

Minimum Requirement Microsoft Office 2000

3MB of Ram

Ethernet port (TCP/IP)

64

Ha

nd

Ke

y I

I B

iom

etr

ic H

an

d G

eo

me

try R

ea

de

r The HandKey® II biometric reader utilises field-proven hand geometrytechnology. It maps and verifies the size and shape of a person’s hand inless than one second and allows access only to authorised people withoutthe hassle of using a card or key.

HandKey II hand geometry technology provides a more economical solutionthan card-base systems because your hand is your card. Not only is the levelof security increased using biometrics, but there are fewer lost or stolencards and administrative costs are reduced.

The HandKey II biometric solution brings the true security and convenienceof biometric technology to any access control application. The HandKey IIcan be used as a stand-alone unit or as part of a networked system. Tens ofthousands of HandKeys are already installed in applications that range fromUniversities and day care centres to airports and prisons. Users appreciatedhow easy the system is to use and the convenience of not having to keeptrack of a credential.

BENEFITS

• Field proven in high volume applications

• Saves money over card-based systems

• Easy to use and install

• Increases convenience by eliminating cards

• Integrates into existing systems

• BioCote® antimicrobial agent is applied to the platen of each unit

• A blue hand outline printed on the platen makes using the HandKey easier to use

Door control and monitoring

Each HandKey II is a complete, integrated door controller providing lock operation, request-for-exit and alarm monitoring. Biometric templatesand decision making capability reside locally, ensuring your doors are always secure and will continue to operate properly even if allcommunication to the main access control system is lost.

Stand-alone or fully integrated

HandKey readers can be used as a stand-alone unit or as part of an integrated access control system. The units easily integrate into existingsystems using the card reader emulation mode.Using the HandNet software for template management, thousands of units can be linked together to form a system that communicates alarmsand transactions in real time, provides activity, user and systems reports, and allows supervised user enrollment and deletions at any reader. Avariety of communications options, including dial-up modems and ethernet, allow you to design a system that’s right for your facility or application.

www.gblockingsystems.co.uk

65

Ha

nd

Ke

y II B

iom

etric

Ha

nd

Ge

om

etr

y R

ea

de

r

Antimicrobial Protection

A BioCote® antimicrobial agent applied during manufacturing of the HandKey provides a durable, safe and hygienic finish that keeps theplaten’s surface cleaner and more hygienic.

Blue Hand Outline

The HandKey comes standard with a blue hand outline printed on the platen. This hand outline will help users place their hand consistently inthe right place on the platen when using the terminal and decrease initial enrollment time.

SpecificationsPart No. HK-2 Card reader output Weigand, magnetic strip, barcodeDimensions 223mm (w) Duress Code 1 leading digit (user definable)

296mm (h) Regulatory FCC, CE, UL294217mm (d) Door Controls Request to Exit input (switch or keypad),

Weight 2.7kg Door switch input, door lock output.Power 12 to 24vdc or 12 to 24vac 50-60 Hz, 7 (open collector, 5vdc present, sinks to

watts ground, 100 mA max)Environment Operating: 32°F to 113°F (0°C to 45°C) Alarm monitoring Tamper, door forced, duress

Relative humidity: 20% to 80% NC Event monitoring There are a variety of monitoring optionsNon-operating (storage): including events such as: invalid ID, time14°F to 140°F (-10°C to 60°C) zone violation, ID refused, try again,Relative humidity: 5% to 85% NC power failure

Verification time Less than one second Time zones 62 user definable time zonesMemory retention Up to 5 years via standard internal Unlimited holidays

lithium battery Auxiliary outputs 3 user definableTransaction 8120 transactions (open collector, 5vdc present,storage sinks to ground, 100mA max)ID number length 1 to 10 digits from keypad or card Auxiliary inputs 2 user definableUser capacity 512 users expandable to 32,000 (open collector, 5vdc present,Template size 9 bytes sinks to ground, 100mA max)Communications RS-485 (4 and 2 wire) Options BB-200 operational battery back up

RS-232 serial print support DC-102 data convertor for use with handnetor network communications software

Baud rate 300 to 28.8 kps EM-801 Memory expansion - 9,728 usersCard reader input Proximity, weigand, magnetic stripe, bar EM-803 Memory expansion - 32,512 users

code (5vdc provided by hand reader) EN-200 Ethernet comms module

www.gblockingsystems.co.uk