4
Vista ® A total breakthrough in transmission color and haze measurement measure color the way your eye sees it

Vista - HunterLab › vista-brochure.pdf · 2020-01-30 · Vista ensures the best value and the lowest total cost of ownership with a low initial investment cost, and low maintenance

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Vista - HunterLab › vista-brochure.pdf · 2020-01-30 · Vista ensures the best value and the lowest total cost of ownership with a low initial investment cost, and low maintenance

Vista®

A total breakthrough in transmission color and haze measurement

measure color

the way your eye sees it

Page 2: Vista - HunterLab › vista-brochure.pdf · 2020-01-30 · Vista ensures the best value and the lowest total cost of ownership with a low initial investment cost, and low maintenance

• USB2.0

• Spillresistantsamplecompartmentprotectsvitalelectroniccomponentsfromdamage.

• Sleek,ergonomicdesignthatcomplimentsanylaboratoryenvironment.

• Compactfootprintminimizestheneedforvaluablebenchspace.

PERFORMANCE AND RELIABILITY

Longlife,fullspectrumLEDilluminationcombinedwithanunprecedenteddegreeofprecisionprovideindustry

leadingperformanceandaccuracyformeasurementofbothcolorandhaze.

AFFORDABILITY

Getmoreforless.Vistaensuresthebestvalueandthelowesttotalcostofownershipwithalowinitialinvestment

cost,andlowmaintenanceandservicecosts.

Vista®isafeaturerich,smallfootprint,visiblelighttransmissionspectrophotometerthatsimultaneously

measuresboththecolorandhazeoftransparent/translucentsamples.Designedtomeetuserdemandsfor

simplicity,accuracy,reliabilityandaffordability,Vista®iscapableofmeasuringthecolorandhazeofawide

rangeofsamplesinoneeasymeasurement,whileprovidingtheuserwithanintuitiveandeasytouseinterface.

A Total Breakthrough in Color Transmission and Haze Measurement!

• Newmodularsample

handlingsystemdesigned

tosimplifythemeasurement

processandimprovemeasurement

throughputandproductivity.

Page 3: Vista - HunterLab › vista-brochure.pdf · 2020-01-30 · Vista ensures the best value and the lowest total cost of ownership with a low initial investment cost, and low maintenance

• COLOR&HAZEMEASUREMENT

• FAST• ACCURATE

• COST EFFICIENT

• MicroUSB

• Ethernet

• Removabledoorallowsformeasurementsoflargersamples.

MEASUREMENT

• Simultaneousmeasurementofbothcolorandhazeinoneeasystep

-providestheQCandQAindicatorsneededforincreasedproduct

integrityandimprovedmanufacturingprocesses.

• One-touchstandardizationofbothcolorandhaze-reduces

userstepsandvaluabletime.

USER INTERFACE

• Easytoread7"touchscreendisplay.

• Intuitive,menudriveninterfaceiseasytouseandeasytonavigate,requiringlittletraining.

• Userscanselectfromanumberofpresetworkspacesdesignedspecificallyfortheirapplication,ortheycancreatetheirownworkspacescustomizedtotheirneeds.

Amongthemanyfeaturesbuilt-inarecustomizableworkspaces,multipledataviews,andthemostwidelyused

transmissioncolorandhazescalesandindicesavailable,includingPt-Co/Hazen/APHA, Gardner Color, Haze %,

Opalescence, Y Total Transmission, Saybolt, Absorbance, CIE Spectral Data, and 3 major Pharmacopoeias:

US, EU, and Japanese.

• VistaprovidessimultaneousColorandHazemeasurementsofawiderangeofsamples.

Page 4: Vista - HunterLab › vista-brochure.pdf · 2020-01-30 · Vista ensures the best value and the lowest total cost of ownership with a low initial investment cost, and low maintenance

Rev. A

•Additionalaccessoriesandsamplehandlingfixturesavailable. Formoreinformationgoto:www.hunterlab.com/vista

Content subject to change without notice.

Hunter Associates Laboratory Inc., 11491 Sunset Hills Road, Reston, VA 20190-5280Tel 703.471.6870 • Fax 703.471.4237 • [email protected] • www.hunterlab.com

ISO 9001 Certified; Certified

07/16

Accessories

D02-1017-193 Self-CenteringSampleHolder

Theself-centeringsampleholdertakestheguessworkoutofcell

placementfortotalorregulartransmittance,ensuringprecisionand

accuracyeverytime.Thesimpledesignensuresproperdistance

andalignmentofthecellorsample,eliminatinginconsistencies

fromcelltocellandusertouser.

D02-1017-390 Semi-MicroCellHolderfor Haze Measurement

Thiscellholderpositionssemi-microanalyticalplasticcellsforrepeatable

totaltransmittanceandhazemeasurements.Alsoaccommodates

semi-micro10mmplasticcellswithoutsidepathlengthdimensionnot

exceeding12.42(pathlength)x12.50mm(0.489x0.492inches)and

requiresD02-1017-192Multi-FunctionSampleHolder.Astarterkitofthree

PMMAplasticcellsisincludedwiththiscellholder.

D02-1017-223 UniversalAdapterBasePlate

Thisuniversaladapterbaseplatewith(2)accessorymountingboltsis

designedtoaccommodatethird-partysampleholders.Measuring

5”x3.75”(127mmx95.25mm)thisbaseplatehas20individual0.25”

(6.35mm)threadedholesthatarespacedina1”x1”(25.4mmx25.4mm)

gridpattern.

L02-1017-471 Round Vial & Preform Holder

ThispreformholderrequirestheMulti-FunctionSampleHolder

(D02-1017-192),securelypositioningthepreformeithervertically

orhorizontallyforaccuratetransmittancecolormeasurement.

ItisnotintendedforHazemeasurementsofpreforms.

D02-1017-192 Multi-FunctionSampleHolder

Thisholderisdesignedtomeasurecolor,transmittancehazecompliant

withASTMD1003ProcedureB.Thereversibledesignallowsbothtotal

andregulartransmittancemeasurementsbyeitherplacingandholding

thesampledirectlyagainstthesphereorthereceptorport,ensuring

precision,accuracyandconsistencyofsampleplacementforfilms,

plasticsandliquids.Thissampleholderisalsothebaseunitforother

optionalcellholdersandaccessories.

D02-1017-344 MacroCellHolderforHazeMeasurement

Thiscellholderispreciselydesignedtoholdmacroanalyticalcells

forrepeatabletotaltransmittanceandhazemeasurements.Also

accommodatesplasticcellsandrequiresD02-1017-192Multi-Function

SampleHolder.AstarterkitofthreePMMAplasticcellsisincluded

withthiscellholder.