4
BWF FTI Spa Sede legale I-21042 Caronno Pertusella (Va) I-21045 Milano vicolo Maria Bianchi 119 via A. Sangiorgio 12 Tel. +39 02.96451722 R.E.A. 291755 Fax. +39 02.96451726 C.F. / P. IVA e Reg. Imp. Mi www.bwf-fti.it [email protected] 00730590155 VISIOLITE LEAK DETECTION SYSTEM Identifying filter bag damage and bad seals at the tubesheet is a time consuming and often in accurate process. The BWF FTI – Visiolite Leak detection System from BWF FTI make it easy to see problem spots while the time it takes to complete a visual inspection. The process utilizes a monochromatic light to locate the presence of an injected fluorescent powder, which highlights potential problem spots in luminescent colour. When the powder is distributed (inject 0,5 kg every 100 m 2 of filter surface) through the baghouse, it follows the path of least resistance to escape – leaving behind tell- tale accumulations weld cracks, misaligned metal enclosures and media damages. INFO INFO

Visiolite Manuale English Version PDF

Embed Size (px)

DESCRIPTION

Leak detection technique by Visiolite

Citation preview

Page 1: Visiolite Manuale English Version PDF

BWF FTI Spa Sede legale I-21042 Caronno Pertusella (Va) I-21045 Milano vicolo Maria Bianchi 119 via A. Sangiorgio 12 Tel. +39 02.96451722 R.E.A. 291755 Fax. +39 02.96451726 C.F. / P. IVA e Reg. Imp. Mi www.bwf-fti.it – [email protected] 00730590155

VISIOLITE LEAK DETECTION SYSTEM Identifying filter bag damage and bad seals at the tubesheet is a time

consuming and often in accurate process. The BWF FTI – Visiolite Leak

detection System from BWF FTI make it easy to see problem spots while

the time it takes to complete a visual inspection.

The process utilizes a monochromatic light to locate the presence of an

injected fluorescent powder, which highlights potential problem spots in

luminescent colour.

When the powder is distributed (inject 0,5 kg every 100 m2 of filter

surface) through the baghouse, it follows the path of least resistance to

escape – leaving behind tell- tale accumulations weld cracks, misaligned

metal enclosures and media damages.

INFO INFO

Page 2: Visiolite Manuale English Version PDF

BWF FTI Spa Sede legale I-21042 Caronno Pertusella (Va) I-21045 Milano vicolo Maria Bianchi 119 via A. Sangiorgio 12 Tel. +39 02.96451722 R.E.A. 291755 Fax. +39 02.96451726 C.F. / P. IVA e Reg. Imp. Mi www.bwf-fti.it – [email protected] 00730590155

Main steps to use Visiolite in the bag filter:

1. switch fan to 30% of its flow capacity

2. stop cleaning system (e.g. air pulse jet cleaning)

3. add Visiolite Powder in the pipe upstream the bag filter, as far as

possible from the bag filter itself to allow the right distribution in the

gas flow

4. dose 2 kg of product per minute

5. wait for 10 minutes with fan on

6. stop fan and check the filter using the monochromatic light

INFO INFO