Vipac Engineers & Scientists
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
70Q-18-0520-TRP-8550198-1
14 January 2019
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 2 of 46
NOTE: This is a controlled document within the document control system. If revised, it must be marked SUPERSEDED and returned to
the Vipac QA Representative. This document contains commercial, conceptual and engineering information that is proprietary to Vipac
Engineers & Scientists Ltd. We specifically state that inclusion of this information does not grant the Client any license to use the
information without Vipac’s written permission. We further require that the information not be divulged to a third party without our written
consent
Report Title: Noise Impact Assessment
Job Title: Gainsborough Greens – Stage 7.3
DOCUMENT NO: 70Q-18-0520-TRP-8550198-1 REPORT CODE: TRP
PREPARED FOR: PREPARED BY:
Mirvac Pacific Pty Ltd Vipac Engineers and Scientists Limited
Level 17, 123 Eagle Street Level 2, 146 Leichhardt Street,
Brisbane, Queensland, 4000, Australia Spring Hill, QLD 4000,
Australia
CONTACT: Belinda Ryan
Tel: 07 38595808 Tel: +61 7 3377 0400
Fax: 07 3859 5975 Fax: +61 7 3377 0499
PREPARED BY:
Author: Date: 14 Jan 2019
Arnold Mafu
Project Engineer
REVIEWED BY:
Reviewer: Date: 14 Jan 2019
Jackson Yu
Senior Acoustic Consultant, Team Leader
AUTHORISED BY:
Date:14 Jan 2019
Jackson Yu
Senior Acoustic Consultant, Team Leader
REVISION HISTORY
Revision No. Date Issued Reason/Comments
0 21/12/2018 Initial Issue
1 14/01/2019 Revised Issue
2
DISTRIBUTION
Copy No.______ Location
1 Project
2 Client (PDF Format) Uncontrolled Copy
3
KEYWORDS:
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 3 of 46
TABLE OF CONTENTS
1 INTRODUCTION ..............................................................................................................................4
2 PROPOSED DEVELOPMENT AND SURROUNDING AREA ........................................................4
3 EXISTING NOISE ENVIRONMENT .................................................................................................5
3.1 Attended Measurements ...................................................................................................................6
3.2 Unattended Measurements ..............................................................................................................7
4 NOISE CRITERIA .............................................................................................................................7
4.1 State Development Assessment Provisions .....................................................................................7
4.2 Queensland Development Code MP4.4 ...........................................................................................8
5 NOISE IMPACT ASSESSMENT ......................................................................................................9
5.1 Modelling Methodology and Rail Data ..............................................................................................9
5.2 Noise Model Calibration ....................................................................................................................9
5.3 Predicted Noise Levels .................................................................................................................. 10
5.3.1 Predicted Outdoor Space noise Levels With Existing Acoustic Barrier............................... 10
5.3.2 Predicted Façade-Corrected noise Levels with Existing Acoustic Barrier .......................... 10
6 BUILDING CONSTRUCTION ACOUSTIC REQUIREMENTS ..................................................... 10
6.1 Glazing Requirements ................................................................................................................... 10
6.2 External Wall Requirements .......................................................................................................... 11
6.3 Ceiling/Roof Requirements ............................................................................................................ 11
6.4 Ventilation Requirements ............................................................................................................... 12
7 CONCLUSION AND RECOMMENDATIONS ............................................................................... 12
Site Layout ................................................................................................... 13
Noise Measurement Results and Weather observations ............................. 15
State Planning policy Interactive Mapping System ...................................... 21
Gold Coast Line Time Table ........................................................................ 22
SDAP Predicted Rail Noise Levels .............................................................. 24
Predicted Rail Noise Levels and MP4.4 Categories .................................... 30
Noise Contour Maps..................................................................................... 40
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 4 of 46
1 INTRODUCTION
Vipac Engineers & Scientists Ltd (Vipac) was commissioned by Mirvac Pacific Pty Ltd to carry out a rail noise
impact assessment for Stage 7.3 of the proposed Gainsborough Greens residential development located on
Gainsborough Drive/Kosciuszko Circuit, Pimpama (Lot 3001 on SP291537). This rail noise assessment
includes the following:
Description of the development;
Discussion of the applicable noise criteria;
Prediction of rail noise levels for the lots in the proposed development;
Assessment of predicted rail noise levels against applicable noise criteria;
Discussion of noise mitigation if required; and
Recommendations and conclusion.
2 PROPOSED DEVELOPMENT AND SURROUNDING AREA
The proposed residential development is located on Gainsborough Drive/Kosciuszko Circuit, Pimpama in an
area zoned Medium Density Residential under the City of Gold Coast City Plan. The surrounding land uses
are as follows:
North – Existing detached residential dwellings
East – Vacant Land;
South – Existing detached residential dwellings
West – 1.8m acoustic barrier along the top half the site boundary, the Brisbane-Gold Coast Railway
line and the Old Pacific Highway.
The location of the proposed development is presented in Figure 2-1. Architectural drawings are presented in
Appendix A.
Figure 2-1: Proposed Site Location (City of Gold Coast City Plan)
Site Location
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 5 of 46
The proposed development comprises of 194 lots and the site layout is presented in Figure 2-2.
Figure 2-2: Site Layout and Existing 1.8m Acoustic Barrier
3 EXISTING NOISE ENVIRONMENT
Attended and unattended noise measurements were conducted at the development site between 19th
November 2018 and 22nd November 2018 using 4 environmental noise loggers and a sound level meter. The
noise loggers were used to record noise levels at 15 minute intervals with the microphone set up in free field at
1.5m above ground level. All monitors were calibrated before and after the measurements and no significant
drift was noted (<0.5 dB). A list of the equipment used is presented in Table 3-1.
Table 3-1: Summary of Measurement Equipment
Instrument Serial Number Last Calibration Date at the time of
measurement Attended Measurements
Bruel & Kjær Type 2270 SLM 3006707 20th July 2018
Ono Sokki SC-2120 Sound Calibrator 35100926 29th January 2018 Unattended Measurements
RION NL-21 01277353 17th July 2018
RION NL-21 00776884 25th January 2018
RION NL-21 00776884 23rd August 2017
Larson Davis 831 2057 1st March 2017
Existing 1.8m
Acoustic
Barrier
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 6 of 46
The measurements were conducted in general accordance with Australian Standard AS 1055:1997 –
“Acoustics – Description and measurement of environmental noise”. Further information on the
instrumentation, measurement details, measurement results and weather data for the monitoring period are
presented in Appendix B. Weather conditions were fine during the noise monitoring, with some rainfall on the
last day upon the noise logger retrieval. This data has been excluded from our monitoring results.
The environmental noise loggers were installed near the site boundary to the west of the site as shown in
Figure 3-1.
Figure 3-1: Noise Monitoring Locations
The terrain of the development site is higher than that of the train line, and as a result, the trains were only
partially visible when passing through. The day time noise environmental noise during the site visit on 19 th
November was bird and insect noises, and the occasional train and traffic.
3.1 ATTENDED MEASUREMENTS
Attended measurements were conducted in close proximity to Location 3 for rail noise whilst on site on the
19th of November 2018. Two passenger trains passed by between 2:30pm and 2:45pm and the measurement
results were recorded. The attended and unattended measurements for that time period for the train passbys
are presented in Table 3-2.
Location 1
(353)
Location 2
(2057)
Location 3
(884)
Location 4
(886)
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 7 of 46
Table 3-2: Measured Maximum Train Noise Levels Recorded between 2:30pm and 2:45pm at Location 3
Measurement Noise Descriptor Measured Noise Level
dB(A)
Attended LAmax
64.7
Unattended 66.0
As expected, the results from the attended and unattended results for that time period generally agree with
each other, with a difference of less than 2dB.
3.2 UNATTENDED MEASUREMENTS
The single event maximum (SEM) LAmax was calculated based on the arithmetic average of maximum levels of
the highest 15 events over the entire noise monitoring period for Location 3 and Location 4. The Location 1
and Location 2 noise data was not used due to the presence of the acoustic barrier. The LAeq,24hr was derived
from the entire noise monitoring period as well and the results are presented in Table 3-3 below.
Table 3-3: Measured Noise Levels for Rail Noise Model Calibration
Monitoring Location LAmax LAeq,24hr
dB(A)
Location 3 75.0 52.8
Location 4 76.1 51.6
4 NOISE CRITERIA
4.1 STATE DEVELOPMENT ASSESSMENT PROVISIONS
The Department of State Development Infrastructure, Local Government and Planning’s “State Development Assessment Provisions” (SDAP) (version 2.1 published on 1st August 2017) has been adopted to assess rail
noise impacts on the development. The development has been assessed according to noise limits for
residences in a transport corridor as it is located adjacent to the Gold Coast line to the west of the
development. Noise limits from the relevant sections of SDAP’s State Code 2 are presented in Table 4-1.
Table 4-1: SDAP State Code 2 Noise Criteria
Performance Outcomes Acceptable Outcomes
Accommodation activities adjacent to a railway or type 2 multimodal corridor
PO24 Development involving an
accommodation activity or land for a future
accommodation activity minimises noise
intrusion from a railway or type 2 multi-
modal corridor in habitable rooms.
AO24.1 A noise barrier or earth mound is provided which is designed, sited
and constructed:
1. To meet the following external noise criteria at all facades of the
building envelope:
a. ≤ 65 dB(A) Leq (24 hour) façade corrected
b. ≤ 87 dB(A) (single event maximum sound pressure level)
façade corrected
2. in accordance with the Civil Engineering Technical Requirement –
CIVIL-SR-014 Design of noise barriers adjacent to railways,
Queensland Rail, 2011.
If the building envelope is unknown, the deemed-to-comply setback distances for
buildings stipulated by the local planning instrument or relevant building regulations
should be used.
In some instances, the design of noise barriers and mounds to achieve the noise
criteria above the ground floor may not be reasonable or practicable. In these
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 8 of 46
Performance Outcomes Acceptable Outcomes
instances, any relaxation of the criteria is at the discretion of the Department of
Transport and Main Roads.
Statutory Note: Noise levels from railways or type 2 multi-modal corridors are to be
measured in accordance with AS1055.1–1997 Acoustics – Description and
measurement of environmental noise.
Habitable rooms of residential buildings located within a transport noise corridor
must comply with the Queensland Development Code MP4.4 Buildings in a
transport noise corridor, Queensland Government, 2010. Transport noise corridors
are mapped on the Department of Infrastructure, Local Government and Planning’s State Planning Policy Interactive Mapping System.
PO25 Development involving an
accommodation activity or land for a future
accommodation activity minimises noise
intrusion from a railway or type 2 multi-
modal corridor in outdoor spaces for passive
recreation.
AO25.1 A noise barrier or earth mound is provided which is designed, sited
and constructed:
1. To meet the following external noise criteria in outdoor spaces for
passive recreation:
a. ≤ 62 dB(A) Leq (24 hour) free field
b. ≤ 84 dB(A) (single event maximum sound pressure level) free
field
2. in accordance with the Civil Engineering Technical Requirement –
CIVIL-SR-014 Design of noise barriers adjacent to railways,
Queensland Rail, 2011..
4.2 QUEENSLAND DEVELOPMENT CODE MP4.4
The Queensland Development Code MP4.4 document specifies external building construction requirements
based on the external rail noise levels to achieve acceptable indoor noise levels. The rail noise level
categories, as specified in Schedule 3 of MP4.4, are given in Table 4-2. The required building construction
acoustic ratings for each noise category are also listed in Table 4-2. The MP4.4 rail noise contour map as per
Queensland’s State Planning Policy is presented in Appendix C.
Table 4-2: MP4.4 Rail Noise Category Levels and Required Building Construction Acoustic Ratings
Noise Category
Single Event Maximum Noise
LAmax (façade corrected)
Required Acoustic Ratings (Rw) Glazing and Frames
External Walls Ceiling and
Roofs
Room Façade
Glazing Area
1.8m2
Room Façade
Glazing
< 1.8m2
Category 4 85dB(A) Rw 43 Rw 43 Rw 52 Rw 45
Category 3 80–84 dB(A) Rw 38 Rw 35 Rw 47 Rw 41
Category 2 75-79 dB(A) Rw 35 Rw 32 Rw 41 Rw 38
Category 1 70-74 dB(A) Rw 27 Rw 24 Rw 35 Rw 35
Category 0 69 dB(A) None None None None
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 9 of 46
5 NOISE IMPACT ASSESSMENT
A noise impact assessment has been conducted using SoundPLAN noise modelling software. The following
are discussed in this section:
Modelling methodology and rail movement data;
Model calibration; and
Predicted rail noise levels and MP4.4 Categories.
5.1 MODELLING METHODOLOGY AND RAIL DATA
Rail noise calculations were carried out using SoundPLAN 7.0 noise modelling software. The data and
assumptions used in rail modelling are presented in Table 5-1.
Table 5-1: Data and Assumptions Used in Rail Noise Modelling
Parameter Data
Future Residence Receiver Heights
Ground Floor: 1.8m above ground level as obtained from terrain data (façade corrected)
Ground Floor: 1.5m above ground level as obtained from terrain data (outdoor spaces for passive recreation)
First Floor: 4.6m above ground level as obtained from terrain data (assuming height of storeys as 2.8m)
Terrain Data Data from Mirvac Pacific Pty Ltd, “BRJD4595-073-135-1-EXT.dwg”, received
11/12/2018
Lot Layout Data from Mirvac Pacific Pty Ltd, “BRJD4595-000-315-290 LOTCALCS-EXT.dwg”,
received 13/12/2019
Calculation Method Nordic Rail Prediction (Kilde Rep. 130)
Façade Correction +2.5 dB(A)
Rail Track Head Height 0.6m above ground
Existing Mitigation 1.8m Acoustic Barrier adjacent the western site boundary as shown in Figure 2-2
The rail movements along the Gold Coast Line were derived from the Queensland Rail (QR) and Trankslink
timetable. Table 5-2 presents the summary of the estimated daily train movements that passed by the site
during the week from 19th November 2018 and 22nd November 2018. Appendix D contains the QR timetable
with the train movement information used in this assessment.
Table 5-2: Train Passbys
Rail Line Number Of Estimated Trains (Daily)
Gold Coast 86
5.2 NOISE MODEL CALIBRATION
The measured SEM LAmax noise levels at Location 3 and Location 4 as presented in Table 3-3 were used to
calibrate the noise model prior to modelling the rail noise impacts to the development. The model calibration
results are presented in Table 5-3.
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 10 of 46
Table 5-3: Noise Model Validation Results
Location Source LAeq,24hr dB(A) Difference dB(A) LAmax Difference
dB(A)
Location 3 Model Predicted 52.4
0.4 75.1
0.1 Measured 52.8 75.0
Location 4 Model Predicted 51.1
0.5 77.1
1.0 Measured 51.6 76.1
5.3 PREDICTED NOISE LEVELS
5.3.1 PREDICTED OUTDOOR SPACE NOISE LEVELS WITH EXISTING ACOUSTIC BARRIER
The predicted noise levels for the outdoor space areas are tabulated in Appendix E. Noise modelling results
show the free-field rail noise levels for lots in the development range between LAeq,24hr 33 dB(A) and 48 dB(A).
For LAmax, free-field rail noise levels for lots in the development range between 51 dB(A) and 70 dB(A). Both
free-field LAeq,24hr and LAmax rail noise levels are predicted to comply with the SDAP private open space criteria.
Noise contour maps are presented in Appendix G.
5.3.2 PREDICTED FAÇADE-CORRECTED NOISE LEVELS WITH EXISTING ACOUSTIC BARRIER
The predicted external noise levels at the building façades are tabulated in Appendix E. Noise modelling
results show the façade-corrected LAeq,24hr noise levels range between 35 dB(A) and 50 dB(A). The façade
corrected LAmax noise levels range between 54 dB(A) and 73 dB(A). Both façade-corrected LAeq,24hr and LAmax
rail noise levels are predicted to comply with the SDAP external noise criteria at all building façades. Noise
contour maps are presented in Appendix G.
6 BUILDING CONSTRUCTION ACOUSTIC REQUIREMENTS
The predicted façade-corrected corrected noise levels and corresponding MP4.4 Rail Noise Categories are
tabulated in Appendix F. The rail noise categories range from 0 to 1 for the ground floor and 0 to 2 for the first
floor. The noise contour maps are presented in Appendix G.
Consequently, building construction should be designed to achieve the ratings specified in the MP4.4
document, as presented in Table 4-2. Glazing, external wall, ceiling/roof and ventilation requirements are
specified in Sections 6.1 to 6.4.
6.1 GLAZING REQUIREMENTS
Glazing requirements were determined to achieve acceptable indoor rail noise levels, as per MP4.4. Glazing
requirements are specified in Table 6-1.
Table 6-1: Required Glazing Ratings for Future Residences
Floor Lots
Minimum Required Glazing and Frames Acoustic Rating (Rw)
Room Façade Glazing Area ≥ 1.8m2
Room Façade Glazing Area <1.8m2
Ground
1669, 1670 1671, 1672,
1717, 1718, 1719, 1720,
1721, 1722, 1723
27 24
First
1667, 1668, 1669, 1672,
1673, 1674, 1722, 1723,
1724
27 24
1670, 1671, 1717, 1718,
1719, 1720, 1721 35 32
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 11 of 46
Typical Rw values for different glazing thicknesses are presented in Table 6-2.
Table 6-2: Typical Rw Values for Different Glazing Thicknesses
Rw Glazing Thickness
20 3 mm
25 4.5/5 mm
31 6.38/6.76mm laminate
35 10.38 mm laminate
40 Double glazed (>75mm cavity)
It is required that the Rw performance ratings of the glazing systems (windows and frames) be certified by the
supplier prior to installation. Glazing and frame certificates will be required for building certification. Where
glazing system requirements are considered high, the design or glazed surface area can be reduced to
minimise the acoustic rating required.
6.2 EXTERNAL WALL REQUIREMENTS
The external wall construction options shown in Table 6-3 are example forms of construction to achieve
acceptable indoor rail noise levels. Alternative external wall constructions that achieve the specified acoustic
ratings may be adopted.
Table 6-3: Required External Wall Construction Specifications for Future Residences
Floor
Required
Acoustic
Rating (Rw)
Lots
Construction options to achieve the required rating
Ground 35
1669, 1670 1671,
1672, 1717, 1718,
1719, 1720, 1721,
1722, 1723
External Wall – Brick
Single leaf of brick masonry (minimum 110mm)
70mm timber studs at 600 mm centres
1 X 10mm plasterboard
External Wall –
Lightweight
Fibre cement cladding (minimum 6.5mm)
70mm timber studs at 600 mm centres
1 X 10mm plasterboard
First
35 1667, 1668, 1669, 1672, 1673, 1674, 1722, 1723, 1724
External Wall – Brick
Single leaf of brick masonry (minimum 110mm)
70mm timber studs at 600 mm centres
1 X 10mm plasterboard
External Wall –
Lightweight
Fibre cement cladding (minimum 6.5mm)
70mm timber studs at 600 mm centres
1 X 10mm plasterboard
41
1670, 1671, 1717,
1718, 1719, 1720,
1721
External Wall – Brick
Brick veneer (minimum 70mm)
70mm timber studs at 600 mm centres
1 X 10mm plasterboard
R2.5 Batts insulation
6.3 CEILING/ROOF REQUIREMENTS
The ceiling/roof construction specifications Table 6-4 are example forms of construction to achieve acceptable
indoor rail noise levels. Alternative ceiling/roof constructions that achieve the specified acoustic rating may be
adopted.
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 12 of 46
Table 6-4: Required Ceiling / Roof Construction Specifications for Future Residences
Floor Lots
Required
Acoustic Rating
(Rw)
Construction to achieve the required rating
First
1670, 1671, 1717,
1718, 1719, 1720,
1721
38
Concrete tiles / sheet metal
R3.0 Batts insulation
10mm acoustic rated plasterboard
6.4 VENTILATION REQUIREMENTS
Acceptable indoor noise levels according to MP4.4 can be achieved: however, for the habitable rooms of
future residences on Lots where the MP4.4 rail noise categories are 1 or greater, doors and windows must be
closed. Alternative ventilation may include air-conditioning, borrowed ventilation, mechanical assisted
ventilation or other suitable methods.
7 CONCLUSION AND RECOMMENDATIONS
Vipac Engineers & Scientists Ltd (Vipac) has completed a rail noise impact assessment for Stage 7.3 of the
proposed Gainsborough Greens residential development located on Gainsborough Drive/Kosciuszko Circuit,
Pimpama (Lot 3001 on SP291537).
Rail noise levels have been predicted to comply with the State Development Assessment Noise Provisions
(SDAP) State Code 2 noise limits for all lots within the proposed development.
The rail noise QDC MP4.4 categories range from 0 to 1 for the ground floor and 0 to 2 for the first floor. As a
result, the building construction requirements to achieve compliance are as follows:
Selection of glazing as presented in Table 6-1;
Construction of external walls as presented in Table 6-3; and
Construction of ceilings and roofs as presented in Table 6-4.
For habitable rooms of future residences on Lots where the MP4.4 Rail Noise Category is 1 or greater, doors
and windows must be closed to achieve acceptable indoor noise levels. Under these conditions, alternative
ventilation will be required in affected rooms. Alternative ventilation may include air-conditioning, borrowed
ventilation, mechanically assisted ventilation or other suitable methods.
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 13 of 46
SITE LAYOUT
This page has been left blank.
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 14 of 46
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 15 of 46
NOISE MEASUREMENT RESULTS AND WEATHER OBSERVATIONS
Table B-1 Noise Monitoring Details
Parameter Location 1 Location 2 Location 3 Location 4
Microphone Height 1.5m
Microphone Orientation Pointing vertically upwards
SLM Time Weighting Fast
SLM Frequency Weighting A
Measurement Interval Period 15 min intervals
Logger 01277353 2057 00776884 00776886
Measurement weather Fine, steady breeze. Light rain on final day.
Date of measurement 19th November 2018 to 22nd November 2018
Observations Train noise audible, personnel on-site, some traffic noise audible. Bird and insect
noises. Existing acoustic barrier along the top half of the western site boundary.
Table B-2 Noise Monitoring Results (Free Field)
Noise Descriptor Location 1 Location 2 Location 3 Location 4
Noise Level (dB(A))
Average LA10, 18hr (6am to 12am)
53.2 50.1 50.2 49.0
Average LA90, 8hr (10pm to 6am)
41.4 41.6 43.2 42.7
LAmax (24hr) 84.1 78.0 79.2 78.1
LAmax,Night (10pm to 7am) 75.5 73.4 74.0 72.9
Average LAeq,Avg Day (7am to 6pm)
53.8 50.5 51.3 50.1
Average LAeq,Avg Evening (6pm to 10pm)
54.9 49.2 54.2 53.0
Average LAeq,Avg Night (10pm to 7am)
51.5 47.8 50.8 49.6
Average LAeq,Max 1hr Day
(7am to 6pm) 56.4 52.6 54.3 53.1
Average LAeq,Max 1hr Evening
(6pm to 10pm) 57.2 50.4 56.8 55.6
Average LAeq,Max 1hr Night
(10pm to 7am) 56.1 51.6 54.9 53.7
Average LA90 (7am to 6pm)
42.1 42.4 43.6 43.1
Average LA90 (6pm to 10pm)
45.6 43.1 45.1 44.6
Average LA90 (10pm to 7am)
41.7 41.8 43.4 42.9
RBL Day 40.6 40.8 42.0 41.5
RBL Evening 41.1 40.2 41.5 41.0
RBL Night 36.1 37.3 38.1 37.6
LAeq,24hr 50.5 53.6 52.8 51.6
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 16 of 46
Figure B-1: Location 1 Noise Measurement Results
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 17 of 46
Figure B-2: Location 2 Noise Measurement Results
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 18 of 46
Figure B-3: Location 3 Noise Measurement Results
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 19 of 46
Figure B-4: Location 4 Noise Measurement Results
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 20 of 46
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 21 of 46
STATE PLANNING POLICY INTERACTIVE MAPPING SYSTEM
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 22 of 46
GOLD COAST LINE TIME TABLE
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 23 of 46
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 24 of 46
SDAP PREDICTED RAIL NOISE LEVELS
Table E-1: SDAP Rail Noise Level Predictions
Lot No
Free-field Façade Corrected
LAeq 24hr LAmax LAeq 24hr LAmax
dB(A)
1531 39.5 61.4 42 63.9
1532 40.1 62 42.6 64.5
1533 40.8 63.1 43.3 65.6
1534 41.5 64.1 44 66.6
1535 41.4 64 43.9 66.5
1536 41.5 64.2 44 66.7
1537 41.1 63.7 43.6 66.2
1538 41 63.3 43.5 65.8
1539 41.2 63.5 43.7 66
1540 41 62.9 43.5 65.4
1541 39.4 60.8 41.9 63.3
1542 39.4 61.1 41.9 63.6
1543 39.5 61.1 42 63.6
1544 39.2 61.1 41.7 63.6
1545 39.2 60.9 41.7 63.4
1546 38.9 60.4 41.4 62.9
1547 38.8 60.4 41.3 62.9
1548 38.3 59.5 40.8 62
1549 37.2 58 39.7 60.5
1550 37.3 58.1 39.8 60.6
1551 37.4 58.3 39.9 60.8
1552 37.6 58.5 40.1 61
1553 37.7 58.7 40.2 61.2
1554 37.8 58.9 40.3 61.4
1555 37.9 58.9 40.4 61.4
1556 38 59.1 40.5 61.6
1557 37.9 58.5 40.4 61
1558 37.9 58.4 40.4 60.9
1559 37.7 57.4 40.2 59.9
1560 38.5 58.7 41 61.2
1561 39.1 59.4 41.6 61.9
1562 39.8 60.4 42.3 62.9
1563 40.5 61 43 63.5
1564 40.3 60.2 42.8 62.7
1565 39.8 60 42.3 62.5
1566 39.1 59.1 41.6 61.6
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 25 of 46
Lot No
Free-field Façade Corrected
LAeq 24hr LAmax LAeq 24hr LAmax
dB(A)
1567 38.6 58.6 41.1 61.1
1568 38 57.6 40.5 60.1
1569 37.5 56.9 40 59.4
1570 37.2 57 39.7 59.5
1571 36.6 55.9 39.1 58.4
1572 36.5 55.8 39 58.3
1573 36.5 56.2 39 58.7
1574 36.7 56.8 39.2 59.3
1575 36.7 56.8 39.2 59.3
1576 36.7 56.8 39.2 59.3
1577 36.6 56.8 39.1 59.3
1578 36.7 57.3 39.2 59.8
1579 36.6 57.1 39.1 59.6
1580 36.5 57.1 39 59.6
1581 36.4 57 38.9 59.5
1582 36.4 57 38.9 59.5
1583 36.2 56.9 38.7 59.4
1584 35 55.6 37.5 58.1
1585 34.8 53.3 37.3 55.8
1586 34.5 52.9 37 55.4
1587 34.3 52.7 36.8 55.2
1588 34 52.5 36.5 55
1589 33.8 52.2 36.3 54.7
1590 33.6 52 36.1 54.5
1591 33.4 51.8 35.9 54.3
1592 33.2 51.6 35.7 54.1
1593 32.9 51.3 35.4 53.8
1594 33.4 52.7 35.9 55.2
1595 33.7 52.8 36.2 55.3
1596 34 53 36.5 55.5
1597 34.2 53.1 36.7 55.6
1598 34.4 53.3 36.9 55.8
1599 34.6 53.4 37.1 55.9
1600 34.9 53.5 37.4 56
1601 35.1 53.6 37.6 56.1
1602 35.4 53.7 37.9 56.2
1603 35.4 53.8 37.9 56.3
1604 35 53.6 37.5 56.1
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 26 of 46
Lot No
Free-field Façade Corrected
LAeq 24hr LAmax LAeq 24hr LAmax
dB(A)
1605 34.7 53.5 37.2 56
1606 34.4 53.3 36.9 55.8
1607 34.1 53.1 36.6 55.6
1608 33.9 52.9 36.4 55.4
1609 33.5 52.6 36 55.1
1610 33.2 52.3 35.7 54.8
1611 32.5 54.5 35 57
1612 32.6 51.4 35.1 53.9
1613 32.6 51.5 35.1 54
1614 32.5 51.6 35 54.1
1615 32.6 51.7 35.1 54.2
1616 32.6 51.7 35.1 54.2
1617 32.9 52.8 35.4 55.3
1618 33 53.1 35.5 55.6
1619 33.1 53.4 35.6 55.9
1620 33.2 53.5 35.7 56
1621 33.7 53.8 36.2 56.3
1622 33.8 54 36.3 56.5
1623 33.6 54.3 36.1 56.8
1624 33.8 54.6 36.3 57.1
1625 34.1 54.9 36.6 57.4
1626 34.4 55.1 36.9 57.6
1627 34.7 55.3 37.2 57.8
1628 34.9 55.4 37.4 57.9
1629 35 55.5 37.5 58
1630 35.2 55.6 37.7 58.1
1631 35.8 56.3 38.3 58.8
1632 35.9 56 38.4 58.5
1633 35.6 54.9 38.1 57.4
1634 35.6 54.7 38.1 57.2
1635 35.1 54.8 37.6 57.3
1636 34.8 54.7 37.3 57.2
1637 34.7 54.6 37.2 57.1
1638 34.5 54.6 37 57.1
1639 34.3 54.4 36.8 56.9
1640 34.1 54.2 36.6 56.7
1641 33.8 54 36.3 56.5
1642 33.7 53.6 36.2 56.1
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 27 of 46
Lot No
Free-field Façade Corrected
LAeq 24hr LAmax LAeq 24hr LAmax
dB(A)
1643 33.6 53.1 36.1 55.6
1644 33.9 53.4 36.4 55.9
1645 34.1 53.6 36.6 56.1
1646 34.3 53.8 36.8 56.3
1647 34.5 53.9 37 56.4
1648 34.8 54.2 37.3 56.7
1649 35.1 54.5 37.6 57
1650 35.6 54.8 38.1 57.3
1651 35.7 54.9 38.2 57.4
1652 37 55.8 39.5 58.3
1653 37 57.1 39.5 59.6
1654 36.8 55.5 39.3 58
1655 36.9 55.8 39.4 58.3
1656 36.6 56 39.1 58.5
1657 36.8 56.4 39.3 58.9
1658 36.8 56.8 39.3 59.3
1659 36.9 57.2 39.4 59.7
1660 37.5 58.4 40 60.9
1661 38.6 60.1 41.1 62.6
1662 39.6 61.1 42.1 63.6
1663 40.3 61.9 42.8 64.4
1664 41 66.5 43.5 69
1665 41.6 64.7 44.1 67.2
1666 42.5 64.3 45 66.8
1667 43.5 65.2 46 67.7
1668 44.7 66.5 47.2 69.0
1669 45.9 67.9 48.4 70.4
1670 47.2 69.4 49.7 72.9
1671 47.8 70.1 50.3 72.6
1672 45.6 66.4 48.1 68.9
1673 44.2 65.2 46.7 67.7
1674 43.4 64.4 45.9 66.9
1675 42.3 63.4 44.8 65.9
1676 41.6 62.9 44.1 65.4
1677 40.8 62 43.3 64.5
1678 40.4 61.6 42.9 64.1
1679 39.4 60.5 41.9 63
1680 38.6 59.6 41.1 62.1
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 28 of 46
Lot No
Free-field Façade Corrected
LAeq 24hr LAmax LAeq 24hr LAmax
dB(A)
1681 37.8 58.7 40.3 61.2
1682 38 58.4 40.5 60.9
1683 38 58.2 40.5 60.7
1684 38.1 58.3 40.6 60.8
1685 38.1 57.9 40.6 60.4
1686 38 57.6 40.5 60.1
1687 37.9 56.9 40.4 59.4
1688 37.8 59.3 40.3 61.8
1689 37.7 56.6 40.2 59.1
1690 37.8 56.8 40.3 59.3
1691 39.2 58.4 41.7 60.9
1692 39.2 58.1 41.7 60.6
1693 39.1 57.5 41.6 60
1694 39.2 58.2 41.7 60.7
1695 39.3 58.5 41.8 61
1696 39.2 58.8 41.7 61.3
1697 39.3 59.3 41.8 61.8
1698 39.3 59.3 41.8 61.8
1699 39.4 59.8 41.9 62.3
1700 41.3 61.6 43.8 64.1
1701 41 61.1 43.5 63.6
1702 40.9 60.7 43.4 63.2
1703 40.7 60.1 43.2 62.6
1704 40.7 61 43.2 63.5
1705 40.7 62.4 43.2 64.9
1706 40.4 59.1 42.9 61.6
1707 40.6 59.1 43.1 61.6
1708 40.4 58.6 42.9 61.1
1709 42.7 61.4 45.2 63.9
1710 42.6 61.9 45.1 64.4
1711 42.6 62.2 45.1 64.7
1712 42.8 62.9 45.3 65.4
1713 42.8 62.8 45.3 65.3
1714 43.2 63.6 45.7 66.1
1715 43.4 69.2 45.9 71.7
1716 43.6 65.6 46.1 68.1
1717 46.9 68.5 49.4 71
1718 46.8 68.5 49.3 71
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 29 of 46
Lot No
Free-field Façade Corrected
LAeq 24hr LAmax LAeq 24hr LAmax
dB(A)
1719 46.4 68.1 48.9 70.6
1720 46.4 68.4 48.9 70.9
1721 46 67.9 48.5 70.4
1722 45.4 67 47.9 69.5
1723 45.5 66.5 48 69
1724 44.6 64.2 47.1 66.7
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 30 of 46
PREDICTED RAIL NOISE LEVELS AND MP4.4 CATEGORIES
Table F-1: Predicted Façade Corrected Rail Noise Levels and Construction Categories
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
1531
Ground 63.9 0
First 66.2 0
1532
Ground 64.5 0
First 67.8 0
1533
Ground 65.6 0
First 68 0
1534
Ground 66.6 0
First 69.3 0
1535
Ground 66.5 0
First 68.9 0
1536
Ground 66.7 0
First 68.6 0
1537
Ground 66.2 0
First 67.8 0
1538
Ground 65.8 0
First 67.4 0
1539
Ground 66 0
First 67.4 0
1540
Ground 65.4 0
First 66.8 0
1541
Ground 63.7 0
First 64.4 0
1542
Ground 63.6 0
First 65.3 0
1543
Ground 63.6 0
First 64.9 0
1544
Ground 63.6 0
First 64.9 0
1545
Ground 63.4 0
First 65.3 0
1546
Ground 62.9 0
First 65.3 0
1547
Ground 62.9 0
First 65.1 0
1548
Ground 62 0
First 63.9 0
1549 Ground 60.5 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 31 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
First 61.7 0
1550
Ground 60.6 0
First 61.9 0
1551
Ground 60.8 0
First 62.1 0
1552
Ground 61 0
First 62.4 0
1553
Ground 61.2 0
First 62.7 0
1554
Ground 61.4 0
First 62.9 0
1555
Ground 61.4 0
First 62.9 0
1556
Ground 61.6 0
First 63.1 0
1557
Ground 61 0
First 62.9 0
1558
Ground 60.9 0
First 62.3 0
1559
Ground 59.9 0
First 61.8 0
1560
Ground 61.2 0
First 62.7 0
1561
Ground 61.9 0
First 63.4 0
1562
Ground 62.6 0
First 64.2 0
1563
Ground 63.5 0
First 65.2 0
1564
Ground 62.7 0
First 65.2 0
1565
Ground 62.5 0
First 64 0
1566
Ground 61.6 0
First 63.1 0
1567
Ground 61.1 0
First 62.5 0
1568
Ground 60.1 0
First 61.2 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 32 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
1569 Ground 59.4 0
First 61.2 0
1570
Ground 59.5 0
First 60.5 0
1571
Ground 58.4 0
First 59.1 0
1572
Ground 58.3 0
First 59 0
1573
Ground 58.7 0
First 59.6 0
1574
Ground 59.3 0
First 60.1 0
1575
Ground 59.3 0
First 60.4 0
1576
Ground 59.3 0
First 60.6 0
1577
Ground 59.3 0
First 60.6 0
1578
Ground 59.8 0
First 61.1 0
1579
Ground 59.6 0
First 61 0
1580
Ground 59.6 0
First 60.7 0
1581
Ground 59.5 0
First 60.6 0
1582
Ground 59.5 0
First 60.6 0
1583
Ground 59.4 0
First 59.8 0
1584
Ground 56.1 0
First 57.5 0
1585
Ground 55.8 0
First 57.3 0
1586
Ground 55.4 0
First 56.9 0
1587
Ground 55.2 0
First 56.6 0
1588 Ground 55 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 33 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
First 56.6 0
1589
Ground 54.7 0
First 56.4 0
1590
Ground 54.5 0
First 56.3 0
1591
Ground 54.3 0
First 56.1 0
1592
Ground 54.1 0
First 55.9 0
1593
Ground 53.8 0
First 55.7 0
1594
Ground 55.2 0
First 56.7 0
1595
Ground 55.3 0
First 56.9 0
1596
Ground 55.5 0
First 57.1 0
1597
Ground 59.4 0
First 57.3 0
1598
Ground 55.8 0
First 57.5 0
1599
Ground 55.9 0
First 57.7 0
1600
Ground 57.5 0
First 57.7 0
1601
Ground 56.1 0
First 57.8 0
1602
Ground 56.2 0
First 58 0
1603
Ground 56.3 0
First 58.1 0
1604
Ground 56.1 0
First 57.8 0
1605
Ground 56 0
First 57.8 0
1606
Ground 55.8 0
First 57.6 0
1607
Ground 55.6 0
First 57.3 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 34 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
1608 Ground 55.4 0
First 57.1 0
1609
Ground 55.1 0
First 56.8 0
1610
Ground 54.8 0
First 56.5 0
1611
Ground 53.6 0
First 55.4 0
1612
Ground 56.5 0
First 55.7 0
1613
Ground 54 0
First 55.8 0
1614
Ground 54.1 0
First 55.9 0
1615
Ground 54.2 0
First 56 0
1616
Ground 54.2 0
First 56 0
1617
Ground 55.3 0
First 56.3 0
1618
Ground 55.6 0
First 56.5 0
1619
Ground 55.9 0
First 56.8 0
1620
Ground 56 0
First 56.9 0
1621
Ground 56.3 0
First 57.1 0
1622
Ground 56.5 0
First 57.4 0
1623
Ground 56.8 0
First 57.7 0
1624
Ground 57.1 0
First 58 0
1625
Ground 57.4 0
First 58.3 0
1626
Ground 57.6 0
First 58.6 0
1627 Ground 57.8 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 35 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
First 58.9 0
1628
Ground 57.9 0
First 59 0
1629
Ground 58 0
First 62.7 0
1630
Ground 58.1 0
First 59.3 0
1631
Ground 58.8 0
First 60.2 0
1632
Ground 58.5 0
First 60 0
1633
Ground 59.5 0
First 59.6 0
1634
Ground 57.2 0
First 59.4 0
1635
Ground 57.3 0
First 59.2 0
1636
Ground 57.2 0
First 59 0
1637
Ground 57.1 0
First 58.9 0
1638
Ground 57.1 0
First 58.8 0
1639
Ground 56.9 0
First 58.6 0
1640
Ground 56.7 0
First 58.3 0
1641
Ground 56.5 0
First 58.1 0
1642
Ground 56.1 0
First 57.7 0
1643
Ground 58.4 0
First 57.3 0
1644
Ground 55.9 0
First 57.6 0
1645
Ground 56.1 0
First 57.8 0
1646
Ground 56.3 0
First 58 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 36 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
1647 Ground 56.4 0
First 58.2 0
1648
Ground 56.7 0
First 58.5 0
1649
Ground 57 0
First 59.8 0
1650
Ground 57.3 0
First 59.3 0
1651
Ground 57.4 0
First 59.3 0
1652
Ground 58.3 0
First 60.1 0
1653
Ground 58.3 0
First 61.5 0
1654
Ground 58 0
First 60.2 0
1655
Ground 58.3 0
First 60.4 0
1656
Ground 58.5 0
First 60.9 0
1657
Ground 58.9 0
First 61.3 0
1658
Ground 59.3 0
First 61.6 0
1659
Ground 59.7 0
First 62.1 0
1660
Ground 65.2 0
First 63.3 0
1661
Ground 62.6 0
First 64.9 0
1662
Ground 63.6 0
First 65.9 0
1663
Ground 68.4 0
First 66.7 0
1664
Ground 66.7 0
First 67.4 0
1665
Ground 65.8 0
First 68.1 0
1666 Ground 66.8 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 37 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
First 69.2 0
1667
Ground 69.3 0
First 70.6 1
1668
Ground 69.1 0
First 72.3 1
1669
Ground 70.4 1
First 74.3 1
1670
Ground 71.9 1
First 77.4 2
1671
Ground 72.6 1
First 78.7 2
1672
Ground 74.4 1
First 73.1 1
1673
Ground 67.7 0
First 70.4 1
1674
Ground 66.8 0
First 69.6 1
1675
Ground 65.9 0
First 68.4 0
1676
Ground 65.4 0
First 67.5 0
1677
Ground 64.5 0
First 66.6 0
1678
Ground 64.1 0
First 66 0
1679
Ground 63 0
First 65.1 0
1680
Ground 62.1 0
First 64.2 0
1681
Ground 61.2 0
First 63.7 0
1682
Ground 60.9 0
First 63 0
1683
Ground 60.7 0
First 62.7 0
1684
Ground 60.8 0
First 62.6 0
1685
Ground 60.4 0
First 65.5 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 38 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
1686 Ground 60.1 0
First 62 0
1687
Ground 59.4 0
First 61.3 0
1688
Ground 59 0
First 61 0
1689
Ground 59.1 0
First 60.8 0
1690
Ground 59.3 0
First 61.1 0
1691
Ground 60.9 0
First 61.9 0
1692
Ground 60.5 0
First 62 0
1693
Ground 60 0
First 62.3 0
1694
Ground 60.7 0
First 62.5 0
1695
Ground 61.9 0
First 62.9 0
1696
Ground 61.3 0
First 63.3 0
1697
Ground 61.8 0
First 63.8 0
1698
Ground 61.8 0
First 64 0
1699
Ground 62.3 0
First 64.3 0
1700
Ground 64.1 0
First 66.3 0
1701
Ground 63.6 0
First 65.7 0
1702
Ground 63.2 0
First 65.4 0
1703
Ground 62.6 0
First 64.9 0
1704
Ground 62.4 0
First 64.5 0
1705 Ground 62 0
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 39 of 46
Lot No Floor LAmax
QDC MP4.4 Categories dB(A)
First 64.1 0
1706
Ground 61.6 0
First 63.7 0
1707
Ground 61.6 0
First 63.4 0
1708
Ground 61.1 0
First 63.4 0
1709
Ground 63.9 0
First 68.3 0
1710
Ground 64.4 0
First 66.1 0
1711
Ground 64.7 0
First 66.5 0
1712
Ground 65.4 0
First 67.3 0
1713
Ground 65.3 0
First 67.3 0
1714
Ground 66.1 0
First 67.7 0
1715
Ground 66.4 0
First 68.3 0
1716
Ground 66.6 0
First 68.8 0
1717
Ground 71 1
First 76.1 2
1718
Ground 71 1
First 75.9 2
1719
Ground 70.6 1
First 75.1 2
1720
Ground 70.9 1
First 75.5 2
1721
Ground 70.4 1
First 75.3 2
1722
Ground 69.5 1
First 73.4 1
1723
Ground 69.5 1
First 72.7 1
1724
Ground 66.7 0
First 69.7 1
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 40 of 46
NOISE CONTOUR MAPS
This page has been left blank.
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 41 of 46
Figure G-1: Predicted Free Field LAeq (24hr) Rail Noise Levels at Private Open Spaces of Lots (SDAP)
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 42 of 46
Figure G-2: Predicted Free Field LAmax Rail Noise Levels at Private Open Spaces of Lots (SDAP)
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 43 of 46
Figure G-3: Predicted Façade-Corrected LAeq (24hr) Rail Noise Levels at External Façade of Lots (SDAP)
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 44 of 46
Figure G-4: Predicted Façade-Corrected LAmax Rail Noise Levels at External Façade of Lots (SDAP)
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 45 of 46
Figure G-5: QDC MP4.4 Rail Noise Categories for the Ground Floor
Mirvac Pacific Pty Ltd
Gainsborough Greens – Stage 7.3
Noise Impact Assessment
14 January 2019
70Q-18-0520-TRP-8550198-1 Commercial-In-Confidence Page 46 of 46
Figure G-6: QDC MP4.4 Rail Noise Categories for the First Floor