V.I. Inspections Page 1 of 10 21:21 August 24, 2018 #1 2014 N 143rd St, Seattle. #2 Paint peeling in front steps. #3 Rot present in front entry step riser trim. #4 Gap at front porch edge needs to be sealed. #5 Vegetation in contact with house should be trimmed back. #6 Paint peeling in trim work. Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 1 of 10

21:21 August 24, 2018

#1 2014 N 143rd St, Seattle. #2 Paint peeling in front steps.

#3 Rot present in front entry step riser trim. #4 Gap at front porch edge needs to be sealed.

#5 Vegetation in contact with house should be trimmed

back.

#6 Paint peeling in trim work.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 2: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 2 of 10

21:21 August 24, 2018

#7 Paint unfinished in siding system. #8 Rain barrels need to be maintained against overflow

onto siding.

#9 Paint unfinished. #10 Fence is weathered.

#11 SE basement window pane cracked. #12 Downspouts drain too close to foundation.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 3: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 3 of 10

21:21 August 24, 2018

#13 Siding install unfinished under NE bump out. #14 Paint unfinished in sections of trim work.

#15 No handrail for basement access steps. #16 Siding seams line up vertically on lower N siding.

#17 Caulking unfinished in lower N siding. #18 Pest cage will need to be maintained from lint build

up over time.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 4: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 4 of 10

21:21 August 24, 2018

#19 Oil tank for furnace located in backyard. #20 Heavy displacement in driveway retaining wall.

#21 Soil contact at SW basement window sill. #22 Debris build up in valley system.

#23 Minor moss build up on roof surface. #24 No kick out flashing installed at lower roof connection

to siding.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 5: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 5 of 10

21:21 August 24, 2018

#25 Paint peeling in fascia system. #26 SE gutter needs to be cleaned.

#27 NE gutter is not installed. #28 Possible asbestos tape present in the living room

heat register.

#29 Stairs to second floor are very steep, normal for age

of house.

#30 Active knob and tube wiring visible in attic.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 6: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 6 of 10

21:21 August 24, 2018

#31 Minor roof debris build up in attic insulation. #32 Lower cabinet base under kitchen island partially

detached.

#33 Original sewer line should be fully sealed. #34 Cross bracing not installed where floor joist has been

cut under bathroom.

#35 Rot present in sub floor material under N end of

bathroom.

#36 Form boards still installed along SE foundation wall.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 7: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 7 of 10

21:21 August 24, 2018

#37 Frass build up in SE corner of basement crawl space

indicates past insect intrusion.

#38 Cover plate missing from furance control box, live

wiring (safety).

#39 Furnace flue partially detached from chimney. #40 Abandoned wiring around electric panel should be

removed.

#41 Minor cracks in basement floor. #42 Staining along SW foundation, visible in basement,

indicates water intrusion in wet season.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 8: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 8 of 10

21:21 August 24, 2018

#43 Garage. #44 Vegetation in contact with W wall should be removed.

#45 Open gaps between siding and framing over garage

door, water intrusion spot.

#46 Roof covered in moss, cannot inspect.

#47 Tar patchwork at garage roof connection to house. #48 Roof covered in moss, cannot inspect.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 9: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 9 of 10

21:21 August 24, 2018

#49 Rot in end pieces of roof framing in SW and NE

corners.

#50 Particle board siding has higher failure rate.

#51 Rot in sections of roof framing of garage. #52 N section of garage structure being removed.

#53 Gutters not installed. #54 Siding installed around window, higher potential for

water intrusion.

Palm-Tech Picture Album, Copyright © 1998-2018 PDmB, Inc.

Page 10: V.I. Inspections · 2018. 9. 4. · #38 Cover plate missing from furance control box, live wiring (safety). #39 Furnace flue partially detached from chimney. #40 Abandoned wiring

V.I. InspectionsPage 10 of 10

21:21 August 24, 2018

#55 Sections of particle board siding have failed. #56 Rot in roof framing along NE edge.

#57 Roof framing undersized for slope and span. #58 Cracks with displacement in W retaining wall in

garage.