Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
PUB. NO. 22-1753-01-0404 (EN)
Vertical UpflowAir HandlersWith Electric Heat
2TFB4018, 24, 30, 36A1D05, 08, 10A2TFE4025A1D05, 08, 10A
© 2004 American Standard Inc. All Rights Reserved 2 22-1753-01-0404 (EN)
Features andBenefits
OPTIONAL EQUIPMENT FOR HEATING UNITSEvaporator Defrost Control Kit All Cooling Models .................................................................................................... AY28X079 [ ]Evaporator Defrost Control Kit All Heat Pump Models ............................................................................................... AY28X084 [ ]
2TFB4 Standard Equipment• Internal mounted expansion valve kits
available
• Approved for modular or manufacturedhomes
• Factory installed service disconnect
• Internally enhanced finned coil tubing
• Primary and secondary drainconnections
• Optional extended warranties
• Five year limited parts warranty
2TFE3 Standard Equipment• Factory installed electric heaters
• Expansion valve refrigerant control
• Factory installed service disconnect
• Internally enhanced finned coil tubing
• Primary and secondary drainconnections
• Approved for modular or manufacturedhomes
• Optional extended warranties
• Five year limited parts warranty
• Shipped in vertical upflow, bottomreturn with front access & convertible tovertical upflow front return
• Tight cabinet - low leakage by design
• Attractive enamel finish
• R 4.2 – 1" insulation
• Exclusive easy clean coil and drain pan
• Easy to remove filters and blowers foreasy cleaning and replacement
• Filter rack with throwaway filter
• Easy access electrical controls andhook-up
• 200/230 volt primary and 24 voltsecondary transformer
• Built-in indoor fan delay function forincreased efficiency. No kit required.
• Multi-speed blower
• Direct drive motor
• Factory installed electric heaters
• AccuTron™ refrigerant control
• Shipped in vertical upflow, bottomreturn with front access & convertible tovertical upflow front return
• Variable speed ECM motor
• Enhanced Comfort-R™
• Soft start – cycle-on speed is rampedup gradually to reduce sound and draft
• Low voltage terminal board
• Tight cabinet – low leakage by design
• Attractive enamel finish
• R 4.2 – 1" insulation
• Exclusive easy clean coil and drain pan
• Easy to remove filters and blowers foreasy cleaning and replacement
• Filter rack with throw away filter
• Easy access electrical controls andhook-up
• 200/230 volt primary and 24 voltsecondary transformer
• Built-in indoor fan delay function forincreased efficiency. No kit required.
22-1753-01-0404 (EN) 3
Contents
Features and Benefits 22TFB4 Standard Equipment 22TFE3 Standard Equipment 2Optional Equipment For Heating Units 2
General Data 42TFB4018A1D05A 42TFB4018A1D08A 42TFB4018A1D10A 42TFB4024A1D05A 52TFB4024A1D08A 52TFB4024A1D10A 52TFB4030A1D05A 62TFB4030A1D08A 62TFB4030A1D10A 62TFB4036A1D05A 72TFB4036A1D08A 72TFB4036A1D10A 72TFE3025A1D05A 82TFE3025A1D08A 82TFE3025A1D10A 8
Performance Data 9
Electrical Data 11
Refrigerant Circuit 13
Dimensions 15
4 22-1753-01-0404 (EN)
GeneralData
Product SpecificationsMODELRATED VOLTS/PH/HZ.RATINGS 1HEATER CAPACITY (Volts)HEATER CAPACITY (BTUH)POWER CONNECTIONMin. Brch. Cir. Ampacity 2Recmd-Max. Overload Protection (amps)INDOOR COIL - TypeRows - F.P.I.Face Area (sq. ft.)Tube Size (in.)Refrigerant ControlDrain Connection Size (In.) 3DUCT CONNECTIONSINDOOR FAN - TypeDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP - RPMF.L. Amps - L.R. AmpsFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)REFRIGERANT CONNECTIONSLine Size - Gas (in.)Line Size - Liquid (in.)DIMENSIONS (in.)Crated (H X W X D)UncratedWEIGHT (lbs.)Shipping - Net1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.2 Minimum Circuit Ampacity includes Blower Motor Amps3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)
2TFB4018A1D05A208/230/1/60
See O.D. Specifications240v 208v
16400 12300230v 208v27 2330 25
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/5 - 9301.0 / 1.4
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
5/81/4
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFB4018A1D08A208/230/1/60
See O.D. Specifications240v 208v
26200 19700230v 208v42 3645 40
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/5 - 9301.0 / 1.4
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
5/81/4
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFB4018A1D10A208/230/1/60
See O.D. Specifications240v 208v
32800 24600230v 208v52 4560 45
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/5 - 9301.0 / 1.4
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
5/81/4
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
22-1753-01-0404 (EN) 5
Product SpecificationsMODELRATED VOLTS/PH/HZ.RATINGS 1HEATER CAPACITY (Volts)HEATER CAPACITY (BTUH)POWER CONNECTIONMin. Brch. Cir. Ampacity 2Recmd-Max. Overload Protection (amps)INDOOR COIL - TypeRows - F.P.I.Face Area (sq. ft.)Tube Size (in.)Refrigerant ControlDrain Connection Size (In.) 3DUCT CONNECTIONSINDOOR FAN - TypeDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP - RPMF.L. Amps - L.R. AmpsFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)REFRIGERANT CONNECTIONSLine Size - Gas (in.)Line Size - Liquid (in.)DIMENSIONS (in.)Crated (H X W X D)UncratedWEIGHT (lbs.)Shipping - Net
2TFB4024A1D05A208/230/1/60
See O.D. Specifications240v 208v
16400 12300230v 208v27 2430 25
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/3 - 11031.4 / 3.3
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFB4024A1D08A208/230/1/60
See O.D. Specifications240v 208v
26200 19700230v 208v42 3745 40
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/3 - 11031.4 / 3.3
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFB4024A1D10A208/230/1/60
See O.D. Specifications240v 208v
32800 24600230v 208v52 4560 45
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/3 - 11031.4 / 3.3
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
GeneralData
1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.2 Minimum Circuit Ampacity includes Blower Motor Amps3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)
6 22-1753-01-0404 (EN)
GeneralData
Product SpecificationsMODELRATED VOLTS/PH/HZ.RATINGS 1HEATER CAPACITY (Volts)HEATER CAPACITY (BTUH)POWER CONNECTIONMin. Brch. Cir. Ampacity 2Recmd-Max. Overload Protection (amps)INDOOR COIL - TypeRows - F.P.I.Face Area (sq. ft.)Tube Size (in.)Refrigerant ControlDrain Connection Size (In.) 3DUCT CONNECTIONSINDOOR FAN - TypeDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP - RPMF.L. Amps - L.R. AmpsFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)REFRIGERANT CONNECTIONSLine Size - Gas (in.)Line Size - Liquid (in.)DIMENSIONS (in.)Crated (H X W X D)UncratedWEIGHT (lbs.)Shipping - Net
2TFB4030A1D05A208/230/1/60
See O.D. Specifications240v 208v
16400 12300230v 208v27 2430 25
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/3 - 11251.5 / 4.1
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFB4030A1D08A208/230/1/60
See O.D. Specifications240v 208v
26200 19700230v 208v42 3745 40
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/3 - 11251.5 / 4.1
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFB4030A1D10A208/230/1/60
See O.D. Specifications240v 208v
32800 24600230v 208v52 4660 50
PLATE FIN3 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 812
See Fan Performance Table1/3 - 11251.5 / 4.1
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 931 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.2 Minimum Circuit Ampacity includes Blower Motor Amps3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)
22-1753-01-0404 (EN) 7
Product SpecificationsMODELRATED VOLTS/PH/HZ.RATINGS 1HEATER CAPACITY (Volts)HEATER CAPACITY (BTUH)POWER CONNECTIONMin. Brch. Cir. Ampacity 2Recmd-Max. Overload Protection (amps)INDOOR COIL - TypeRows - F.P.I.Face Area (sq. ft.)Tube Size (in.)Refrigerant ControlDrain Connection Size (In.) 3DUCT CONNECTIONSINDOOR FAN - TypeDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP - RPMF.L. Amps - L.R. AmpsFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)REFRIGERANT CONNECTIONSLine Size - Gas (in.)Line Size - Liquid (in.)DIMENSIONS (in.)Crated (H X W X D)UncratedWEIGHT (lbs.)Shipping - Net
2TFB4036A1D08A208/230/1/60
See O.D. Specifications240v 208v
26200 19700230v 208v45 4045 40
PLATE FIN4 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
11 x 812
See Fan Performance Table3/4 - 11254.0 / 9.1
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
7/83/8
H X W X D42-1/2 x 23 x 20-3/8See Outline Drawing
120 / 98
2TFB4036A1D10A208/230/1/60
See O.D. Specifications240v 208v
32800 24600230v 208v55 4860 50
PLATE FIN4 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
11 x 812
See Fan Performance Table3/4 - 11254.0 / 9.1
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
7/83/8
H X W X D42-1/2 x 23 x 20-3/8See Outline Drawing
120 / 98
2TFB4036A1D05A208/230/1/60
See O.D. Specifications240v 208v
16400 12300230v 208v30 2730 30
PLATE FIN4 - 142.433/8
FCCV3/4 PVC SLIP
See Outline DrawingCentrifugal
11 x 812
See Fan Performance Table3/4 - 11254.0 / 9.1
YesThrowaway
1 - 18 x 20 - 1 In.Brazed
7/83/8
H X W X D42-1/2 x 23 x 20-3/8See Outline Drawing
120 / 98
GeneralData
1 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.2 Minimum Circuit Ampacity includes Blower Motor Amps3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)
8 22-1753-01-0404 (EN)
Product Specifications
GeneralData
MODELRATED VOLTS/PH/HZ.RATINGS 1HEATER CAPACITY (Volts)HEATER CAPACITY (BTUH)POWER CONNECTIONMin. Brch. Cir. Ampacity 2Recmd-Max. Overload Protection (amps)INDOOR COIL - TypeRows - F.P.I.Face Area (sq. ft.)Tube Size (in.)Refrigerant ControlDrain Connection Size (In.) 3DUCT CONNECTIONSINDOOR FAN - TypeDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HP - RPMF.L. AmpsFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)REFRIGERANT CONNECTIONSLine Size - Gas (in.)Line Size - Liquid (in.)DIMENSIONS (in.)Crated (H X W X D)UncratedWEIGHT (lbs.)Shipping - Net
2TFE3025A1D05A208/230/1/60
See O.D. Specifications240v 208v
16400 12300230v 208v30 2730 30
PLATE FIN3 - 142.433/8
NBTXV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 81
VARIABLE SPEEDSee Fan Performance Table
1/24.3Yes
Throwaway1 - 18 x 20 - 1 In.
Brazed3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFE3025A1D08A208/230/1/60
See O.D. Specifications240v 208v
16400 12300230v 208v46 4050 40
PLATE FIN3 - 142.433/8
NBTXV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 81
VARIABLE SPEEDSee Fan Performance Table
1/24.3Yes
Throwaway1 - 18 x 20 - 1 In.
Brazed3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 93
2TFE3025A1D10A208/230/1/60
See O.D. Specifications240v 208v
16400 12300230v 208v56 4960 50
PLATE FIN3 - 142.433/8
NBTXV3/4 PVC SLIP
See Outline DrawingCentrifugal
10 x 81
VARIABLE SPEEDSee Fan Performance Table
1/24.3Yes
Throwaway1 - 18 x 20 - 1 In.
Brazed3/45/16
H X W X D40-1/2 x 23 x 20-3/8See Outline Drawing
115 / 931 These Air Handlers are A.R.I certified with various Split System Air Conditioners and Heat Pumps (ARI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.2 Minimum Circuit Ampacity includes Blower Motor Amps3 3/4" Plastic Pipe (Ref.: ASTM 1785-76)
22-1753-01-0404 (EN) 9
PerformanceData
AIRFLOW PERFORMANCE2TFB4018A1D
CFM
230 VOLTS 208 VOLTS
EXTERNALSTATIC
PRESSURE(in. wg.) HI LO HI LO
0.00 920 720 815 625
0.10 880 685 785 575
0.20 830 640 735 530
0.30 775 585 675 465
0.40 705 520 600 405
0.50 630 450 535 335
0.60 550 365 445 270
0.70 455 275 -- --
NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER
AIRFLOW PERFORMANCE2TFB4024A1D
CFM
230 VOLTS 208 VOLTS
EXTERNALSTATIC
PRESSURE(in. wg.) HI LO HI LO
0.00 1075 890 1015 800
0.10 1030 850 975 755
0.20 975 800 935 715
0.30 915 745 860 670
0.40 845 680 815 605
0.50 770 610 755 535
0.60 525 690 650 450
0.70 600 435 520 360
NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER
AIRFLOW PERFORMANCE2TFB4030A1D
CFM
230 VOLTS 208 VOLTS
EXTERNALSTATIC
PRESSURE(in. wg.) HI LO HI LO
0.00 1140 1095 1100 1015
0.10 1095 1050 1050 975
0.20 1040 1000 995 925
0.30 980 945 930 875
0.40 915 880 860 815
0.50 845 810 795 750
0.60 765 730 720 655
0.70 685 650 605 550
NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER
AIRFLOW PERFORMANCE2TFB4036A1D
CFM
230 VOLTS 208 VOLTS
EXTERNALSTATIC
PRESSURE(in. wg.) HI LO HI LO
0.00 1285 1110 1258 1020
0.10 1242 1072 1215 982
0.20 1196 1029 1170 939
0.30 1150 979 1123 889
0.40 1101 927 1075 837
0.50 1041 883 1014 793
0.60 992 838 965 748
0.70 943 792 917 702
NOTES: WITH WET COIL, FILTER & 10 KW ELECTRIC HEATER
A800984P01A800983P01A800982P01 A801200P01
2TFE3025A1D AIR HANDLER AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)AIRFLOW SETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW1 SW2 SW3 SW4 0.1 0.2 0.3 0.5 0.7 0.9
1.5
LOW(350 CFM/TON) ON ON OFF ON CFM 525 525 500 450 445 440
NORMAL(400 CFM/TON) ON ON OFF OFF CFM 600 600 575 550 550 500
HIGH(450 CFM/TON) ON ON ON OFF CFM 650 650 650 650 625 575
2
LOW(350 CFM/TON) OFF ON OFF ON CFM 700 700 700 675 650 600
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM 800 800 800 800 800 750
HIGH(450 CFM/TON) OFF ON ON OFF CFM 900 900 900 900 875 825
2.5
LOW(350 CFM/TON) ON OFF OFF ON CFM 850 850 850 875 850 850
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM 1000 1000 1000 1000 950 850
HIGH(450 CFM/TON) ON OFF ON OFF CFM 1125 1125 1125 1125 1125 900
3**
LOW(350 CFM/TON) OFF OFF OFF ON CFM 1050 1050 1050 1050 1000 850
NORMAL(400 CFM/TON) OFF OFF OFF OFF CFM 1200 1200 1200 1125 1050 950
HIGH(450 CFM/TON) OFF OFF ON OFF CFM 1300 1300 1250 1175 1100 1050
NOTES:1. ** Factory setting2. At continuous Fan setting: Airflow values are approximately 50% of listed values.3. With wet coil, filter in place, and 10KW electric heater.
10 22-1753-01-0404 (EN)
PerformanceData
AIRFLOW ADJUSTMENTIf the airflow needs to be increased or decreased, see theAirflow Label on the air handler or the Blower PerformanceTable in the Service Facts. Information on changing the speedof the blower motor for your specific outdoor model size is in theBlower Performance Table.
Blower speed changes are made on the ECM Fan Control. TheECM Fan control controls the variable speed motor.
There is a bank of 8 dip switches (see Figure 1), located at theupper part of the board. The dip switches work in pairs to matchthe airflow for the outdoor unit size (tons), cooling airflowadjustment, cooling off delay options, and heating airflowadjustment. The switches appear as shown in Figure 2.
COOLING OFF - DELAY OPTIONS
SWITCH SETTINGS SELECTION NOMINALAIRFLOW
5 - OFF 6 - OFF NONE SAME
5 - ON 6 - OFF 1.5 MINUTES 100% *
5 - OFF 6 - ON 3 MINUTES 50%
5 - ON 6 - ON ENHANCED** 50 - 100%
* - This setting is equivalent to the BAY24X045 relay benefit
** - This ENHANCED MODE selection provides a ramping up and ramping down of the blower speed to provide improved comfort, quietness, and potential energy savings. The graph shows the ramping process.
OFF OFF
50%
80%
100% if necessary
50%
DehumidifyWarm Air Heating
Fast Coil CoolingFast Coil Heating Efficiency
7.5minutes
3minutes
1minute
FA
N O
PE
RA
TIO
N (
CF
M)
as required
INDOOR BLOWER TIMINGThe ICM Fan Control controls the variable speed indoor blower.The FAN-OFF period is set on the ICM Fan Control board bydip switches #5 and #6. The blower off-delay settings are asfollows:
1
DIP SWITCHES (AS SHIPPED)
COOLING HEATING
AIRFLOW
FAN OFFDELAY
AUXILIARYHEAT SPEEDS
2
22-1753-01-0404 (EN) 11
2TFB4018,24,30,36A1D08, D10
2TFB4018,24,30,36A1D05
ElectricalData
200 - 230 VOLT 60 HZ1 PH POWER SUPPLY PER LOCAL CODE
NOTES:
1. FOR 200V OPERATION SWAP RED HIGH VOLTAGE TRANSFORMER LEAD AND INSULATED CAP ON 200V CENTER TRANSFORMER TERMINAL.
2. FOR REPLACEMENT FUSE, USE 5.0 AMP AUTOMOTIVE STYLE FOR ALL MODELS.
200 - 230 VOLT 60 HZ1 PH POWER SUPPLY PER LOCAL CODE
NOTES:
1. FOR 200V OPERATION SWAP RED HIGH VOLTAGE TRANSFORMER LEAD AND INSULATED CAP ON 200V CENTER TRANSFORMER TERMINAL.
2. FOR REPLACEMENT FUSE, USE 5.0 AMP AUTOMOTIVE STYLE FOR ALL MODELS.
12 22-1753-01-0404 (EN)
ElectricalData
2TFE3025A1D05
2TFE3025A1D08, D10
200 - 230 VOLT 60 HZ1 PH POWER SUPPLY PER LOCAL CODE
NOTES:
1. FOR 200V OPERATION SWAP RED HIGH VOLTAGE TRANSFORMER LEAD AND INSULATED CAP ON 200V CENTER TRANSFORMER TERMINAL.
2. FOR REPLACEMENT FUSE, USE 5.0 AMP AUTOMOTIVE STYLE FOR ALL MODELS.
22-1753-01-0404 (EN) 13
RefrigerantCircuit
Refrigerant Circuit Drawing for 2TFB4036 Air Handlers
Refrigerant Circuit Drawing for 2TFB4018,24,30 Air Handlers
From Drawing D801091G01
From Drawing D800930 Sheet 1 Rev 4
14 22-1753-01-0404 (EN)
Refrigerant Circuit Drawing for 2TFE3025 Air Handler
From Drawing D800930 Sheet 2 Rev 4
RefrigerantCircuit
22-1753-01-0404 (EN
)15
2TFB / 2TFE Outline Drawing(All dimensions are in inches)
From Drawing D800913P01 Rev 5
Dim
ensio
ns
P.I.
Trane has a policy of continuous product and product data improvement and it reserves the right to changedesign and specifications without notice.