63
Vane pumps General catalog Single, double & triple T7 - T67 - T6C series Publ. 1 - AM0740 - D 09 / 2004 / FB Replaces : 1 - AM0740 - C L14 - 10740 - 4

Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

  • Upload
    vankiet

  • View
    233

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

Vane pumps

General catalog

Single, double & triple

T7 - T67 - T6C series

Publ. 1 - AM0740 - D 09 / 2004 / FB Replaces : 1 - AM0740 - C L14 - 10740 - 4

Page 2: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

T7B - T7BS

T6C

T7D - T7DS

T7E - T7ES

T7BB - T7BBS

T6CC

T67CB

T7DB - T7DBS

T67DC

T7DD - T7DDS

General characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Minimum and maximum speeds - Pressure ratings - Single pumps . . . . . . . . . . . . . 5

Minimum and maximum speeds - Pressure ratings - Double & triple pumps . . . . . . 6

Minimum allowable inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Main calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Intermittent pressure rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Start-up instructions & recommendations

General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Shaft & coupling data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Specific point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Fluids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12

Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

General characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

VANE PUMPS - GENERAL CATALOG

2

GENERAL

SINGLE

DOUBLE

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 3: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

VANE PUMPS - GENERAL CATALOG

DOUBLE

TRIPLE

3

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Ordering code and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Dimensions and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Ordering code and operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Porting diagrams for double and triple pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Porting diagrams for triple pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 - 63

T7EB - T7EBS

T67EC

T7ED - T7EDS

T7EE - T7EES

T67DBB

T67DCB

T67DCC

T7DDB - T7DDBS

T67DDCS

T7EDB - T7EDBS

T67EDC - T67EDCS

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 4: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

CARACTERISTICS - GENERAL CATALOG

4

CHARACTERISTICS

GREATER FLOW

HIGHER PRESSURE

WIDE SPEED RANGE

BETTER EFFICIENCY

LOW NOISE LEVELS

MOUNTING FLEXIBILITY

CARTRIDGE DESIGN

WIDE RANGE OF ACCEPTABLEVISCOSITIES

FIRE RESISTANT FLUIDS ANDBIODEGRADABLE FLUIDS

GENERAL APPLICATIONSINSTRUCTIONS

These vane pumps have been specially designed for high/low circuit. The combinationof different cartridges in double and triple pumps allows low flow at high pressure(300 bar max.) and high flow at lower pressure. This is a clever way to optimize yourcircuit design.This pump feature will also allow a very fast pressure cycle change with a very pre-cise flow repeatability.

B : .35 to 3.01 in3/rev.C : .66 to 6.10 in3/rev.D : 2.64 to 9.64 in3/rev.E : 8.07 to 16.40 in3/rev.

B : 4650 PSI max. (4350 PSI for multiple pump).C : 4000 PSI max.D : 4060 PSI max. (3500 PSI for multiple pump).E : 3500 PSI max.

Industrial pumps : from 600 to 3600 RPM

Over 94 % under high pressure, which increases productivity and reduces heating andoperation costs.

Increase operator safety and acceptance.

Single pumps : 4 positions.Double pumps : 32 positions.Triple pumps : 128 positions.

Provides for drop-in assemblies. They permit easy conversion and service.B and D cartridges : bi-directionalC and E cartridges : Uni-directional.

Viscosities from 3900 to 60 SUS permit colder starts and hotter running. The balanceddesign compensates for wear and temperature changes. At high viscosity or cold tem-perature, the rotor to side plates gap is well lubricated and improves mechanical effi-ciency.

Including phosphate esters, organic esters, chlorinated hydrocarbons, water glycols,rapeseed may be pumped at higher pressures and with longer service life by thesepumps.

1. Check speed range, pressure, temperature, fluid quality, viscosity and pump rota-tion.2. Check inlet conditions of the pump, if it can accept application requirement.3. Type of shaft : if would support operating torque.4. Coupling must be chosen to minimize pump shaft load (weight, misalignment).5. Filtration : must be adequate for lowest contamination level.6. Environment of pump : to avoid noise reflection, pollution and shocks.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 5: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

SINGLE PUMPS : SPEEDS, PRESSURE RATINGS - GENERAL CATALOG

5

Maximum speed Maximum pressure HF-0, HF-2 HF-1, HF-4, HF-5 HF-3

Theoretical Displacement

Vi

Minimumspeed HF-0, HF-1

HF-2HF-3, HF-4

HF-5 Int. Cont. Int. Cont. Int. Cont.Model of

pump Displ.

in3/rev RPM RPM RPM PSI PSI PSI PSI PSI PSI B02 .35 B03 .60 B04 .78 B05 .97 B06 1.20 B07 1.37 B08 1.51 B09 1.70 B10 1.92

3600 46501) 4200

B11 2.14 B12 2.47 B14 2.70

4350 4000

T7BT7BS

B15 3.01

600

3000

1800

4060 3500

3500 3000 2500 2000

003 .66 005 1.05 006 1.30 008 1.61 010 2.08 012 2.26 014 2.81 017 3.56 020 3.89 022 4.29

2800

025 4.84

4000 3500 2500

028 5.42

T6C

031 6.10

600

2500

1800

3000 2300

3000

2300

2500 2000

B14 2.64 B17 3.30 B20 3.95 B22 4.29 B24 4.86 B28 5.39 B31 5.94

3000 4350

B35 6.80 B38 7.23 2800 4060

3600

B42 8.26 2500 3770 3400

3500 3000

0452) 8.89 3500 3000 2500

T7DT7DS

0502) 9.64

600

2200

1800

3000 2300 3000 2300

2500 2000

042 8.07 045 8.70 050 9.67 052 10.00 054 10.43 057 11.18 062 12.00 066 13.00 072 13.86

2200 3500 3000 3000 2500 2500 2000 T7ET7ES

085 16.40

600

2000

1800

1300 1100 1100 1100 1100 1100

HF-0, HF-2 = Anti-wear petroleum base. HF-1 = Non anti-wear petroleum base. HF-5 = Synthetic fluids. HF-3 = Water-in-oil invert emulsions. HF-4 = Water glycol solutions. 1) Please consult DENISON Hydraulics for applications over 4350 PSI. 2) Ten vanes technology.

For further information or if the performance characteristics outlined above do not meet your own particular requirements, please consult your local DENISON Hydraulics office.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 6: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DOUBLE AND TRIPLE PUMPS : SPEEDS, PRESSURE RATINGS - GENERAL CATALOG

6

Maximum speed Maximum pressure

HF-0, HF-2 HF-1, HF-4,HF-5 HF-3

Theoretical Displacement

Vi

Minimumspeed HF-0,HF-1

HF-2HF-3,HF-4

HF-5 Int. Cont. Int. Cont. Int. Cont.

Model ofpump Displ.

in3/rev RPM RPM RPM PSI PSI PSI PSI PSI PSI B02 .35 B03 .60 B04 .78 B05 .97 B06 1.20 B07 1.37 B08 1.51 B09 1.70 B10 1.92 B11 2.14 B12 2.47 B14 2.70

T7BB T7BBS 46501)

Other pumps 4350

T7BB T7BBS 4200

Other pumps 4000

T7BB/S T67CBT7DB/S T7EB/S T67DBBT67DCBT7DDB/S T7EDB/S

B15 3.01

600 2200 3) 1800

4060 3500

3500 3000 2500 2000

003 .66 005 1.05 006 1.30 008 1.61 010 2.08 012 2.26 014 2.81 017 3.56 020 3.89 022 4.29 025 4.84

4000 3500 2500

028 5.42

T6CCT67CB T67DCT67ECT67DCB T67DCCT67DDCS T67EDC/S

031 6.10

600 2200 3) 1800

3000 2300

3000

2300

2500 2000

B14 2.64 B17 3.30 B20 3.95 B22 4.29 B24 4.86 B28 5.39 B31 5.94 B35 6.80 B38 7.23 B42 8.26

3500 3000

0452) 8.89

3630 3000

2500

T7DB/S T67DC T7DD/S T7EDS T67DBB T67DCB T67DCC T7DDB/S T67DDCS T7EDB/S T67EDC/S

0502) 9.64

600 2200 3) 1800

3000 2300 3000 2300

2500 2000

042 8.07 045 8.70 050 9.67 052 10.00 054 10.43 057 11.18 062 12.00 066 13.00 072 13.86

3500 3000 3000 2500 2500 2000

T7EB/S T67EC T7EDS T7EE/S T67EDB/S T67EDC/S

085 16.40

600 2200 3) 1800

1300 1100 1100 1100 1100 1100

HF-0, HF-2 = Anti-wear petroleum base. HF-1 = Non anti-wear petroleum base.HF-5 = Synthetic fluids.HF-3 = Water-in-oil invert emulsions.HF-4 = Water glycol solutions.1) Please consult DENISON Hydraulics for applications over 4350 PSI. 2) Ten vanes technology.3) Please consult DENISON Hydraulics with higher speeds.

For further information or if the performance characteristics outlined above do not meet your own particular requirements, please consult your local DENISON Hydraulics office.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 7: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

MINIMUM ALLOWABLE INLET PRESSURE (PSI ABSOLUTE) - GENERAL CATALOG

7

Cartridges Speed RPM

Sizes Displ. 1200 1500 1800 2100 2200 2300 2500 2800 3000 3600 Displ.

B02 B02

B03 B03

B04 B04

B05

11.6 11.6

B05

B06 B06

B07 11.9 14.2

B07

B08 B08

B09 12.3 15.2

B09

B10 16.7 B10

B11 B11

B12

11.6 11.6

13.1

B12

B14 B14

B

B15

11.6 11.6 11.6 11.6 11.6 11.6

12.2 14.4 16.4 B15

003 003

005 005

006 006

008 008

010

11.6 13.1

010

012 13.3 012

014

11.6

12.3

14.5

014

017 017

020

11.6

12.3 13.8

14.9 020

022 12.3 13.1

13.1

14.2 15.2 022

025 13.8 13.8 15.2 025

028 13.1

14.2 14.2 15.7 028

C

031

11.6 11.6 11.6

12.3 13.1 16.1 16.1 031

B14 B14

B17 11.6 11.6

B17

B20 11.9 12.5 B20

B22 12.0 12.8 B22

B24 12.5 13.8 B24

B28 12.8 14.5 B28

B31

11.6

13.1 15.2 B31

B35 12.2 14.1 B35

B38 12.5 14.7 B38

B42

11.6 11.6 11.6 11.6

13.1 B42

045 14.2 15.2 045

D

050

11.6 11.6

12.3 14.8 15.8 050

042 042

045 045

050 050

052 052

054

11.6 13.1

054

057 057

062

11.6 11.6

12.3 13.8

14.5

062

066 13.8 15.8 066

072 12.3 12.3

12.3 14.5

15.2 072

E

085 13.1 13.1 14.5 085

Inlet pressure is measured at inlet flange with petroleum base fluids at viscosity between 60 and 300 SUS. The difference

between inlet pressure at the pump flange and atmospheric pressure must not exceed 2.9 PSI to prevent aeration.

Multiply absolute pressure by 1,25 for HF-3, HF-4 fluids.

by 1,35 for HF-5 fluid.

by 1,10 for ester or rapeseed base.

Use the cartridge with the highest absolute pressure for double and triple pumps.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 8: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

PUMP SELECTION - GENERAL CATALOG

8

MAIN CALCULATION

INTERMITTENT PRESSURERATING

To resolveVolumetric displ. Vi [in3/rev.]Available flow qv [GPM]Input power P [HP]

Routine :

1. First calculation Vi =

2. Choice Vi of pump immediatelygreater (see tabulation)

3. Theoretical flow of this pumpVp x n

231

4. Find qvs leakage function of pressureqVs = f(p) on curve at 60 or 115 SUS

5. Available flow qVe = qVi - qVs

6. Theoretical input powerqVi x p1714

7. Find Ps hydrodynamic power loss oncurve

8. Calculation of necessary input powerP = Pi + Ps

9. Results

Performances requiredRequested flow qv [GPM] 19.8Speed n [RPM] 2500Pressure p [bar] 3600

Example :

Vi = = 1.83 in3/rev.

T7B B10, Vi = 1.92 in3/rev.

qVi = = 20.78 GPM

T7B (page 14) : qVs = .79 GPM at3600 PSI, 115 SUS

qVe = 20.78 - .79 = 19.99 GPM

Pi = = 43.64 HP

T7B (page 14) : Ps at 2500 RPM, 3600 PSI = 1.2 HP

P = 43.64 + 1.2 = 44.84 HP

Vi = 1.92 in3/rev.qVe = 19.99 GPM T7B B10P = 44.84 HP

qVi =

Pi =

231 Qn

231 x 19.82500

1.92 x 2500231

20.78 x 36001714

)These calculation steps must be followed for each application.

T7 and T67 units may be operated intermittently at pressures higher than the recom-mended continuous rating when the time weighted average of pressure is less than orequal to the continuous duty pressure rating. This intermittent pressure rating calcula-tion is only valid if other parameters : speed, fluid, viscosity and contamination levelare respected.For total cycle time longer than 15 minutes, please consult your DENISON Hydraulicsrepresentative.

Example : T7B - B10Duty cycle 4 min. at 4650 PSI

1 min. at 500 PSI5 min. at 2300 PSI

= 3070 PSI

3070 PSI is lower than 4200 PSI allowed as continuous pressure for T7B - B10 withHF-0 fluid.

(4 X 4650) + (1 x 500) + (5 x 2300)10

3067

0

1000

2000

3000

4000

5000

0 5 10

Time (minutes)

Pres

sure

(psi

) Average Pressure

Cycle

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 9: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DESCRIPTION - GENERAL CATALOG

9

APPLICATION ADVANTAGES The high pressure capability up to 4650 PSI, in the small envelope, reduces installa-tion costs and provides extended life at reduced pressure.

The high volumetric efficiency, typically better than 94%, reduces heat generation,and allows speeds down to 600 RPM at full pressure.

The high mechanical efficiency, typically better than 94%, reduces energy con-sumption.

The wide speed range (600 RPM at 3600 RPM), combined with large size cartridgedisplacements will optimize operation for the lowest noise level in the smallestenvelope

The low speed (600 RPM), low pressure, high viscosity (3900 SUS) allows applica-tion in cold environment with a minimum energy consumption and without risk ofseizure.

The low ripple pressure (± 29 PSI) reduces piping noise and increases lifetime ofother components in the circuit.

The high resistance to particle contamination, because of the double lip vane,increases pump life.

The large variety of options (cam displacement, shaft, porting) allows customizedinstallation.

Noise : Specially designed to optimize the low noise level characteristics.

Cartridge concept : drops maintenance costs by two.

InletInlet

Pilot recess as required bySAE for full conformity.

Vane is urged outward atsuction ramp by pin force

and centrifugal force.

Cap end outlet port has8-positionsat 45° intervals relative to inlet on

each double and triple pump.

Pin cavity is at a steadypressure equal to that at

discharge port.

90° Section

Section B-B

B

B

Section A-A Side feed holes supply dischargepressure to pin cavities.

Discharge rampwhere unloadedvane moves in..

Suction rampwhere unloadedvane moves out.

Working vane on minor arcseals discharge pressure from

the suction port.

Holes in cam ring improve widecartridge inlet characteristics.

Working vane on major arcpushes fluid to discharge port.

Cartridge are replaceable assemblies. Eachincludes cam ring, rotor, vanes, pins and sideplates.

Shaft end outlet port has 4-positions at 90° intervals

relative to inlet.

Ball bearing holdsshaft in alignment.

Shaft comes in variety ofkeyed and splined options tomeet SAE and ISO 3019-1.

Front & rear sideplates areeach clamped axialy by the

separate discharge pressures.

Cartridge is replaceable assemblyincluding cam ring, rotor, vanes,

pins and sideplate.

Outlet

A

A

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 10: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

GENERAL :

ROTATION & PORTS INDICATION

START-UP CHECK-UP

All DENISON Hydraulics vane pumps & motors are individually tested to providethe best quality & reliability. Modifications, conversions & repairs can only be doneby authorized dealers or OEM to avoid invalidation of the guarantee.

The pumps & motors are to be used in the design limits indicated in all the sales bul-letins. Please contact DENISON when tresspassing the catalog limits.

Do not modify or work on the pump (or motor) under pressure or when the electricmotor (or any drive) is on.

Qualified personnel is required to assemble and set-up hydraulic devices.

Always conform yourself to the valid regulations (safety, electrical, environment...).

The following instructions are important to follow to obtain a good service life timefrom the unit.

The rotation and ports orientation are viewed from the shaft end.

CW stands for clockwise, right-hand rotation.

CCW stands for counter-clockwise, left-hand rotation.

The distance between the suction pipe & the return lines in the tank should be at itsmaximum.

A bevel on both suction & return lines is recommended to increase the surface andso lower the velocity. We suggest a 45° minimum angle.

Velocities : inlet 1,64 < x < 6,23 ft per sec.: return x < 19,7 ft per sec.: Always insure that all return and suction lines are under the oil level to

avoid forming aeration or vortex effect. This should be done under the most critical situation (all cylinders extended for example). Straight and short pipes are the best.

Q (GPM)3.12 x π x r2 (in)

The size of the air filter should be 3 times greater than the max. instant return flow(all cylinders in movement for example).

If the pump is in the tank, please choose the NOP option (no paint) and use a shortinlet pipe.

DENISON does not recommend inlet strainers. If needed, a 100 mesh (149 microns)is the finest mesh recommended.

A coaxial drive is recommended. For any other type of drives, please contact DENI-SON.

Make sure that all protective plugs & covers have been removed.

Check the pump rotation versus the E-motor or engine rotation.

The tank has been filled up with a clean fluid in proper conditions.

Flushing the system with an external pump prior to the start-up is good.

To allow a good priming of the pump, the air should be bled off.

The first valve on the circuit should be open to tank.

Air bleed off valves are available on the market place.

It is possible to bleed off the air by creating a leak in the P port of the pump.

Warning : this has to be done in low pressure mode as it could create a danger-ous fluid leak. Make sure that the pressure cannot rise (open center valve totank, pressure relief valve unloaded ...).

When oil free of air appears, tighten the connectors to the correct torque.

START-UP INSTRUCTIONS & RECOMMENDATIONS - GENERAL CATALOG

10

Check that the assembly of the power unit is correct :

Start-up :

= ft/sV =

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 11: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

SHAFT & COUPLING DATA :

COUPLINGS AND FEMALESPLINES

KEYED SHAFTS

SHAFT LOADS

SPECIFIC POINTS :

MINIMUM INLET PRESSURE

MAXIMUM INLET PRESSURE

MINIMUM OUTLET PRESSURE

VERTICAL MOUNT

FLUIDS :

DENISON CLASSIFICATIONS

FILTRATION RECOMMENDATIONS

RECOMMENDED FLUIDS

The pump should prime within a few seconds. If not, please read the troubleshootingguide (1 - EN0721 - *).

If the pump is noisy, please troubleshoot the system.

Never operate the pump at top speed and pressure without checking the completion ofpump priming.

The mating female spline should be free to float and find its own center. If bothmembers are rigidly supported, they must be aligned within 0.006” TIR or less toreduce fretting. The angular alignment of two splines axes must be less than ± 0.002”per 1” radius.

The coupling spline must be lubricated with a lithium molydisulfide grease, disulfideof molybdenum or a similar lubricant.

The coupling must be hardened to a hardness between 29 and 45 HRC.The female spline must be made to conform to the Class 1 fit as described in SAE-

J498b (1971). This is described as a Flat Root Side Fit.

DENISON Hydraulics supplies the T6 series keyed shaft pumps with high strengthheat-treated keys. Therefore, when installing or replacing these pumps, the heat-treatedkeys must be used in order to ensure maximum life in the application. If the key isreplaced, it must be a heat-treated key between 27 and 34 R.C. hardness. The cornersof the keys must be chamfered by 0.03 to 0.04 at 45° to clear the radii in the key way.

The alignment of keyed shafts must be within tolerances given for splined shafts hereabove.

These products are primarily designed for coaxial drives which do not impose axial orside loading on the shaft. Contact DENISON for specific applications.

Please read the charts in the sales leaflets as the minimum requested inlet pressurevaries versus the displacement and the speed.Never go under 11.6 PSI Absolute (-2.9 PSI G).

It is recommended to always have at least 22 PSI differential between inlet and outlet.Standard shaft seals are limited to 10 PSI G but some allow 100 PSI G. Please contactDENISON for more information.

It is recommended to always have at least 22 PSI differential between inlet and outlet.

When assembled vertically, always be careful to prevent any air from being trapped inthe pump (behind the shaft seal for example).

Type of fluids : For all types of fluids, DENISON’s products have different pressures,speeds & temperature limits. Please refer to the sales leaflets.HF-0 = Anti-wear petroleum base.HF-1 = Non anti-wear petroleum base.HF-2 = Anti-wear petroleum base.HF-3 = Water-in-oil invert emulsions.HF-4 = Water glycol solutions.HF-5 = Synthetic fluids.

NAS 1638 class 8 or better.ISO 18 / 14 or better.Inlet strainers : DENISON does not recommend inlet strainers.

If requested, a 100 mesh (149 microns) is the finest mesh recommend-ed.

Petroleum based antiwear R & O fluids.These fluids are the recommended fluids for pumps & motors. Maximum catalog rat-ings and performance data are based on operation with these fluids. These fluids arecovered by DENISON Hydraulics HF-0 and HF-2 specifications.

START-UP INSTRUCTIONS & RECOMMENDATIONS - GENERAL CATALOG

11Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 12: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ACCEPTABLE ALTERNATE FLUIDS

VISCOSITY

VISCOSITY INDEX

TEMPERATURES

WATER CONTAMINATION IN THEFLUID

FLUID POWER FORMULAS

Pump input torque lbs. in.

Pump input power HP

Pump output flow U.S. gpm

Fluid motor speed rpm

Fluid motor torque lbs. in

Fluid motor power HP

The use of fluids other than petroleum based antiwear R & O fluids requires that themaximum ratings of the pumps will be reduced. In some cases the minimum replenish-ment pressures must be increased. Consult specific sections for more details (page 11).

IndutrialMax. (cold start, low speed & pressure) 3900 SUSMax. (full speed & pressure) 500 SUSOptimum (max. life) 140 SUSMin. (full speed & pressure forHF-1, HF-3, HF-4 & HF-5 fluids) 90 SUSMin. (full speed & pressure forHF-0 & HF-2 fluids) 60 SUS

90 min. Higher values extend the range of operating temperatures.

The usual limitating factor of temperature (low or high) comes from the obtained vis-cosity. The seals are sometimes the limit : standard seals range from -9.4° F to 194° F.

Maximum fluid temperature (θ) ° FHF-0, HF-1, HF-2 + 212HF-3, HF-4 + 122HF-5 + 158Biodegradable fluids (esters & rapeseed base) + 149

Minimum fluid temperature (θ) (also depend on max. viscosity) ° FHF-0, HF-1, HF-2, HF-5 - 0.4HF-3, HF-4 + 50Biodegradable fluids (esters & rapeseed base) - 0.4

Over or under these values, please contact DENISON.

Maximum acceptable content of water :0,10 % for mineral base fluids.0,05 % for synthetic fluids, crankcase oils, biodegradable fluids.

If the amount of water is higher, then it should be drained off the circuit.

pressure (PSI) x displacement in3/rev2 π x mech. eff.

rpm x (in3/rev) x pressure (PSI)395934 x overall eff.

rpm x (in3/rev) x volumetric eff.231

231 x flow rate (U.S. gpm) x volumetric eff.displacement (in3/rev.)

pressure (PSI) x displacement (in3/rev) x mech. eff.2 π

rpm x (in3/rev) x (PSI) x overall eff.395934

START-UP INSTRUCTIONS & RECOMMENDATIONS - GENERAL CATALOG

12Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 13: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

GENERAL CHARACTERISTICS - GENERAL CATALOG

13

GENERAL CHARACTERISTICS

SAE 4 bolts

J518 - ISO/DIS 6162-1 Mounting

standard

Weight without

connector and

bracket - Lbs

Moment of

inertia

Lb.in2Suction Pressure

T7BISO 3019-2

100 A2 HW

T7BSSAE J744

SAE B

50.7 1.1 1"1/2 1" or 3/4"

T6CSAE J744

SAE B 34.6 2.6 1"1/2 1"

T7DISO 3019-2

125 A2 HW

T7DSSAE J744

SAE C

57.3 6.7 2" 1"1/4

T7E ISO 3019-2

125 A2 HW

T7ES SAE J744

SAE C

95.4 21.3 3 " 1"1/2

P1 P2

T7BBISO 3019-2

100 A2 HW

T7BBSSAE J744

SAE B

71.9 2.3 2"1/2 1" or 3/4" 3/4"

T6CCSAE J744

SAE B 57.3 5.8 2"1/2 or 3" 1" 1" or 3/4"

T67CBSAE J744

SAE B 57.3 3.9 2"1/2 1" 3/4"

T7DBISO 3019-2

125 A2 HW

T7DBSSAE J744

SAE C

85.1 9.0 3" 1"1/4 1" or 3/4"

T67DCSAE J744

SAE C 85.1 9.0 3" 1"1/4 1" or 3/4"

T7DDISO 3019-2

125 B4 HW

T7DDSSAE J744

SAE C

123.4 12.4 4" 1"1/4 1"1/4

T7EBISO 3019-2

125 A2 HW

T7EBSSAE J744

SAE C

121.2 22.5 3"1/2 1"1/2 3/4"

T67EC SAE J744

SAE C 121.2 24.2 3"1/2 1"1/2 1"

T7ED ISO 3019-2

125 A2 HW

T7EDSSAE J744

SAE C

145.5 27.2 4" 1"1/2 1"1/4

T7EE ISO 3019-2

250 B4 HW

T7EES SAE J744

SAE E

209.4 33.2 4" 1"1/2 1"1/2

P1 P2 P3

T67DBB 8.9

T67DCB 10.1 3/4"

T67DCC

SAE J744

SAE C 134.5

11.4

4" 1"1/4 1"

1" or 3/4"

T7DDBISO 3019-2

125 B4 HW

T7DDBSSAE J744

SAE C

145.5 13.5 4" 1"1/4 1"1/4 1" or 3/4"

T67DDCSSAE J744

SAE C 145.5 14.7 4" 1"1/4 1"1/4 1" or 3/4"

T7EDBISO 3019-2

250 B4 HW

T7EDBSSAE J744

SAE E

224.9 26.1 4" 1"1/2 1"1/4 1" or 3/4"

T67EDCISO 3019-2

250 B4 HW

T67EDCSSAE J744

SAE E

224.9 27.4 4" 1"1/2 1"1/4 1" or 3/4"

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 14: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

50

55

60

65

0 500 1000 1500 2000 2500 3000 3500 4000 4500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

14

ORDERING CODE - T7B - T7BS SERIES

Model No. T7B or T7BS - B10 - 1 R 00 - A 1 M0 - ..

T7B series - 100 A2 HWISO 2 bolts 3019-2 mounting flangeT7BS series - SAE B 2 boltsMounting flange J744DisplacementVolumetric displacement (in3/rev)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51Type of shaft T7B - T7BS2 = keyed (ISO R775)Type of shaft T7BS1 = keyed (SAE B)3 = splined ( SAE B)4 = splined (SAE BB)

ModificationsMounting w/connection variables4 bolts SAE flange (J518C)

Metric thread UNC threadT7B - T7BS T7BSM0 M1 00 01

P 1” 3/4” 1” 3/4”S 1”1/2

Seal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

P = Pressure portS = Suction port

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7B - B10

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Maximum permissible axial load Fa = 180 Lbs

0

0,5

1

1,5

2

0 500 1000 1500 2000 2500 3000 3500 4000 4500

115 SUS

60 SUS

0

0,5

1

1,5

2

2,5

3

3,5

0 500 1000 1500 2000 2500 3000 3500 4000 4500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 3000 RPM

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

0

50

100

150

200

250

300

600 1200 1800 2400 3000 3600

F

Fa

Shaft keyed N°1

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is more than 50% of theoretical flow.

P P P P

S

S

S

00 01 02 03

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 15: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 50.7 Lbs - T7B AND T7BS SERIES

15

6.87

F

G

H D

IA

6.63 2.82

3.24 1.50.31

.25 MAXI

4.0

00

3.9

98

DIA

2.0

2D

IA

.98

2M

AX

.87

5.8

74

DIA.06 x 45°

.38

.05 x 45°

SHAFSHAFT CODE 1T CODE 1 (KEYED SAE "B")

MOUNTING TORQUE 138 ft.lbs

1.60

.31

TT7BSBS SESERIRIE (FLANGE SAE "B")

.96

.06 x 45°

3.0

01.80

.31

.96

.06 x 45°

3.9

37

3.9

36

DIA

1.1

11

MA

X

.98

7.9

82

DIA

1.57

.08 x 45°

.35

.06 x 45°

D2.7

6

1.3

81.41

.70

C

.50 2.76

.39

KEY .315 x .276

E DIA PRESSURE1.50 DIA SUCTION

S P

SHAFSHAFT CODE 2T CODE 2 (KEYED ISO R775)

A - 4 HOLES

B - 4 HOLES

T7BT7B SERIESERIE (FLANGE ISO 3019/2 100A2HW)

SHAFT CODE 4SHAFT CODE 4 SAE BB INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

SHAFSHAFT CODE 3T CODE 3 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

4.75

C.G.

T7BS T7B00 01 M0 M1

A DIA 3/8 16 UNC x .75 deep M10 x .75 deepB DIA 1/2 13 UNC x .88 deep M12 x .88 deep

C 1.03 .87 1.03 .87D 2.06 1.87 2.06 1.87

E DIA 1.00 .75 1.00 .75F 5.75 5.51G 2.87 2.75

H DIA .56 .55

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 146152 182463 182464 18246

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

1) B11 - B12 - B14 = 4350 PSI max. int. 2) B15 = 4060 PSI max. int.

PressurePort Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI p = 2000 PSI p = 4650 PSI p = 100 PSI p = 2000 PSI p = 4650 PSI

T7BT7BS

B02 .35 in3/rev 2.76 2.31 1.73 0.97 4.53 9.34B03 .60 in3/rev 4.66 4.21 3.63 1.08 6.78 14.49B04 .78 in3/rev 6.09 5.64 5.06 1.17 8.47 18.36B05 .97 in3/rev 7.56 7.11 6.53 1.25 10.22 22.35B06 1.20 in3/rev 9.32 8.87 8.29 1.36 12.30 27.11B07 1.37 in3/rev 10.70 10.25 9.67 1.44 13.93 30.84B08 1.51 in3/rev 11.79 11.34 10.76 1.50 15.23 33.80B09 1.70 in3/rev 13.27 12.82 12.24 1.59 16.97 37.80B10 1.92 in3/rev 14.98 14.53 13.95 1.69 19.00 42.43B11 2.14 in3/rev 16.64 16.19 15.681) 1.79 20.97 44.051)B12 2.47 in3/rev 19.26 18.81 18.291) 1.95 24.07 50.691)B14 2.70 in3/rev 21.02 20.57 20.051) 2.05 26.16 55.151)B15 3.01 in3/rev 23.49 23.04 22.592) 2.20 29.08 57.392)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 16: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

16

ORDERING CODE - T6C SERIES

Model No. T6C - 022 - 1 R 00 - B 1 - ..

Series SAE B 2 boltsMounting flange J744DisplacementVolumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Type of shaft1 = keyed (SAE B)2 = keyed (non SAE)3 = splined (SAE B)4 = splined (SAE BB)

ModificationsSeal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

P = Pressure portS = Suction port

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T6C - 022

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Maximum permissible axial load Fa = 180 Lbs

55

60

65

70

75

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is more than 50% of theoretical flow.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 170 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

0

0,5

1

1,5

2

2,5

3

3,5

4

4,5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2800 RPM

0

50

100

150

200

250

600 1000 1400 1800 2200 2600

Shaft keyed n°1F

Fa

Shaft keyed N°1

P P P P

S

S

S

00 01 02 03

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 17: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 34.6 Lbs - T6C SERIES

17

6.87

5.75

2.87

.56 DIA

5.3

1

3.0

0

6.36

3.24 1.50

.38

.31

.25 MAX

2.81

1.50

.05 x 45°

.06 x 45°

4.0

00

3.9

98

DIA

2.0

2D

IA

M8 x

.6

3 D

EE

P

.87

5.8

74

DIA

.98

2M

AX

KEY .250 .248

S P2.7

6

1.3

8 2.0

6

1.0

3

1.41

.70

1.03

.52

.50

.31

2.29

1.25

.06 x 45°

.87

5.8

74

DIA

KEY .1875 .1855

.96

6M

AX

1.00 DIA PRESSURE1.50 DIA SUCTION

1.79

.31

.96

.06 x45°

1.60

.31

.96

.06 x 45°

1/2 13UNC x .88 DEEP-4 HOLES

3/8 16UNC x .75 DEEP-4 HOLES

SHAFSHAFT CODE 1T CODE 1 (Keyed SAE B )

SHAFSHAFT CODE 2T CODE 2 SHAFSHAFT CODE 3T CODE 3 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

SHAFSHAFT CODE 4T CODE 4 SAE BB INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

MOUNTING TORQUE 117 ft.lbs

(Keyed no SAE)

C.G.

2.98

Shaft torque limits [in3/rev. x PSI] Shaft Vi x p max.

1 14473 2 12666 3 18246 4 19309

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

Port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI p = 2000 PSI p = 3500 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI

T6C

003 .66 in3/rev 5.14 3.85 2.95 2.11 8.45 13.38005 1.05 in3/rev 8.18 6.86 5.99 2.29 12.00 19.59006 1.30 in3/rev 10.13 8.84 7.94 2.40 14.28 23.57008 1.61 in3/rev 12.55 11.26 10.36 2.54 17.11 28.53010 2.08 in3/rev 16.22 14.93 14.03 2.76 21.38 36.00012 2.26 in3/rev 17.64 16.35 15.45 2.84 23.05 38.92014 2.81 in3/rev 21.88 20.59 19.69 3.09 27.99 47.56017 3.56 in3/rev 27.73 26.44 25.54 3.43 34.81 59.51020 3.89 in3/rev 30.34 29.05 28.15 3.58 37.86 64.85022 4.29 in3/rev 33.43 32.14 31.24 3.76 41.47 71.16025 4.84 in3/rev 37.71 36.42 35.52 4.01 46.46 79.90028 5.42 in3/rev 42.23 40.94 40.321) 4.27 51.74 76.731)031 6.10 in3/rev 47.56 46.27 45.651) 4.58 57.95 86.061)

1) 028 - 031 = 3000 PSI max. int. Port connection can be furnished with metric threads.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 18: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

18

ORDERING CODE - T7D - T7DS SERIES

Model No. T7D or T7DS - B42 - 1 R 00 - A 1 M0 - ..

T7D series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7DS series - SAE C 2 boltsMounting flange J744DisplacementVolumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Type of shaft T7DS1 = keyed (SAE C 32 - 1)2 = keyed (non SAE)3 = splined ( SAE C 32 - 4)4 = splined (non SAE)Type of shaft T7D - T7DS5 = keyed (ISO 3019-2 - G32M)

ModificationsMounting w/connection variables4 bolts SAE flange J518

P = 1”1/4 - S = 2”UNC Metric

T7D M0T7DS 00 M0 Y01)

1) 3630 PSI max. int.Seal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

P = Pressure portS = Suction port

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7D - B31

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Maximum permissible axial load Fa = 270 Lbs

0

1

2

3

4

5

6

7

8

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

55

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500 4000

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

8

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

50

100

150

200

250

300

350

400

600 900 1200 1500 1800 2100 2400

F

Fa

Shaft keyed N°1

Pressure p [PSI]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is more than 50% of theoretical flow.

P P P P

S

S

S

00 01 02 03

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 19: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 57.3 Lbs - T7D AND T7DS SERIES

19

ED

IA

8.36

C

D

6.1

7

3.2

5

7.28 3.29

3.44 1.50 .50

.31

.25 MAXI

5.0

00

4.9

98

DIA

2.5

3D

IA

1.3

89

MA

X

1.2

50

1.2

48

DIA

.09 x 45°

SHAFT CAFT CODEDE 11( Keyed SAE C )

M10 x .79 DEEP

KEY .313 .311

MOUNTING TORQUE 138 ft.lbs

3.06 (*)

.311.89

.09 x 45°

2.17

.31

1.50

.09 x 45°

1.94

SHAFSHAFT CODEDE 33SAE C INVOLUTE SPLINE DATACLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/2414 THEETH- 30° PRESSURE ANGLE

SHSHAFT CT CODEDE 44SAE C Spc (*) INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FITJ498b - PITCH 12/24

14 THEETH- 30° PRESSURE ANGLE

T7T7DS

.09 x 45°

1.3

89

MA

X

1.2

50

1.2

48

DIA

1.50

2.88

KEY .313 .311

SHSHAFT CT CODEDE 22

.62

PS 2.3

11.1

6

3.0

6

1.5

3

1.19

.59

1.69

.84

1.25 DIA PRESSURE2.00 DIA SUCTION

B DIA x .88 DEEP

A DIA x .94 DEEP T7DT7D.25 MAXI

SHAFSHAFT CODEDE 55(Keyed ISO R775)

1.97

1.2

61

1.2

60

DIA

1.3

89

MA

X

2.5

3D

IA

.09 x 45°

KEY .394 x .315

M10 x .79 DEEP

3.44

4.9

21

4.9

19

DIA

.354

5.80

.31

.31

(Keyed no SAE)

C.G.

3.00

T7DS T7D00 M0 Y0 1) M0

A DIA 1/2 - 13 UNC M12 M12 M12B DIA 7/16 - 14 UNC M12 M10 M12

C 7.12 7.09D 3.56 3.54

E DIA .69 .71

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 382992 306383 542074 542075 39238

1) 3630 PSI max. intOPERATING CHARACTERISTICS - TYPICAL [115 SUS]

1) B35 - B38 = 4060 PSI max. int. 2) B42 = 3770 PSI max. int. 3) 045 = 3500 PSI max. int. 4) 050 = 3000 PSI max. int.* special 2”1/2 (2.5 dia) suction also available - Please contact DENISON Hydraulics

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =4350 PSI p =100 PSI p =2000 PSI p = 4350 PSI

T7DT7DS

B14 2.64 in3/rev 20.54 18.81 16.82 3.23 27.56 56.83B17 3.30 in3/rev 25.68 23.94 21.96 3.53 33.64 69.87B20 3.95 in3/rev 30.82 29.08 27.09 3.84 39.73 82.90B22 4.29 in3/rev 33.43 31.69 29.71 3.99 42.82 89.54B24 4.86 in3/rev 37.85 36.12 34.13 4.25 48.06 100.76B28 5.39 in3/rev 42.04 40.30 38.31 4.50 53.02 111.39B31 5.94 in3/rev 46.32 44.58 42.59 4.75 58.09 122.25B35 6.80 in3/rev 52.98 51.24 49.501) 5.15 65.97 130.001)B38 7.23 in3/rev 56.35 54.62 52.881) 5.35 69.97 138.001)B42 8.26 in3/rev 64.34 62.61 61.112) 5.82 79.43 145.842)045 8.89 in3/rev 69.29 66.90 65.193) 6.65 85.16 144.193)050 9.64 in3/rev 75.14 72.75 71.564) 7.00 92.09 136.874)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 20: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

20

ORDERING CODE - T7E - T7ES SERIES

Model No. T7E or T7ES - 072 - 1 R 00 - A 1 M0 - ..T7E series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7ES series - SAE C 2 boltsMounting flange J744DisplacementVolumetric displacement (in3/rev)042 = 8.07045 = 8.70050 = 9.67052 = 10.00054 = 10.43057 = 11.18062 = 12.00066 = 13.00072 = 13.86085 = 16.40Type of shaft T7E - T7ES5 = keyed (ISO R775 - G38M)Type of shaft T7ES1 = keyed (SAE CC)2 = keyed (non SAE)3 = splined (SAE C)4 = splined (SAE CC)

ModificationsMounting w/connection variables4 bolts SAE flange (J518)

Metric thread UNC threadT7E - T7ES T7ES

M0 00 P 1” 1/2S 3”

Seal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

P = pressure portS = Suction port

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7ES - 050

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Maximum permissible axial load Fa = 449 Lbs

0

1

2

3

4

5

6

7

8

9

0 500 1000 1500 2000 2500 3000 3500

115 SUS

60 SUS

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

8

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

150

200

250

300

350

400

450

500

550

600

650

700

600 1000 1400 1800 2200

F

Fa

Shaft keyed N°1

Pressure p [PSI]

Pressure p [PSI] Speed n [RPM]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Do not operate pump more than 5 seconds at any speed or viscosity if internal leakage is more than 50% of theoretical flow.

P P P P

S

S

S

00 01 02 03

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 21: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS - Weight : 95.4 Lbs - T7E - T7ES SERIES

21

-

8.39

K

K/2 5.81 DIA

dD

IA

7.3

8

3.8

8

8.87 3.58

4.33 2.06 W.31

.25 MAXI2.00

SD

IA

3.0

0D

IA

1.6

68

MA

X

1.5

00

1.4

98

DIA

.09 x 45°

KEY .375 .373

M10 x .79 DEEP

e x 45° SHSHAFT CAFT CODE 1DE 1

( Keyed SAE C-C )

MOUNTING TORQUE 138 ft.lbs

SHSHAFT CAFT CODE 2DE 2

.69

1.41

.70

2.7

5 PS4.1

9

2.0

9

2.44

1.22

2.95 DIA SUCTION 1.50 DIA PRESSURE

5/8 11 UNC .94 DEEP - 4 HOLESM16 x .94 DEEP (METRIC VERSION)

2.20

.31

1.50

2.45

.31

1.24

.09 x 45°.09 x 45°

SHAFT CODE 3SHAFT CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHAFT COSHAFT CODE 4DE 4 SAE CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

.09 x 45°

1.50

2.44

KEY .313 .311

1.2

50

1.2

48

DIA

1.3

89

MA

XI

( Keyed no SAE )

1/2 13 UNC .92 DEEP - 4 HOLESM12 x .92 DEEP (METRIC VERSION)

T7T7ESES

T7T7E

.09 x 45°

1.3

8

.393.54

1.97

1.6

26

MA

X

SD

IA

1.4

97

1.4

96

DIA

KEY .394 x .315

M10 x .79 DEEP

W

e x 45°

SHAFT CODSHAFT CODE 55 ( Keyed ISO/R775 - G38M)

.31

C.G.

4.01

Alternate mounting flange

Series S DIA e x 45° W K d DIAMax. Min.

T7E 4.921 4.919 .079 .374 7.087 .709T7ES 5.000 4.998 .051 .500 7.126 .689

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 482732 306383 542074 542075 48273

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI P = 2000 PSI P =3500 PSI p =100 PSI p =2000 PSI p = 3500 PSI

T7ET7ES

042 8.07 in3/rev 62.92 60.37 58.52 8.09 78.44 133.80045 8.70 in3/rev 67.72 65.17 63.32 8.37 84.04 143.60050 9.67 in3/rev 75.38 72.83 70.98 8.82 92.97 159.24052 10.00 in3/rev 78.37 75.82 73.97 8.99 96.47 165.36054 10.43 in3/rev 81.27 78.72 76.87 9.17 99.75 177.46057 11.18 in3/rev 87.12 84.57 82.72 9.51 106.57 189.84062 12.00 in3/rev 93.54 90.99 89.14 9.88 114.17 196.34066 13.00 in3/rev 101.44 98.89 97.04 10.34 123.38 212.46072 13.86 in3/rev 108.00 105.45 103.60 10.72 131.04 225.86085 16.40 in3/rev 127.79 126.131) - 11.88 101.661) -

1) 085 = 1300 PSI max. int.* special 3”1/2 (3.5 dia) suction also available - Please contact DENISON Hydraulics

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 22: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

22

ORDERING CODE - T7BB - T7BBS SERIES

Model No. T7BB or T7BBS - B10 - B10 - 1 R 00 - A 1 M1 - ..

T7BB series - 100 A2 HWISO 2 bolts 3019-2 mounting flangeT7BBS series - SAE B 2 boltsMounting flange J744Displacement P1 and P2Volumetric displacement (in3/rev)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51Type of shaft T7BB - T7BBS5 = keyed (ISO R775)Type of shaft T7BBS1 = keyed (non SAE)2 = keyed (SAE BB)3 = splined ( SAE B)4 = splined (SAE BB)

ModificationsMounting w/connection variables4 bolts SAE flange (J518)

Metric thread UNC threadT7BB - T7BBS T7BBS

M0 M1 00 01P1 1” 3/4” 1” 3/4”P2 3/4”S 2”1/2

Seal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7BB - B10 - B04

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Maximum permissible axial load Fa = 180 Lbs

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

50

100

150

200

250

300

350

600 1000 1400 1800 2200 2600

F

Fa

Shaft keyed N°1

55

60

65

70

0 500 1000 1500 2000 2500 3000 3500 4000 4500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

0,5

1

1,5

2

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P1-P2

P1-P2

Pressure p [PSI]

0

0,5

1

1,5

2

2,5

3

3,5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2800 RPM

P1-P2

P1-P2

P1-P2

Pressure p [PSI] Speed n [RPM]

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

P1 P2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 23: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 71.9 Lbs - T7BB AND T7BBS SERIES

23

3.3

12.9

2

M

S P1P1

MM

G DIA

6.8

7

F

G

.87

1.8

7

2.00

1.00

3.5

0

1.7

5

D

C

.50 2.76

.391.57

3.9

37

3.9

36

DIA

.06 x 45°

.9845

.9840

DIA

1.1

11

MA

X

.08 x 45°

.35

.75 DIA PRESSUREE DIA PRESSURE

2.50 DIA SUCTION

A - 4 HOLES

B - 4 HOLES A - 4 HOLES

KEY .315 x .276

2.9

4

1.504.003.88

10.33 2.29

.31

.25 MAXI1.25

4.0

00

3.9

98

DIA

2.0

2D

IA

.875

.873

DIA.06 x 45°

.05 x 45°

.38MOUNTING TORQUE 138 ft.lbs

MOUNTING TORQUE 45 ft.lbs

.966

MA

XI

2.81

.31

1.50

1.0

00

.999

DIA.06 x 45°

1.1

11

MA

X

1.60

.31.96

.06 x 45°

1.80

.31

.97

.06 x 45°

KEY .1875 .1855

M8 x .63 DEEP

KEY .250 .248

(Keyed SAE "B-B")

(KEYED NON SAE)

(KEYED ISO R775)

(FLANGE ISO 3019/2 100A2HW)

(FLANGE SAE "B")

SHAFSHAFT COT CODEDE 22

T7BBS SERIET7BBS SERIE

SSHAFAFT CODE 1T CODE 1

SSHAFAFT CODE 5T CODE 5

T7BB SERIET7BB SERIE

SSHAFAFT CODE 3CODE 3 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

SHAFSHAFT CODE 4T CODE 4 SAE B-B INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

3.0

0

P2P2

C.G.

4.57

T7BBS T7BB00 01 M0 M1

A DIA 3/8 16 UNC x .75 deep M10 x .75 deepB DIA 1/2 13 UNC x .88 deep M12 x .88 deep

C 1.03 .87 1.03 .87D 2.06 1.87 2.06 1.87

E DIA 1.00 .75 1.00 .75F 5.75 5.51

G DIA .56 .55

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 122662 189723 182464 289375 22409

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

1) B11 - B12 - B14 = 4350 PSI max. int. 2) B15 = 4060 PSI max. int.

PressurePort Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI p = 2000 PSI p = 4650 PSI p = 100 PSI p = 2000 PSI p = 4650 PSI

P1&P2

B02 .35 in3/rev 2.76 2.31 1.73 0.97 4.53 9.34B03 .60 in3/rev 4.66 4.21 3.63 1.08 6.78 14.49B04 .78 in3/rev 6.09 5.64 5.06 1.17 8.47 18.36B05 .97 in3/rev 7.56 7.11 6.53 1.25 10.22 22.35B06 1.20 in3/rev 9.32 8.87 8.29 1.36 12.30 27.11B07 1.37 in3/rev 10.70 10.25 9.67 1.44 13.93 30.84B08 1.51 in3/rev 11.79 11.34 10.76 1.50 15.23 33.80B09 1.70 in3/rev 13.27 12.82 12.24 1.59 16.97 37.80B10 1.92 in3/rev 14.98 14.53 13.95 1.69 19.00 42.43B11 2.14 in3/rev 16.64 16.19 15.681) 1.79 20.97 44.051)B12 2.47 in3/rev 19.26 18.81 18.291) 1.95 24.07 50.691)B14 2.70 in3/rev 21.02 20.57 20.051) 2.05 26.16 55.151)B15 3.01 in3/rev 23.49 23.04 22.592) 2.20 29.08 57.392)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 24: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

24

ORDERING CODE - T6CC SERIES

Model No. T6CC W - 022 - 008 - 1 R 00 - C 1 00 - ..

Series SAE B 2 boltsMounting flange J744Severe duty shaftDisplacement P1 and P2Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Type of shaft Severe duty shaft (T6CCW only)1 = keyed (non SAE) 2 = keyed (SAE BB)3 = splined (SAE BB)5 = splined (SAE B)Direction of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

ModificationsMounting w/connection variables4 bolts SAE flange (J518)

P1 = 1” - S = 3” P1 = 1” - 2”1/22)00 01 10 11

P2 1” 3/4”1) 1” 3/4”1) for 2.81 in3/rev. max.2) for 7.69 in3/rev. max.The largest cartridge must be alwaysmounted in the front.

Seal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination (see page 62)00 = standard

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T6CC - 022 - 022

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Maximum permissible axial load Fa = 180 Lbs

60

65

70

75

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P1-P2

P1-P2

0

1

2

3

4

5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPMn = 1800 RPM [115 SUS]n = 2800 RPM

P1-P2

P1-P2

P1-P2

50

100

150

200

250

300

350

600 1000 1400 1800 2200 2600

F

Fa

Shaft keyed N°1

P1 P2

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 25: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 57.3 LBS - T6CC SERIES

25

3.3

12

.88

10.46 2.81

3.47 4.00 1.50

6.87

5.75

2.87

3.0

0

.56

DIA

MOUNTING TORQUE 117 ft.lbs

D

MOUNTING TORQUE 45 ft.lbs

.38

.25 MAXI

.31

4.0

00

3.9

98

DIA

2.0

2D

IA

1.1

11

MA

X

1.0

00

.968

DIA

.06 x 45°

KEY .250 .248

M8 x .63 DEEP

.05 x 45°

T6CCWT6CCW SSHAFAFT CODECODE 22

( Keyed SAE B-B )

.96

6M

AX

.875

.874

DIA

KEY .1875 .1855

2.29

.31

SSHAFAFT CODECODE 11

.06 x 45°

1.00 DIA PRESSUREH DIA SUCTIONC DIA PRESSURE

F

A

B G 1.03

.52

2.0

6

1.0

3

P2P2 S P1P1

E-4 HOLESK-4 HOLES

E-4 HOLES

1.79.31

.96

.06 x 45°

.31

1.60

.96

.06 x 45°

SSHAFAFT CODET CODE 33 SAE BB INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

SSHAFAFT CODECODE 55 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/3213 TEETH - 30° PRESSURE ANGLE

1.25

1.50

( Keyed no SAE )

C.G.

4.96

Alternate ports S = 3" S = 2"1/2 2)

F 4.19 3.50 G 2.44 2.00

H DIA 3.00 2.50 Code 00 01 1) 0M W0 1) 10 11 1) 1M W1 1)

A 2.06 1.88 2.06 1.88 2.06 1.88 2.06 1.88 B 1.03 .88 1.03 .88 1.03 .88 1.03 .88

C DIA 1.00 .75 1.00 .75 1.00 .75 1.00 .75 D 2.94 3.00 2.94 3.00 2.94 3.00 2.94 3.00 E 3/8" - 16 UNC x .75 deep M10 x .75 deep 3/8" - 16 UNC - .75 deep M10 x .75 deep K 5/8" - 11 UNC x 1.12 deep M16 x 1.12 deep 1/2" - 13 UNC x .941 deep M12 x .941 deep

1) Max. cam 014 2) P1 + P2 = 7.69 in3/rev max.

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 126662 189723 289375 18246

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

Port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI p = 2000 PSI p = 3500 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI

P1&P2

003 .66 in3/rev 5.14 3.85 2.95 2.11 8.45 13.38005 1.05 in3/rev 8.18 6.86 5.99 2.29 12.00 19.59006 1.30 in3/rev 10.13 8.84 7.94 2.40 14.28 23.57008 1.61 in3/rev 12.55 11.26 10.36 2.54 17.11 28.53010 2.08 in3/rev 16.22 14.93 14.03 2.76 21.38 36.00012 2.26 in3/rev 17.64 16.35 15.45 2.84 23.05 38.92014 2.81 in3/rev 21.88 20.59 19.69 3.09 27.99 47.56017 3.56 in3/rev 27.73 26.44 25.54 3.43 34.81 59.51020 3.89 in3/rev 30.34 29.05 28.15 3.58 37.86 64.85022 4.29 in3/rev 33.43 32.14 31.24 3.76 41.47 71.16025 4.84 in3/rev 37.71 36.42 35.52 4.01 46.46 79.90028 5.42 in3/rev 42.23 40.94 40.321) 4.27 51.74 76.731)031 6.10 in3/rev 47.56 46.27 45.651) 4.58 57.95 86.061)

1) 028 - 031 = 3000 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 26: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

26

ORDERING CODE - T67CB SERIES

Model No. T67CB W - 010 - B10 - 1 R 00 - A 1 - M1 - ..Series - SAE B 2 boltsMounting flange J744Severe duty shaftDisplacement for “P1”Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Displacement for “P2”Volumetric displacement (in3/rev)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51Type of shaft Severe duty shaft (T67CBW only)1 = keyed (non SAE) 2 = keyed (SAE BB)3 = splined (SAE BB)5 = splined (SAE B)

ModificationsMounting w/connection variables11 = 4 bolts SAE flange(J518) UNC threadM1 = 4 bolts SAE flange(J518) Metric threadSeal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67CB - 014 - B03

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Maximum permissible axial load Fa = 180 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P2

P1

P1

P2

55

60

65

70

75

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2800 RPM P1

P1

P1

0

0,5

1

1,5

2

2,5

3

3,5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2800 RPM

P2

P2

P2

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

50

100

150

200

250

300

350

600 1000 1400 1800 2200 2600

F

Fa

Shaft keyed N°1

P1 P2

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Speed n [RPM]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 27: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

6.87

5.75

2.87

3.0

0

.56

DIA

MOUNTING TORQUE 117 ft.lbsMOUNTING TORQUE 45 ft.lbs

3.3

12.8

8

3.0

0

10.46 2.81

3.47 4.00 1.50 .38

.31

.25 MAXI 1.50

4.0

00

3.9

50

DIA

2.0

2D

IA

1.1

11

MA

X

1.0

00

.99

9D

IA.06 x 45°

.06 x 45°

3/8 16 UNC x .75 DEEP - 4 HOLES(M10 x .75 DEEP - METRIC VERSION)

1/2 13 UNC x .94 DEEP - 4 HOLES(M12 x 1.18 DEEP - METRIC VERSION)

3/8 16 UNC x .75 DEEP - 4 HOLES(M10 x .79 DEEP - METRIC VERSION)

T67CBW SHAFT CODE 2

(Keyed SAE B-B)

.06 x 45°

.87

5.8

74

DIA

.96

6M

AX

2.29

1.25

.31

KEY .1875 .1855

SHAFT CODE 1

P1SP2

.50

1.03

.522.00.88

1.00 DIA PRESSURE

2.0

6

1.0

33.5

0

2.50 DIA SUCTION

.75 DIA PRESSURE

1.8

8

.31

.96

1.60

.06 x 45°

1.79.31

.96

.06 x 45°

SHAFT CODE 3SHAFT CODE 3 SAE BB INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 16/32

15 TEETH - 30° PRESSURE ANGLE

SHSHAFT CODE 5AFT CODE 5 SAE B INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/32 13 TEETH - 30° PRESSURE ANGLE

KEY .250 .248

M8 x .63 DEEP

(Keyed no SAE)

C.G.

4.96

DIMENSIONS - Weight : 57.3 Lbs - T67CB SERIES

27

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 126662 189723 289375 18246

- We do not recommand to use this 003 at 4000 PSI & 1500 RPM as the internal is over 50% of theoretical flow.1) 028 - 031 = 3000 PSI max. int. 2) B15 = 4060 PSI max. int.

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

Port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI

P1

003 .66 in3/rev 5.14 3.85 - 2.11 8.45 -005 1.05 in3/rev 8.18 6.86 5.68 2.29 12.00 19.81006 1.30 in3/rev 10.13 8.84 7.63 2.40 14.28 23.79008 1.61 in3/rev 12.55 11.26 10.05 2.54 17.11 28.75010 2.08 in3/rev 16.22 14.93 13.71 2.76 21.38 36.22012 2.26 in3/rev 17.64 16.35 15.14 2.84 23.05 39.14014 2.81 in3/rev 21.88 20.59 19.37 3.09 27.99 47.78017 3.56 in3/rev 27.73 26.44 25.22 3.43 34.81 59.73020 3.89 in3/rev 30.34 29.05 27.84 3.58 37.86 65.07022 4.29 in3/rev 33.43 32.14 30.93 3.76 41.47 71.38025 4.84 in3/rev 37.71 36.42 35.21 4.01 46.46 80.12028 5.42 in3/rev 42.23 40.94 40.321) 4.27 51.74 76.731)031 6.10 in3/rev 47.56 46.27 45.651) 4.58 57.95 86.061)

p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI

P2

B02 .35 in3/rev 2.76 2.31 1.79 0.97 4.53 8.81B03 .60 in3/rev 4.66 4.21 3.69 1.08 6.78 13.64B04 .78 in3/rev 6.09 5.64 5.12 1.17 8.47 17.26B05 .97 in3/rev 7.56 7.11 6.60 1.25 10.22 21.00B06 1.20 in3/rev 9.32 8.87 8.36 1.36 12.30 25.46B07 1.37 in3/rev 10.70 10.25 9.73 1.44 13.93 28.96B08 1.51 in3/rev 11.79 11.34 10.83 1.50 15.23 31.74B09 1.70 in3/rev 13.27 12.82 12.30 1.59 16.97 35.48B10 1.92 in3/rev 14.98 14.53 14.01 1.69 19.00 39.83B11 2.14 in3/rev 16.64 16.19 15.68 1.79 20.97 44.05B12 2.47 in3/rev 19.26 18.81 18.29 1.95 24.07 50.69B14 2.70 in3/rev 21.02 20.57 20.05 2.05 26.16 55.15B15 3.01 in3/rev 23.49 23.04 22.592) 2.20 29.08 57.392)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 28: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T7DB - T7DBS SERIES

Model No. T7DB or T7DBS - B42 - B10 - 1 R 00 - A 1 M1 - ..T7DB series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7DBS series - SAE C 2 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev.)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P2”Volumetric displacement (in3/rev.)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51Type of shaft T7DBS1 = keyed (SAE C) 3 = splined (SAE C)2 = keyed (non SAE) 4 = splined (spec. SAE C)Type of shaft T7DB - T7DBS5 = keyed (ISO 3019-2 - G32M)

ModificationsMounting w/connection variables4 bolts SAE flanges J518

Metric thread UNC threadT7DB - T7DBS T7DBS

M0 M1 00 01P1 1”1/4 1”1/4 1”1/4 1”1/4P2 1” 3/4” 1” 3/4”S 3” 3” 3” 3”

Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7DBS - B31 - B10

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 270 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P2

P2

P1

P1

60

65

70

75

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P1

P1

P1

0

0,5

1

1,5

2

2,5

3

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P2

P2

P2

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

F

Fa

Shaft keyed N°1

28

P1 P2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 29: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 85.1 Lbs - T7DB - T7DBS SERIES

.31

2.17

1.50

.09 x 45°

.31

3.06

1.89

.09 x 45°

B

A 2.44

4.1

9

2.3

1

1.2

50

1.2

48

DIA

1.3

89

MA

X

.09 x 45°

1.50

.31

2.88.62

1.19

P2 S P1P1

C DIA PRESSURE 1.25 DIA PRESSURE3.00 DIA SUCTION

KEY .3126 .3106

1.2

50

1.2

48

DIA

1.3

89

MA

X

1.94

M10 x .79 DEEP

KEY .3126 .3106

.09 x 45°

S D

IA

2.5

3D

IA

e x 45°

.31

.25 MAXI

W1.504.504.31

11.26

2.9

4

2.9

23

.50

3.29

MOUNTING TORQUE 50 ft.lbs MOUNTING TORQUE 138 ft.lbsd

DIA

K

K/2

8.36

( Keyed SAE C )

SSHAFAFTT CODE 2DE 2

SHSHAFAFT COCODEDE 11

SHASHAFT COCODEDE 44 SAE*C Spc INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

14 TEETH - 30° PRESSURE ANGLE

SSHAFAFT COCODEDE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/2414 TEETH - 30° PRESSURE ANGLE

3.2

5

*

7/16 14 UNC x .88 DEEP - 4 HOLESM12 x .88 DEEP - METRIC VERSION

5/8 11 UNC x 1.12 DEEP - 4 HOLESM16 x 1.12 DEEP - METRIC VERSION

3/8 16 UNC x .75 DEEP - 4 HOLESM10 x .75 DEEP - METRIC VERSION

M1

0 x .

79

DE

EP

SSHAFAFT COCODEDE 5

KEY .394 x .315

1.97

3.46

.31

1.2

60

1.2

59

DIA

1.3

78

MA

X

.09 x 45°

( Keyed no SAE ) ( Keyed ISO/R775 - G32M )

C.G.

5.10

29

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 382992 306383 542074 542075 37644

Alternate mounting flange

Series S Dia e x 45° W K d DiaMax. Min.

T7DB 4.921 4.919 .079 .374 7.087 .709T7DBS 5.000 4.998 .051 .500 7.126 .689

Alternate connect. variables00 & M0 01 & M1

A 1.03 .87B 2.06 1.87C 1.00 .75

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

1) 045 = 3500 PSI max. int. 2) 050 = 3000 PSI max. int. 3) B15 = 4060 PSI max. int.

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI

P2

B02 .35 in3/rev 2.76 2.31 1.79 0.97 4.53 8.81B03 .60 in3/rev 4.66 4.21 3.69 1.08 6.78 13.64B04 .78 in3/rev 6.09 5.64 5.12 1.17 8.47 17.26B05 .97 in3/rev 7.56 7.11 6.60 1.25 10.22 21.00B06 1.20 in3/rev 9.32 8.87 8.36 1.36 12.30 25.46B07 1.37 in3/rev 10.70 10.25 9.73 1.44 13.93 28.96B08 1.51 in3/rev 11.79 11.34 10.83 1.50 15.23 31.74B09 1.70 in3/rev 13.27 12.82 12.30 1.59 16.97 35.48B10 1.92 in3/rev 14.98 14.53 14.01 1.69 19.00 39.83B11 2.14 in3/rev 16.64 16.19 15.68 1.79 20.97 44.05B12 2.47 in3/rev 19.26 18.81 18.29 1.95 24.07 50.69B14 2.70 in3/rev 21.02 20.57 20.05 2.05 26.16 55.15B15 3.01 in3/rev 23.49 23.04 22.593) 2.20 29.08 57.393)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 30: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

30

ORDERING CODE - T67DC SERIES

Model No. T67DC W - B42 - 010 - 1 R 00 - A 1 - M1 - ..Series - SAE C 2 boltsMounting Flange J744Severe duty shaftDisplacement for “P1”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P2”Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Type of shaft1 = keyed (SAE C) 3 = splined (SAE C)2 = keyed (non SAE) 4 = splined (spec. SAE C)Type of shaft - Severe duty (T67DCW only)5 = keyed (non SAE)

ModificationsMounting w/connection variables4 bolts SAE flange J518

Metric thread UNC threadM0 M1 00 01

P1 1”1/4 1”1/4 1”1/4 1”1/4P2 1” 3/4” 1” 3/4”S 3” 3” 3” 3”

Seal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67DC - B31 - 022

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Maximum permissible axial load Fa = 270 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P2

P2

P1

P1

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P1

P1

P1

0

1

2

3

4

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P2

P2

P2

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

F

Fa

Shaft keyed N°1

P1 P2

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 31: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

-

7.13

3.56

3.2

5

.69

DIA

MOUNTING TORQUE 138 ft.lbsMOUNTING TORQUE 50 ft.lbs

2.9

23

.50

2.9

4

11.26 8.36

4.31 4.50 1.50 .50

.31

.25 MAXI 1.94

3.29

5.0

00

4.9

98

DIA

2.5

3D

IA

1.3

89

MA

X

1.2

50

1.2

48

DIA

.09 x 45°

.05 x 45°

B

A

.52

2.44

1.22

1.19

.59

4.1

9

2.0

9

2.3

11

.16

.62

.31

2.88

1.50

1.3

89

MA

X

1.2

50

1.2

48

DIA

.09 x 45°

7/16 14UNC x .88 DEEP-4 HOLES( M12 x .88 DEEP - METRIC VERSION )

5/8 11UNC x 1.12 DEEP-4 HOLES( M16 x 1.12 DEEP - METRIC VERSION )

3/8 16UNC x .75 DEEP-4 HOLES(M10 x .75 DEEP - METRIC VERSION )

P2 S P1

3.06

.31

1.89

.09 x 45°

2.17

.31

1.50

.09 x 45°

1.25 DIA PRESSURE

3.00 DIA SUCTION

C DIA PRESSURE

SHAFSHAFT CODE 2T CODE 2

KEY .3126 .3106

M10 x .79 DEEP

SHSHAFT CODE 1AFT CODE 1( Keyed SAE C )

KEY .3126 .3106

M8

x .63 D

EE

P

1.3

74

1.3

73

DIA

1.5

13

MA

X

2.36

.31

3.28

.09 x 45°

T67DCW SHAFT CODE 5 SHAFT COSHAFT CODE 4DE 4

SAE*C Spc INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - 12/24 dp 14 TEETH - 30° PRESSURE ANGLE

SHAFAFT CODE 3T CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

*

KEY .3126 .3106

( Keyed non SAE ) ( Keyed non SAE )

1.0

3

C.G.

5.05

DIMENSIONS - Weight : 85.1 Lbs - T67DC SERIES

31

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 382992 306383 542074 542075 49247

Alternate connect. variables00 & M0 01 & M1

A 1.03 .87B 2.06 1.87C 1.00 .75

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI

P2

003 .66 in3/rev 5.14 3.85 - 2.11 8.45 -005 1.05 in3/rev 8.18 6.86 5.68 2.29 12.00 19.81006 1.30 in3/rev 10.13 8.84 7.63 2.40 14.28 23.79008 1.61 in3/rev 12.55 11.26 10.05 2.54 17.11 28.75010 2.08 in3/rev 16.22 14.93 13.71 2.76 21.38 36.22012 2.26 in3/rev 17.64 16.35 15.14 2.84 23.05 39.14014 2.81 in3/rev 21.88 20.59 19.37 3.09 27.99 47.78017 3.56 in3/rev 27.73 26.44 25.22 3.43 34.81 59.73020 3.89 in3/rev 30.34 29.05 27.84 3.58 37.86 65.07022 4.29 in3/rev 33.43 32.14 30.93 3.76 41.47 71.38025 4.84 in3/rev 37.71 36.42 35.21 4.01 46.46 80.12028 5.42 in3/rev 42.23 40.94 40.322) 4.27 51.74 76.732)031 6.10 in3/rev 47.56 46.27 45.652) 4.58 57.95 86.062)

- We do not recommand to use this 003 at 4000 PSI & 1500 RPM as the internal leakage is over 50 % of theoretical flow.1) 045 = 3500 PSI max. int. 2) 050 - 028 - 031 = 3000 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 32: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T7DD - T7DDS SERIES

Model No. T7DD or T7DDS - B42 - B22 - 1 R 00 - A 1 - M0 - ..T7DD series - ISO 4 bolts 3019-2Mounting flange 125-B4 HWT7DDS series - SAE-C 6 boltsMounting flange J744Displacement for “P1” & “P2”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Type of shaft - T7DDS only1 = keyed (SAE C)2 = keyed (SAE CC)3 = splined (SAE C)4 = splined (SAE BB)Type of shaft T7DD and T7DDS5 = keyed (ISO 3019-2 - G32M)

ModificationsMounting w/connection variables4 bolts SAE flange J518

P1 & P2 = 1”1/4 - S = 4”Type UNC MetricT7DD M0T7DDS 00 M0Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7DDS - B31 - B31

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 180 Lbs

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM P1-P2

P1-P2

P1-P2

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500

115 SUS

60 SUS

P1-P2

P1-P2

F

Fa

Shaft keyed N°1

32

P1 P2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 33: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 123.4 Lbs - T7DD - T7DDS SERIES

1.81

.31

.97

.06 x 45°

8.39

K1

K2

K2

d2DIA

d1 D

IA

4.0

03.5

9

13.69 3.31

5.28 5.84 1.51 w

.31

.25 MAXI

1.94

S D

IA

2.5

3D

IA

1.3

89

MA

XI

1.2

50

1.2

48

DIA

M10 x

.79 D

EE

P

.09 x 45°

e x 45°

.75

4.5

2

2.20

.31

.25 MAXI

.09 x 45°

1.50

1.19

2.3

1

3.06

5.1

3

4.00 DIA SUCTION

1.25 DIA PRESSURE1.25 DIA PRESSURE

2.3

1

6.3

97/16 14UNC x .94 DEEPM12 x .94 DEEP-METRIC VERSION

1.19

5/8 11UNC x 1.18 DEEPM16 x 1.18 DEEP-METRIC VERSION

7/16 14UNC x .88 DEEPM12 x .88 DEEP-METRIC VERSION

.31

3.58

2.00

.09 x 45°

KEY .375 .373

1.6

68

MA

XI

1.5

00

1.4

98

DIA

M10 x

.79 D

EE

P

M10

x .

79 D

EE

P

SHSHAFTAFT COCODE 1DE 1

SHSHAFT COAFT CODE 5DE 5

SHSHAFAFT COCODE 2DE 2

Keyed SAE C

Keyed SAE CC

SHSHAFT COAFT CODE 3DE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHSHAFAFT COT CODE 4DE 4SAE BB INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 16/3215 TEETH - 30° PRESSURE ANGLE

P2 S P1

KEY .394 x .315

1.97

2.68

.39

1.2

61

1.2

60

DIA

1.6

14

MA

XI

Keyed ISO 3019/2 -G32M

MOUNTING TORQUE 140 ft.lbs MOUNTING TORQUE 140 ft.lbs

4.0

0KEY .3126 .3106

7.1

7

C.G.

6.73

33

Alternate mounting flange

Series S DIA e x 45° W K1 d1 DIA K2 d2 DIAMax. Min.

T7DD 4.921 4.919 .079 .374 7.087 .709 4.454 .551T7DDS 5.000 4.998 .059 .500 7.126 .689 4.508 .563

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 382992 635523 542074 317805 40035

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1&P2

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

1) 045 = 3500 PSI max. int. 2) 050 = 3000 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 34: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T7EB - T7EBS SERIES

Model No. T7EB - T7EBS - 042 - B12 - 1 R 00 - A 1 M1 - ..T7EB series - ISO 4 bolts 3019-2Mounting flange 125-A2 HWT7EBS series - SAE-C 2 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)042 = 8.07 057 = 11.18045 = 8.70 062 = 12.00050 = 9.67 066 = 13.00052 = 10.00 072 = 13.86054 = 10.43 085 = 16.40Displacement for “P2”Volumetric displacement (in3/rev)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51Type of shaft T7EB and T7EBS5 = keyed (ISO/R 775 - G38M)Type of shaft T7EBS1 = keyed (SAE CC) 3 = splined (SAE C)2 = keyed (non SAE) 4 = splined (SAE CC)

ModificationsMounting w/connection variables4 bolts SAE flange J518

P1 = 1”1/2 - P2 = 3/4” - S = 3”1/2T7EBS T7EB - T7EBS

Type UNC MetricCode 01 M1Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7EBS 050 - B03

PERMISSIBLE RADIAL LOAD

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

0

1,5

3

4,5

6

7,5

9

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P2

P2

P1

P1

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P1

P1

P1

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

100

150

200

250

300

350

400

450

600 1000 1400 1800 2200

F

Fa

Shaft keyed N°1

34

P1 P2

0

0,5

1

1,5

2

2,5

3

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPMP2

P2

P2

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Maximum permissible axial load Fa = 449 Lbs

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 35: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 121.2 Lbs - T7EB - T7EBS SERIES

8.39

K

K/2

dD

IA

3.0

02

.94

13.06

5.38 4.67 2.06 W

.31

.25 MAX

3.58

2.00

SD

IA

3.0

0D

IA

1.6

68

MA

X

1.5

00

1.4

98

DIA

.09 x 45°

SHAFT SHAFT COCODE 1DE 1( Keyed SAE CC )

e x 45°

3.8

7

4.0

33

.50

MOUNTING TORQUE 138 ft.lbs

MOUNTING TORQUE 50 ft.lbs

2.20

.31

1.50

.09 x 45°

2.45*.31

1.24

.09 x 45°

SHAFSHAFT CODE T CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHAFT COSHAFT CODE 4DE 4 SAE *CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

P1P1SP2P21.8

7

.87

4.7

5

2.3

8

2.75

1.38

2.7

5

1.41

.31

1.50

KEY .313 .311

1.3

89

MA

X

1.2

50

1.2

48

DIA

.09 x 45°

SHASHAFT CODE 2CODE 21.46 DIA PRESSURE

3.50 DIA SUCTION

.75 DIA PRESSURE

C x .75 DEEP - 4 HOLES

B x 1.16 DEEP - 4 HOLES A x .92 DEEP - 4 HOLES

KEY .375 .373

M10 x .79 DEEP

T7EBST7EBS

T7EBT7EB 2.44

(Keyed no SAE )

.09 x 45°

.393.54

1.97

1.6

26

MA

X

SD

IA

1.4

97

1.4

96

DIA

KEY .394 x .315

M10 x .79 DEEP

W

e x 45°

SSHAFAFT CODE 5CODE 5 ( Keyed ISO/R775 - G38M)

C.G.

5.87

35

Alternate mounting flangeS DiaSeries Max. Min. e x 45° W K D Dia

T7EB 4.921 4.919 .079 .374 7.087 .709T7EBS 5.000 4.998 .051 .500 7.126 .689

Alternate connect. variables 01 M1

A 1/2 - 13 UNC M12 B 5/8 – 11 UNC M16 C 3/8 – 16 UNC M10

Shaft torque limits [in3/rev. x bar]Shaft Vi x p max.

1 606732 306383 542074 606735 60673

p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI

P2

B02 .35 in3/rev 2.76 2.31 1.79 0.97 4.53 8.81B03 .60 in3/rev 4.66 4.21 3.69 1.08 6.78 13.64B04 .78 in3/rev 6.09 5.64 5.12 1.17 8.47 17.26B05 .97 in3/rev 7.56 7.11 6.60 1.25 10.22 21.00B06 1.20 in3/rev 9.32 8.87 8.36 1.36 12.30 25.46B07 1.37 in3/rev 10.70 10.25 9.73 1.44 13.93 28.96B08 1.51 in3/rev 11.79 11.34 10.83 1.50 15.23 31.74B09 1.70 in3/rev 13.27 12.82 12.30 1.59 16.97 35.48B10 1.92 in3/rev 14.98 14.53 14.01 1.69 19.00 39.83B11 2.14 in3/rev 16.64 16.19 15.68 1.79 20.97 44.05B12 2.47 in3/rev 19.26 18.81 18.29 1.95 24.07 50.69B14 2.70 in3/rev 21.02 20.57 20.05 2.05 26.16 55.15B15 3.01 in3/rev 23.49 23.04 22.592) 2.20 29.08 57.392)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI P = 2000 PSI P =3500 PSI p =100 PSI p =2000 PSI p = 3500 PSI

P1

042 8.07 in3/rev 62.92 60.37 58.52 8.09 78.44 133.80045 8.70 in3/rev 67.72 65.17 63.32 8.37 84.04 143.60050 9.67 in3/rev 75.38 72.83 70.98 8.82 92.97 159.24052 10.00 in3/rev 78.37 75.82 73.97 8.99 96.47 165.36054 10.43 in3/rev 81.27 78.72 76.87 9.17 99.75 177.46057 11.18 in3/rev 87.12 84.57 82.72 9.51 106.57 189.84062 12.00 in3/rev 93.54 90.99 89.14 9.88 114.17 196.34066 13.00 in3/rev 101.44 98.89 97.04 10.34 123.38 212.46072 13.86 in3/rev 108.00 105.45 103.60 10.72 131.04 225.86085 16.40 in3/rev 127.79 126.131) - 11.88 101.661) -

1) 085 = 1300 PSI max. int. 2) B15 = 4060 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 36: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T67EC SERIES

Model No. T67EC - 085 - 020 - 1 R 00 - A 1 00 - ..

Series SAE-C 2 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)042 = 8.07 057 = 11.18045 = 8.70 062 = 12.00050 = 9.67 066 = 13.00052 = 10.00 072 = 13.86054 = 10.43 085 = 16.40Displacement for “P2”Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Type of shaft1 = keyed (SAE CC)2 = keyed (non SAE)3 = splined (SAE C)4 = splined (SAE CC)

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67EC - 050 - 022

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 449 Lbs

0

1,5

3

4,5

6

7,5

9

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P2

P2

P1

P1

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

8

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P1

P1

P1

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 1000 1400 1800 2200

F

Fa

Shaft keyed N°1

36

P1 P2

0

1

2

3

4

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P2

P2

P2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 170 SUS

Lw = Lp + 8 db (A)

ModificationsMounting w/connection variables4 bolts SAE flange J518

Metric thread UNC threadM0 M1 00 01

P1 1”1/2 1”1/2 1”1/2 1”1/2P2 1” 3/4” 1” 3/4”S 3”1/2 3”1/2 3”1/2 3”1/2

Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 37: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 121.2 Lbs - T67EC SERIES

8.39

7.13

3.56

.69

DIA

MOUNTING TORQUE 138 ft.lbs

2.44.69

.31

1.50

KEY .3125 .3105

1.2

50

1.2

48

DIA

1.3

89

MA

X

.09 x 45°

SHSHAFT CT CODE 2DE 2

SSHAFAFT CODET CODE 11( Keyed SAE CC )

5.0

00

4.9

98

DIA

3.0

0D

IA

1.5

00

1.4

98

DIA

1.6

68

MA

X

.09 x 45°

.05 x 45°

4.0

33

.50

2.9

43

.00

13.06 3.58

5.38 4.67 2.06 .50

.31

.25 MAXI

MOUNTING TORQUE 59 ft.lbs

1.41

.70

2.75

1.381.03

.52

2.0

6

1.0

3

P2P2 S P1P1

1.00 DIA PRESSURE 3.50 DIA SUCTION 1.50 DIA PRESSURE

1/2 13 UNC x .92 DEEP - 4 HOLES(M12 x .92 DEEP -METRIC VERSION )

5/8 11 UNC x 1.16 DEEP - 4 HOLES(M16 x 1.16 DEEP - METRIC VERSION )

SHAFSHAFT CODE 3T CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

SHAFSHAFT CODE 4T CODE 4 SAE CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

2.00KEY .375 .373

3.8

7

M10 x .79 DEEP

2.45.31

3/8 16 UNC x .75 DEEP - 4 HOLES(M10 x .75 DEEP - METRIC VERSION)

1.24

.09 x 45°

2.20.31

1.50

.09 x 45°

( Keyed no SAE )

C.G.

5.87

37

OPERATING CHARACTERISTICS – TYPICAL [115 SUS]

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM Pressure

port Series

Volumetric

displacem. Vi p = 0 PSI p = 2000 PSI p = 3500 PSI p = 100 PSI p = 2000 PSI p = 3500 PSI

042 8.07 in3/rev 62.92 60.37 58.52 8.09 78.44 133.80

045 8.70 in3/rev 67.72 65.17 63.32 8.37 84.04 143.60

050 9.67 in3/rev 75.38 72.83 70.98 8.82 92.97 159.24

052 10.00 in3/rev 78.37 75.82 73.97 8.99 96.47 165.36

054 10.43 in3/rev 81.27 78.72 76.87 9.17 99.75 177.46

057 11.18 in3/rev 87.12 84.57 82.72 9.51 106.57 189.84

062 12.00 in3/rev 93.54 90.99 89.14 9.88 114.17 196.34

066 13.00 in3/rev 101.44 98.89 97.04 10.34 123.38 212.46

072 13.86 in3/rev 108.00 105.45 103.60 10.72 131.04 225.86

P1

085 16.40 in3/rev 127.79 126.13 1) - 11.88 101.66 1) -

p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI

003 .66 in3/rev 5.14 3.85 - 2.11 8.45 -

005 1.05 in3/rev 8.18 6.89 5.68 2.29 12.00 19.81

006 1.30 in3/rev 10.13 8.84 7.63 2.40 14.28 23.79

008 1.61 in3/rev 12.55 11.26 10.05 2.54 17.11 28.75

010 2.08 in3/rev 16.22 14.93 13.71 2.76 21.38 36.22

012 2.26 in3/rev 17.64 16.35 15.14 2.84 23.05 39.14

014 2.81 in3/rev 21.88 20.59 19.37 3.09 27.99 47.78

017 3.56 in3/rev 27.73 26.44 25.22 3.43 34.81 59.73

020 3.89 in3/rev 30.34 29.05 27.84 3.58 37.86 65.07

022 4.29 in3/rev 33.43 32.14 30.93 3.76 41.47 71.38

025 4.84 in3/rev 37.71 36.42 35.21 4.01 46.46 80.12

028 5.42 in3/rev 42.23 40.94 40.32 2) 4.27 51.74 76.73 2)

P2

031 6.10 in3/rev 47.56 46.27 45.65 2) 4.58 57.95 86.06 2)

- We do not recommend to use this 003 at 4000 PSI & 1500 RPM as the internal leakage is over 50% of theoretical flow.1) 085 = 1300 PSI max. int. 2) 028 – 031 = 3000 PSI max.

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 640392 306383 542074 67582

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 38: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T7ED - T7EDS SERIES

Model No. T7ED or T7EDS - 042 - B22 - 1 R 00 - A 1 - M0 - ..T7ED series - 125 A2 HWISO 2 bolts 3019-2 mounting flangeT7EDS series - SAE C 2 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)042 = 8.07 057 = 11.18045 = 8.70 062 = 12.00050 = 9.67 066 = 13.00052 = 10.00 072 = 13.86054 = 10.43 085 = 16.40Displacement for “P2”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Type of shaft T7ED - T7EDS5 = keyed (ISO R775 - G38M)Type of shaft T7EDS1 = keyed (SAE CC) 3 = splined (SAE C)2 = keyed (non SAE) 4 = splined (SAE CC)

ModificationsMounting w/connection variables4 bolts SAE flange J518

P1 = 1”1/2 - P2 = 1”1/4 - S = 4”T7EDS T7ED - T7EDS

Type UNC MetricCode 00 M0Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7EDS - 050 - B31

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 449 Lbs

0

1,5

3

4,5

6

7,5

9

0 500 1000 1500 2000 2500 3000 3500

115 SUS

60 SUS

P2

P2

P1

P1

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

8

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P1

P1

P1

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P2

P2

P2

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

nter

nal l

eaka

ge Q

s [G

PM]

Pow

er lo

ss P

s [H

P]

Load

F [

Lbs]

200

275

350

425

500

575

650

725

800

875

600 1000 1400 1800 2200

F

Fa

Shaft keyed N°1

38

P1 P2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 39: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 145.5 Lbs - T7ED - T7EDS SERIES

8.39

K

K/2

dD

IA

4.0

03

.19

4.0

33

.50

3.8

8

e x 45°

.09 x 45°

SD

IA

3.0

0D

IA

1.6

68

MA

X

1.5

00

1.4

98

DIA

SHAFSHAFT CODE T CODE 1 (Keyed SAE CC )

1.50 KEY .313 .311

1.3

89

MA

X

1.2

50

1.2

48

DIA.09 x 45°

SHAFSHAFTT CODE 2CODE 2

P1P1SP2P2

1.41

.70

3.06

1.53

1.19

.59

2.7

5

5.1

3

2.5

6

2.3

1

1.1

6

14.21

KEY .375 .373

M10 x .79 DEEP

A x .92 DEEP - 4 HOLESB x 1.18 DEEP - 4 HOLES

1.46 DIA PRESSURE4.00 DIA SUCTION1.25 DIA PRESSURE

2.20

.31

1.50

.09 x 45°

SHASHAFT CODE 3T CODE 3 SAE C INVOLUTE SPLINE DATA CLASS 1-FLAT ROOT SIDE FIT

J498b - PITCH 12/24 14 TEETH - 30° PRESSURE ANGLE

C x .94 DEEP - 4 HOLES

MOUNTING TORQUE 138 ft.lbs

5.83 5.26 2.06 W.31

.25 MAXI2.00

3.58

(Keyed no SAE )

2.45

.311.24

.09 x 45°

SHSHAFT CAFT CODE 4DE 4 SAE CC INVOLUTE SPLINE DATA

CLASS 1-FLAT ROOT SIDE FIT J498b - PITCH 12/24

17 TEETH - 30° PRESSURE ANGLE

MOUNTING TORQUE 138 ft.lbs

.09 x 45°

.393.54

1.97

1.6

26

MA

X

SD

IA

1.4

97

1.4

96

DIA

KEY .394 x .315

M10 x .79 DEEP

W

e x 45°

SHAFSHAFT COT CODE 5DE 5 ( Keyed ISO/R775 - G38M)

T7EDT7ED

T7EDST7EDS

1.3

7

2.44

C.G.

6.34

39

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max.

1 640392 306383 542074 606735 60673

Alternate mounting flange

Series S DIA e x 45° W K d DIAMax. Min.

T7ED 4.921 4.919 .079 .374 7.087 .709T7EDS 5.000 4.998 .051 .500 7.126 .689

Alternate connect. variables01 M1

A 1/2” - 13 UNC M12B 5/8” - 11 UNC M16C 7/16” - 14 UNC M12

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P2

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.192) 6.65 85.16 144.192)050 9.64 in3/rev 75.14 72.75 71.563) 7.00 92.09 136.873)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI P = 2000 PSI P =3500 PSI p =100 PSI p =2000 PSI p = 3500 PSI

P1

042 8.07 in3/rev 62.92 60.37 58.52 8.09 78.44 133.80045 8.70 in3/rev 67.72 65.17 63.32 8.37 84.04 143.60050 9.67 in3/rev 75.38 72.83 70.98 8.82 92.97 159.24052 10.00 in3/rev 78.37 75.82 73.97 8.99 96.47 165.36054 10.43 in3/rev 81.27 78.72 76.87 9.17 99.75 177.46057 11.18 in3/rev 87.12 84.57 82.72 9.51 106.57 189.84062 12.00 in3/rev 93.54 90.99 89.14 9.88 114.17 196.34066 13.00 in3/rev 101.44 98.89 97.04 10.34 123.38 212.46072 13.86 in3/rev 108.00 105.45 103.60 10.72 131.04 225.86085 16.40 in3/rev 127.79 126.131) - 11.88 101.661) -

1) 085 = 1300 PSI max. int. 2) 045 = 3500 PSI max. int. 3) 050 = 3000 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 40: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

40

ORDERING CODE - T7EE - T7EES SERIES

Model No. T7EE or T7EES - 066 - 045 - 1 R 00 - A 1 0 - 00 - ..

T7EE series - 250 B4HWISO 3019-2 mounting flangeT7EES series - SAE E 4 boltsMounting flange J744cDisplacement for “P1” & “P2”Volumetric displacement (in3/rev)042 = 8.07045 = 8.70050 = 9.67052 = 10.00054 = 10.43057 = 11.18062 = 12.00066 = 13.00072 = 13.86085 = 16.40Type of shaft T7EE2 = keyed G45N (ISO 3019-2)Type of shaft T7EES1 = keyed (SAE CC)3 = splined (SAE CC)4 = splined (SAE D & E)5 = keyed (SAE D & E)

ModificationsMounting w/connection variables

P1 & P2 = 1”1/2 - S = 4”UNC Metric

T7EE M0T7EES 00 M0Coupling adaptor0 = none2 = SAE B3 = SAE BBSeal class1 = S1 - BUNA N4 = S4 - EPDM5 = S5 - VITONDesign letterPorting combination (see page 62)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7EE 050 - 050

PERMISSIBLE RADIAL LOAD

Pressure p [PSI] Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Double pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 449 Lbs

0

1

2

3

4

5

6

7

8

9

0 500 1000 1500 2000 2500 3000 3500

115 SUS

60 SUS

P1-P2

P1-P2

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]n = 2200 RPM

P1-P2

P1-P2

P1-P2

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

200

275

350

425

500

575

650

725

800

875

600 1000 1400 1800 2200

F

Fa

Shaft keyed N°1

P1 P2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 41: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS & OPERATING CHARACTERISTICS - Weight : 209.4 - T7EE AND T7EES SERIES

41

3.94

.31

2.50

KEY .437 .435

1.9

41

MA

X

1.7

50

1.7

48

DIA

.09 x 45°

3.62

.39

2.48

1.9

09

MA

X

1.7

717

1.7

707

DIA

9.8

43

9.8

40

DIA

.12 x 45°

KEY .551 x .354

8.7

7

.87

DIA

.87 .35

.06 x 45°

P2P2 S P1P1

16.84 2.45

.31

.09 x 45°

8.2

3

2.7

5

1.41

3.06

5.1

32.7

5

5.7

5D

IA

6.8

2

1.50 DIA PRESSURE4.00 DIA SUCTION1.46 DIA PRESSURE

.87 .35

.06 x 45°

3.581.69

6.5

00

6.4

98

DIA

1.6

68

MA

X

1.5

00

1.4

99

DIA

M10 x .79 DEEP

2.50

KEY .375 .373

SHAFAFT CODECODE 11(KEYED SAE C-C)

5.5

04

.11

3.4

13

.87

4.0

04

4.0

02

DIA

COUPLING ADAPTOR

.61

MOUNTING TORQUE 222 ft.lbs

10

.75

10.75

8.84 .81

2.95

.31

1.92

.12 x 45°

MOUNTING TORQUE 65 ft.lbsMOUNTING TORQUE 222 ft.lbs

1.41

1/2 - 13UNC x 1.18 DEEP - 4 HOLES(M12 x 1.18 - METRIC VERSION)

5/8 - 11UNC x 1.18 DEEP - 4 HOLES(M16 x 1.18 - METRIC VERSION)

1/2 - 13UNC x .92 DEEP - 4 HOLES(M12 x .92 - METRIC VERSION)

M12 x 1.10 DEEP

.25

SHAFAFT CODECODE 55(KEYED SAE D&E)

SHAFTSHAFT COCODEDE 22(KEYED G45N-ISO 3019-2)

T7T7EE

SHSHAFT CAFT CODE 33 SAE CC SPLINED SHAFT

CLASS 1- J498b 12/24 D.P. - 17 TEETH

30° PRESSURE ANGLE FLAT ROOT SIDE FIT

SHAFTSHAFT COCODE 44 SAE D & E SPLINED SHAFT

CLASS 1- J498b 8/16 D.P. - 13 TEETH

30° PRESSURE ANGLE FLAT ROOT SIDE FIT

M12 x .94 DEEP

.31

16.02

.31

2.00

8.8

4

1/2 - 13 UNC x .94 DEEP

6.596.22

4.5

34

.65

C.G.

6.69

Shaft torque limits [in3/rev. x PSI]Shaft Vi x p max. Coupling drive Vi x p max.

1 80053 SAE B 182462 101506 SAE BB 289373 1123124 1123125 104818

Code Coupling adaptor0 Without coupling

2 SAE B - 13 teeth - Pitch 16/32Major dia. (min.) .875 - Minor dia. (min.) .753

3 SAE BB - 15 teeth - Pitch 16/32Major dia. (min.) 1.00 - Minor dia (min.) .877

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI P = 2000 PSI P =3500 PSI p =100 PSI p =2000 PSI p = 3500 PSI

P1&P2

042 8.07 in3/rev 62.92 60.37 58.52 8.09 78.44 133.80045 8.70 in3/rev 67.72 65.17 63.32 8.37 84.04 143.60050 9.67 in3/rev 75.38 72.83 70.98 8.82 92.97 159.24052 10.00 in3/rev 78.37 75.82 73.97 8.99 96.47 165.36054 10.43 in3/rev 81.27 78.72 76.87 9.17 99.75 177.46057 11.18 in3/rev 87.12 84.57 82.72 9.51 106.57 189.84062 12.00 in3/rev 93.54 90.99 89.14 9.88 114.17 196.34066 13.00 in3/rev 101.44 98.89 97.04 10.34 123.38 212.46072 13.86 in3/rev 108.00 105.45 103.60 10.72 131.04 225.86085 16.40 in3/rev 127.79 126.131) - 11.88 101.661) -

1) 085 = 1300 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 42: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T67DBB SERIES

Model No. T67DBB - B38 - B14 - B08 - 1 R 00 - B 1 - M1 - ..T67DBB series - SAE C 2 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P2” & P3”Volumetric displacement (in3/rev.)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51Type of shaft1 = keyed (non SAE)2 = keyed (SAE CC)3 = splined 12/24 (SAE C)4 = splined 12/24 (SAE CC)

ModificationsMounting w/connection variablesP1 = 1”1/4 - P2 = 1” - P3 = 3/4” - S = 4”01 = 4 bolts SAE flangeJ518 - UNC threadM1 = 4 bolts SAE flangeJ518 - Metric threadSeal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62 - 63)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

42

P1 P2 P3

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI

P2&P3

B02 .35 in3/rev 2.76 2.31 1.79 0.97 4.53 8.81B03 .60 in3/rev 4.66 4.21 3.69 1.08 6.78 13.64B04 .78 in3/rev 6.09 5.64 5.12 1.17 8.47 17.26B05 .97 in3/rev 7.56 7.11 6.60 1.25 10.22 21.00B06 1.20 in3/rev 9.32 8.87 8.36 1.36 12.30 25.46B07 1.37 in3/rev 10.70 10.25 9.73 1.44 13.93 28.96B08 1.51 in3/rev 11.79 11.34 10.83 1.50 15.23 31.74B09 1.70 in3/rev 13.27 12.82 12.30 1.59 16.97 35.48B10 1.92 in3/rev 14.98 14.53 14.01 1.69 19.00 39.83B11 2.14 in3/rev 16.64 16.19 15.68 1.79 20.97 44.05B12 2.47 in3/rev 19.26 18.81 18.29 1.95 24.07 50.69B14 2.70 in3/rev 21.02 20.57 20.05 2.05 26.16 55.15B15 3.01 in3/rev 23.49 23.04 22.593) 2.20 29.08 57.393)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

1) 045 = 3500 PSI max. int. 2) 050 = 3000 PSI max. int. 3) B15 = 4060 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 43: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

TECHNICAL DATA - T67DBB SERIES

43

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67DBB - B38 - B06 - B04

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Triple pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 270 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P2-P3

P2-P3

P1

P1

60

65

70

75

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P1

P1

P1

0

0,5

1

1,5

2

2,5

3

3,5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM P2-P3

P2-P3

P2-P3

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

F

Fa

Shaft keyed N°1

Pressure p [PSI]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 44: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T67DCB SERIES

Model No. T67DCB - B38 - 028 - B08 - 1 R 00 - B 1 - M1 - ..T67DCB series - SAE C 2 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P2”Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Displacement for “P3”Volumetric displacement (in3/rev)B02 = .35 B07 = 1.37 B12 = 2.47B03 = .60 B08 = 1.51 B14 = 2.70B04 = .78 B09 = 1.70 B15 = 3.01B05 = .97 B10 = 1.92B06 = 1.20 B11 = 2.14

ModificationsMounting w/connection variablesP1 = 1”1/4 - P2 = 1” - P3 = 3/4” - S = 4”01 = 4 bolts SAE flangeJ518 - UNC threadM1 = 4 bolts SAE flangeJ518 - Metric threadSeal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62 - 63)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwiseType of shaft1 = keyed (non SAE)2 = keyed (SAE CC)3 = splined 12/24 (SAE C)4 = splined 12/24 (SAE CC)

44

P1 P2 P3

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI

P3

B02 .35 in3/rev 2.76 2.31 1.79 0.97 4.53 8.81B03 .60 in3/rev 4.66 4.21 3.69 1.08 6.78 13.64B04 .78 in3/rev 6.09 5.64 5.12 1.17 8.47 17.26B05 .97 in3/rev 7.56 7.11 6.60 1.25 10.22 21.00B06 1.20 in3/rev 9.32 8.87 8.36 1.36 12.30 25.46B07 1.37 in3/rev 10.70 10.25 9.73 1.44 13.93 28.96B08 1.51 in3/rev 11.79 11.34 10.83 1.50 15.23 31.74B09 1.70 in3/rev 13.27 12.82 12.30 1.59 16.97 35.48B10 1.92 in3/rev 14.98 14.53 14.01 1.69 19.00 39.83B11 2.14 in3/rev 16.64 16.19 15.68 1.79 20.97 44.05B12 2.47 in3/rev 19.26 18.81 18.29 1.95 24.07 50.69B14 2.70 in3/rev 21.02 20.57 20.05 2.05 26.16 55.15B15 3.01 in3/rev 23.49 23.04 22.593) 2.20 29.08 57.393)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

- We do not recommand to use this 003 at 4000 PSI & 1500 RPM as the internal leakage is over 50 % of theoretical flow.1) 045 = 3500 PSI amx. int. 2) 028 - 031 - 050 = 3000 PSI max. int. 3) B15 = 4060 PSI max. int.

p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI

P2

003 .66 in3/rev 5.14 3.85 - 2.11 8.45 -005 1.05 in3/rev 8.18 6.86 5.68 2.29 12.00 19.81006 1.30 in3/rev 10.13 8.84 7.63 2.40 14.28 23.79008 1.61 in3/rev 12.55 11.26 10.05 2.54 17.11 28.75010 2.08 in3/rev 16.22 14.93 13.71 2.76 21.38 36.22012 2.26 in3/rev 17.64 16.35 15.14 2.84 23.05 39.14014 2.81 in3/rev 21.88 20.59 19.37 3.09 27.99 47.78017 3.56 in3/rev 27.73 26.44 25.22 3.43 34.81 59.73020 3.89 in3/rev 30.34 29.05 27.84 3.58 37.86 65.07022 4.29 in3/rev 33.43 32.14 30.93 3.76 41.47 71.38025 4.84 in3/rev 37.71 36.42 35.21 4.01 46.46 80.12028 5.42 in3/rev 42.23 40.94 40.322) 4.27 51.74 76.732)031 6.10 in3/rev 47.56 46.27 45.652) 4.58 57.95 86.062)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 45: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

TECHNICAL DATA - T67DCB SERIES

45

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67DCB - B38 - 022 - B10

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Triple pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 180 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P1

P2

P1P2

P3

P3

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]n = 2500 RPM

P1

P1

P1

0

1

2

3

4

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]n = 2500 RPM

P3

P3

P3

0

1

2

3

4

5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]n = 2500 RPM

P2

P2

P2

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

F

Fa

Shaft keyed N°1

Pressure p [PSI]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 46: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS - Weight : 134.5 - T67DBB - T67DCB SERIES

1.5

0

2.1

7

.31

.09

x 4

5 °

.09

x 4

5 °

1.2

4

2.4

0

.31

3.355.00

8.3

6

7.1

3

3.5

6

4.00

2.94 2.91

15.9

0

3.3

24.7

05.4

31.5

0.5

0

.31

.25

MA

XI

3.2

9

5.0004.998DIA

2.53DIA

.09

x 4

1.360MAX

1.2501.248DIA

.05

x 4

3.25

MO

UN

TIN

G T

OR

QU

E 5

0 f

t.lb

s

MO

UN

TIN

G T

OR

QU

E 1

38 ft.lb

s

1.87

2.06

.87

1.0

33.0

6

5.13

2.31

1.1

9

1.664MAX

1.5001.499DIA

.09

x 4

M10 x

.79 D

EE

P

2.5

0

3.5

3.6

2

KE

Y .375

.3

73

A x

.88 D

EE

P-

4 H

OLE

SB

x 1

.18 D

EE

P-

4 H

OLE

S

C x

.75 D

EE

P-

4 H

OLE

S

C x

.75 D

EE

P-

4 H

OLE

S

1.0

0D

IA P

RE

SS

UR

E4.0

0D

IA S

UC

TIO

N

1.2

5D

IA P

RE

SS

UR

E

SH

AF

AFT

CT

CO

DE

1D

E1

SH

AFT

SH

AFT

CO

DE

2C

OD

E2

( K

eyed S

AE

CC

)

( K

eyed n

on S

AE

)

SH

AFT

SH

AFT

CO

DE

4C

OD

E4

SA

E C

C IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J498

b -

PIT

CH

12/2

4 1

7 T

EE

TH

- 3

PR

ES

SU

RE

AN

GLE

SH

AF

AFT

CO

TC

OD

E 3

DE

3 S

AE

C IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J498b -

PIT

CH

12/2

4 1

4 T

EE

TH

- 3

PR

ES

SU

RE

AN

GLE

1.9

4K

EY

.250

.2

48

MO

UN

TIN

G T

OR

QU

E 1

38

ft.

lbs

.69DIA

.75

DIA

PR

ES

SU

RE

P3

P2

SP

1

7.0

9

C.G

.

46

Shaf

t tor

que

limits

[in3

/rev

. x P

SI]

Vi x

p m

ax. P

1 +

P2 +

P3

3829

958

902

5420

758

902

Shaf

t1 2 3 4

Alte

rnat

e co

nnec

t. va

riab

les

M1

M12

M16

M10

017/

16”

- 14

UN

C5/

8” -

11 U

NC

3/8”

- 16

UN

C

A B C

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 47: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS - Weight : 134.5 Lbs - T67DCC SERIES

47

8.3

6

7.1

3

3.5

6

MO

UN

TIN

G T

OR

QU

E 1

62

ft.

lbs

2.94 2.91

15

.91

3.2

9

3.3

24

.70

5.4

31

.50

.50

.31

.25

MA

XI

5.0004.998DIA

2.53DIA

1.362MAX

1.2501.248DIA

.09

x 4

.05

x 4

SSH

AF

AFT

CT

CO

DE

DE

11 (

ke

ye

d n

on

SA

E )

.62

3.5

3

.31

2.5

0

KE

Y .

37

5

.3

73

M10 x

.79 D

EE

P 1.664MAX

1.5001.499DIA

.09

x 4

SH

SH

AFT

CO

DE

2A

FTC

OD

E2

( k

eyed S

AE

CC

)

1.1

93

.06

1.0

3B

A

2.31

5.13

2.06

P3

P3

P2

P2

SP

1P

1

1.2

5D

IA P

RE

SS

UR

E1

.00

DIA

PR

ES

SU

RE

CD

IA P

RE

SS

UR

E

4.0

0D

IA S

UC

TIO

N

MO

UN

TIN

G T

OR

QU

E 1

62

ft.

lbs

3/8

16

UN

C x

.7

5 D

EE

P-4

HO

LE

SM

10

x .

75

DE

EP

-ME

TR

IC V

ER

SIO

N3/8

16

UN

C x

.7

5 D

EE

P-4

HO

LE

SM

10 x

.75 D

EE

P-M

ET

RIC

VE

RS

ION

5/8

11

UN

C x

1.1

8 D

EE

P-4

HO

LE

SM

16 x

1.1

8 D

EE

P-M

ET

RIC

VE

RS

ION

7/1

6 1

4U

NC

x .

88

DE

EP

-4 H

OL

ES

M12 x

.88 D

EE

P-M

ET

RIC

VE

RS

ION

2.1

7

.31

1.5

0

.09

x 4

MO

UN

TIN

G T

OR

QU

E 5

9 f

t.lb

s

1.9

4

SH

AS

HA

FTC

OD

E 3

CO

DE

3 S

AE

C IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J4

98

b -

PIT

CH

12

/24

14

TE

ET

H -

30

° P

RE

SS

UR

E A

NG

LE

4.00

5.00 3.35

KE

Y .

25

0

.2

48

3.25

.69DIA

2.4

0

.31

1.2

4

.09

x 4

SSH

AF

AFTT

CO

DE

CO

DE

44 S

AE

CC

IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J4

98

b -

PIT

CH

12

/24

17

TE

ET

H -

30

° P

RE

SS

UR

E A

NG

LE

7.0

9

C.G

.

Shaf

t tor

que

limits

[in3

/rev

. x P

SI]

Vi x

p m

ax. P

1 +

P2 +

P3

3829

958

902

5420

758

902

Shaf

t1 2 3 4

Alte

rnat

e co

nnec

t. va

riab

les

01 &

M1

1.87

4.8

74.7

48

00 &

M0

2.06

31.

031

1.00

0

A B C

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 48: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T67DCC SERIES

Model No. T67DCC - B38 - 028 - 010 - 1 R 00 - A 1 - M1 - ..T67DCC series - SAE C 2 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P2” & “P3”Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Type of shaft1 = keyed (non SAE)2 = keyed (SAE CC)3 = splined 12/24 (SAE C)4 = splined 12/24 (SAE CC)

ModificationsMounting w/connection variables4 bolts SAE flange J518P1 = 1”1/4 - P2 = 1” - S = 4”

UNC MetricP3 = 1” 00 M0P3 = 3/4” 01 M1Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62 - 63)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

48

P1 P2 P3

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.37B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

- We do not recommand to use this 003 at 4000 PSI & 1500 RPM as the internal leakage is over 50 % of theoretical flow.1) 045 = 3500 PSI max. int. 2) 028 - 031 - 050 = 3000 PSI max. int.

p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI

P2&P3

003 .66 in3/rev 5.14 3.85 - 2.11 8.45 -005 1.05 in3/rev 8.18 6.86 5.68 2.29 12.00 19.81006 1.30 in3/rev 10.13 8.84 7.63 2.40 14.28 23.79008 1.61 in3/rev 12.55 11.26 10.05 2.54 17.11 28.75010 2.08 in3/rev 16.22 14.93 13.71 2.76 21.38 36.22012 2.26 in3/rev 17.64 16.35 15.14 2.84 23.05 39.14014 2.81 in3/rev 21.88 20.59 19.37 3.09 27.99 47.78017 3.56 in3/rev 27.73 26.44 25.22 3.43 34.81 59.73020 3.89 in3/rev 30.34 29.05 27.84 3.58 37.86 65.07022 4.29 in3/rev 33.43 32.14 30.93 3.76 41.47 71.38025 4.84 in3/rev 37.71 36.42 35.21 4.01 46.46 80.12028 5.42 in3/rev 42.23 40.94 40.322) 4.27 51.74 76.732)031 6.10 in3/rev 47.56 46.27 45.652) 4.58 57.95 86.062)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 49: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

TECHNICAL DATA - T67DCC SERIES

49

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67DCC - B31 - 022 - 022

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Triple pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 270 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P2-P3

P2-P3

P1

P1

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPMP1

P1

P1

0

0,5

1

1,5

2

2,5

3

3,5

4

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P2-P3

P2-P3

P2-P3

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

Shaft keyed n°1

F

Fa

Shaft keyed N°1

Pressure p [PSI]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 50: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T7DDB - T7DDBS SERIES

Model No. T7DDB or T7DDBS - 050 - B22 - B12 - 1 R 00 - A 1 - M0 - ..T7DDB series - 125-B4 HWISO 4 bolts 3019-2 mounting flange T7DDBS series - SAE C 6 boltsMounting flange J744Displacement for “P1” & “P2”Volumetric displacement (in3/rev.)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P3”Volumetric displacement (in3/rev.)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51Type of shaft T7DDBS1 = keyed (SAE C) 3 = splined 12/24 (SAE C)2 = keyed (SAE CC) 4 = splined 12/24 (SAE CC)Type of shaft T7DDB and T7DDBS5 = keyed (ISO R775 - G38M)

ModificationsMounting w/connection variables4 bolts SAE flange J518c

P1 & P2 = 1”1/4 - S = 4”Type UNC MetricT7DDB - P3 = 1” M0T7DDB - P3 = 3/4” M1T7DDBS - P3 = 1” 00 M0T7DDBS - P3 = 3/4” 01 M1Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62 - 63)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

50

P1 P2 P3

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1&P2

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI

P3

B02 .35 in3/rev 2.76 2.31 1.79 0.97 4.53 8.81B03 .60 in3/rev 4.66 4.21 3.69 1.08 6.78 13.64B04 .78 in3/rev 6.09 5.64 5.12 1.17 8.47 17.26B05 .97 in3/rev 7.56 7.11 6.60 1.25 10.22 21.00B06 1.20 in3/rev 9.32 8.87 8.36 1.36 12.30 25.46B07 1.37 in3/rev 10.70 10.25 9.73 1.44 13.93 28.96B08 1.51 in3/rev 11.79 11.34 10.83 1.50 15.23 31.74B09 1.70 in3/rev 13.27 12.82 12.30 1.59 16.97 35.48B10 1.92 in3/rev 14.98 14.53 14.01 1.69 19.00 39.83B11 2.14 in3/rev 16.64 16.19 15.68 1.79 20.97 44.05B12 2.47 in3/rev 19.26 18.81 18.29 1.95 24.07 50.69B14 2.70 in3/rev 21.02 20.57 20.05 2.05 26.16 55.15B15 3.01 in3/rev 23.49 23.04 22.593) 2.20 29.08 57.393)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

1) 045 = 3500 PSI max. int. 2) 050 = 3000 PSI max. int. 3) B15 = 4060 PSI max. int.

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 51: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

TECHNICAL DATA - T7DDB - T7DDBS SERIES

51

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7DDB - B31 - B31 - B10

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Triple pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 270 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P3

P3

P1-P2

P1-P2

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P1-P2

P1-P2

P1-P2

0

0,5

1

1,5

2

2,5

3

3,5

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM P3

P3

P3

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

F

Fa

Shaft keyed N°1

Pressure p [PSI]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 52: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS - Weight : 145.5 Lbs - T7DDB - T7DDBS SERIES

P1

P1

P2

P2

P3

P3

S

2.4

4

.31

1.2

4

.09

x 4

d2 D

IA

K2

8.3

9

K1

K2

4.00 3.59

2.94

17.9

1

4.7

24.9

25.8

51.5

0W .3

1

.25

MA

XI

S DIA

2.53DIA

1.389MAX

1.2501.248DIA

M10 x .79 DEEP

.09

x 4

ex

45

°

.75

MO

UN

TN

G T

OR

QU

E 5

9 ft.lb

s

4.52

2.2

0

.31

.25

MA

XI

1.5

0

.09

x 4

2.31

1.1

93.0

6

5.13

1.1

9

2.31

7.17

A

B

C D

IA P

RE

SS

UR

E1.2

5D

IA P

RE

SS

UR

E4.0

0D

IA S

UC

TIO

N

1.2

5D

IA P

RE

SS

UR

E

3/8

16U

NC

x .7

5 D

EE

PM

10

x .

75

DE

EP

-ME

TR

IC V

ER

SIO

N

7/1

6 1

4U

NC

x .9

4 D

EE

PM

12 x

.9

4 D

EE

P-M

ET

RIC

VE

RS

ION

5/8

11U

NC

x 1

.18 D

EE

PM

16 x

1.1

8 D

EE

P-M

ET

RIC

VE

RS

ION

7/1

6 1

4U

NC

x .8

8 D

EE

PM

12

x .

88

DE

EP

-ME

TR

IC V

ER

SIO

N

3.5

8

.31

2.0

0

.09

x 4

1.668MAX

1.5001.498DIA

M10 x .79 DEEPKE

Y .

37

5

.3

73

d1 DIA

SSH

AFT

CO

AFT

CO

DE

22 K

eye

d S

AE

CC

SH

AS

HA

FT C

OD

TC

OD

E 11

Ke

ye

d S

AE

C

SH

AS

HA

FT CC

OD

E 4

DE

4 S

AE

CC

IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J49

8b -

PIT

CH

12/2

4 1

7 T

EE

TH

- 3

PR

ES

SU

RE

AN

GL

E

SSH

AFT

CO

AFT

CO

DE

33 S

AE

C I

NV

OL

UT

E S

PL

INE

DA

TA

CLA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J49

8b -

PIT

CH

12/2

4 1

4 T

EE

TH

- 3

PR

ES

SU

RE

AN

GL

E

3.3

1

1.9

4

KE

Y .

31

26

.3

10

6

M10 x .79 DEEP

SSH

AF

AFT

CCO

DE

DE

55

KE

Y .3

94 x

.3

15

.39

Keye

d I

SO

R775 -

G38M

1.2611.260DIA

1.614MAX

1.9

7

2.6

8

MO

UN

TIN

G T

OR

QU

E 1

40 ft.lb

sM

OU

NT

ING

TO

RQ

UE

14

0 ft.lb

s4.00

C.G

.

8.1

3

52

Shaf

t tor

que

limits

[in3

/rev

. x P

SI]

Vi x

p m

ax. P

1 +

P2 +

P3

3829

964

044

5420

758

902

4703

3

Shaf

t1 2 3 4 5

Alte

rnat

e co

nnec

t. va

riab

les

01 &

M1

1.87

4.8

74.7

48

00 &

M0

2.06

31.

031

1.00

0

A B C

Alte

rnat

e m

ount

ing

flang

e

d2 D

ia

.551

.563

K2

4.45

44.

508

d1 D

ia

.709

.689

K1

7.08

77.

126

W .374

.500

e x

45°

.079

.059

S D

ia Min

.4.

919

4.99

8

Max

.4.

921

5.00

0

Seri

es

T7D

DB

T7D

DB

S

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 53: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS - Weight : 145.5 Lbs - T67DDCS SERIES

53

P1

P1

P2

P2

P3

P3

S

2.4

4

.31

1.2

4

.09

x 4

.56

4.51

8.3

9

7.1

3

4.5

1

4.00 3.59

2.94

17.9

1

4.7

24.9

25.8

51.5

0.5

0

.31

.25

MA

XI

5.0004.998DIA

2.53DIA

1.389MAX

1.2501.248DIA

M10 x .79 DEEP

.09

x 4

.05

x 4

.75

MO

UN

TIN

G T

OR

QU

E 5

9 ft.lb

s

MO

UN

TIN

G T

OR

QU

E 1

40 ft.lb

s

MO

UN

TIN

G T

OR

QU

E 1

40 ft.lb

s

4.53

2.2

0

.31

.25

MA

XI

1.4

8

.09

x 4

2.31

1.1

9

3.0

6

5.13

1.1

9

2.31

7.17

A

B

CD

IA P

RE

SS

UR

E

1.2

5D

IA P

RE

SS

UR

E

4.0

0D

IA S

UC

TIO

N 1.2

5D

IA P

RE

SS

UR

E

3/8

16U

NC

x .7

5 D

EE

PM

10

x .

75

DE

EP

-ME

TR

IC V

ER

SIO

N

7/1

6 1

4U

NC

x .

94 D

EE

PM

12

x .

94

DE

EP

-ME

TR

IC V

ER

SIO

N

5/8

11

UN

C x

1.1

8 D

EE

PM

16 x

1.1

8 D

EE

P-M

ET

RIC

VE

RS

ION

7/1

6 1

4U

NC

x .

88 D

EE

PM

12 x

.88 D

EE

P-M

ET

RIC

VE

RS

ION

3.5

8

.31

2.0

0

.09

x 4

1.668MAX

1.5001.498DIA

M10 x .79 DEEP

KE

Y .

375

.37

3

.31

3.3

1 2.3

5

.09

x 4

KE

Y .

31

26

.31

06

1.513MAX

1.3741.372DIA

M10 x .79 DEEP

.69DIA

SH

SH

AFT

CO

AFT

CO

DE

5D

E5

(K

EY

ED

NO

SA

E)

SH

AF

SH

AFT

CO

DT

CO

DE

22 (

KE

YE

D S

AE

CC

)

SH

AF

SH

AFT

CO

DT

CO

DE

11 (

KE

YE

D S

AE

C )

SSH

AF

AFT

CO

DC

OD

E 44

SA

E C

C IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J498

b -

PIT

CH

12/2

4

17

TE

ET

H -

30

° P

RE

SS

UR

E A

NG

LE

SSH

AF

AFT

CO

DC

OD

E 33

SA

E C

IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J498

b -

PIT

CH

12/2

4 1

4 T

EE

TH

- 3

PR

ES

SU

RE

AN

GLE

3.3

1

1.9

4

KE

Y .3

12

6

.3

106

4.00

C.G

.

8.1

3

Shaf

t tor

que

limits

[in3

/rev

. x P

SI]

Vi x

p m

ax. P

1 +

P2 +

P3

3829

964

044

5420

758

902

4924

7

Shaf

t1 2 3 4 5

Alte

rnat

e po

rtC

1.00

0.7

48

B1.

031

.874

A2.

063

1.87

4

Cod

e00

- M

001

- M

1

Port

P3

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 54: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

54

ORDERING CODE - T67DDCS SERIES

Model No. T67DDCS - 050 - B35 - B08 - 1 R 00 - A 1 M0 - ..

Series - SAE C 6 boltsMounting flange J744Displacement for “P1” & “P2”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P3”Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81Type of shaft1 = keyed (SAE C) 4 = splined 12/24 (SAE CC)2 = keyed (SAE CC) 5 = keyed (non SAE)3 = splined 12/24 (SAE C)

ModificationsMounting w/connection variables4 bolts SAE flange J518

P1 & P2 = 1”1/4 - S = 4”Type UNC MetricP3 1” 3/4” 1” 3/4”Code 00 01 M0 M1Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62 - 63)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwise

P1 P2 P3

Pressureport Series Volumetric

Displacement ViFlow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPM

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P1&P2

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 37.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.191) 6.65 85.16 144.191)050 9.64 in3/rev 75.14 72.75 71.562) 7.00 92.09 136.872)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]

- We do not recommand to use this 003 at 4000 PSI & 1500 RPM as the internal leakage is over 50 % of theoretical flow.1) 045 = 3500 PSI max. int. 2) 028 - 031 - 050 = 3000 PSI max. int.

p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI

P3

003 .66 in3/rev 5.14 3.85 - 2.11 8.45 -005 1.05 in3/rev 8.18 6.86 5.68 2.29 12.00 19.81006 1.30 in3/rev 10.13 8.84 7.63 2.40 14.28 23.79008 1.61 in3/rev 12.55 11.26 10.05 2.54 17.11 28.75010 2.08 in3/rev 16.22 14.93 13.71 2.76 21.38 36.22012 2.26 in3/rev 17.64 16.35 15.14 2.84 23.05 39.14014 2.81 in3/rev 21.88 20.59 19.37 3.09 27.99 47.78017 3.56 in3/rev 27.73 26.44 25.22 3.43 34.81 59.73020 3.89 in3/rev 30.34 29.05 27.84 3.58 37.86 65.07022 4.29 in3/rev 33.43 32.14 30.93 3.76 41.47 71.38025 4.84 in3/rev 37.71 36.42 35.21 4.01 46.46 80.12028 5.42 in3/rev 42.23 40.94 40.322) 4.27 51.74 76.732)031 6.10 in3/rev 47.56 46.27 45.652) 4.58 57.95 86.062)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 55: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

TECHNICAL DATA - T67DDCS SERIES

55

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67DDCS - B31 - B31 - 022

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Triple pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 270 Lbs

0

1

2

3

4

5

6

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P3

P3

P1-P2

P1-P2

60

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P1-P2

P1-P2

P1-P2

0

1

2

3

4

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2500 RPM

P3

P3

P3

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

450

600 900 1200 1500 1800 2100 2400

F

Fa

Shaft keyed N°1

Pressure p [PSI]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 56: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T7EDB - T7EDBS SERIES

Model No. T7EDB or T7EDBS - 062 - B35 - B10 - 1 R 00 - A 1 - 01 - ..

T7EDB series - 250-B4 HWISO 4 bolts 3019-2 mounting flange T7EDBS series - SAE E 4 boltsMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)042 = 8.07 057 = 11.18045 = 8.70 062 = 12.00050 = 9.67 066 = 13.00052 = 10.00 072 = 13.86054 = 10.43 085 = 16.40Displacement for “P2”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P3”Volumetric displacement (in3/rev.)B02 = .35 B09 = 1.70B03 = .60 B10 = 1.92B04 = .78 B11 = 2.14B05 = .97 B12 = 2.47B06 = 1.20 B14 = 2.70B07 = 1.37 B15 = 3.01B08 = 1.51

ModificationsMounting w/connection variables4 bolts SAE flanges J518P1 = 1”1/2 - P2 = 1”1/4 - S = 4”Type UNC MetricT7EDB - P3 = 1” M0T7EDB - P3 = 3/4” M1T7EDBS - P3 = 1” 00 M0T7EDBS - P3 = 3/4” 01 M1Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination (see page 62 - 63)00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwiseType of shaft T7EDB1 = keyed (G45N - ISO 3019-2)Type of shaft T7EDBS2 = keyed (SAE D & E)3 = splined 8/16 (SAE D & E)

56

P1 P2 P3

p = 0 PSI p = 2000 PSI p = 4350 PSI p = 100 PSI p = 2000 PSI p = 4350 PSI

P3

B02 .35 in3/rev 2.76 2.31 1.79 0.97 4.53 8.81B03 .60 in3/rev 4.66 4.21 3.69 1.08 6.78 13.64B04 .78 in3/rev 6.09 5.64 5.12 1.17 8.47 17.26B05 .97 in3/rev 7.56 7.11 6.60 1.25 10.22 21.00B06 1.20 in3/rev 9.32 8.87 8.36 1.36 12.30 25.46B07 1.37 in3/rev 10.70 10.25 9.73 1.44 13.93 28.96B08 1.51 in3/rev 11.79 11.34 10.83 1.50 15.23 31.74B09 1.70 in3/rev 13.27 12.82 12.30 1.59 16.97 35.48B10 1.92 in3/rev 14.98 14.53 14.01 1.69 19.00 39.83B11 2.14 in3/rev 16.64 16.19 15.68 1.79 20.97 44.05B12 2.47 in3/rev 19.26 18.81 18.29 1.95 24.07 50.69B14 2.70 in3/rev 21.02 20.57 20.05 2.05 26.16 55.15B15 3.01 in3/rev 23.49 23.04 22.594) 2.20 29.08 57.394)

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI P = 2000 PSI P =3500 PSI p =100 PSI p =2000 PSI p = 3500 PSI

P1

042 8.07 in3/rev 62.92 60.37 58.52 8.09 78.44 133.80045 8.70 in3/rev 67.72 65.17 63.32 8.37 84.04 143.60050 9.67 in3/rev 75.38 72.83 70.98 8.82 92.97 159.24052 10.00 in3/rev 78.37 75.82 73.97 8.99 96.47 165.36054 10.43 in3/rev 81.27 78.72 76.87 9.17 99.75 177.46057 11.18 in3/rev 87.12 84.57 82.72 9.51 106.57 189.84062 12.00 in3/rev 93.54 90.99 89.14 9.88 114.17 196.34066 13.00 in3/rev 101.44 98.89 97.04 10.34 123.38 212.46072 13.86 in3/rev 108.00 105.45 103.60 10.72 131.04 225.86085 16.40 in3/rev 127.79 126.131) - 11.88 101.661) -

1) 085 = 1300 PSI max. int. 2) 045 = 3500 PSI max. int. 3) 050 = 3000 PSI max. int. 4) B15 = 4060 PSI max. int.

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P2

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.192) 6.65 85.16 144.192)050 9.64 in3/rev 75.14 72.75 71.563) 7.00 92.09 136.873)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 57: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

TECHNICAL DATA - T7EDB - T7EDBS SERIES

57

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T7EDB - 062 - B35 - B04

PERMISSIBLE RADIAL LOAD

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Triple pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

Maximum permissible axial load Fa = 449 Lbs

0

1,5

3

4,5

6

7,5

9

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P1

P2

P1

P2

P3

P365

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

100

150

200

250

300

350

400

600 1000 1400 1800 2200

F

Fa

Shaft keyed N°1

Pressure p [PSI]

0

1

2

3

4

5

6

7

8

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P1

P1

P1

0

1

2

3

4

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P3

P3

P3

0

1

2

3

4

5

6

7

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPMP2

P2

P2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 58: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS - Weight : 224.9 Lbs - T7EDB - T7EDBS SERIES

10.75

4.17

4.3

3

10

.75

18

.42

.87

w

3.9

74

.72

1/2

13

UN

C x

.7

9 D

EE

P(M

12

x .

79

DE

EP

- M

ET

RIC

VE

RS

ION

)

2.94

3.9

41

.69

5.2

55.8

44

.72

SDIA

1.941MAX

1.7501.748DIA

.09

x 4

5° 1/2

- 1

3 U

NC

x .

94

DE

EP

SH

AF

SH

AFT

CO

DT

CO

DE

22 (

KE

YE

D S

AE

D &

E )

2.5

0

KE

Y .

43

7

.4

35

4.53

5.50

4.00

.12

x 4

1.9

2

.31

2.9

5

P1

P1

1.4

1

3.0

61.1

9

B

SP

2P

2P

3P

3

8.23

5.13

2.31

2.75

A

1/2

- 1

3 U

NC

x 1

.18

DE

EP

- 4

HO

LE

S(M

12

x 1

.18

DE

EP

- M

ET

RIC

VE

RS

ION

)

5/8

- 1

1 U

NC

x 1

.18

DE

EP

- 4

HO

LE

S(M

16

x 1

.18 D

EE

P-

ME

TR

IC V

ER

SIO

N)

7/1

6 -

14

UN

C x

.94

DE

EP

- 4

HO

LE

S(M

12

x .

94

DE

EP

-ME

TR

IC V

ER

SIO

N)

3/8

- 1

6 U

NC

x .

75

DE

EP

- 4

HO

LE

S(M

10

x .

75

DE

EP

- M

ET

RIC

VE

RS

ION

)

1.5

0D

IA P

RE

SS

UR

E

4.0

0D

IA S

UC

TIO

N

1.2

5D

IA P

RE

SS

UR

E

CD

IA P

RE

SS

UR

E

MO

UN

TIN

G T

OR

QU

E 2

22

ft.

lbs

MO

UN

TIN

G T

OR

QU

E 1

40

ft.

lbs

MO

UN

TIN

G T

OR

QU

E 4

0 f

t.lb

s SS

HA

FTA

FT C

OC

OD

ED

E 33

SA

E D

& E

IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J4

98

b -

PIT

CH

8/1

6 1

3 T

EE

TH

- 3

PR

ES

SU

RE

AN

GL

E

.31

.25

cx

45°

T7

T7E

DB

SE

DB

S

T7E

DB

w

M12 x .94 DEEP

2.4

8

.39

1.7721.771DIA

1.909MAX

SDIA

KE

Y .

55

1 x

.3

54

SSH

AFT

AFT

CO

CO

DE

1D

E1

( K

EY

ED

G4

5N

- I

SO

301

9-2

)

.12

x 4

c x

45°

3.6

2

K

K/2

dD

IA

ZD

IA

45°

C.G

.

6.7

4

58

Shaf

t tor

que

limits

[in3

/rev

. x P

SI]

Vi x

p m

ax. P

1 +

P2 +

P3

1015

0610

4818

1123

12

Shaf

t1 2 3

Alte

rnat

e co

nnec

t. va

riab

les

01 &

M1

1.87

4.8

74.7

48

00 &

M0

2.06

31.

031

1.00

0

A B C

Alte

rnat

e m

ount

ing

flang

e

d D

ia

.866

.811

Z D

ia

12.4

01 -

K -8.

838

W .354

.354

e x

45°

.079

.079

S D

ia Min

.9.

840

6.49

8

Max

.9.

842

6.50

0

Seri

es

T7E

DB

T7E

DB

S

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 59: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

DIMENSIONS - Weight : 224.9 Lbs - T67EDC - T67EDCS SERIES

10.75

4.17

4.3

3

10

.75

18

.42

.87

w

3.9

74

.72

1/2

13U

NC

x .79 D

EE

P(M

12 x

.79 D

EE

P-M

ET

RIC

VE

RS

ION

)

2.94

3.9

41

.69

5.2

55.8

44

.72

SDIA

1.941MAX

1.7501.748DIA

.09

x 4

1/2

- 1

3 U

NC

x .94 D

EE

P

SH

AF

SH

AFT

CO

TC

OD

ED

E 22

( K

EY

ED

SA

E D

& E

)

2.5

0

KE

Y .437

.4

35

4.53

5.50

4.00.1

2x 4

1.9

2

.31

2.9

5

P1

P1

1.4

1

3.0

61.1

9

B

SP

2P

2P

3P

3

8.23

5.13

2.31

2.75

A

1/2

- 1

3 U

NC

x 1

.18 D

EE

P-

4 H

OLE

S(M

12 x

1.1

8 D

EE

P-

ME

TR

IC V

ER

SIO

N)

5/8

- 1

1 U

NC

x 1

.18 D

EE

P-

4 H

OLE

S(M

16 x

1.1

8 D

EE

P-

ME

TR

IC V

ER

SIO

N)

7/1

6 -

14 U

NC

x .94 D

EE

P-

4 H

OLE

S(M

12 x

.94 D

EE

P-M

ET

RIC

VE

RS

ION

)

3/8

- 1

6 U

NC

x .75 D

EE

P-

4 H

OLE

S(M

10 x

.75 D

EE

P-

ME

TR

IC V

ER

SIO

N)

1.4

1D

IA P

RE

SS

UR

E4.0

0D

IA S

UC

TIO

N

1.2

5D

IA P

RE

SS

UR

E

C D

IA P

RE

SS

UR

E

MO

UN

TIN

G T

OR

QU

E 2

22 f

t.lb

s

MO

UN

TIN

G T

OR

QU

E 1

65 ft.lb

s

MO

UN

TIN

G T

OR

QU

E 4

7 f

t.lb

s

SH

AF

AFT

CO

TC

OD

E 33

SA

E D

& E

IN

VO

LU

TE

SP

LIN

E D

AT

A C

LA

SS

1-F

LA

T R

OO

T S

IDE

FIT

J498b -

PIT

CH

8/1

6 1

3 T

EE

TH

- 3

PR

ES

SU

RE

AN

GLE

.32

.25

cx 4

T6

T67

ED

C7E

DC

S

T67

T67

ED

Cw

M12 x .94 DEEP

2.4

8

.39

1.7721.771DIA

1.909MAX

SDIA

KE

Y .55 x

.35

SSH

AF

AFT

CO

DE

CO

DE

11 (

KE

YE

D G

45N

- IS

O 3

019-2

)

.12

x 4

c x

45°

3.6

2

K

K/2

dD

IA

ZD

IA

45°

C.G

.

6.7

4

59

Shaf

t tor

que

limits

[in3

/rev

. x P

SI]

Vi x

p m

ax. P

1 +

P2 +

P3

1015

0610

4818

1123

12

Shaf

t1 2 3

Alte

rnat

e co

nnec

t. va

riab

les

01 &

M1

1.87

4.8

74.7

48

00 &

M0

2.06

31.

031

1.00

0

A B C

Alte

rnat

e m

ount

ing

flang

e

d D

ia

.866

.811

Z D

ia

12.4

01 -

K -8.

838

W .354

.354

e x

45°

.079

.079

S D

ia Min

.9.

840

6.49

8

Max

.9.

842

6.50

0

Seri

es

T7E

DC

T7E

DC

S

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 60: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

ORDERING CODE - T67EDC - T67EDCS SERIES

Model No. T67EDC or T67EDCS - 062 - B35 - 010 - 1 R 00 - A 1 - M1 - ..

T67EDC series - 250-B4 HWISO 4 bolts 3019-2 mounting flange T67EDCS series - SAE EMounting flange J744Displacement for “P1”Volumetric displacement (in3/rev)042 = 8.07 057 = 11.18045 = 8.70 062 = 12.00050 = 9.67 066 = 13.00052 = 10.00 072 = 13.86054 = 10.43 085 = 16.40Displacement for “P2”Volumetric displacement (in3/rev)B14 = 2.64 B31 = 5.94B17 = 3.30 B35 = 6.80B20 = 3.95 B38 = 7.23B22 = 4.29 B42 = 8.26B24 = 4.86 045 = 8.89B28 = 5.39 050 = 9.64Displacement for “P3”Volumetric displacement (in3/rev)003 = .66 017 = 3.56005 = 1.05 020 = 3.89006 = 1.30 022 = 4.29008 = 1.61 025 = 4.84010 = 2.08 028 = 5.42012 = 2.26 031 = 6.10014 = 2.81

ModificationsMounting w/connection variables4 bolts SAE flanges J518

Seal class1 = S1 (for mineral oil)4 = S4 (for the resistant fluid)5 = S5 (for mineral oil and fire resistantfluids)Design letterPorting combination00 = standardDirection of rotation (view on shaft end)R = ClockwiseL = Counter-clockwiseType of shaft T67EDC1 = keyed (G45N - ISO 3019-2)Type of shaft T67EDCS2 = keyed (SAE D & E)3 = splined (SAE D & E)

60

P1 P2 P3

P1 = 1”1/2 - P2 = 1”1/4 - S = 4”Type UNC MetricT67EDC - P3 = 1” M0T67EDC - P3 = 3/4” M1T67EDCS - P3 = 1” 00 M0T67EDCS - P3 = 3/4” 01 M1

OPERATING CHARACTERISTICS - TYPICAL [115 SUS]Pressure

port Series VolumetricDisplacement Vi

Flow qVe [GPM] & n = 1800 RPM Input power P [HP] & n = 1800 RPMp = 0 PSI P = 2000 PSI P =3500 PSI p =100 PSI p =2000 PSI p = 3500 PSI

P1

042 8.07 in3/rev 62.92 60.37 58.52 8.09 78.44 133.80045 8.70 in3/rev 67.72 65.17 63.32 8.37 84.04 143.60050 9.67 in3/rev 75.38 72.83 70.98 8.82 92.97 159.24052 10.00 in3/rev 78.37 75.82 73.97 8.99 96.47 165.36054 10.43 in3/rev 81.27 78.72 76.87 9.17 99.75 177.46057 11.18 in3/rev 87.12 84.57 82.72 9.51 106.57 189.84062 12.00 in3/rev 93.54 90.99 89.14 9.88 114.17 196.34066 13.00 in3/rev 101.44 98.89 97.04 10.34 123.38 212.46072 13.86 in3/rev 108.00 105.45 103.60 10.72 131.04 225.86085 16.40 in3/rev 127.79 126.131) - 11.88 101.661) -

p = 0 PSI P = 2000 PSI P =3630 PSI p =100 PSI p =2000 PSI p = 3630 PSI

P2

B14 2.64 in3/rev 20.54 18.81 17.44 3.23 27.56 47.74B17 3.30 in3/rev 25.68 23.94 22.59 3.53 33.64 58.60B20 3.95 in3/rev 30.82 29.08 27.71 3.84 39.73 69.46B22 4.29 in3/rev 33.43 31.69 30.33 3.99 42.82 74.96B24 4.86 in3/rev 37.85 36.12 34.74 4.25 48.06 84.35B28 5.39 in3/rev 42.04 40.30 38.94 4.50 53.02 93.20B31 5.94 in3/rev 46.32 44.58 43.22 4.75 58.09 102.19B35 6.80 in3/rev 52.98 51.24 49.88 5.15 65.97 116.27B38 7.23 in3/rev 56.35 54.62 53.26 5.35 69.97 123.37B42 8.26 in3/rev 64.34 62.61 61.24 5.82 79.43 140.27045 8.89 in3/rev 69.29 66.90 65.192) 6.65 85.16 144.192)050 9.64 in3/rev 75.14 72.75 71.563) 7.00 92.09 136.873)

- We do not recommand to use this 003 at 4000 PSI & 1500 RPM as the internal leakage is over 50 % of theoretical flow.1) 085 = 1300 PSI max. int. 2) 045 = 3500 PSI max. int. 3) 028 - 031 - 050 = 3000 PSI max. int.

p = 0 PSI p = 2000 PSI p = 4000 PSI p = 100 PSI p = 2000 PSI p = 4000 PSI

P3

003 .66 in3/rev 5.14 3.85 - 2.11 8.45 -005 1.05 in3/rev 8.18 6.86 5.68 2.29 12.00 19.81006 1.30 in3/rev 10.13 8.84 7.63 2.40 14.28 23.79008 1.61 in3/rev 12.55 11.26 10.05 2.54 17.11 28.75010 2.08 in3/rev 16.22 14.93 13.71 2.76 21.38 36.22012 2.26 in3/rev 17.64 16.35 15.14 2.84 23.05 39.14014 2.81 in3/rev 21.88 20.59 19.37 3.09 27.99 47.78017 3.56 in3/rev 27.73 26.44 25.22 3.43 34.81 59.73020 3.89 in3/rev 30.34 29.05 27.84 3.58 37.86 65.07022 4.29 in3/rev 33.43 32.14 30.93 3.76 41.47 71.38025 4.84 in3/rev 37.71 36.42 35.21 4.01 46.46 80.12028 5.42 in3/rev 42.23 40.94 40.323) 4.27 51.74 76.733)031 6.10 in3/rev 47.56 46.27 45.653) 4.58 57.95 86.063)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 61: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

TECHNICAL DATA - T67EDC - T67EDCS SERIES

61

INTERNAL LEAKAGE (TYPICAL)

HYDROMECHANICAL POWER LOSS (TYPICAL)

NOISE LEVEL (TYPICAL)T67EDCS - 062 - B35 - 022

PERMISSIBLE RADIAL LOAD

Triple pump noise level is given with each section dischargingat the pressure noted on the curve.

Total hydromechanical power loss is the sum of each section atits operating conditions.

0

1,5

3

4,5

6

7,5

9

0 500 1000 1500 2000 2500 3000 3500 4000

115 SUS

60 SUS

P1

P2

P1 P2

P3

P3

65

70

75

80

0 500 1000 1500 2000 2500 3000 3500

Série1Série2

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

u = 150 SUS

Lw = Lp + 8 db (A)

Do not operate pump more than 5 seconds at any speed or vis-cosity if internal leakage is higher than 50% of theoretical flow.Total leakage is the sum of each section loss at its operatingconditions.

100

150

200

250

300

350

400

600 1000 1400 1800 2200

F

Fa

Shaft keyed N°1

01

23

45

67

89

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM P1

P1

P1

01

234

56

0 500 1000 1500 2000 2500 3000 3500 4000

n = 1200 RPM

n = 1800 RPM [115 SUS]n = 2200 RPM

P3

P3

P3

012345678

0 500 1000 1500 2000 2500 3000 3500

n = 1200 RPM

n = 1800 RPM [115 SUS]

n = 2200 RPM

P2

P2

P2

Pressure p [PSI]

Pressure p [PSI]

Lp. N

oise

leve

l [db

(A)]

1 m

ISO

441

2

Speed n [RPM]

Maximum permissible axial load Fa = 449 Lbs

Inte

rnal

leak

age

Qs

[GPM

]Po

wer

loss

Ps

[HP]

Load

F [

Lbs]

Pressure p [PSI]

Pe = 13 PSI abs

n = 1200 RPM

n = 1800 RPM

υ = 150 SUS

Lw = Lp + 8 db (A)

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 62: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

62

PORTING DIAGRAMS - GENERAL CATALOG

T7BB/T7BBS

T6CC

T67CB

T7DB/T7DBS

T67DC

T7EB/T7EBS

T67EC

T7DD/T7DDS

T7ED/T7EDS

T7EE/T7EES

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

P1-P2 S-P1-P2P1-P2 P1-P2 P1 P1 P1 P1-S

S

P2

S-P2

S

P2

P1-S P1-S P1 P1 P1 P1 P1 P1

P2 P2

S

SP2

P2

S

P2

S

P2

S

P2

P2S

P2

S

S

S

16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31

P1 P1 P1 P1 P1 P1

P1-S P1-S P1 P1 P1 P1

P1 P1

P1-S P1-S

S S S S

S S S S

P2

P2

P2 P2

P2

P2

P2

P2

P2 P2

P2

P2

P2 P2

P2 P2

S S S S

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

P1-P2 S-P1-P2P1-P2 P1-P2 P1 P1 P1 P1-S

S

P2

S-P2

S

P2

P1-S P1-S P1 P1 P1 P1 P1 P1

P2 P2

S

SP2

P2

S

P2

S

P2

S

P2

P2S

P2

S

S

S

T67DBB

T67DCB

T67DCC

T7DDB/T7DDBS

T67DDCS

T7EDB/T7EDBS

T67EDC/T67EDCS

P1-P2-P3

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31

32 33 34 35 36 37 38 39

40 41 42 43 44 45 46 47

48 49 50 51 52 53 54 55

56 57 58 59 60 61 62 63

S-P1-P2-P3P1-P2-P3

S

S

P1-P2-P3

S

P1 P1 P1 P1-S

S

P2

P3

S-P2-P3

S

P2

P3

P2

P1-S P1-S P1 P1-P2 P1-P2 P1-P3 P1 P1-P3

S-P1-P2 S-P1-P2S-P1-P2 S-P1-P3 S-P1-P3 S-P1-P3 P1-P2 P1

P1 P1 P1 P1-P3 P1-S P1-S P1-S P1-S

P1-S P1-P2P1-S P1-P2 P1-P2 P1-P2 P1-P2 P1-P2

P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1-P3 P1 P1

P1 P1 P1 P1P1 P1 P1 P1

P1 P1 P1 P1P1 P1 P1 P1

P2

P2

P3

P2-P3 P2-P3

S

S-P2

P2

P2

P3

S

S

P2

S

P2

P2

P3

P2-P3

S

P3

P3

P3

P3

S

P2

S

P2

P3

P2

P3

S

P3

S

S

S-P3

P2

P3S

P2

P3 P3

P2

P2

P3

P3

P2

P2

P2P3 P3

P3 P3 S S

S SP3

P3S SP3 P3

S S

P2 P2 S S

P2

P2

P2

P2S S

P3

S

P2 S

P2P3

P2

S

P3

P2

S

P3

S-P2 S-P2 S-P3 S-P3 P3

P3

P3

P2

P2

S

P2

P3

S

P2

S

P3

P2

S

P3

P2 P2

P3S

P2

P3 P3 P2S S

S

P3

P2

S

P2

P2

P3

SP3

Parker HannifinDenison Vane Pump DivisionVierzon - France

Page 63: Vane pumps General catalog Single, double & triple … · Vane pumps General catalog Single, double & triple T7 - T67 - T6C series ... B31 5.94 3000 4350 B35 6.80 B38 7.23 2800 4060

PORTING DIAGRAMS - GENERAL CATALOG

63

64 65 66 67 68 69 70 71

72 73 74 75 76 77 78 79

80 81 82 83 84 85 86 87

88 89 90 91 92 93 94 95

96 97 98 99 1A

P1 P1 P1 P1P1 P1 P1 P1

P1 P1 P1 P1 P1-P2 P1-P2 P1-P2 P1-P2

1B 1C 1D

1E 1F 1G 1H 1J 1K 1L 1M

1N 1P 1R 1S 1T 1U 1V 1W

1X 1Y 1Z 2A 2B 2C 2D 2E

P1 P1 P1 P1P1 P1 P1 P1

P1 P1 P1 P1 P1-P2 P1-P2 P1-P2 P1-P2

P1-S P1-S P1-S P1-S P1-S P1-S P1-S P1-S

P1-S P1-S P1-S P1-S P1-S-P2 P1-S-P2 P1-S-P2 P1-S-P2

P1 P1 P1 P1P1 P1 P1 P1

P1 P1 P1 P1 P1-P2 P1-P2 P1-P2 P1-P2

P2

P3

S

P2

P3

S S S S-P2 S-P2 S-P2 S-P2P3 P3

P3 P3

P3 P3

P2 P2

S S S S S S S S

P2 P2 P2 P2

P3 P3

P3 P3

P3 P3

P3 P3

S

P2

S

P2

S

P2

S

P2S S S S

P2 P2 P2 P2

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

SS

S S SP2

S

P2

S

P2

S

P2

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P3 P3

P2 P2 P2 P2

P2 P2 P2 P2

P2 P2 P2 P2

P2P2

S

P2

S

P2

SS S S S S

P2 P2 P2 P2

S

P2

S

P2

S

P2

S

P2 S S S S

T67DBB

T67DCB

T67DCC

T7DDB/T7DDBS

T67DDCS

T7EDB/T7EDBS

T67EDC/T67EDCS

02 16 17 18

19 07 28 32

01 22 34 38

13 04 46 47

00 36 11 37

42 24 53 60

03 39 35 12

44 26 61 56

20 30 08 31

21 33 29 09

40 48 10 58

45 49 59 23

27 51 05 50

43 62 52 25

41 63 14 57

15 54 55 06

S P2 P3 P2 P3

P1

Parker HannifinDenison Vane Pump DivisionVierzon - France