4
UTS Mass Personnel & Patient Decontamination System (MP&P DECON) UTS Systems, LLC 36 Tupelo Ave SE ∙ Ft. Walton Beach, Florida 32548 [email protected] ∙ www.uts-systems.com CAGE 76EK8 ∙ 850.226.4301

UTS Mass Personnel & Patient Decontamination System · UTS “Single Skin” Shelters Highlights • Containment berm integral to floor • Hanging System to dry suits/boots • Electrical

  • Upload
    vunhi

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

UTS Mass Personnel & Patient Decontamination System

(MP&P DECON)

UTS Systems, LLC36 Tupelo Ave SE ∙ Ft. Walton Beach, Florida 32548

[email protected] ∙ www.uts-systems.comCAGE 76EK8 ∙ 850.226.4301

UTS “Single Skin” Shelters

Highlights

• Containment berm integral to floor• Hanging System to dry suits/boots• Electrical & Hoses housed in

vertical/horizontal raceways• Coiled sprayers for mixed solution & rinse and

overhead spray bars• Specially designed floor risers allow flow to

sump pump & reduce slippage

• Chem Bio resistant barrier simplifies logistics • Improved throughput using filtered force air flow

and specialized flooring• Compatible with Col Pro or standalone- DUAL USE• Shelter sleeve drop for quick removal of

contaminated garments from interior of shelter

• Provides smooth processing for Non-Ambulatory Patients

• Secure locking, adjustable legs and leveling indicator

• Anodized aluminum rollers, nylon rod with stainless steel axle nuts– RUST FREE

Litter Conveyor

Vapor Hazard Area/Staging

DECON AREA/Anteroom

• Containerized dual on-demand diesel water heaters

• Allows for water to be drawn from: Self contained 3,000 gallon tank Pressurized feed from fire hydrant Open source through inlet strainer

• Variable solution injection system

DECON Water Heater

Waste Sump Pump

• Robust run-dry sump powered by DECON Water Heater’s control panel

• Suction head reduces required space in shelter through one of four entry sleeves

• Ships securely inside container along with all hoses and associated equipment

• Chemical permeability live agent 72 hour testing against HD, GB, GD and Vx.

• Chamber Testing successfully completed including:- Over Pressure, Leakage, & Complexing- Airlock Purge (3-log reduction) - Static Vapor Challenge Test – Simulant:(Trimethyl Phosphate simulant for Sarin)- Static Particulate Challenge Test (SPCT) Simulant: BG (Bacillus subtilis simulantfor Anthrax)

• Concept Demonstration Evaluation with twelve (12) Shelters, Latrines (CPEL), & Multi-Personnel (MPE) Entry Airlocks

“Single Skin” Testing

UTS MP&P DECON

Layout

• Suggested Layout Includes: Two (2) UTS TM60 Tall “Single Skin”

Shelters complete DECON Water Heater and Waste

Sump Pump with Contaminant Berm 3,000 Supply and Waste Bladders Double Entry Hard Doors Lights & Power Distribution Panels Unique Riser Flooring System Specially designed shipping

containers for easy packaging

• Throughput: Configurable--estimated 75 personnel

per hour including non-ambulatory patients

Could double or triple capacity with 3-lines of non-ambulatory

• Cost: MP&P is scalable and modular and price ranges from $130K to $240K (please see following price sheets)