Commands Moshell (site name/RNC name) lt all lst cell ala lga lgs lga -m 24h lgs -m 24h ter | grep -i error ter | grep -i Fault ter | grep -i Failure te log read st Rax st TX st E1 Invh cvls lga lge lgv lgs lgu lgo lgy gl – lgh lgd lgx lgu lh ru fui get vswr lh ru fui get devstat lh ru fui get Fault cabx cab get 0 bo Invh Rax/Tx pget E1 cedh -r iub_ORNEK(Iub of the Cedr Cedh get utrancell uarfcndl lhsh 000800 te log read

Useful Moshell Commands

Embed Size (px)

Citation preview

Page 1: Useful Moshell Commands

Commands Moshell (site name/RNC name)

lt alllst cell

alalgalgslga -m 24hlgs -m 24h ter | grep -i error ter | grep -i Fault ter | grep -i Failurete log read st Raxst TXst E1Invhcvls

lgalgelgvlgslgulgolgygl –lghlgdlgxlgulh ru fui get vswrlh ru fui get devstatlh ru fui get Fault

cabxcabget 0boInvh Rax/Txpget E1cedh -r iub_ORNEK(Iub of the site)CedrCedh get utrancell uarfcndl

lhsh 000800 te log read

Page 2: Useful Moshell Commands

lget utrancell=ORNEK11 utranrelat lget utrancell=ORNEK11 gsmrelatiget rbslocalcell

Pmr -m 1get ORNEK scram cedr | grep ORNEK(ORNEK is site

get . maxdlget . attenget TMALicense serverlgsavemo | grep cell name get utrancell uarfcnul

get iurlink get utrancell=ORNEK oper lst ORNEK(site name)

Pgets . object name/counter nameRLDEP:Cell=all,extRLUMP:cell=all;rlnrp:cell=all,utran;RLSUP:cell=allRLLOP:cell=allMGORP:RNC=ALLMGOCP:cell=allMGRIP:RNC=alluerget . noOfRadioLinksst all dishlpr utrancell=cellname

lhsh 000800 te log read | grep ERROR

Pmx -m 2 aal2ap=b265 pmUnSuccOutConnsRemoteQosClass

Page 3: Useful Moshell Commands

Descripition Levellog in to RNC or site name(Use winfoil to connect) Node B

To load all the Mo (you shoul load all the commands befor running any command) Node Blist all the cell Node B

No of active Alarms Node BAlarm history Node BComplete history of site Node BAlarm history for last 24 hours(Transmission errors) Node Bcheck for Hardware crashes on site Node BError fault and failure at node B( | is pipe used in UNIX) Node BError fault and failure at node B( | is pipe used in UNIX) Node BError fault and failure at node B( | is pipe used in UNIX) Node BFind exception and events at Node BStatus of RAX card Node BStatus of tx card Node BStatus of E1/T1 Node Bcheck license and Feature on the site Node Bcheck software version Node B

– alarm log Node B

– event log Node B

– availability log Node B

– system log Node B

– upgrade log Node B

– command log (i.e. when someone has done an action, create delete or set on a MO) Node B

– security log Node B

COLI log (i.e. anything typed in from moshell COLI) Node B

– HILI log Node B

– node restarts and downtime Node B

– alarms on specific dates Node B

– upgrade log (for SW upgrades) Node BVSWR for all the port Atorization required Node BDevice stat Node BFault Node B

Board configuration(can get u Port number which can be used for VSWR) Node B

Board configuration Node BNode B type Node BNo of boards and slot position in node B Node BS/w version Channel elment Node BErrors in second at E1 does not work for IP sites Node B-> CE Usage RNCCheck Code utilization for RNC RNCcheck channel elemnet utilization for RNC RNC-> DL FREQUENCY CHECK RNC

To Read error on Board (00800 is boart port obtained from BO command) Node B

Page 4: Useful Moshell Commands

Add pipe to receive only error message Node Butran neighbour RNCGSM neighbour RNClist of cell including all parameters at RBS level Node B

To check Performance followed by choice to get desired KPI( 1 stands for last one hour) RNC/Node BScrambling code RNC-> INSTANT SITE TRAFFIC AND POWER CONSUMPTION RNC

Maximum Downlink power capability(space after get and space after .) Node BFeeder attentuation Node Bget TMA Node BCheck license server status on the site Node BTracking changes done on cell RNC-> UL FREQUENCY CHECK RNC

Iub congestion RNCIur link RNCoperational status of site RNClist all mo and their state RNC

to check particular object type is activated or not RNCcheck particular cell is defined as a external cell in BSC BSCcheck scrambling code defined per cell BSCall external neighbour defined in BSC BSCcell reselection parameter to WCDMA BSCISHLOV and other parameters BSCexternal RNC definition MSCexternal cell definition in MSc MSCinternal RNC definition MSCno of calls in RNC RNCno of active radio links in RNC Node Bdisabled MO in Node B Node Bdisplay all commands Node B/AlarmsNeighbour check

Page 5: Useful Moshell Commands

categorayConnect to RNC/Utrancell

Basic checkcell status

AlarmsAlarmsAlarmsAlarmsAlarmsAlarmsAlarmsAlarmsErrorBasic checkBasic checkBasic checkBasic checkBasic check

Node B logs

Node B logs

Node B logs

Node B logs

Node B logs

Node B logs

Node B logs

Node B logs

Node B logs

Node B logs

Node B logs

Node B logsVSWR configurationAlarms

configuration

configurationconfigurationconfigurationconfigurationE1 performanceCE usageChannel elmenet and Code usageChannel elmenet and Code usageDLARFCN

Error on boards

Page 6: Useful Moshell Commands

Error on boardsNeighbour relationshipNeighbour relationshipParameter

PerformanceScrambling codeSite tarffic

TMA attenuationTMA attenuationTMA attenuationBasic checkTracking changes on cellULARFCN

Basic checkBasic checkBasic checkBasic check

Object type activation checkWCDMA neighbours in GSMWCDMA neighbours in GSMWCDMA neighbours in GSMWCDMA neighbours in GSMWCDMA neighbours in GSMWCDMA neighbours in GSMWCDMA neighbours in GSMWCDMA neighbours in GSMno of callsno of active radio liksBasic checkinfoNeighbour relationship

Page 7: Useful Moshell Commands
Page 8: Useful Moshell Commands