27
4 th floor, 5 Marshala Zhukova St., Ekaterinburg, 620014 Tel/fax: +7 (343) 310-04-40 E-mail: [email protected] www.uztt.ru UZTT branch office addresses: office 113,. 54 Karla Marksa St., Chelyabinsk, 454091 Tel/fax: +7 (351) 240-02-84 E-mail: [email protected] www.ural-zavod.ru office 343, 35 Kommunisticheskaya St., Novosibirsk, 630007 Tel/fax: +7 (383) 249-32-82 E-mail: [email protected] www.uztt-nsk.ru room 6-N, 23 letter А Vladimirsky avenue, Saint-Petersburg, 191002 Tel/fax: +7 (812) 600-36-31 E-mail: [email protected] www.uztt-spb.ru Moscow, tel. +7 (495) 661-31-01 Factory-Assembled Switchgear Cells Of One-Sided Maintenance KSO-292 Series Ural Company for Transformer Technologies, LLC Ural Company for Transformer Technologies, LLC

Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

4th floor, 5 Marshala Zhukova St., Ekaterinburg, 620014

Tel/fax: +7 (343) 310-04-40E-mail: [email protected]

www.uztt.ru

UZTT branch office addresses:

office 113,. 54 Karla Marksa St., Chelyabinsk, 454091

Tel/fax: +7 (351) 240-02-84E-mail: [email protected]

www.ural-zavod.ru

office 343, 35 Kommunisticheskaya St., Novosibirsk, 630007

Tel/fax: +7 (383) 249-32-82E-mail: [email protected]

www.uztt-nsk.ru

room 6-N, 23 letter А Vladimirsky avenue, Saint-Petersburg, 191002

Tel/fax: +7 (812) 600-36-31E-mail: [email protected]

www.uztt-spb.ru

Moscow, tel. +7 (495) 661-31-01

Factory-Assembled Switchgear Cells Of One-Sided Maintenance

KSO-292 Series

Ural Company for Transformer Technologies, LLC

Ural Company for Transformer Technologies, LLC

Page 2: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

1

ww

w.u

ztt.

ru

Ural Company for Transformer TechnologiesThe UZTT Company is specialized in manufacturing of low-voltage and high-voltage equipment for electrical power supply systems used in industrial and civil construction, agriculture, oil and gas industries, and mining operations.

Since 2000 the UZTT transformer factory for high-voltage equipment has its own manufactur-ing of Package Transformer Substations, transformers and sells its products directly from the factory.

The UZTT manufacturing factory offers the following range of services:

• Designing of KTP substations;• Complete cycle of electrical equipment manufacturing;• Mounting of package transformer substations, electrical installation work, substations

construction and subsequent installation;• Manufacturing of oil-cooled power transformers and other components for substations;• Selling of finished electrical equipment, available and upon request.

Such a full scope of works gives our customers actual opportunity to reduce costs (both finan-cial and temporal) for project implementation as a whole, as it eliminates the need to look for different design, manufacturing and installation companies.

We constantly improve the technological process and search for non-conventional solutions which allow to adapt to changing market conditions. The company is developing new mod-el forms of transformer KTP substations, extending its product lines and equipment power range. Being targeted at market requirements, the factory manufactures 14 varieties of pack-age transformer substations with power of 25 - 2500 kVA, high voltage of 6 kV or 10 kV/ low voltage НН 0,4 kV or 0,23 kV.

All products of the factory are certified and comply with GOST and TU national standards. Prod-ucts go through stringent quality control.

Since July 2008 the UZTT plant has been an official supplier for the Ekaterinburg Electric Grid Company. We offer our regular customers different ways of work: credit on goods, deferred pay-ments, and customer-friendly system of discounts.

Being committed to the principle “the customer comes first”, the highly skilled engineers and technicians of the UZTT, LLC use a professional approach in their solutions, placing high qual-ity of customer service as a priority in their operations.

Our objective is a long-term and mutually beneficial cooperation. The distinguishing feature of our products is good value for money. This aspect is highly appreciated by our regular partners, having contributed to our today’s success and our future prospects for its amplification.

We’ll be glad to cooperate with You!

Page 3: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

2

ww

w.u

ztt.

ru

Table оf Contents

General information

Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Structure of KSO cells identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Structure of main circuit identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Table 1. Main circuit diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Table 2. Main technical data of KSO cells . . . . . . . . . . . . . . . . . . . . . .13

Table 3. KSO chamber classification . . . . . . . . . . . . . . . . . . . . . . . . . .14

Main built-in equipment, used for primary connections . . . . . . . . . .14

Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Table 4. Busbar bridge types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Scope of supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Table 5. Secondary circuit diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Questionnaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Certificate of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Page 4: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

3

ww

w.u

ztt.

ru

General InformationCertificate No. ROSS RU.AI50.V06884 (РОССRU.АИ50.В05884)

Function

KSO-292 series factory-assembled switchgear cells of one-sided maintenance with nominal voltage of 6 and 10 kV, 50 Hz three-phase DC are designed for grid switching equipment with insulated-neutral conductor or neutral conductor,grounded via arc blowout.

Structure of KSO cells identification

Structure of main circuit identification(the given identifications are used in diagram tables – pp. 4-12)

Х – index number of main circuit diagram;

X – letter identification:

Pо – PPO-10spring drive; E – PE-11 electromagnetic drive; EV – VVTE-M 10 vacuum switch with in-built electromagnetic drive.

A – automatic switching;

X – nominal cell power, A (400, 600, 1000, 1600);

X – letter identification:

TSN – three-phase power transformer (25 or 40 kVA); TN – voltage transformer; RVO, RVR – charge neutralizer type; OPN – voltage suppressor.

Operating conditions:• Altitude above the sea level – not more than 1000 m;

• Lower ambient air temperature limit: - 25 C;

• Higher effective value ambient air temperature 35 C;

• Non-explosive environment, containing no current-conducting dust, aggressive gases and vapors, depleting metal parts and insulation.

К SО - 292 - Х - UХLХCellFactory-assembledOf one-sided maintenance 1992 modification

Main circuit diagram identification

Climatic modification and placement category (3.4) according to GOST 15150-69 and GOST 15543-70

Page 5: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

4

ww

w.u

ztt.

ru

*OP

N-K

S-1

0 t

ype

volt

age

supp

ress

ors

are

inst

alle

d in

KS

O-E

G c

ells

on

requ

est

Ope

ratio

nal b

lock

ing:

Y1,Y

2 –

ear

thin

gdis

conn

ecto

r blo

ck-lo

ckS

q1, S

Q2

– e

arth

ingd

isco

nnec

tor b

lock

con

tact

s

Tab

le 1

. Ma

in c

ircu

it d

iag

ram

s

Mai

n K

SO

cel

l cir

cuit

diag

ram

s

12

12

.1-6

00

TN

Cel

l wit

h vo

ltag

e tr

ansf

orm

er

11

11-

40

01

1-6

00

Cel

l wit

h lo

ad-b

reak

sw

itche

s

10

10

-40

01

0-6

00

9

9-4

00

Cel

l wit

h

pow

er fu

se

8

8P

O-6

00

8E-

60

08

PO

-10

00

8E-

10

00

8E

V-6

00

8E

V-1

00

08

EV-

60

0 O

PN

8E

V-10

00

OPN

Cel

ls w

ith

high

-vol

tage

sw

itche

s

6

6P

O-6

00

6E-

60

06

PO

-10

00

6E-

10

00

6E

V-6

00

6E

V-1

00

06

EV-

16

00

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

2

2P

O-6

00

2E-

60

02

EV-

60

02

EV-

60

0 O

PN

1

1P

O-6

00

1E-

60

01

EV-

60

0 1

EV-

60

0 O

PN

Mai

n

circ

uit

diag

ram

Dia

gram

nu

mb

er

Indi

catio

n of

m

ain

circ

uit d

i-ag

ram

impl

e-m

enta

tion

KS

O c

ell n

ame

(acc

ordi

ng

to m

ain

co

mpo

nent

pa

rts)

Page 6: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

5

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l cir

cuit

diag

ram

s

19

19

-60

0TN

19

-10

00

TN1

9-1

60

0TN

Cel

l wit

h vo

ltag

e tr

ansf

orm

ers

18

18

-60

0TN

18

-10

00

TN1

8-1

60

0TN

16

16

-40

0TS

N2

51

6-4

00

TSN

40

Cel

l wit

h au

xilia

ry tr

ansf

orm

ers

15

15

-40

0TS

N2

51

5-4

00

TSN

40

14

14

.1-4

00

RVO

14

.1-4

00

OP

N1

4.1

-40

0R

VRD

Cel

ls w

ith

char

ge n

eutr

aliz

ers

or v

olta

ge

supp

ress

ors

and

con

dens

ers

14

.1-4

00

RVO

14

.1-4

00

OP

N

14

.1-4

00

RVR

D

13

13

.2-4

00

TN

Cel

ls w

ith

volt

age

tran

sfor

mer

s

13

.1-4

00

TN

12

12

.2-6

00

TN

Mai

n ci

rcui

t di-

agra

m

Dia

gram

nu

mb

er

Indi

catio

n of

m

ain

circ

uit d

i-ag

ram

impl

e-m

enta

tion

KS

O c

ell n

ame

(acc

ordi

ng to

m

ain

com

po-

nent

par

ts)

Page 7: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

6

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l cir

cuit

diag

ram

s

28

28

A

Auxi

liary

cel

l

27

27

NO

-60

02

7E-

60

02

7E

V-6

00

Cel

l for

inst

alla

tion

of

hig

h vo

ltag

e sw

itch

(res

erve

)

26

26

-60

02

6-1

00

0

Cel

l wit

h tie

br

eake

rs

25

25

.2-6

00

TN2

5.2

-10

00

TN2

5.2

-16

00

TN

Cel

ls w

ith

volt

age

tran

sfor

mer

s

25

.1-6

00

TN2

5.1

-10

00

TN2

5.1

-16

00

TN

24

24

-60

02

4-1

00

02

4-1

60

0

Cel

ls w

ith

tie

bre

aker

of

sect

iona

l sw

itch

23

23

-60

02

3-1

00

02

3-1

60

0

Cel

ls w

ith

cabl

e as

sem

blie

s

22

22

-60

02

2-1

00

02

2-1

60

0

20

20

-40

0TN

Cel

l wit

h vo

ltag

e tr

ansf

orm

er

Mai

n ci

rcui

t di

agra

m

Dia

gram

nu

mb

er

Indi

catio

n of

m

ain

circ

uit

diag

ram

im-

plem

enta

tion

KS

O c

ell

nam

e (a

cco

rdin

g to

m

ain

com

po-

nent

par

ts)

Page 8: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

7

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l cir

cuit

diag

ram

s

29

29

.2-6

00

29

.2-1

00

0

Cel

l wit

h C

able

gla

nd

29

.1-6

00

29

.1-1

00

0

Mai

n ci

rcui

t dia

gram

Dia

gram

num

ber

Indi

catio

n of

mai

n

circ

uit d

iagr

am

impl

emen

tatio

n

KS

O c

ell n

ame

(acc

ordi

ng to

mai

n

com

pone

nt p

arts

)

Page 9: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

8

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l blo

ck c

ircu

it di

agra

ms

16

16

-40

0TS

N2

51

6-4

00

-TS

N4

0

Bus

inpu

t

18

18

-60

0TN

18

-10

00

TN1

8-1

60

0TN

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

19

19

-60

0TN

19

-10

00

TN1

9-1

60

0TN

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

22

22

-60

02

2-1

00

02

2-1

60

0

Inpu

t or b

ran

ch li

ne

6

6P

O-6

00

6E-

60

06

PO

-10

00

6E-

10

00

6E

V-6

00

6E

V-1

00

06

EV-

16

00

22

22

-60

02

2-1

00

02

2-1

60

0

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

Mai

n ci

rcui

t di

agra

m

Dia

gram

num

ber

Indi

catio

n of

mai

n

circ

uit d

iagr

am

impl

emen

tatio

n

Fun

ctio

n

Page 10: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

9

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l blo

ck c

ircu

it di

agra

ms

16

16

-40

0TS

N2

51

6-4

00

TSN

40

Cab

le g

lan

d

28

28

A

23

23

-60

02

3-1

00

02

3-1

60

0

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

16

16

-40

0TS

N2

51

6-4

00

TSN

40

Pow

er tr

ansf

orm

er le

ad28

28

A

18

18

-60

0TN

18

-10

00

TN1

8-1

60

0TN

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

Mai

n ci

rcui

t di

agra

m

Dia

gram

num

ber

Indi

catio

n of

mai

n

circ

uit d

iagr

am

impl

emen

tatio

n

Fun

ctio

n

Page 11: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

10

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l blo

ck c

ircu

it di

agra

ms

24

24

-60

02

4-1

00

02

4-1

60

0

Sec

tiona

l sw

itch

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

25

25

-60

0TN

25

-10

00

TN2

5-1

60

0TN

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

16

16

-40

0TS

N2

51

6-4

00

TSN

40

Cab

le g

lan

d

28

28

A

23

23

-60

02

3-1

00

02

3-1

60

0

6

6P

O-6

00

6E-

60

06

PO

-10

00

6E-

10

00

6E

V-6

00

6E

V-1

00

06

EV-

16

00

Mai

n ci

rcui

t di

agra

m

Dia

gram

num

ber

Indi

catio

n of

mai

n

circ

uit d

iagr

am

impl

emen

tatio

n

Fun

ctio

n

Page 12: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

11

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l blo

ck c

ircu

it di

agra

ms

16

16

-40

0TS

N2

51

6-4

00

TSN

40

Cab

le g

lan

d

23

23

-60

02

3-1

00

02

3-1

60

0

6

6P

O-6

00

5E-

60

06

PO

-10

00

6E-

10

00

6E

V-6

00

6E

V-1

00

06

EV-

16

00

16

16

-40

0TS

N2

51

6-4

00

TSN

40

23

23

-60

02

3-1

00

02

3-1

60

0

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

20

20

-40

0TN

23

23

-60

02

3-1

00

02

3-1

60

0

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

05

EV-

16

00

Mai

n ci

rcui

t di

agra

m

Dia

gram

nu

mb

er

Indi

catio

n of

m

ain

circ

uit d

i-ag

ram

impl

e-m

enta

tion

Fun

ctio

n

Page 13: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

12

ww

w.u

ztt.

ru

Mai

n K

SO

cel

l blo

ck c

ircu

it di

agra

ms

16

16

-40

0TS

N2

51

6-4

00

TSN

40

Cab

le g

lan

d

29

.2

29

.2-6

00

29

.2-1

00

0

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

0

29

.1

29

.1-6

00

29

.1-1

00

0

Cab

le g

lan

d

5

5P

O-6

00

5E-

60

05

PO

-10

00

5E-

10

00

5E

V-6

00

5E

V-1

00

0

15

15

-40

0TS

N2

51

5-4

00

TSN

40

Auxi

liary

tran

sfor

mer

28

28

A

Mai

n

circ

uit

diag

ram

Dia

gram

num

ber

Indi

catio

n of

m

ain

circ

uit d

i-ag

ram

impl

e-m

enta

tion

Fun

ctio

n

Page 14: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

13

ww

w.u

ztt.

ru

Table 2. KSO Cells Main Technical Data

Main technical parameters Parameter value

Nominal voltage (linear), kV 6; 10

Maximum operating voltage, kV 7,2; 12

Nominal current of KSO cell main circuits, A 400; 630; 1000; 1600

Nominal current of KSO cell main circuitsWith load-break switch, A

400; 630

Nominal bus bar current, A 630; 1000; 1600

Nominal ammeter transformer current, A50; 75; 100; 150; 200; 300; 400; 600; 800; 1000; 1500

Nominal bus bridge current, A 630; 1000

Nominal high-voltage switch breaking current, kA 20

Nominal load-break switch breaking current, with cosφ≥0,7, A 400; 630

Nominal power fuse strip current, A2; 3; 5; 8; 10; 16; 20;

31,5-100; 160 (for 6 kV)

Nominal short-time electrodynamic current of main KSO cell circuits (amplitude), kA

51*

Short-time thermal current, kA 20

Short-time thermal current flow time, s:For 400 and 630 A cellsFor 1000 and 1600 A cellsFor cells with load-break switchesFor earthing blades

2311

Nominal auxiliary circuit voltage, V:Protection, control and signal DC and AC circuitsVoltage transformer circuitsLighting circuitsInside the KSO cellOutside the KSO cellAuxiliary transformer cellsVacuum circuit breaker enabling/disabling electric magnets (DC)

220100

42 (36)220

220; 380220

Dimensions, mm

WidthDepth (at the base)Height (with bus bars)Frame height

StandardReduced

dimensions**

1000110027802300

Weight of cells, kg:With high-voltage switchesWith voltage transformersOther

630-750350-575315-800

*On clients’ request transformers with low ratio are used in KSO cells. Their electrodynamic and thermic capability is less than that of the cells.** On request the KSO cells can be implemented with reduced dimensions.

Page 15: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

14

ww

w.u

ztt.

ru

Table 3. KSO Cell Classification

Classification features KSO cell implementation

Type of KSO cells depending on equipment installed

KSO cells with high-voltage switches: VPMP-M-10 with PPO-10 drive;

VPM-M-10 with PE-11 drive; VVTE-M-10; KSO cells withVN-10 load-breaking switches with SF drive;

KSO cells with power fuses;

KSO cells with voltage transformers;

KSO cells with charge neutralizers and excess-voltage suppressors (OPN-RS);

KSO cells with25 kV and 40 kV auxiliary transformers;

KSO cells with cable assemblies;

KSO cells with disconnecting devices;

KSO cells with auxiliary equipment and rectified operating power equipment

Insulation level according to GOST 1516.1

KSO cells with normal insulation

Bus bar insulation KSO cells with non-isolated buses

Bus bar system KSO cells with single bus bar system.

KSO cell bus bars for nominal currents ranging from 400 to 1000 A

Are implemented with buses produced from AD31T aluminum alloy, for 1600 A – are implemented with copper buses

Means of phase separation KSO cells with non-separated phases

High-voltage lead construction KSO cells with cable connection;

KSO cells with bus connection

Installation type KSO cells for indoor installation in electrical rooms

Protection degree according to GOST 14254

IP20 – for front side of the enclosing (on height up to 2100 mm from cell base) and IP10 for other KSO cell parts

Maintenance conditions KSO cells of one-sided maintenance

Main built-in equipment used for primary connections:

• VPMP-M-10 type high-voltage switches with PE-11 drive:• VVTE-M-10 type vacuum circuit breakers with built-in electromagnetic drive;• RVZ-10 disconnectors with earthing blades;• RV-10 disconnectors;• RVF-10 and RVFZ-10 disconnectors;• TOL-10 current transformers;• TZLM current transformers;• NAMI type voltage transformers (or 3xZNOL – on request);• NOM (ZNOL – on request);• TM-25 or TSKS-40 type transformers;• RVO and RVND type charge neutralizers• OPN-RS and OPN-KS type excess-voltage suppressor• KEK type static condensers;• PKT and PKN type fuses.

Page 16: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

15

ww

w.u

ztt.

ru

DesignKSO-292 series cells are basically a complete analog of KSO-285 cells both in power diagrams and in secondary diagrams. In comparison with KSO-286 cells, the KSO-292 cells have the cur-rent transformer module (TOL-10) moved from the back wall to the front wall. Other external and connecting dimensions are similar.

KSO cells are implemented as welded metal structures made of folded steel sections. Inside the cell the main function equipment is placed. Switch and disconnector drives and auxiliary equipment are located on the front side.

Access inside the cell is provided via two doors: upper door – to power-switch zone, voltage transformer and fuse, lower door – to cable connections zone, power transformer and charge neutralizers. The lower door has an inspection window for viewing the inner part without re-moval of voltage. The upper door serves as a panel, on which the auxiliary circuit equipment is mounted. The cables are protected against high voltage by a removable steel sheet with an in-spection window.

On the front side of the center cell section the connecting terminal panel is located, serving as a channel for backbone buses of operating power circuits of switching-on electromagnets, con-trol and signal circuits, for performing inter-cell secondary connections when mounting KSO cells.

Markings of circuits, connected to the terminals, are given in electric essentials, supplied by the company on client’s request.

KSO cell design allows assembling of all the cells into a switchgear row and connection of main circuits with bus bars. Connection with linear buses is possible between cells, compris-ing blocks. According to main block circuit diagram, connection with linear buses is performed for neighboring cells within a single row.

If two-row cell positioning is used, bus bridges with or without disconnectors are used for con-necting main circuits with bus bars. Bus bars, bus and sectional KSO cell disconnectors are equipped with enclosing grilles on the front side.

The following blockings are present in the KSO cells:

• Blocking, preventing switching on and switching off of linear and bus disconnectors with energized high-voltage switch or load-break switch;

• Blocking, preventing enabling of the earthing blades with enabled operating disconnec-tor blades ;

• Blocking, preventing enabling of the disconnectors with enabled earthing blades.

In technically justified cases, on request, electromagnetic blocking devices are installed in the KSO cells on the earthing blade drives. Electromagnetic locks are installed on the earthing blade drives of bus bars regardless of request.

Bulb socket for interior lighting is installed inside each cell. Drive-earthing blade handles are colored red. Earthing blades, earthing blade drives and earthing buses are colored black. Drives of main and earthingdisconnectors are equipped with devices, allowing them to be locked in enabled or disabled position by padlocks.

KSO cell body allows welding it directly to earthed metal structures. Earthing clamp for con-nection of elements, needing temporary earthing, to the cell body is located on the front side of the cell.

Page 17: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

16

ww

w.u

ztt.

ru

Table 4. Bus Bar Bridge Types

Engineering document identification

Nominal current, A

L, mm* L, mm** Notes

VLIE. 685515.001

630

3340 2300

Without disconnector

-01 3840 2800

-02 4390 3300

-03 4840 3800

-04 5240 4200

-05

1000

3340 2300

-06 3840 2800

-07 4300 3300

-08 4840 3800

-09 5240 4200

VLIE.685515.002

630

3340 2300

With two disconnectors

-01 3840 2800

-02 4390 3300

-03 4840 3800

-04 5240 4200

-05

1000

3340 2800

-06 3840 2800

-07 4390 3300

-08 4840 3800

-09 5240 4200

*bus bridge length**distance between front sides of cells

Scope of Supply

The following is included into scope of supply:

• KSO cells with equipment and instruments of main and auxiliary circuits according to the order (cells are supplied per item or in blocks, with block containing up to two cells);

• Bus bridges (if mentioned in the order);• Spare parts and accessories for parts according to SPTA set lists for these items;• Exploitative documents.

Exploitative documents include:

• Technical description and operating instructions for KSO cells;• Technical descriptions and operating instructions, passports for main components;• Order specification or questionnaire;• Auxiliary circuit diagrams (foe cells) according to order;• KSO cell kit passport

KSO cells for internal Russian shipping and international shipping comply with TU 3414-001096418566-2007 and are designed according to main circuit diagrams (Table 1), observ-ing the safety procedures – GOST 12.2.007.3-75.

General warranty period of KSO cells (exploitation and storage) is 1 year.

Page 18: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

17

ww

w.u

ztt.

ru

Tab

le 5

. Au

xilia

ry C

ircu

it D

iag

ram

s

6-1

0 k

V d

isco

nn

ect

or;

se

ctio

nal

dis

con

ne

cto

r; b

us

inp

ut,

ch

arge

neu

tral

izer

an

d s

tati

c co

nd

ense

rs;

cab

le a

ssem

bly

; vo

lta

ge t

ran

sfo

rmer

9, 1

4, 1

8*,

19

*, 2

0*,

2

2, 2

3, 2

4, 2

6, 2

7, 2

9

06

0

On

re

qu

est

On

re

qu

est

On

re

qu

est

reg

ard

ing

mai

n c

ircu

its

9, 1

4, 1

8*,

19

*, 2

0*,

2

2, 2

3, 2

4, 2

6, 2

7, 2

9

05

9

9, 1

4, 1

8*,

19

*, 2

0*,

2

2, 2

3, 2

4, 2

6, 2

7, 2

9

05

8

9, 1

4, 1

8*,

19

*, 2

0*,

2

2, 2

3, 2

4, 2

6, 2

7, 2

9

05

6

9, 1

4, 1

8*,

19

*, 2

0*,

2

2, 2

3, 2

4, 2

6, 2

7, 2

9

05

5

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

am

Nu

mb

ers

of V

LIE

. 30

179

1…

E3

ser

ies

auxi

liary

cir

cuit

dia

gram

s

NO

M, Z

NO

L vo

lta

ge t

ran

sfo

rmer

Nu

mb

er o

f zer

o-s

eq

uen

ce c

urr

ent t

ran

sfo

rmer

s

Re

ctif

ied

DC

AC

Volt

age

cir

cuit

s co

ntr

ol r

elay

Mai

ns

bu

ses

pow

er

Mai

ns

bu

ses

segm

enta

tio

n

Cen

tral

sig

nal

iza

tio

n

Au

tom

ati

c fr

eq

uen

cy lo

ad

sh

ed

din

g, fr

e-

qu

ency

act

ua

ted

au

tom

ati

c re

clo

sin

g

Fre

qu

ency

act

ua

ted

au

tom

ati

c lo

ad

tr

ansf

er

Co

nd

ense

r b

lock

s fo

r re

ctif

ied

cu

rren

t

Blo

ck-l

ock

(Y2

) an

d b

lock

-co

nta

cts

(SQ

2)

of t

he

ear

thin

g d

isco

nn

ect

or

Blo

ck-l

ock

(Y1

) an

d b

lock

-co

nta

cts

(SQ

1)

of t

he

ear

thin

g d

isco

nn

ect

or

Op

era

tin

g p

ower

Op

era

tin

g b

lock

ing

*blo

ck-lo

ck o

n th

e ea

rthi

ng d

isco

nnec

tor o

f bus

bar

s is

alw

ays

inst

alle

d

Iden

tific

atio

n m

arks

:

Pre

sen

ce o

f equ

ipm

ent i

s de

term

ined

by

type

Equ

ipm

ent i

n al

l dia

gram

typ

es

Page 19: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

18

ww

w.u

ztt.

ru

Sec

tion

al s

wit

ch 6

-10

kV 5

A, C

DC

rec

tifi

ed

On

req

ue

st r

egar

din

g m

ain

cir

cuit

dia

gram

s5

00

8

00

8*

5

00

7

00

7*

Inp

ut 6

, 10

kV,

re

serv

e 5, 6

, 8

00

6

00

6*

A, C

, B –

on

req

ue

st

5, 6

, 8

00

5

00

5*

Inp

ut 6

, 10

kV

5, 6

, 8

00

4

00

4*

5, 6

, 8

00

3

00

3*

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

am

Nu

mb

ers

of V

LIE

. 30

179

1…

E3

ser

ies

auxi

liary

cir

cuit

dia

gram

s

Nu

mb

ers

of V

LIE

. 30

179

1…

E3

.1*

seri

es

auxi

liary

cir

cuit

dia

gram

s

Ph

ase

s, in

wh

ich

cu

rren

t tra

nsf

orm

ers

are

inst

alle

d

Op

erat

ing

pow

er

Act

ive

and

rea

ctiv

e e

ner

gy m

eter

s

Am

per

e m

eter

Con

trol

key

Latc

hin

g re

lay

of e

nab

led

po

siti

on o

f th

e sw

itch

Nu

mb

er o

f zer

o-s

equ

ence

cu

rren

t tra

nsf

orm

ers

Ma

xim

um

cu

rren

t pro

tect

ion

in 2

-ph

ase

2-r

elay

imp

lem

enta

tion

Cap

abili

ty o

f con

nec

tion

to

TA1-

A,B

,C c

urr

ent t

ran

sfor

mer

s

Re

-syn

chro

niz

atio

n b

us

form

atio

n r

elay

±S

hR

S

Au

tom

atic

tra

nsf

er s

wit

ch in

itia

ted

acc

ord

ing

to v

olta

ge

Volt

age

and

freq

uen

cy a

ctu

ated

au

tom

atic

loa

d t

ran

sfer

Rel

ay o

f sin

gle

auto

mat

ic lo

ad

tra

nsf

er a

ctu

atio

n

Pro

hib

itio

n r

elay

of a

uto

mat

ic lo

ad

tra

nsf

er

Pro

tect

ion

aga

inst

gro

un

d s

hor

t cir

cuit

wit

h R

T3-5

1 o

r R

T-4

0/0

,2 r

elay

Freq

uen

cy a

nd

vol

tage

con

trol

on

re

serv

e in

pu

t

Con

trol

of r

esi

du

al v

olta

ge in

th

e se

ctio

n

Op

erat

ing

blo

ck –

lock

-blo

ck t

he

eart

hin

g d

isco

nn

ecto

r (Y

2);

lock

-blo

ck (

Y1) a

nd

blo

ck-c

on-

tact

s (S

Q1

) of t

he

eart

hin

g d

isco

nn

ecto

r

Inst

rum

ents

Ch

ara

cter

isti

c of

re

lay

pro

tect

ion

an

d a

uto

mat

ion

d

evic

es

Page 20: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

19

ww

w.u

ztt.

ru

Se

ctio

nal

sw

itch

6-1

0 k

V

1,2

,5,6

,8

01

6

01

6*

A, C

, B –

on

re

qu

est

On

requ

est

Rec

tifie

d D

C

On

re

qu

est

reg

ard

ing

mai

n c

ircu

it d

iagr

ams

1,2

,5,6

,8

01

5

01

5*

1,2

,5,6

,8

01

4

01

4*

Auto

mat

ic re

clos

ing

1,2

,5,6

,8

01

3

01

3*

6-1

0 k

V lin

e

1,2

,5,6

,8

01

2

01

2*

1,2

,5,6

,8

01

1

01

1*

1,2

,5,6

,8

01

0

01

0*

Auto

mat

ic re

clos

ing

1,2

,5,6

,8

00

9

00

9*

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

am

Num

ber

s of

VLI

E. 3

017

91

…E

3 s

erie

s au

xilia

ry c

ircu

it di

agra

ms

Num

ber

s of

VLI

E. 3

017

91

…E

3.1

* se

ries

au

xilia

ry c

ircu

it di

agra

ms

Pha

ses

on w

hich

cur

rent

tran

sfor

mer

s ar

e in

stal

led

Num

ber

of z

ero

-seq

uen

ce c

urre

nt tr

ansf

orm

ers

Ope

ratin

g po

wer

Act

ive

and

re

act

ive

en

erg

y m

eter

s

Am

per

e m

eter

Co

ntr

ol k

ey

Two

-pos

itio

n re

lay

Plu

g b

eads

2-r

elay

impl

emen

tatio

n

3-r

elay

impl

emen

tatio

n

Cur

ren

t cu

toff

in 2

-ph

ase

and

2-r

elay

impl

emen

tatio

n (w

ith

RT-

40

rel

ay)

Cur

rent

cu

toff

in s

ingl

e-re

lay

impl

emen

tatio

n (w

ith

RT-

83

or R

T-4

0 re

lay)

Pro

tect

ion

agai

nst g

roun

d sh

ort c

ircu

it w

ith

RT3

-51

or R

T-4

0/0

,2 re

lay

Ove

rloa

d pr

otec

tion

wit

h sh

ut-

off a

nd

alar

m

Ove

rloa

d pr

otec

tion

wit

h al

arm

Gas

pro

tect

ion

– w

ith

alar

m a

nd

shu

t-of

f

Au

tom

ati

c fr

eq

uen

cy lo

ad

sh

ed

din

g sh

ut-

off r

elay

Volt

age

dro

p s

hu

t-of

f rel

ay

RP

-23

Cha

ract

eris

tic o

f au

tom

atio

n de

vice

s

Ope

ratin

g bl

ock

– lo

ck-b

lock

the

eart

hing

dis

conn

ecto

r (Y2

); lo

ck-b

lock

(Y1

) an

d bl

ock-

cont

acts

(S

Q1

) of t

he e

arth

ing

disc

onne

ctor

Max

imum

cur

rent

pro

tect

ion

in

2-p

hase

Au

xilia

ry o

utp

ut r

elay

of p

rote

ctio

n

act

ion

Emer

gen

cy s

hut-

off a

larm

by

mea

ns o

f

Mea

suri

ng

inst

rum

ents

Ch

ara

cter

isti

c of

rel

ay

pro

tect

ion

an

d a

uto

-m

ati

on

dev

ice

s

Page 21: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

20

ww

w.u

ztt.

ru

Lin

e to

th

e co

nve

rsio

n

un

it 1,2

,5,

6,8

02

9

02

9*

A, C

, B –

on

re

qu

est

On

requ

est

Rec

tifie

d D

C

On

re

qu

est

reg

ard

ing

mai

n c

ircu

it d

iagr

ams

1,2

,5,

6,8

02

8

02

8*

Sta

tic

con

den

ser

ba

tter

y

1,2

,5,

6,8

02

7

02

7*

RA

1, R

A2

, RA

3 -

cc

ord

ing

to im

ple

me

nta

tio

ns

1,2

,5,

6,8

02

6

02

6**

1,2

,5,

6,8

02

5

02

5*

1,2

,5,

6,8

02

4

02

4*

“Tra

nsfo

rmer

” un

it –

as

ynch

rono

us

mot

or 1,2

,5,

6,8

02

3

02

3*

1,2

,5,

6,8

02

2

02

2*

Syn

chro

-n

ous

mot

or

1,2

,5,6

,8

02

1

02

1*

Asy

nch

ron

ous

mot

or

1,2

,5,

6,8

03

0

03

0*

1,2

,5,

6,8

01

9

01

9*

1,2

,5,

6,8

01

8

01

8*

1,2

,5,

6,8

01

7

01

7*

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

ams

Num

ber

s of

VLI

E. 3

017

91

…E

3 s

erie

s au

xilia

ry c

ircu

it di

agra

ms

Num

ber

s of

VLI

E. 3

017

91

…E

3.1

* se

ries

au

xilia

ry c

ircu

it di

agra

ms

Pha

ses

on w

hich

cur

rent

tran

sfor

mer

s ar

e in

stal

led

Num

ber

of z

ero

-seq

uen

ce c

urre

nt tr

ansf

orm

ers

Ope

ratin

g po

wer

Act

ive

ener

gy

met

er

Rea

ctiv

e en

erg

y m

eter

Am

per

e m

eter

Two

-pos

itio

n re

lay

Plu

g b

eads

2-r

elay

impl

emen

tatio

n

In 2

-ph

ase

, 2-r

elay

imp

lem

enta

tio

n (R

T-4

0)

Ma

xim

um

cu

rren

t pro

tect

ion

Pro

tect

ion

agai

nst g

roun

d sh

ort c

ircu

it w

ith

RT3

-51

or R

T-4

0/0

,2 re

lay

Ove

rloa

d pr

otec

tion

wit

h R

T-4

0 re

lay

shu

t-of

f

Pro

tect

ion

agai

nst o

verl

oad

and

pole

slip

ping

Ove

rlo

ad

pro

tect

ion

wit

h s

hu

t-of

f an

d a

larm

Ga

s p

rote

ctio

n –

wit

h a

larm

an

d s

hu

t-of

f

Au

xilia

ry o

utp

ut r

elay

of p

rote

ctio

n a

ctio

n (R

P-2

3B

RU

-1)

Au

tom

ati

c fr

eq

uen

cy lo

ad

sh

ed

din

g sh

ut-

off r

elay

1 S

hM

N (2

Sh

MN

) bu

ses

± S

hR

S b

use

s

Volt

age

incr

ea

se p

rote

ctio

n

Co

nd

ense

r u

nit

Op

era

tin

g b

lock

– lo

ck-b

lock

the

eart

hin

g d

isco

nn

ect

or (Y

2);

lock

-blo

ck (Y

1) a

nd

blo

ck-c

onta

cts

(SQ

1) o

f th

e e

arth

ing

dis

con

ne

cto

r

Emer

gen

cy s

hut-

off a

larm

by

mea

ns o

f

Cu

rren

t cu

toff

Volt

age

dro

p

shu

t-of

f rel

ay

Mea

suri

ng

inst

rum

ents

Ch

ara

cter

isti

c of

rel

ay

pro

tect

ion

an

d a

uto

-m

ati

on

dev

ice

s

Page 22: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

21

ww

w.u

ztt.

ru

Volt

age

tra

nsf

orm

er

12

,13

,25

03

8

Y2 –

for

all i

mp

lem

enta

tio

ns,

SQ

2 –

on

re

qu

est

Y1; Y

3 –

on

re

qu

est

reg

ard

ing

mai

n c

ircu

it d

iagr

ams

12

,13

,25

03

7

12

,13

,25

03

6

12

,13

,25

03

5

12

,13

,25

03

4

12

,13

,25

03

3

12

,13

,25

03

2

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

am

Nu

mb

ers

of V

LIE

. 30

179

1…

E3

ser

ies

auxi

liary

cir

cuit

dia

gram

s

NA

MI 3

x3N

OL

(on

re

qu

est

)

NO

M; 3

NO

L (o

n r

eq

ue

st)

DC

AC

Volt

age

met

er

“Gro

un

d in

6-1

0 k

V c

ircu

it”

alar

m

Volt

age

cir

cuit

s co

ntr

ol

Insu

lati

on

co

ntr

ol

Volt

age

ad

just

men

t cen

ter

Au

tom

ati

c lo

ad

tra

nsf

er b

lock

ing

cen

ter

On

AC

op

era

tin

g p

ower

On

DC

op

era

tin

g p

ower

On

op

erat

ing

DC

pow

er o

f fre

quen

cy a

ctu

ated

au

tom

atic

rec

losi

ng

– w

ith

tim

e d

elay

Wit

h p

ower

fro

m lo

w-v

olt

age

eq

uip

men

t SN

ca

bin

et

Cen

tral

ala

rm (e

mer

gen

cy a

nd

war

nin

g in

dic

ati

on)

Blo

ck-l

ock

(Y2

) an

d b

lock

-co

nta

cts

(SQ

2) o

f th

e ea

rth

ing

dis

con

ne

cto

r of

bu

s b

ars

Blo

ck-l

ock

(Y1

;Y3

) of t

he

eart

hin

g d

isco

nn

ect

or

Au

tom

ati

c fr

eq

uen

cy

loa

d s

he

dd

ing,

fre

qu

ency

a

ctu

ate

d a

uto

ma

tic

recl

osi

ng

Min

imal

vo

lta

ge p

rote

ctio

n

Tran

sfo

rmer

typ

e

Op

era

tin

g p

ower

Mea

suri

ng

inst

rum

ents

Ch

ara

cter

isti

c of

re

lay

pro

tect

ion

an

d

auto

ma

tio

n d

evic

es

Op

era

tin

g b

lock

Page 23: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

22

ww

w.u

ztt.

ru

6-1

0 k

V li

ne,

Lin

e to

tra

nsf

orm

er, t

ran

sfo

rmer

1, 2

, 5, 6

, 8

04

5

A, C

, B –

on

re

qu

est

On

re

qu

est

AC

On

re

qu

est

reg

ard

ing

mai

n c

ircu

it d

iagr

ams

1, 2

, 5, 6

, 8

04

4

1, 2

, 5, 6

, 8

04

3

1, 2

, 5, 6

, 8

04

2

Inp

ut –

se

ctio

nal

sw

itch

5, 6

, 8

04

0

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

am

Nu

mb

ers

of V

LIE

. 30

179

1…

E3

ser

ies

auxi

liary

cir

cuit

dia

gram

s

Ph

ase

s o

n w

hic

h c

urr

ent t

ran

sfo

rmer

s ar

e in

stal

led

Nu

mb

er o

f zer

o-s

eq

uen

ce c

urr

ent t

ran

sfo

rmer

s

Op

era

tin

g p

ower

Act

ive

ener

gy

met

er

Rea

ctiv

e en

erg

y m

eter

Am

per

e m

eter

“Gro

un

d in

6-1

0 k

V c

ircu

it”

alar

m

On

dir

ect

-act

ion

rel

ay

Wit

h R

T-4

0, R

P-3

61

de

-sh

un

tin

g

Wit

h R

T-8

5 d

e-s

hu

nti

ng

Wit

h R

T-8

5 d

e-s

hu

nti

ng

Wit

h R

T-4

0, R

P-3

61

de

-sh

un

tin

g

On

dir

ect

-act

ion

rel

ay

Ove

rlo

ad

pro

tect

ion

Pro

tect

ion

agai

nst

gro

und

shor

t cir

cuit

wit

h R

T3-5

1 o

r RT-

40/

0,2

rel

ay

Ga

s p

rote

ctio

n –

wit

h a

larm

an

d s

hu

t-of

f

Tech

no

logi

cal f

ault

sh

ut-

off r

elay

Au

tom

ati

c fr

eq

uen

cy lo

ad

sh

ed

din

g sh

ut-

off r

elay

Au

tom

ati

c lo

ad

tra

nsf

er

Au

tom

ati

c re

clo

sin

g

Op

era

tin

g b

lock

– lo

ck-b

lock

th

e e

arth

ing

dis

con

ne

cto

r (Y

2);

lock

-blo

ck (

Y1) a

nd

blo

ck-c

on

-ta

cts

(SQ

1) o

f th

e ea

rth

ing

dis

con

ne

cto

r

Cu

rren

t cu

toff

Ma

xim

um c

urre

nt p

ro-

tect

ion

Mea

suri

ng

inst

rum

ents

Ch

ara

cter

isti

c of

re

lay

pro

tect

ion

an

d

auto

ma

tio

n d

evic

es

Page 24: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

23

ww

w.u

ztt.

ru

Lin

e to

co

nve

rtin

g u

nit

1, 2

, 5, 6

, 8

05

0

А, С

On

re

qu

est

AC

AC

On

re

qu

est

reg

ard

ing

mai

n c

ircu

it d

iagr

ams

Lin

e to

sta

tic

con

-d

ense

r b

att

ery

1, 2

, 5, 6

, 8

04

9

RA

1, R

A2

, RA

3 -

acco

rd-

ing

to im

ple

men

tati

ons

Asy

nch

ron

ous

mot

or

tran

sfo

rmer

un

it –

asy

nch

ron

ous

mot

or

1, 2

, 5, 6

, 8

04

8

DC

1, 2

, 5, 6

, 8

04

6

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

am

Nu

mb

ers

of V

LIE

. 30

179

1…

E3

ser

ies

auxi

liary

cir

cuit

dia

gram

s

Ph

ase

s o

n w

hic

h c

urr

ent t

ran

sfo

rmer

s ar

e in

stal

led

Nu

mb

er o

f zer

o-s

eq

uen

ce c

urr

ent t

ran

sfo

rmer

s

Cir

cuit

s of

ind

epen

den

t pow

er s

up

ply

ele

ctro

ma

gnet

Act

ive

ener

gy

met

er

Rea

ctiv

e en

erg

y m

eter

Am

per

e m

eter

On

dir

ect

-act

ion

rel

ay

Wit

h R

T-4

0, R

P-3

41

de

-sh

un

tin

g

Ma

xim

um

cu

rren

t pro

tect

ion

on

dir

ect

-act

ion

rel

ay

Ove

rlo

ad

pro

tect

ion

wit

h s

hu

t-of

f an

d a

larm

Pro

tect

ion

aga

inst

gro

un

d s

ho

rt c

ircu

it w

ith

RT3

-51

or

RT-

40/

0,2

rel

ay

Pro

tect

ion

aga

inst

vo

lta

ge in

cre

ase

Ga

s p

rote

ctio

n –

wit

h a

larm

an

d s

hu

t-of

f

Tech

no

logi

cal f

ault

sh

ut-

off r

elay

For

shu

t-of

f in

ca

se o

f vo

lta

ge d

rop

Au

tom

ati

c fr

eq

uen

cy lo

ad

sh

ed

din

g sh

ut-

off r

elay

Op

era

tin

g b

lock

– lo

ck-b

lock

th

e ea

rth

ing

dis

con

ne

cto

r (Y

2);

lock

-blo

ck (

Y1)

and

blo

ck-c

on

tact

s (S

Q1

) of t

he

ear

thin

g d

isco

nn

ect

or

Cu

rren

t cu

toff

Op

era

tin

g p

ower

Mea

suri

ng

inst

rum

ents

Ch

ara

cter

isti

c of

re

lay

pro

tect

ion

an

d

auto

ma

tio

n d

evic

es

Page 25: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

24

ww

w.u

ztt.

ru

Low

-vo

lta

ge e

qu

ipm

ent c

ell

28

05

4

Au

xilia

ry t

ran

sfo

rmer

15

, 16

06

1

On

re

qu

est

KS

O c

ell f

un

ctio

n

Nu

mb

er o

f mai

n c

ircu

it d

iagr

am

Nu

mb

ers

of V

LIE

. 30

179

1…

E3

ser

ies

auxi

liary

cir

cuit

dia

gram

s

Au

xilia

ry t

ran

sfo

rmer

vo

lta

ge –

0,4

kV

or

0,2

3 k

V

Pre

sen

ce o

f cu

rren

t tra

nsf

orm

ers Vo

lta

ge m

eter

Act

ive

ener

gy

met

er

Volt

age

cir

cuit

sh

ut-

off r

elay

0,4

kV

an

d 0

,23

kV

au

tom

ati

c lo

ad

tra

nsf

er c

ircu

its

Op

era

tin

g b

us

circ

uit

pow

er

Pow

er

for

op

era

tin

g b

lock

ing

circ

uit

s a

nd

min

ima

l vo

lta

ge p

rote

ctio

n

circ

uit

s

Au

tom

ati

c sh

ut-

off f

or

pow

er b

lock

s of

se

ctio

n v

olt

age

(BN

PS

)

Pow

er b

lock

s an

d c

on

den

ser

blo

cks

Gro

un

d s

ho

rt c

ircu

it a

larm

ing

dev

ice

(US

Z-3

m)

Ca

pab

ility

of

con

ne

ctio

n t

o gr

oup

pro

tect

ion

aga

inst

gro

un

d s

ho

rt c

ir-cu

it fo

r 1

0 a

nd

20

ou

tgoi

ng

circ

uit

s

Op

era

tin

g b

lock

ing

– b

lock

-lo

ck (

Y1);

for

ma

in c

ircu

it d

iagr

am

of

15

ea

rth

ing

dis

con

ne

cto

r b

lad

es;

fo

r m

ain

cir

cuit

dia

gram

of 1

6 e

arth

ing

dis

con

ne

cto

r b

lad

es

Mea

suri

ng

inst

rum

ents

Ch

ara

cter

isti

c of

rel

ay

pro

tect

ion

an

d a

uto

ma

tio

n

dev

ice

s

Page 26: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

25

ww

w.u

ztt.

ru

Cell dislocation

plan

Customer:

Seal

« » 2012

Supplier: UZTT, LLC. Director of UZTT, LLCA. S. Makushev

Seal« » 2012 Executive

Questionnaire

Interrogation data Cell type

Bus barsVoltage, kVMaterial and section

Primary connection diagram

Cell function

Cell dimensionsStandardReduced

Nominal cell current, ANumber of main circuit diagramNumber of secondary circuit diagram

Disconnector typeBusLinear

Disconnector drive controlLocalRemote

Switch typeVacuumOil

Switch drive typeElectromagneticSpring-motor

Vacuum switch control unit typeOperating power (type, voltage)

Current transformersTypeTransformation ratioPrecision class

Zero sequence current transformerAuxiliary transformer typeVoltage transformer type

Metering deviceTypePrecision class

Fuse typeExcess-voltage suppressor (OPN)

Rel

ay p

rote

ctio

n t

ype

s, t

hei

r a

ctio

n (d

isco

nn

ecti

on o

r si

gnal

), re

lay

typ

e

Voltage protection

From open-phase operating conditions

Of minimal voltage

Current protections

Overcurrent protection with time delayCurrent cutoffOverloadAgainst ground short-circuit

Other

Operating blockings setBlocking of disconnector drive with mechanical locksPresence of anti-condensate heatingNumber of cells ordered

Page 27: Ural Company for Transformer Technologies, LLCuztt.ru/eng/files/core/1525_file.pdf · to GOST 15150-69 and GOST 15543-70. KSO-292 Series Factory-Assembled Switchgear Cells оf One-Sided

KSO-292 Series Factory-Assembled

Switchgear Cells оf One-Sided Maintenance

26

ww

w.u

ztt.

ru

Certificate No. ROSS RU.AI50.V05884

Cell dislocation

plan