Upgrading the Existing Facilities in Indian Railway Coache Review 11111

Embed Size (px)

Citation preview

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    1/26

    UPGRADING THE EXISTING

    FACILITIES IN INDIAN RAILWAYCOACHES.

    TEAM MEMBERS TEAM GUIDE

    Aiswarya.S.Rao Mrs. N.Deepa

    Harini .V

    Jerry Joseph

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    2/26

    INDIAN RAILWAYS

    Introduced in 1853.

    Undertaking of Govt. OfIndia, overseen by

    Ministry Of Railways. 4th largest railway network

    114,500 km of total track,7500 stations.

    Can carry 30 million passengers and 2.8million tons of freight daily.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    3/26

    ABSTRACT This project aims at improving the existing facilities in Indian

    railway coaches. The thrust areas being automatic temperaturecontrol inside the AC coaches and automatic toilet flushing

    system. For temperature control, the temperature inside the

    coach is compared with the outside temperature by using two

    temperature sensors and accordingly the temperatureadjustment will be done. If the temperature inside the coach is

    lesser than the outside temperature then the cooling will be

    decreased . And if the temperature inside the coach is higher

    than the outside temperature then the cooling will be

    increased. For the automatic flushing of toilets, we use an

    pressure sensor that will be placed on the toilet seat. When the

    pressure is sensed by the pressure sensor it will automatically

    initiate a flushing operation according to the PLC program.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    4/26

    EXISTING PROBLEMS

    Unhygienic conditions of

    the toilets. Manual temperature

    adjustment in ac coaches.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    5/26

    SOLUTIONS

    Automatic Flushing System

    in toilets to keep themclean.

    Automatic TemperatureControl in ac coaches.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    6/26

    AUTOMATICFLUSHING

    SYSTEM

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    7/26

    PROPOSED SYSTEM

    A pair of pressure sensors is placed

    above the toilet seat.

    When the pressure is sensed by the

    pressure sensor, a signal is generated

    which is given to the PLC using RF

    transmitter/receiver and this initiates

    the flushing.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    8/26

    COMPONENTS

    SOLENOID VALVE

    PLC

    PRESSURE SENSOR POWER SUPPLY

    DIODE IN4007

    TRANSISTOR BC547 RELAY COIL

    HT-12E/HT-12D TRASMITTER /RECEIVER PAIR

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    9/26

    BLOCK DIAGRAM

    Transmitter

    Encoder

    Pressuresensor

    Receiver

    Decoder

    Transmitter

    Encoder

    Receiver

    Decoder

    PLCSolenoid

    valve

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    10/26

    ELECTRONIC

    CIRCUITS

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    11/26

    HT-12E TRANSMITTER -INPUT SIDE

    Pressure sensor

    Output

    5v Power supplyMANUAL

    FLUSH

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    12/26

    HT-12D RECEIVER-PLC

    INPUT

    PLC

    OUTPUT

    OUT

    Y0

    MANUAL

    FLUSH

    MANUAL

    FLUSH

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    13/26

    HT-12E TRANSMITTER-PLC

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    14/26

    HT-12D RECEIVER-OUTPUT

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    15/26

    ELECTR0NIC CIRCUIT

    Relaycoil

    Protection

    diode

    Sv

    Input

    +12v

    NO

    COMSolenoid

    valve

    NC

    Transistor

    Relay

    contacts

    0V

    1K

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    16/26

    LADDER LOGIC

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    17/26

    AUTOMATIC

    TEMPERATURECONTROL

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    18/26

    EXISTING SYSTEM

    Three temperature settings are

    available in ac coaches , for

    adjustment of which an attendanthas to be called always. The

    adjustment is done manually.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    19/26

    PROPOSED SYSTEM

    The Temperature adjustment is done

    automatically by comparison of two

    temperatures - inside and outside. Initially the temperature inside the coach

    is lesser than the outside temperature. If

    outside temperature increases then thecooling increases and vice versa.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    20/26

    TEMPERATURE RANGES

    Lower Medium High

    Cooling 22 deg.C 24 deg.C 26 deg.C

    Heating 17deg.C 19 deg.C 21 deg.C

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    21/26

    COMPONENTS

    LM 35

    PLC

    POWER SUPPLY FAN

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    22/26

    BLOCK DIAGRAM

    Input

    Output

    PLCPc

    Inner temp

    sensor

    Outer temp

    sensor5v dc supply 5v dc supply

    output output

    cooler/fan

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    23/26

    LM 35

    IC Sensor

    Electrical voltage as output proportional to

    temperature ino

    C. Temperature Range: -55 to 150 o C.

    Sensitivity : 10 mV/o C.

    Supply Voltage : 5V Output Voltage : +6V to -1V

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    24/26

    LM-35

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    25/26

    WHY LM-35?

    More accurate than thermistor.

    Sensor circuit is sealed and not subjected

    to oxidation. Higher output voltage than

    thermocouple

    Amplification of output voltage not

    required.

  • 8/3/2019 Upgrading the Existing Facilities in Indian Railway Coache Review 11111

    26/26

    Have a clean and comfortable

    journey